| Sl. No. | Item Description |
| 1 | Construction of Modern workshop, Training room etc. at Govt. I.T.I. Sidhauli District-Sitapur (U.P.) |
| 2 | Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenchesor drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Earth work in Excavation in trenches for foundations pipes cable etc in ordinary soil (Loam clay or sand) including lift upto 1.5 m. lead upto 50m and dressing of sides and rammings of bottom and disposal of surplus exdavated earth as directed by the Engineer I/C within a lead of 30 m.(All kind of soil) |
| 3 | In all kind of soil upto 1.5m depth |
| 4 | In all kind of soil upto 1.5m to 3.0m. depth |
| 5 | In all kind of soil upto 3.0m to 4.5m. depth |
| 6 | Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. |
| 7 | Local Sand filling in plinth including supply of neccasary quantity of sandfrom the site of work 8km and including watering dessing etc. including cost of all materials labour and T&P etc . Required for proper completion of the work. |
| 8 | Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete(plinth area of the building at ground floor only shall be measured as per I.S.6313 (PartII 1981) Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows :(3) Treatment of top surface of plinth filling 5 liters/sqm |
| 9 | With Chlorpriphos EC 20% with 1% concentration |
| 10 | Providing and laying Cement Concret 1:4:8 (1cement :4coarse sand :8 stone aggregate 40mm including supply of all material ,labour and t&p etc.required for completion of work. |
| 11 | Providing and laying in position machine battched and machine mixed design mix M- 25 grade cement concrete for RCC work using cement content as per approved design mix. Including pumping of concrete to site of laying but including the cost of centreing, shuttering, finishing and Excluding reinforcement, including admixtures in recommended proportions as per IS 9103 to accelerate, retard setting of concrete, improve workability without impaaining strenght and durability as per direction of Engineer - In - Charge |
| 12 | All works upto plinth level |
| 13 | All works above plinth level upto floor V level |
| 14 | Centering and shuttering including strutting, propping etc. and removal of formfor |
| 15 | Foundations, footings, bases of columns, etc. for mass concrete |
| 16 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 17 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 18 | Suspended floors, roofs, landings, balconies and access platform |
| 19 | Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work(whennot includedin anover all rates )wroughttorequired shape as necessary including bending for proper completion of the work. FE 500 TMT BARS |
| 20 | Class-150 (non- Modular) brick work in foundation and Plinth including supply of all materials, labour and t&p etc. required for proper completion of the work. |
| 21 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 22 | Providing and laying damp proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 Coarse sand : 4 graded stone aggregate 12.5mm nominal size) |
| 23 | Providing and applying a coat of residual petroleum bitumen of grade of VG - 10 of approved quality using 1.7 kg per sqm. On DPCafter cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. |
| 24 | Brick work with common burnt clay (non moduler) brick of class -150 in super structure above plith lvl upto floor v lvl. In all shape and size in 1:4 (1: cement 4: coarse and mortar in one brick wall(230mm Thick) |
| 25 | Half Brick masonry with comon burn clay (non moduler) brick of class -150 in super structure above plith lvl upto floor v lvl. In all shape and size in 1:4 (1: cement, 4: coarse and mortar(115mm Thick) |
| 26 | Extra for providing and placing in position 5 Nos 10mm dia. M.S. bars at every third course of half brick masonry. |
| 27 | FLOORING |
| 28 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 29 | Size of Tile 600x600 mm |
| 30 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). |
| 31 | Size of Tile 600x600 mm |
| 32 | Providing and laying Homogeneous VINYL floor (armstrong) simpurity with diamond 10 coating . Thickness 2mm & 2 mtr. Wide thickness of wear layer would be 2mm & single layered. Operation complete as per direction of Engineer - In - Charge. |
| 33 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 34 | Providing and fixing rectified Glazed Ceramic floor tiles of size 300x300mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm. Including grouting the joints with white cement and matching pigments etc, complete. |
| 35 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. |
| 36 | Granite stone slab colour black, Cherry/Ruby red |
| 37 | Area of slab over 0.50 sqm |
| 38 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. |
| 39 | Granite work |
| 40 | 12 mm thik plaster with 1:6(cement :Coarse sand )2.25 F.M. over brick work minimum thickness not to be less than 1 cm .including supply of all material labour and T&P etc.required for proper completion of the work.Add for extra labour &materials for plaster over rough face of one brick wall .outer wall |
| 41 | 12 mm thik plaster with 1:6(cement :Coarse sand )2.25 F.M. over brick work minimum thickness not to be less than 1 cm .including supply of all material labour and T&P etc.required for proper completion of the work.Add for extra labour &materials for plaster over rough face of one brick wall .Inner wall |
| 42 | Engraving line in the plaster of the outer face wall vertically and horizontally to display the surface as s directed by the engineer -in-charges including labour and T&P etc. required for completion of work in the proportion recommended by the manufacture. |
| 43 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 44 | Finishing walls with Acrylic Smooth exterior paint(APEX)of required shade : New work (Two or more coat applied @ 1.25 ltr/10 sqm over and including priming coat of exterior primer applied @.75 LTR/10 sqm) |
| 45 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade : Two or more coats on new work.Applying one coat of water thinnable cement primer of approved brand and manufacture on wallsurface : |
| 46 | Painting with synthetic enamel paint or approved band and manufacture of required colour to give an even shade. |
| 47 | Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 48 | Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in heightdimension comprising of uPVC multi-chambered frame with in-built roller track and sash extrudedprofiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll formingprocess of required length (shape & size according to uPVC profile), appropriate dimension of uPVCextruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holesfor fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacentfinished wall shall be filled with weather proof silicon sealent over backer rod of required size and ofapproved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single /double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profiledimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 49 | Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels) made of (small series) frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area of window upto 1.75 sqm). |
| 50 | Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads ofappropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 51 | Casement door with 3D hinges made of (big series) frame 67 x 64 mm & sash 67 x 110 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension.(Area of door upto 2.00 sqm). |
| 52 | Mild steel or iron workofsmall sizes and sections suchas holding down bolts,holdfasttierods,gratings etc. ( when notincludedinan overall rates) wroughttorequiredfromincluding supply ofsteel anditswastage includingcostof bolts, nuts if required forandwelding, grinding and making holes as required completion of work. |
| 53 | 40X40X5 |
| 54 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. |
| 55 | 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 56 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architecttural drawings and the directins of engineer-in-charge (Cost of aluminium snap beadingg shall be paid in basic item) |
| 57 | With float glass panes of 5.5 mm thicness |
| 58 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, includingapplying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces |
| 59 | Providing and fixing of stainless steel 304 grade handle for door.32mmx 600 mm long sss.(Ozone make) |
| 60 | Providing and fixing ISI marked S.S Sliding door bolts with nuts and screws etc. complete |
| 61 | 300x16 mm |
| 62 | Providing and fixing ISI marked S.S.. Tower bolt black finish, (Barrel type) with necessary screws etc. complete |
| 63 | 300x10 mm |
| 64 | Providing and fixing S.S. handles with screws etc. complete: |
| 65 | 125 mm |
| 66 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required andmaking good the same matching to the existing floor finishing and cover plates with brass pivot andsingle piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-incharge.. |
| 67 | With stainless steel cover plate minimum 1.25 mm thickness |
| 68 | Supplying and fixing rolling shutters of approved make made of required size of M.S. laths interlocked together througgh their intire length and jointed together at the end by end locks mounted on specially designed pipe shall with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS:4454 part 1 and M.S. top cover of required thickness for rolling shutters. |
| 69 | Providing and fixing Top over for rolling shutter made of 18gauge M.S.sheet |
| 70 | Providing and fixing ball bearingg for rolling shutters |
| 71 | Extra for providingg mechanical device chain and crank operration for operating rollingg shutters. |
| 72 | Exceeding 10.00 sqm and upto 16.80 sqm in area (say average 14 sqm) |
| 73 | Providing and fixing tiled false ceiling of specified maerials of size 595x595mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanised steel sections (galvanised @120 grms/sqm, both side inclusive) consisting of maijn T runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet, spaced at 1200mm center to center and cross \"T\" |
| 74 | 12.5mm thick square edge PVC laminated Gypsum Tile of size 595x595mm made of Gypsum plastterboard, manufactured from natural gypsum as per IS 2095 part 1 and laminated with while 0.16mm thick fire etardand PVC film on the face side and 12 micron metalized polyester on the back side with all edges seated with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit. |
| 75 | Cement concrete flooring 1:2:4 ( 1 Cement : 2 Coarsesand : 4 gradede stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete (25 mm thick) |
| 76 | Appron Drain (150x150 ) sizewith M-150 Class brick workin 1:3 cement and coarse sandmortar F.M.2.5along appron including supply of all materials labour and t&Petc.required for proper completion of work. |
| 77 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approvedby engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-incharge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : |
| 78 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. |
| 79 | S/o Hand rail and balustarde modular systom passive ss-304 grade decorative railing system comprising of hand rail 50mm and 1.5 mm thick and 3 no .horizontal steel pipe of 19 mm dia and 1.5 mm thick of equal spacing with balustrade fo ss pipe of 38nn and 1.5mm thick @ 1200mm c/c of passivated ss304 rade and fix duly on the floor with spacially rivet expansion bolt and finish the surface food and covering with steel shoe ,with all visible stainless metal of 304 grade in satin finish hight of railing is 900 mm as per detailed speicification. |
| 80 | Providing precast cement concrete Jali 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 gradedstone aggregate 6mm nominal size ), reinforced with 1.6 mm dia mild steel wire, includingcentering and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3 (1cement: 3 fine sand) etc. complete, excluding plastering of the jambs, sills and soffits |
| 81 | 50 mm thick |
| 82 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: |
| 83 | W.C. pan with ISI marked white solid plastic seat and lid |
| 84 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: |
| 85 | White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap |
| 86 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and |
| 87 | Range of two urinal basins with 10litre white P.V.C. automatic flushing cistern. |
| 88 | Providing & fixing stone slab table rubbed, edges rounded and polished of size 75 X 50cm deep and 1.8 cm thick fixed in urinal patitions by cutting chase of appropriate width with chase cutter and embedding the stone in chase with epoxy grout or with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregste 6mm nominal size) as per Engineer-in-charge and finished smooth |
| 89 | Granite stone of approved shade |
| 90 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required: |
| 91 | Kitchen sink without drain board |
| 92 | 510x1040 mm bowl depth 250 mm |
| 93 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 94 | Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. |
| 95 | Flexible pipe |
| 96 | i) 32 mm dia |
| 97 | ii) 40 mm dia |
| 98 | Providing and fixing PTMT Bottle Trap for Wash basin and sink. |
| 99 | Bottle trap 31 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms. |
| 100 | Bottle trap 38 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms.(sink & urinal) |
| 101 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : |
| 102 | Rectangular shape 1500x450 mm |
| 103 | Providing and fixing toilet paper holder : |
| 104 | C.P. brass |
| 105 | Supply and fixing of UPVC S.W.R. pipe type -B confirming to IS- 13592 including jointing the pipes with rubber ring, lubricant and UPVC SWR cuplar confirming to IS - 14735. Also including excavation of trenches cutting of walls and holes and repairing the walls floors and refilling the trenches as before but excluding supply and cost of other fittings such as elbow, bead, tee and Y-tee including supply of all material labour and T&P .Required for proper completion of the work. |
| 106 | 75 mm O.D. |
| 107 | 110 mm O.D. |
| 108 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 109 | 75 mm |
| 110 | 160 mm |
| 111 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. |
| 112 | Shoe (Plain) |
| 113 | 75 mm Shoe |
| 114 | 110 mm Shoe |
| 115 | Supply and fixing of UPVC S.W.R. Cowel confirming to IS- 14735 |
| 116 | 110 mm size |
| 117 | Supply and fixin g of UPVC S.W.R. Nahni trap size 100/75mm, 100/90mm confirming to IS - 14735 self cleannig design fixed in PCC 1:2:4 and supply and fixing of 125mm dia heavy duty CP brass jali. |
| 118 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete. |
| 119 | a) 110mm |
| 120 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.Internal work - Exposed on wall |
| 121 | 20 mm nominal outer dia pipes |
| 122 | 32 mm nominal outer dia pipes |
| 123 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. |
| 124 | Internal work - Exposed on wall |
| 125 | 15 mm nominal outer dia Pipes |
| 126 | 20 mm nominal outer dia Pipes |
| 127 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. |
| 128 | 15 mm nominal outer dia pipes |
| 129 | 20 mm nominal outer dia pipes |
| 130 | 25 mm nominal outer dia pipes |
| 131 | 32 mm nominal outer dia pipes |
| 132 | Providing and fixing of gun metal gate valve with CI wheel of approved quality (screwed ends) |
| 133 | 25mm dia, nominal bore |
| 134 | 32 mm dia, nominal bore |
| 135 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : |
| 136 | 25 to 40 mm nominal bore |
| 137 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
| 138 | 45 cm length |
| 139 | 15 mm nominal bore |
| 140 | Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work (internal work -exposed on walls) |
| 141 | 20 mm nominal outer dia pipes |
| 142 | 25 mm nominal outer dia pipes |
| 143 | 32 mm nominal outer dia pipes |
| 144 | Painting GI pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality |
| 145 | 40 mm dia, nominal bore |
| 146 | 50 mm dia, nominal bore |
| 147 | Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work |
| 148 | 40 mm dia, nominal bore |
| 149 | 50 mm dia, nominal bore |
| 150 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : |
| 151 | 15 mm nominal bore |
| 152 | Providing and fixingG.I. union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (new work) |
| 153 | 15mm nominal bore |
| 154 | Providing and fixing C.P. brass bib cock of approved quality confirming to IS:8931 |
| 155 | 15mm nominal bore |
| 156 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. |
| 157 | 15mm nominal bore |
| 158 | Providing and fixing C.P.brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 a) 15 mm nominal bore. |
| 159 | 15 mm nominal bore |
| 160 | Supply and fixing of UPVC S.W.R. pipe type -B confirming to IS- 13592 including jointing the pipes with rubber ring, lubricant and UPVC SWR cuplar confirming to IS - 14735. Also including excavation of trenches cutting of walls and holes and repairing the walls floors and refilling the trenches as before but excluding supply and cost of other fittings such as elbow, bead, tee and Y-tee including supply of all material labour and T&P .Required for proper completion of the work. |
| 161 | 160 mm O.D. |
| 162 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design : |
| 163 | 160/150 mm diameter pipe |
| 164 | Supply and fixing of UPVC S.W. R. Gully trap confirming to IS - 14735 size 150x110 mm dia of self cleaning design including fixed brick Masonary chamber 250x250x250mm Size i/ c supply and fixing of CI cover with frame weight not less then 4.50Kg. & CI grating 150x150mm complete in all respects. |
| 165 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) Fisnihed with a floating coat of neat cement complete as per standard design : |
| 166 | (a) Inside size 900 x 800mm and 500mm deep including C.I. Cover frame. |
| 167 | (b) Inside size 1200 x 1200mm and 1.0meter deep including C.I. Cover frame. |
| 168 | (b) Size 1200 x 900mm |
| 169 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 170 | Providing and laying of cement concrete in base excluding the cost of centring and shuttering by 1:2:4 (1 cement : 2 coarse sand : 4 gradded stone aggregae 40mm nominal size) |
| 171 | Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement. |
| 172 | Suspended floors, roofs, landings, balconies and access platform. |
| 173 | P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. |
| 174 | 12mm cement plaster on rough side of mix 1:3 (1 cement : 3 coarse sand) |
| 175 | Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars. |
| 176 | Providing and fixing C.I. tee at the inlet and outlet of septic tank. |
| 177 | Providing & fixing 75mm dia vent pipes. |
| 178 | Providing & fixing of 75mm dia cast iron terminal guard. |
| 179 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. |
| 180 | M.D. -10- Circular shape 500mm internal diameter |
| 181 | M.D. -2.5- Circular shape 450mm internal diameter |
| 182 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design. |
| 183 | With F.P.S. bricks |
| 184 | Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m.including getting out the excavated soil & then returning the soil as required,in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. |
| 185 | Pipes, cables etc. exceeding 80 mm dia. But not exceeding 300 mm dia |
| 186 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand :10 graded stone aggregate 40 mm nominal size) up to haunches of S.W.pipes including bed concrete as per standard design |
| 187 | 150 mm diameter S.W. pipe |
| 188 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete. |
| 189 | 150 mm dia. R.C.C. pipe |
| 190 | Providing and fixing square-mouth S.W. gully trap class SP-1 completewith C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be notless than 4.50 kg and frame to be not less than 2.70 kg as per standard design : |
| 191 | 150x100 mm size P type |
| 192 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 193 | Constructing brick masonry manhole with 75 class designation F.P.S. bricks in cement mortar 1:4 (1 cement : 4 coarse sand) RCC top slab with 1:2:4 mix (1 cement : 2 coarse sand: 4graded stone aggregate 20mm nominal size); foundation concrete 1:4:8 mix |
| 194 | (1 cement :4coarse sand: 8 graded stone aggregate 40mm nominal size) inside plasstering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 |
| 195 | (1 cement :2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design. |
| 196 | a) Inside size 90x80 cm & 500cm deep including C.I. cover with frame (light duty) total wt. of cover & frame to be not less than 38 Kg (wt. of cover 23 Kg & wt. of frame 15 Kg. |
| 197 | Providing orange colour safety foot rest of minimum 6mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS: 1786 having minimum cross section as 23 mm x25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruded legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures\"s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) complete as per design. |
| 198 | EXTERNAL WATER SUPPLY SYSTEM -II |
| 199 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, havingthermal stability for hot & cold water supply including all CPVC plain &brass threaded fittings This includes jointing of pipes & fittings with onestep CPVC solvent cement, trenching, refilling & testing of joints completeas per direction of Engineer in Charge. |
| 200 | 32 mm dia nominal bore |
| 201 | Providing and fixing gate valve (with cap complete with bolts, nuts, rubber insertion etc. |
| 202 | 32mm |
| 203 | Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design |
| 204 | With common burnt clay M-150.(non modular) bricks of class designation. |
| 205 | Excavation in Foundation in ordinary soil (Loam clay, or sand) including lift upto 1.5 metre (5 fts.) and lead upto 30m (100 fts) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-in-charge upto a distance of 30 m. (100 fts) from the foundation trenches. (Rate is including Royality). |
| 206 | From 0.00 mt to 1.50 mt |
| 207 | 1.50mt to 3.0 mt |
| 208 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttring, finishing and reinforcement- All work up to plinth level |
| 209 | 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 210 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level: |
| 211 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 212 | 15 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall. |
| 213 | Providing & fixing 100mm dia Drain pipes. |
| 214 | Providing & fixing of 75mm dia cast iron terminal guard. |
| 215 | Supplying and stacking at site. Over burnt (Jhama) brick aggregate 120 mm to 40 mm |
| 216 | FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL) |
| 217 | Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Jockey Pump)(B) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS: 1520.(C) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-\"F\" insulation, conforming to IS: 325.(D) M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.(E) Suitable cement concrete foundation duly plastered and with antivibration pads. |
| 218 | 300 lpm at 56 m Head |
| 219 | (A) Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)(B) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS: 1520(C) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horizontal foot mounted type with Class-\"F\" insulation, conforming to IS-325.(D) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(E) Suitable cement concrete foundation duly plastered and with anti vibration pads. |
| 220 | 450 lpm at 35 m Head |
| 221 | Control Panel |
| 222 | Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter-connection with suitable size copper conductor cable/solid copper strip, having switchgears andaccessories, mountings and internal wiring, earth terminals,numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required : |
| 223 | INCOMING250A, 50kA 4 Pole MCCB, Ics=100% Icu ratingDigital Voltmeter 0-500V with selector switchDigital Ammeter (0-250 A) with selector swtich & CTs etc.LED type RYB phase indicating lamps, ON, OFF, trip indicating lampsSet of Copper Bus Bar 300AOUTGOING(Note: All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps)MAIN FIRE PUMP125 A, 50KA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 60 HP pump with overload protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.JOCKEY PUMP63 A, 50KA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.DIESEL ENGINE CONTROLControl for diesel engine comprising -Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indicationBattery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0-20 A DC AmmeterAll standard relays and accessories for automatic operation of diesel engine |
| 224 | Providing, laying, testing & commissioning of \"C\" class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required: |
| 225 | 100 mm dia |
| 226 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required |
| 227 | 100 mm dia |
| 228 | Providing, installation, testing and commissioning of non-returnvalve of following sizes confirming to IS: 5312 complete with rubber gasket, Gl bolts, nuts, washers etc.as required : |
| 229 | 100 mm dia |
| 230 | Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. |
| 231 | 100 mm dia |
| 232 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63mm dia male and female couplings duly bound with GI wire, rivetsete. conforming to IS 636 (type-A) as required |
| 233 | Stainless Steel (Grade 304) |
| 234 | Supplying and fixing first-aid Hose Reel with MS construction spraypainted in post office red, conforming to IS 884 complete with thefollowing as required. 20 mm nominal internal dia water hose thermoplastic. (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket |
| 235 | 30m |
| 236 | Supplying and fixing of fir brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required: |
| 237 | 4 way - 150 mm dia M.S. Pipe |
| 238 | Providing, fixing, testing & commissioning of 15mm dia quartzoidbulb type sprinklers of rating 68 degree centigrade with requiredaccessories. |
| 239 | Providing & fixing of pressure switch in M.S. pipe line includingconnection ete. as required. |
| 240 | Providing & fixing flow switch in following sizes M.S. pipe including ‘connection etc as required. |
| 241 | 100 mm dia |
| 242 | 150 mm dia |
| 243 | CO2 type fire existinguisher capacity : 4.5 k.g. |
| 244 | Water type fire extinguisher capacity 9 ltr. |
| 245 | Point Wiring |
| 246 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 247 | Group C |
| 248 | Wiring for group controlled(looped) light point/fan point/exhaust fan point/call bell point(without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 249 | Group C |
| 250 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. |
| 251 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 252 | Submains |
| 253 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 254 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 255 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 256 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 257 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 258 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 259 | 4 X 16 sq. mm + 2 X 6 sq. mm |
| 260 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 261 | 5/6 A switch |
| 262 | 3 pin 5/6 A socket outlet |
| 263 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 264 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 265 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 266 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 267 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
| 268 | Upto 450 mm sweep |
| 269 | Installation ,Testing and commissioning of ceiling fan, including wiring thedown rods of standard length (up to 30 cm) with 1.5 sq. mm FRLSH PVC insulated , copper conductor , single core cable including providing and fixing phenolic laminated sheet cover on the fan box etc. as required |
| 270 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \"C\" curve including connections, painting etc. as required. (for A.C. Point/MCB Point) |
| 271 | Supplying and fixing following way, horizontal type three pole and neutral (TPN), sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 272 | 4 way (4 + 12), Double door |
| 273 | 6 way (4 + 18), Double door |
| 274 | 8 way (4 + 24), Double door |
| 275 | 12 way (4 + 36), Double door |
| 276 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 277 | 8 way (4 + 24), Double door(VERTICAL) |
| 278 | 12 way (4 + 36), Double door(VERTICAL) |
| 279 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 280 | Single pole |
| 281 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 282 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
| 283 | 125 A,30KA,FPMCCB |
| 284 | Supply and fixing of 40 Amp. 4 pole MCB (10 KA) C Curve. CAT A |
| 285 | Supply and fixing of 63 Amp. 4 pole MCB (10 KA) C Curve. CAT A |
| 286 | ELCB/RCCB Switches |
| 287 | Supplying and fixing following rating, four pole, (three phase and neutral) SPN, 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 288 | 40 A |
| 289 | Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet,with 4 pole and earth, metal enclosed plug top alongwith 30 A \"C\"curve, TPMCB, in sheet steel enclosure, on surface or in recess,with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 290 | Supplying and fixing 63 A, 415 V, TPN Industrial type socket outlet,with 4 pole and earth, metal enclosed plug top alongwith 63 A \"C\"curve, TPMCB, in sheet steel enclosure, on surface or in recess,with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 291 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 292 | Earthing Work |
| 293 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 294 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 295 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 296 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
| 297 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 298 | 225 mm width X 50 mm depth X 1.6 mm thickness |
| 299 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required. |
| 300 | 100 mm dia |
| 301 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 302 | L.T. Switch Panel Board |
| 303 | Supply& Erracetionof factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreise Electrical control panel with TPN MCCB\"s (Four Pole 36 KA with thermal magnatic release) Switches Complete and instrument chamber etc.complete in all respects. |
| 304 | The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters (KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above insulated with heat shrink sleeving and mounted on non gyroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. |
| 305 | The MCCB\"s shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm.Cubicletype switchboard shall be of cat A & B Only. CAT. B Cubicle Type |
| 306 | Main LT Panel : |
| 307 | Incoming - |
| 308 | 1250 AMP ACB EDO TYPE 2NO 56 KA |
| 309 | 1250 AMP ACB EDO TYPE 1NO 56 KA (BUS COUPLER) |
| 310 | BUS BAR 2500 AMP 4 P |
| 311 | Outgoing - |
| 312 | 630 Amp MCCB MDO 25 KA 400 KVAR ( CAPASTER BANK 2NO. ) |
| 313 | 63 Amp 4P MCB - 4 No. ( LIFT,PUMP,EXTERNAL LIGHT,BASEMENT DP ) |
| 314 | 200 Amp 4P MCCB - 35KA-6 No. ( VTPN DP) |
| 315 | Spare 63,Amp MCB,200 AMP MCCB without MCB - 2 No. |
| 316 | (Complete as per requirment directed by Project Manager.) |
| 317 | Lighting Fixtures (Lights/Fans) : |
| 318 | Supply and fixing of 12 Watt to 15 Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing body with extended heat sink and diffuser of Special Polycarbonate meterial and driver set complete in all respect.(CAT AAA) |
| 319 | Supply and fixing of 12 Watt to 15 Watt indoor surface mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing body with extended heat sink and diffuser of Special Polycarbonate meterial and driver set complete in all respect.(CAT AAA) |
| 320 | Supply and fixing of LED Tube Light with Metal heavy duty Box type batten Light fitting 2X22 watt suitable for upto 2X22 watt LED Polycarbonate tube light complete Including tube suitable for both surface & suspended complete in all respect.CAT. - AAA |
| 321 | Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following size |
| 322 | size 300 sq mm x 3.5 core |
| 323 | size 95 sq mm x 3.5 core |
| 324 | size 120 sq mm x 3.5 core |
| 325 | Supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed ,underground cable including rubber ring etc. complete in all respect. Thearmouring of the cable shall be properly connected with the earthas per direction of engineer-incharge. for cable |
| 326 | size 300 sq mm x 3.5 core |
| 327 | size 185 sq mm x 3.5 core |
| 328 | size 95 sq mm x 3.5 core |
| 329 | size 120 sq mm x 3.5 core |
| 330 | Supply and fixing ofplain or pin type copper tin plated cable socket (lug) to cable leadsfor pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cable |
| 331 | size 300 sq mm x 3.5 core |
| 332 | size 185 sq mm x 3.5 core |
| 333 | size 95 sq mm x 3.5 core |
| 334 | size 120 sq mm x 3.5 core |
| 335 | Supply and Laying of 1800*900*12mm thick chequerd rubber matting of tested quality. complete in all respect. as per I.E. Rules. |
| 336 | Supply & fixing of 225/300mm sweep ventilating (Light Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Copper motor for high air suction performance /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 45 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Motor type : Normal Speed. Complete in all respect. |
| 337 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/recessed steel/ PVC Conduit as required. |
| 338 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 339 | Supplying and fixing following size/modules, GI box along with modular base and cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mm x 75mm) |
| 340 | RAIN WATER HARVESTING WITH RECHARGE PITS |
| 341 | Reinforced cement concrete work in beams, suspended floor, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands,plain window sills, staircases and spiral stair cases above plinth level up to the floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1cement: 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregrate 20mm nominal size derived from natural sources). |
| 342 | R.C.C. work in Slab |
| 343 | 15 mm cement plaster on rough side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand) |
| 344 | Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design: |
| 345 | With 20x20mm square bar |
| 346 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. |
| 347 | Drilling of 300mm dia bore hole manually. |
| 348 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. |
| 349 | 150 mm nominal size dia |
| 350 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, inrequired thickness, for all leads & lifts, all complete as per directionof Engineer-in-charge. |
| 351 | Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. |
| 352 | DESILTING CHAMBER |
| 353 | Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. Theready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering processand finally finished by floating, brooming with wire brush etc. complete as per specifications anddirections of Engineer-in-charge. (The panel shuttering work shall be paid for separately). |
| 354 | Providing and filling in position rubberized bitumen hot sealing compound for sealing of expansion joints in roads/ pavements all complete as per directionof the Engineer-In-Charge. |
| 355 | 12 MM thick plaster (1:3) with coarse sand |
| 356 | Supply & installation of split direct expansion Air conditioners suitable for operation on A/C Supply single phase 50 HZ 230 Volts with hermetically sealed compressor with air cooled condenser ,motor capacitor and startrun capacitor .relay and over load protector internal unit ,with one indoor and one outdoor unit.The condenser unit will be placed outside the room on the terrace to avoid noise including standard lenght of suitable size copper tubing covered with insulation tube .(hIGH WALL CHORDED /CORDLESS ) SUITABLE CAPACITY 3 CORE SHEATHED /PVC COPPER CABLE AND A BATTERY OPERATED WIRELESS REMOTE.VOLTAS /HITACHI /SAMSUNG ETC. |
| 357 | Bee star rated :5 star ,EER3.4 1.5 TR |
| 358 | Supply & installation of split direct expansion Air conditioners suitable for operation on A/C Supply single phase 50 HZ 230 Volts with hermetically sealed compressor with air cooled condenser ,motor capacitor and startrun capacitor .relay and over load protector internal unit ,with one indoor and one outdoor unit.The condenser unit will be placed outside the room on the terrace to avoid noise including standard lenght of suitable size copper tubing covered with insulation tube .(hIGH WALL CHORDED /CORDLESS ) SUITABLE CAPACITY 3 CORE SHEATHED /PVC COPPER CABLE AND A BATTERY OPERATED WIRELESS REMOTE.VOLTAS /HITACHI /SAMSUNG ETC. |
| 359 | Bee star rated :5 star ,EER3.4 2 TR |
| 360 | Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) : 300 mm dia piles |
| 361 | Excavation in foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. |
| 362 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) |
| 363 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 364 | P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. |
| 365 | 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 fine sand. |
| 366 | Finishing wall with water proof cement paint of approved make and quality on new wood with two coat to give an even shade including supply of all materials, labour, tools and plant etc. required for proper completion of the work. (Two coat) |
| 367 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 368 | (a) Foundations, footings, bases of columns, etc. for mass concrete |
| 369 | GST Extra as applicable |