| 1 | Dismantling of plain or corrugated steel sheeting any guage, thickness including Nanital or similar pattern roof coverings complete all as specified and as directed. |
| 2 | Dismantling of wall and ceiling boards (fiber, pulp, insulation etc.) or insulation boards/slabs/blankets, any thickness, including frames and cover fillets complete all as specified and directed. |
| 3 | Dismantling wrought iron or mild steel work of any description not otherwise provided for |
| 4 | Dismantling timber scantlings in unframed timber work 40 sq.cm and over in section, in any position complete all as specified and as directed. |
| 5 | Demolition of reed, lathing, single or double, including battens and plaster or chicken wire lathing complete all as directed. |
| 6 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars etc. but excluding ashlar facings, dressed stone work & precast concrete articles complete all as specified & directed. |
| 7 | Demolition of unreinforced cement concrete in ground floors and pavings n. exc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 8 | M&L for plain cement concrete (1:3:6), type C-1, (using 20mm graded crushed stone aggregates) as in mass concrete, sub base , etccomplete all as specified and directed. |
| 9 | M&L for brick work with sub class old size \"B\" bricks, straight or curved on plan to any radius, built in cement mortar 1:4 as in half brick thick walls complete as specified and directed. |
| 10 | Supply & Fixing mild Steel work in hollow square/rectangular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S. 4923 -1997 (Reaffirmed 2009)grade Yst.-310 complete all as specified and directed. |
| 11 | Supply & Fixing plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment cofirming to Fe 410 -W (Gde- E- 250) quality-A complete all as specified and directed. |
| 12 | S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, orscrewed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, longbut length of bolt exc 5cm but n exc 10cm long complete all as specified & as directed. |
| 13 | M&L for second class hardwood, scantlings, wrought, fixed in unframed work complete as specified and directed. |
| 14 | S&F galvanised steel wire netting 0.71 mm dia and 25 mm size of mesh for lathing, fixed with tinned of wire staples to wooden frame in all including all laps, cutting and waste complete all as specified and directed. |
| 15 | M&L for rendering 15mm thick in CM 1:4 on fair faces of brick or concrete surfacesfinished even and smooth without using extra cement complete all as specified & directed. |
| 16 | M&L for preparation of new plastered surfaces of wall and preparing surfaces as directedand applying two coats of cement base paint over a coat of primer complete all as specified and directed. |
| 17 | M&L for rendering 10.mm thick plaster in cm 1:6 on fair faces of brick work or concrete surfacesincluding finishing top even and smooth without using extra cement complete all as specified & directed. |
| 18 | M&L for preparation of plastered surfaces of walls andapplying thin layer of wall care putty of 1 to 2mm thick and finally applying two coats of distemper oil emulsion over primer complete all as specified and directed. |
| 19 | M&L for pre-painted hot dip aluminium-zinc alloy metallic coated corrugated steel sheet, any pattern corresponding to IS15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ 150, 0.50mm thick of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed |
| 20 | M&L for hot dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ 150, 0.50mm thick of an approved colour and having yield strength of 550MPa as in ridge/valley/gutter/eaves boardings fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed. |
| 21 | Providing and fixing inter locking metal grid (snap grid for false ceiling) of size 605mm x 605mm in true horizonatal level, hot dipped galvanised steel sections consisting of main “T” runner with suitably spaced joints to get required length and size 24mm x 38mm made from 0.30mm thick (Min) sheet spaced at 1200mm centre to centre and cross “T” of size 24mm x 28mm made of 0.30mm thick (Min) sheet, 1200mm long spaced between main “T” at 600mm centre to centre to form a grid of 1200mm x 600mm and secondary cross “T” of length 600mm and size 24mm x 28mm made of 0.30mm thick (Min) sheet to be interlocked at middle of the 1200mm x 600mm panel to form grids of 600mm x 600mm and wall angle of size 24mm x 24mm x 0.4mm. Main “T” runner to be suspended from purlins or truss member using 2 to 3 mm dia GI wire, 1200mm x 600mm centre to centre all complete for all heights as per specifications and as directed by Engineer – in - Charge. |
| 22 | M & L for 4 mm thick non asbestos fibre cement decorative ceilingboards fixed or laid/ inserted to timber/GI/Aluminium framework with screws etc, complete all as per manufacturer instructions complete all as specified & as directed. |
| 23 | S&F framed work such as griils, grating, angle iron door frames etc., with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, barred iron doors, laders, framed balusters, walk ways, railings frame work of water tanks and similar work conforming to Fe-290. Gde E-165 complete all as specified & as directed. |
| 24 | Taking down chowkat or frame with shutters (without taking off shutters from the frame) not exceeding 1.5sqm each and making good to disturbed surfacescomplete all as specified and as directed by the Engineer-in-Charge. |
| 25 | Taking down chowkat or frame with shutters (without taking off shutters from the frame) exceeding 1.5sqm but not exceeding 4.0sqm each and making good to disturbed surfacescomplete all as specified and directed by the Engineer-in-Charge. |
| 26 | S & F for aluminum powder coated (powder coated of required colour) three track (2 Nos Glazed shutter & 1 Nos Gauzed shutter) sliding windows frame top & sides of size 92 x 31.75 x 1.50mm (section No 20831) bottom of size 92 x 31.75 x 1.50mm (Section of 20832) and shutter top & bottom of size 40 x 18 x 1.55 (section 20738) and lock side shutter frame of size 40 x 15 x 1.45mm (Section 20737) with rubber gasket, beading and locking arrangement including making good to the disturbed portion complete including stainless steel wire mesh 0.36mm nominal dia with 1.40mm average aperture and fixed with stainless steel wire staples and fixing 5mm thick glass with necessary rubber beading gasket etc complete all as specified & as directed. |
| 27 | S & F 2nd class Plain, solid straight chowket and frames wrought framed rebated on the solid rounded or chamfered put together with glue pinned at joints complete all as specified & as directed. |
| 28 | S&F 30 mm thick, laminated moulded Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides & fixed to chowkats ofcomplete all as specified & directed. |
| 29 | S&F 100mm size butt hinges, medium weight, cold rolled mild steel & fixed complete all as specified & as directed. |
| 30 | S&F 150 mm size, aluminium anodised , barrel tower bolts of extruded section & fixed completeall as specified and as directed. |
| 31 | S&F 150mm size aluminium handles, cast type, anodized and fixed complete all as specified & as directed. |
| 32 | S&F 300mm length of bolt, aluminium alloy, anodized,sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified & as directed. |
| 33 | S&FFloor door stopper doubled legedof aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified & as directed. |
| 34 | S&F MS chromium plated curtain rod 25 mm dia , with and including MS chromium plated decorative round finials on either end provide a visually balanced appearance including MS chromium plated brackets fixed to wall with 30 mm wooden steel screws and PVC rawl plug, anchors, and installation as in repair complete all as specified & as directed. |
| 35 | M&L for preparing new wood & wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified & directed. |
| 36 | M&L for preparation of new or previously steel surfaces of any description, over 10 cm width or girth, not otherwise described and evenly applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 37 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises all complete. |
| 38 | M&L for coloured non skid joint free ceramic tiles of 7mm to 8mm thick area of each tile exceeding 0.18 Sqm but not exceeding 0.38 sqm in floors, etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed or bedding layer in cement mortar 1:6 for laying floor finishes complete all as specified & directed. |
| 39 | M&L for coloured non skid joint free ceramic tiles of 7mm to 8mm thick area of each tile exceeding 0.18 Sqm but not exceeding 0.38 sqm in vertical surfaces such as skirting/dado, etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick rendering incement mortar 1:4 complete all as specified & directed. |
| 40 | M&L for coloured non skid joint free ceramic tiles / outdoor (capsulle type)of 7mm to 8mm thick area of each tile exceeding 0.06 Sqm but not exceeding 0.11 sqm in floor set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick rendering incement mortar 1:6 complete all as specified & directed. |
| 41 | M & L Plain fillets. of 2nd class soft wood of square, rectangular or triangular in section, clean sawn, secured with nails or brads.Exc 13 & nexc 25 sqcm complete all as specified & as directed. |
| 42 | M & L Solid PVC Wall Lining consisting of 5mm thick of wood grain printed on single side PVC sheet and other side balancing with plain colour inclusive of solvent cement and fixing at site on frame as per specifications and drawing complete all as specified & as directed. |
| 43 | Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators sockets etc. to be measured separately), removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors, etc complete all as directed by Engineer-in-Charge. |
| 44 | Material and labour for providing point wiring for controlled by one switch with using 1.5 sq.mm (nominal area), stranded copper conductor, single core PVC insulated FRLSH unsheathed cable (Maintaining Colour Code) 1100 volts grade with and including PVC casing and capping (size of casing caping as required at site but not less than 20mm) of suitable size including PVC accessories / fittings and fixtures fixed on surface with using new PVC board or sunken type pressed steel box of adequate size, terminal boxes for mounting fittings/junction boxes with and including all accessories and using 1.5 sq.mm (nominal area), stranded copper conductor, single core PVC insulated FRLSH unsheathed cable green in colour as in earth continuity conductor connected to common earth dolly and connecting upto fittings complete all as specified and directed for:- Note: The quoted rates shall be inclusive for fixing casing caping to surface with using PVC raw plugs and provision of PVC boards/terminal/junction boxes of any shape and size.(a) One light /Fan /Ex Fan point controlled by one, one way switch(b) One socket outlet 3 or 5 Pin, 6 Amp on independent board |
| 45 | All as per ItemNo. 44.00 here-in-before but for One socket outlet 3 or 5 Pin, 6 Amp on same board complete all as specified and as directed . |
| 46 | All as per Ser item No 44.00above but with 2.5 sqmm copper cable in and including PVC casing and capping complete all as specified and as directed. |
| 47 | S&F for switch paino flush type 6 Amps single pole one way 230 volts AC circuit complete all as specified and directed. |
| 48 | Fixing in repairswitch paino flush type 6 Amps single pole one way 230 volts AC obtained from taking down here-in-above complete all as directed. |
| 49 | S&F for socket outlet 2 in 1 3 pin 6 Amps flush type 230 volts AC circuit on same board complete all as specified and directed. |
| 50 | Fixing in repair socket outlet 2 in 1 3 pin 6 Amps flush type 230 volts AC circuit on same board obtained from taking down here-in-before complete all as direcetd. |
| 51 | S&F switch socket combination 2 in 1 3/5 pin 6 Amps 240 volts flush type multipurpose complete all as specified and as directed. |
| 52 | Fixing in repair switch socket combination 2 in 1 3/5 pin 6 Amps 240 volts obtained from taking down here-in-before complete all as directed. |
| 53 | S&F switch socket combination 2 in 1 5/6 pin, 16 Amps flush type 240 Volts universal complete all as specified and as directed. |
| 54 | Fixing in repair only switch socket combination 2 in 1 5/6 pin, 16 Amps flush type 240 Volts obtained from taking down here-in-before complete all as directed. |
| 55 | S&F Electronic fan regulator 230 volts, step type, flushtype,ISI Marked, complete all as specified and as directed. |
| 56 | Fixing in repair fan regulator 230 volts, step type, flushtype, obtained from taking down here-in-before complete all as directed. |
| 57 | M&L for ceiling rose, surface bakelite 65 x 17.50 mm of three terminals PVC/Polycarbonate, isolated body (ISI Marked) complete all as specified and as directed. |
| 58 | Fixing in repair ceiling rose obtained from taking down here-in-before complete all as directed. |
| 59 | S&F PVC/polycarbonate angular lamp holder insulated body with back plate angle type suitable for batten fittingcomplete all as specified and directed |
| 60 | Fixing in repair PVC/polycarbonate lamp holder obtained from taking down here-in-before complete all as direcetd. |
| 61 | S&F LED tube light fitting 4 ft. 1 x 18/20 watt, 230 volts, complete with all accessories internally pre-wired and fixed to walls/ceiling with screw including connecting up with twin coreflexible copper conductor cable with suitable size, complete all as specified and directed. |
| 62 | S&F LED tube light fitting 2 ft. 1 x 9/10 watt, 230 volts, complete with all accessories internally pre-wired and fixed to walls/ceiling with screw including connecting up with twin coreflexible copper conductor cable with suitable size, complete all as specified and directed. |
| 63 | Taking down carefully serviceable ceiling fans / Exhaust fans complete, removing its blade and to store for keeping in safe custody for reuse at sitec complete all as directed. |
| 64 | Hanging only ceiling fan any make/ sweep and connecting up with existing electric circuit complete received from MES Store Yard all as specified and directed. |