}

Tender For Addition/Alteration To Bldg No. P-214, JcoS Mess, OrS Mess And Provision Of Vehicle Parking Shed For Mt Vehicles At Awantipur Garrison Under Ge 861 Ews, Anantnag-Jammu And Kashmir

Military Engineer Services has published Tender For Addition/Alteration To Bldg No. P-214, JcoS Mess, OrS Mess And Provision Of Vehicle Parking Shed For Mt Vehicles At Awantipur Garrison Under Ge 861 Ews. Submission Date for this Tender is 27-06-2025. Building Work Tenders in Anantnag Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

49384620
Corrigendum : Tender For Addition/Alteration To Bldg No. P-214, JcoS Mess, OrS Mess And Provision Of Vehicle Parking Shed For Mt Vehicles At Awantipur Garrison Under Ge 861 Ews
Tender
Indian
Jammu And Kashmir
Anantnag
27-06-2025

Tender Details

Tender For Addition/Alteration To Bldg No. P-214, JcoS Mess, OrS Mess And Provision Of Vehicle Parking Shed For Mt Vehicles At Awantipur Garrison Under Ge 861 Ews; 1 Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed by Engineer-in-Charge. 2 Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and as directed by Engineer-in-Charge. 3 Dismantling cast iron/mild steel/structural steel work of any description complete all as specified and as directed by Engineer-in-Charge. 4 Dismantling reinforced cement concrete as in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and as directed by Engineer-in-Charge. 5 Taking down Chowkhats or frames not exc. 1.5 sq. m each with shutters (without taking off shutters from the frames) complete all as specified and as directed by Engineer-in-Charge. 6 Taking down Chowkhats or frames exc. 1.5 and n exc 4.0 sq. m each with shutters (without taking off shutters from the frames) complete all as specified and as directed by Engineer-in-Charge. 7 Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store/ credit and rubbish off the premises complete all as specified and as directed by Engineer-in-Charge. 8 Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed by Engineer-in-Charge. 9 Dismantling of Stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar complete all as specified and directed by Engineer-In-Charge. 10 M&L for Earth work in excavation by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5 m, for all types of soil complete all as specified and as directed by Engineer-in-Charge. 11 Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, in hard / dense soil, complete all as specified and as directed by Engineer-in-Charge. 12 Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard / dense soil complete all as specified and as directed by Engineer-in-Charge. 13 Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in hard / dense soil complete all as specified and as directed by Engineer-in-Charge. 14 M&L for plain cement concrete (1:4:8) type D2 (using 40mm graded crushed stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed by Engineer-in-Charge. 15 M&L for Cement concrete (1:3:6) type C2 (using 40mm graded crushed stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed complete all as specified and as directed by Engineer-in-Charge. 16 M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:4) complete all as specified and as directed by Engineer-in-Charge. 17 M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar (1:4) complete all as specified and directed by Engineer-in-Charge. 18 M&L for Rendering 10mm thick on fair faces of brick work or concrete surfaces built in cement mortar (1:4) surface should be finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge. 19 M&L Rendering 10mm thick on other than fair faces of brick work or concrete surfaces of wall with cement mortar (1:6) and surface should be finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge. 20 M&L for Rendering 15mm thick on other than fair faces of brick work or concrete surfaces built in cement mortar (1:6) surface should be finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge. 21 M&L for 15mm thick Rendering on fair faces or other than fair faces of brick work or concrete surfaces with cement mortar (1:4) and surfaces to be finished even and smooth (without using extra cement)complete all as specified and as directed by Engineer-in-Charge. 22 S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS-1161- 1979 grade St.-240 complete all as specified and as directed by Engineer-in-Charge. 23 S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. complete all as specified and as directed by Engineer-in-Charge. 24 S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour havingtensilestrength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and as directed by Engineer-in-Charge. 25 S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour havingtensilestrength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and as directed by Engineer-in-Charge. 26 M&L for 100mm thick PCC (1:4:8) type D2 (using 40mm graded crushed stone aggregate) as in sub base of floor finishes complete all as specified and as directed by Engineer-in-Charge. 27 M&L for 100mm thick cement concrete (1:3:6) type C2 (using 40mm graded crushed stone aggregate) as in sub base of floor finishes finished complete all as specified and as directed by Engineer-in-Charge. 28 M&L for Non - skid coloured joint free Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed or bedding layer in cement mortar (1:4) complete all as specified and as directed by Engineer-in-Charge. 29 M&L for coloured Non - skid Ceramic joint free tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including 15mm thick screed bed or bedding layer of cement mortar (1:4) complete all as specified and as directed by Engineer-in-Charge. 30 M&L for Coloured Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10mm thick screed bed or bedding in cement mortar (1:4) complete all as specified and as directed by Engineer-in-Charge. 31 M&L for Coloured Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick screed bed or bedding in cement mortar (1:4) complete all as specified and as directed by Engineer-in-Charge. 32 M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 100 mm thickness M-50 Grade with grey cement and no pigment complete all as specified and as directed by Engineer-in-Charge. 33 S&F 2nd class hard wood Plain fillets square, rectangular or triangular in section, clean sawn, bull nosed, splayed, chamfered or rounded on one edge or face secured with nails or brads exc 13 Sqcm and n exc 25 sqcm complete all as specified and directed by Engineer-in-Charge. 34 S&F 2nd class hard wood Plain fillets square, rectangular or triangular in section, clean sawn, bull nosed, splayed, chamfered or rounded on one edge or face secured with nails or brads exc 06 Sqcm and n exc 13 sqcm complete all as specified and directed by Engineer-in-Charge. 35 S&F 2nd class hard wood Plain fillets. square, rectangular or triangular in section, clean sawn, bull nosed, splayed, chamfered or rounded on one edge or face secured with nails or brads n exc 03 sqcm complete all as specified and directed by Engineer-in-Charge. 36 M&L for 4mm thick Veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on one face; fixed with screws to timber frame work in ceiling complete all as specified and as directed by Engineer-in-Charge. 37 M&L for 4mm thick Veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on one faces; fixed with screws to timber frame work in Wall complete all as specified and as directed by Engineer-in-Charge. 38 S&F powder coated Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. (minimum thickness of powder coating 50 micron) complete all as specified and as directed by Engineer-in-Charge. 39 S&F powder coated Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified (minimum thickness of powder coating 50 micron) complete all as specified and as directed by Engineer-in-Charge. 40 S&F 2nd class hardwood Plain, solid, straight chowkhats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed complete all as specified and as directed by Engineer-in-Charge. 41 S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm wood grain printed PVC sheet used instead of Plain colour PVC sheet & edges will be painted to match with printed sheet PVC sheet reinforced with M.S. Square tube, supplying & fixing in opening as per specification & drawing complete all as specified and as directed by Engineer-in-Charge. 42 S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded wood grain printed PVC sheet used instead of Plain colour PVC sheet & 5mm thick x15mm wide PVC sheet beading used inside stiles and rails and decorative PVC beading of 10mm x 10mm used instead of exposed portion of PVC sheet beading. PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and as directed by Engineer-in-Charge. 43 S&F factory made 35mm thick framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and as directed by Engineer-in-Charge. 44 S&F 30mm thick 2nd class hardwood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkhats complete all as specified and as directed by Engineer-in-Charge. 45 S&F 30mm thick 2nd class hardwood Glazed and skeleton shutters, for window shutter open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkhats complete all as specified and as directed by Engineer-in-Charge. 46 S&F 30mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed by Engineer-in-Charge. 47 S&F Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and as directed by Engineer-in-Charge. 48 S&F 4.8mm thick Sheet glass, ordinary quality and glazing with oil putty in square exc 0.5 sq. m in each pane complete all as specified and as directed by Engineer-in-Charge. 49 S&F 4.00mm thick Sheet glass, ordinary quality and glazing with oil putty in square exc 0.5 sq. m in each pane complete all as specified and as directed by Engineer-in-Charge. 50 S&F 200mm long Brass barrel tower bolts, with cast or sheet barrel and rolled or cast bolts and fixed complete all as specified and as directed by Engineer-in-Charge. 51 S&F 125mm long Aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and as directed by Engineer-in-Charge. 52 S&F 100mm long Brass barrel tower bolts, with cast or sheet barrel and rolled or cast bolts and fixed complete all as specified and as directed by Engineer-in-Charge. 53 S&F 300 mm long Brass, sliding door bolt with sand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts and fixed complete all as specified and as directed by Engineer-in-Charge. 54 S&F 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed by engineer-in-charge. 55 S&F 100 mm long Butt hinges, Medium weight, cold rolled mild steel, and fixed complete all as specified and as directed by Engineer-in-Charge. 56 S&F 75 mm long Butt hinges, Medium weight, cold rolled mild steel, and fixed complete all as specified and as directed by Engineer-in-Charge. 57 S&F 100 mm long Butt hinges, extruded brass, with mild steel hinge pin, bright polished and fixed, type B-11 complete all as specified and as directed by Engineer-in-Charge. 58 S&F 75 mm long Butt hinges, extruded brass, with mild steel hinge pin, bright polished and fixed, type B-12 complete all as specified and as directed by Engineer-in-Charge. 59 S&F 150 mm long Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and as directed by Engineer-in-Charge. 60 S&F 100 mm long Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and as directed by Engineer-in-Charge. 61 S&F 150 mm long Extruded brass handles, fabricated type polished complete all as specified and as directed by Engineer-in-Charge. 62 S&F 100 mm long Extruded brass handles, fabricated type polished complete all as specified and as directed by Engineer-in-Charge. 63 S&F 300mm long, mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and as directed by Engineer-in-Charge. 64 S&F 300mm long, Brass ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and as directed by Engineer-in-Charge. 65 S&F in repairs Harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc. complete all as specified and as directed by Engineer-in-Charge. 66 M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed by Engineer-in-Charge. 67 M&L for Hard core of gauge exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface complete all as specified and directed by Engineer-in-Charge. 68 M&L for Hard core of broken stone or boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed by Engineer-in-Charge. 69 M&L including preparation of newly wooden surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed by Engineer-in-Charge. 70 M&L for 75mm thick cement concrete (1:3:6) type C2 (using 40mm graded crushed stone aggregate) as in sub base of floor finishes complete all as specified and as directed by Engineer-in-Charge. 71 M&L for 75mm thick cement concrete (1:4:8) Type D2 (Using 40mm graded crushed stone aggregate) as in plinth protection finished surface even and smooth (without using extra cement) complete all as specified and as directed by Engineer-in-Charge. 72 M&L including preparation of newly steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified and as directed by Engineer-in-Charge. 73 M&L including preparation of newly plastered Surfaces plain or moulded, n exc 10cm width or girth when unconnected with other painting or when painted in a different tint over a coat of priming paint plaster complete all as specified and as directed by Engineer-in-Charge. 74 M&L including preparation of newely plastered surfaces of wall and applying two coats of cement based paint over a coat of alkali resistant primer coat complete all as specified and as directed by Engineer-in-Charge. 75 M&L including preparation of newly plastered surface of wall and applying three coats of white wash over coat of chalk white primer complete all as specified and as directed by Engineer-in-Charge. 76 S&F in repairs 15mm dia Tubes, medium grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by Engineer-in-Charge. 77 S&F in repairs 20mm dia Tubes, medium grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by Engineer-in-Charge. 78 S&F 15mm dia Tubes, medium grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by Engineer-in-Charge. 79 S&F 20mm dia Tubes, medium grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by Engineer-in-Charge. 80 S&F Vitreous china premium/ 1st quality wash down water closet floor mounted EWC white/ ivory/off white (closed pattern including all necessary accessories like rag bolts/ gel gasket etc. (inlcuding 10 ltr capacity PVC flushing cistern & flush pipe) complete in all respect all as specified. complete all as specified and as directed by Engineer-in-Charge. 81 M&L for reinforced cement concrete (Nominal mix) type B1 (1:2:4) (using 20mm graded crushed stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed by Engineer-in-Charge 82 M&L for reinforced cement concrete (Nominal mix) type B1 (1:2:4) (using 20mm graded crushed stone aggregate) as Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed by Engineer-in-Charge 83 S&F Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by Engineer-in-Charge 84 S&F Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by Engineer-in-Charge 85 M&L for Formwork to flat soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) rough surface of concrete complete all as specified and as directed by Engineer-in-Charge 86 M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and as directed by Engineer-in-Charge 87 M&L for 20mm Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, over and including 15mm thick screed bed of cement mortar (1:4), colour of granite shall be approved by GE complete all as specified and as directed by Engineer-in-Charge 88 M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including 20mm thick screed bed of cement mortar (1:4) complete all as specified and directed by Engineer-in-Charge. 89 M&L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including 15mm thick rendering of cement mortar (1:4) complete all as specified and directed by Engineer-in-Charge. 90 M&L for vitreous china white table/counter top wash basin glossy ceramic art WBC vessel sink size 18x13 inches table top basin (including waste pipe and excluding pillar tap) complete all as specified and as directed by Engineer-in-Charge 91 M&L for 18-19mm thick Particle board, medium density, flat pressed, single layer type or three layer type with BWR type adhesive, fixed with screws to timber frame work complete all as specified and as directed by Engineer-in-Charge 92 S&F Continuous (piano) hinges, brass width of flap is 30 mm complete all as specified and as directed by Engineer-in-Charge 93 S&F 40mm dia, cupboard knobs fixed with nut, screw and washer of brass polished, bright finished complete all as specified and as directed by Engineer-in-Charge 94 Returning, filling in, includingspreading, levelling, watering and well ramming in layers not exc 25 cm. in any type of soil complete all as specified and as directed by Engineer-in-Charge. 95 Removing excavated soil / material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed by Engineer-in-Charge. 96 S&F looking mirror size 1200x900 including stainless steel studs 04 Nos complete all as specified and as directed by Engineer-in-Charge. 97 S&F in repairs 1000 litres capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 3 layer hoisted and fixed in position all as specified in SSR Part I complete all as specified and as directed by Engineer-in-Charge. 98 S&F in repairs Stainless steel sink with draining board, made out of 1.00mm thick steel sheet for kitchen or laboratory with plug, washers waste pipe, cast iron cantilever brackets, connecting union overall size 915mmx460mm with bowl size 410mm x 330mm x 160mm complete all as specified and as directed by Engineer-in-Charge. 99 S&F in repairs 15mm dia Bib taps, cast copper alloy chromium plated fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed by Engineer-in-Charge. 100 S&F in repairs 15mm dia Pillar taps mixer, cast copper alloy, fancy type, with capstan heads, chromium plated, screwed down high pressure, with or without lettered Hot or Cold with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and as directed by Engineer-in-Charge. 101 S&F in repairs 15mm dia Brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and as directed by Engineer-in-Charge. 102 S&F in repairs 15mm dia Stop valves, cast copper alloy fancy type chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed by Engineer-in-Charge. 103 S&F in repairs 20mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed by Engineer-in-Charge. 104 S&F in repairs 32mm bore Waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and as directed by Engineer-in-Charge. 105 S&F Liquid soap container of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats. (Minimum weight 105gms) complete all as specified and as directed by Engineer-in-Charge. 106 S&F PVC connections 15mm size with PTMT nuts of length 600mm complete all as specified and as directed by Engineer-in-Charge. 107 Supplied & fixed 25mm 2nd class hard wood boarding, in wall paneling with nails in any situation (except flooring and skirting) Planed one side and edges tongued and grooved or rebated complete all as specified and as directed by Engineer-in-Charge. 108 M&L for Providing precast cement concrete (1:2:4) type B1 (Using 20mm graded crushed stone aggregate) as in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain face and setting in cement mortar (1:4) complete with joints to match complete all as specified and as directed by Engineer-in-Charge. 109 M&L for plain cement concrete (1:3:6) type C2 (using 40mm graded crushed stone aggregate) in surface channels and drains complete all as specified and as directed by Engineer-in-Charge. 110 M&L for providing, cement concrete (1:3:6) type C1 (using 20mm graded crushed stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed by Engineer-in-Charge. 111 M&L for Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and as directed by Engineer-in-Charge. 112 S&F 110 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed by Engineer-in-Charge. 113 S&F 75 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed by Engineer-in-Charge. 114 S&F 110 mm dia PVC (SWR) bends any radius complete all as specified and as directed by Engineer-in-Charge. 115 S&F 75 mm dia PVC (SWR) bends any radius complete all as specified and as directed by Engineer-in-Charge. 116 M & L for point wiring for one light point/fan point controlled by one switch with 1.5 sqmm PVC FRLS insulated unsheathed copper conductor single core multi strand flexible cable and 1.5 sqmm PVC FRLS insulated unsheathed copper conductor single core cable (green colour) as earth lead in and including PVC casing and capping mediumgrade of suitable size run on wall/surface with all fittings (ISI Marked) controlled by one switch including CI/MS/ woodensunk box of required size & 3mm thick plastic laminated sheet, including cutting chases to wall making good the disturbed surfaces to match with theexisting specification complete all as specified and directed by Engineer-in-Charge. 117 Description All as per srl item No-116 here in above but for one 3 pin 5A socket outlet on the independent board controlled by one switch complete all as specified and directed by Engineer-in-Charge. 118 Description All as per srl item No-116here in above but for one 5A socket outlet on the same board controlled by one switch complete all as specified and directed by Engineer-in-Charge. 119 Description All as per srl item No-116above but for 3 pin socket outlet 15 Amps independent board with 2.5 Sqmm. 120 S&F Socket outlet 3 pin, 5A, flush type complete all as specified and directed by Engineer-in-Charge. 121 S&F switch piano flush type, 05/06 Amps single pole, one way 240 volts complete all as specified and directed by Engineer-in-Charge. 122 Supply & Fixing Switch socket combination 3 pin 16A, flush type 240 volts complete all as specified and directed by Engineer-in-Charge. 123 S&F Modular Switch one way6 A, 1 module complete all as specified and directed by Engineer-in-Charge. 124 S&F Modular Switch one way16 A, 1 module complete all as specified and directed by Engineer-in-Charge. 125 S&F Modular Socket, 6A - 2/3 pin combined 2 module complete all as specified and directed by Engineer-in-Charge. 126 S&F Modular Socket,6A16A - 2/3 pin combined 2 module complete all as specified and directed by Engineer-in-Charge. 127 S&FModular step type regulator, 120 W - 2 module complete all as specified and directed by Engineer-in-Charge. 128 S&F Modularwhite cover plate with frame, 2 module complete all as specified and directed by Engineer-in-Charge. 129 S&F Modularwhite cover plate with frame, 3 module complete all as specified and directed by Engineer-in-Charge. 130 S&F Modularwhite cover plate with frame, 4 module complete all as specified and directed by Engineer-in-Charge. 131 S&F Modularwhite cover plate with frame, 6 module complete all as specified and directed by Engineer-in-Charge. 132 S&FModularwhite cover plate with frame, 8 module complete all as specified and directed by Engineer-in-Charge. 133 Supply & fixing of ceiling rose, 3 phase/PVC/polycarbonate isolated body complete all as specified and directed by Engineer-in-Charge. 134 Supply & fixing lamp holder (Angular / Straight), insulated body, with back plate for batten fitting complete all as specified and directed by Engineer-in-Charge. 135 Supply and fixing LED lamp 10 W complete all as specified and directed by Engineer-in-Charge. 136 S&F decorative ultra slim linear LED 18/20 Watt 4 long lighting fixture with extruded aluminium heat sink, environment friendly, energy efficient ready to usepack includingLED tubecompletewith inbuilt electronic driver, PCB, connector block etc. including connecting up threecopper flexible cable from ceiling rose to fittings including connecting up and fixed on including two nos PVC square box of required size complete all as specified and directed by Engineer-in-Charge. 137 Supply and fix wall fan 400mm sweep high speed 230 volt AC, single phase, 50 Hz, with jerk free oscilation, smooth running, three blades, pull cords including fixing arrangements complete all as specified and directed by Engineer-in-Charge. 138 Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250m complete all as specified and directed by Engineer-in-Charge. 139 Supply and fixing round shape ceiling downlight 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engineer-in-Charge. 140 Supply and fixing round shape ceiling downlight 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engineer-in-Charge. 141 S&F square type recess mounted 10W LED white/warm colour pressure die- cast aluminium luminairein powder coated white finish in round/Square profile with optimized heat sink for efficient heat dissipation and separate replaceable electronic driver, including provision of fixing in ceiling with all items required for fixing complete all as specified and directed by Engineer-in-Charge. 142 S&F LED Bldg security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engineer-in-Charge. 143 Supply and Fixingsheet metal enclosure double door, (TPN)Triple pole and neutral, Vertical type AC, 415 volts, 4 way, with 200 Amps rated copper bus bar and IP - 43 protection with metal double door and flush to wall including all cutting on wall and making good including two coats of white/colour washing/distempering etc to match the existing disturbed surfaces complete all as specified and directed by Engineer-in-Charge. 144 Supply and Fixingsheet metal enclosure double door, (SPN) Single pole and neutral, AC, 240 volts, 4 way, with 200 Amps rated copper bus bar and IP - 43 protection with metal double door and flush to wall including all cutting on wall and making good including two coats of white/colour washing/distempering etc to match the existing disturbed surfaces complete all as specified and directed by Engineer-in-Charge. 145 Supply and Fixing in replacement, (Incomer in V TPN DB) MCCB63 Amp rupturing capacity 16kA, 4 pole 415 volts fixed type complete all as specified and directed by Engineer-in-Charge. 146 Supply and fixing sheet metal enclosure double door, single pole and neutral, AC, 240 volts, 8 way, with 200 Amps rated copper bus bar and IP - 43 protection with metal double door and flush to wall including all cutting on wall and making good including two coats of white/colour washing/distempering etc to match the existing disturbed surfaces complete all as specified and directed by Engineer-in-Charge. 147 Supply and fixing MCB, SP, AC, 240 volts B series capacity of 06 to 32 Amps, 10kA and making connections complete all as specified and directed by Engineer-in-Charge. 148 Supply & fixing MCB, SPN (single pole neutral), AC, 240 volts, B series capacity32 Amps10kA and making connections complete all as specified and directed by Engineer-in-Charge. 149 Supply andlaying or fixing or passing through pipe or binding with fencing/pole etc, 1100 volts grade heavy duty cable with PVCinsulated aluminium conductor servedwith an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 Sq mm nominal cross section 2 core solid conductor complete all as specified and directed by Engineer-in-Charge. 150 Supply and installed water heater vertical type, stationary storage type of 25 litre capacity having S/S inner vessel, five star rating , ISI Marked close/vented type (star marked) , 240 volts with heating element and auto cut thermostat, maximum out put of hot water is 60degree celsius, including fixing arrangement nut bolts, washer/fasteners and finishingwork etc complete as per existing surface, complete all as specified and directed by Engineer-in-Charge. 151 S&F PVC connection, ISI marked, 15mm dia 600mm long with brass nuts suitable for hot/ cold water supply complete all as specified and directed by Engineer-in-Charge. 152 Supply and fix Metal plug and socket with MCB 20 Amps SPN and steel enclosure complete all as specified and directed by Engineer-in-Charge. 153 Supply andlaying or fixing or passing through pipe or binding with fencing/pole etc, 1100 volts grade heavy duty cable with PVCinsulated aluminium conductor servedwith an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 16 Sq mm nominal cross section 2 core solid conductor complete all as specified and directed by Engineer-in-Charge. 154 S&L and Fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 2.5 sqmm nominal cross section, 2 core in service connections complete all as specified and directed by Engineer-in-Charge. 155 Supply & Layingand Fixing or passing through1100 volt grade copper conductor cable single core 1.5 sq mmcomplete all as specified and directed by Engineer-in-Charge.( Note : Two run of single core PVC insulated cable with Copper conductor unsheathed cable of size 1.5 Sqmm and one run of 1.5 Sqmm PVC insulated copper conductor single core, one run of PVC conduit shall be measured as single run) 156 M&L Earthing complete with GI steel earthplateelectrode 600x600x6mm burrieddirectlyin groundnotless than2.25mtr deepbelow normal ground level with top edgeof earth plate not less than 1.5mtr below normal ground level connected to the Galvanised iron wire 4mm dia by meansof bolts, nuts, check nuts andwashers of galvanised steel all as shown on electrical plateNo 3 of MES Sch 2009 Part-I connected to earthing test point and testing on completion with and including necessary excavation and earthwork, earth electrode, earthing lead from electrode to eqpt/sub stn , adequate quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 using 20mm graded black trap/granite/basalt stone aggregate, 40mm thick cover reinforced with 8mm dia bar 4 Nos both way with 12mm dia round bar handle, GI light grade watering pipe 20mm bore with funnel and wire mesh and 15mm dia GI light grade earth lead protection pipe up to equipment max length 7.5 mtr complete all as specified and directed by Engineer-in-Charge.Note:- On testing after completion if the desired resistance is not obtained the contractor shall redo the earthing without any extra cost to the department . 157 Supply and laying and testing cable XLPE insulated screened, PVC bedded, RM galvanized steel strip or wire armoured electric power cables (heavy duty) with stranded aluminium conductor, 11000 volts grade, of size 50 sqmm, 3.5 core complete all as specified and directed by Engineer-in-Charge.

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 09-06-2025 AMDT TO TENDER DOCUMENTS Other 20-06-2025
2 09-06-2025 EXTENSION OF CRITICAL DATES Date 20-06-2025
3 20-06-2025 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 27-06-2025

Key Value

Document Fees
INR 500 /-
EMD
INR 88860.0 /-
Tender Value
INR 44.43 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail