| 1 | M&L for water proofing treatment to RCC roof slab, including parapet comprising with the following courses of treatment/specification from bottom to top:-(i) Taking out old roof treatment and roughening the same old concrete slab by picking, sweeping clean and washing down with water to remove dust etc.(ii) Screed bed or bedding layer of mortar 15 mm thick in CM 1:4 for laying as in roof slab with mixing of WPC and surface finished fare and smooth without using extra cement. (Note: WPC shall be measured and paid for under separate items)(iii) Cleaning of plastered roof surface and applying one coat of cold bituminous primer @ 0.25ltr /Sqm conforming to IS:3384-1986.(iv) APP based polymeric membrane 3mm thick (minimum),weighing 3.5 Kg/sqm reinforced with polyester non woven fabric (weighing not less than 150 gms/Sqm) shall be less applied over bituminous primer as specified above over aApplication of polymeric membrance shall by torch application. The overlaps shall be minimum 100mm on the transverse direction and 75mm on longitudinal direction.(v) Applying one coat of aluminum paint over the APP modified membrance @ 0.11Kg/sqm. |
| 2 | Demolition of plain cement concrete (unreinforced) Concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed. |
| 3 | M&L for PCC (1:5:10) type E2 (using 40mm graded agg) as in sub base of WC complete all as specified and as directed. |
| 4 | M&L for water proofing treatment to sunken portion of RCC slab with the following courses of treatment/specification :-(i)ForScreed bed or bedding layer of mortar 1:4 in 15 mm thick for laying as in sunken portion with mixing of WPC and surface finished fare and smooth without using extra cement. (Note: WPC shall be measured and paid for under separate items)(ii) Preparationof plastered roof surface and applying one coat of cold bituminous primer @ 0.25 ltr /Sqm conforming to IS:3384-1986.(iii) APP based polymeric membrane 3mm thick (minimum), weighing 3.5 Kg/sqm reinforced with polyester non woven fabric (weighing not less than 160 gms/Sqm) shall be applied by torch application over bituminous primer as specified. The overlaps shall be minimum 100mm on the transverse direction and 75mm on longitudinal direction.Note:-The work of sunken portion treatment shall be got executedthrough expert team of manufacturers or authorised applicator of manufacturer. Contractor shall submit documentary evidence on support of applicator engaged for approval of GE. |
| 5 | Supply only for water proofing compound. |
| 6 | S&F of 0.63 mm thick galvanized corrugated iron (CGI) sheeting with two corrugation side lap sheets having zinc coating @ 120 gram per sqm inclusive of both sides, fixed with coach screws and washers as in roof covering etc including dismantlingany gauge, thickness, including Nainital or similar pattern roof cverings complete all as specified and directed. |
| 7 | S&F 0.63 mm thick Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters,drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 including dismantling any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specifid and as directed. |
| 8 | Refixing only 0.63 mm thick galvanized corrugated iron (CGI) sheeting with two corrugation side lap sheets having zinc coating @ 120 gram per sqm inclusive of both sides, fixed with coach screws and washers as in roof covering etc. including dismantlingany gauge, thickness, including Nainital or similar pattern roof cverings complete all as specified and directed. |
| 9 | S & F Pre- painted galvalume aluminum zinc coating GI based corrugated/semi corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as including dismantling corrugated steel / AC sheeting any gauge, thickness, including Nainital or similar pattern roof cverings complete all as specified and directed. |
| 10 | S & F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as including dismantling plain steel/AC sheetingany gauge, thickness, including Nainital or similar pattern roof cverings complete all as specified and directed. |
| 11 | M&L for Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 all as specified and directed |
| 12 | S&F 2nd class HW boarding 20mm thick fixed with nails as in eaves board planed one side with butt joint including dismantling boarding of any description complete all as specified and as directed. |
| 13 | S&F PVC gutter , Half Round, 180mm size complete all as specified and directed. |
| 14 | S&F Joint Bracket (with 2 clamps), 180mm for PVC pipes (half round) complete all as specified and directed. |
| 15 | S&F Support Bracket, 180mm for PVC pipes (half round) complete all as specified and directed. |
| 16 | S&F Running Outlet (with 2 clamps), 180mm for PVC pipes (half round) complete all as specified and directed. |
| 17 | S&F Stop End Outlet (with 1 clamp), 180mm for PVC pipes (half round) complete all as specified and directed. |
| 18 | S&F PVC Reducer, 180mmx110mm complete all as specified and directed. |
| 19 | Demolition cement Concrete (RCC) of any description and in any position not otherwise specifically provided for complete all as specified. |
| 20 | S & F 500 litres capacity double layer, rotational molded, polythene (white colour), tripple layer water storage tank, ISI Marked (Cylindrical vertical with closed top),colour white ,hoisted and fixed on roof in position, including all fitting such as connection pieces with GI tank nipple for inlet, outlet, washout and overflow etc and including dismantling completeall as specified and as directed. Make : Sintex, Polycon, waterwell. |
| 21 | S & F 1000 litres capacity double layer, rotational molded, polythene (white colour), tripple layer water storage tank, ISI Marked (Cylindrical vertical with closed top),colour white ,hoisted and fixed on roof in position, including all fitting such as connection pieces with GI tank nipple for inlet, outlet, washout and overflow etc and including dismantling completeall as specified and as directed. Make : Sintex, Polycon, waterwell. |
| 22 | S&F in repair 20mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all asspecified and as directed. |
| 23 | S & F 15 mm bore steel water tubing medium grade galvanised with and including all fittings and fixed to walls and ceilings or laid under floors including taking down up or down complete all as specified and directed. |
| 24 | S & F 20 mm bore steel water tubing medium grade galvanised with and including all fittings and fixed to walls and ceilings or laid under floors including taking down complete all as specified and directed. |
| 25 | Refixing 15 mm bore old steel tubing but with newGI fittings after cleaning the pipe, in new or old position( wall, ceiling or floor) including taking up or down complete all as specified and directed. |
| 26 | Refixing 20 mm bore old steel tubing but with newGI fittings after cleaning the pipe, in new or old position( wall, ceiling or floor) including taking up or down complete all as specified and directed. |
| 27 | M&L for Cutting chases, of girth not exceeding 10 cm for concealed water tubing or concealed conduit wiring, etc. in stone / brick masonry wall built in cement mortar and making good, disturbed surface in Cement mortar 1:3 complete. |
| 28 | M&L Non-skid ceramic colour tiles (premium/special quality) 7 to 8 mm thick , (square/rectangular), area of each tiles exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of the tiles over and including 15 mm thick screed bed in cement sand mortar 1:6 including dismanthing floor/hearth or wall tilling including cement mortar bedding but not backing removing serviceable tiles to store and rubbish off premises complete all as specified and as directed. |
| 29 | M & L for Non skid ceramic coloured tiles 7 to 8 mm thick (Square or Rectangular) area of each tile exc. 0.11 Sqm but not exc. 0.18 sqm, as in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface including 15 mm thick screed bed or bedding layer in cement mortar 1:6 for laying floor finishes finished fair and even complete all as specified and directed of tile complete all as specified and directed. |
| 30 | M&LGlazed ceramiccolour tiles of size 450 x 300 x 7mm thick (premium/special quality) in vertical wall etc set and jointed with neat cement slurry and pointed in white or colour cement to match with the colour of tile over and including 10 mm thick backing course in cement sand mortar 1:4including dismanthing floor/hearth or wall tilling including cement mortar bedding but not backing removing serviceable tiles to store and rubbish off premises complete all as specified and directed. |
| 31 | M&L forPCC 1:3:6 type C2 (using 40mm graded agg) as in sub baseincludingdemolition of plain cement concrete (unreinforced) in ground floors and pavings nexc 15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 32 | S & F of 110 mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joint fixed to walls including clamps for securing pipe and taking down complete all as specified and directed. |
| 33 | S & F of 75 mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joint fixed to walls including clamps for securing pipe and taking down complete all as specified and directed. |
| 34 | S & Fin repair 110 mm bore PVC (SWR) branch piece, single (Single ‘Y’ ) equal or unequal complete all as specified and directed |
| 35 | S & Fin repair110 mm bore PVC (SWR) bend any radius complete all as specified and directed. |
| 36 | S & F in repair75 mm bore PVC (SWR) bend any radius complete all as specified and directed. |
| 37 | S & F 75mm bore PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all specified and as directed. |
| 38 | S&F in repair for Grating doom 100 mm dia of PTMT (minimum weight 25gms) complete all as specified and directed. |
| 39 | S&F in repairs 600mm PVC flush pipe of low or high density 32mm dia including jointing and fixing complete. |
| 40 | Supply and fix in repair vitreous china squatting pan, \"Orissa\" pattern, size 580x440mm, white, integral front or back inlet and foot rest (excluding flushing cistern and flush pipe) including provision of lime concrete bedding and making good to floor complete all as specified and directed. |
| 41 | S&F in repairs Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) completeall as specified and directed. |
| 42 | S&F in repairs plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete. |
| 43 | S & F in repair PVC low level white flushing cistern 10 litre capacity valve less, syphonic action type, complete with inlet, ball valve, float valve, bends, brackets, brass screws, handle, 32 mm dia PVC flush pipe of suitable length and making all connection and making good disturbed surface complete all as specified and directed. |
| 44 | S&FABS BodyHand Faucet with Rubbit cleaning system, 1.25 metre longeasy flex tube in chrome finish & wall hook , fixed in position all as specified and as directed. |
| 45 | S&F in repairs, CP bib tap 15 mm bore, fancy type, screwed down, high pressure, screwed for iron pipe complete all as specified and as directed. |
| 46 | S&F in repair 15mm bore stop cock cast copper alloy, fancy type, chromium plated, screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for union and fixed complete all as specified and directed. . |
| 47 | S&F in repair Stop valve of 15mm dia in PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 90 gms) |
| 48 | S&F in repair bib tap of 15mm dia in PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 90 gms) |
| 49 | S & F of 2nd class hard wood scantling, clean sawn in any position and any description as in unframed work including dismantling of timber scantling 40 Sqcm and over in section, in any position as in unframed or framed workcomplete all as specified and directed. |
| 50 | M&L for 4mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with nails as in ceiling including dismantling wall & ceiling boards of any description including cover fillets complete all as specified and directed. |
| 51 | Dismantling timber scantling infillets, rails, posts, rafters/purlins under 40 sqcm in section complete all as specified and directed. |
| 52 | S&F 2nd class HW plain fillets square rectangular triangular in section, clean sawn secured with nails section area exc. 13 sqcm but n.exc 25 sqcm |
| 53 | S&F 2nd class HW plain fillets square rectangular triangular in section, clean sawn secured with nails sectiona area exc 6 sqcm & n.exc 13 sqcm complete all as specified and directed.. |
| 54 | M&L for preparation of surfaces of wood and wood based materials new or old of any description and girth not otherwise described and treated with two coats of creosite oil complete. |
| 55 | M&L for preparation of surfaces of any description n.exc 10 cm width/girth not otherwise descibed & apply two coats of Synthetic Enamel paint over a coat of pink primer wooden surface complete all as specified and directed. |
| 56 | M&L for preparation of new surfaces and applying two coats ofdistemper on ceiling complete all as specified and directed. |
| 57 | S&F in repair 20 mm dia ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight - 2 1 0 gms complete all as specified and directed. |
| 58 | S & F in repairs to 600mm long PVC flexible Waste pipe to WHB/urinals/Sink complete all as specified and as directed. |
| 59 | Hacking out old broken glass (any thickness, size, quality or description) from wooden frames, glazed with putty or fixed with beads complete all as specified and as directed. |
| 60 | S&F Sheet glass 3 mm thick, ordinary quality and glazing with oil putty in square n.exc 0.5 Sqm in each pane including fixed with wooden beads/glazing pins or spring clips in wooden or metal frames complete all as specified and as directed. |
| 61 | S&F one side frostedglass 3 mm thick, glazing with oil putty in square n.exc 0.5 Sqm in each pane including fixed with wooden beads/glazing pins or spring clips in wooden or metal frames complete all as specified and as directed. |
| 62 | S&F Sheet glass 4.80 mm thick, ordinary quality and glazing with oil putty in square exc 0.5 Sqm in each pane including fixed with wooden beads/glazing pins or spring clips in wooden or metal frames complete all as specified and as directed. |
| 63 | Taking down cement plaster including racking out joints, hacking for key scrubbing down with water etc including removal of rubbish material from site. |
| 64 | M&L for rendering 15 mm thick plaster in CM 1:4 in two coats (10mm and 5mm thick) mixed with water proofing compound with 5mm thick layer on fair faces of brick work or concrete surfaces including finishing the surface even and smooth without using extra cement, complete all as specified and directed. Note: Water proofing compound shall be measured and paid separately. |
| 65 | M&L for 10mm thick plaster in cm (1:6) on fair faces of brick or concrete surfaces including finishing even & smooth without using extra cement. |
| 66 | M&L for 5mm thick plaster in cm (1:3) on fair faces of concrete surfaces of ceiling including finishing even & smooth without using extra cement. |
| 67 | M&L for preparation of new plastered surfaces of walls and applying two coats of oil bound Distemper over one coat primer complete all as specified and directed. |
| 68 | M&L for preparation of new plastered surface and applyingtwo coat of white or tinned with cement base paint over priming coat on exterior wall complete all as specified and directed by Engr-in-Charge. |
| 69 | M&L White wash, three coats on new ceiling surfaces including necessary preparation of surfaces complete all as specified and as directed. |
| 70 | Removal of plant/vegetation/bushes growth etc froom roof or parapet of building including removing of root and making good disturbed surface (n exc 1sqm) with cement mortar 1:3 including mixing only liquid waterproofing compound as per manufacturer instruction complete all as specified and directed. |