}

Refurbishment Of Happy Valley Quarters, Including Construction Of Roof Truss, Plumbing And Bathroom Refurbishment And Electrical Wiring Related Works Under Darjeeling Division, Wbsedcl, siliguri-West Bengal

West Bengal State Electricity Distribution Company Limited has published Refurbishment Of Happy Valley Quarters, Including Construction Of Roof Truss, Plumbing And Bathroom Refurbishment And Electrical Wiring Related Works Under Darjeeling Division, Wbsedcl. Submission Date for this Tender is 24-06-2025. Shed Construction Tenders in siliguri West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

49590375
Refurbishment Of Happy Valley Quarters, Including Construction Of Roof Truss, Plumbing And Bathroom Refurbishment And Electrical Wiring Related Works Under Darjeeling Division, Wbsedcl
Tender
Indian
West Bengal
Siliguri
24-06-2025

Tender Documents

Tender Details

Refurbishment of Happy Valley Quarters, including construction of Roof Truss, Plumbing and bathroom refurbishment and electrical wiring related works under Darjeeling Division, WBSEDCL- 1 Civil WorksEarth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm. 2 Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)(a) With earth obtained from excavation of foundation 3 Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. 4 Cement concrete with 30mm down graded shingles excluding shuttering. N.B. Variety. a) In ground floor (1:3:6) proportion. 5 Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, as per relevant IS codes.In Ground Floor: 6 In First Floor 7 In Second Floor 8 Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. (ii ) River BazreeIn Ground Floor: 9 In First Floor 10 In Second Floor 11 Brick work with 1st class bricks in cement mortar(1:4). a) In foundation and plinth. 12 b) In Super structure, ground floor 13 b) In Super structure, first floor 14 b) In Super structure, second floor 15 125mm tick brick work with 1st class bricks in Cement mortar (1:4) . a)In ground floor. 16 Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.(a) For works in foundation and upto roof of ground floor/upto 4 m(i) Tor steel/Mild SteelI. SAIL/ TATA/RINLIn Ground Floor: 17 i) 25mm to 30mm thick shuttering without staging in foundation etc.In Ground Floor: 18 M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc.I) For structural members of specified sections weighing less than 22.5 Kg./mIn Ground Floor: 19 In Second Floor 20 In Third Floor 21 M.S. structural works with hollow sections (square or rectangular shape) conforming to IS: 806-1968 & IS:1161-1998) connected to one another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete.i) For roof truss worksa) Span up to 12 MtrIn Ground Floor 22 In First Floor 23 In Second Floor 24 M.S. works in framed gratings of window etc.made of round or square bars and frame work or M.S. flats (with the bars securely fixed to the flat bar frame) with or without intermediate flat bar stiffener and fixed with necessary screws etc. complete, as directed. In Ground floor. 25 In First Floor 26 In Second Floor 27 Stripping off worn out plaster and raking out joints of walls, celings etc. upto any height and in any floor including removing rubbish within a lead of 75m as directed 28 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface](ii) With 1:4 cement mortar20 mm thick plasterIn Ground Floor: 29 In First Floor 30 In Second Floor 31 15 mm thick plaster 32 In First Floor 33 In Second Floor 34 10 mm thick plaster 35 In First Floor 36 In Second Floor 37 (a) Applying 2 coats of bonding agent with synthetic multi functional rubber emulsion having adhesive and water proofing properties by mixing with water in proportion (1 bonding agent : 4 water : 6 cement) as per Manufacturers specification [Cement to be supplied by the Department] 38 Applying epoxy mortar ( 10 mm nominal thick) over leached, honey combed and spalled concrete surface and exposed steel reinforcement complete as per Technical specification 39 Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m. 40 Dismantling all types of masonry excepting plain cement concrete of reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75m. a) In ground floor including roof 41 Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75m. In ground floor including roofa) Upto 150 mm thick. 42 Dismantling R.C. floor, beams etc including cutting rods and removing rubbish as directed within a lead of 75m including stacking steel bars. In ground floor including roof 43 Removal of rubbish, earth etc from the work site and disposed of the same beyond the compound in conformity with The Municipal Corporation rules for such disposal loading into the truckand cleaning the site in all respects as per direction of E.I.C. 44 Extra cost of labour for prefinished and premoulded Nosingto treads of steps, railing, window sill etc. 45 Supplying, fitting & fixing granite slabs 15mm to 18 mm. thick with uniform texture & without decorative veins in columns, wall, facia etc. with 15 mm thick [avg] cement mortar (1:2) including making suitable arrangements to hold the stones properly by brass / copper hooks including pointing in cement mortar (1:2) (1 white cement : 2 marble dust) with admixture of pigment matching the stone shades all complete as per direction of the Engineer-in-charge including cost of all materials, labours, scaffolding, staging ,curing and roughening of concrete surface complete. Area of each Granite slab > 0.6 upto 1.0 square metre.[Using cement slurry at back side of granite @ 4.4 kg/sq.m &white cement slurry for joint filling @ 1.8 kg/sq.m]In Ground Floor 46 In First Floor 47 In Second Floor 48 Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(A) FloorWith Polymerised Adhesive and Epoxy grout pointingincluding spacer- 2 mm ( When Tiles are laid over existinghard ready surface)(b) Area of each tile above 0.09 Sq.m [using adhesive 4.5 mmthick](i) Coloured decorative 49 In First Floor 50 In Second Floor 51 (A) WallWith Polymerised Adhesive and Epoxy grout pointingincluding spacer- 2 mm ( When Tiles are laid over existinghard ready surface)(b) Area of each tile above 0.09 Sq.m [using adhesive 4.5 mmthick](i) Coloured decorative 52 In First Floor 53 In Second Floor 54 Removing old scales, blisters etc. of interior surface of walls,ceiling by scraping etc. and preparing smooth and even surface with rendering or cement mortar (1:2) (as necessary), to make the surface suitable for receiving distemper. (Payment against this item will be made only when this has been done on the specific direction of the Engineer-in-charge). 55 Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturers specification) including cleaning and smoothning of surface.Two Coats 56 Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturers specification and as per direction of the EIC.(a) One CoatIn Ground Floor: 57 In First Floor 58 In Second Floor 59 Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturers specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer(Two Coat)Premium 100% Acrylic EmulsionIn Ground floor 60 In First Floor 61 In Second Floor 62 Removing old paint from blistered painted surface of steel or other metal by chipping including scraping and cleaning and exposing the original surface. 63 (a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc 64 Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. 65 Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : On steel or other metal surface :With super gloss (hi-gloss) -(iii) Two coats (with any shade except white) 66 (a) On timber or plastered surface :With super gloss (hi-gloss) -Two coats (with any shade except white) 67 Supplying, fitting & fixing single skin color coated trapezoidal profile for wall cladding, Roof shall be made of 0.45 mm BMT (Base metal Thickness) 0.50 mm TCT (Total Coated Thickness excluding paint), G550 (min 550 yield strength of Zincallume metallic coating (IS 15965) with high Solar Reflectance Index (SRI) value for better cooling as per thermatech technology, 1000-1015 mm effective cover width with five major corrugation, 28mm high rib spaced at 203mm c/c with subtle square fluting in the pan and the end rib shall have anti-capillary groove and return leg. The steel sheet shall be fastened with 40 micron Zinc coated or 25 micron Zinc-tin alloy coated , hex head, self-drilling screw as per IS 3566-2002 Class 3 fastener. The base steel shall be coated with Zinc-Aluminium alloy Zincalume (AZ150)(i.e. 55% Alu, 43.4% Zn, 1.6% Si) minimum of 150 GSM coating total on both sides, pre-painted with colorbond XRW (xterior roofing, walling) paint system of 35 micron Super Durable Polyster Paint (SDP)with stable inorganic pigment with no lead contents confirming IS15965, The sheet shall be free from defects and have brand marking of manufacturer giving product details on the back of the sheet at regular interval confirming genuinity of the material.(i) In roof (a) With 0.50 mm thick sheet 68 Galvanised iron sheet ridging fitted with necessary bolts, screws, washers etc complete.(225mm end lapping)(A) 300 mm lapping each way(b) With 0.63 mm sheet 69 Supply, fitting & fixing uPVC rain gutterof approved make (Brand: Aquastar or Similar quality) having 160 mm width, outlet dia of 90mm minimum, including uPVC fittings, clamps/bent etc. as per manufacturer specification including cost of labour for fitting and fixing, tools etc. complete in all respect. 70 Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps Sal : Siliguri. 71 Panel shutters of door and window, as per design (each panel consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings.(iv) 25mm thick shutters with 12mm thick panel of size 30 to 45 cm.(c) Other Local Wood. In Ground floor 72 In First Floor 73 In Second Floor 74 Providing & fixing factory made 30 mm thick factory made solid pvc door shuttermade out of single piece extruded solid pvc profile . The style & rails shall be of size of 75 x 30 mm having wall thickness of 5 mm. The style and top bottom rail shall have one side a thickness of 15 mm integrally extruded on the hinge side of the profile for better screw holding power. 15 mm thickness shall be of single piece extruded solid pvc profile whereas it shall be not be made of sheet pasted profile) . The styles and rails shall be reinforced with MS tube of size 18 mm(±) 1mm x 18 mm (±) 1mm x 1mm painted with primer all four corners of reinforcement to be welded or sealed . solid pvc extruded bidding (push fit type) will be set inside the styles and rails with a cavity to receive single piece extruded 5 mm pvc sheet as panel. The styles and rails will be metered cut and join with the help of pvc solvent cement, self tapping screw and braket of size 200 x 75 mm /welded at each corner. Single piece extruded solid pvc lockrail of size 100 x 30 mm with a wall thickness 5 mm & 15 mm integrally extruded in the middle of lockrail & fixed with styles with the help of PVC solvent cement & self driven self tapping screws of size 100mm x 8mm complete as per manufacturers specifications and direction of Engineer-in-Charge. b) Factory made Single piece extruded PVC profiles door shutter of both side laminated wood grains decorative Finish: 75 Supplying, fitting & fixing factory made foam PVC (density shall not be less than 600 kg/cum) door frame (finished weight of 2.73 kg/mtr.) of size 100mm X 45mm made off with 5mm thick extruded foam PVC sheet, mitre cut at junction of horizontal and vertical member and joined them by heat welding. Entire door frame profiles to be reinforced with steel primer coated 19 SWG 40mm X 20mm M.S. tube. An additional 5mm thick PVC sheet with desired colour/shade to be provided at the exposed surface and three nos 5mm thick PVC sheet to be provided as gap insert. The door frame to be fixed with wall by using 8mm dia. and 100mm long strainless steel screws and PVC fasteners. A minimum of 4 nos. screws to be provided for each vertical member & 2 nos. for horizontal member all complete as per direction of Engineer-in-Charge. (b) Pre-laminated Colour. 76 Supplying best Indian sheet glass panes set in putty and fitted and fixed with nails and putty complete. (In all floors for internal wall & upto 6 m height for external wall)(i) 3 mm thick (weighing 7.4 kg/Sq.m) 77 Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws:(iii) 100mm long x 10mm dia. bolt. 78 Anodised aluminium butt hinges of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 205/66) and fitted and fixed with cadmium plated screws:(iii) 75 x 45 x 2.5mm. 79 Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete: (a) With continuous plate base (Hexagonal/ Round rod)(ii) 100 mm grip x 10 mm dia rod. 80 i) Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting.(b) 250mm long. 81 Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately) (b) 40mm X 6mm, 200mm Length 82 ii) Godrej Hydraulic door closer fitted and fixed complete. (b) Medium type 83 Door stopper (Anodised aluminium) 84 Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - InCharge.(A) In 10-12 Micron thickness Annodizing filmI) Natural whitea) 2- track sliding windowi) Bottom frame 85 ii) Top and side frame 86 b) 3- track sliding windowi) Bottom frame 87 ii) Top and side frame 88 d) Shutter for all track sliding window.i) Bottom & Top member 89 ii) Style side member 90 iii) Interlock member 91 g) Fixed glazing.i) Top, bottom and side member 92 ii) Mullion 93 iii) Glazing clip 94 h) Louvered windowi) Top, bottom and side member 95 ii) Louvered Section. 96 iii) Cleat angle ( Non-annodized) 97 Labour charge for fabrication and installation of composite door, window, partitions made from annodized extruded alloy aluminium sections for the following units:-(A) Glazed aluminium sliding windows made of extruded and annodized alloy aluminium sectios, fabrications, including cutting to proper shape and size, drilling and aligning of window shutter frame fitted with in built locking arrangements, sliding rollers and other necessary fittings, fixture, adhesives and joineries along with extruded neoprine or EPDM gasketing in between window frame and masonry work (walls, column, beam.lintels etc.) as well as between glass and shutter frame for fixing glass and Polysulphide sealant and in between shutter and window frame where necessary including cutting to requisite size and fixing glass as per drawing, specification and direction of EIC. The rate includes the hire charge of all tools and plants, including all incidental charges, adhesive, joineries such as screw, cleat angle etc. but excluding the cost of extruded aluminium sections, glass, neoprene / EPDM gasket, locking arrangement and rollers.i ) 2 track sliding window 98 ii ) 3 /4 track sliding window. 99 iv ) Fixed glazing 100 v ) Louvered window 101 Supplying PVC rollers for sliding windows as per direction of Engineer in charge. 102 Supplying maruti lock (100mm) 103 Supplying EPDM gusket of approved make and brand as per direction of Engineer in charge.i) For sliding windowsa) T shaped EPDM gasket for frames. 104 b) U shaped EPDM gasket for frames. 105 Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987.i) 4mm thick clear glass. 106 ii) 4mm thick coloured / tinted / smoke glass. 107 Supplying, fitting and fixing 10 litre porcelain low-down cistern of approved make with either side or bottom inlet, side overflow, brackets complete with all internnal PVC fittings. White 108 Supplying, fitting and fixing E.W.C. in white glazed vitreous chinaware of approved make complete in position with necessary bolts, nuts etc.(a) With P trap 109 Supplying, fitting and fixing Closet seat of approved make with lid and C.P. hinges, rubber buffer and brass screws complete.(a) E.W.C(ii) Plastic (hallow type) white 110 Supplying, fitting and fixing stainless steel sink complete with waste fittings and two coats of painting of C.I. brackets(a) Sink only(i) 530 mm X 430 mm x 180 mm 111 Supplying,fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia. (ii) 450 mm long 112 Supplying,fitting and fixing approved brand 32 mm dia.P.V.C. waste pipe, with PVC coupling at one end fitted with necessary clamps.(i) 600 mm long 113 Supplying, fitting and fixing Waste fittings complete. (b) Polythene(i) 32 mm 114 Supplying, fitting and fixing pillar cock of approved make.a) (i) CP Pillar Cock - 15 mm. (Equivalent to Code No. 507 & Model - Tropical / Sumthing Special of ESSCO or similar brand). 115 Supplying, fitting and fixing C.P. Wall Flange 116 Supplying, fitting and fixing Orissa pattern water closet in white glazed vitreous chinaware of approved make in position complete excluding P or S trap (excluding cost of concrete for fixing).(i) 580 mm X 440 mm 117 Wash basin vitreous china of approved make (without fittings) supplied,fitted and fixed in position on 75mm X 75 mm X 75 mm wood blocks and C.I. brackets including two coats of painting of C.I. brackets.(ii) 550 mm X 400 mm size 118 Constructing Inspection pit of insidemeasurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling, 15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials.ii) With Bazree (N.B Variety) (Other than SAIL/TATA/RINL) 119 Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately)a) For Exposed Work PVC Pipes15 mm 120 20 mm 121 25 mm 122 40 mm 123 Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made foraccesories, specials. (b) For Concealed Work (i) CPVC Pipes Class-1,SDR-1115 mm 124 20 mm 125 Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete.A) UPVC Pipes:(ii) 110 mm. Dia. 126 Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992(A) (i) Single Socketed 3 Meter Length(b) 110 mm 127 (c) 160 mm 128 Coupler/Plain Tee (b) 110 mm 129 (c)160 mm 130 v) Plain Y (b) 110 mm 131 x) Bend 87.5º (b) 110 mm 132 (c) 160 mm 133 xv) Vent Cowl (b) 110 mm 134 xvi) Pipe Clip(b) 110 mm 135 Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineerin-charge. (Payment will be made on centre line measurement of the total pipeline including specials. (A) Above ground(ii) 110 mm dia. 136 (B) Under ground(ii) 110 mm dia. 137 (iii) 160 mm dia. 138 Taking out rain water down pipe. 139 Supplying, fitting and fixing bib cock or stop cock.(a) (i) Chromium plated Bib Cock short body (Equivalent to Code No. 511 & Model - Tropical / Sumthing Special of ESSCO or similar brand). 140 (e) PTMT (Polytetra Bib Cock / Stop Cock ( Prayag or equivalent) 15 mm 141 (b) (i) Chromium plated Stop Cock (Equivalent to Code No. 513(A) & 513(B) & Model - Tropical / Sumthing Special of ESSCO or similar 142 (f) Hand Shower(Health Faucet) with 1mtr Fexible Tube with Wall Hook(Equivalent to Code No.573 & Model -ALLIED of Jaquar or similar). 143 Labour for punching hole in plastic water storage tank upto 50 mm dia. 144 Supply of Chlorinated Polyvinyl Chloride (CPVC) pipes& fittings conforming to IS-15778: 2007Ball Valve15 mm 145 Ball Valve20 mm 146 Ball Valve25 mm 147 Ball Valve32 mm 148 Ball Valve40 mm 149 Electrical WorksRemoval and opening of old and damaged wiring at the staff quarter and Divisional Office premises and making the surface ready for new wiring where required. 150 Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire for ECC, incl. necy. fittings etc. to light/fan/call bell point with Modular type switch (Brand approved by EIC) fixed on Modular GI / PVC switch board with top cover plate on wall incl. mending good damages to original finish. [PVC casingcapping and Switch board both on surface]Average run 6 mtr 151 Average run 9 mtr 152 Average run 12 mtr 153 Distribution Wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire for ECC, incl. necy. fittings etc. with S & F 6A 5 pin Modular type plug socket and switch (Brand approved by EIC) fixed on 4 Module GI / PVC switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works [PVC casing-capping and plug box both on surface]On Board 154 Average run 4.5 mtr 155 Wiring in 1.1 KV grade single core stranded FR PVC insulated & unsheathed copper wire (Brand approved by EIC) of following sizes in 25mm PVC casing-capping (Precision make) incl. necy. PVC clips, fittings etc.2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) 156 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) 157 2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) 158 Supplying and fixing PVC casing-capping [Precision Make] on wall or ceiling, incl. necy. PVC fittings etc. and mending good damages to building works.20x10mm Size 159 25x10mm Size 160 Supply & Fixing 240 V 16 A Piano key type switch (Brand approved by EIC) on GI Modular type switch board having top cover plate and making necessary connections as required 161 Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. 162 Supply & Fixing 240 V, 6 A, 3 pin Modular type plug socket (Brand approved by EIC) with 6A Modular type switch, without plug top on 4 Module GI Modular type switch board with 3 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. 163 Supply & Fixing 240 V 6 A Modular type switch (Brand approved by EIC) on existing GI Modular type switch board having top cover plate and making necessary connections as required 164 Supply, delivery Fixingtwin LED tube light(2X18/20)W(suspended bellow Fan level or extra the ceiling) with 2 No. 20 mm dia EI conduit (14 SWG) supports incl. S&F EI conduit, ball socket/socket type ceiling plate and connecting the length of PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm) flexible copper wire of 1.10mt. length. (Make- phillips, Havells, Bajaj) 165 Supply, delivery Fixingsingle LED tube light(18/20)W fitting complete with all accessories directly on wall/ceiling with HW block and ceiling plates, nipples etc. as required (Make- phillips/ Havells/ Bajaj) 166 Supply and delivery of 2 x 2 LED Commercial Light 28W to 36W with all necessary fittings (Philips/Havells/Crompton/Bajaj) 167 Supplying Exhaust fan (300mm).Havells Ventilator DB Neo 168 Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter: 30 Cm or (12) 169 Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building worksa) 4 Module 170 b) 6 Module 171 c) 8 Module 172 d) 12 Module 173 Supplying & Fixing GI Modular Switch Board of the following sizes complete with top cover plate flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building worksa) 2 Module 174 Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachmenta) 4 way 175 b) 8 Way 176 Supply & Fixing 240/415V, 63 A, TPN MCB OF Breaking Capacity 10 KA & C characterstic on din rail of exsting DB & necessary connection(Legrand) 177 Supplying and fixing Sheet steel Main Switches on angle iron frame on wall [60/63 A] 178 Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. [2 + 8 Way] 179 Supply & Fixing 240/415V, 6-32 A, SP MCB OF Breaking Capacity 10 KA & C characterstic on din rail of exsting DB & necessary connection(Legrand) 180 Earthing with Copper plate (610x610x3mm size) having weight of 9.84 Kg and 1 No. 25x5mm Copper strip (3.20 mt long) & 1 no. 6 sqmm PVC insulated stranded Copper wire (4 Mt long) incl. S & F 15 mm dia GI pipe (ISI-Medium) protection (4 mt. long) to be fillied with bitumen, partly under the ground level & partly above ground level to an average depth of 3.65 Mts. below the ground level and restoring the surface duly rammed incl. providing 3.0 mt long, 25 mm dia GI pipe (ISI-Medium) for periodic treatment, incl. providing masonery enclosure on the top of the earth electrode of overall size 86.36x86.36x46cm deep(below Ground level) complete with cemented brick work (1:6) of 25 cm width, duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56x35.56cm with locking arrangement, GI reducer and treatment of soil by using salt & charcoal or coke for plate electrode 181 Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 40 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required 182 Connecting the equipment to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages (a) Stranded GI wire(i) 7/16 SWG 183 Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board 184 Suplying, Fabrication, installation and commissioning of outdoor type feeder pillar box (Main Panel Board) with MS angle/flat iron and MS Plate frame with water proofing enclose mounted on ground in CC foundations (1:3:6) and providing anti corrosive painting, including supplying and fixing of the following itemsa) Indication Lampb) Main Switchesc) Ammeterd) Voltmetere) Fusesf) Other Necessary items as required

Key Value

Document Fees
Refer document
EMD
INR 71875.0 /-
Tender Value
INR 35.93 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail