| 1 | Replacement/maint. of5A switch/socket in the existing switch board. |
| 2 | Replacement / maint. of fan regulator of ceiling fan in the existing switch board/ceiling fan. |
| 3 | Supply, fixing and commissioning of 5 amp.220 Vcombined switch-socketwith 4 inch X 6 inch wooden switch boardwith bakelite cover with white surface of minimum 3 mm thickness. |
| 4 | Supply of 4 inch X 6 inch wooden switch boardwith bakelite cover with white surface of minimum 3 mm thickness and with 5 amps, 220 V combined switch socket. |
| 5 | Supply, fixing and commissioning of 5 amp, 220V switch with 4 inch X 4 inch wooden switch board with bakelite cover with white surface of minimum 3 mm thickness. |
| 6 | Supply of 4 inch X 4 inch wooden switch board with bakelite cover with white surface of minimum 3 mm thickness and with 5 amps,220 Vswitch. |
| 7 | Wiring for circuit / submain wiring along with earth wire with 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. This includes supply of 2.5 sq. mm. PVC insulated stranded single core copper cable, 20 mm dia. ISI marked, PVC conduit, 20 mm PVC bends, 20 mm PVC couplers, 20 mm iron staples/ saddles/ screws, PVC fastener 40mm long, Cement, paint, sand etc. as required (Make of cable: Havells / Polycab / Mescab / Finolex / KEI / Microtek / VGuard / RR (cable and PVC Conduit shall be approved by UCIL before installation) |
| 8 | Wiring for circuit / submain wiring along with earth wire with 2 X 4 sq. mm + 1 X 4 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. This includes supply of 4.0 sq. mm. PVC insulated stranded single core copper cable, 20 mm dia. ISI marked, PVC conduit, 20 mm PVC bends, 20 mm PVC couplers, 20 mm iron staples/ saddles/ screws, PVC fastener 40mm long, Cement, paint, sand etc. as required (Make of cable: Havells / Polycab / Mescab / Finolex / KEI / Microtek / VGuard / RR (cable and PVC Conduit shall be approved by UCIL before installation) |
| 9 | Supply and laying of2X 1/c x 2.5 sq. mm PVC insulated ,1100 Volt grade stranded flexible copper conductor cable + 1 x 1/c x 1.5 sq. mm copper conductor for earthing throughthrough PVC casing capping of width 25/35mm of ISI mark. (size of casing caping) |
| 10 | Complete overhauling of ceiling fan. This includes cleaning and greasing of ball bearing/replacing of defective bush / bearing.( only bearings shall be supplied by UCIL). Rewinding of fan not included. |
| 11 | Dismantling/ installation with commissioning of ceiling fan. This include disconnection/connection of circuit also. |
| 12 | Maintenance and cleaning of tube light fitting with replacement of defective parts like choke ,tube light holder,base and stator holder and checking ofinternal wiring etc.This includes checking of main line electrical circuits (other than internal wiring of tube light fitting.) |
| 13 | Installation ,connection & commissioning (through controling switch)of tube light fitting (single /double T/L fitting) on wall/structure etc with wooden round block /4X4Inch wooden block . (wiring in running meter not included butwooden block shall be in the scope of bidder) |
| 14 | Replacement / maintenance of 15 A power point in the existing switch boards. |
| 15 | Supply of switch board of size8 inch X 10 inch / 6inch X 8 inch. The switch board shall be well finished made from CRCA sheet steel of 2 mm thickness duly painted and with electrical grade bakelite cover with white surface. of minimum 3mm thickness. Note:- This includescutting in cover for fixing switches |
| 16 | Complete maintenance of feeder pillar box. This includes cleaning and tightening andchecking of all lineparts andreplacement of defective items. |
| 17 | Replacement offuse /fuse wire in LDB/PDB |
| 18 | Replacement of ELCB in the MDB/ LDB. This includes tightening and checking of all line parts/circuits also. |
| 19 | Replacement / maint. of MCBs of power distribution boards(PDB)/lighting distribution board (LDB)This includes tightening andchecking of all line parts. |
| 20 | Installation and commissioning of exhaust fan of up to size 350 mm dia .This includes cutting of wall andfinishing and supply of hardware like nut,bolts etc.only exhaust fan shall be supplied by UCIL) |
| 21 | Checking and maintenance of exhaust fans. This Includes dismantling, cleaning, replacement of bearing/bushing, assembling and paiting.(Only bearing shall be supplied by UCIL) |
| 22 | Maint. of flood light fittings/ Halogen light fitting on building, structures, pole etc. This includes replacement of defective parts like holder/lamp and proper fixing of the above. The ladder will be provided by M/s UCIL. Transportation of ladder etc has to be done by contractor from one site to another. |
| 23 | Maintenance ofstreet light fitings (70watt /150watt HPSV/HPMV lamp fittings or LED light fittings). This includes cleaning, tightening and replacement of defective items like bulb / choke, igniter, capacitor, holder etc. and fixing of bracket on lighting poles also including maintenance |
| 24 | Maintenance and replacement of photo cell and associated circuits This includes proper setting of photo cell, cleaning and tightness checking of associated circuits including contractor and switch fuse unit. |
| 25 | Maintenance of lighting protection system and earthing system including Refixing/fixing of 8 SWG GI wire(Measurement in meter) |
| 26 | Maintenance of lighting protection system and earthing system including Refixing/ fixing of air terminal |
| 27 | Laying of 3/4 core x 120/185/300 sq.mm Al cable (in meter) in trench of 750mm deep and 400mmin single tire formation including excavation, back filling and cable protection with sand and bricks (16 Nos. of bricks per meter). This includes supply of brick and sand also. (quality of sand and bricks shall be approved by UCIL before use at site) |
| 28 | Laying of 3/4 core 10/16/25/50/95 sq, mm Al cable (in meter) in trench of 750mm deep and 400mmin single tire formation including excavation, back filling and cable protection with sand and bricks (16 Nos. of bricks per meter). This includes supply of brick and sand also. (quality of sand and bricks shall be approved by UCIL before use at site) |
| 29 | Laying of 1.1 KV gradePVC insulated 3/3 & 1/2/4 corearmoured Aluminium conductor cableof size up to 50/70 sq.mmin underground trench /cable tray with supply of aluminum clamps, nuts, bolts etc.(Note: Fabrication of the cable trays and construction of cable trench are not included in the above scope.) |
| 30 | Laying of 1.1 KV grade PVC insulated 3/3 & 1/2/4 core x 120 / 150 / 185 / 300 sq mm. armoured Aluminium cable in underground trench /cable tray with supply of aluminum clamps, nuts, bolts etc.(Note: Fabrication of the cable trays and construction of cable trench are not included in the above scope.) |
| 31 | 6.6 KV overhead line maintenance. This includes Replacement of pin insulator |
| 32 | 6.6 KV overhead line maintenance. This includes Replacement of Air Break switch |
| 33 | 6.6 KV overhead line maintenance. This includes Replacement of post insulator/lightening arrestor |
| 34 | 6.6 KV overhead line maintenance. This includes Replacement of disc insulator. |
| 35 | Installation of street light poles with lighting fixture (LED / HPSV lamp / Mercury lamp / Halogen lamp fitting). This includes supply and erection of all materials required for cement concrete foundation. This also includes fixing of junction box,painting,marking,fixing of earth spike of 32 mm dia and 2.5mtrs long M.S rod with necessary connection of lighting fixture with 2.5 sq .. PVC stranded copper conductor cable from light fitting to junction box..(Light fittings, street light poles and junction boxshall be supplied by UCIL) |
| 36 | Installation of street light fixture on wall/building/structure etc. This includes connection/transportation of light fittings & its accessories also. |
| 37 | Supply and placement of well finished storage / Distribution Board / Starter Panel enclosure with locking facility made from CRCA sheet steel of minimum 1.6-2 mm thickness, Size: 2000 x 900 x 550 (H x W x D). This shall have to be approved by UCIL before supply |
| 38 | Installation of stay set complete in all respects. This includes supply and erection of all materials required for cement concrete foundation. |
| 39 | Installation of ACSR DOG (in meter) conductor including transportation andtensioning of DOG conductor and supporting& fixing on insulators including binding as required. |
| 40 | Supply of two (02) skilled men (min ITI/NCVT (Electrical) & license holder with minimum two years experience in electrical related jobs. The jobs include material shifting, tool & tackles shifting from one site to other site, cable glanding,cable socketing,cable termination and other electrical related jobs.(Note: Supply of 1 skilled men = 1 manday. Therefore supply of 2 skilled man for 305 days = 2 x 305 = 610 mandays) |
| 41 | Supply of six (06) semiskilled men (min. ITI / NCVT(Elect.) & license holder / exp. of minimum 02 years) as electrical fitter. Persons shall have minimum two years experience in motor overhauling, bearing replacement and other electrical fitting jobs.(Note: Supply of 1 semiskilled man = 1 manday. Therefore supply of 6 semiskilled man for 305 days = 6 x 305 = 1830 mandays) |
| 42 | Cable terminal finishing including equipment connection and supply of double compression type gland and lugs for cables up to 3/4 core 16 sq.mm. of 1.1 KV grade PVC insulated armoured stranded aluminum conductor cable of following size. (Acceptable Makes: COMET / DOWELLS / CONNECTWELL / GRIPON / BRACO only) |
| 43 | Cable terminal finishing including equipment connection and supply of double compression type gland and lugs for cable of size 4 core 25 sq.mm. of 1.1 KV grade PVC insulated armoured stranded aluminum conductor cable of following size. (Acceptable Makes: COMET / DOWELLS / CONNECTWELL / GRIPON / BRACO only) |
| 44 | Cable terminal finishing including equipment connection and supply of double compression type gland and lugs for cable of size 3.5 core50/70 sq.mm.of 1.1 KV grade PVC insulated armoured stranded aluminum conductor cable.of following size. (Acceptable Makes: COMET / DOWELLS / CONNECTWELL / GRIPON / BRACO only) |
| 45 | Cable terminal finishing including equipment connection and supply of double compression type gland and lugs for cable of size 3.5 core 120/150 sq.mm. of 1.1 KV grade PVC insulated armoured stranded aluminum conductor cable.of following size. (Acceptable Makes: COMET / DOWELLS / CONNECTWELL / GRIPON / BRACO only) |
| 46 | Cable terminal finishing including equipment connection and supply of double compression type gland and lugs for cable of size 3.5 core 185 sq.mmof 1.1 KV grade PVC insulated armoured stranded aluminum conductor cable.of following size. (Acceptable Makes: COMET / DOWELLS / CONNECTWELL / GRIPON / BRACO only) |
| 47 | Cable terminal finishing including equipment connection and supply of double compression type gland and lugsfor cable of size 3.5 core 300 sq.mm of 1.1 KV grade PVC insulated armoured stranded aluminum conductor cable.of following size. (Acceptable Makes: COMET / DOWELLS / CONNECTWELL / GRIPON / BRACO only) |
| 48 | Replacement of 150/250 watt 220 volts HPSV lampfo medium bay and high bay type light fitting. Light fittings talled at a height up to 10.5 meters and upto 20 meters(approx). Lamps shall be supplied by UCIL |
| 49 | Maintenance of 150/250 watt ,220 volts HPSV lamp fitting(High bay and meium bay tipe).This includes replacement of defective parts like lamp,choke,ignitot ,condensor,holder etc and repairing of internal wiring. This also includes cheking and repairing of lighting circuit from lightuing DB to lamp fitting including removal and refixing of lamp fitting.Note: These light fitting are installed at a heigt of upto 20 metresteel structures near ceiling of the buildings. All spares parts shall be supplied by UCIL. |
| 50 | Construction of earth pit with GI pipeas per IS: 3043 with latest amendments.This includes supply of all materials required for construction of earth pit and interconnections byGI flat of size 50 x 6mm.This also includes construction of brick chamber and cover by chequired plate of 8mm thick for earth pit inclusive of all matewrials. This does not includesupply of GI flat. |
| 51 | Supply of Mild Steel (M.S.) structures required for erection of MCCpanels, PDB Panels etc. andmaking of cable trays as per requirement. (Note: For channel ISMC 75, 100, 125, 150,For angles 65 x 65 x 8, 50 x 50 x 6, 40 x 6 to be considered and for plate 6/8/10 mm to be considered however exact size willbe decided at the time of carrying out jobs and as per requirement) |
| 52 | Fabrication of Mild steel structures required for erection of MCCpanels, PDB Panels etc. andmaking of cable trays as per requirement. Fabrication shall be done with Channel, angle, pipes, plates etc. (Note: For channel ISMC 75, 100, 125, 150,For angles 65 x 65 x 8, 50 x 50 x 6, 40 x 6 to be considered and for plate 6/8/10 mm to be considered, however exact size will be decided at the time of carrying out jobs and as required for erection of panels and cable trays and other items as per site condition)(Note: only Extra steel shall be supplied by UCIL. Gas cutter, welding sets welding rods etc shall be in bidders scope) |
| 53 | Erection of push button station includingincluding fixing on steel structure/wall and supply of all hardwares and connections.. (Only push button station will be supplied by UCIL) |
| 54 | Fixing of TPN fuse switch unit up to 63/100 amps. (Make:GE/English Electric) with all fixing hard wares and welding materials This includescable connection to the switch also.canopy shall also be provided for protection from rain water.(TPN Fuse switch unit shall be supplied by UCIL) |
| 55 | Removalof 1.1 KV gradePVC insulated 3/3&1/2 corearmoured Alluminium conductor cableof size 6 sq.mm.in underground trench /cable tray with supply of aluminum clamps, nuts, bolts etc.(Note: Fabrication of the cable trays and construction of cable trench are not included in the above scope.) |
| 56 | -do- but cable size 3/3&1/2/4 core, 10/16 sq mm. |
| 57 | -do- but cable size 3/3&1/2 core, 25/35/50 sq.mm. |
| 58 | -do- but cable size 3/3&1/2 core, 70/95 sq mm. |
| 59 | -do- but cable size 3/3&1/2 core, 120/150/185 sq. mm. |
| 60 | -do- but cable size 3/3&1/2 core, 240/300 sq mm. |
| 61 | Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for cable size upto 120 sq. mm. size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required (Acceptable Makes: Raychem / 3M / Honeywell / DuPont only) |
| 62 | Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for cable size upto 240 sq. mm.size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required (Acceptable Makes: Raychem / 3M / Honeywell / DuPont only) |
| 63 | Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for cable size upto 120 sq. mm. size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required (Acceptable Makes: Raychem / 3M / Honeywell / DuPont only) |
| 64 | Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for cable size upto 240 sq. mm. size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required (Acceptable Makes: Raychem / 3M / Honeywell / DuPont only) |
| 65 | Supplying and making straight through joint with heatshrinkable kit including ferrules and other jointing materials for cable size upto 3/3.5/4 Core x 50 sq. mm. of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required (Acceptable Makes: Raychem / 3M / Honeywell / DuPont only). |
| 66 | Supplying and making straight through joint with heatshrinkable kit including ferrules and other jointing materials for cable size upto 3/3.5 Core x 120/150 sq. mm. of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required (Acceptable Makes: Raychem / 3M / Honeywell / DuPont only). |
| 67 | Supplying and making straight through joint with heatshrinkable kit including ferrules and other jointing materials for cable size upto 3/3.5 Core x 185 sq. mm. of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required (Acceptable Makes: Raychem / 3M / Honeywell / DuPont only). |
| 68 | Supplying and making straight through joint with heatshrinkable kit including ferrules and other jointing materials for cable size upto 3/3.5 Core x 300 sq. mm. of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required (Acceptable Makes: Raychem / 3M / Honeywell / DuPont only). |