Construction Of G Plus 3 Storied Building For 50 Beded Critical Care Block At Malda Medical College And Hospital, Malda-Supply Installation Testing And Commissioning Of Ups, Malda-West Bengal
TDR : 49311505
Tender Notice
BOQ
Expired
Malda
West Bengal
Construction Of G Plus 3 Storied Building For 50 Beded Critical Care Block At Malda Medical College And Hospital, Malda-Supply Installation Testing And Commissioning Of Ups
Name of Work: Construction of G+3 Storied Building for 50 beded Critical Care Block at Malda Medical College and Hospital, Malda - SITC of UPS. (Job No. 04 / M / OW of 2025 – 26).
Sl. No.
Item Description
1
SITC of 30 KVA UPS including Battery Bank of (21371 ~ 24960)VAH or higher(SMFBattery 12Volt, 45AH ~125AH)3ph Input /3ph Output, Staticby-pass arrangement, compitable with D.G.Set, DSP controlled IGBT based rectifier with minimum 90% efficiency on100% Load.The UPSshallbeprovided withactiveinputP.F.Correctionsystemtoobtain0.9 lagat 100%resistive Load,Waveform-Pure sine wave. Crest Factor- 3:1ItShouldbecapableofoperatingin50\"cabove ambient temprature, Built in Solid Statefloatcum boostchargerwithautomaticboost / trickelcharge mode with current Limiting features. The charger shouldbe designed for atleast 15% of the total battery current.TheUPSShouldhavecurrentlimiting protection, builtinoverload/ Shortcircuitprotection with snubber circuits for current limit. Soft start arrangement,Overvoltage /undervoltageprotection, mainsON,Inverter ON/ OFF/ FAULTY/ TRIP (Reason),ChargerON/FAULTYor TRIP, Battery Low, Staticby-passON,Overtemperature. Inbuilt Isolation Transformer of 1:1 ratio connected in Delta- Star Mode. Battery set Complete with self-standing cubicle or cabinet. The UPS should have external automatic load transfer switch for parallel operation.
2
RegulatedSealedLead AcidBattery, Construction type : AGM or VRSLAB inABSFlameRetardantRating (12V SMF Battery - 45AH ~125AH) (BatteryMake Amararaja /Quntra/Exide Power Safe. Back-uptime: 30Min at full load. Warranty:OneYearonUPSand One Year on SMF Battery on-site against any manufacturing defects. Certificate : ISO 9001:2015, ISO 14001:2015, ISO18001,OHSAS 18001. CE Certification:IEC/ EN62040-1-1, IEC/EN50091- 1,IEC/EN60950(Safety),IEC/ EN 5009 I-2,IEC/ EN 62040-2 (EMC Emmission), IEC/EN 62040-3 (Performance &Design), IEC/EN61000-4(EMC Emmunity)&IEC/ EN60146(Design&Manufacture) Make: APC-SchneiderElectric /NUMERIC/Power One/VERTIV/SwitchingAVO/Powersafe/Delta/Better Power/ Prostarm.
3
TERMS & CONDITIONS
4
(i) Rate should be quoted inclusive of all applicable taxes and Duties etc including GST.(ii) All materials, equipments & accessories must conform to relevant IS / IEC specifications.(iii)Necessary manufacturer\"s warranty certificate will have to be submitted during delivery of the material.
We takes all possible care for accurate & authentic tender information, however Users
are requested to refer Original source of Tender Notice / Tender Document published by
Tender Issuing Agency before taking any call regarding this tender.