}

Tender For The Work Under Deposit Scheme In Area Of Electricity Urban Distribution Division-Sri Gorakhnath, Gorakhpur (Running Tender) - Loading, Unloading And Safe Carriage Of Following Materials From Store Centre, Gorakhpur To Je Dump Store And Je Dump , Gorakhpur-Uttar Pradesh

Purvanchal Vidyut Vitaran Nigam Limited has published Tender For The Work Under Deposit Scheme In Area Of Electricity Urban Distribution Division-Sri Gorakhnath, Gorakhpur (Running Tender) - Loading, Unloading And Safe Carriage Of Following Materials From Store Centre, Gorakhpur To Je Dump Store And Je Dump . Submission Date for this Tender is 21-06-2025. Transformer Supply Tenders in Gorakhpur Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

49581090
Tender For The Work Under Deposit Scheme In Area Of Electricity Urban Distribution Division-Sri Gorakhnath, Gorakhpur (Running Tender) - Loading, Unloading And Safe Carriage Of Following Materials From Store Centre, Gorakhpur To Je Dump Store And Je Dump
Tender
Indian
Uttar Pradesh
Gorakhpur
21-06-2025

Tender Documents

Tender Details

Tender For The Work Under Deposit Scheme In Area Of Electricity Urban Distribution Division-Sri Gorakhnath, Gorakhpur (Running Tender) - Loading, unloading and safe carriage of following materials from Store Centre, Gorakhpur to JE dump Store and JE dump Store to work site with proper stacking :- 2 11 KV CTPT Pole mounting unit 3 11 KV Electronic TVM Meter 4 11 KV PPMC 5 11/0.4 KV 250 KVA Transformer 6 11/0.4 KV 400 KVA Transformer 7 11 KV XLPE Cable 3X185 sq mm 8 11 KV XLPE Cable 3X120 sq mm 9 11 KV XLPE Cable 3X70 sq mm 10 I/D & O/D C/J Kits suitable for 3X70 sq mm XLPE Cable 11 Straight Through suitable for 3X70 sq mm XLPE cable 12 I/D & O/D C/J Kits suitable for 3X120 sq mm XLPE Cable 13 Straight Through suitable for 3X120 sq mm XLPE cable 14 I/D & O/D C/J Kits suitable for 3X185 sq mm XLPE Cable 15 Straight Through suitable for 3X185 sq mm XLPE cable 16 11/0.4 KV 25 KVA Transformer 17 11/0.4 KV 63 KVA Transformer 18 11/0.4 KV 100 KVA Transformer 19 S.T Pole 11 mtr. long 20 S.T Pole 9 mtr. long 21 PCC 8.5 mtr long 22 ACSR Dog conductor 23 ACSR Weasel conductor 24 LT AB Cable (3X95+1X70+1X16) Sq.mm. 25 LT AB Cable (3X120+1X95+1X16) Sq.mm. 26 11 KV Pin insulator with Pin 27 11 KV Disc insultor with fitting 28 11 KV Dropper angle (100X50X2028 mm) 29 11 KV S/S Base angle 30 11 KV Top Channel 31 11 KV V Type Cross arm 32 11 KV D.O. Fuse set 33 11 KV TPMO with Polymer insulator 34 LT XLPE Al. 3.5X70 sq mm 35 LT XLPE Al. 3.5X150 sq mm 36 LT XLPE Al. 1X240 sq mm 37 LT Cable 1X400 sq mm 38 Stay set complete with 5 Kg wire 39 Earthing Complete 40 T-Off channel (125X65X1300) mm 41 Supply offollowing material/fitting complete in all respect :- 42 LT Distribution Box with Clamp 43 LT Shackle insulator 44 Stone Pad 300x300x75 mm 45 Danger Board with clamp 46 Number Plate 47 LT Clamps 48 Insulated Dead end clamp with I hook 49 Suspension clamp with I hook (Insulated) 50 LT insulated Piercing connector 51 LT PVC cable 1X35 Sq.mm. for energizing D.B. 52 F Bracket 53 Holding clamp with Nuts & Bolts 54 Al Lugs 70/150/240/400 sq mm 55 GI Nuts & Bolts of different sizes 56 Copper Z Clamps 57 HDPE Pipe dia 160 mm 58 G.I Pipe dia 6 inch 59 G.I Pipe dia 4 inch 60 The excavation of 2 No foundation pit of size 750mmX450mm and having depth of 1/6th of the full length of the pole. Fabrication & erection of double Pole with fixing of necessary clamps & accessories (Top Channel, Dropper Angle etc.) as per required. All required materials such as Holding clamp/STP clamp, Nuts & Bolts off size etc will be provided by the contractor.Grouting of Pole in cc 1:4:8 (Cement, sand & 40 mm brick ballast), Grouting will be done in the block ofsize 450x450 mm x depth upto ground level and backfilling of pits with mud completely and leveling etc (Material provided by Contractor).Making plinth around Pole height 300 mm above ground level with top 100 mm is kept tapered so that No rainwater gets accumulated on the top. All work will be done as per RESPO Norms & relevent IS Specification. 61 The excavation of 1 No foundation pit of size 750mmX450mm and having depth of 1/6th of the full length of the pole. Fabrication & erection of single Pole with fixing of necessary clamps & accessories (Top Channel, Dropper Angle etc.) as per required. All required materials such as Holding clamp/PCC clamp, Nuts & Bolts off size etc will be provided by the contractor.Grouting of Pole in cc 1:4:8 (Cement, sand & 40 mm brick ballast), Grouting will be done in the block ofsize 450x450 mm x depth upto ground level and backfilling of pits with mud completely and leveling etc (Material provided by Contractor).In case of STP Making plinth around Pole height 300 mm above ground level with top 100 mm is kept tapered so that No rainwater gets accumulated on the top. All work will be done as per RESPO Norms & relevent IS Specification. 62 Painting of Pole by double coating Aluminum & Red oxide paint. Paint will beprovided by contractor 63 Earthing of ST Pole by MS earthing Rod & 6 SWG earthing Wire as per RESPO Norms. 64 Fabrication, errection, commissioning & Testing of25/63/100/250/400 KVA T/F on Double Pole/Plinth with all accessories including make its LT and HT connection. All necessary materials such as Holding clamp, Al.Lugs (Confirming to IS 8309), Z Clamp, Nuts & Bolts will be supplied by the Contractor. 65 Erection and grouting of stay in CC ratio 1:4:8 of Cement, Sand and Stone Ballast including cost of grouting material with nozelling and binding of stay wire (Complete work) 66 Erection ofFuse Set 67 Erection ofTPMO 68 Laying, stringing, sagging, binding and jumpering of ACSR Dog/Weasel conductor for LT/HT Line with fixing of LT Clamps/other clamps, Shackle insulator and nuts&bolts off size as per required. 69 Chemical earthing of Transformer (Body+Neutral) as per IS Code 3043 - 1987 specification (Materials will be provided by contractor) (Compelete in One Job) 70 Laying, stringing, sagging, binding and jumpering of ABC Cable (Size may vary) of LT Line with fixing of Distribution Box with Clamp, Insulated Dead end clamp with I hook, Suspension clamp with I hook(Insulated), LT insulated Piercing connector, XLPE 1X35 Sq.mm. Al. cable for enerzing DB,XLPE 1X16 Sq.mm. 71 Hoisting & Looping of 11 KV XLPE Cable Providing GI Pipe 3 M Long with complete Work 72 Erection of 11 KV XLPE Cable Jointing Kit/Straight Through with complete work 73 Installation of PPMC & 11 KV CT/PT Pole Mounting Unit 74 Earthing of PPMC & CT/PT unit 75 Laying of HDPE Pipe 6 inch Diameter for laying of 11 KV XLPE Cable by horizontal drilling method. The HDPE pipe shall be of PE 80 grade with pressure rating PN6 conforming to IS 4984/1995 and shall have wall thickness of 6.20 to 7.10 mm (HDPE pipe 6 inch dia with elbow and socket for 11 KV cable will be supplied by contractor) 76 Laying and dressing of under ground 11 KV XLPE Cable(Size may vary) by Horizontal drilling method as per RESPO norms. The Depth of horizontal drilling shall be between 2 to 3 meters or as per site required. 77 Laying and dressing of under ground 11 KV XLPEby Digging method using sand & Bricks as per RESSPO norms. 78 Laying and sagging of overhead 11 KV XLPE Cable as per site required. 79 Dressing, Tagging and Safe Laying of 11 KV XLPE cable under Concrete roadside trench with necessary material. (All Necessary Materialsprovided by Contractor) 80 Construction of T/F plinth of size 2x2x1.2 mtr with the help of first class brick & 9 masonary in the ratio 1:4 cement & sand coarse. Filling the structure completely andplastering outer surface as per RESPO norms. Top of the plinth covered with 4 RCC Slab of ratio 1:1.5:3 (Cement, sand & concrete) grouting with 2 Nos. ISMC size 125X65X6 MM (confirming to IS 808:1989) of 2000 mm long for resting. All required materials will be provided by the contractor. 81 Grill fencing of 11/0.4 KV S/S shall be made of rectangular of size & height approx 2 meter as per site requirement with fabrication 50X50X5 mm angel the frame is also have 1 no. Horizontal runner of MS flat 40x5 welded in middle to support of grill, having a gate on road side must have provision of locking arrangement. The work is including painting of fencing as per norms. Work will be done as per RESPO specification. 82 Shifting of existing Transformer from its existing place to new site with complete work 83 Supply and Complete Installation of 2 Nos. Henley Type Tailless Unit 300 AMP in Box using LT XLPE 1X240 Sq.mm. Cable,LT Crimping Lug, GI Nuts & Bolts etc (as per site requirement) on 11/0.4 KV Distribution Transformer. (Only LT XLPE 1X240 Sq.mm. Cable will be provided by Department)Specification of Henley Type Tailless Unit 300 AMPdescribed as below-1. Henley Type MS Sheet duly painted grey enameled paint- MS of 18 SWG (54X4.5 inches) with holes as per requirement2. 6 No. Insulator- Made of White Glazed Porcelain3. 6 No. Copper Spring Contact- 32X3.7 mm Made of Copper4. 3 No. L Contact - Brass5. 3 No. Metal Part Connector For Holding Busbar- Brass6. 1 No. Casted Patti- M.S.7. 1 No. Neutral- Brass8. Iron Clip, Bolt, Nuts, Washer and Screw etc for Tightening- All Galvanized9. Copper Bus Bar Strip- 500X50X5 mm (3 Nos.Copper Busbar Strip to be used on 2 Nos. Tailless unit)10. Aluminium Bus Bar Strip- 500X50X5 mm (1 No)All work will be done as per RESSPO Norms & relevent IS Specification. 84 Supply, fabrication, erection of LT Pillar Box for Tailless Unit after making Plinth of Height 300 mm above ground level LT Pillar Box Size- 1650X1050X520 mm with Gate and Proper Locking arrangement (Canopy of 15 Degree), should be made of Galvanised steel sheet.All work will be done as per RESSPO Norms & relevent IS Specification. 85 Supply and complete installation of SMC Box of size 450x375x200 mm for 25 kVA to 100 kVA Transformer on Pole (Box made out of (Thermostate Plastic) Sheet Moulding Compound by the process of Hot Press Compression moulding confirming to IS: 13410, SMC base or Doors shall not soften or bend on Heating, Doors fitted to Base by concealed hinges, Thickness- 2mm, Tolerence : +/- 5%) including provision of LT Fuse Protection set suitable for Transformer (All material including Aluminium Lugs, Clamp, Nuts & Bolts etc shall be supplied by the contractor.) 86 Dismantling of following Line materials and safe loading, unloading and carraige of dismantled material from work site to departmental store 87 STP pole 11/9 meter long 88 11 kV Line 89 LT Three Phase Line

Key Value

Document Fees
INR 3540 /-
EMD
INR 25000.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail