| 1 | B/R PORTIONSurface excavation not exceeding 30cm deep and average 15cm deep and getting out in any type of soil, complete all as specified and directed. |
| 2 | Removal of excavated material to a distance not exc.50 m and depositing where directed at a level not exceeding 1.5 mtr above starting point, complete all as specified and directed. |
| 3 | Rolling and consolidating formation surfaces in cutting with power roller exc 8 tonne and not exc 12 tonne, complete all as specified and directed. |
| 4 | M&L for 100mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base to flooring/path etc, complete all as specified and directed. |
| 5 | M&L for Sand filling under floors or in foundation including required watering and consolidation complete all as specified and directed. |
| 6 | M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS-15658-2006 of 80mm thickness M-40 Grade,laid jointed pointed with grey cement and no pigments,complete all as specified and directed by Engr-in-Charge. Note: The sample shall be got approved by GE before bulk procurement & lot shall be got tested independently by the GE. |
| 7 | M&L for Cement concrete (1:2:4) type B-1, using 20mm graded stone aggregate as in plinth courses, string courses, lacing courses, copings, bed block, kneelers, apex stones, bed plates, roof kerbs round or chamfered on edges, water troughs and the like including weathering, slightly rounded or chamfered angles and throatings etc including necessary form work complete all as specified and directed by Engineer-in-Charge. |
| 8 | Excavation over area not exceeding 1.5m deep and and getting out in hard/dense soil, complete all as specified and directed. |
| 9 | M&L for Hard core of broken stone/boulders of gauge n exc 63mm deposited, spread and levelled in layers n exc 15cm thick watered and rammed to a true surface, complete all as specified and directed. |
| 10 | M&L for Cement concrete work in pavement/hard-standing of flexural strength 40 kg/per square centimetre in field using 400 kg of cement per cubic metre, thickness of concrete 25 cm or less, as in path and finished the surface even and smooth without using extra cement, complete all as specified and directed. |
| 11 | Forming 12mm thick expansion joint and filled with pre-formed bituminous filler and top 30mm primed & sealed with sealing compound grade \"B\" for 100 mm thick cement concrete slab, complete all as specified and directed. |
| 12 | Forming Construction joint 30mm deep x 10mm wide filled with sealing compound grade \"A\", complete all as specified and directed. |
| 13 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth in any type of soil for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc.not exc 10 sqm on plan, complete all as specified and directed by Engineer-in-charge. |
| 14 | M&L for PCC 1:4:8, type D-2, using 40 mm graded stone aggregate as in foundation filling and mass concrete, incl necessary form work complete all as specified and as directed. |
| 15 | M&L for brick workwith sub class ‘B’ bricks, straight or curved on plan exc. 6 m mean radius, built in cement mortar 1:6, complete, all as specified and directed. |
| 16 | M&L for Concrete bed to drain pipes including packing under and haunching against the sides of pipes of 150mm bore after they are laid and tested in PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) complete all as specified and directed. |
| 17 | M&L for 150 mm bore salt glazed stone ware (SGSW) drain pipes, grade ‘A’ laid in trenches and jointed as specified and all as directed by Engr-in-Charge. |
| 18 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm, in any type of soil, complete all as specified and as directed.Note : Punned down thickness shall be measured |
| 19 | M&L 15 mm thick rendering in cement mortar 1:4 on fair faces of brick work, surface finished even & smooth without using extra cement incl mixing of water proofing admixture @ 200 ml/50 kg of cement or as per manufacturer\"s instruction, complete all as specified and directed. |
| 20 | Supply only Liquid water proofing compound, complete all as specified and directed. |
| 21 | S&F Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, binding spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia, complete all as specified and as directed. |
| 22 | M&L for Precast cement concrete (1:2:4) using 20mm graded crushed stone aggregate as in landings, cover slab (for manholes etc), chullah hoods, chajjas, water troughs, shelves and similar articles with plain fair faces including chamfers, weatherings, throating etc. and setting in cement mortar (1:4) including necessary form work complete all as specified and directed by Engineer-in-Charge. |
| 23 | M&L for Soakage Well3.00 m dia X 4.30 meffective depth with foundation in PCC 1:4:8 walls of honeycombed masonary with top ring of M25 concrete, including intercepting chamber and screen chamber made of brick masonary in CM 1:6, RCC cover slab M25/ SFRC cover interconneting pipes of RCC/ DWC complete all as shown in drawing No. CE/TD-1585/2021 sheet 1/4 to 4/4 and as specified and directed. |
| 24 | M&L foron site LLDPE septic tankfor 30 users designed to carry sewage and sullage water, incl excavation in any type of soil, with 100 mm thick PCC in 1:4:8 in foundation, vent shaft, all required connections etc including dismentling taking out of existing deteriorated/degraded septic tank and disposed off the same outside defence land, complete all as specified and as directed. |
| 25 | Dismantling of timber scantling 40sqcm and over in section unframed work,as in any position, complete all as specified. |
| 26 | Taking down roof trusses, coupled rafters or trussed beams, clear span exc 4 m but not exc 8 m, complete all as specified and directed. |
| 27 | S&F rolled mild steel works as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam,tee,angle, channel or flat sections) including distance pieces, cleats etc Fe 290(Gde E 165), complete all as specified and directed. |
| 28 | M&L for Rolled mild steel sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connected plate conforming to Fe 410W (Gde E-250), quality \"A\" complete all as specified and directed. |
| 29 | M&L for Mild steel screw bolts exceeding 16mm but not exceeding 20mm dia at neck, machine made, with hexagonal or square heads at one end and screwed the other, or screwed both ends; each screwed and to be fitted with washers and one hexagonal or square nut exceeding 22.5cm and not exceeding 30cm long complete all as specified and directed. |
| 30 | Dismantling of plain or corrugated steel sheeting, any gauge, thickness including Nainital or similar pattern roof covering, complete all as specified and directed. |
| 31 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa, 150 GSM as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 32 | S&F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa, 150 GSM as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 33 | Demolition of brick or stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work, complete all as specified and directed. |
| 34 | M&L for Walling of random rubble stone masonry brought upto course, well bonded, bedded and solidly hearted, built in cement mortar (1:6), complete all as specified and directed. |
| 35 | All as per srl item No. 34Above but except stone , complete all as specified and directed. |
| 36 | M&L for PCC 1:2:4, type B-1, using 20mm graded stone aggregate as in anchoring hold fast, bed plate, coping, filling of chowkhat frames etc complete all as specified and as directed. |
| 37 | M&L for preparation of new or previously untreated steel or iron surfaces of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint over and incl a coat of red oxide primer, complete all as specified and directed. |
| 38 | Taking down cement plaster from brick or stone walls hacking for keys & scrubbing down with water including raking out joints, complete all as specified and directed. |
| 39 | M&L 15 mm thick rendering in cement mortar 1:4 on other than fair faces of bricks surface or stone masonry surface or on one side of lathing,finished even & smooth without using extra cement using, complete all as specified and directed . |
| 40 | M&L 15 mm thick rendering in cement mortar 1:6 on other than fair faces of bricks surface or stone masonry surface or on one side of lathing,finished even & smooth without using extra cement using, complete all as specified and directed . |
| 41 | Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc. complete all as specified and directed by Engineer-in-Charge. |
| 42 | Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level), complete all as specified and directed . |
| 43 | M&L for 50 mm thick cement concrete (1:3:6), type C-1 using 20mm graded stone aggregate as in floors, hard standing etc and laid in alternate bays complete and finished the even & fair and providings joints through out the thickness of plinth protection filed with mastic filling comprising one part of 01 bitumen 85/25 grade and three part of sand by weight all as specified and directed |
| 44 | M&L for 20-25mm thick Machine cut Kota stone slab flooring, bedded and jointed with grey cement slurry and pointed with grey cement mixed with pigment to match the shade of Kota stone slab as approved by GE, laid over and including screed bed or bedding layer of mortar 20mm thick in Cement Mortar (1:6) including cutting, grinding and mirror polishing complete, all as specified and directed. |
| 45 | M&L for kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar with grey cement slurry mixed with pigment tomatch the shade of the slab including rubbing and polishing & over and incl 10mm thick rendering in CM 1:4, complete all as specified & directed. |
| 46 | M&L for 25mm thick PCC 1:2:4, type B-0, using 12.5mm graded stone aggregate, as in sub base of flooring, finished even and rough to receive top layer, complete all as specified and as directed. |
| 47 | Taking down chowkhat or frame exc 1.5 Sqm but n exc 4 Sqm each with shutters (without taking of shutter from the frames ), complete all as specified and as directed. |
| 48 | Taking down chowkhat or frame not exc 1.5 Sqm each with shutters (without taking of shutter from the frames), complete all as specified and as directed. |
| 49 | M&L for Pressed steel frames for doors for size 125 x 60mmwith one or more rebates including necessary fixing lugs, hinges, lock strike plate,etc., complete all as specified and as directed. |
| 50 | S&F 35 mm thick 2nd class hardwood flush shutters, solid core construction, with particle core and plywood face panels, commercial type on both sides, complete all as specified and as directed. |
| 51 | M&L for 35mm thick 2nd class hardwood glazed and skeleton shutters, open rebated and prepared to receive glass, gauge etc, (with sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc sizes of members of shutters as specified in SSR part-I, section 8, clause 8.24 (a) complete all as specifed. |
| 52 | S&F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified. |
| 53 | S&F mild steel work conforming to Fe-290 (Gde E-165) as in grills, gratings etc. with ends of bars shouldered and/ or rivetted or forged into spikes; framed guard bars, and similar works complete all as specfied and directed. |
| 54 | S & F 150mm long aluminium, anodised, barrel tower bolts of extruded section and fixed, complete all as specified and direcetd. |
| 55 | S& F 150 mm long aluminium handles, cast type, anodised and fixed, complete all as specified and direcetd. |
| 56 | S&F Aluminium alloy, anodised, sliding door bolt 300 mm with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or castaluminium alloy and fixed, complete all as specified and direcetd. |
| 57 | S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads in square not exc 0.5mm Sqm each pane complete all as specified and directed |
| 58 | S&F galvanised mild steel wire cloth 0.56 nominal dia of wire and average width of aparture 1.18 mm and fixed with tinned tacks or galvanised wire staples, complete all as specified and directed. |
| 59 | M&L for preparing of new or previously untreated surfaces of wood of any description not otherwise describedover 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed. |
| 60 | S&F in repair mild steel helical door spring 300mm long stove enamelled, ordinary rat tail rod pattern springs including roller and roller plate fixing with screws to wooden frames or with welding to steel frames, complete complete all as specified and directed. |
| 61 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for, complete all as specified and as directed. |
| 62 | M&L for RCC nominal mix 1:2:4, type, B-0 (using 12.5mm graded crushed stone aggregate), as in Beams, cantilevers, chajja, bressummers, lintels over 1.5m span, complete all as specified and directed. |
| 63 | Form work to sides and soffits of floor or roof beams, beam haunchings , lintels, cantilevers, shelves including supports, overhangs etc and similar works rough finished complete all as specified & directed |
| 64 | Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) any thickness including cover fillets complete all as specified and directed. |
| 65 | S&F Anodised aluminium snap grid frame work for false ceiling of size 600 x 600mm with hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means ofceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long 6mm thick calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600mm x 600mm grid complete all as specified and as directed. |
| 66 | Demolition of Concrete unreinforced of any description and in any position not otherwise specifically provided for, complete all as specified and directed. |
| 67 | M&L for Cement concrete 1:3:6 type C-2 (using 40 mm graded stone aggregate) in surface channels and drains, complete all as specified and directed. |
| 68 | Extra for forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement complete all as specified. |
| 69 | E&M PORTION:-Taking down carefully copper/ aluminium unserviceable/ perished point wiring (light, fan, socket or power complete including fixture and fittings such as switches, ceiling roses, pandents, regulators, sockets, light fittings,removing material from site for taking credit etc and making good disturbed surfaces of wall, floors, complete all as specifiecd and directed. |
| 70 | M&L for point wiring with two single core 1.5 Sqmm (nominal cross section area) FRLS PVC insulated unsheathed multistranded copper conductor cableand one single core 1.5 Sqmm(nominal cross section area) FRLS PVC insulated unsheathed multistranded copper conductor cable as earth continuity to common earth and connecting to earth dolly running in and including PVC casing & caping (ISI marked) of suitable size with PVC boards of appropriate sizes and all requisite accessories such as PVC elbow, Tee, collars, bends etc. with PVC terminals box & cover for mounting swtches, sockets, fan regulator etc for mounting switches, sockets, fan regulators etc complete all as specified and as directed for the following :- |
| 71 | One light/fan point controlled by one way switch 6 Amp complete all as specified and directed. |
| 72 | One 3/5 pin socket outlet 6 amp on same board complete all as specified and directed. |
| 73 | One 3/5 pin socket outlet 6 amp independent board complete all as specified and directed. |
| 74 | All as per srl item No 70 here in before but for one 3 pin socket outlet 16/20 Amp independent with two single core 2.5 Sqmm size cable as phase & neutral and one single core 2.5 Sqmm as in continuous earth wire complete all as specified and directed. |
| 75 | S&F ceiling rose, 3 terminal, surface bakelite 65 mm x 50mm, PVC/poly carbonate, insulated body, complete all as specified and directed. |
| 76 | S&F switch piano flush type 6 Amp single pole one way, (ISI marked), complete all as specified and directed. |
| 77 | S&F socket outlet2 in 1, 3 pin, 6 Amp flush type universal, complete all as specified and directed. |
| 78 | S&F switch socket combination 5 pin, 6 Amp flush type universal, complete all as specified and directed. |
| 79 | S&F switch socket combination outlet2 in 1, 6 pin, 6 & 16 Amps flush type universal, complete all as specified and directed. |
| 80 | S&F Lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings, complete all as specified and directed. |
| 81 | S&F in repair LED inverter lamp,CDL, 12 watt, B22 base, complete all as specified and directed. |
| 82 | S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. for 1200 / 1400mm sweep, complete all as specified and directed. |
| 83 | Supply and fixing in repair LED batten 1x 20W, with square profile and polycarbonate channel,incl LED tube light connecting up with with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 84 | Supply and fixing in repair LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver including suitable bracket fixed to wall/ pole complete with IP 65/66 protection complete all as specified and directed. |
| 85 | S&F in repair sheet metal enclosure for DBs, SPN double door (IP43), 8 ways with 200 amps rated bus bar suitable for 240 volts, AC, 50 Hz, including connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning complete all as specified and directed. |
| 86 | S&F in repairMCBSPN 40-63 amps 415 volts 10 KA \"C\" series, complete all as specified and directed. |
| 87 | S&F in repair MCBsingle pole 6 to 32 amps 240 volts 10 KA \"C\" series complete all as specified and directed. |
| 88 | S&F Earthing complete with galvanized steel earth plate electrode 60cmx 60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to galvanized iron wire 4.0mm dia by means of bolts, nuts and washers of galvanized iron or steel, protected by GI light grade pipe 15mm bore including GI light grade water pipe 20mm dia with funnel all as shown in electric plate No. 3 of 2009 SSR Pt-I and testing complete including earth work in any type of soil, PCC 1:2:4 type B-1 as in earthing pit and cover 50mm thick reinforced with 6mm dia MS round bar @ 10cm C/C both way and MS frame, common salt, charcoal and testing on completion including dismantling unsv earthing, complete all as specified and directed. |
| 89 | S&F 1100 volts grade heavy duty cable PVC insulated solid aluminium conductor served with PVC tape and over all PVC sheathed in service connections suspended by insulating hangers not more than 1 m apart including 4mm dia GI suspension wire, one twin core cable flat or circular of size 16 Sqmm 2 core& including taking down old old unsv service cable connection, complete all as specified and directed. |