| 1 | Earth work in surface excavation exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: |
| 2 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 3 | Supplying and Filling in Plinth with Sand Under Floors including watering ramming consolidating and dressing complete |
| 4 | Supplying chemical emulsions in sealed containerincluding delivery at site Chlorpyriphos/Lindane Emulsifiable concentrate of 20% |
| 5 | Diluting and Injecting chemical for Post constructional anti termite treatment Excluding the cost of chemical emulsionTreament of Soil under existing floors using chemical emulsion @ 1 litre per hole,300 mm apart using 12 mm dia drilling holes and plugging with CM1:2 to match esisting floorWith Chlorphyros/Lindane E.C20% with 1% concentration |
| 6 | Treatment at point of contact of wood work by chemical emusion chlorpyriphos/Lindane in oil or kerosene based [email protected] per holes, by drillng 6 mm dia holes, at downward angle of 45 degrees@150 mm centre to centre and sealing the same |
| 7 | Providing and Laying cement Concrete 1:4:8(1cement:4 coarse sand(Zone-III):8graded stone aggregate 40 mm nominal size derived from natural resources) |
| 8 | Providing and Laying cement concrete in Retaining Walls Return Walls inlcuding attached pilasters,columns, piers, abutments, pillars posts struts, buttress,strings or laces courses, parapet,coping,bedblocks,anchorblocks,plain window sills fillets,sunken floor etc upto floor level five, excluding the cost of centreing shuttering and finishing1:3:6(1cement:3 coarse sand(Zone-III): 6graded stone aggregate 20 mm nominal size derived from natural resources) |
| 9 | Centering and Shuttering including strutting propping etc and removal of formwork for Foundation, Footings and Bases of columns For Bases of Retaining wall |
| 10 | Centering and Shuttering including strutting propping etc and removal of formwork for Foundation, Footings and Bases of columns For walls ofRetaining wall |
| 11 | For columns,abutmnets, posts,Pillars, Abutments |
| 12 | Suspended floors roofs landingsbalconies and access platforms with waterprrof ply 12mm thick |
| 13 | Lintels beams bressumers girders and cantilevers with water prrof 12 mm thikc ply |
| 14 | Providing and Laying Damp Proof Course 50 mm thick with cement concrete1:2:4(1cement:2 coarse sand(Zone-III): 4graded stone aggregate 20 mm nominal size derived from natural resources) |
| 15 | Making Plinth Protection 50 mm thick of cement concrete1:3:6 over 75 mm thick bed of Dry Brick Ballast 40 mm nominal size well rammed and consolidated and grouted with Fine Sand including necessary excavation, levelling, & dressing and finishing the top smooth |
| 16 | Providing and Laying in Position specified grade of reinforced Cement concrete excluding the cost of centering shuttering finishing and reinforcement:- All works upto plinth level |
| 17 | Reinforced cement concrete in beams , suspended floors,roofs having slope upto 15degree landings, balconies, shelves, chajja, lintels, bads, plain window sills, staircases, spiral staircases, above pinth level upto floor five, excluding cost of centering shuttering, finishing and reinforcement upto floor five1:1.5:3 derived from natural resources |
| 18 | Reinforced cement concrete works in walls, attached pilasters, columns, buttresses, string cpourses fillets,columns pillars posts abutments and struts above plinth level upto floor five excluding cost of centering shuttering finishing and reinforcement |
| 19 | Providing & doing Brick work with common burnt clay bricks FPSnon modularin below foundation of class designate 75 in foundation and plinth in CM1:4 |
| 20 | Providing & doing Brick work with common burnt clay bricks FPSnon modularin below foundation of class designate 75 above plinth in CM1:4 |
| 21 | Half Brick Mansonary with common burnt clay bricks non modular with class deignate 7.5 in super structure above plinth level upto level V in CM1:4 |
| 22 | Providing and Fixing 18 mm thick gang saw cut mirror plshed,premoulded and prepolished,machine cut for Kitchen Platforms,vanity counters,window sills,facias and similar locations of required size approved colour or texture laid over 20 mm thick base cement mortar 1:4(1 cement:4 coarse sand) joints treated with white cement,mixed with matching pigment,epoxy toch ups including rubbing curing,moulding of edges, polishing to give high gloss finish etcGranite stone slab of all colours except black, cherry or ruby red area of slab over 0.50 sqm |
| 23 | Providing edge moulding to 18 mm thick marble stone counters including machine polishing to give high gloss finish etc |
| 24 | Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 25 | Providing and fixing aluminium extruded section body tubular typeuniversal hydraulic door closer (having brand logo with ISi, IS : 3564,embossed on the body, door weight upto 36 kg to 80 kg and door widthfrom 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete |
| 26 | Providing & Fixing Ismarked Aluminum Butt Hingesanoidic coating not less than grade AC10 as per IS1868 transpared or dyed to required colour or shade with necessary screws etc100X63X3.2 mm |
| 27 | Providing & Fixing Is marked Aluminum Tower bolts barrel typeanoidic coating not less than grade AC10 as per IS1868 transpared or dyed to required colour or shade with necessary screws etc250X10 mm |
| 28 | Providing & Fixing Is marked Aluminum Handles typeanoidic coating not less than grade AC10 as per IS1868 transpared or dyed to required colour or shade with necessary screws etc125mm |
| 29 | Providing & Fixing Is marked Aluminum Door Stopper typeanoidic coating not less than grade AC10 as per IS1868 transpared or dyed to required colour or shade with necessary screws etc125mm Twin Rubber Stopper |
| 30 | Providing & Fixing of Aluminum Pull Bolt lockanoidic coating not less than grade AC10 as per IS1868 transpared or dyed to required colour or shade with necessary screws etc125mm Twin Rubber Stopper |
| 31 | Providing and Fixing brass finished 100 mortise lock and latch with six leversISI marked with screws etc |
| 32 | Providing & Fixing of Aluminum casement stays anoidic coating not less than grade AC10 as per IS1868 transpared or dyed to required colour or shade with necessary screws etc125mm Twin Rubber Stopper |
| 33 | Providing and Fixing Fly Proof Stainless steel grade 304 to windows and celestry windows using wire guage with average width of aperture 1.4 mm in both directions with wire of dia0.50 mm all complete with 12mm mild steel u beading |
| 34 | Structural steel work fixed with or without connecting plate including cutting hoisting fixing in position,and applying a priming coat of approved steel primer all complete |
| 35 | Providing & Fixing MSSheet Door Frame of 40X40X6 mm agnle iron3 mm gusset plates at the Junctions,and corners 25 mm dia pulley including all necessary fittings and primer coat of approved steel primer using MS agnles40X40X6 for diagonal braces |
| 36 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, includingcement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate |
| 37 | Extra for prefinishednosing to treads of steps of marble stone |
| 38 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 39 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. (a) Size of Tile 600x600 mm |
| 40 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % andonforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm |
| 41 | 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 coarse sand) |
| 42 | 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. 1:6 (1 cement: 6 coarse sand) |
| 43 | 6 mm cement plaster on celling (a) 1:3(1 cement:3 fine sand) |
| 44 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer. |
| 45 | Finishing walls with textured exterior paint of required shade: New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm |
| 46 | Painting withsynthetic enamel paint of approvedbrandand manufactureto give an even shade:Two or more coats on new work. |
| 47 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 48 | Providing & Fixing White Vitreous China Pedestal Type Water Closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : |
| 49 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever requiredWhite Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer |
| 50 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 51 | Providing and Fixing of Health Faucet(CP Brass/SS) with 1 m long flexible tube as approved by Engineer-In-Charge |
| 52 | Providing and Fixing mirror of superior class 600X450mm beveled edge mirror of approved quality complete with 6 mm thick hard board ground fxed to wooden cleats with brass screw and washers complete. |
| 53 | Providing & Fixing 600X120X5mm glass shelf with edges round off supported on anodised aluminium angle frame with CP brass brackets and guard rail complete fixed with 40 mm long screw rawl plug etc complete. |
| 54 | 600 mm long towelSS rail with total length of 645 mm, width 78mm and effective height of 88 mm, weighing not less than 190gms. |
| 55 | Providing and Fixing Drain Pipe PVC for Urinals Heavy Duty |
| 56 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing.his includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints , cutting, chases making good the wall complete as per direction of Engineer in Charge. Internal work concealed work cutting chasing and making good the wall.20 mm nominal dia pipes |
| 57 | Providing and fixing C.P. brass bib cock of approved quality conforming IS 8931 15mm nominal bore |
| 58 | Providing and fixing C.P. brass bib cock long body of approved quality conforming IS 8931 15mm nominal bore weight not less than 810 gms |
| 59 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 |
| 60 | Supply and Installing at site uPVC piping system using Solvent Cement ISI Marked [As perIS4985]with Heavy duty ISI Marked special fittings, Plain Bends ,Door bends, Coupler ,Reducers, Single Tees ,Door Tees, Double Tees, Reducing Tees, Plain, Ys, ,Door Ys, Double Ys, Elbows , Door Elbows,Floor traps(P,S type) etc. Adapters, Air vents, Clamping with GI UClamps as required for firmly installing the pipes. Testing of the system for leakage and Air tightness Complete 75 mm dia pipe(type B soil and Vent pipes) |
| 61 | Supply and Installing at site uPVC piping system using Solvent Cement ISI Marked [As perIS4985]with Heavy duty ISI Marked special fittings, Plain Bends ,Door bends, Coupler ,Reducers, Single Tees ,Door Tees, Double Tees, Reducing Tees, Plain, Ys, ,Door Ys, Double Ys, Elbows , Door Elbows,Floor traps(P,S type) etc. Adapters, Air vents, Clamping with GI UClamps as required for firmly installing the pipes. Testing of the system for leakage and Air tightness 100 mm dia pipe(type B soil and vent Pipes) |
| 62 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement: 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size),foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal Dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : |
| 63 | Extra depth for Manholessize 90X80 cm With common burnt clay F.P.S. (non modular)bricks of class designation 7.5 |
| 64 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than4.50 kg and frame to be not less than 2.70 kg as per standard design: 150X100mm size P type |
| 65 | Providing and fixing Sand Cast Iron grating for Gully trap 100 mm |
| 66 | Providing and Fixing SS grating 100 mm (lockable)(100 mm/75mm) dia for floor trap |
| 67 | Makinfg Soak Pit 2.5m dia 3 meter deep with 45X45cm dry brick honey comb shafts with bricks and SW drain pipe 100 mm dia meter 1.8m long complete as per Standard design with common burnt clay FPS non modular bricks pf class designate 75 |
| 68 | Providing and Fixing Float glass panes 4mm thick. |
| 69 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For fixed portion |
| 70 | For Openable Portion shutters of doors windows and ventilatorsFor shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) |
| 71 | Providing and fixing 12 mm thick pre laminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminium doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge.Pre-laminated particle board with decorative lamination on both sides. |
| 72 | Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-chargecomplete. Upto 5mm width and 5 mm depth |
| 73 | Providing & Fixing aluminium casement window fastner of required length for aluminium windows with necessary screws etc Anodised (AC15) Aluminium |
| 74 | Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer in-Charge. |
| 75 | Steel Reinforcement in RCC Works including straightening, cutting, bending and Fixing in Position, and Binding all complete upto plinth level TMT bars of FE500 or more grade |
| 76 | Steel Reinforcement in RCC Works including straightening, cutting, bending and Fixing in Position, and Binding all complete above plinth level TMT bars of FE500 or more grade |
| 77 | Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density. |
| 78 | 53 mm to 22.4 mm size stone aggregate [DSR-16.3.3] |
| 79 | Stone screening 11.2 mm nominal size (Type B) [DSR-16.3.7] |
| 80 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.63 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerincharge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 81 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7microns epoxy primer on both side of the sheet and polyester topcoat 15-18 microns using self drilling/ self tapping screws complete :Barge Board upto 300 mm |
| 82 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including, cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete Hot finished seamless type tubes |
| 83 | Cement Concrete1:2:4(1 cement:2 Coarse:4 40 mm aggregate) in pavements laid to required slope and camber, as required including consolidation finishing and tamping complete(In panels as per directions of Engineer-In-Charge) broom finish |