| 1 | Earth work in excavation in foundation, trenches etc. including dressing of sides and ramming of bottoms,includinggettingouttheexcavated material, refilling after laying pipe/ foundation and disposal of surplus excavated material at a lead upto 50m suitable site as per direction of Engineer for following depths, belownatural ground / Road top level. In all types soils/ saturated soil such as moorum, sand, sandy silt, clay, black cottonsoil, kankar,etc. |
| 2 | Random rubble dry stone Kharanja (soling) underfloor. |
| 3 | Providing and laying lean cement concrete 1:4:8 inSub-baseoverapreparedsub-gradewith coarse and fine aggregate conforming to IS: 383, thesizeofcoarseaggregatenotexceeding25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150kg/cum,optimummoisturecontenttobe determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days,mixedinconcretemixer,laidmanually, compactedwithsurfacevibrator,finishingand curingcompleteasperclause601,112of MoRT&H specification including all material, labour,machinery,lighting,guardingand maintenance of diversion. |
| 4 | Randomrubblemasonrywithhardstoneinfoundation and plinth |
| 5 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement -All work upto plinth level : |
| 6 | Reinforcement for R.C.C. work at all levelsincluding straightening,cutting, bending, placing in position and binding all complete. |
| 7 | Centringandshutteringwithplywoodorsteel sheet upto two stories ( each story of height upto 3.5metrefromfloorlevel)includingstrutting, propping etc. and removal of form for : |
| 8 | Brick work with FPS bricks of class designation75 in foundation and plinth in: |
| 9 | HalfbrickmasonrywithFPSbricksofclass designation75insuperstructureaboveplinthlevel upto two stories. |
| 10 | Supplyingandfixingstonelintels/bedplatesof approved quarry rough dressed in cementmortar 1:4 : |
| 11 | CementplasteringincludingT&P,scaffolding, materialandcompletelabour,includingcostof water,curing,rackingof joints etc. with12 mm cement plaster of mix : including Providing/mixing of synthetic fibers compulsorily complying with IS 16481:2022 of 06 mm/12 mm length to be mixed @ 0.25% by weight of Cement i.e. 125 gms per50kgCementupto900gmspercumof Concrete/ mortar |
| 12 | P&F1stqualityHeavyDutyVitrifiedDouble Chargedtilesonfloor,skirtingandstepsetc.in differentsizes(thicknessminimum10mm)with waterabsorptionless thanorequal0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1: 4 includinggroutingthejointswithwhitecement and matching pigment etc complete. |
| 13 | Providing and fixing aluminium work fordoors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sectionsandothersectionsofapprovedmake conforming to IS: 733 and IS : 1285, fixed with rawlplugsandscrewsorwithfixingclips,or with expansion hold fasteners including necessary filling up ofgaps atjunctions,attop, bottomandsideswithrequiredPVC/neoprene felt etc. Aluminium sections shall be smooth, rust free,straight,mitredandjointedmechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling,C.P. brass / stainless steel screws, all complete as perarchitecturaldrawingsandthedirectionsof Engineer-in-charge. (Glazing and panelling to be paid for separately) : |
| 14 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete asperthearchitecturaldrawings and the directions of engineer-incharge .(Cost ofaluminiumsnapbeadingshallbepaidinbasic item) : |
| 15 | GIwiregauge24gauge14meshofIS1568-1970 marked 85 gauge of dia 0.56 mm |
| 16 | Providingandfixingexternalgradeboardsolid coresingle leaf flushdoor shuttersISI2202-67 marked using Phenol formaldehyde resin in glue both sides including approved ISI marked Stainless Steel butt hinges fittings with necessary screws complete as per annexure \"A\" : |
| 17 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: |
| 18 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete |
| 19 | Finishing walls with Acrylic Smooth exterior paintof required shade : |
| 20 | Providing and fixing on wall face Unplasticised Rigid PVC Single socketed pipes rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. |
| 21 | Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. |
| 22 | Single tee without door 110x110x110 mm |
| 23 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm FR PVC insulated unsheathedflexiblecopperconductor1.1kV grade and 1.5 sq.mm FR PVC insulated unsheathedflexiblecopperearthconductor1.1 kV grade (IS:694) of approved make in surface / recessed ISI marked medium duty PVC conduit & it\"saccessories,roundtiles,18SWGM.S.box withearthterminal,screwlesscageconnectors for neutral looping in switch board & false ceiling point. 6 A switch, 3.0 mm thick phenolic laminated sheet, zinc plated / brass screws, cup washers, makingconnections, testing etc. as required. Short point (up to 3 mtr.) (Group-1) |
| 24 | Medium point (up to 6 mtr.) (Group-1) |
| 25 | Long point(up to 10 mtr..) (Group-1) |
| 26 | Wiring of 3/5 pin 6 amp. Light plug point as per PWDspecificationforelectricalWorkswithISI marked 1.5 sq. mm nominal size FR PVC insulatedunsheathedflexiblecopperconductor1.1kVgrade(IS:694)and1.5sq.mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessedISImarkedMMS(IS:9537P-III) vergin material PVC conduit & it\"s all accessories( J.B. , Bends etc.) , round tiles,18 SWG G.I. box with earth terminal of required size, 6 A switch, 3/5pin6Asocket,3.0mmthickISImarked phenolic laminated sheet (IS : 2036 - 1995), Al. alloy/cadmiumplatedironscrews20mmcup washers etc. all as per pre approved by Engineer in charge, making connections, testing etc. complete as required. For specification of copper Conductor,PhenolicLaminatedsheet\"s& Electrical/WiringaccessoriesreferChapterE- 04,E-05&E-07.Foradditionaltechnical parameters of products/ work , refer Annexure \"A\" attached with this BSR . |
| 27 | S&F following sizes (dia.) of ISI marked MMS ( IS:9537 P - III ) vergin material PVC conduit as perPWD specificationforelectricalWorksalong withitsaccessories(IS:3419)asrequiredin recess including cutting the wall, covering conduit andmakinggoodthesameasrequired.All relativeandlatestacceptancetestsreportsby any NABL accredited lab for the conduit shall be submittedbeforeexecution&Allasperpre approvedbyEngineerincharge.Foradditional technicalparametersofproducts/work,refer Annexure \"A\" attached with this BSR . |
| 28 | SupplyinganddrawingFRPVCinsulated& unsheathedflexiblecopperconductorasper PWDspecificationforelectricalWorkswithISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kVgrade.Wireshouldbemadefrom99.99% puritycopper,class5strandinginacc.toIEC 60228forlowerwattloss,oxygenfree(<10 ppm) for less chances of oxidization and higher silver content for gives better conductivity , insulationPVCtypeAorC ,flameretardantas per IS 10810-53, better amperage rating as per VDE 0298 part 4, , in existing surface or recessed PVC/ MS conduit/casing capping including all as per pre approved by Engineer in charge,making connections, etc. as required. OEM Must have its owninhouseNABLlabsetupforalltesting facilities for wires. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . 2 x 2.5 sq. mm. + 1x1.5sqmm |
| 29 | 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. |
| 30 | Providing&Fixingof240/415VACMCBwith positiveisolationofbreakingcapacitynotless than10KA(B/Ctrippingcharacteristicasper type ofload andsite requirement) 4KV impulse withstandvoltage, asper PWD specification for electrical Works with ISI marked IS 8828(1996) / conformingtoIEC60898-1 2002,IEC 60947-2, lowwattlosses,tripfreemechanisum,energy limitingofclass3asperIEC,minimumphase termination capacity of 35sq.mm. , conductorline loadreversibility,labelholdingfacility,IP20 contact protection and fitted with existing distributionboard/sheets,min.operation20,000 upto 32 A rating and 10,000 upto 63 A, 5000 for 80 A rating including making connections, testing etc. as required. . OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . 6 A to 32 A rating |
| 31 | Providing& Fixingof 240/415 V isolator as per PWDspecificationforelectricalWorkswithISI markedIS:13947-III/conformingtoIEC 60947-3, suitable for AC22A utilization catagory, 4KV impulse withstand voltage, true contact indication, Red colour dolly / lever shall have single mould covering over all poles for operation , two position dinrailmounting,minimumphasetermination capacity of 35sq.mm. , label holding facility , IP20contactprotectionandfittedwithexisting distribution board / sheet including making connections, testing etc. as required. OEM shall havesubmitNABL/CPRI/ERDAaccrediated lab test reports before execution & All as per pre approvedbyEngineerincharge.Foradditional technicalparametersofproducts/work,refer Annexure \"A\" attached with this BSR . |
| 32 | Providing & Fixing of ISI marked (IS:1258) 6 amp batten/anglelampholderasperPWD specification for electrical Works, made out from industrialgradePolycarbonateorfireresistant ABSmaterial,brassterminal&captivescrews including making connection testing etc. as required. All as per pre approved by Engineer in charge.Foradditionaltechnicalparametersof products/ work , refer Annexure \"A\" attached with this BSR . |
| 33 | P & F 18 swg M.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mm length extended on each side . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . |
| 34 | Providing & Fixing of IP20 SMD Mid Power LED battentypeintegratedlightfixturemadefrom polycarbonate/extrudedaluminiumpowder coatedhousing within builtdriver ,Power Consumption of 18W/20W ,system lumen efficacy≥ 120 lm/Watt output, internal surge protection of2.5 KV with Short & Open circuit protection ,THD< 10% ,p.f.≥0.95, CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K/6000°K/6500°K(AsperANSIBin),maximumpowerconsumptionshouldnotmore than the specified rating and Fixture shall be of BIS standardandtrademark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/Screenprintingonhousing.OEM must have its own in house NABL lab setup for all testingfacilitiesforLEDfixtures.(LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . foeadditionaltechnicalparametersofproduct/ work,referAnnexure\"A\"attachededwiththis BSR. |