| 1 | Lot-1: Singtam-1 THCC Schedule-1 |
| 2 | Conducting topographical surveys and ground profiling of the service area, including preparation of drawings, geotechnical investigations, civil/structural design and associated drawings, as well as electrical, mechanical, and instrumentation design and drawings. This also encompasses the creation of as-built drawings, validation of structural design by a reputable government institution (e.g., IIT/NIT or as approved by the Employer\"s Representative), comprehensive documentation, and execution of other tasks in accordance with technical specifications and the directives provided by the Employer\"s Representative. |
| 3 | Lot-1: Singtam-1 THCC Schedule-2: Other than Parking, Community & Commercial Centre, THCCs will be used as Emergency Relief Centres, THCC will also accommodate Toilets with EWCD features and have dedicated facility rooms for women. The areas are maked in drawing provided in Volume IV. |
| 4 | Preparatory Works: Clearing grass and removal of the rubbish upto a distance of 50m outside the periphery of the area cleared. |
| 5 | Earth Work: Excavation in hilly area in ordinary rock not requiring blasting by mechanical means including cutting and trimming of slopes and disposal of cut material with all lift and lead upto 1000 metres. |
| 6 | Earth Work: Excavation in hilly areas in hard rock not requiring blasting, by Manual means including trimming of slopes and stacking of 60% of cut material with all lifts and lead upto 50 metres. |
| 7 | Carriage of Excavated Earth Cost of Haulage Excluding Loading & Unloading On Surface Road- For 20 KMs. |
| 8 | Filling Works: Providing and laying hand packed stone soling in buildings works with clean hard selected stones,all complete ( Manual Means). |
| 9 | Plain Cement Concrete: Providing and Laying in position cement concrete of specified grade including compacting curing etc all complete. 1:2:4. |
| 10 | Water Proofing: Providing integral water proofing compound in mixture of Cement Concrete/Reinforced Concrete/Cement Mortar @200ml per 50kg of cement in accordance to IS:2645 and IS:9103 standards for water proofing of concrete and sand cement mortar in the part/portion of structures subjected to ingress of water/moisture like basements, roofslabs, water tanks& water retaining structures, external plastering, bathroom sand balconies, sump sand drains etc(Dr fixit pidi proof LW+/ Perma Plast-O-Proof/ Endura E160/AquaplastWPL/WeberMixIL/equivalent) (ONLY FOR CAST IN SITU NOMINAL MIXES). |
| 11 | Reinforced Cement Concrete |
| 12 | Providing M-30 grade concrete instead of M-25 grade BMC/RMC.(Note:-CementcontentconsideredinM-30is@340kg/cum)For all Height. |
| 13 | Providing and Laying in position specified grade of reinforced cement concrete excluding the cost of form work,finishing and reinforcements. 1:1.5:3 Mix (1 cement, 1.5 coarse sand 3graded stone aggregate 20mm and down nominal gauge). |
| 14 | Smooth finishing of the exposed surface of R.C.C. work with 6 mm thick cement mortar 1:3 (1 Cement : 3 fine sand). |
| 15 | Form Work: Providing, fixing & removing form work for casting R.C.C items as indicated below: with imported timber from outside the state) |
| 16 | Beam, lintels, girders, brersumers and cantilevers. |
| 17 | Foundation, footings, base of column etc for mass concrete. |
| 18 | Wall. |
| 19 | Floor slab, roof slab, landing, balcony and access platform. |
| 20 | Square columns. |
| 21 | Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). Suspended floors, roofs, landing, beams and balconies (Plan area to be measured). |
| 22 | Reinforcement: Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 23 | Masanory Works |
| 24 | Providing and Laying first class brick work in one brick thick in super structure of standard size bricks with 1:5cement mortar(1 cement and 5 clean coarse sand)as per the direction of Engineer in Charge including curing etc all complete. |
| 25 | Providing and laying first class brickwork in half brick thick in super structure of standard size bricks with 1:4 cement mortar (1 cement and 4 coarse sand)including carriageofbricks up to work site, curing etc all complete. |
| 26 | Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. |
| 27 | Plastering |
| 28 | Providing and Laying 12mm thick cement plaster of specified mix in single coat including finishing even and smooth and curing complete. 1:4 mix. |
| 29 | Providing and Laying 15 mm thick cement plaster of specified mix in single coat including finishing even and smooth and curing complete. 1:4 mix. |
| 30 | Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. |
| 31 | Flooring |
| 32 | Providing and Laying flooring with granite marble stone slabs 20mm thick granite stone slabs flooring of size not less than 1.0 sqm of 20mm thick laid over 20mm (average) 1:4cm thick bare laid cement concrete and joint treated with white cement, mixed with matching pigment. |
| 33 | Providing and Laying white or colored glazed tiles of size 200mm x 300mm of plain/normal prints colours(white, grey, ivory, platinum, cream, glacier white,summers and, beach, wood duro, melody, or equivalent) in skirting, risers of steps and Dados on 12mm thick cement plaster (1cement, 3coarsed sand) 1:3 bare and jointed with white cement slurry. |
| 34 | Providing & Laying white or colored glazed vitrified tiles of Orient / Somani or equivalent colour in flooring,treads of steps landing etc laid on a bed of 15mm, cm 1:3 finishedwith white cement slurry. |
| 35 | Providing and Laying kota stone slabs 25mm thick in Risers of steps, skirting dado and walls laid on 12mmthick (average) thick base of c.m. 1:3(1cement,3coarsesand)and jointed with grey cement slurry mixed with pigments to match the shade of theslab including cutting, rubbing and polishing complete. |
| 36 | Extra for Nosing for Kota Stone For Treads. |
| 37 | Painting |
| 38 | Providing and distempering with oil bound washable acrylic distemper two or more coats of approved brand or manufacture over a coat of cement primer to give an even shade on new surface including preparation of surface etc complete. |
| 39 | Providing and painting with acrylic exterior paints of quality and make equivalent to EXCEL, WEATHER SHIELD to give an even shade including brushing the surface clean of dirt, dust etc and sand papering and filling the scratches complete on New surface. |
| 40 | Doors and Windows |
| 41 | Providing fitting and fixing water proof flush doors shutters, solid block hard core construction with frame of 1st class hard timber, with well matched 3mm commercial plyincluding hinges with screws complete.- 32mm. |
| 42 | Providing and fixing Piano hinges 35mm wide and 1mm thick with necessary screw etc complete. - M.S finished either with brass plating or nickel plating . |
| 43 | Providing,fitting and fixing .sliding door bolts with nuts and screws etc. complete.- Size 300x16mm -Brass (Chromium Plated). |
| 44 | Providing and fixing tower bolts 300x10mm (Barreltype) with necessary screws etc complete.- MS. |
| 45 | Providing fitting and fixing rolling shutters of approved make, made of required size MS laths interlocked together through their entire length and joined together at the end by end lock mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including providing and fixing wire springs grade No2 andMS top cover of required thickness of rolling shutters as per the direction of Engineer-in-Chargeall complete. |
| 46 | Providing and fixing glazing in Al .doors and windows ventilaor shutters and partitions etc. with PVC/neosprenegasket with CP brass/stainless steel screws etc. completeas per architectural drawings and direction of Engineer - in- Charge. |
| 47 | Providing and fixing anodized aluminum works for doors, windows, ventilators and partitions with extruded built up standard tubular or other section of approved make confirming IS733 and IS1285, fixed with rawl plugs and screwsfilling up the gaps at junctions, at top, bottom and sides with required PVC/neoprene felt,etc.Al.section shallbesmooth , rust free. |
| 48 | Water Supply and Sanitation |
| 49 | Providing, Fitting and fixing GI pipe (HEAVY DUTY), (excluding trenching, refilling, compacting and the cost of fittings) all complete - 80 mm dia G I pipe. |
| 50 | Providing, Fitting and fixing GI pipe (Medium Class), (excluding trenching, refilling, compacting and the cost of fittings) all complete - 15 mm dia G I pipe. |
| 51 | Providing,fittingandfixingwhitevitreouschinapedestal(Europeantype)watercloset(W.C pan with seat and lid, with C.P. brass hinges, 10ltr lowlevel cistern with fittings and brackets 40mm flush bend with specials,all complete: W.C.pan European Bidet sstandard CAT NO 30001. |
| 52 | Providing,fitting and fixing.white vitreous white chinawashflat backbasin with CI brackets,painted,15mm CP brass pillar taps, CP brass chain with rubberplug, 32mm CP brass wastepipe ,leador PVCconnection 32mm dia CPbrass capandunions, complete including cutting and making good thewalls wherever required. HINDWARE/Simpola or equivalent. One wash basin with one pillar cock 63x45CM. |
| 53 | Providing,fitting and fixing white vitreous china flat back or wall cornerty pelippedfront urinal basin of size 440x315x325mm with 5ltr automatic flushing cistern with C.I .brackets, GI flush pipe and spreaders with brass unions and G.I.clamps including cutting and making good the walls and floors as required all complete. |
| 54 | Providing, fitting and fixing soil, waste and vent pipes including testing etc complete. PRINCE / SUPREME or equivalent soil pipe. |
| 55 | 160mm Dia. |
| 56 | 100mm Dia. |
| 57 | Providing, Fitting and fixing Chromium plated fittings of approved quality and size complete: (ESCO ORIGINAL or Equivalent).BIB COCK -15mm Dia. |
| 58 | Providing and fitting chromium plated toilet paper holder including the making holes and fixed to timber cleats with CP screws washer etc. all complete. |
| 59 | Providing, fitting and fixing Beveled gauge mirror of superior glass with 6mm A.C. sheets ground and fixed to timber cleatswith CP screws, washer etc complete. |
| 60 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken 300 mm height including rounding of junctions of for final test.“All above operations to be done in order:With average thickness of 120 mm and minimumat khurra as 65 mm. |
| 61 | Miscellaneous |
| 62 | Providing Passenger Lifts with Power operated centre opening doors and AC Variable Voltage & Variable Frequency Control- Capacity of 16 persons and Travel Height upto G+8. |
| 63 | Providing Goods Lifts with Power operated centre opening doors and AC Variable Voltage & Variable Frequency Control- Capacity 3 Ton and Travel Height upto G+8. |
| 64 | Providing Fire Fighting System with wet rise and Sprinkler System and automatic Alarm System. |
| 65 | Providing box drain of30cm(ht)x45cm (width) internal dimension with 1:2:4 Plum concrete (20mm & down) inside walls thickness of 23cm (hillside) and 30cm (roadside) and 1:3:6 (20mm & down) base concrete of thickness of 15cm with standard specification over 15cm stone soling including providing & laying guard stones complete, as per the direction of the Eng. |
| 66 | Rain Water Harvesting. |
| 67 | Building Management Plan |
| 68 | Supplying, installation, testing and commissioning of IP Based CCTV system for building security comprising of PTZ Fixed camera, cabling, recording , display system and hard ware software support- for indoors only, CCTV coverage should be limited to 15%of total plinth Area. |
| 69 | For External surveillance- total Plot area- plinth area at ground level. |
| 70 | Providing and placing on terrace high density polyethylene water storage tank with man hole lid and suitable locking arrangement including making holes for inlet, outlet and ball cock including testing etc. all complete: (Sintex or equivalent)- 2000 Litre. |
| 71 | Supplying, installation, testing and commissioning of STP/ETP of appropriate technology including Civil Works (except plant room), Tertiary Treatment etc. for the Building/ campus. |
| 72 | Supplying, installation, testing and commissioning of LED Street/ Compound/ High mast/ Pathway/ Landscape Lighting for the entire Campus. (for Total plot Area) |
| 73 | Sensor based car parking system with controller, display etc. as required. (Cost based on minimum car quantity of cars). |
| 74 | Carriage & Haulage |
| 75 | Head load of stock materials for a distance beyond 30m and within 100m distance. |
| 76 | Head load of non-stock materials for a distance beyond 30m and within 100m distance. |
| 77 | Head load of stock materials for a distance beyond 100 m for every additional 1000 m. |
| 78 | Head load of non-stock materials for a distance beyond 100 m for every additional 1000 m. |
| 79 | Loading and Unloading of Stone Boulder/Stoneaggregates/Sand/Kanker/ Moorum. |
| 80 | Loading and Unloading of Cement or steel by Manual Means. |
| 81 | Cost of Haulage Excluding Loading and Unloading Surface Road. |
| 82 | Sand, Aggregate & Stone-60 Km |
| 83 | Cement, Steel-90 Km |
| 84 | Reinforcement |
| 85 | Apply thoroughly mixed Re Arm Bond 4031 adhesive on both the sides of the joint onto the well prepared substrate by using a suitable trowel. • If the concrete substrate is damp, work the adhesive well into the substrate with a brush. • The thickness of adhesive layer should not be less than 1mm – 1.5 mm and the bonding width on each side of the joint should be at least 50 mm BOTH SIDE on 15 cm wide tape (Gap size 50mm width), .• Fix the Seal Arm Tape TPE on the adhesive within the open time of the adhesive. • Press the tape firmly and without trapping air into the adhesive by using a suitable roller. • The adhesive should be squeezed out on both sides of the tape by ~ 5 mm. • The base layer of the Re Arm Bond 4031 Adhesive achieve initial set before the top layer is applied. |
| 86 | Providing and fixing 1mm thick & 400mm width aluminium strips over the treated area as per drawing.(For Vertical Areas). |
| 87 | Providing and fixing 2 mm thick 400mm width aluminium strips over the treated area as per drawing. (For Horizontal Areas). |
| 88 | Eco Screed (35-40mm) along with Lane Marking with Flo Arm Coat EC |
| 89 | Providing Screed Layer: 300 mlBONDING AGENT max. with 20 litres water in 50 kgs Ordinary Portland cements Grade 43/53. This covers approx. ≥ 25 m², depending on the porosity and other aspects of the substrate. |
| 90 | Providing Screed ECOcompatible with OPC 43 or 53 grade cements in accordance with IS8112. |
| 91 | Providing Lane Marking Primer |
| 92 | Providing lane marking Coat |
| 93 | Alluminium sheeting fixed with encapsulated lens type reflective sheeting including 2% toward slettering, cost of angle iron, cost of drilling holes, nuts, bolts etc. and signs as applicable. |
| 94 | Supplying, installation, testing and commissioning of LAN System comprising of Core switches & L2 switches with 10 G, 10 Giga SFP modules, WIFI Access points, WIFI controller, Network Management Software, Racks, CAT 6A cable, Patch Panels, OFC etc. Rates Applicable on Plinth Areaexcluding service/common Areas. |
| 95 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 96 | Supplying, fabricating, fitting and fixing steel tubular trusses including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, welded and bolted including special shape washer etc . |
| 97 | Providing, fitting, fixing of 24 BWG Pre-painted HULASsheet roofing with lapping of 150mm (two corrugation)with G.I. hooks, bolts and nut 8mm dia with bitumen, GI limpet washersincluding carriage all complete. |
| 98 | Providing and fixing 15cm wide 45cm overall semicircular Pre-painted HULAS. sheet (Class I) gutter with iron brackets 40x3mm size, bolts filled with epoxy etc including making, connection with rain water pipes. |
| 99 | Providing fitting fixing ridges or hips of 60cm overall width of plain 24BWG prepainted (HULLAS Sheet fixed with G.I, J or L hooks bolts & nuts 8mm dia filled withepoxy in each bolts (8to10 gm per bolt), Limpets, Bitumen washers etc. all complete. |
| 100 | Providing fitting and fixing 30cm deep 24 BWG Pre-painted HULAS sheet eaves board including (50x25mm)dressed sal timber beading and M.S. rod brackets all complete. |
| 101 | Demolition of Existing Buildings including stacking of servicable material and dispose dimolition waste up to 20 Kms |
| 102 | Supply , Installation and Commissioning of of Solar GIRTPV systemwith Solar PV modules, Solar Inverterincluding Cables, Earthing System,AL rail type MMS, IIP, etc.) |
| 103 | Providing Three Seater Waiting Area Chair set at Ground Floor. Material of Chair Should be Carbon Steel and Weight of one set Should be in between 325Kg to 350 Kg. Dimensions Should be : Length (70 inches), Width ( 23 inches), Height ( 31 inches);Color: Shining Silver. |
| 104 | Developing Green Wall (Vertical Garden) on Front and Both sides Elevation with PVC Components (Front Panel, Side Panel, Stablizers, Hanging Hook, Bottom Drainage Tray and Geo-Textile Pouch) Including Planting outdoor Plants Like Peperomia, Syngoniums, Philodendron, Epipremnum, Begonia, Anthuriums, Nephrolepis, Chlorophytum, Lantana, Pilea, Rheo discolor, Cuphea, Fittonia, Spathiphylum, Schefflera etc suited to the climate of Sikkim- For only Four Parking Floors |
| 105 | Providing Public Adress System of Bosch or Equivalent Make with Wireless Mike and 240w Amplfier |
| 106 | Providing Signages of 7mm Alluminium Plate of Size 12inchX 5 Inch on Each Floor |
| 107 | Providing, driving with hydraulic piling rigs with power units and installing driven cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of shoe and the length of pile to be embedded in the pile cap etc. all complete. (Length of pile for payment shall be measured from top of shoe to the bottom of pile cap) - 550mm Dia Pile |
| 108 | Providing 3 Sets of Two number PVC Dustbins (One Green & one Blue) having Capacity of 240 Litres each, at Each Floor |
| 109 | Providing and installing 1.5HP Water Pump having Maximum Discharge of 3360 LPM and Head upto 45 meters. Rated Voltage-220V and Rated Frequency 50 HZ (One working & one Standby) |
| 110 | Providing Oil & greese Trap for Storm water Drains |
| 111 | Providing Stainless steel commercial food waste disposer, fully digested with inbuilt shredder. No emission of harmful gases. No enzymes should be used- capacity-175Kg/day |
| 112 | Lot-1: Singtam-1 THCC Schedule-3 |
| 113 | INTERNAL WIRING |
| 114 | Wiring for light/Fan/Call bell & 6 A plug point with 2x1.5 sqmmFRLSHPVC insulated copper conductor single core cable in best quality recessed alkathine pipe and earthing the point with 1x 1.5 sqmmHR FRLS PVC insulated copper conductor single core cable as required. |
| 115 | Wiring for 16 A plug point with 2x 2.5 sqmmFRLSH PVC insulated copper conductor single core cable in best quality recessed alkathine pipeand earthing the point with 1x 2.5 sqmmFRLSH PVC insulated copper conductor single core cable as required. |
| 116 | Wiring for sub-main for light/fan/call bell & 6 amps plug points with 2x 2.5 sqmmFRLSH PVC insulated copper conductor single core cable in best quality recessed alkathine pipe and earthing the point with 1x2.5 sqmm FRLSH PVC insulated copper conductor single core cable as required. |
| 117 | Wiring for sub-main for 16 amps (2x1000W) plug points with 2x4.0 sqmm FRLSHPVC insulated copper conductor single core cable in best quality recessed alkathine pipeand earthing the point with 1x4.0 sqmm FRLSH PVC insulated copper conductor single core cable as required. |
| 118 | Wiring for sub-mainwith2x 6.0 sqmm FRLSHPVC insulated copper conductor single core cable in best quality recessed alkathine pipeand earthing the point with1x 6.0 sqmmFRLSH PVC insulated copper conductor single core cable as required. |
| 119 | Wiring for mainwith 2x 10.0 sqmm FRLSHPVC insulated copper conductor single core cable in best quality recessed alkathine pipeand earthing the point with 1x 10.0 sqmmFRLSH PVC insulated copper conductor single core cable as required. |
| 120 | SWITCH,SOCKET & ACCESSORIES: Supplying & fixing 06 amps 1 way FT switch on white moduler plate and metal flux box including connection etc. as required. |
| 121 | 4 no. 06 amps FT switch with 1 no white 4 moduler plate and 4 moduler metal flux box. |
| 122 | 6 no. 06 amps FT switch with 1 no white 6 moduler plate and 6 moduler metal flux box. |
| 123 | 8 no. 06 amps FT switch with 1 no white 8 moduler plate and 8 moduler metal flux box. |
| 124 | Supplying & fixing 1 no. 16 amps socket, & 16 amps switch,white plate (4 module) & Metal flux box (4 module)includingconnection etc. as required. |
| 125 | Supplying & fixing 1 no. 06 amps socket with 1no. 06 amps switch, 1 no. 3 module white plate & 1 no. 3 module metal flux box ) including connection etc. as required. |
| 126 | Supplying & fixing 1 no. fan step regulator 120 watts, 1 no. white plate (2 module) and 1 no. (2 module) metal flux box including connection etc. as required. |
| 127 | LIGHT FITTINGS |
| 128 | 20watts Sleek surface Down light slim profile surface mounted down light |
| 129 | LED tube light cadila plus 20 watt |
| 130 | 6 watt LED up-down hexa/penta/round/square accent lightning. |
| 131 | LED Flood Light 60 watt |
| 132 | LED 15 watt Pyramid square |
| 133 | Ceiling Fan 1200mm48\" (Havells/USHA) Conforming to IS: 374 |
| 134 | Ventilating fans 300mm 12\" (Havells) |
| 135 | Heavy duty Exhaust Fan 12\" (Havells) |
| 136 | DISTRIBUTION SYSTEM |
| 137 | Miniature Circuit breakers (MCB) Single pole 240V6 - 32 Amps |
| 138 | Miniature Circuit breakers (MCB)Four pole 40 Amps |
| 139 | Miniature Circuit breakers (MCB)Four pole 63Amps |
| 140 | MCB DB (Triple pole & neutral) Double door6way |
| 141 | MCB DB (Triple pole & neutral) Double door8way |
| 142 | MCB DB (Triple pole & neutral) Double door12way |
| 143 | Safe earthing T-19 model 50 mm diameter x 2 mtrs. Electrode (Copper bonded) & One bag backfill chemical compound. |
| 144 | Copper strips 25mm X 5mm from Cu. plate earth electrode |
| 145 | Alkathene pipe 1/2\", 3/4\", 5/8\"&1\" (Bardia) |
| 146 | PVC Tape |
| 147 | L.T DISTRIBUTION LINE |
| 148 | L.T distribution switch board with copper bus bar, out-door type Kiosk, having electrolytic annealed copper bus bar 50x12mm for phase & 50x6mm for neutral circuits mounted on glazed porcelain or Bakelite base & fitted with voltmeter, ammeter, selector switches for ammeter & voltmeter, electronic KWH meter, indicating lamps cabin light, fabricated with 12 gauge M.S plain sheet, painted with anti- rust primer & two coats of Epoxy paint of shade 631 as per IS: 8623-1, front opening doors with gasket & locking arrangement complete with following incoming & outgoing controls:INCOMING:1 No. 100 A, 4P,50KA, MCCBOUTGOING: 3 Nos. 63A FP MCCB, 35 KA, & 1 No. 32A FP MCCB, 35 KA all with built in Thermo Magnetic Release. |
| 149 | L.T distribution switch board with copper bus bar, out-door type Kiosk, having electrolytic annealed copper bus bar 50x12mm for phase & 50x6mm for neutral circuits mounted on glazed porcelain or Bakelite base & fitted with voltmeter, ammeter, selector switches for ammeter & voltmeter, electronic KWH meter, indicating lamps cabin light, fabricated with 12 gauge M.S plain sheet, painted with anti- rust primer & two coats of Epoxy paint of shade 631 as per IS: 8623-1, front opening doors with gasket & locking arrangement complete with following incoming & outgoing controls:INCOMING:1 No. 63 A, 4P,50KA, MCCBOUTGOING:OUTGOING: 2 Nos. 40A FP MCCB, 35 KA, & 1 No. 32A FP MCCB, 35 KA all with built in Thermo Magnetic Release. |
| 150 | 3.5 core 95 sqmm 1.1 KV XLPE Insulated Heavy Duty Power Cable for working voltage upto & Including 660/1100 Volts Armoured Aluminium conductor.(Havells make or equivalent) |
| 151 | 3.5 core 35 sqmm 1.1 KV XLPE Insulated Heavy Duty Power Cable for working voltage upto & Including 660/1100 Volts Armoured Aluminium conductor.(Havells make or equivalent) |
| 152 | CF54/100GC Cable Tray GC (Hot dip) |
| 153 | Coupler for jointing two cable trays (coupling kit ) |
| 154 | Cablofil bolt cutter |
| 155 | L.T. 1.1 KV heat shrinkable outdoor End Termination Kit for 3.5 X 95 sqmm PVC/XLPE cables 2,3 & 1/2 core conforming to IS:13573 (Dension or equivalent) |
| 156 | L.T. 1.1 KV heat shrinkable outdoor End Termination Kit for 3.5 X 35sqmm PVC/XLPE cables 2,3 & 1/2 core conforming to IS:13573 (Dension or equivalent) |
| 157 | Safe earthing T-19 model 50 mm diameter x 2 mtrs. Electrode (Copper bonded) & Onebag backfill chemical compound. |
| 158 | Copper strips 25mm X 5mm from Cu. plate earth electrode |
| 159 | Alkathene pipe 1/2\", 3/4\", 5/8\"&1\" (Bardia) |
| 160 | STREET LIGHTS |
| 161 | 8.5 Mtrs. Long 410-SP-18 swaged type steel tubular pole with CI base plate & cap, double part ( Nuts & bolts type) working load 120 Kgs |
| 162 | 2 Core x 16 sqmm 1.1KV PVC/XLPE heavy duty power cable for working voltage upto & including 660/1100 volts Aluminium armoured conductor. |
| 163 | 2.5 sqmm. ISI markedSingle core PVC insulatedindustrial Gradecopper conductor flexible cable, 1100volt |
| 164 | 2\" dia flexible super PVC green pipe 3.5kg/cm2 |
| 165 | 72Watt LED Street light fittings conforming to IS:16101 |
| 166 | Polycarbonate junction box with bus bar arrangement and 6 Amp MCB (Street lights) |
| 167 | Miniature Circuit breakers (MCB)Double pole 40 Amps |
| 168 | Astro time switch |
| 169 | Safe earthing model T-19, short time current 20 ka rms for 1 sec (LV/MV) application, 50 mm dia x 2 mtrs electrode & one bag fill chemical compound). |
| 170 | Copper wire 6/8 SWG for earth looping system |
| 171 | Alkathine pipe 1\" |
| 172 | Aluminum thimblebullet 16sqmm |
| 173 | Red Oxide Metal Primer (Nerolac or Equivalent) conforming to IS: 2074 |
| 174 | Aluminum Paint (Nerolac or Equivalent) conforming to IS: 2339 |
| 175 | Concreting of 8.5 Mtrs. Swaged Steel Tubular Pole in 1:4:8 cc in 0.9x0.9x1.50 mtrs Pit, Construction of parapet 0.35 x 0.47x0.153 mtrs. In 1:3:6 cc i/c 12mm cement plaster of parapet in 1:4 Mix. |
| 176 | Excavation of 0.45x0.90x1.00mtrs. Cable trench in mix soil & re-filling with available excavated earth & providing cement concrete on the top of the trench. |
| 177 | Supply, Installation, testing & commisioning of 500KVA DG sets,AMF Panel, bus ducting/Cables from DG set to essential panel, DG set enclouser room sound insulation/ventilation/smoke exhaust as required,earthing of DG Set system,control cabeling,fuel tank/piping, DG set exhasut piping/exhaust chimney as per CPCB norms. Civil works connected with DG set including foundation as required PAR CPWD 2021 , ITEM NO. 6.3.1 |
| 178 | EXTERNAL ELECTRIFICATION: INSTALLATION OF 630 KVA DISTRIBUTION TRANSFORMER. |
| 179 | 11 Mtrs steel lattice structure of 65x65x6 mm M.S. angle complete with nuts & bolts (without arms) |
| 180 | M.S.channel ISLC 75(75x40x6mm) X 2.8mtr. for supporting line, G.O.S & D.O fuse etc(SAIL Brand) |
| 181 | M.S angle 50x50x6 mm for holding the MS Channel |
| 182 | M.S.bolts & nuts 16mm dia x 40 mm length full thread. |
| 183 | 50 HZ , DYN 11,3 phase , ONAN cooled , outdoor type 500 Kva , 11/0.433 KV, copper wound distribution transformer with off-circuit tapping +2.5%, +5% , on H.V side with bare bushing on HV & LV side &provided with standard fittings and accessories with first filling of transformer oil conforming to IS: 1180(PART -I) 2014: Energy efficiency level 2 |
| 184 | 3C X 70 sq mm11 KV ( Uo) / 11 KV(U) XPLE Insulated armoured cable with aluminium conductor conforming to IS:7098 PART-2 |
| 185 | Heat Shrinkable outdoor type end termination kit 3 C X 70 sqmm EPKT 3352 for 6.35 Kv/11 Kv (U) 3 core XLPE (Kit no. EOKT 3332-3382) Raychem make or equivalent |
| 186 | 1.1 Kv PVC / XLPE insulated heavy duty power cables 3.5 core X 400 sqmm for working conforming to IS: 7098 Part -I |
| 187 | L.T. 1.1 KV heat shrinkable outdoor End Termination Kit for 3.5 X 400 sqmm PVC/XLPE cables 2,3 & 1/2 core conforming to IS:13573 (Dension or equivalent) |
| 188 | 800A L.T. Distribution switch board with copper bus bar, outdoor type Kiosk,having electrolytic annealed copper bus bar 50 X 12mm for phase & 50 X 6 mm for neutral circuits mounted on glazed porcelain or Bakelite base & fitted with voltmeter, ammeter, selector switches for ammeter & voltmeter, electronic KWH meter, indicating lamps cabin light, fabricated with 12 guage M.S. plain sheet , painted with anti-rust primer & two coats of epoxy paint of shade 631 as per IS: 8623-1, front opening doors with gasket & locking arrangement complete with following incoming & outgoing controls. INCOMING:1 No. 800 A, 4P,50KA, MDO ACB.OUTGOING: 4 Nos. 200A TP MCCB , 50 KA, 1 No. 63 A TP MCCB,35 KA all with built in Thermo Magnetic Release . |
| 189 | Guy assembly complete with7/10 SWGG.I. stay wire,140x85 mm H.T.guy insulator, 18mm dia stay rod 1.8 mtrs.Longwithbowthimble,turnbuckleand300x300x6mm anchor plate. |
| 190 | 11 KV, 3 Pole 400amp, Air Break G.O.S tilting type, three insulator per phase, complete with all fittings conforming to IS:9920 & IS: 9921 (Porcelain/Polymer) |
| 191 | 11KV,3Pole,400amp.D.O.FUnitcompletewithall accessories conforming to IS: 9385 (Porcelain/Polymer) |
| 192 | 9KV,5KAsinglepoleunitmetaloxidegaplessSurge Arrestorfor11KV,50c/ssolidlyearthedneutralsystem confirmingtoIS:3070(part-3)RaychemRPGmakeor equivalent. |
| 193 | SafeearthingmodelT-39shortcurrent50KArms for 1 sec (EHV) application: 80 mm diameter x 3 Mtrs. Electrode (Copper Bonded) & two bags backfill chemical compound. |
| 194 | Copper strips 25mm X 5mm from Cu. plate earth electrode |
| 195 | Danger board 11000 Volts. |
| 196 | G.I barbed wire for anti climbing device @ 2 kg./pole |
| 197 | Red oxide metal primer (NEROLAC or equivalent). @2ltrs/pole |
| 198 | Aluminium paint (NEROLAC or equivalent)[email protected]/pole |
| 199 | 110mm dia Rigid U PVC pipe as per IS 4985-2000 working pressure 6 kgf/cm2 (finolex) |
| 200 | Total cost of materials (External Electrification) |
| 201 | Excavation of 0.45x0.9x1.00 m cable trench in mix soil & re-filling with available excavated earth and providing cement concrete on the top of the trench |
| 202 | Concretingof 11Mtrs.Latticestructurein1:4:8ccin 0.9x0.9x1.75 mtrs. pit, constructionof parapet 0.61x0.61x0.153 mtrs. in 1:3:6 cc i/c 12mm cement plasterof parapet in 1:4 mix. |
| 203 | Placement of 750 - 1250 KVA distributionTransformer on parapetofsize2.2x2.2x1mtrs.In1:3:6ccMixincluding 12mm thick cement plaster in 1:4 Mix. |
| 204 | Concreting of H.T guy assembly in 1:4:8ccm in 0.40x0.40x1.05 Mtr.pit. |
| 205 | Fencingfor500KVAparapetmounteddistributionsub- station of size 3.5x4 mtrs.constructed with 50x50x5mm M.S angleverticalprops,35x35x6mmM.Sangle supports(double run), M.S wire mesh, 50x6mm M.S flat iron forclampingwiremeshcompletewithgatewithlocking arrangement, sitedevelopment, concretingof propsin 1:2:4 cc i/c soling & flooring works in 1:4:8 cc as per Layout No. 3/F/E&PD/400-750 KVA. |
| 206 | Air quality monitoring |
| 207 | Noise levels monitoring |
| 208 | Ground Water Quality |
| 209 | Surface Water Quality |