| 1 | Dismantling of AC sheet corrugated / Semi corrugated sheets in wall cladding or in roof covering complete all as specified and directed. |
| 2 | M&L for pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 3 | M&L for pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 4 | M&L for 6mm thick asbestos cement, corrugated or semi-corrugated sheets in roofs, walls etc complete all as specified and directed. |
| 5 | Dismantling of timber scantling in fillets, rails, posts, rafters, purlins, etc. any section complete all as specified and directed. |
| 6 | M & L for second class hard-wood in roof truss / timber scantlings clean sawn any description complete all as specified and directed |
| 7 | M & L for roof trusses, trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed. |
| 8 | Demolition of brick work or stone/boulder masonry built in cement mortar or cement limemortar including all quoins, aches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles all as spd and directed |
| 9 | M&L brickwork with old size fly ash bricks, straight or curved on plan exc. 6m mean radius built in 1:6 cement mortar complete all specified and directed. |
| 10 | M&L Brickwork old size with subclass‘B’ bricks, except brick straight orcurved on plan exc 6mmeanradius built in in CM (1:6) all as spd and directed |
| 11 | Taking down cement plaster on brick orstone walls, etc.including raking outjoints, hacking for key, scrubbing downwith water, etc. complete all as specified and directed. |
| 12 | M&L 12mm thick cement plaster on other than fair faces of brick surfaces or concrete surfaces in cm (1:6)newly surface even and smooth without using extra cement and necessary scaffolding all as spd and directed |
| 13 | M&L for rendering 12mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished even and smooth without using extra cementincluding scrubbing down with water etc complete all as specified and directed. |
| 14 | M & L for rendering 5mm thick on ceiling or concrete surfaces in cement mortar (1:3) finished the surface even and smooth withoutusing extra cement and necessary scaffolding complete all as spd and directed |
| 15 | M&L white washing three coats on ceiling surfaces including preparation of newly plastered untreated surfaces and necessary scaffolding all as spd and directed |
| 16 | M&L for applying 2.0 mm thick layer of wall care putty on external and internal wall surfacesincl rubbing down the surfaces with sand paper after getting dried all as directed to obtain a smooth & even surface complete all as spd and directed. |
| 17 | M & L applying one coat of distemper oil emulsion white or tinted on old decorated or undecorated wall surface including preparation ofsurfaces by washing rubbing down and stoping of distempered and painted surfaces complete all as specified. |
| 18 | M & L applying two coat of distemper oil emulsion white or tinted on newly decorated or undecorated wall surface including preparation ofsurfaces by washing rubbing down and stoping of distempered and painted surfaces complete all as specified. |
| 19 | M & L applying one coat of cement based paint on old decorated or undecorated wall, roof surface including preparation ofsurfaces by washing rubbing down and stoping of distempered and painted surfaces complete all as specified. |
| 20 | M&L two coats of cement base paint on new plastered wall surfaces over a coat of primer of any description including preparation of surfaces complete all as specified |
| 21 | M & L for cutting chases of hanging chajjas, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges ofsunshades, shelves, lintels, Chajja ( up to IIIrd floor) etc making good, cutting out exc 10cm and not exc 40cm girth in RCC chajjas in brick walls complete all as specified and as directed. |
| 22 | Demolition of reinforced cement concrete, (other than ground floors), shelves, chajjas, slabs and stair case similar work carefully and matching to adjoining disturbed surfaces complete all as specified and directed. |
| 23 | Demolition of reinforced cement concreteof any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 24 | M & L form work to edges of concrete rough finished surface flats, treads, breaks in floors, window cills, concrete railings, opening in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10 cm but n exc 20 cm wide complete all as specified and directed. |
| 25 | M & L for Form work to soffits of suspended slabs flat surface of concrete finishedrough surfaces of concrete not exceeding 200mm thick, complete all as specified and directed. |
| 26 | M & L formwork to chullah hoods, chajjas, trough and similar items including edges finished rough surfaces of concrete complete all as specified. |
| 27 | S&F TMT bars 10mm dia and over, cut to length, bent to shape required,including binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 28 | S&F TMT bars 5mm and over upto and including 10mm dia in stirrups, spacers and binders bent to shape required,including binding with mild steel wire (annealed) not less than .9mm dia complete all as specified and directed. |
| 29 | M&L RCC 1:2:4 type B1 using 20 mm graded aggregate as in slab, shelves and stair case etc.all as specified and directed. |
| 30 | M&L RCC 1:2:4 type B1 using 20 mm graded aggregate as in chajjas, facia and like all as specified and directed. |
| 31 | Dismantling of concrete by chiseling from RCC members like column , beam, parapet facia, chajja, ceiling,etc exposing the reinforcement without disturbing the reinforcement free from rust by sand blasting/using chemical, apply a coat of rustolin to remove rust and acralic polymer on old rusted reinforcement proving at places addl reinforcement welding with existing reinforcement as directed wherever required binding RCC 50 mmx 50 mm (10 mm gauge welded mesh ) & tack , securing with clips / linding wire, welding & provision guniting pressure 2.2 to 2.5 kg /sqm with admixer 1 cement 3.5 of sand of thickness 25 to 40 mm including stripping floating with wooden strippers for proper dimension control neccssary form work & scaffolding up to three storey and including height of head room complete surface of guniting to be finished fair with 10 mm thick plaster in cement mortar 1:4 with water proofing compound @ 200 ml every 50 kg of cement and applying two coat of Dr fixit /pidilite new coat ezee at interval of 8 hours cure for thesurfaces completeall as spd as directed. Water proofing Compound :-Dr Fixit (Pidiproof LW+ or pidicrete URP). |
| 32 | Demolition of cement concrete (un-reinforced), in any position and paving n.exc. 15 cm thickness (below or above ground level) including tile/ terrazzo floor complete all as specified and directed. |
| 33 | M & L for plain cement concrete 1:3:6typeC-1(using 20mm graded stone aggregate) as in plinth protection 75 mm thick finished even and fair including forming 10 mm wide joints at not exceeding 3 m distance between adjoining slabs shall not exceed 10 mm in thickness and shall be filled with bitumen mastic i.e. bitumen and sand in proportion 1:2 all as specified or as directed. |
| 34 | M & L for Providing water proofing treatment to RCC sunken slab as specified and directed as under:- (a) Cleaning the existing RCC sunken slab and vertical wall/RCC beam and hacking the surface. (b) 15mm thick plastering over the floor & vertical surface in CM 1:4, mixed with liquid water proofing compound @ 200ml per 50 kg of cement trowelled to even and smooth finish without using extra cement .(Water proofing compound shall be measured and paid separately). (c ) filling the sunken portion with water for 72 hrs and carring out the ponding test.(Any leakage /seapage noticed shall be repaired). (d) Applying two coats of elastomaric acrylic water proof coating Make: Dr. Fixit of pidiproof LW+ or equivalent per sqm in each coat with roller application.(Note: Each coat of elastomaric acrylic compound requires 6-8hrs to dry up itself second coat shall be applied on getting the first coat completely dried up.) |
| 35 | Supply only liquid waterproofing compound all as specified. Make : Dr. Fixit (pidiproof LW+) |
| 36 | M&L for cement concrete type E2 1:5:10 (40 mm graded aggregate) as in mass concrete complete all as specified and directed. |
| 37 | S&F 32mm dia GI pipe, medium grade as in spout pipe in sunken floor complete all as specified and directed. |
| 38 | M&L for plain cemet concrete 1:2:4 nominal mixed, type B0 using 12.5 mm graded aggregate as in levelling course, haunching, coping and similar works of over RCC roof surface including rounded or chamferred on edges etc all as specified and directed. |
| 39 | M&L for 15 mm thick rendering on fair faces of concrete surfaces of sunken/ roof/ parapet etc in CM 1:4 with water proofing compound concrete surface complete all as specified and directed.(NOTE:- WPC shall be measured and paid separatly) |
| 40 | Dismantling of roof terracing cement / brickconcrete (un-reinforced) and existing water proofing treatment of any thickness in any position and of any portion from top of roof of building, cleaning surface of roof with wire brush / mechanical brush and with water thoroughly to remove all dust / dirt and loose particles to expose base concrete roof slab and removal of rubbish / demolished material out of MD land complete all as specified. |
| 41 | M&L 25mm thick cement concrete type B1 1:2:4 using 20mm graded stone aggregate in floor finishes even and fair to receive floor tiles complete all as specified and directed. |
| 42 | (a) Supply and providing water proofing treatment with polyster based water waterproofing membrane standard water proofing membrane 3 mm thick, wt not less than 3.5 kg/ sqm having 10 years guarantee for water tightness all as specified and directed and described as under : (b) Prepartionof RCCroof surface and applying one coat of polymer modified bitumen 85/25 @ 1.2 Kg/Sqm over a coat of polymer primer @ 0.30 Kg/Sqm including cleaningsurface, all as per manufacture\"s specification complete all as specifiedand directed.(c) Supply & Providing APP based polyster based water waterproofing membraneminimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced/ torch application of membrane with 10 cm overlaps as required thereof, complete all as specifiedor as directed. Make :- IWL Hyperplas Polyster (M/S IWL), Super Thermolay (M/S STP Limited), Torch Shield AP by Pidilite Industries. |
| 43 | M & L for applying one coats of Bitumen based UV reflective and water proofing paint with aluminium finish over APP membrane and maximum coverage 8.00 Sqm per litre per coat on non assessible roof over APP membrance complete all as specified.Make “STP Ltd” Brand-“Super silver Shield” or equivalent quality |
| 44 | M & Lfor heat reflective weathering tile minimum 250 x 250 x 15 mm thick, fixed withneat cement slurry overlaid over 15mm thick screed bed in cementmortar 1:4 on roof top and joints shall be 4mm wide, sealed with 2 mm deep polysulphide compound (sealing compound) complete all as specified and directed. |
| 45 | M&L for Making of angle fillets 55mmx55mm on L Joints on the terraces periphery complete all as specified and directed. |
| 46 | Providing and Laying, Asian Paints Smartcare Damp Proof Ultra , a fibre reinforce elastomeric liquid applied water proofing membrane with resilient polymers having Sun Reflectivety Index (SRI) of 105. Forms a thick, seamless, durable membrane thus offering ultimate waterproofing with tensile strength of 2.9 mpa, elongation of more than 350% and resistant upto 10 bars of water pressure when executed in 2-3 coats. One coat of self priming of elastomeric waterproofing liquid ( dilution with water in the rationof 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than500 micron).Operation should be completed in all respect as per the direction of Engr-in-Charge.Insert roof tape on all the corners.Job shall be carried out by the authorised applicator assigned by M/S Asian Paint Ltd.The above waterproofing has warranty of 10 Years. Rates are inclusive for any storey of Bldgs and elctricity and water should be arrange by the contractor from nearby sources provided by the MES. |
| 47 | M&L for18-20mm thick Granite (Z- black/selected colour by GE) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. stone including grinding and polishing and 15mm screed bed in cement mortar 1:6 including dismantling of tiles, hearting etc complete all as specified. |
| 48 | M&L for 18-20mm thick machine cut pre polished kota stone slab in riser of steps skirting, dado and pillar,landing in single piece with round nosing with three numbers of serration using as front door steps, laid over cement screed and jointed with grey cement slurry mixed with pigment to match including rubbing & mirror polishing ding and inclucding 10mm thick cement plaster on brick surfaces or concrete surface in cm (1:4) finished even and rough as screedincluding dismantling of wall tile including cement mortar bedding complete all as spd and directed. |
| 49 | Rounding to edges of stone slabs one edge, such as in steps , cooking platform, and other similar situations complete all as specified and directed |
| 50 | Taking up or down 15 mm dia steel tubing and connections including cleaning for refixing or removal to store complete all as specified or as directed. |
| 51 | Taking up or down 20 mm dia steel tubing and connections including cleaning for refixing or removal to store complete all as specified or as directed. |
| 52 | Refixing 15mm dia old steel tubing and connections in new or old position(Walls,ceiling, floors, etc.) |
| 53 | Refixing 20mm dia old steel tubing and connections in new or old position(Walls,ceiling, floors, etc.) |
| 54 | S&F for 15mm bore galvanised steel water tubing with all fittings \"medium grade\" and fixed complete to wall and ceiling or laid in floors complete all as specified or as directed. |
| 55 | S&F for 20mm bore galvanised steel water tubing with all fittings \"medium grade\" and fixed complete to wall and ceiling or laid in floors complete all as specified or as directed. |
| 56 | Dismantling water tanks and removing to store capacity exc 250 and not exc. 500 litres complete all as specified and directed. |
| 57 | Dismantling water tanks and removing to store capacity exc 500 and not exc.1000 litres complete all as specified and directed. |
| 58 | S & F 500 ltrs capacity rotational moulded polythylene triple layered water storage tanks white in colour (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed. |
| 59 | S&F Rotational moulded polyethylenetriple layered water storage tanks of 1000 Litre capacity white in colour (cylinderical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-Icomplete all as specified and directed. |
| 60 | M&L for tankCleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etccapacity of tank exc 250 Ltr but n exc 500 Ltrs complete all as specified and firected. |
| 61 | S&F in repairs 15mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed (Minimum weight 210 gms complete all asspecified or as directed. |
| 62 | S&Fin repairs 20mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all asspecified or as directed. |
| 63 | Taking up or down AC/PVC rain water pipe, soil/waste/vent pipe of any size with fittings etc. complete all as specified and directed. |
| 64 | S & F PVC (SWR) 110 mm diasoil waste or rainwater drainage pipes single socketed in any length with rubber ring joint laid in floor or fixed on wall all as specified or as directed. |
| 65 | S & FPVC (SWR) 110 mmbore bends all as specified or as directed. |
| 66 | S&F in repairPVC (SWR) multi floor trap with grating including jointing with solvent cement floor trap 75 mm dia outlet plain including jointing to waste pipe fixed in cement concrete (1:2:4), type B-1 complete all as specified and as directed. |
| 67 | S&F PVC (SWR) 75 mm bore pipes single socketed in any length with rubber ring joints fixed to wall and floorwith necessary fitting complete all as specified and as directed. |
| 68 | S&F in repairs PVC 110mm bore Y-Junction piece single (equal or unequal) ordinary or inverted (spigot or shocket type) or with parallel branches with oval access door complete all as specified and directed. |
| 69 | S&F in repairsPVC 110mm bore branch piece single (equal or unequal) ordinary or inverted (spigot or shocket type) or with parallel branches with oval access door complete all as specified and directed. |
| 70 | S&F in repairs PVC 75 mm bore branch piece single (equal or unequal) ordinary or inverted (spigot or shocket type) or with parallel branches with oval access door complete all as specified and directed. |
| 71 | S&F in repairs 110mm bore PVC bends (any radius) diminishing pieces or tapers (larger bore mesured) with oval access door complete all as specified and directed. |
| 72 | S&F 75mm bore PVC bends (any radius) diminishing pieces or tapers (larger bore mesured) with oval access door complete all as specified and directed. |
| 73 | S&F in repairs 75 mm bore PVC cowl complete all as specified. |
| 74 | S&F in repairs for Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays for 75mm dia pipe, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed. |
| 75 | S&F in repairs for Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays for 110mm dia pipe, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed. |
| 76 | S & F in repairs Galvanized mild steel wire cloth, 0.56 mm dia of wire and average width of aperture 1.18 mm and fixed with tinned stacks, or galvanized wire staples complete all as specified and directed. |
| 77 | Hacking out old broken glass (any thickness, size, quality or description) from wooden or metal frames including punching or drilling out old glazing pins/spring clips and providing and fixing new ones or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed. |
| 78 | S & F Sheet glass 5.5 mm thick, ordinary quality and glazing with oil putty or wooden/aluminium beads n exceeding 0.5 Sqm in each pane glazed with putty or fixed with beads complete all as specified and directed. |
| 79 | S & F Figured glass, 4.0 mm thick, ordinary quality and glazing with oil putty or wooden beads n exceeding 0.5 Sqm in each pane glazed with putty or fixed with beads complete all as specified and directed. |
| 80 | S & F plain glass, 4.0 mm thick, ordinary quality and glazing with oil putty or wooden beads n exceeding 0.5 Sqm in each pane glazed with putty or fixed with beads complete all as specified and directed. |
| 81 | M&L for PCC 1:4:8 type D-2 75mm thick (40mm thick stone agg) as in sub base of floor complete all specified and directed. |
| 82 | M&L for PCC 1:3:6 type C-2100mm thick (20mm thick stone agg) as in sub base of floor complete all specified and directed. |
| 83 | M&L for Machine pressed precast conctete interlocking paver block with gray cement and pigment any shape and size confirming to IS 15658-2006 of 60 mm thickness M-40 Gradeover25mm thicksand cushioning including watering and consolidation complete all specified and directed. |
| 84 | M& Lfor Chequered cement concrete with grey cement and pigment tiles 30cm x 30cm x 20mm thick, set, jointed and pointed in neat cement slurry in floors over 20mm thick screed bed in cement mortar 1:6 complete all as specified and directed. |
| 85 | Notes:-Tenderers may note that amount as given in schedule of credit will be deducted from the total amount to worked out the net contract sum at the time of Acceptance of tender. |