| Sl. No. | Item Description |
| 1 | SCHEDULE \"A\" PART-IDemolition of cement or lime concrete in any despription and any position along with tarfelt treatment and cement mortar bedding from roof incl removal ofrubbish out side MD land complete all as specified and directed. |
| 2 | DismantlingAsbestos cement / GI (Corrugated, semi corrugated, etc) sheets including ridgesin roof covering complete all as specified and directed. |
| 3 | Dismantling wrought iron or mild steel work of any description complete all as specified and as directed. |
| 4 | Demolition of brick work built in cement mortar including all quions ,arcches , pillars etc complete all as specified and as directed. |
| 5 | Taking down cement plaster on brick or concrete surfaces, parapets including raking out joint, hacking for key, scrubbing down with water, at any description with necessary scaffolding of max height for G+2 Bldgsetc complete all as specified andas directed. |
| 6 | Dismantling floor, hearth or wall tiling including cement mortar bedding ( but not backing), and rubbish off the premises complete all as specified and directed. |
| 7 | M&L Plain cement concretetype B1 (1:2:4) using 20mm graded stone aggregate as in levelling course and other works as in roof, kerb, coping, padding etc complete all as specified and as directed. |
| 8 | M&L for water proofing treatment to non accessible roof and edges (vertical or tapered) / sumken portion etc. in following sequence:- (i) Properly cleaning and drying the surface(ii) Applying a coat of bitumen primer @ 1.2Kg/Sqm and primer shall be allowed to dry over night. (iii) Laying APP based modified water proofing membrane of weight not less than 3kg per sqm and thickness not less than 3 mm, with 100mm overlaps, sealed and bonded to the surface by \"torchon\" method (iv) Applying two coat of bituminous based aluminum painting@ 0.15 kg/Sqmeach coat on water proofing treatment with preparation of surfacescomplete all as specified and directed |
| 9 | M&L Application of Primer coat with mix of ShaliCrete/Liquid crete, a single componenet multifunctional acrylic polymer/ equivalent as above and cement in 1:2 ratio and applying @ 1Kg/Sqm of the mix and allow it to dry for 3 to 4 Hrs, etc complete all as specified and directed. |
| 10 | M&L PCC (1:2:4) for having lowest thickness at drain mouth of 40/50mm permixed with Shaliplast LW+/Liquidplast LW+ an integral water proofing admixture as specified and directed by Engr-in-charge. |
| 11 | M&L Preparation of cracks on wall / Roof/Chajja (other than hair cracks) filling by cutting it into \"V\" groove and fill it with polymer mortar made out of ShaliCrete/Liquidcrete as specified and directed |
| 12 | S & F steel work in tubular trussles,purlins,rafters,tubler column, where connected common rafter and running rails fixed with angle cleat or other connection plates including special shaped washers etc.complete using ERW or inductionbutt welded tubes confirming to Fe 410W grade E 250 quality B, etc complete all as specified anddirected. |
| 13 | M&L Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10cm girth complete all as specified and directed. |
| 14 | S & F in repairs MS framed work as in doors or gates of angle iron, door frame or other section with gusset plate, rails, braces and stair case etc complete, drilled for fixing of steel sheeting or other covering etc, to prepared for hanging or sliding with including either hooks and hinges also fastening grills, grating, hold fast of doors and windows chowkat etc, with ends of bars shouldered and or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walkways; railings; framework of water tanksand fixing and similar work confirming to fe 290 Gde E-165 complete all as specified and as directed. |
| 15 | M&L Preparation of newlysteel surfaces, of any description, over 10 cm width or girth, and applying two coats of synthetic enamel paint over a coat of red oxide complete complete all as specified and as directed. |
| 16 | S & F in repair galvanized mild steelwire clothes 0.56 nominal dia of wire and average width of aperture 1.18mm fixed with beading complete all as specified and directed. |
| 17 | S&F of 0.50mm thick (including coated thickness) pre-colourpre- profiled (Galvalume/zinkalume) curvagated/plain sheets of required colour and design having tensile strength of 550 Mpa asin roof sheeting/sunshade/ wall cladding, north light curves, fixed with zinc coated self drilling fastener including EPDM washer complete laid with one corrugation side laps and min 150mm end lap laid to slope all as per manufacturer / profile maker instruction complete all as specified and as directed. |
| 18 | S& F in repair Rotational moulded Polyethylene water storage tank 500 liters capacity (cylidrical vertical with closed top) hoisted and fixed in position all as specified in SSR part I incl brass float valve 20mm dia and dismantling water tank. complete all as specified and as directed. |
| 19 | S& F in repair Rotational moulded Polyethylene water storage tank 1000 liters capacity (cylidrical vertical with closed top) hoisted and fixed in position all as specified in SSR part I incl brass float valve 20mm dia and dismantling water tank. complete all as specified and as directed. |
| 20 | Disconnecting existing tanks nexc 500ltr capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing etc. measured separately). |
| 21 | Disconnecting existing tanks capacity of exc 500ltr and nexc 100ltr , setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing etc. measured separately). |
| 22 | Cleaning and removing all dirts and scales from service water tanksand from mouth of circulating pipes etc capacity of tank exceeding 250 ltr but not exceeding 500 ltrcomplete all as specified and directed. |
| 23 | All as per item no 22 above but exceeding 500 ltr but not exceeding 1000 ltr capacity complete all as specified and directed. |
| 24 | S&F in repair of 15mm bore valve high pressure of PTMT with epoxy coated aluminum rod & high density plastic ball screwed for iron pipes and fixed. ( Min Weight 15mm-142 gms) complete all as specified anddirected . |
| 25 | S&F in repair of 20mm bore valve high pressure of PTMT with epoxy coated aluminum rod & high density plastic ball screwed for iron pipes and fixed. ( Min Weight 20mm-210 gms) complete all as specified anddirected . |
| 26 | Taking up ordown 15 mm dia old serviceable / unserviceable steel tubing any grade and connections cleaning for re-fixing or removal to store complete all as specified anddirected . |
| 27 | All as per item no26 above but 20mm bore complete all as specified and as directed. |
| 28 | S&F steel tubing medium grade ,galvanized with all fitting such as bend ,elbow, socket,tees,and fixed complete to wall or in ceiling or in floors including cutting threading and making forged bends on pipes MS hooks etc ,for 15mm bore pipes complete all as specified and as directed. |
| 29 | All as per item no28 above but 20mm bore complete all as specified and as directed. |
| 30 | M&L brick work in CM ( 1:4 ) with using sub class `B ` modular brick straight or curved on plan exceeding 6.0mtr mean radius complete all as specified anddirected. |
| 31 | M&L brick work in CM ( 1:4 ) with using sub class `B ` modular half brick workstraight or curved on plan exceeding 6.0mtr mean radius complete all as specified anddirected. |
| 32 | M&L for rendering 10 mm thick in CM ( 1:6 ) on wall/ concrete surfaces finish even and smooth without using extra cementcomplete all as specifiedand directed. |
| 33 | M&L for 5mm thick plaster on ceiling in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and as directed . |
| 34 | Supply only Liquid water proofing compound complete all as spesified and directed. |
| 35 | M & L for preparation of new plasteredsurface of wall and applying two coats of oil emulsion distember over a coat of over a coat of cement primer over a coat ofwall care putty3 mm thick complete all as specified and directed. |
| 36 | M & L for preparing new surfaces of wall and applying two coats of white wash on ceilingand cornices complete all as specified and directed. |
| 37 | Material and Labour forapply two coats of Anti fungal weather coatwith acrylic smooth exterior emulsion paint applied 1.67kg/10sqm, of required shade over a coat of primer applied 2.20kg/10Sqm on new surfaces including 2-3mm thick wall care putty and including necessary sacfoldingof max height for G+2 bldg, etccomplete all as specified and directed. . Note:- (a) Each stage i.e. preparation of surfaces, application of primer, application of first coat, application of second coat will be got passed from Engr-in -Charge.(b)Written Warranty for four years or as per manufacturer\"s instructions, whichever is more is required to be furnishedby contractor for this item. |
| 38 | M & L for preparation of newplasteredsurfaces of walls and applying two coat of cement based paint over a coat of cement primer completeall as specified and directed |
| 39 | M&L for 75 mm thick PCC1:4:8 type D-2 using 40mm graded as in foundation, sub base of floor, etccomplete all as specified and directed |
| 40 | M&L for25mm thick PCC (1:2:4) type B-0using 12.50mm graded crushedstone aggregate as in sub base, levelling course, etc complete all as specifiedand as directed. |
| 41 | M&L for40mm thick PCCtype B1(1:2:4) using 20 mm graded stone crushed stone aggregateas in flooring complete all as specifiedand directed. |
| 42 | M&L for non –skidceramic colouredtiles 7-8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exc 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white or colouredcement to match over and including 15mm thick screed bed in CM 1: 6 complete all as specified and directed. |
| 43 | M&Lfor non –skidceramic colouredtiles 7-8mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exc 0.36 sqm in floors etc set and jointed in neat cement slurry and pointed in white or colouredcement to match over and including 15mm thick screed bed in CM 1: 6 complete all as specified and directed. |
| 44 | M&L for scratch free vitrified ceramic tiles7-8mm thick (square or rectangular) area of each tile not exceeding 0.36 sqm ,in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed or bedding layerin CM 1:6 complete all as specified and as directed. |
| 45 | All as per item no 44above but as in skirting/ dado etc with and including 10mm thik backing coat in cement mortar 1:4 an wall complete all as specified and as directed. |
| 46 | M&L for glazed ceramic coloured tiles of size 300x450x7 mm & 300x200x7 mm thick as required on site, on vertical surfaces such as wall, dado ,skirting etc set and jointed in neat cement slurry and pointed with coloured cement to match over 10 mm thickbacking coat on fair faces of brick work in CM (1:4) complete all as specified and as directed. |
| 47 | M&L for chequered cement concrete tiles with grey cementand pigment of size 30cmX30cmX25mm thick ,set and jointed and pointed in neat cement slurry in floor etc over and including 15mm thick screed bed in CM 1:6complete all as specified and directed. |
| 48 | M&L for cement concrete terrazzo tile in roof size of 25cmx25cmx20mm, machine pressed, set jointed and pointed in neat cement slurry with grey cement and no pigment , including well polished and girinding if required, etc complete all as specified and directed. |
| 49 | Dismantling of stone slab and tiles of any description or thickness in floors, aprons laid dry or bedded and pointed in any type of mortar complete all as specified and as directed. |
| 50 | M&L for 15-18 mm thickgreen marbleof approved quality ofany sizeset and jointed in greycementslurry laid over and including 15 mm thick screed bed in CM (1:4) includinggranitepolish to be done by mechanical grinder and moulding edges compete all as specified and as directed. |
| 51 | M&L for 18 mm thick Black granite slab of approved quality ofany sizebeddedand jointed in greycement slurry and pointed with white cement with admixture of pigment to match the shade of granite stonelaid over and including 15 mm thick screed bed in CM (1:4) including granite polish to be done by mechanical grinder and moulding edges complete allas specified anddirected. |
| 52 | M&L r for 60mm thick machine pressed precast concrete interlocking paver block (glossy finish) of M-35 Gde of approved shape, size and colourconferming to IS 15658-2006 and laid over and including 25mm thick sand cushion complete all as specified and as directed. |
| 53 | M&Lfor 80mm thick machine pressed precast concrete interlocking paver block (glossy finish) of M-40 Gde of approved shape, size and colourconferming to IS 15658-2006 and laid over and including 25mm thick sand cushion complete all as specified and as directed. |
| 54 | S & F for precast cement concrete type B-1 (1:2:4)(20mm graded stone aggregate ) as in kerb and edging to road and footh path, etc including chamfered,weathering, throating etc and setting in CM (1:4)complete all as specified and as directed. |
| 55 | S & F in repairs PVC (SWR) floor trap plain or multi with stainless steel grating incl joining to waste pipe with solvent cement joint dia of outlet 75mm bore complete all as specified and as directed. |
| 56 | S&F in repairs PVC connection15mm size with PTMT nuts of length 450 mm long complete all as specified and as directed. |
| 57 | S & F in repairs 110mm bore PVC (SWR) pipes singles socket in any length with rubber ring joints fixed to walls or floor or in trenches complete all as specified and as directed. |
| 58 | S & F in repairs 75mm bore PVC (SWR) pipes singles socket in any length with rubber ring joints fixed to walls or floor or in trenches complete all as specified and as directed. |
| 59 | S&F cast iron soil waste and vent pipes in any length with or without ears with lead joints in trenches or in floors using sand cast CI pipes 75mm bore pipes etc complete all as specified including dismantling old pipe complete all as specified and directed. |
| 60 | All as per item No 59above but for 100mm bore |
| 61 | S&F 110mm bore PVC (SWR) bends any radius complete all as specified and as directed. |
| 62 | S&F 75mm bore PVC (SWR) bends any radius complete all as specified and as directed. |
| 63 | S & F 110 mm bore PVC (SWR), junction single, (Single T) equal or unequal complete all as specified and directed. |
| 64 | S & F75 mm bore PVC (SWR), junction single, (Single T) equal or unequal complete all as specified and directed. |
| 65 | S& F in repair for 4 mm thick E Board claasic desinger ofsize 600x600mm as in false ceiling or similar work.complete all as specified and directed. |
| 66 | S&F in repair PVC sheet wall lining consisting of 5mm thick colour / printed PVC sheetinclusive of solvent cement and fixing at site including PVC frame as per specifications, complete all as specified and directed. |
| 67 | S & F in repairs false ceiling at all heights with GRG (Glass fibre Reinforced Gypsum) false ceiling tiles of size 595x595mm of approved texture, design and patterns having moisture content less than 2% humidity resistance of 99% NRCO.50 to 0.75 as per IS 8225:1987, Noncombustible as per BS 476 (part 4)-1970 and light reflectance of 85% (min) to be laid in true horizontal level suspended on inter locking metal T-grid of hot dipped galvanized iron section of 0.33mm thick ( galvanized @ 12a grams per sqm incl both sides ) comprising of main T runners of size 15x32mm of length 3000mm, cross T of size 15x32mm of length 1200mm and secondary intermediate cross T of size 15x32mm of length 600mm to form grid module of size 600x600mm, suspended from ceiling usung galvanized mild steel items (galvanizing @ 80 grams per Sqm) ie 50mm long 8mm outer diater M-6 dash fasteners 6mm dia fully threaded hanger rod upto 1000mm length and L shape level adjuster of size 85x25x2mm galvanised iron perimeter wall angle of size 24x24x0.40mm of length 3000mm to be fixedon periphery wall / partition with the helpcomplete all as specified and directed. |
| 68 | S&F in repairs POP 12mm thick Seamless calcium silicate ceiling made out of siliceous and calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25mm long self drilling and tapping screws having philips head with under head cutter at 200mm center to centre including finishing thr joints of face board with specially formullated jointing compound and 48 mm wide fibre tape to provide seamless finish with 12 mm thick for seamless false ceiling fixed with screw over and including Gl frame work comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre / intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete as per manufacturer instruction. |
| 69 | S&F 3.00 mm thick sheet glass ordinary quality and glazing with oil putty or wooden beading in square not exceeding 0.50 sqm in each panes including hacking out old broken glass( any tickness size ,quality or description ) from wooden frame or steel frame etc and complete all as specified and directed. |
| 70 | S&F 3.00 mm thick sheet glass figured glass pin head type and glazing with oil putty or wooden beading in square not exceeding 0.50 sqm in each panes including hacking out old broken glass( any tickness size ,quality or description ) from wooden frame or steel frame etc and complete all as specified and directed. |
| 71 | Resecuring or easing & adjusting, without taking down, shutters of any description n.exc 1.00 sqm each in same opening complete all as specified and directed. |
| 72 | Resecuring or easing & adjusting, without taking down, shutters of any description exc 1.00 sqm but n.exc 2 sqm each in same opening complete all as specified and directed. |
| 73 | M&L for cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregatre as in surface channels and drains complete all as specified and as directed. |
| 74 | Extra for forming fair finished surfaces of drain 30 cm inner girth in cement concrete using extra cement including forms mouldy mittered/ stopped ends complete all as specified and as directed.. |
| 75 | S&F in repair for 15mm bore bib taps chromium platedwith crutch or butterfly handle ,screwed down , screwed for iron pipes or brass ferrulecompleteall as specified and directed. |
| 76 | S&F in repairstop valves fancy type chromium plated with long shanks fixed with 15 mm dia bore pipes complete all as specified and as directed. |
| 77 | S&F in repair pillar tap (swan neck type) cast copper alloy with capstan head, screwed down ,high pressure with long screwed shanks and fly nuts fixed in 15 mm bore pipes complete all as specifiedand directed. |
| 78 | S&F in repair CP angle stop cock of 15mm bore screwed down for high pressure with crutch or butter fly handle ,screwed both end for iron pipes complete all as specifiedand directed.. |
| 79 | S&F in repair CP mixer for mixing hot & cold water screwed down for ironpipe 15mm borecomplete all as specifiedand as directed. |
| 80 | S&F in repair 125 mm size chromium plated showerrosewith siwel joint suitable for 15 mm bore GI pipes comlete all as directed.. |
| 81 | S&F in repair vitreous china wash down water closet pedestalpattern white excluding flushing cistern and flush pipes complete all as specified and as directed . |
| 82 | S&F in repair vitreous china squatting pan `Orissa \" pattern of size 580x440mm white with integral foot rest (excluding flushing cistern and flush pipes) including connection to trap and to flush pipe etc and lime concrete bedding including \"P\" or \"S\" trap complete all as specified and as directed. |
| 83 | M&Lin repairs PVCvalve less,syphonic action type flushing cistern,low level ,white with inlet ball valve,float and handle including bracketsand connection to pipe and fixing of chainand pull or lever if any complete all as specified and directed. |
| 84 | S&F in repair health faucet with flexible pipe of one mtr length including wall hook forEWC complete all as specified and as directed. . |
| 85 | S&F in repair vitreous china wash hand basin white flat back, size 550x400 mm including bracket but excluding taps ,waste pipes , chain and plug etc complete all as specified and directed. |
| 86 | S&F vitreous china urinal bowl urinal flat back, size of 465x355x265mm white (min)with grating and union for discharge pipe, urinal spreader with waste pipe and all fiting for urinal. |
| 87 | S&F stainless steel bottle trap for urinal and wash hand basin waste water outlet incl necessary fittings and connect to drain pipe, etc complete all as specified and directed. |
| 88 | Taking down cement plaster or decayed portision of concrete from ceiling, chajja, upward facia, downward facia in any position, any height (upto 3nd floor) and making good by, rendering 15mm thick with CM 1:4 or PCC 1:2:4 type B1 (using 20mm graded aggtregate) as in ceiling or concrete surfaces such as chajja, upward facia, downward facia and similar work finished even and fair including dubbing coat without use extra cement upto, any height ( upto 2nd floor) including necessary scafolding complete all as specified and as directed. |
| 89 | Demolition of reinforced cement concrete of any description and in any position not otherwise described comlplete all as specified and directed. |
| 90 | M&L RCC type B-1 1:2:4 using 20mm graded stone aggregateas in kitchen shelves , manhole cover, etccomplete all as specified and directed. |
| 91 | M&L form work to suspended slab as in kitchen shelves, cubboards,for fair finished surfaces inl formwork for fair finished surfaces complete all as specified and directed. |
| 92 | M&L TMTbar 10 mm dia and over, cut to length, bent to shape required ,including cranking ,bending spirally for hooping for columns,hooking end and binding with and including mild steel wire and annealednot less than .9 mm dia or securing with clips complete all as specified and directed. |
| 93 | M&L forRemoval of exisiting treatment on ceilingincluding preparation and applying two coat of white wash on ceiling complete all as specified and as directed. |
| 94 | M&L for Preparation of old decoratedplastered surfaces or un-plastered surfaces of wall and applying one coat of oil emulsiondistemper complete all as specified and as directed . |
| 95 | M&L forRemoval of existing treatment and preparation of old decoratedplastered surfaces or un-plastered surfaces of wall and applying twocoat ofoil emulsiondistemper complete all as specified and directed . |
| 96 | M&L forComplete removal of existing treatment and applying two coat of synthetic enamel paint on wooden surfaces of any description over 10 cm width or girth complete all as specified and as directed. |
| 97 | M&L forComplete removal of existing treatment and applying two coats of synthetic enamel paint onsteelsurfaces of any description over 10 cm width or girth complete all as specified and as directed. |
| 98 | M&L for complete removal of existing treatment (any number of layers) on walls scrapping with steel scrapper or any other means,including filling depression of scrapped surface ,priming plaster and other old surface with alkali resistant priming paint and applying two coat of cement base paint all as specified and directed. |
| 99 | Material and Labour for complete removal of old decoratedsurfaces of wall, pillasters,cornices etc by brooming down or steel wire brushing,scrapping down and washing with water. after completion of precoat treatment apply two coats of Anti fungal weather coat acrylic emulsion paint over a coat of primer including 2-3mm thick wall care putty and including including necessary sacfolding, complete all as specified and directed. . Note:- (a) Each stage i.e. preparation of surfaces, application of primer, application of first coat, application of second coat will be got passed from Engr-in -Charge.(b)Written Warranty for four years or as per manufacturer\"s instructions, whichever is more is required to be furnishedby contractor for this item. |
| 100 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion from cement concrete and making good disturbed ground complete all as specifed |
| 101 | Excavation for post holes in any type of soil (or in similar hole ) each n.exc 0.50 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around in layers not exc 25cm including dismantling PCC including disposal of surplus n.exc 50m all as specifed and directed |
| 102 | M&L forPCC 1:3:6 type C-2 (40mm graded aggts) in foundation filling and mass concrete all as specified and directed |
| 103 | M&L for posts and struts in fencing of angle, tee including cutting tops to shape as directed, drilling holes, notching for wire, Y angles wall for fencing, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 410-0 or FE 310-0 complete all as specified and directed etc complete all as specifed |
| 104 | Fixingchain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc including provision of binding wire complete. |
| 105 | Supply only Chain link fencing with or without line wires,any type andmesh size and any type of standards and dia of wire ( as directed by Engineer-in-charge) fixed with rails, staining bolts etc including provision of binding wire including dismantling existing unserviceable fencing all as specifed and directed.( rails, staining bolts will be measured in seperate Item) |
| 106 | S&FMild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long and 5 to 10mm dia of shank complete all as specified and directed |
| 107 | M&L for Preparation new steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint complete all as specified and as directed by Engr-in-charge |
| 108 | Dismantling of barbed wire fencing of any description and any positions complete all as specified and as directed. |
| 109 | Demolition of cement concrete (Reinforced) of any description and any position not other wise specifically provided reinforcement cut as required to facilitate demoltion. incl removal ofrubbish out side MD land |
| 110 | Demolition of cement concrete in ground floor and paving n.exc 15cm thickness(below & above GL) unreinforced complete.incl removal ofrubbish out side MD land |
| 111 | Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth, for foundation, laying of cables/pipes etc, or for shaft, well, cesspits, manhole, pier holes etc, not exceeding 10Sqm on plan and not exceeding 1.5m in depth and getting out in hard/dense soil, complete all as specified and directed. |
| 112 | M&L for plain cement concrete type D-2, 1:4:8 (using 40 mm graded crushed stone aggregate) as in foundations, filling and mass concrete, complete all as specified and directed. |
| 113 | M&L for Brick work with sub class \"B\" (old size) bricks, straight or curved on plan to any radius built in cement sand mortar 1:4, complete all as specified and directed. |
| 114 | Returning filling in, with approved excavated soil including spreading levelling watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed. |
| 115 | Removing excavated material (soil) to a distance not. exc. 50 mtr and depositing where directed at a level nexc 1.5 mtr above the starting point complete all as specified and directed. |
| 116 | M&L for rendering 10mm thick in cement mortar 1:4 using water proofing compound as per manufacturer instructions on fair faces of brick work or cement concrete surfaces including finishing the surface even and smooth without using extra cement, complete all as specified and directed. NOTE : WPC shall be measured and paid separately. |
| 117 | M&L for Rendering 15mm thick in two layers [base layer 10mm in CM 1:4 & finishing layer 5mm thick in cement mortar (1:4)] usingwater proofing compound in 2nd layer only on brick work or concrete surfaces of wall, surfaces finished even and smooth using extra cement upto any height incl neceeasry scaffolding( G+02 storey building) complete all as specified & directed. Note : WPC shallbe measured and paid separately |
| 118 | S&F Galvanised 2 strand, steel barbed wire 2.24 mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins etc as complete all as specified & directed. |
| 119 | Fixing onlygalvanised 2 strand, steel barbed wire of any description(obtained from dismantling)and straining and fixing to any type of standard rails straining bolts, including aluminium paint and securing or tying at crossing with and provn of galvanised MS wire complete all as specified and as directed. |
| 120 | Fixing,Restraining,resecuring incl making good staples etc of existing barbed wire fencing complete all as specified and directed. |
| 121 | M&L for preparation of newly plastered surface of wall applying two coat of cement base paint over a one coat of alkali resistant primer, complete all as specified and directed. |
| 122 | S&F in repair MS framed work as in grills, gratings or gates of angle or other section with necessary welding. bolting, riveting etc complete drilled for fixing of steel sheet or other covering , etc to be prepared for hanging or sliding with and including either hooks hinges so fastening and fixing complete as directed by Engr-in- charge |
| 123 | Dismantling of stone slab and tiles of any description or thickness in floors, aprons laid dry or bedded and pointed in any type of mortar complete all as specified and as directed. |
| 124 | M & L for machine cut kota stone slab flooring 20 to 25mm thick (size not less than 550mm x 550mm) laid & jointed with grey cement mixed with pigment to match the shade of slab including rubbing and mirror polishing finished laid over and including 20mm thick screed bed or bedding layer in CM 1:6 complete all as specified and as directed. |
| 125 | M & L for machine cut kota stone slab flooring 18 to 20mm thick as in riser of step, dado and skirting over and including 10mm thick 1:4 CM backing coat on vertical surface of wall with rubbing and mirror polishing finished complete all as specified and as directed. |
| 126 | M&L for 75 mm thickcement concrete 1:3:6 type C2 (using 40mm graded stone aggregate) as in plinth protection finished even and smooth without using extra cement laid shall be alternate panels and joints filled with bitumen mastic filling mix with 1 part bitumenand 3 part of sand complete all as specified and directed. |
| 127 | M & L for Preparation of old decorated plastered or unplastered surfaces of walls by brooming down or by steel wire brushes, scraping down smoke spot, moulds, moss and efflorescent salts, trading oil, greasy spots etc and applying one coat of cement base paint on walls (upto three storeyed bldgs complete all as spd and directed). |
| 128 | M&L forRemoval of exisiting treatment on ceilingincluding preparation and applying two coat of white wash on ceiling complete all as specified and as directed. |
| 129 | S & F venetian blinds with coloured flaps, guide rail, up and down rope/chain, etccomplete all as specified and directed by Engr-in-Charge. |
| 130 | M&L forPreparation of old decoratedplastered surfaces or un-plastered surfaces of wall and applying one coat of oil emulsiondistemper complete all as specified and as directed . |
| 131 | M&L forRemoval of existing treatment and preparation of old decoratedplastered surfaces or un-plastered surfaces of wall and applying twocoat ofoil emulsiondistemper complete all as specified and directed . |
| 132 | M&L forComplete removal of existing treatment and applying two coat of synthetic enamel paint on wooden surfaces of any description over 10 cm width or girth complete all as specified and as directed. |
| 133 | M&L forComplete removal of existing treatment and applying two coats of synthetic enamel paint onsteelsurfaces of any description over 10 cm width or girth complete all as specified and as directed. |
| 134 | M&L for complete removal of existing treatment (any number of layers) on walls scrapping with steel scrapper or any other means,including filling depression of scrapped surface ,priming plaster and other old surface with alkali resistant priming paint and applying two coat of cement base paint all as specified and directed. |
| 135 | Material and Labour for complete removal of old decoratedsurfaces of wall, pillasters,cornices etc by brooming down or steel wire brushing,scrapping down and washing with water. after completion of precoat treatment apply two coats of Anti fungal weather coat acrylic emulsion paint over a coat of primer including 2-3mm thick wall care putty and including including necessary sacfolding, complete all as specified and directed. Note:- (a) Each stage i.e. preparation of surfaces, application of primer, application of first coat, application of second coat will be got passed from Engr-in -Charge.(b)Written Warranty for four years or as per manufacturer\"s instructions, whichever is more is required to be furnishedby contractor for this item. |