| 1 | Dismantling of mild steel work (Trench Cover, Door, Window, railing etc.). |
| 2 | Demolition of brick work built in cement mortar. |
| 3 | Taking down CI rain water pipe any size including fittings. |
| 4 | M/L Brick work with sub class B bricks straight or curved on plan exc. 6m mean radius built in 1:4 cement mortar. |
| 5 | Taking down of cement plaster on brick wall including taking out joints, hacking for key, scrubbing down with water etc. alongwith brushing with neat cement slurry @ 3 Kg of cement per Sqm and Rendering 15mm thick on fair faces of brick work or concrete surfaces with 1:4 cement plaster and surface to be finished even and smooth (without using extra cement) |
| 6 | Cutting holes in brick walls built in cement mortar Exc. Half brick but n. exc. 1 brick. |
| 7 | Taking down chowkhats or frames with shutters (without taking off shutters from the frame) exc. 1.5 sqm but n exc. 4 sqm each. |
| 8 | Providing PCC type A-1, M-20, 1:1.5:3 (20mm graded aggregate) |
| 9 | Material and labour for providing and applying of Epoxy PU flooring system of 5mm thicknesscomprising of one coat of primer, 3mm thick Epoxy underlay screed and 2mm thick Epoxy PU floor all as described in Annexure \"A\" . Colour shall be as approved by EIC. |
| 10 | S & F of mild steel work for trench covers with joist, angle, channel, plain and chequered plates alongwith railing, pit coverand grill etc. complete with cutting and welding. Fe 410-W(Gde-E-250) quality A. |
| 11 | S&F of Suspended false ceiling with G.I. (powder coated) frame work, Make- Gyproc/Armstrong/RK plain, Main Runner angleshallbe of G.I. 20x20x3000mm size and 0.35 mm thick,Main Tee Section24x32x3000mm size and 0.50mm thick and Cross Tee Section24x26x1200mm & 24x26x600mm size and 0.50mm thick. False Ceiling boards of Tegular finish (14 mm thick), Make: ArmstrongBeauti Sky RH 90 orequivalentas directed by EIC. Size shall be of (600X600x14)mm (nominal).Allnecessary fittingsand accessories shall be provided bythe contractor. |
| 12 | Supply and fixing factory made uPVC white colour casement window single panel with SS friction hinges (300X19X1.9mm), made of (small series) frame 47x50mm & sash 47x68mm both having wall thickness of 1.9± 0.2mm and single glass pane glazing bead of appropriate dimension. (Area of window upto 0.75sqm) comprising of uPVC multi-chambered frame, sash and mullion (wherever required)extruded profiles duly reinforced with 1.60± 0.2mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated)casement handles, GI fasteners (100 X 8mm) size for fixingframe to finished wall, plastic packers, plastic capsand necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, complete all as specified and directed by Engineer-in- Charge. Glass shall be paid separately. Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 13 | Supply and fixing factory made uPVC white colour casement door with 3D hinges made of (big series) frame 67x64mm & sash 67x110mm both having wall thickness of 2.30± 0.2mm and single glazing bead/double glazing bead of appropriate dimension. (Area of door upto 2.00sqm ) comprising of uPVC multi-chambered frame,sash and mullion (wherever required) extruded profiles duly reinforced with 1.60± 0.2mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC, extruded glazing beads, uPVC extruded interlock and uPVC extruded line sash adaptor (if required), EPDM gasket,zinc alloy (white powder coated) 3D hinges and 01 handleeach side ofpanels along with zinc plated mild steel multipoint locking, having transmission gear, cylinder with keeps and one side key, GI fasteners 100X8mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, complete all as specified and directed by Engineer-in- Charge. Glass shall be paid separatelyNote: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 14 | S/F sheet glass ordinary quality and glazing in squareexc. 0.5 sqmin each pane of 5.5 mm thick. |
| 15 | S/F 150mm dia PVC SWR pipe socketed & jointed with cement solvent jointer & accessories. Make- Supreme/Prince/Finolex. |
| 16 | S/F PVC SWR bend / shoe for 150mm dia PVC pipe. Make- Supreme/Prince/Finolex. |
| 17 | Preparation of new painted steel surfaces and applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer. Make: ASIAN (Apcolite) /BERGER (Luxul High Gloss). |
| 18 | Applying 3mm thick wall care putty on wall surfaces with making completesmooth surface.Make:Birla /J.K.Wall Putty as directed by EIC. |
| 19 | Preparation of old painted surfaces and applyingtwo coat of 1stquality premium Acrylic emulsion painton Wall and ceilingsurfaces over one coat of primer. Make: Asian (Tractor Acrylic emulsion)/ Berger (Silk Luxury emulsion) as directed by EIC. |
| 20 | Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers/PU having Sun Reflectivity Index (SRI) of 105 or more on top of concrete roof in 3 coats @ 10.76 litre per 10 square meter. One coat of self - priming elastomeric waterproofing liquid (dilution with water in the ratio of 3:1 i.e.3 parts of waterproofing liquid and 1 part of water) and two coats of undiluted elastomeric water proofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer in Charge. Make:- Asian/Nerolac/Dr.Fixit. Firm i.e.Contractor (not OEM) will provide minimum 6 years warranty of the above system and will carry out any repair free of cost if leakage or seepage is found through the above applied system. |
| 21 | Taking down carefully copper/aluminium point wiring of [light, fan, socket (5A &15A)] complete with fittings such as switches, ceiling roses, pendants, regulators etc.). Removed materials to be stored and shiftedin safe custody for reuse and disturbed surfaces of walls, floors, etc. to be made good. |
| 22 | Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed conduit wiring, etc., and making good, cutting not to exceed 10 cm girth. |
| 23 | S & L for concealed point wiring for the 1100 volt FRLSH grade PVC insulated and unsheathed cable 1.5 sq mm (nominal area) single core multistranded copper conductor [red colour for phase, black colour for neutral and green colour for earthing lead (earthing lead to be connected to common earth)] through high grade ISI marked PVC conduit (S & L of PVC condute included in scope of work) of appropriate size (not less than 25 mm dia) concealed in wall and surface on ceiling complete with all accessories as specified for following :- Note : (i).The cuttingchases to be done for concealed conduit and shall be finished with cement mortar (1:3) and surface shall be matched with existing surface by using putty, POP etc and applying finishing coat of existing treatment without any extra cost.(ii) Make of all Cables should be Finolex/ Polycab/ Gloster. (iii) Make of PVC Conduit should be of Finolex/ AKG/ JindalOne light and fan point control by one switch |
| 24 | 15 amps, independent point wiring, with cables of 2.5 sq. mm single core multistranded copper conductor as phase & neutral wire and 1.5 sq mm single core multistranded copper conductor as earth wire copper conductor cable. (red colour for phase, black colour for neutral and green colour for earth wire to be used) |
| 25 | ditto as per item No. 24 above but wire 4.0sq mm single core multistranded copper conductor cable for phase & neutral with 2.5 sq mm single core multistranded copper conductor cable as earth continuity conductor. (red colour for phase, black colour for neutral and green colour for earth wire to be used)(for AC point wiring) |
| 26 | Supply and fixing of single phase and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps, C-Curve complete as specified at locations directed by WIC/EIC. Make should be of L&T/ ABB/ SIEMENS/INDOASIAN/HAGER/C&S. (for ACs). |
| 27 | Supply and fixing of VTPN DB 06 way vertical type 415 V, double door including three phase bus bar arrangement for fitting of MCBs, neutral & earthing busbar suitable for housing of 200 Amps MCCB as main incoming. Make should be of ABB/Legrand/Schnider/L&T/Siemens/Hager/Indoasian. The old existing three phase DB to be disconnected, removed and shifted in safe custody of EMS Section. |
| 28 | S & F of SPN DB Double Door 12 Way with 200 Amps rated copper bus bar Make should be of ABB /Legrand /Schnider /L&T /Siemens. The old existing SPNDB to be disconnected, removed and shifted in safe custody of EMS Section. |
| 29 | S & L of sub main wiring for circuit of size 10 sq mm 2 core 1100 volts grade FRLS PVC insulated multistranded copper conductor alongwith earth wire of 06 sq mm single core 1100 volts grade FRLS PVC insulated multistranded copper conductor unsheathed cable,1100 volts grade with multistranded copper conductor including PVC conduit of suitable size complete all as specified and directed by Engr-in-Charge. Make of cable should be of Finolex, Polycab, Gloster. (for connecting incoming supply to SPN DB ) |
| 30 | S & L of sub main wiring for circuit of size 4 sq mm 2 core 1100 volts grade FRLS PVC insulated multistranded copper conductor alongwith earth wire of 2.5 sq mm single core 1100 volts grade FRLS PVC insulated multistranded copper conductor unsheathed cable,1100 volts grade with multistranded copper conductor including PVC conduit of suitable size complete all as specified and directed by Engr-in-Charge. Make of cable should be of Finolex, Polycab, Gloster. (for connecting supply to SPN DB to modular switch boards ) |
| 31 | Supply and fixing of ceiling rose three terminal Make: L&T, Havells, Anchor. |
| 32 | S&F Modular Fan step regulator, 120W - 2 module |
| 33 | S & F of Modular Switch 1 way6 amp, 1 module. Make: L&T, Havells, Anchor. |
| 34 | S & F of Modular Socket, 6A - 2/3 pin combined 2 module, Make: L&T, Havells, Anchor. |
| 35 | S & F of Modular switch 1 way 16A, 1 module. Make: L&T, Havells, Anchor. |
| 36 | S & F of Modular Socket 6A/16A - 2/3 pin combined2 module, Make: L&T, Havells, Anchor. |
| 37 | S & F of Modular Metal flush box 3 module. Make: L&T, Havells, Anchor. |
| 38 | S & F of Modular White cover plate with frame, 3 module. Make: L&T, Havells, Anchor. |
| 39 | S & F of Modular Metal flush box 6 module. Make: L&T, Havells,Anchor. |
| 40 | S & F of Modular White cover plate with frame, 6 module. Make: L&T, Havells, Anchor. |
| 41 | Supply and fixing of MCCB 160 Amps, 4 Pole, 36 KA, including all accessories like spider link, shunt release, under voltage release etc. suitable to be fixed in 06 way VTPN DB as a incomer complete all as specified and directed. Make should be of L&T, Siemens, ABB. |
| 42 | S & F of MCB SP 40 Amps C-Curve Make should be of L&T, Siemens, ABB. (to be fitted in VTPN DB for ACs) |
| 43 | S & F of MCB SP 6-32 Amps C-Curve Make should be of L&T, Siemens, ABB. (to be fitted in SPN DB for light,fan circuits). |
| 44 | S & F of MCB SP 63 Amps C-Curve Make should be of L&T, Siemens, ABB. |
| 45 | S & F of Isolator DP 63 Amps Make should be of L&T, Siemens, ABB. (to be fitted in SPN DB as incomer). |
| 46 | S & F of MCB TP 25-63 Amps C-Curve Make should be of L&T, Siemens, ABB. (to be fitted in VTPN DB). |
| 47 | Supply and fixing of LED 36 watt suitable for armstrong/Grid ceiling of size (600 x 600) mm or 2\"x2\" complete connecting to existing ceiling rose with three core flexible wireall as specified and directed by WIC/EIC. Make: Philips (RC380B LED36S 6500 G4 L60 W60 PSU OD) or equivalent in GE. |
| 48 | Supply and fixing LED tube lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. |
| 49 | Taking down old u/s fan, sealing cable end,dismantling blades and deposited to factory authorities |
| 50 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor(BLDC). Make: Philips/Havells/Bajaj |
| 51 | Supply and installation hi wall split units 1.5 TR inverter type AC indoor/outdoor complete with cordless remote control unit and with copper condenser coil and minimum 6 m copper tube for connecting indoor and outdoor units and with minimum 5 star latest BEE rating. Make: Blue star, O-General, Carrier. |