}

Tender For Construction Work Of Building In Primary School Jasola - Excavation In Foundation In Ordinary Soil (Loam, Clay Or Sand ) Including Lift Upto 1.50 M And Lead Upto 30 M And Including Filling Watering And Ramming Of Excavated Earth Into Trenches O, agra-Uttar Pradesh

Rural Engineering Department has published Tender For Construction Work Of Building In Primary School Jasola - Excavation In Foundation In Ordinary Soil (Loam, Clay Or Sand ) Including Lift Upto 1.50 M And Lead Upto 30 M And Including Filling Watering And Ramming Of Excavated Earth Into Trenches O. Submission Date for this Tender is 09-06-2025. Building Work Tenders in agra Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

49472645
Tender For Construction Work Of Building In Primary School Jasola - Excavation In Foundation In Ordinary Soil (Loam, Clay Or Sand ) Including Lift Upto 1.50 M And Lead Upto 30 M And Including Filling Watering And Ramming Of Excavated Earth Into Trenches O
Tender
Indian
Uttar Pradesh
Agra
09-06-2025

Tender Details

Tender For Construction work of building in primary school Jasola - Excavation in foundation in ordinary soil (Loam, Clay or Sand ) including lift upto 1.50 m and lead upto 30 m and including filling watering and ramming of excavated earth into trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by Engineer In-Charge upto distance of 30m from the foundation trenches. as per SI No.251 2 Antitermite treatment of along external wall where the apron is not provided using chemical emulsion @ 7.5 liters / sqm of the vertical surface of the substructure to a depth of 300 mm including excavation channel along the wall & rodding etc. complete. with chlorpyriphos / lindane E.C. 20% with 1 %concentration as per Iten no. New 1 3 Providing and laying Cement Concrete in 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) and curring complete, including cost of form work. in foundation and floors. As per CH - 5 SI No. 4.1.8 4 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. including cost of centering, shuttering, finishing and excluding reinforcment 1:1.5:3 (1 Cement : 1.5 coarse sand : 3graded stone aggregate 20mm nominal size). as per CH - 5 SI no. 5.2.2 5 Class-150 (Non Modular) brick work in 1:6 Cement and Coarse sand mortar in foundation and plinth including supply of all materials, labour and T&P etc. required for proper completion of the work. as per CH - 6S I No.6.1.2 6 Earth work in cutting or in embankment in ordinary soil excavation to be in the form of a regular pits not exceeding 0.50m in depth and earth work in embankment to be in 20cm layers including ramming and dressing the surface to required levels and slopes and also including 1.5 m lift and 30m lead. the earth in form of cutting to be used as spoil banks within 50m distance as directed by the Engineer-in-charge. and 3km cartage of earth. as per CH - 4si no. 253+253(b) 7 Reinforced cement concrete work in beams, lintels suspended floors, roofs having balconies, shelves, chajjas, bands, staircase and spiral stair cases above plinth level up to floorr five level, including cost of centering, shuttering, finishing and reinforcment, with 1:1.5:3 (1 Cement : 1.5 coarse sand : 3graded stone aggregate 20mm nominal size). as per CH - 5 SI no. 5.3 8 Class-150 (Non Modular) brick work in 1:6 Cement and Coarse sand mortar in super structere above plinth up to floor five level including necessary cutting and moulding of brick work as required and also including honeycombed brick work in thickness of wall more then 12cm. and including supply of all materials, labour and T&P etc. required for proper completion of the work.as per CH - 6 S I No. 6.1.2+6.8A 9 R.C.C. work providing and laying in position specified grade of reinforced cement concrete, slab including the cost of centering, shuttering, finishing and excluding reinforcment, above plinth level up to fifth floor level in1:1.5:3 (1 Cement : 1.5 coarse sand : 3graded stone aggregate 20mm nominal size). as per CH - 5 Si no. 5.1.2 10 Mild Steel or iron work In plain work such as reinforced concrete or reinforced brick work (when not included in and an over all rates) brought to required shape as necessary including bending for proper completeion of the work and excluding the supply of steel and its wastage bend, hooks and anththourized over lapping shall be measured upto floor to level.(8+10+12+16+20) MMDia 11 12mm Cement plaster with Cement mortar in proportion of 1:6 cement and fine sand (Dholpur sand) (Not less than in 1.25 FM) of single coat of interior plastering upto floor two level including internal rounded angles chamfers, and rounded angles not exceeding 80mm in girth and finished even and smooth. as per CH -13 si no. 13.1.2 12 15mm Cement plaster with Cement mortar in proportion of 1:6 cement and fine sand (Dholpur sand) (Not less than in 1.25 FM) of single coat of interior plastering upto floor two level including internal rounded angles chamfers, and rounded angles not exceeding 80mm in girth and finished even and smooth. as per CH - 13 si no. 13.2.2 13 Mild steel or iron work in heavy sizes such as built up gates record rack, roof work, gates etc. brought to required form including drilling holes revitting or welding where necessary, and also including supply of steel bolts, nuts, wastage etc. and their fixing require for proper completion of the work.as per CH- 10 si no. 10.31 14 Cement concrete Flooring in 1:2:4 ( 1 cemet : 2 Corse sand : 4 graded stone of size 20 mm nominal size) laid in one layer finished with floating coat of neat cement (40 mm thick floor) as per ch - 14 si no. 11.3.1 15 Providing and fixing glass strip of 4 mm thick in joints of floor and skarting at the time of laying including labour, T & P etc. all complete. As per ch - 14 SI No. 11.13 16 Precast Chequerred CC tiles 20mm thick with white, black or white and black marble chip of size upto 6mm laid in floors, treads of steps and landing on bed of 25mm average thickness of cement mortar 1:3 ( Cement and coarse sand) jointed with neat cement slurry mixed with pigment to match the shade of tile including rubbing an polishing complete with precast tiles of coloured with white cement. as per ch -14 si no. 11.20.1A 17 Finishing walls with water proofing cement paint of approved make such as super snowcem, durocem, Robiance, Guttucem, supercem quality and of required shade on under coated wall surface (One coat) over and including one coat white cement primer to give and even shade after thoroughly after brushing the surface. as perch 15 si no. 13.44.1 18 Distempering with Oil Bond distemper of approved brand ( two coats) and required shade on undecorated wall surface to give an even shade over and including priming coat of whiting after thoroughly brushing the surface free from dropping & other foreign matter including preparing the surface even and sand papered smooth. as per ch 15 si No. 13.41.1 19 Painting two coat and Applying priming coat over new steel and other metal surface upto 10cm. In width or girth or small not exceeding 0.10 sq.m. area after and including perparing the surface by thoroughly clearing oil, grease, dirt and other foreign matter and scoured with wire brushed, fine steel/wood. scrapper, sand papering and knotting including cost of all materials, labour T&P etc. required for proper completion of work. as per ch 15 si no. NEW 641,13.50.3+13.61.1 20 Finishing wall with putty approved brand and manufacture and of requried shade on undacorated wall surface to give even shade over including curring and cost of all material, labour, T&P etc. required for proper completion of work. As per ch 15 si no. 13.26 21 Cement concrete Flooring in 1:2:4 ( 1 cemet : 2 Corse sand : 4 graded stone of size 12.5 mm nominal size) laid in one layer finished with floating coat of neat cement (25mm thick floor) as per ch - 14 si no. 11.3.1.A 22 Providing and Fixing of glass strips of 4mm thick in joints of floor and skirting at the time of laying including labour, T&P etc. complete in all respect. As perch 14 Si no. 11.13 23 Cement Concrete topping 1:2 Cement and aggregate og size 4.75 mm and below by volume laid over and finished monolithic with structer slab. As per SI No. 14.66 24 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermalexpansion, (i) single socketed pipes. As per si no. 12.41.2 25 Wiring point for light with 1.5 sq.mm.FRLSHPVCinsulated multistrand single core copper conductor cablein PVC conduit partly concealed in the wall and partly laid in slab alongwith the reinforcement before concreting, complete with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside,GP Box, piano type switch & ceiling rose/angle/batten holder on 3mm thickphenolic laminated backalite sheet etc complete in all respect as directed including matching colour wash.SI No. 138 C 26 Wiring point for fan / fresh air fan (light duty exhaust fan) with 1.5 sq.mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit partly concealed in wall and partly laid in slab alongwith the reinforcement before concreting,complete with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside,GP Box , piano type switch & ceiling rose on 3 mm. thick backelite sheet etc., complete in all respect including matching colour wash.SI No. 140 C 27 Wiringpointforplugwith 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable inPVC conduit partly concealed in wall and partly laid in slab alongwith the reinforcementbefore concreting, complete with 1.5 sq. mm.FRLSH PVC insulatedmultistrandcopperconductorcable asearthwire drawninside the conduit. and piano typeswitch and socket etc., complete in all respect including matching colour wash. SI No. 141 C 28 Supply and fixing of power plug with 15A/250 voltflush type switch and 5 pin 15A/250V flush type universal socket in suitable M.S. box of 175mm x 100mm x 50mm size with phenolic laminated bakelite sheet cover 3mm thick fixed with brass machine screw and cup washer. SI No. 1139 29 Supply and fixing of electronic fan regulator 120-280 V. ISI marked, on the existing switch board including making connections, required material, labour T&P etc. for proper completion of work to the satisfaction of Engineer in charge of work.. SI No. 1203 A 30 Supply and fixing ofLED Tube Light with batten suitable for up to 1 X 22 watt LED tube light fittingincluding tube on Surface complete in all respect. SI No. 1413A Cat A 31 Supply and wiring of submain with two number2.5sq.mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia heavy duty (2mm thick) PVC conduit partly laid in slab alongwith reinforcement before concreting and partly concealed in wall, with 1 nos. 1.5 sq. mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable as earth continuity wire drawn inside the conduitetc, complete in all respects including matching colour wash. SI No. 1307 C 32 S & F surface/Flush mounting 12 ways SPN distribution board with additional metal doorwithout MCB complete in all respect, asDirect by Engineer in Charge. S.I. No. 1025 A Cat B 33 S&F of 6 Amp to 32 Amp. SPMCB (10 KA) C Curve SI No. 1002 Cat A 34 S&F of 32Amp. DP MCB (10 KA) C Curve SI No. 1009 Cat A 35 Supply and fixing hexagonal/Round G.P.fan box of approved make made up of 1.0 mm thickISI Marked G.P.sheet spot welded Four to Eightholes of 25.4 mm for pipe entryof the box. Holes should be semi-shuttered type with 0.5 mm G.P. Sheet made upper & lower cover duly screwed fitted with 300 mmround zink coted M.SBar X 12 mm& brand name should be embossed. Fixing with wiring conduit laid in the R.C.C. roof before concretingalongwith supply of all material, labour, T&P etc. required for proper completion of the work. SI No. 1149 36 Supply of BEE 5 Star rated-1200mm sweep ceiling fans with fan motor of A.C permanent insulation,capacitor rating confirming BEE 5 star rating and IS:374/79 and also comply with IS:1709/1984 with latest amendment. The rated voltge 220/240 volts, 50Hz, 1-ph AC the fan assemble should consists of down rod blades, shackle canopies etc and with double ball bearing system. SI No. 1501 (i) 37 Erection and testing of ceiling fan and regulator for room height upto 3.5 metres including supply of 3mm thick G.I.Pipe19mm dia. Duly painted, complete in all respect. SI No. 1116 38 Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 2000mm, outer pipe 50mm, inner pipe 25, terminal Dia 12 mm, outer GI pipe of 16 swgand inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonry husing SI No. 725A 39 Add for Invertor Wiring in wiring Point for light/ Fan/ Plug with 1.5 mm Cu Wire SI No. 189A 40 S/F of Sign board / inaugration stone 41 ADD GST

Key Value

Document Fees
INR 854 /-
EMD
INR 31000.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail