| 1 | Credit for: |
| 2 | Unserviciable M.S. sections & pipes/GI Pipes/Fiitings etc. |
| 3 | Dismantling lean cement concrete of sunken portion of toilet, bath and W.C. with flooring on top, taking out all the material and stacking same at specified place within 50 M lead, taking out sanitary fixtures viz. w.c. pan, P/S/Nahani trap gently, checking & repairing joints of drainage pipes and replacing damaged fittings/fixtures to make the system leakproof including refixing same in order and refilling lean concrete back to the sunken portion after necessary water proofing treatment therein and disposal of rubbish & unserviceabl material complete as per direction of the Engineer-in-charge.(Note: water proofing treatment, new fittings & fixtures if required and flooring on top shall be paid separately). |
| 4 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : |
| 5 | 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size derived fro natural resources) |
| 6 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 7 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 8 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: |
| 9 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 10 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: |
| 11 | 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 12 | Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets : |
| 13 | 20 mm dia (heavy type) |
| 14 | Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete : |
| 15 | 250x16 mm |
| 16 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : |
| 17 | 250x10 mm |
| 18 | 150x10 mm |
| 19 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : |
| 20 | 100 mm |
| 21 | Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : |
| 22 | 100X58X1.90 mm |
| 23 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. |
| 24 | Twin rubber stopper |
| 25 | Providing and fixing PVC rigid foam sheet 1mm thick on existing door shutters (bathroom and W.C. doors) using synthetic rubber based adhesive. |
| 26 | Providing and fixing galvanised wire mesh of average width of aperture 1.40 mm and nominal diameter of wire 0.63 mm in wooden/steel door and windows including wooden fillets/MS flats with nails or nut & bolts etc. complete wherever required and as per direction of the Engineer-in-charge. |
| 27 | Arranging welding machine at site for welding of Broken steel components such as Handels, fastners, hinges, grills etc. as and where required as per the direction of Engineer-in-Charge. (rate includes labour & transportation of machine at site). |
| 28 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 29 | 40 mm thick with 20 mm nominal size stone aggregate |
| 30 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc.,., complete. |
| 31 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : |
| 32 | (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. |
| 33 | (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. |
| 34 | (The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.) |
| 35 | Drilling suitable holes across the RCC beams, columns upto 30 Cm width, with power driven drill machine of required size bit to introduce 20 mm dia nominal bore GI spout pipe to sunken portion including fixing in position with epoxy resin anchor grout of approved make and cost of pipes & necessary scaffolding/jhoola required for work all complete as per direction of the Engineer-in-charge. |
| 36 | 12 mm cement plaster of mix : |
| 37 | 1:6 (1 cement: 6 coarse sand) |
| 38 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground , all complete as per directions of Engineer-In-Charge. |
| 39 | With cement mortar 1:4 (1cement: 4 coarse sand). |
| 40 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: |
| 41 | Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm). |
| 42 | Raking out joints in lime or cement mortar and preparing the surface for re-pointing or replastering including disposal of rubbish to the dumping ground, all complete as per directions of Engineer-In-Charge. |
| 43 | Flush pointing with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement for flat tile bricks on top of mud phaska : |
| 44 | With F.P.S. brick tiles |
| 45 | Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge. |
| 46 | Closing all leakages in G.I. pipes etc. by replacing damaged fittings such as tee, elbow, sockets, nipple etc. complete as per direction of the Engineer-in-charge. |
| 47 | Providing and fixing low level cistern internal fitting kit (syphon) including checking for proper working etc. complete. |
| 48 | Complete removal of huge Peepal trees grown up on external walls of building and spreading over two storey height including taking out all the branches and roots from the masonary, chhajjas, pipes, roofs comletely and repair to affected parts of building by brick work, plain C.C. of mix 1:2:4 or cement mortar 1:2 (1 cement: 2 fine sand) wherever required, and realigning vertical drainage pipes including cost of required mortar, CC, making arrangement for jhula, ladders, ropes etc. complete as per direction of the Engineer-in-charge. |
| 49 | Uprooting of undesired grown up plants over wall and filling the hole after uprooting of plant roots with plain C.C. of mix 1:2:4 or cement mortar 1:2 (1 cement: 2 fine sand) whichever required including making arrangement for jhula, ladders, ropes etc. complete as per direction of the Engineer-in-charge. |
| 50 | On walls above first floor level at where major scaffolding/Jhula is required. |
| 51 | Repairing of PVC cistern including providing and fixing minor fittings such as screws, washer, broken/missing parts of body and making in good working order complete as per direction of the Engineer-in-charge. |
| 52 | Providing and applying cement slurry @ 0.50 Kg/Sqm mixed with tapcrete @ 0.15 Kg/Sqm on gola, khurra, roof etc. after cleaning the surface by brush, filling crackes/joints with cement mortar 1:2 (1 cement: 2 fine sand) mixed with tapcrete 30% by weight of cement etc. complete as per direction of the Engineer-in-charge. |
| 53 | Providing and fixing white vitreous china water closet squatting pan (Indian type) : |
| 54 | Orissa pattern W.C. pan of size 580x440 mm |
| 55 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. |
| 56 | 10 litre capacity - White |
| 57 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 58 | Semi rigid pipe |
| 59 | 32 mm dia |
| 60 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : |
| 61 | Rectangular shape 453x357 mm |
| 62 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall |
| 63 | 15 mm nominal outer dia. Pipes. |
| 64 | 20 mm nominal outer dia. Pipes. |
| 65 | Providing and fixing CPVC gate valves of approved brand and manufacture for CPVC pipe lines. |
| 66 | 25mm size |
| 67 | Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws including excavation, refilling the earth or cutting of wall and making good the same complete wherever required : |
| 68 | 20 mm nominal bore. |
| 69 | 25 mm nominal bore. |
| 70 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 71 | Providing and fixing covers for PVC water storage tanks with necessary MS / PVC clamps |
| 72 | For 500 litres capacity tanks |
| 73 | Providing and fixing PTMT bib cock of approved quality and colour. |
| 74 | 15mm nominal bore, 86 mm long. Weighing not less than 88 gms. |
| 75 | Providing and fixing PTMT pillar cock of approved quality and colour . |
| 76 | 15mm nominal bore, 107 mm long. Weighing not less than 110 gms. |
| 77 | Providing and fixing PTMT grating of approved quality and colour. |
| 78 | Circular type. |
| 79 | 100 mm nominal dia. |
| 80 | 125 mm nominal dia with 25 mm waste hole. |
| 81 | Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. |
| 82 | 20 mm nominal bore, 120 mm long. Weighing not less than 198 gms. |
| 83 | Providing and fixing PTMT angle stop cock 15 mm nominal bore. Weighing not less than 85 gms. |
| 84 | Providing and fixing PTMT swivelling shower, 15mm nominal bore. Weighing not less than 40 gms. |
| 85 | Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour. |
| 86 | 15 mm nominal bore with 45 cm length. |
| 87 | Removal of chokage in P,S or Nahani trap by cleaning the same with water and rodding in associated drainage pipe i/c opening and refixing the door of T joints if rquired complete as per direction of Engineer-in-charge. |
| 88 | Cleening of all roof top, terrace i/c mumty, staircase, khurra with rain water pipe, under of water tank etc. by removing silt, fungi, grass, leaves etc. and uprooting all the unwanted plants, bushes and rank vagetation etc. including disposal of malba outside the compound as per direction of the Engineer-in-charge. |
| 89 | Cleaning of choked water supply G.I. pipe line with pressure machine for proper supply of water i/c opening and refixing of bends, sockets etc. whichever necessary complete as per direction of the Engineer-in-charge. |
| 90 | Repairs to steel windows by welding broken members, replacing damaged/broken hinges etc. including applying oil/grease etc complete as directed by Engineer-in-charge. (Hire charges of welding plant at site shall be paid separately) |