| 1 | Notes for item No 01 to 18 : (i) Material required for white wash, cement base paint distemper, synthetic enamel paint, external weather proof paint internal emulson paint required as per company specificaton shall be brought in sealed pack/ container and kept in office store and shall be issued to the contractor when required as per consumption.(ii)Paint/White wash shall be carried out only after laying neccessary protection covers/ papers to avoid paint splashes on floors.(iii) Distemper/ emulsion / external emulsion/ synthetic enamel/ primer shall onlyapplied with same brand rollers and tools as approved material make.(iv) Colour of paint may vary from building to building as order by GE without any extra cost to the Govt.(v) Weather proof painting on new surfaces and complete removal surfaces shall be done by authorised applicator and guarantee as per CA shall be obtained from applicator.(vi) The work shall be carried out in upto G+3 storeyed bldg. Cost of scaffolding, safety gears and other T&P deemed to be inclusive in quoted rate of respective items. |
| 2 | M&L for Preparation of old plastered surfaces of walls, cornices etc and applying one coat of white washing and all as specified and directed by Engr-in Charge. |
| 3 | All as per item No. 1 here-in-before but on ceilings. |
| 4 | M&L for preparation of old plastered/unplastered surfaces of walls and applying one coat of cement base paint and all as specified and directed by Engr-in Charge. |
| 5 | M&L for preparation of old plastered/unplastered surfaces of walls and applying two coats of cement base paint and all as specified and directed by Engr-in Charge. |
| 6 | M&L for preparation of old plastered surfaces of walls and applying one coat of distemper oil emulsion and all as specified and directed by Engr-in Charge. |
| 7 | M&L for preparation of old plastered surfaces of wallsand applying two coats oil bound distempercomplete all as directed. |
| 8 | M&L for preparation of old painted wooden surafces ofany description, not otherwisedescribed, over 10cm width or girthand applying one coat of synthetic enamel paint complete all as directed |
| 9 | M&L for preparation of old painted steel/iron surafces ofany description, not otherwisedescribed, over 10cm width or girthand applying two coats of synthetic enamel paint complete all as directed |
| 10 | Taking down cement plaster on bricks/ concrete surfacses including raking out joints, hacking for keys, scrubbing down with water etc complete all as directed. |
| 11 | M&L for rendering 15mm thick cement plaster on wall in CM (1:4) finished even and smooth without using extra cement complete all as specified and directed by Engr-in Charge. |
| 12 | M&L for rendering 10mm thick cement plaster on wall in CM (1:6) finished even and smooth without using extra cement complete all as specified and directed by Engr-in Charge. |
| 13 | M&L for rendering 10mm thick cement plaster on ceiling in CM (1:3) finished even and smooth without using extra cement complete all as specified and directed by Engr-in Charge. |
| 14 | M&L for preparation of newly plastered surfaces of walls and applying two coats ofoil emulsion distemperover a coat of primer complete all as specified. |
| 15 | M&L forpreparationof newly plastered surfaces of walls and applying three coats of white washing on walls complete all as specified and directed. |
| 16 | M&L for preparation of newly plastered surfaces of walls and applying two coats of Apex Ultima exterior emulsion paint over and including priming coat of exterior primer and 3mm thick Birla wall care putty completeall as specified and directed. |
| 17 | M&L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint over one coat of alkali resistant cement primer on walls complete all as specified and directed by Engr-in Charge. |
| 18 | M&L forpreparationof newly plastered surfaces of ceiling and applying three coats of white washing on ceilings complete all as specified and directed. |
| 19 | M&L for Guniting to existing RCC members after removing all dismantling loose concrete & preparations of surface, application of derusting chemical such as Dr FIXIT Rust Remover or equivalent, welding additional bars if found necessary, priming reinforcement bars with a coat of zink primer of coating not less than 40 mic, provision of bonding agent with bonding material like Dr FIXIT Bonding Agent and repair to external RCC structure with slurry tight and strong form work and short creat concrete of mixed 1:3:1 (one part of cement three part of coarse sand and one part of 10mm and down aggregate) of minimum 40mm thickness, curing the same for 14 days all a specified in IS 9012-1978 incl 10 mm thick rendering in CM1:4 finishing surfaces even and smooth complete allas directed. |
| 20 | Removing plants including roots by dismantaling of brick work PCC/RCC including necessary saffolding any type in any location/position i.e roof , parapet wall near pipes etc and applying acid after removeing roots for preventing the regrowth and making good of disturbed portion useing PCC (1:2:4) type B0 & 10mm thick plaster in CM 1:3 size of disturbed portion 150 x 150 x 200mm complete all as specified & directed by Engr - In - Charge. Note : Work to be carried out up to 05 storey bldg. |
| 21 | S&F 2 mm thick powder coated stainless steel 304 grade name plate of size 150 x 150 mm with engravedletters ( Size of letter exc 15 cm but nexc 25 cm and Qty nexc 05 nos, as per reqirement at site)and fixed with SS studs on walls including dismantling old existing name plate complete all as specified and directed |
| 22 | M&L for complete removal exsisting old treatment (old painted surfaces) finishing walls with Premium Acrylic Apex Ultima exteriror paint of required shade and applying two or more applied @ 1.67Ltrs/10 Sqm over and including priming coat of exterior @ 2.20Kg/10 Sqm all as specified and as directed bt Engr-in-charge. |