| Sl. No. | Item Description |
| 1 | Earth work excavation for foundationby Mechanical means for Isolated & Combined Footing etcin all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by thedepartmental officers with an initial lead of 100 mts and clearing and levelling including dressing of sides and raming of bottoms etc., complete complying with standard specification and as directedbythedepartmental officers. |
| 2 | Upto 2.40m Footing Depth. |
| 3 | Earth work Open excavation by Mechanical Means for Open Earthwork in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by thedepartmental officers with an initial lead of 100 mts and clearing and levelling including dressing of sides and raming of bottoms etc., complete complying with standard specification and as directedbythedepartmental officers. |
| 4 | Upto 2.40mDepth. |
| 5 | Cement Concrete 1:5:10 (One Cement, Five crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jellyfor foundationincluding dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and including curing etc. complete complying with standard specification and as directed by the departmental officers -Mixing by mechanicalmeans |
| 6 | Supplying and filling in Foundation, Basement, etc with filling crushed stone sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. |
| 7 | Supply and filling in foundation and basement with Gravel with a lead of 0 - 72km in layers of not more than 15cm.thick well rammed watered and compacted with surface vibrator, watered and consolidatedetc. complete complying with standard specification and as directedbythedepartmental officers. |
| 8 | RefillingwithExcavated Earthother thansandwithan initial head load of 100 mts. and depositing the earth as shown by the departmental officers in layers of not more than 15cm thick well rammed with surface vibrator, watered and consolidatedetc., complete complying with standard specification and as directed by the departmental officers. |
| 9 | Providing ANTI-TERMITE treatment to soil adjacent under building foundation, plinth periphery of the building by applcation of chemicals of ISI 6313-1981 part I to IV in stages to suit the progress of work as per the detailed specification (Measurements taken for the plinthe area for the purpose of payment) including breaking of termite mounds, making holes with clow bar, closing the holes after the treatment and incliding cost of chemicals, labour charges, transport and storing etc., complete complying with the standard specification and as directed by the departmental officers. |
| 10 | Stage.I. spraying anti- termite treatement chemicals solution for foundation concrete surface laying the foundation concrete bottom and sides of the foundation.Stage.II. Spraying anti-termite chemical solution to the grade beam level, spraying for the grade beams, brick, masonry in superstructure in contact with the back fill earth. Stage.III. Spraying anti-termite treatment, chemicals solution on sand for the flooring before laying the flooring zone, Treatment has tobe carried out by making crow bar holes at an interval of 12\" to a depth of 8\" on the sand filling in basement and after levelling operation is over.Stage.IV. Spraying anti-termite treatment chemicals solution around the building (out side) by making crow bar holes at an interval of 12\" to a depth of 8\" in the periphery of building and chemical poured inside the holes and closed after the treatement. |
| 11 | Damp proof course as per IS 3067:1988 with Cement Mortar 1:4 (One Cement and Four crushed stone sand) 12mm thick mixed with best approved quality Integral liquid water proofing compound conforming to Indian Standard specification as specified by the departmental officers at 2% by weight of cement used , finishing and curing etc. complete complying with standard specification - Machine Mixing |
| 12 | Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, Sill slabs etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid with silver oakjoists of size 10cm x 5cm& 7.5cm x 5cm as support runner , vertical stiffener , side support and Top Horizontal stiffener spaced at about 60cm to 90cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid). |
| 13 | Supplying and erecting centering for plane surfaces such as RCC Floor Slab, Roof Slab, Loft, Landing Slabs, etc with necessary supports and strutting upto 3.60m height in all floors with all cross bracings using MS Sheets made of 10 gauge thick welded with MS angle of Size 25mm x 25mm x 3mm for boarding laid over steel adjustable span of size 2m x 2m (expandable upto 3.60m) and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick) , etc complete complying with standard specifications. Steel adjustable span and Steel Adjustable telescopic props shall be provided as directed by the departmental Officers.(Payment for centering shall be given after the concrete is laid). |
| 14 | Supplying and erecting centering for plane surfaces such as RCC Floor/Roof Beam, Lintels, Cantilever Beams, Bed Blocks etc.. with necessary supports and strutting upto 3.60m height in all floors with all cross bracings using MS Sheets made of 10 gauge thick welded with MS angle of Size 25mm x 25mm x 3mm for boarding laid over Steel adjustable Span of Size 2m x 2m(expandable upto 3.60m) and Silver Oak Joists of Size 10 x 5 cm spaced at 50cm to 60cm c/c and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick) Spaced at not more than 50 to 60cm c/c , etc complete complying with standard specifications. Steel adjustable span and Steel Adjustable telescopic props shall be provided as directed by the departmental Officers. (Payment for centering shall be given after the concrete is laid). |
| 15 | Supplying and erecting steel centering including necessary supportsFor plane surfaces such asrectangular or square RCC columns etc. which require only nominal strutting using mild steel sheets made of 10 gauge thick welded with MS angle size 40mm x 40mm x 5 mm and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick).etc..complete in all floors complying with standard specifcation. Steel Adjustable telescopic props shall be provided as directed by the departmental Officers. (Payment for centering shall be given after the concrete is laid). |
| 16 | Providing and laying in position, standardised concrete Mix M-20 Gradeby insitu machine mix concrete adopting weighing batch method in accordance with IS 456 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m) 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials). |
| 17 | For Foundation & Basement |
| 18 | For Superstructure in Ground Floor |
| 19 | For Superstructure in First Floor |
| 20 | For Superstructure in Second Floor |
| 21 | Cement Concrete 1:3:6 (One Cement, Three crushed stone sand and Six broken stone jelly) using 20mm size hard broken stone jellyfor dummy columns,etc., excluding cost of centering shuttering reinforcement grills and fabrication charges but including Cost of Mortar Plasticizer, curing etc. complete and as directed by the departmental officers.(Dummy columns should be at least 1 metre height)-Mixing by mechanicalmeans. |
| 22 | For Superstructure in First Floor |
| 23 | For Superstructure in Second Floor |
| 24 | Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel reinforcement grills of all variety like HYSD/CTD/TMTand all grade like Fe 500, Fe550D, Fe 500 D etc., for all RCC works as per design given including cost of steel reinforcement and G.I. binding wire, wastage etc. complete complying with standard specification and as directed by the departmental officers.(Contractor has to make his own arrangements for the supply of steel reinforcement and binding wire) |
| 25 | For Foundation & Basement |
| 26 | For Superstructure in Ground Floor |
| 27 | For Superstructure in First Floor |
| 28 | For Superstructure in Second Floor |
| 29 | Brick work in Cement Mortar 1:5 ( One Cement and Five CS Sand) using best quality Fly ash Brick of size230x110x70mm withclass designation of 7.5 conforming to IS 13757-1993 or IS 12894-2002 for foundation and basement including Cost of Mortar Plasticizer, curing, etc., complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally. other type of bond shall be done as directed by the Executive Engineer in charge. |
| 30 | For Foundation & Basement |
| 31 | Brick work inCement Mortar 1:6 ( One Cement and Six CS Sand) using best quality Fly ash Brick of size230x110x70mm withclass designation of 7.5 conforming to IS 13757-1993 or IS 12894-2002 for foundation and basement including Cost of Mortar Plasticizer, curing, etc., complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally. other type of bond shall be done as directed by the Executive Engineer in charge. |
| 32 | For Superstructure in Ground Floor |
| 33 | For Superstructure in First Floor |
| 34 | Brick work inCement Mortar 1:3 ( One Cement and Three CS Sand) using best quality Fly ash Brick of size230x110x70mm withclass designation of 7.5 conforming to IS 13757-1993 or IS 12894-2002 for foundation and basement including Cost of Mortar Plasticizer, curing, etc., complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally. other type of bond shall be done as directed by the Executive Engineer in charge. |
| 35 | For Foundation & Basement |
| 36 | Brick partition walls of 11.50cm thickness using best quality Fly ash Brick of size 230x110x75mm withclass designation of 7.5 conforming to IS 13757-1993 or IS 12894-2002 in Cement Mortar 1:3 (One Cement and Three CS Sand) using hoop iron reinforcement if found necessary including Cost of Mortar Plasticizer, curing etc.complete complying with standard specification and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately) |
| 37 | For Foundation & Basement |
| 38 | For Superstructure in Ground Floor |
| 39 | For Superstructure in First Floor |
| 40 | Cement Concrete 1:5:10 (One cement, Five crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken jelly for flooring including laying,consolidating, finishing, rendering the top surface rough to receive the floor, curing, etc. complete complying with standard specification and as directed by the departmental officers. (The rate is inclusive of necessary planking for panellingwherever necessary and as directed by the departmental officers -Mixing by mechanicalmeans |
| 41 | Paving the floor with best quality VitrifiedTiles of 600x600x8mm size and variety conformingIS 15622 with water absorbtion less than 0.08%of approved colour and shade laid over cement mortar bed of 20mm thick in cement mortar 1:3 (one cement and three crushed stone sand) with required Cement Slurry and Mortar Plasticizer in all floors and the top pointed with Water Resistant Tile Epoxy Grout etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) |
| 42 | Dadooing walls with Ceramic Tiles of size 300 x 450 x 8mm best approved quality, white / colour glazed tiles conforming to IS 15622 of following sizes in Cement Mortar 1:2 (One Cement and Two crushed stone sand),10 thickwith Mortar Plasticizer and pointing the joints with Water Resistant Tile Epoxy Groutat the rate of 0.27 Kg. / sq.m. neatly in all floors, curing, etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by Executive Engineer before use on works) |
| 43 | Flooring with Self Designed Colour Ceramic Tiles of size 305 x 305 x 6mm size and varietyconforming to IS 15622laid over cement mortar bed of 20 mm thick in cement mortar 1:3 (One Cement and Three crushed stone Sand) with required Cement Slurry and Mortar Plasticizer including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with Water Resistant Tile Epoxy Groutat the rate of 0.27 Kg. / sq.m. etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by Executive Engineer before use on works) |
| 44 | Paving the floor with Pre-Polished Concrete Anti-Skid Tiles (Required shape and design) of 20mm thick of approved quality and colour laid in accordance with IS 1443 over a cement mortar bed of 20mm thick in Cement Mortar 1:3 (One Cement and Three crushed stone sand) with required Cement Slurry and Mortar Plasticizerand pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by Executive Engineer before use on works) |
| 45 | Paving the floor with Pre-Polished Concrete Anti-Skid Step Tiles (Required shape and design) of 20mm thick of approved quality and colour laid in accordance with IS 1443 in Cement Mortar 1:3 (One Cement and Three crushed stone sand), with required Cement Slurry and Mortar Plasticizer,20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by Executive Engineer before use on works) |
| 46 | Providing Granolithic Floor Finish of the 25mm thick with plain cement concrete1:2:4(OneCement,Two Crushed Stone Sand and Four aggregate) using 6 to12mm gauge hard broken stone jelly including laying, finishing and the top rubbed smooth with power trowel, thread lining, curing etc. complete complying with standard specification and as directed by the departmental officers. (The rate is inclusive of necessary planking for panelling wherever necessary and as directed by the departmental officers) |
| 47 | Plain Cement Concrete 1:2:4 (one cement, two crushed stone sand and four hard broken stone jelly) using 20mm jelly for wearing coat includinglaying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers.-Mixing by mechanicalmeans. |
| 48 | Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no crushed stone sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers. |
| 49 | For Superstructure in Ground Floor |
| 50 | For Superstructure in First Floor |
| 51 | Finishing the top of roof with one course of machine pressed tiles of 230mm x 230mm x 16 mm to 18mm size of approved quality set in Cement Mortar 1:3 (One Cement and Three Crushed stoneSand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers |
| 52 | Supplying and fixing in position best approved of BIS quality PVC rain water down fall pipes of 110mm dia having a pressure of 4 kg. / sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of \"U\" clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification and as directed by the departmental officers. |
| 53 | ONE FLOOR |
| 54 | TWO FLOOR |
| 55 | Supplying and fixing Mild Steel grills for windows, ventilators etc.,complete complying with standard specifications and as directed by the departmental officers. |
| 56 | Supplying and fixing of Hollow pressed steel door frames for single leaf and double leaved door using pressed steel frame of size 105x60mm using mild sheet of 1.25mm thick (18gauge) special profile extruded section.The pressed steel frame shouldbe as per IS4351/1976.The rate in inclusive of hold fasts and provision to aldrop, tower bolt, hinges and lock plate etc,with one coat of zinc chnomate yellow primer and filling the inside hallow portion with cement concrete 1:2:4 using 20mm HBG stone jelly etc,complete complying with standard specificationand as directed by the departmental officers. |
| 57 | Supplying and fixing solid core flush shutter of Teak ply on both side with teak wook lipping alround 35 mm thick with necessary T.W. internal lipping alround conforming to IS 2202-1(1999) including cost of wind appliances and furniture fittings such as 3 Nos SS 304 Grade Butt Hinges of size (125mm x 30mm) , 2 Nos .300x12mm aluminium tower bolt 1 No. 200x12mm aluminium tower bolts 1no. 250x16mm aluminium aldrops, 2 nos. 200mm ‘D’ type aluminium door handle and door stopper with bush etc., complete complying with standard specification and as directed by the departmental officers - (Single leaf). |
| 58 | Supply and fixing of Solid PVC Door Shutters using 19 Gauge 19mm MS square tubes for styles and outer frames. 15mm MS square tubes for top, lock and bottom rails. The steel tubes shall be covered with 5mm thick solid PVC Sheets. Shutter using 5mm thick solid PVC Sheets for panelling shall rigidly fixed in position including necessary furniture and fittings. The over all size of styles shall be 50mm x 30mm. The over all size of top rail, lock rail and bottom rail shall be 75mm x 30mm. The over all size of frames shall be 50mm x 45mm with suitable rabate for housing the shutter (Soild PVC door with Frame). |
| 59 | UPVC Window Specification:Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work |
| 60 | upplying and fixing in position Glazed steel ventilator with Side/Central hung shutters( Two Leaves) frames and made shutter frame made out of steel section conforming to IS 7452 /1990.The outer frame made out of z section (F7D) of size 33 x22 x3 mm conforming to IS 7452/1990.The mullions are made out of (F4B) section of size 46x25x3 mm and conforming to IS7452/1990.The shutters are individual and each of them can be operated separately.Sash bars are made of T section (T2) of size 25 x 22 x 3mm 2 nos of sturdy hinges and one number of handle cum latch of special type are fixed are each openable shutter withsuitable opening in left for its easy operation, one member ofadjustable strings with fixing brackets of sufficient length are provided for each shutter 4 nos of40 x 40 x 3 mmangle hold fast 200mm length are welded with the frame at appropriate point M.S Square bars of 12 mm dia is weldedto the inner face of the ventilator at equal intervals not exceeding 10 cm spacing 3mm pin headed glass is used for Glazing with good quality anf fixed with 15 x 12 mm teak wood beadings with screws for fixing .The shutters are to open outside. All the section are given with one coat of red oxide primeretc., complete complying with standard specification.The sample of materials and fittings shall be got approved by the departmental officers before use on work.The rate shall inclusive of cost all materials labour charges one coat of primer,weld charges, including cost of welding electrodes,transportation to site work, loading,unloading and incidental charges etc., complete complying with standard specification and as directed by the departmental officers. |
| 61 | Supplying and fixing in position Steel Balustrades using 20mm square rods spaced at 150mm centre to centre so that the two balustrades in each step shall be placed centrally and the top of balustrades connected with the hand rails (cost of hand rail shall be measured and paid separately) by means of MS flats of size 40mm x 6mm in the groove 40mm x 6mm provided at the bottom of hand rail; the bottom of balustrades shall be fixed on to the top of step concrete.An additional MS flat of size 50mm x 6mm shall be provided at the centre of balustrades connecting all square rods to the entire length including cost of square rods, flat and applying one coat of red oxide primer to the iron surfaces, etc., complete complying with standard specification and as directed by the departmental officers. |
| 62 | Supplying and fixing 40mm dia GI pipe for staircase hand rail including labour charges for cutting, welding and fixing with MS flats (excluding cost of flat), etc., as directed by the departmental officers |
| 63 | Plastering with Cement Mortar 1:5 (One cement and Five Plastering sand), 12mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used, curing etc. complete complying with standard specification and as directed by the departmental officers. |
| 64 | Plastering with Cement Mortar 1:5 (One Cement and Five Fine sand), 20 mm thick on external surfaces of all floors in two coats in accordance with IS 1661:1972. The base coat shall be provided with 12mm thickand the top coat shall be provided with 8mm thick. The cost inclusive of cost of all material, Labours involved in all floors, mortar plasticizer at 200ml per 50 kg of cement used, curing etc., complete complying with standard specification and as directed by the department officers |
| 65 | Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three Plastering Sand) 10mm thick including mortar plasticizer at 200ml per 50Kg of cement used , hacking the surfaces and curing, etc., in all floors complying with standard specification and as directed by the departmental officers |
| 66 | Plastering the surface of walls with Cement Mortar 1:3 (One cement and Three plastering sand), 12mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used, curing etc., complete complying with standard specification and as directed by the departmental officers. |
| 67 | Painting two coats of newly plastered wall surface with Ready Mixed Plastic Emulsion Paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification and as directed by the departmental officers. |
| 68 | Painting the wall two coats with approved Weather Proof Exterior Emulsion paint over one primer coat on cement plastered wall surface ect., completecomplying with standard specification and as directed by the departmental officers. |
| 69 | Painting New Iron Works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) |
| 70 | Painting New Wood work with two finishing coats of synthetic enamel ready mixed paint of approved quality and colour over one coat priming coat in all floors including the cost of primer etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) |
| 71 | Manufacturing, supplying and fixing Precast Reinforced Cement Concrete slabs of following thickness in RCC 1:2:4 (one cement, two crushed stone sand and four aggregates), using following HBGS jelly excluding cost of reinforcement steel in position but including cost of moulding charges, casting of slab, finishing, curing and fixing in position in all floors etc., complete complying with standard specification and as directed by the departmental officers. |
| 72 | 50mm thick slab (using 20mm HBGS Jelly) |
| 73 | Supplying, laying and jointing UPVC pipes of Class 5(having working pressure of 10 kg/sq.cm) conforming to IS 4985- 2000of approved quality and best variety of the following dia including cutting,and fixing UPVC specials using UPVC adhesives (but excluding cost of such specials) in accordance with IS 7634-3(2003) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications.The UPVC pipes shall be got approved by Executive Engineer before use on works. - Internal water supply - above ground level.(SCHEDULE-40).INTERNAL WATER SUPPLY |
| 74 | 25mm dia |
| 75 | 20mm dia |
| 76 | Supplying, laying and jointing UPVC pipes of Class 5(having working pressure of 10 kg/sq.cm) conforming to IS 4985- 2000 of approved quality and best variety of the following dia including cutting and fixing UPVC specials using UPVC adhesives (but excluding cost of such specials) in accordance with IS 7634-3 (2003) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications.The PVC pipes shall be got approved by Executive Engineer before use on works - External water supply above ground level / Below ground level. (SCHEDULE-40)EXTERNAL WATER SUPPLY-ABOVE GROUND LEVEL |
| 77 | 40mm dia |
| 78 | 32mm dia |
| 79 | 25mm dia |
| 80 | Supplying, laying and jointing UPVC pipes of Class 5(having working pressure of 10 kg/sq.cm) conforming to IS 4985- 2000 of approved quality and best variety of the following dia including cutting and fixing UPVC specials using UPVC adhesives (but excluding cost of such specials) in accordance with IS 7634-3 (2003) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications.The PVC pipes shall be got approved by Executive Engineer before use on works - External water supply above ground level / Below ground level. (SCHEDULE-40)EXTERNAL WATER SUPPLY-BELOW GROUND LEVEL |
| 81 | 40mm dia |
| 82 | 32mm dia |
| 83 | Supplying UPVC Specials in water supply arrangements (both in internal and external water supply arrangements |
| 84 | 32mm dia UNION |
| 85 | 25mm dia UNION |
| 86 | 40mm dia ELBOW |
| 87 | 32mm dia ELBOW |
| 88 | 25mm dia ELBOW |
| 89 | 20mm dia ELBOW |
| 90 | 40mm dia COUPLING |
| 91 | 32mm dia COUPLING |
| 92 | 25mm dia COUPLING |
| 93 | 20mm dia COUPLING |
| 94 | 32mm dia TEE |
| 95 | 25mm dia TEE |
| 96 | 20mm dia TEE |
| 97 | 32x25mm dia REDUCER TEE |
| 98 | 25x20mm dia REDUCER TEE |
| 99 | 20x15mm dia REDUCER TEE |
| 100 | 32x25mm dia REDUCER ELBOW |
| 101 | 25x20mm dia REDUCER ELBOW |
| 102 | 20x15mm dia REDUCER ELBOW |
| 103 | 32x25mm dia REDUCER |
| 104 | 25x20mm dia REDUCER |
| 105 | 20x15mm dia REDUCER |
| 106 | Supplying and fixing in position first quality and approved variety of Gun metal Gate Valve / Wheel Valve with BIS make of the following dia including cost of shellac, thread balls, etc., complete complying with standard specifications (for both internal and external water supply arrangements).The valves to be used on work shall be got approved by the Executive Engineer before use on work. |
| 107 | 40mm dia GUN METAL WHEEL VALVE |
| 108 | 32mm dia GUN METAL WHEEL VALVE |
| 109 | Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications.(The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level |
| 110 | 110mm dia |
| 111 | 75mm dia |
| 112 | Supplying and fixing in position PVC specials of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to the walls and giving connection to the PVC soil stacks, dismantling the masonry or RCC works and re-doing the dismantled portion to original condition etc., complete complying with standard specifications. (The PVC specials should be got approved by the Executive Engineer before use on works). |
| 113 | 110mm dia DOOR ELBOW |
| 114 | 75mm dia DOOR ELBOW |
| 115 | 110mm dia TEE |
| 116 | 75mm dia TEE |
| 117 | 110mm dia BEND |
| 118 | 75mm dia BEND |
| 119 | Supplying and fixing in position White Glazed European Water Closet of best quality and approved make with 100 mm “P” or “S” trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, ouble flapped rigid PVC black seat and seat cover with CP brass hinges ncluding cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVCcapacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings such as 15mm brass ball valve with polythene float with brass handle, union, coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings such as 15mm brass connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe including cost of 600mm length of 110mm dia PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition etc. complete complying with standard specifications. (The EWC and flushing tank wiht all accessories should be got approved by the Executive Enginer before use on works) |
| 120 | White glazed European Water Closet with 10 litre capacity PVC flushing tank fixed on to wall |
| 121 | Supplying and fixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm white glazed earthern ware of approved quality and brand with \"P\" or \"S\" trap conforming to BIS with crushed stone sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two crushed stone sandand Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to CI soil pipes (including the cost of 100mm dia CI pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers.(The water closet should be got approved by the Executive Engineer before use on works). |
| 122 | Supplying and fixing in position best quality and approved make Indian made white / colour glazed earthernware wash hand basin of size 550 x 400mm (without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia \"B\" class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works). |
| 123 | Supplying and fixing position CI Nahani Trap / Floor Trap of the 75x50mm sizes with best stainless steel gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of crushed stone sandand five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three sand) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving connection to the CI / PVC pipes, etc., complete complying with standard specification. (The Nahani Trap should be got approved by the Executive Engineer before use on works) |
| 124 | Supplying and fixing in position 15mm dia brass CP screw down tap(heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary.(Taps should be got approved by the Executive Engineer before use on the works) |
| 125 | Supplying and fixing best approved best quality brass CP soap tray of size 150 x 100mm including cost of teak wood plugs, brass screws, etc., complete complying with standard specifications.(The soap tray should be got approved by Executive Engineer before use on works). |
| 126 | Supplying and fixing approved best quality brass CP towel rail 600mm long and 20mm dia with brackets of same materials including cost of teak wood plugs and CP screws, etc., complete complying with standard specifications. (The tower rail should be got approved by Executive Engineer before use on works). |
| 127 | Supplying and fixing in position Indian make bevelled edge mirror of approved quality and brand PVC / Fibre Glass framed 600x450x5.5mm thick mirror of following size , Shelf type with hard board backing of approved colour fixed with brass screws, rawl plug, etc., complete complying with standard specification. (The mirror should be got approved by the Executive Engineer before use on woks) Size :600 x 450 mm / 500 x 400mm / 1000 x 780 mm. |
| 128 | Supplying and fixing of PVC ready made WATER TANK of1000 Litre capacity of best and approved quality with ISI specification and having inlet,outlet, overflow and clearing pipe arrangements and labour charges for fixing in position with all necessary accessories and transporting at site of work including necessary brick work conveyance loading, unloading labour for fixing etc., complete complying as directed by the departmental officers. |
| 129 | Supplying and fixing in position CI manhole covers with CI frames (Heavy duty) of size 60cm x 60cm of best approved quality as per standard specification etc., complete compying with standard specifications |
| 130 | Supplying and fixing three phase capacitor type 1.00 HPmonoblock motor with suitable for 220 V 50 HZ, AC electrical supply with 1420 / 1440 RPM Motor of best quality and make with ISI mark on a suitable pedastal with foundation bolt and nut with panel board with accessories such as 1 No. 15 Amps DPIC switch, 1 No. DOL starter, 1 No. Ammeter 0 to 30 Amps with control switch, 1 No. Volt meter 0 to 500 V with control switch, 3 Nos. Indicator lamps with 5 Amps control switch, 1 No. 15 Amps Fuse carrier with necessary labour for fixing the pump and giving electrical wiring connections.The rate includes supplying and fixing of 1 No. of foot valvePump set including wiring from panel board to motor, etc., complete (The pump should be tested for a minimum of three days at contractor\"s own cost). |
| 131 | Supplying, laying and jointing glazed stoneware pipes of following dia of approved best quality with spigot and socket ends (in reverse direction) in dry condition and laid in loose joints (i.e.) without cement and spun yarn, so that the waste water can be drained to the trenches already available, excluding cost of earth work excavation, cost of re-filling with crushed stone sand/ earth, but including laying the pipe in true alignment and gradient and conducting required water supply test for draining with necessary tools and plants, etc., complete complying with standard specifications.(Earth work excavation, re-filling with excavated earth will be measured and paid separately). |
| 132 | 100mm dia |
| 133 | Supplying and filling 40mm guauge HBGS stone jelly for dispersion trench including loading conveying and unloading and as directed by the departmental officers etc. complete complying with standard specification. |
| 134 | Supplying and filling 20mm guauge HBGS stone jelly for dispersion trench including loading conveying and unloading and as directed by the departmental officers etc. complete complying with standard specification. |
| 135 | GST @ 18% |