| 1 | Wiring for light/fan point/exhaust fan point/call bell point with 1.5sqmm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit with piano type switch, phenolic laminated sheet, suitable size M.S box and earthing the point with 1.5 Sqmm FRLS PVC insulated copper conductor single core cable etc.as required. |
| 2 | Group - A |
| 3 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 4 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 5 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 6 | 2 x 6 Sqmm + 1 x 6 sqmm earth wire |
| 7 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. |
| 8 | 5/6 A switch |
| 9 | 3 pin 5/6 A socket outlet |
| 10 | Supplying and fixing metal box of 150 mm X 75 mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required. |
| 11 | Supplying and fixing metal box of 180 mm X 100 mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 A & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required. |
| 12 | Supplying and fixing of 4wayPVC gang Box of 6\" X 3.5\" size onsurface with ISI marks including providing and fixing 2 Nos.3 pin 5/6 Amps PT Socket outlet and 2 Nos. 05/06 Amps PT switch, connection, painting etc. as required. |
| 13 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 14 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. |
| 15 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 16 | Installation, testing and commisioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper condutor, single core cable etc. as required. |
| 17 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 18 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
| 19 | Upto 450 mm sweep |
| 20 | Supplying and fixing PVC batten/ angle holder including connections etc. as required. |
| 21 | Supplying and fixing following way,single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator) |
| 22 | 8 way , Double door |
| 23 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 24 | Single pole |
| 25 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 26 | 40 A |
| 27 | Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required |
| 28 | Providing and fixing 4.00mm dia copper wire on surface or recess for loop earthing as required. |
| 29 | Supplying, Installation, Testing and Commissioning of ASHLOK Make SEE brand saf earthing electrode type-19, 50mm dia, length 2 Mtr (short time current- 52.6rms for 1 sec, peak - 125.6) with back fill compound including providing masonary enclosure with cover plate having locking arrangement etc. as required. |
| 30 | Supplying of Surface mounted LED Batten Luminaires with Lamp type 20W LED 6500K, Make: Polycab, Intenso 20W LXS Batten, 220-240V, White or its equivalentas approved by Engineer - in - Charge. |
| 31 | Supplying of 5 star, 35W (BLDC Type) energy saving A.C Ceiling fan, 1200mm sweep for operation of 230V, with all accessories etc as required. Make:- Crompton, Model : Energion High Speed, Color: White or Equivalentas approved by EIC. |
| 32 | Supplying of Exhaust Fan 250mm Sweep (Non Mettalic Type) with all accessories etc as required.Make:-Havells, Model: Ventil Air-DX White or itsEquivalent to ISI as approved by EIC |
| 33 | Supplying & fixing of 10W LED lamps with light output of 950 lumenMake:- Havells or its equivalent to ISI . |
| 34 | Supplying and fixing T.W Board of 250mm x 300mm x 60mm deep (nominal size) on surface for installation of Energy meter as required. |