Tender For Spl Repair To Bldg No Sm 04 Of Stn Hq Patiala; 1 Dismantling asbestos cement(corrugated or semi corrugated, etc) sheets in roof covering complete all as specified.Note: The rates includes rates of scaffolding to work at a height of double story . Contractor shall take all necessary safety precautions alongwith insurance cover to his workmen before commencement of work. Unit rates quoted shall deemed to be inclusive of all such factors and nothing extra including compensation to workmen in case of accident any manner is payable on this account. 2 Dismantling timber scantling 40Sqcm and over in section in any position in unframed work as in rafters, purlins etcNote: The rates includes rates of scaffolding to work at a height of double story . Contractor shall take all necessary safety precautions alongwith insurance cover to his workmen before commencement of work. Unit rates quoted shall deemed to be inclusive of all such factors and nothing extra including compensation to workmen in case of accident any manner is payable on this account. 3 Dismantling wrought iron or mild steel work of any description not oth-erwise provided for.Note: The rates includes rates of scaffolding to work at a height of double story . Contractor shall take all necessary safety precautions alongwith insurance cover to his workmen before commencement of work. Unit rates quoted shall deemed to be inclusive of all such factors and nothing extra including compensation to workmen in case of accident any manner is payable on this account. 4 Demolition of cement concrete of any description and in any position not otherwise specially provided for complete all as directed. 5 M&L for PCC 1:4:8 type D-2 using 40mm graded stone aggt in foundation, filling, mass concrete complet all as specified and directed. 6 M & L for cement concrete 1:3:6 type C2 using (40mm graded stone aggregate) as in post holes/foundationfilling mass concrete complete all as specified 7 S&F mild steel plates (plain or chequered) channels,squarecutor notched (ordinaryand countersunk) forming holes,with riveted, bolted or welded attachment conforming Fe- 290 Gde -E-165 complete all as specified and directed. 8 S & F prepainted galvalume aluminium zinc coating GI base corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / clading to wall, fixed with self tapping screws Complete all as specified and directed.(Note : Corrugation shape and colour of sheet shall be approvedby GE) Note: The rates includes rates of scaffolding to work at a height of double story . Contractor shall take all necessary safety precautions alongwith insurance cover to his workmen before commencement of work. Unit rates quoted shall deemed to be inclusive of all such factors and nothing extra including compensation to workmen in case of accident any manner is payable on this account. 9 S & F prepainted galvalume aluminium zinc coating GI base plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / clading to wall, ridges, hips, valley gutter, fixed with self tapping screws Complete all as specified and directed.Note : Corrugation shape and colour of sheet shall be approvedby GE) The rates includes rates of scaffolding to work at a height of double story . Contractor shall take all necessary safety precautions alongwith insurance cover to his workmen before commencement of work. Unit rates quoted shall deemed to be inclusive of all such factors and nothing extra including compensation to workmen in case of accident any manner is payable on this account. 10 S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. 11 Excavating in post holes (or similar holes) as in hard/dense soil each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, thick complete all as directed 12 S&F Steel work of square/round pipe as in post/purlin/rafter including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 Corrugation shape and colour of sheet shall be approvedby GE) Note:The rates includes rates of scaffolding to work at a height of double story . Contractor shall take all necessary safety precautions alongwith insurance cover to his workmen before commencement of work. Unit rates quoted shall deemed to be inclusive of all such factors and nothing extra including compensation to workmen incase of accident any manner is payable on this account. 13 S&F framed work such as ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 of square pipe/flat/angle/ISMB complete all as specified and directed. 14 M&L Preparation of oldsurfaces of wood or wood based materials of any description not other wise described, over 10cm width or girth and applying one coat of synthetic enamel paint,complete all as specified and directed. 15 M&L for preparation of new steel surfaces exc 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed. 16 M&L preparation of old painted steel surfaces exc 10cm width or girth and applying one coats of synthetic enamel paintcomplete all as specified and directed. 17 Taking dpwn and refixing of wooden partition wall of any type and description complete all as specified and directed by Engr-in-Charge 18 Dismantling wall panelling and ceiling boards any thickness including cover fillets complete all as specified and directed. 19 S&F Tee grid suspension system of size 600 mm x 600 mm type-1 made out of rolled steel framed hot dipped galvanised steel zinc coated of not less than 120 gm/Sqm, main runner 0.3 mm thick of section24 mm x 33 mm crross runner 0.30 mm thick of section 24 mm x 25 mm, wall angle shall be 0.63 mm thick of section 24 mm x 24 mm grid shall be suspended by 4 mm dia adjustable quick fit hanger rod, system exposed portion shall be pre painted polyester coated in off whitee/white in colour complete with material, fixing, jointing etc., with Coloured textured designer ceiling board 4mm thick of size 595 x 595 mm fixing with screws/clips complete all as per manufacturers instructions and direction and directed by Engr-in-Charge. 20 Fixing only Tee grid suspension system of size 600 mm x 600 mm including ceiling boards of any description obtained from dismantling with existingmain runner and cross runner. Grid shall be suspended with existing hanger rod complete all as specified and directed by Engr-in-Charge. 21 S&F of hollow PVC Wall Lining consisting of 5mm thick, wood grain printed PVC sheet inclusive of solvent cement and fixing at site on walls as per specifications and drawing complete all as specified and directed by Engr-in-Charge. 22 Taking down chowkats or frame with shutters(without taking off shutters from the frame) exc 1.5 sqm and n exc 4.0 sqm each complete all as specified and directed. 23 Taking down chowkats or frame with shutters ( without taking off shutters from the frame) n.exc 1.5 sqm each complete all as specified and directed. 24 Taking down shutters and refixing in the same opening of any description exc 1 sqm and n exc 2 sqm each complete all as specified and directed. 25 Taking down shutters and refixing in the same opening of any description n exc 1 each complete all as specified and directed. 26 S&F powder coated Anodised aluminium door /window frame and shutters/fixed partition including necessary joining cleats, glazing clips, ruber neoprene packing in each door, anodised aluminum snap beading screws etc. complete all as specified and directed. Note : Minimum thickness of powder coating shall be 50 micron. 27 S&F 12mm thick high density fibre board pre-laminated on both sides (water proof) below & above middle/ lock rail in powder coated aluminium doors and to be fixed with and including EPDM gasket to render the glazing, air and water tight etc with aluminium beads 20mm size with and complete all as specified and directed. 28 S&F brass Mortice lock of 2 livers,vertical type, size 100 mm 29 S&F aluminium anodised 150mm long Powder coated barrel tower boltof extruded section 30 S & F aluminium anodised butt hinges 100 mm size powder coated of medium weight complete all as specified and directed 31 S&F aluminium anodised 100mm long Powder coated handle D type complete all as specified and directed. 32 M&L for aluminium anodised 150mm long Powder coated handle(American type) type complete all as specified and directed. 33 S&F Door closer hydraulically of aluminium (extruded section) bodyregulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg complete all as specified and directed. 34 S&F in repairs Door closer hydraulically of aluminium (extruded section) bodyregulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg complete all as specified and directed. 35 S&FStainless steel wire cloth 0.36mm normal dia of wire and average width of aparture 1.40mm and fixed with tinned tacks or galvanised wire stapples complete all as specified and directed. 36 M&L for 5 mm thick tinted glass but exc 0.5 sq. m in each pane complete all as specified and directed. 37 Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds and steel window frame glazed with putty or fixed with beads complete all as specified and as directed by the Engineer-in-Charge. 38 M&L for 5 mm thick tinded glass not exc 0.5 sq. m in each pane complete all as specified and directed. 39 Demolition ofBrick work or stone/boulder masonry, built in cementmortar or cement lime mortar including all quions, arches, pillars etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. 40 M&L Baroda Green13-15 mm thick laid and jointed with grey cement slurry incl rubbing and polishing with granite finishover and including 15 mm thick CM 1:4 screed bed complete all as specified and directed.(Note: All exposed side of stone slab to be rounding) 41 M&L for brick work with sub class B bricks built in CM (1:6) straight orcurved on plan & exc 6 m mean radius with old size bricks complete all as specified and directed. 42 Demolition of cement concrete is reinforced (reinforcement cut as required to facilitate demolition)Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and directed. 43 Taking down cement or lime plaster of any description from stone or brick walls etc including raking out joints, hacking for key scrubbing down with water and disposing off the rubbish complete all as specified or directed . 44 Material & labourfor 15mm thick rendering on surfaces other than fair faces of brick/concrete surfaces in CM (1:6) and finished even and smooth without using extra cement. 45 Material & labourfor 15mm thick rendering on fair faces of brick/ concrete surfaces in CM (1:4) finished even and smooth without using extra cement mixed with water proofing compound.( Note-Water proofing compound should bemesured and paid separately ) 46 Supply only liquid water proofing compound 47 M&L rendering 5 mm thick in CM (1:3) on concrete surfaces of ceilling ,finished the surfaces even and fair without using extra cement complete all as specified. 48 M&L for Complete removal of existing treatment and applying two coat of interior emulsion paint by using roller to wall/ceiling surfaces over and including a coat of interior primer and wall care putty of 0.5mm to 1mm thick complete all as specified. 49 M&L for preparation of new plastered surfaces and applying two coat of interior emulsion paint by using roller to wall/ceiling surfaces over and including a coat of interior primer and wall care putty of 0.5mm to 1mm thick complete all as specified. 50 M&L for Complete removal of existing treatment and applying two coat of exterior emulsion paint by using roller to external walls/RCC surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc surfaces over and including a coat of exterior primer and wall care putty of 0.5mm to 1mm thick complete all as specified. 51 M&L for preparation of new plastered surfaces and applying two coat of exterior emulsion paint by using roller to external walls/RCC surfaces/soffits of chajjas/roof projections /cantilevers /balcony etc surfaces over and including a coat of exterior primer and wall care putty of 0.5mm to 1mm thick complete all as specified. 52 M&L machine cut Kota stone slab 18 to 20 mm thick as in flooring or treads of step incl half round moulding over and including screed bed 15 mm thick in CM (1:6) laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab including cutting, rubbing and polishing complete all as specified. 53 M&L machine cut Kota stone slab 18 to 20 mm thick as in riser to step including 10 mm thick rendringin CM (1:4) laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab including cutting, rubbing and polishing complete all as specified. 54 M&L for grinding and Mirror polishing on marble/ granite/Kota stone/ stone work where ever required to give high glossy finish complete all as specified and directed. 55 Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. 56 M&L for Non Skid ceramic colouredtiles 7mm to 8mm thick, (square or rectangular) area of each tile exc 0.11 Sqm but n. exc 0.18 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 15mm thick screed bed in CM 1:6 all as specified. 57 M&L forVirified Ceramic tiles 10 mm thick (square/ rectangular) polished and light shade, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM 1:6 complete all as specified. 58 All as per item No 57 above but on skirting/vertical surfaces incl 10mm thick renderingin CM 1:4 complete as specified. 59 M&L for 25mm thick PCC (1:2:4) type B0 using 12.5mm graded stone agg as in Top surfacesfinished even and fair complete all as specified and directed. 60 M&L for Glazed ceramic tiles coloured (600x300mm) x 7-8mm thick of pattern as in dado/skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 10mm thick rendering in CM (1:4) complete all as spd 61 Taking up or downof 15 mm bore steel tubing and connections, including cleaning for re-fixing or removal to store complete all as specified and directed. 62 Taking up or down of 20 mm bore steel tubing and connections, including cleaning for re-fixing or removal to store complete all as specified and directed. 63 Supplying and laying of CPVC pipes of outer dia 16 mm, SDR 11 & Plain CPVC SDR 11 fittings in wall/floorincluding all necessary fittings (Elbow, Tee, Socket, Reducer, Bushing, Step over bends, End cap, End Plugs etc)complete all as specified. 64 Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good,cutting not exc 10 cm in girth on brick walls complete all as specified and directed 65 Supplying and laying of CPVC pipes of outer dia 20 mm, SDR 11 & Plain CPVC SDR 11 fittings in wall/floor including all necessary fittings (Elbow, Tee, Socket, Reducer, Bushing, Step over bends, End cap, End Plugs etc) complete all as specified. 66 Dismantling of water tanks exc 1000 & n exc 2000 ltr capacity & removing to store all as directed by the Engr-in-Charge. 67 S&F rotational moulded PVC water storage tank cylinderical, vertical with closed top of 1000 ltrs capacity, hoisted and fixed in position with and including PTMT float valve 20mm dia and making connections for inlet and outlet complete all as specified and directed. 68 S&F in repairstop cock /Angle cock 15mm cast copper alloy,screwed down,withchromium plated fancy typehigh pressure screwed both ends for iron pipe or for union complete all as specified and directed. 69 S&F in repair bib taps (long body) 15mm bore of cast copper alloy chromium plated fancy type, screwed for iron pipe or for brass ferrule & fixed complete all as specified and directed. 70 S & F central hole basin mixer with popup waste system and 450 mm long braided hoses, fancy type, cast copper alloy, with capstan heads, chrmium plated screwed down, high pressure with long screwed shanks and fly nuts, screwed for 15mm bore of iron pipe complete all as specified and directed by Engr-in-Charge. 71 S&F in repair 15mm borestop cock fancy type, chromium plated with long shank and cup (concealed type) screwed down, fancy typehigh pressure screwed both ends for iron pipe or for union complete all as specified and directed. 72 S&F in repair vitreous china wash basin, white flat back screwed down for iron pipe waste pipe, brackets and cutting for and pinning in ends of brackets or errecting stand but excl taps, chain and plug and including waste pipe complete all as specified and directed. 73 S&F in repair Water Closet ( Squatt pattern) Orissa pattern size 580 mm x 440mm, white, with P or S integral foot rest complete including provision of PCC 1:2:4 B-1 as in bedding, complete all as specified and directed. 74 S&F in repair Vitreous China wash down water closet pan (pedestal pattern), white(excluding fixing flushing cistern and flush pipe) complete all as specified and directed. 75 S&F Plastic water closet seat, black, closed pattern with recessed bottom and cover and mild steel chromium plated or aluminised hinging deviceSeat and cover for pedestal pan complete all as specified and directed. 76 S&F in repair Vitreous China Urinal, half stall type, whiteincluding flat back ,white with grating and union for discharge pipe including waste pipe etc. complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement complete all as specified and directed by Engr-in-charge.. 77 Supplying and fixing in repairs Vitreous china urinal partition white of size 310mmx700mm, complete all as specified and directed by Engineer-in-Charge 78 S&F Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimumweight 60gms) complete all as specified and directed. 79 S&F in repair 10 litre capacity PVC flushing cistern, valve less symphonic type low level or high level with inlet, ball valve float chains pull and brackets complete with flush pipe 32mm dia complete all as specified and directed. 80 S&F in repair PVC connection 600mm long of dia 15mm complete complete all as specified and directed. 81 S&F in repair soap dish of 1mm thick stainless steel box type fixed with screws of size 150mmX150mmX100mm complete all as specified and directed. 82 S&F in repairs decorative type Mirror of 5 to 6 mm thick of any size with bevelled edge and fixed with stainless steel studs/ brackets/ plugs/ connector/ spacers/ screws etc chrome finish complete fixed in position all as specified and directed 83 S&F in repair 125mm size brass chromium plated shower rose fixing with 15mm dia pipe complete all as specified and directed. 84 S&F low density polyethylene pipe of pressure rating 6kg/sqcm pipe 50mm borein any length laid in trenches or floor complete all as specified and directed. 85 S&F in repair tubular towel rail 20mm dia D type and 60cm long including brackets fancy type brass chromium plated complete all as specified and directed. 86 S&F in repair grating PTMT square of size 150mm complete all as specified and directed. 87 Demolition and breaking up drain pipes (salt glazed stone ware,AC or Reinforced concrete) set in cement mortar internal dia of pipe up to 100mm 88 S&F in repair 75 mmboreUPVC Pipes (SCH-40) in any length fixed to walls /laid in floor with and including rubber ring joint and MS clamps . 89 S&F in repair 110 mmbore UPVC Pipes (SCH-40) in any length fixed to walls /laid on floor with and including rubber ring joint and MS clamps complete all as specified and directed. 90 S&F UPVC bends 75 mm(any radius), fixed in repairs 91 S&F UPVC bends 110 mm(any radius),fixed in repairs 92 S&F UPVCEqual Tee 110 mm bore 93 S&F UPVC Equal Tee 75 mm bore 94 S&F UPVC cowl 75 mm bore 95 S&F UPVC cowl 110 mm bore 96 S&F in repair 110 mmbore PVC (SWR ) PIPE in any length fixed to walls and floor with and including rubber ring joint and MS clamps .. 97 S&F PVC (SWR) bends 110 mm bore 98 S & F in repairs Gun-metal, globe or gate valves 20mm bore, with iron wheel head, screwed both ends for iron pipe andfixed complete all as specified and directed 99 Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 25mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed. 100 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete 101 M&L for 75mm thhick PCC (1:4:8) type D2 using 40mm graded stone aggregate as in Sub base finished even and rough complete all as specified and directed. 102 S&F in repairs 25 mm dia fancy type drapary curtain rods with and including suitable fancy type brackets to both ends as required fixed in repair complete all as spd and directed. 103 Dismantling of brick tiles or terracing tiles single layers laid bedded and pointed in any mortar on roofs complete all as specified and directed. 104 Removing of Mud in roofs, any thickness, including plastering and leeping (whether full thicknesremoved or only a part thereof) 105 M&L for wire brushing and cleaning roof top surface of cement concrete, including flashings and junction of parapets, etc. complete all as specified and directed. 106 M&L for cement concrete 1:3:6 type C1 using 20 mm graded aggregate as in padding over roof minimum thickness of khurra as 25 mm to maintain a slope of 1:40 complete all as specified and directed. 107 M&L for 10 mm thick rendering in CM 1:4 incl mixing with WPC(WPC shall be paid separately) complete all as specified and directed. 108 M&L Providing and laying3mm thick APP (Atactic Polyproplene Polymer) modifiedprefabricated five layer, weightnot less than 3.0 Kg/Sqm water proofingmembrane black finished, reinforced with non-woven polyster matt (wt not less than 150g/sqm) make as approvedover andincludinga coat of bitumen primer @ 0.40 ltr/sq.m by the samemembrane manufacturer ofdensity 0.87 to 0.89 Kg/Ltr at 25 degree C temperature and viscosity 70 - 160 cps , 3mm thick 5 layered APP membrane shall be laid using butane torch and sealing alljoints etc after the surface complete as per standard practice as per manufacturers instructionscomplete all as specified and directed. 109 M&L for two coats of aluminium paint over APP water proofing membrane complete all as specified and directed. 110 M&L for PCC of grade 1:2:4 type b0 (Nominal Mix) using 12.50mm graded aggregate mixed with WPC as manufacturer instruction laid in slope 1:2 including making PCC gola at the junction of walls/beams and slab for smooth turning of membrane as directed by Engr-in-Charge 111 M&L for rendering 15mm thick in CM (1:4) on wall/floor surfaces of sunken floor finished even and smooth using WPC as per manufacturers instruction and brushing with cement slurry @ 0.25 kgs of cement per sqm complete all as specified and directed. 112 M&L for applying a coat of paving bitumen 80/100 penetration @ 1.5 Kgs/sqm on plastered & concrete surfaces complete all as specified and directed. 113 S&F for 25mm bore GI medium grade pipe 450mm long spout complete all as specified and directed. 114 M&L for lean concrcete type D2 (1:4:8) using broken brick aggregate fo filling sunken portion complete all as specified and directed. 115 M&L for efflorescence treatment to walls complete in all respect with following procedure :- (a) Taking down existing plaster , washing /rubbing down loose particles from wall surfaces /Rinse the surface with clean water and pointing the joints in cement mortor 1:3 complete all as specified and directed.(b) The bricks so pointed shall be cleaned of all dust or deposit using brush and applying two coats of smartcare damp proof coating 2K of make asian paints , Damp protec 2K of JK maxx paints or equivalent in Burger paints/Nerolac paints. (c) ThereafterM&L for plastering 15mm thick over the treated surface shall be done with 1:4 cement sand plaster using WPC. Note : Thecomplete item shall be gotexecuted through the authorised applicator of manufacturer only all as directed by Engr-in-charge.Applicator shall be got approved by GE before execution of work. 116 Takingdown carefully existing points wiring on surface conduit/concealed conduit including conduit from surface and expect conduit in concealed wiring for light/fan/socket/power/bell from wall & roof along with fitting and fixtures such as switches, sockets, ceiling roses, batten holders, unserviceable light fittings, pieces of wires, gutties, conduit, wooden boards etcremoving materials to store for keeping in safe custody of contractor for which the credit has been considered under schedule of creditand making good the disturbed portion of all floor, ceiling etc all as specified and directed. 117 M & L for Point wiring with 1.5 sqmm PVC insulated and unsheathed FRLSH single core multistranded copper conductor for one light/fan/bell point in and including NEW PVC rigid non metallic concealed conduit 19/20 mm dia, medium duty, ISI Marked to be terminated in pressed steel terminal boxes with PVC modular top cover plates of suitable size for mounting of modular type switches/sockets/regulators including 1.5 sqmm PVC insulated and unsheathed FRLSH single core multistranded copper earth continuity conductor controlled by one switch and/or one regulator complete including cutting chases and making good the surfaces in CM 1:3 and finishing the surface as per existing treatment all as specified and directed by Engr-in-charge.Notes: (i) Cost of Pressed steel Terminal Boxes and modular Top cover plate shall be included in point wiring. (ii) Wiring shall be done as per colour code in IS for phase, neutral and earth.(iii)-Cost of Eye/bottle thimblesused for connection in switches/sockets & MCBs in DBs shall deemed to be included in the unit rate quoted for this item. 118 All as per Sl item No 117.00 above herein before but one socket out let 5 pins 5 Amp on the same board with other switches complete all as specified and directed. 119 All as per Sl item No 117.00 above herein before but for one socket out let 5 pins 5 Amp on independent board complete all as specified and directed. 120 All as per item No.117.00 herein beforebut 2.5 Sqmm PVC insulated and unsheathed FRLSH single core multistranded copper conductor incl 2.5 Sqmm PVC insulated and unsheathed FRLSHcopperearth wire for switch socket combination 3 pin 15 amps on independent board. 121 S & F in replacement of Modularswitch1 way, 6 Amps, 1 module, 230 volts complete all as specified. 122 S & F in replacement of Modularswitch1 way, 16 Amps, 1 module, 230 volts complete all as specified. 123 S & F in replacement of Modular socket 5 pin 6 Amps, 2 module 230 volts complete all as specified. 124 S & F in replacement of Modularsocket 5 pin 6 &16 Amps, combination type2 module complete all as specified. 125 S & F in replacement of Modular Fan regulator step type, 120 watts, 2 module complete fixed as in repair all as specified. 126 S & F in replacement of ceiling rose surface bakelite surface 65 x 50mm3 terminals all as specified & directed 127 S & F in replacement of New generation energy saving and environmental friendly long life LED building security light 1x35 watts made up of pressure die cast alluminium housing with high power LED as light source and lense embedded PC cover having TOP OPENING separate driver compartment with IP65 protection and impact resistance of IK07,with all accessories including suitable bracket with 32mm bore light grade GI pipe bemd to shape, including MS clamp of size of required size and PVC cable 1.5 Sqmm twincore from ceiling rose to light fittings complete all as specified and directed by Engineer-in-charge. 128 M & L for Sub main wiring with two single core 6.0 Sqmm PVC insulated and unsheathed FRLSH,stranded copper conductor cable drawn through PVC concealed conduit 25 mm dia including 6.0 Sqmm PVC insulated unsheathed FRLSH stranded copper conductor cable as earth wire all as specified and directed by Engineer-in-charge. Note 1:- 2(two) Runs of 6.00 Sqmm Copper conductor cable, 1 Run of PVC conduit & 1 Run of 6.00 Sqmm Copper conductor Earth wire shall be measured as one unit)Note 2 :(i) Rate quoted for this items shall be inclusive of the cost of (i) Rigid non-metallic PVC conduit of 25 mm dia with tees, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc.(ii) Cutting chases, pinning in making good to facing where required and pointing in cement mortar 1:3 to match the existing surfaces and cutting not exc.10 cm girth . (iii) Including taking out/down existing unserviceable sub main wiring. 129 S & F MCCB, 4 Pole, 125 A, 25 KA for fixing in DB including proper thimble connection, thermal and magnetic release protectioncomplete all as specified and directed by Engineer-in-charge. 130 Supply and fix in replacement of epoxy power coated MCCBdistribution box double door VTPN 4 way vertical type AC 415 V with IP 43 protection for MCBs alongwith provision of MCCB as incomer with commen bus-bar at incoming end of outgoing MCBs grouted/ flush to wall, complete all as specified by Engineer-in-charge. (Note :- MCCB will be measured and paid under seperate item) (i) Cost of Eye/bottle thimblesused for connection MCBs in DBs shall deemed to be included in unit rate quoted for this items, (ii) Electric wiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for Earth.(iii) connection of theMCCBs/ MCBs with cableshall be made through appropriate size pin /bottle type thimble -properly crimped. all the vacant holes of the DB shall be provided with blank plates of appropriate size complete all as specified and directed by Engr-in-charge. 131 Supply and fix in replacement of Sheet metal enclosure 8 ways double door for DBs when MCBs areto be used 240,volts including 200 Amps standard bus bar of suitable size and common neutral link allflush mounting type, drilling holes for incoming and out going cables with IP43 protection complete all as specified & directed byEngr-in-charge. 132 S & F in replacement of MCB, single pole 240 volts 6 to 32 Amp capacity for fixing in DB’s including proper thimble connections complete all as specified and directed by Engineer-in-Charge. 133 Supply and fix in replacement of MCB , SPN, 240 Volts ,40-63 amp for fixing in DBs ofincluding proper thimble connections complete all as specified and directed by Engineer-in-Charge. 134 M & L for Sub main wiring with two single core 4.0 Sqmm PVC insulated and unsheathed FRLSH,stranded copper conductor cable drawn through PVC concealed conduit 25 mm dia including 4 Sqmm PVC insulated unsheathed FRLSH stranded copper conductor cable as earth wire all as specified and directed by Engineer-in-charge. Note 1:- 2 Runsof 4.00 Sqmm Copper conductor cable, 1 Run of PVC conduit & 1 Runof 4.00 Sqm Copper conductor Earth wire shall be measured as one unit) Note2 : Rate quoted for this items shall be inclusive of the cost of(i) Rigid non-metallic PVC conduit of 25 mm dia withtees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc.(ii) Cutting chases, pinning in making good to facing where required and pointing in cement mortar 1:3 to match the existing surfaces, cutting not exc.10 cm girth . (iii) Taking out/down existing unserviceable sub main wiring. 135 M & L in replacement of UNSV Earthing complete with galvanized iron earth plate electrode of size 600x600x6.0mm , buried directly in ground (earth pit not less than 2.25 mtrs below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level, connected to galvanized earth lead wire 4.0 mm dia by means of bolts , nuts , check nuts and galvanized iron or steel including earth work in any type of soil, charcoal salt 15 cm around the earth plate 20 mm dia watering pipe medium grade 1.70 mtr long with a plug at top, GI protection pipe light grade 15 mm dia from earth pit to main board including PCC pit in cement concrete 1:2:4 along with CI frame and cover 10mm thick duly hinged to CI frame as shown in the electrical plate No3 of SSR 2009 part 1 specification at page 497. 136 S & F in replacement Tube light fitting Self Ballasted LED Batten. Extruded Thermoplastic body with PC Diffuser in squareLED Batten 18/20W 6500Kof capacity ,20 watt,4 ft long incl 3 core flexible wire 0.5 sqmm copper cable all as specified and directed by Engr-in-charge. 137 S & F in replacement Tube light fitting Self Ballasted LED Batten. Extruded Thermoplastic body with PC Diffuser in squareLED Batten 9/10W 6500Kof capacity ,10 watt,2 ft long incl 3 core flexible wire 0.5 sqmm copper cable all as specified and directed by Engr-in-charge. 138 Supply and fix surface/recess mounted LED luminaire 36 watt warm white 3000 K suitable for gridd celling cutout dimensions: 2x2 Ft. incl connecting with twin core copper wire from ceiling rose to fitting, Fixture size: (LxWxH) in (595x595x65) mm incl lamp and driver all as specified & directed. 139 XLPE Insulated ,screened, PVC bedded, galvanized steel wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core supplied& laid in replacement complete all as specified& directedby Engineer-in-Charge. 140 Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of cables including getting out in any kind of soil complete all as specified and directed. 141 Returning filling in including spreading, levelling, and well ramming, in layers not exceeding 25 cm thick each layer of any kind of soil. 142 Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding1.5 mtr above the starting point complete all as specified and directed. 143 Material and labour for sand cushioning for cables 8 cm below the cable and 15 cm abovewith dry river sand in trenches for cushioningof underground cable line including spreading, leveling, well ramming completed all as specified and directed. 144 Cutting of hardstanding floor/wall for laying of cable including matching with suface by using cement concrete 1:2:4 type B-1 all as specified and directed. 145 Supplying & laying factory made unreinforced Precast concrete cable coversclass LV type 1, flat, Size 250x150x40mm laid in trenches as protection to cables completeall as directed by Engr-in-Charge 146 Material and labour for replacement of GI tubing light grade 40 mm borefor passing through cables under the floor ,along the wall or along the pole complete all as specified and directed. 147 Taking down and refixing of ceiling fan after supply and replacement of rubber reel, round cover plate of size 6 inch of ceiling fan complete with MS split clamp two Nos, nuts and bolts complete all as specifiedand directed by Engr-in-charge. 148 Taking down and refixing of wall mounting fan after supply and replacement of rubber seal, complete with MS split clamp two Nos, nuts and bolts complete all as specifiedand directed by Engr-in-charge. 149 Supply and fix Exhaust fan AC single phase 230/240 v of size 250 mm sweep 900 rpm Engineering thermoplastic body, high efficiency motor, dynamically balanced blade for better performance and corrosion-resistant powder coated metallic finish including frame and Louver complete all as specified and directedby Engineer-in-Charge. 150 Taking down of existing Split type AC of Cap 2.0/1.5 TR complete with Indoor and Outdoor unit from existing location with all Electric Connection, connected Voltage Stabilizers ( if any) and all Refrigerant Pipes and matching the existing disturbed surface area and depositing to AGE E/M store. 151 Refixing ofSplit type AC of Cap 2.0/1.5 TR complete with Indoor and Outdoor unit to location with all Electric Connection, connected Voltage Stabilizers ( if any) and all Refrigerant Pipes and matching the existing disturbed surface area with the existing complete as directed by EIC. Note: Split AC 1.5/2 Tonto be transported back to the site of installation by Contractor from AGE E/M store. 152 Supply and fix ofcopper pipe heavy duty of size 5/8 complete all as directed by Engr-in-charge. 153 Supply and fix ofcopper pipe heavy duty of size 3/8 complete all as directed by Engr-in-charge. 154 Supply and fixing pipe insulation for copper pipe of size 5/8 and 3/8 complete all as directed by Engr-in-charge. 155 Taking down of existing Window AC of Cap 2.0/1.5 TR complete with connected Voltage Stabilizers ( if any) from existing location with all Electric Connectionandmatching the existing disturbed surface area and submitting to AGE E/m store.Note: Cost of transportation has been catered in this item. 156 Refixing of window AC 1.5 ton with connected nuts and bolts along with stabilizers to new location as specified by the EIC . Window AC 1.5 Tonto be transported back to the site of installation by Contractor from AGE E/M store. Note: Cost of transportation from AGE E/M back to site of installationhas been catered in this item 157 Supply and fixingsingle pole and neutralenclosure with a two pin and earth plug and socket complete with MCB SPN 32 Amps, complete all as specified and as directed by Engineer-in-charge. 158 Taking downGeyser 25 ltr capacity and depositing to AGE E/M Store and Refixing of Geyser after replacement of Old PVC connection pipes with new PVC pipe ( Set of 2 ), new Anchor bolts, new back platefor fixing of geysers as directed by EIC.