| 1 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. |
| 2 | Carriage of Material by Mechanical transport including loading ,unloading and stacking to municipal dump site. SeeHPPWD schedule of rates 2020 S.no. 1.1.4 column of 9.(3Km).as per directions of Enginner-in-charge. |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.(All kind of soil) |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 5 | Randam Rubble Masonry/ Polygonal Rubble Masonry (Uncoursed/Brought to Courses) withhard stone of approved quality in foundation and plinth including leveling up with cement Conckrete 1:6:12 ( 1-cement : 6-sand, 12 Aggregate 20 mm Nominal Size ) in cement mortar 1:6 (1-Cement, 6-Sand) in breast walls and R /walls. |
| 6 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.(All kind of soil) |
| 7 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 8 | Bed |
| 9 | sides |
| 10 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqmincluding grouting the joints with white cement and matching pigments etc., complete. (Size of tiles 600*600mm ) |
| 11 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. |
| 12 | Distempering with 1st quality Synthetic/acrylic distemper (ready mixed)of Asian/Nerolac Paint of approved shade and colour complete as per manufacturer\"sspecification .(i)Two or more coats on new work including carriage of materials in all leads and lifts by mechanical or manual means. |
| 13 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture |
| 14 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete |
| 15 | HDPE PIPEforDrainage 315mm dia |
| 16 | Electricity FittingWiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit with modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required. Group b. |
| 17 | Wiring for power plug with 2x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required. |
| 18 | Wiring for power plug with 4x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 2 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required. |
| 19 | Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No. HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required. |
| 20 | 2x1.5 Sq. mm. |
| 21 | 2x 10 Sq. mm.. |
| 22 | Supplying and drawing LAN cable CAT 6E, solid copper conductor protected with PVC sheath in the existing surface / recessed, steel / PVC conduit as required. |
| 23 | Supplying and fixing of following sizes of PVC conduit along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required: 20 mm. dia |
| 24 | Supplying and fixing following rating Modular switch /socket in the existing switch box / cover plate including connections etc. as required |
| 25 | Telephone. Socket outlet, modular. |
| 26 | Bell push |
| 27 | Supplying & fixing of G.I. modular boxes of following sizes along with modular base and cover plate for modular switches in recess as required:-2 modules (78mmx78mmx50mm) |
| 28 | Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 5 pin 5/6 amps modular socket outlet and 5/6 amps, modular switch, connections etc. as required. |
| 29 | Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps, modular switch, connections etc. as required. |
| 30 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V,complete as required. |
| 31 | Supplying and erection of following depth sheet metal cubical pedestal of suitable dimensions with plus-minus 5 cm variation, made from 1.6 mm thick M.S. sheet duly fabricated in a segregated manner for housing of switch fuse units, by welding each compartment on five sides & front side hinged, complete with locking arrangement, with sufficient No. vertical and horizontal intermediate switchgear housing compartments. The cubical pedestal shall have cable entry box at one or two sides, with epoxy powder coated approved paint and bonding to the existing earth etc. The same shall be erected in the 1:2:4 cement concrete plat-form of suitable dimensions 15 cm high from ground level and 45 cm thick. The cubical pedestal shall be 15 cm from the top of cement concrete plat-form:- 300 mm deep (nominal) |
| 32 | Supplying and fixing copper strip bus-bars suitable for 200 Amp. 415 volts capacity 4 No. each of cross-sectional area (25.4mmx4.75mm),in the existing enclosure with all accessories including connections etc. as required:- |
| 33 | Providing and fixing following rating and breaking capacity MCCB in the existing cubical panel board including drilling holes in the cubicle panel, making connections, etc. as required.150 Amp. -16 KA |
| 34 | Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, \"C\" curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:- Single pole. Cat-A. |
| 35 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 Amps. Cat-A. |
| 36 | Supplying and fixing following rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required 40 Amps. Cat-A. |
| 37 | Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wireset, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required Double door-12way |
| 38 | Earthing with G.I earth pipe 4.5 mtr. long and 40mm dia, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as required. |
| 39 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 40 | Supplying and erection of street light bracket made of G.I. pipe \"A\" class of suitable length and dia, the pipe bended to give an angle of 100 to 110 degree fitted with bolt & nuts atthe top of existing pole or wall including painting the pipe with two coats of approved paint over priming coat complete in all respects as required:-32 mm dia. G.I. pipe, heavy class |
| 41 | Providing and laying of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade direct in ground; to be laid 1 meter below the ground level including excavation and refilling the trench etc.as required, but excluding sand cushioning and protective covering:- moured cable 35sq. mm (3.5 core) |
| 42 | Providing, laying and fixing of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade on surface etc. of the required size:- Armoured cable 95 sq. mm (3.5 core) |
| 43 | Providing, Installation, testing and commissioning of ceiling fan with regulator, including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mm twin twisted flexible,cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required:-1200 mm |
| 44 | Providing and installation of exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required:- Exhaust Fan, light duty, 300 mm sweep |
| 45 | Providing and installation of following type of LED batten with aluminium housing, anti glare polycarbonate diffuser and energy efficient constantcurrent, integral electronic driver; suitable for input voltage: AC 220-240 V, 50/60Hz, complete with all accessories, including mounting clamps,connections, testing etc. as required: of Approved Make LEDBatten 18 watt |
| 46 | Supplying and fixing of fancy wall bracket suitable for input voltage: AC 220- 240 V, 50/60Hz, complete with all accessories, lamp holder, but excluding lamp including making connections, testing etc. as required: of Approved Make Wall light fixture Polycarbonate body, suitable for 9 W retrofit LED lamp B22 base. |
| 47 | Providing and installation of following type of surface mounting square/round type LED panel 6w Light with aluminium die cast housing in white finish with anti glare polycarbonate diffuser and seprated energy efficient constant current, non-integral, electronic driver; suitable for input voltage: AC 220-240 V, 50/60Hz, complete with all accessories, connections, testing etc. as required: of Approved Make |
| 48 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 49 | Providing,and fixing of Fan Box as required and approved by Engineer in charge. |
| 50 | Providing and fixing LED tube 10 watt 2F of Extuded Aluminium Led Batten product code BCLSB 10 W cool white of bajaj or equivalent make as required and approved by the Enginner-in-Charge. |
| 51 | Providing and fixing Street light with die cast housing with toughned glass with IP 66 protectionproduct code BRTFG 45 W LED I of bajaj orequivalent make as required and approved by the Engineer-in- Charge. |
| 52 | Sanitary InstallationProviding and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. Internal work |
| 53 | ( a ) 25 mm nominal bore |
| 54 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :. 25 to 40 mm nominal bore |
| 55 | Fixing water meter and stop cock in G.I. pipe line including cutting and threading the pipe and making long screws etc. complete (cost of water meter and stop cock to be paid separately). |
| 56 | Providing and fixing Polyethelene-AluminiumPolyethelene PE-AL- PE Composite Pressure Pipes conforming to IS - 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers & connectors etc., with clamps at 1.00 metre spacing. This includes the costs of cutting chases and including testing of joints complete as per direction of the engineer in charge. Concealed work, including cutting chases and making good the wall etc. |
| 57 | (ii) 1216 (16 mm OD) pipe |
| 58 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid |
| 59 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 60 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe 40mm dia |
| 61 | Providing and fixing uplasticised PVC connection pipe with brass unions 45 cm length 15 mm nominal bore |
| 62 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work 20mm dia) |
| 63 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete |
| 64 | Providing and fixing C.P. brass long nose bib cock Cat no.CON 107KNJaquar or equivalentsingle controlof approved quality conforming to IS standards. 15 mm nominal bore |
| 65 | Fixing water meter and stop cock in G.I. pipe line including cutting and threading the pipe and making long screws etc. complete (cost of water meter and stop cock to be paid separately). |
| 66 | Providing and Fixing Soap dish stainless steel CAN -1131N of Jaquar or equivalentcomplete in all respect. |
| 67 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. |
| 68 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. |
| 69 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : |
| 70 | 25mm |
| 71 | Providing and fixing Polyethelene-Aluminium-Polyethelene PE-AL-PE Composite tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 72 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 25 mm nominal bore |
| 73 | Providing and fixing high pressure PVC spigot and socket, waste and ventilating pipes ISI marked including fixing with approved adhesive etc. complete 110 mm |
| 74 | Providing and fixing high pressure PVC spigot and socket, waste and ventilating pipes ISI marked including fixing with approved adhesive etc. complete 150 mm |
| 75 | Providing and fixing PVC floor trap of self cleaning design including fixing with approved adhesive, cost of cutting and making good the wall and floors etc. complete. 110 mm X 90 mm |
| 76 | Providing and fixing PVC door bend with ovalaccess door, insertion rubber washer 3 mm thick bolts and nuts ISI marked complete including fixing with approved adhesive etc. |
| 77 | I) 110mm dia |
| 78 | II) 150 mm dia |
| 79 | Providing and fixing PVC plain bend ISI marked including fixing with approved adhesive etc. complete. |
| 80 | I) 110mm dia |
| 81 | II) 150mm dia |
| 82 | Providing and fixing PVC plain double equal branch ISI marked including fixing withapproved adhesive etc. complete. |
| 83 | I) 110mm dia |
| 84 | II) 150mm dia |
| 85 | Providing and fixing PVC single equal branch with oval access door, ISI marked insertion rubber washer 3 mm thick bolts and nuts complete including fixing with approved adhesive etc. complete |
| 86 | I) 110mm dia |
| 87 | II) 150mm dia |
| 88 | Providing and fixing PVC collars ISI marked including fixing with approved adhesive etc.complete. |
| 89 | I) 110mm dia |
| 90 | II) 150mm dia |
| 91 | Providing and fixing PVC clamps ISI marked of approved design with steel screws and rawal plugs etc. complete. |
| 92 | I) 110mm dia |
| 93 | II) 150mm dia |
| 94 | Constructing masonry Chamber 90x90x100 cm inside, inbrick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 |