Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Construction of Morden workshop, Training room etc. at Govt. I.T.I. Bilgarm District-Hardoi (U.P.) |
| 2 | CIVIL WORK WORKSHOP (OPTION-B) |
| 3 | Excavation in foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. |
| 4 | Filling of Carted earth in plinth in 20cm layer including leveling, dressing and watering and also including of supply of earth including carted loading & unloading as per direction of Engineer incharge.. |
| 5 | Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. |
| 6 | Construction of apron drain along apron (150X150)MM |
| 7 | Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proper completion of work. |
| 8 | Providing and injecting chemical emulsion for pre constructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete. |
| 9 | (plinth area of the building at ground floor only shall be measured as per I.S.6313 (PartII 1981) Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1) Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm |
| 10 | (4) Treatment junction of wall and the floor 7.5 liters /sqm (5) Treatment of soil along external perimeter of building 7.5 liters/sqm (6) Treatment of soil under apron along external perimter 5 liters/sqm. (As per manufacturer\"s standard dilution) |
| 11 | Providing and laying in position specified grade of reinforced cementconcrete, excluding the cost of centering, shuttering, finishing andreinforcement 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from naturalsources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 12 | Upto plinth level |
| 13 | (i) R.C.C. work in Footing |
| 14 | (iii) R.C.C. work in Columns |
| 15 | (ii) R.C.C. work in Beam |
| 16 | Above plinth to floor-V lvl |
| 17 | Providing and laying in position specified grade of reinforced cementconcrete, excluding the cost of centering, shuttering, finishing andreinforcement 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from naturalsources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 18 | (iii) R.C.C. work in Columns |
| 19 | (i) R.C.C. work in Lintel |
| 20 | (ii) R.C.C. work in Beam |
| 21 | (iv) R.C.C. work in Slab |
| 22 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : |
| 23 | Foundations, footings, bases of columns, etc. for mass concrete. |
| 24 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. with water proof ply 12 mm thick |
| 25 | Columns,Pillars, Piers, Abutments, Posts and Struts. |
| 26 | Edges of slabs and breaks in floors and walls Under 20 cm wide. |
| 27 | M-150 brick work in 1:6 (one cement and six coarse sand sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. |
| 28 | Providing and laying damp-proof course 25 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size). |
| 29 | Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. |
| 30 | M-150 brick work in 1:6in super-structure above plinth level up to floor two level ( up to two storeys ) includingnecessarycutting and moulding of brick work asrequiredand also including honeycombed brick work in thickness of wall more than 12cms. (1:6 cement : coarse sand) |
| 31 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation Class M-150in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand) |
| 32 | P/F Fe-500 Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. |
| 33 | 15mm thick plaster with cement mortar in proportion of 1:4 cement & coarse sand of 2.25 F.M. |
| 34 | 15 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 coarse sand |
| 35 | 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 coarsesand. |
| 36 | Making grooves 10 to 12 X 12mm and upto 25 X 15 mm deep in plaster of the walls or in ceiling vertically or horizontally as required. |
| 37 | Homogeneous VINYL floor (armstrong) simpurity with diamond 10 coating . Thickness 2mm & 2 mtr. Wide thickness of wear layer would be 2mm & single layered. Operation complete as per direction of Engineer - In - Charge. |
| 38 | Supply and fixing 6 mm China white glazedtiles in flooring or in skirting or dado laid with 1:3 cement and approved coarse sand mortar finished with white cement slurry jointing and polishing complete including supply of all materials, labour and tool sand plants etc. required for proper completion of the work. (Size of tiles upto 300x300mm). |
| 39 | Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (40 mm thick floor). |
| 40 | Supply and fixing of anodised /aluminium windows having 2 mm thick aluminium section excluding coating & an average coating of 20 micron fully glazed made of aluminium door tube size 83.5x 44.65 mm as vertical member & 1114.00 x 44.45 mm size tube in bottom and horizontal members door chaukhat should be of aluminium tublar vertical with two openable shutters. The rate will include cost of material fixtures, 5mm glass handles, locks, screw necessary beeding & excluding cost of floor spring if required for proper completion of work as per direction of Engineer I/C. |
| 41 | providing and fixing in position MOTORIZED steel shutters with vertical channels 20x10x2mm (3/4\"x3/8\"x1/12\") and braced with flat form diagonals 20x5mm (3/4\"x3/16\") size with top and bottom rails or T-iron 40x40x6mm (1½\"x1½\"x1¼\") with 38 mm dia steel pullys with bolts, nuts locking arrangement, stoppers handles complete including applying a priming coat of approved lead paint. |
| 42 | Providing and fixing factory made UPVC white colour sliding glazed window upto 1.50m in height dimension comprising of UPVC multi chambered frame with inhuilt roller track and sash extruded profiles duly reinforced with 1.60 x 0.,2mm thick galvanised mild steel section made from roll formingg process of required length (shape & size according to UPVC profile) Three track threepanels sliding window made of (big series) frame 67x504mm & sash 46*65mm both having wall thickness of 2.3mm +/- 0.2mm and singloe glazing bead of appropriatedimension (Area of window upto 2.5sqm) |
| 43 | Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing.MS Grill |
| 44 | Finishing walls with Acrylic smooth exterior paint of required shade: - New work (Two or more coat applied @ 1.67 Ltr./10 Sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/10 Sqm. |
| 45 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade . Two or more coats on new work (For Internal ceiling surface) |
| 46 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 47 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height |
| 48 | including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above |
| 49 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg /sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/ sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 50 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes |
| 51 | Providing and fixing aluminium sliding door bolts, ISI marked anodised(anodic coating not less than grade AC 10 as per IS : 1868),transparent or dyed to required colour or shade, with nuts and screwsetc. complete: 300x16 mm |
| 52 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodiccoating not less than grade AC 10 as per IS : 1868 ) transparent or dyedto required colour or shade, with necessary screws etc. omplete: |
| 53 | 300 x 10mm |
| 54 | 200 x 10mm |
| 55 | Providing and fixing aluminium handles, ISI marked, anodised (anodiccoating not less than grade AC 10 as per IS : 1868) transparent or dyedto required colour or shade, with necessary screws etc. complete : 125 mm |
| 56 | Providing and fixing 150 mm bright finished floor stainless steel door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete. |
| 57 | Providing and fixing fly proof galvanised M.S. wire gauge, to windows and clerestory windows using galvanised M.S. wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.63 mm all complete. With second class teak wood beading 62 X 19mm. |
| 58 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 59 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand).Ordinary cement without any pigment |
| 60 | Providing and fixing tiled false ceiling of specified maerials of size 595x595mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanised steel sections (galvanised @120 grms/sqm, both side inclusive) consisting of maijn T runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet, spaced at 1200mm center to center and cross \"T\" |
| 61 | 12.5mm thick square edge PVC laminated Gypsum Tile of size 595x595mm made of Gypsum plastterboard, manufactured from natural gypsum as per IS 2095 part 1 and laminated with while 0.16mm thick fire etardand PVC film on the face side and 12 micron metalized polyester on the back side with all edges seated with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit. |
| 62 | Providing & fixingGE plastic 600mm dia Turbo vents of approved make and laying in position as per drawing or as per directed by Engineer in charge |
| 63 | SUPPLY AND FIXING OF MULTI COLOURED GALVANISED SHEET WITH SCREWS ON CLADDING. |
| 64 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after . |
| 65 | The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineerin- charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding. |
| 66 | This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done. |
| 67 | SANITRY AND WATER SUPPLY WORK |
| 68 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: |
| 69 | White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. |
| 70 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: W.C. pan with ISI marked white solid plastic seat and lid |
| 71 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: |
| 72 | White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap |
| 73 | Range of three urinal basins with 10litre white P.V.C. automatic flushing cistern |
| 74 | Providing & fixing stone slab table rubbed, edges rounded and polished of size 75 X 50cm deep and 1.8 cm thick fixed in urinal patitions by cutting chase of appropriate width with chase cutter and embedding the stone in chase with epoxy grout or with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregste 6mm nominal size) as per Engineer-in-charge and finished smoothGranite stone of approved shade |
| 75 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 76 | Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. i) 32 mm dia |
| 77 | Providing and fixing PTMT Bottle Trap for Wash basin and sink. |
| 78 | Bottle trap 31 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms. |
| 79 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Circular shape 450 mm dia |
| 80 | Providing and fixing toilet paper holder : C.P. brass |
| 81 | Supply and fixing of UPVC S.W.R. pipe type -B confirming to IS- 13592 including jointing the pipes with rubber ring, lubricant and UPVC SWR cuplar confirming to IS - 14735. Also including excavation of trenches cutting of walls and holes and repairing the walls floors and refilling the trenches as before but excluding supply and cost of other fittings such as elbow, bead, tee and Y-tee including supply of all material labour and T&P .Required for proper completion of the work. |
| 82 | 75 mm O.D. |
| 83 | 110 mm O.D. |
| 84 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm |
| 85 | Supply and fixing of UPVC S.W.R. door bend confirming to IS- 14735 |
| 86 | 90 mm size |
| 87 | 110 mm size |
| 88 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. |
| 89 | Bend 87.5° |
| 90 | 75 mm Shoe |
| 91 | 110 mm Shoe |
| 92 | Supply and fixing of UPVC S.W.R. Plain Tee confirming to IS- 14735 |
| 93 | 75X75X75 mm size |
| 94 | 110x110x110 mm size |
| 95 | Supply and fixing of UPVC S.W.R. Plain bend confirming to IS- 14735 |
| 96 | 75 mm size |
| 97 | 110 mm size |
| 98 | Supply and fixing of UPVC S.W.R. Door Y confirming to IS- 14735 |
| 99 | 75 mm size |
| 100 | 110 mm size |
| 101 | Supply and fixing of UPVC S.W.R. Cowel confirming to IS- 14735 |
| 102 | 75 mm size |
| 103 | 110 mm size |
| 104 | Supply and fixin g of UPVC S.W.R. Nahni trap size 100/75mm, 100/90mm confirming to IS - 14735 self cleannig design fixed in PCC 1:2:4 and supply and fixing of 125mm dia heavy duty CP brass jali. |
| 105 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour weighing not less than 105 gms. |
| 106 | Providing & fixingPTMT towel ring trapezoidal shape 215 mm long 200 mm wide with minimum distance of 37 mm from wall face with concealedfittings arrangement of approved quality and colour weighing not less than 88 gms |
| 107 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.Internal work - Exposed on wall |
| 108 | 20 mm nominal outer dia pipes |
| 109 | 25 mm nominal outer dia pipes |
| 110 | 40 mm nominal outer dia pipes |
| 111 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. |
| 112 | 15 mm nominal outer dia pipes |
| 113 | 20 mm nominal outer dia pipes |
| 114 | 25 mm nominal outer dia Pipes |
| 115 | Providing and fixing of gun metal gate valve with CI wheel of approved quality (screwed ends) |
| 116 | 25mm dia, nominal bore |
| 117 | 32 mm dia, nominal bore |
| 118 | 40 mm dia, nominal bore |
| 119 | 50 mm dia, nominal bore |
| 120 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : |
| 121 | 25 to 40 mm nominal bore |
| 122 | 50 to 80 mm nominal bore |
| 123 | Providing and fixing uplasticised PVC connection pipe with brass unions : 15 mm nominal bore |
| 124 | Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work (internal work -exposed on walls) |
| 125 | 20 mm nominal outer dia pipes |
| 126 | 25 mm nominal outer dia pipes |
| 127 | 32 mm nominal outer dia pipes |
| 128 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : |
| 129 | 20 mm nominal bore |
| 130 | 25 mm nominal bore |
| 131 | Providing and fixing C.P. brass bib cock of approved quality confirming to IS:8931 15mm nominal bore |
| 132 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15mm nominal bore |
| 133 | Providing and fixing C.P.brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 a) 15 mm nominal bore. 15mm nominal bore |
| 134 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. |
| 135 | Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth including consolidating each deposited layers by ramming, watering etc. stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50m : |
| 136 | Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia. |
| 137 | Supply and fixing of UPVC S.W.R. pipe type -B confirming to IS- 13592 including jointing the pipes with rubber ring, lubricant and UPVC SWR cuplar confirming to IS - 14735. Also including excavation of trenches cutting of walls and holes and repairing the walls floors and refilling the trenches as before but excluding supply and cost of other fittings such as elbow, bead, tee and Y-tee including supply of all material labour and T&P .Required for proper completion of the work. 160 mm O.D. |
| 138 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design :160/150 mm diameter pipe |
| 139 | Supply and fixing of UPVC S.W. R. Gully trap confirming to IS - 14735 size 150x110 mm dia of self cleaning design including fixed brick Masonary chamber 250x250x250mm Size i/ c supply and fixing of CI cover with frame weight not less then 4.50Kg. & CI grating 150x150mm complete in all respects. |
| 140 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) Fisnihed with a floating coat of neat cement complete as per standard design : |
| 141 | (a) Inside size 900 x 800mm and 500mm deep including C.I. Cover frame. |
| 142 | (b) Inside size 1200 x 1200mm and 1.0meter deep including C.I. Cover frame. |
| 143 | SEPTIC TANK & SOAK PIT |
| 144 | Excavationin foundation in ordinary soil (loam,clay or sand )including lift up to 1.5m and lead up to 30 m and including filling watering and ramming of exacavation earth into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth adirected by the engineer in charges up to a distance of 30m.from the foundation trenches |
| 145 | In all kind of soil upto 1.5m depth |
| 146 | In all kind of soil upto 1.5m to 3.0m. depth |
| 147 | Cement Concret with 4 cm guage approved stone ballast Approved coarse sand and cement in proportion of 8:4:1 including supply of all material ,labour and t&p etc.required for completion of work |
| 148 | Brick work with brick of class designation 150 in foundation and plinth in cement mortar (1 cement : 4 coarse sand) |
| 149 | R.C.C. workwith cement approved coarse sandand2cm. (3/4\") guageapproved stone grit in the proportion 1:1.5(1cement :1.5 coarse sand :3 aggregate) in lintels of doorsand windows excluding reinforcement and its fixing and binding the same with 24 B WG bindingwireand including necessary centeringand shuttering etc.and also including supply of all materials,labour andtools andof all materials,labour andtools andplants etc, required forproper completion of the works. strength of the concrete shall not beless than M-200. |
| 150 | Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work(whennot includedin anover all rates )wroughttorequired shape as necessary including bending for proper completion of thework. |
| 151 | 15mm cement plaster on rough side of mix 1:4 (1 cement : 4 coarse sand) |
| 152 | Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars. |
| 153 | Providing and fixing C.I. tee at the inlet and outlet of septic tank. |
| 154 | Providing & fixing 75mm dia vent pipes. |
| 155 | Providing & fixing of 75mm dia cast iron terminal guard. |
| 156 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.M.D. -10- Circular shape 500mm internal diameter |
| 157 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks M-150 |
| 158 | RAIN WATER HARVESTING |
| 159 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil |
| 160 | 1.50 mtrto 3.0 mtr |
| 161 | 3.0 mtr to 4.50 mtr |
| 162 | Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. |
| 163 | R.C.C. work with cement approved coarse sand and 2 cm (3/4\") gauge approved stone ballast in the proportion of 1:1.5:3 in SLABS excluding supply of reinforcement and its binding but including its fixing and binding the same with 24 B.W.G.G.I Binding wire and including necessary centering and shuttering etc. and also inclduing supply of all materials, labour & T&P etc. required for proper completion of the work. Binding wire cost beingincluded in this item |
| 164 | M-150 brick work in 1:6 (one cement and six coarse sand sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. |
| 165 | P/F Fe-500 Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. |
| 166 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level. 400 mm dia |
| 167 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 200 mm nominal size dia |
| 168 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, onforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 200 mm nominal size dia |
| 169 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 170 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-incharge. |
| 171 | Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. |
| 172 | Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineerin- charge. |
| 173 | Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in pproved laboratory, i/c disinfection of ubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per uirement and direction of Engineer-in-charge. |
| 174 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia |
| 175 | Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 200 mm dia |
| 176 | Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design. With 20x20 mm square bar |
| 177 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil |
| 178 | Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia. |
| 179 | Providing, laying and jointing P.V.C. pipes including testing of joints etc. complete : 150 mm dia pipe |
| 180 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round R.C.C pipes including bed concrete as per standard design :150 mm diameter R.C.C pipe |
| 181 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 coarse sand (Zone III) : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: |
| 182 | Inside dimensions 600x 850 mm and 45 cm deep for pipe line with three or more inlets : |
| 183 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 184 | Constructing brick masonry road gully chamber 50x45x60 cm with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : |
| 185 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 186 | ELECTRIFICATION WORKS |
| 187 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C |
| 188 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 189 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 190 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 191 | 2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 192 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 193 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm |
| 194 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. RJ45 socket cat 6 with shutter |
| 195 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm) |
| 196 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 197 | Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. |
| 198 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. |
| 199 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). |
| 200 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \"C\" curve including connections, painting etc. as required. |
| 201 | Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A \"C\" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 202 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A \"C\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 203 | Supplying and fixing 63 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A \"C\" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 204 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 205 | 6 way (4 + 18), Double door |
| 206 | 8 way (4 + 24), Double door |
| 207 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 208 | Single pole |
| 209 | Double pole |
| 210 | Triple pole and neutral |
| 211 | Supplying and fixing 40/63A rating, 415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of Four poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Similar to Legrand DX3 AC MCBs or equivalent. |
| 212 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. |
| 213 | 100 mm width X 50 mm depth X 1.6 mm thickness |
| 214 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 215 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 216 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 217 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 218 | Brush Less Direct Current (BLDC) Motor Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req |
| 219 | 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 220 | LED Flood Light, powder coated pressure die cast aluminum (System lumen efficacy 105 <120 lm/Watt) Supplying,nstallation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP- 66,IK-10, CRI >80 , under voltage and over voltage protection, EMIEMC as per CISPR -15 , lenses for beam angle 30 deg-120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolationIES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power |
| 221 | consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy 105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). |
| 222 | 50 watt |
| 223 | Supply installation testing and commissioning of 400mm sweep wall fan. Similar to Crompton Renesa or equivalent. |
| 224 | LED Down lighter (COB Type) (System lumen efficacy ≥120 lm/Watt ) Supplying, installation, Testing & Commissioning of LED Recessed / surface Down lighter (Round / square/ Rectangular) COB Type of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), life time of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ |
| 225 | Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. \"complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector |
| 226 | 12 -15 watt |
| 227 | Online UPS - Input supply: Single Phase, Output Supply : Single Phase Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends ,CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). |
| 228 | Manufactures Word Mark/ Name Engraved/ Embossing/Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm) CRCA Sheet Body (Thickness ≥ 0.50 mm) 36 watt |
| 229 | S/I/T/C of 24 port 10/100/1000 Base T Standalone Gigabit Switch Make Dlink/Amp with active and passive components, punching, complete in all respect |
| 230 | Supplying, installing, testing and commissioning of 6 U wall mount rack with fans , 2 cable managers , satationary shelf , 2 Nos of hardware pkts. |
| 231 | Supply installation testing and commissioning of 2m long Cat-6 patch cord as required. |
| 232 | Supply , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R- 407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. |
| 233 | The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). Inverter Type - Cooling only |
| 234 | 1.5 TR with 5 Star BEE Rating |
| 235 | Supply and Fixing of Voltage Stablizer 04 KVA Rating (90V-280V) |
| 236 | Supply Installation testing and commissioning of Projector system with Inputs : 2 x HDMI;1 x VGA; 1 x HDBaseT; 1 x 3G-SDI; 1 x DVI-D. Control : RS232, Ethernet. with short throw lens complete with all standard accessories and screen. |
| 237 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.1 Run of Cable |
| 238 | Supplying, installing, testing and commissioning of 24 port CAT6 jack panel loaded as per the connections required in jack panel. |
| 239 | Supplying, installing, testing and commissioning of I/O(Information outlet ) for CAT6 Cable termination |
| 240 | Supplying, installing, testing and commissioning of 6 U wall mount rack with fans , 2 cable managers , satationary shelf , 2 Nos of hardware pkts. |
| 241 | Supplying, installing, testing and commissioning of 24 10/100/1000BASE-T PoE-plus |
| 242 | SITC of 2 MP IR Fixed Dome Network Camera -1/2.7″ Progressive Scan CMOS, 1920 × 1080 at 25fps, 2.8 mm Fixed lens, 0.002Lux at F1.4, 0 Lux with IR on, ICR, ONVIF (PROFILE S, PROFILE G, PROFILE T), support H.265, H.264, MJPEG, 120db WDR, 3D Digital Noise Reduction, Three individually configurable stream, 12 VDC & PoE, IR range: 40m, Support on-board storage up to 256 GB (SD card not included), IP67, Edge Analytics- Line crossing detection, Intrusion detection, Motion detection, Video tampering, UL, CE, FCC certified. |
| 243 | SITC of 2 MP IR Fixed Bullet Network Camera -1/2.7″ Progressive Scan CMOS, 1920 × 1080 at 25fps, 2.8 mm Fixed lens, 0.002Lux at F1.4, 0 Lux with IR on, ICR, ONVIF (PROFILE S, PROFILE G, PROFILE T), support H.265, H.264, MJPEG, 120db WDR, 3D Digital Noise Reduction, Three individually configurable stream, 12 VDC & PoE, IR range: 40m, Support on-board storage up to 256 GB (SD card not included), IP67, Edge Analytics- Line crossing detection, Intrusion detection, Motion detection, Video tampering, UL, CE, FCC certified. |
| 244 | SITC of32 channel Network Video StoragE NVR suitabe to access data from any remote location including backup drive for 30days. |
| 245 | Supplying, installing, testing and commissioning of HDMI to HDMI Cable. |
| 246 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25mm Dia |
| 247 | Supply Instalation Testing and commissioning of standalone type water cooler having SS body with all required accessories as required. |
| 248 | Design, Manufacturing, Supply, Commissioning & Testing of Main LT Panel. The panel will be totally enclosed type with, free standing, floor mounted, indoor duty, dust & vermin proof, , front operated, electrical panel fabricated from 2 mm thick M.S. Sheetas per specifications & drawing laid in this document and will be complete with the main and auxiliary bus bars, multimeter, indication lamps, CT\"s, protection MCB, interconnection wiring, earth bus and will be powder coated finish with 50 micron thickness. |
| 249 | The Main LT Panel shall use all breakers suitable for 415 V AC, 3 phase, 50 Hz, 3 phase 4 wire supply system. All having following incomming and outgoing Air Circuit Breakers, FSU\"s as per the drawing and specification. Each incoming breaker will have microprocessor based releases and all outgoing breaker will have minimum electrostatic releases over 250A & thermal magnetic release below 250A. The Panel will be made as per detailed specifications & drawings forming part of this document. Fault level of panel shall be 35 MVA. |
| 250 | INCOMMER |
| 251 | 250Amp. 16KA FP With S/C, U/V, E/F Protection MCCB-1 no. (From Transformer) |
| 252 | 250Amp. 16KA FP With S/C, U/V, E/F Protection MCCB-2 no. (From DG Set) |
| 253 | BUS COUPLER |
| 254 | 1 Nos. 250 Amp FP ATS |
| 255 | BUSBARS |
| 256 | 1 Nos. 300 Amp FP busbars of aluminium alloy as per SLD. |
| 257 | OUTGOING |
| 258 | 32Amp. 16KA FP MCB12 No. |
| 259 | 63Amp. 16KA FP MCB12 No. |
| 260 | 125Amp. 16KA FP MCB 6 No. |
| 261 | INSTRUMENTS |
| 262 | 2 sets of multifunction meter with parameter current,voltage,KWH,KVAH,Power factor on incoming from transformers. |
| 263 | 2 Sets of phase indicating lights (RYB) with protection fuses (one set for each incoming breaker). |
| 264 | 2 Sets breaker \"ON\" & \"OFF\" indicating lamp (one set for each incoming breaker). |
| 265 | 2 Sets auto trip indicating lamp . |
| 266 | Supplyof Power Cables,Solid Aluminum conductor up to 10 sqmm balance stranded conductor,XLPE Insulated,cores laid up, PVC tape inner sheathed, unarmoured/Armour(Aluminium wire for single core up to 70 sqmm balance Aluminium strip, Glavanised wire for cables upto 2x16 sqmm, 3x10 sqmm & balance all galvanised steel strip),extruded PVC Type ST2 sheathed,650/1100V grade as per IS 7098(Part 1) 1988 |
| 267 | 4CX6Sq.mm Cable |
| 268 | 3.5CX35Sq.mm Cable |
| 269 | 3.5CX240Sq.mm Cable |
| 270 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 271 | 4 X 10 sq. mm (25mm) / 4 X 6 sq. mm (25mm) |
| 272 | 3½ X 35 sq. mm (32mm) |
| 273 | 3½ X 240 sq. mm (62mm) |
| 274 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 185 sq. mm and upto 400 sq. mm |
| 275 | Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 185 sq. mm and upto 400 sq. mm |
| 276 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 277 | EXTERNAL PLUMBING WORKS |
| 278 | Providing & fixing G.I. pipes complete with G.I. fittings includingtenching and refilling etc. (external work) 40mm nominal bore. (Horticulture line) |
| 279 | Providing and fixing gate valve (with cap complete with bolts, nuts, rubber insertion etc. 40mm nominal bore. |
| 280 | Constructing brick masonry chamber 600 x 600x750mm insidewithF.P.S. brickwork in cement mortar 1:4 (1 cement : 4 coarse sand) for Sluice Valve / Air Valve, with C. I. surface box 100 mmtop diameter, 160 mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slabwith 1 : 2 : 4 mix (1 cement : 2 coarsesand : 4 gradestone aggregate 20 mm nominal size); necessary excavation,foundationconcrete 1:5:10 (1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size) and inside plasteringwithcement mortar 1 : 3 (1 cement : 3 coarsesand ) 12mmthick finished with a floatingcoatofneat cementcomplete as per standarddesign |
| 281 | EXTERNAL ELECTRIFICATION WORKS |
| 282 | Earthing with GI earth pipe, 600 mm X 600 mm X 6 mm thick including accessories and providing masonary enclosure withcover platehavinglockingarrangement and watering pipe of 2.7 metre long etc, with charcoal/cock and salt as required. |
| 283 | Supplying and Laying of 25 mm X 3 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection / terminating with nut, bolt, spring, washer etc. as required.( jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 284 | Supplying and Laying of 6 SWG G.I wire at 0.50 metre below ground level for conductor earth electrode, including connection / terminating with G.I. thimble etc. as required. |
| 285 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and refilling etc as required. 100 mm Dia |
| 286 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. |
| 287 | Upto 35 sq. mm |
| 288 | Above 35 sq. mm and Upto 95 sq. mm. |
| 289 | Supplying & making end termination with brass compression gland and aluminium lugs for the following size of PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 290 | 2 X 6 sqmm. (19mm) |
| 291 | 2 X 10 sqmm. (19mm) |
| 292 | 4 X 16 sqmm. (28mm) |
| 293 | 3.5 X 70 sqmm. (38mm) |
| 294 | Supply of following size of 1.1 KV grade multicore aluminium conductor PVC sheathed armoured cable as per IS 1554. |
| 295 | 6 sqmm 2.0 core |
| 296 | 10 sqmm 2.0 core |
| 297 | 16 sqmm 4.0 core |
| 298 | 35 sqmm 3.5 core |
| 299 | 70 sqmm 3.5 core |
| 300 | Supply, installation, testing and commissioning of external post top lantern with follong and complete as required. |
| 301 | 6m high(5.0m above ground) 65mm dia GI pole as approved, adopting socket at top for fixture mentioned below, base plate 300x300x6mm and provision for mounting junction box etc.-1 set |
| 302 | Erection of pole in cement concrete 400x400x1000mm deep 1:3:6 ratio cement concrete foundation including excavation, refilling, secured with holding clamps, bolts, nuts, alighnment of poles casting etc. including 100 mm thick lean concrete shall be provided at the bottom. |
| 303 | LED type 50 watt(street light) fittings of all types with all accessories. |
| 304 | Suitable size control box with 1 no. incoming and 2 nos. outgoing terminals and 2 nos. tap-out terminal with 1 no. 5A hrc fuses complete.-1set |
| 305 | Suitable number(S) 40mm dia class-B GI Pipes from above control box to upto 0.5 meter below ground level for power cable entry. |
| 306 | C.C. ROAD WORKS |
| 307 | EarthworkinExcavationintrenchesforfoundationspipes cable etc in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto50 meter and includingfilling, wateringandrammingofexcavatedearthdisposalofsur-plus earthas directedby the Engineerinchargeup to a distance of 50 meters from the foundation trenches. |
| 308 | Preparationandconsolidationofsubgradewithpowerroad rollerof8to12tonnecapacityafterexcavatingearthtoan average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith leadupto 50 metres. |
| 309 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 310 | Providingandlaying incementconcrete1:4:8(1cement : 4 coarsesand:8gradedStoneaggregate20mmnominalsize) andcuringcomplete,including costof form-work,in foundation and floors. |
| 311 | M-150brickworkin1:4(onecementandfourcoarsesand sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. |
| 312 | R.C.C.workwithcementapprovedcoarsesandand20mm. guageapprovedstoneballastintheproportionof1:1.5:3(M- 20) in slab excluding supply of reinforcement and its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc.and also includingsupplyofallmaterials,labourandtoolsandplants etc, required for proper completion of the works. Binding wire cost being inluded in the item. M-20 |
| 313 | Providing and laying in position bitumen hot sealing compound for expansion joints etc. Using grade \"A\" sealing compound. |
| 314 | FIRE FIGHTING SYSTEM |
| 315 | Supply & fixing of fire extinguisher, ABC Type 4.00 kg. capacity(ISI Marked IS:15683 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 316 | Supply & fixing of CO2 type fire extinguisher,4.5 kg. capacity(ISI Marked IS:2878 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 317 | SUBMERSIBLE PUMP WITH BORING |
| 318 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. 300 mm dia |
| 319 | Supplying, assembling, lowering and fixing in vertical position in bore well,unplasticized PVC medium well casing (CM) pipe of required dia,conforming to IS: 12818, including required hire and labour charges, fittings& accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia |
| 320 | Supplying, assembling, lowering and fixing in vertical position in bore wellunplasticized PVC medium well screen (RMS) pipes with ribs, conformingto IS: 12818, including hire & labour charges, fittings & accessories etc.all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia |
| 321 | Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. (3.14X.150X.150-3.14X.05X.05)X90 |
| 322 | Providing and fixing suitable size threaded mild steel cap or spot weldedplate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 150 mm nominal size dia |
| 323 | Providing and fixing M.S. clamp of required dia to the top of casing/housingpipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts required size complete. 150 mm nominal size dia |
| 324 | Providing and fixing Bail plug/ Bottom plug of required dia to the bottomof pipe assembly of tubewell as per IS:2800 (part I). 150 mm nominal size dia |
| 325 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 32mm dia nominal bore |
| 326 | Supply and Installationof 3.0 HP Submirssible pump& panel board etc.+ |
| 327 | Water supply tanker of 5000 litre capacity |
| 328 | Supply and fixing of nylon jali around the slotted pipescomplete as required. |
| 329 | Supply and steel wire rope of 1/2\" size |
| 330 | Transpolation of boring tools other required euipment and installation of site |
| 331 | Supply and fixing of finolex of copper cable ISI marked submersible cable of size 4 sq mm 3 core |
| 332 | CARTED EARTH FILLING |
| 333 | Filling of Carted earth in plinth in 20cm layer including leveling, dressing and watering and also including of supply of earth including carted loading & unloading as per direction of Engineer incharge.. |
| 334 | SIGNAGE WORKS |
| 335 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab colour black, Cherry/Ruby red, Area of slab over 0.50 sqm |
| 336 | Fixing for signage. |
| 337 | In graving of latter in granite of for signage. |
| 338 | SPLIT AIR CONDITIONING SYSTEM |
| 339 | Supplying installation ,testing and commissioning of energy efficient Split Air Conditioner with MCB. 1.5 Ton Split AC (Proper water drainage) 5 Star Rating with Stanard Specification as per detailed estimate complete. |
| 340 | GST Extra as applicable |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy