| Sl. No. | Item Description |
| 1 | Demolition of PCC/lime concrete (Other than Ground flooors) terracingincluding felt in any description and in any position over roof etc complete all as specified and as directed by the Engineer-in-Charge. |
| 2 | M&L for P.C.C 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in padding over roof finished and laid to required slope complete all as specified and as directed. |
| 3 | M&L for Cutting grooves in brick wall 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and as directed. |
| 4 | M&Lroughening surfaces of old concrete roof by picking ,sweeping clean and washing down with water to remove dust etc and applying a coat of cement slurry @ 3 Kg per Sqm complete all as specified and directed. |
| 5 | M&L for P.C.C 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in coping or roof kerbs on roof chamfered on edge including troweling slightly complete all as specified and as directed. |
| 6 | M&L for 10 mm thick rendering in cement mortar 1:4 on concrete surfaces when concrete is stilgreen finished even and fair including mixing ofwater proofing compound as per manufacturer instructionetc complete all as specified and as directed.Note :- Water proofing compound shall be measured and paid separately. |
| 7 | Supply only integral water proofing compound complete all as specified and as directed. |
| 8 | M&L applying water proofing treatment with the following(a) First coat of bitumen primer conforming to IS-3384 @ 0.3Kg / sqm to be applied on prepared surface till the surface is properly impregnated.(b) after the application of approved bituminous primer the water proofing memberne minimum weight 3kg/sqm and minimum 3mm thick reinforced with polyesterd non woven fabric (weight not less then 160gms/sqm) shall be laid on the primed surface by torch application method as per manufactured instruction including Aluminium paint complete as spd.(c) All joints and change in direction should be curved with cement mortar (1:3) mixed with SBR latex @ 200ml per bag on cement and cured well before laying of membrane. complete all as specified and as directed. |
| 9 | M&L for Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc., and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting exceeding 10 cm but not exceeding 20 cm girth in brick walls complete all as specified and as directed. |
| 10 | Taking up or down existing steel tubing and connections for 15 mm dia bore including cleaning for refixing or removal to store complete all as specified and as directed. |
| 11 | Taking up or down existing steel tubing and connections for 20 mm dia bore including cleaning for refixing or removal to store complete all as specified and as directed. |
| 12 | Supplying, fixing, jointing and testing galvanised iron tubing of size 15 mm dia bore medium grade with all fitting such as bends, elbow, socket, reducer etc and fixed to wall or laid in floor complete all as specified and as directed. |
| 13 | Supplying, fixing, jointing and testing galvanised iron tubing of size 20 mm dia bore medium grade with all fitting such as bends, elbow, socket, reducer etc and fixed to wall or laid in floor complete all as specified and as directed. |
| 14 | Fixing only old steel tubing and connections obtained from taking down against item No 10 &11 herein before in new or old position fixed to wall, ceiling or laid in floor with new fittings for 15mm dia bore |
| 15 | Fixing only old steel tubing and connections obtained from taking down against item No 10 &11 herein before in new or old position fixed to wall, ceiling or laid in floor with new fittings for 20 mm dia bore |
| 16 | S&F 1000 ltr capacity rotational moulded polythene tanks (cylindrical vertical with closed top) hoisted and fixed in position including dismantling existing complete all as specified and as directed. |
| 17 | Fixing only old 1000 ltr capacity rotational moulded polythene tanks (cylindrical vertical with closed top) hoisted and fixed in position including dismantling existing complete all as specified and as directed. |
| 18 | S&F 20mm bore ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minium weight 210 gms ), complete all as specified and directed |
| 19 | S & F in repair 20mm dia Gun metal gate valve with iron wheel head, screwed both ends for iron pipe complete all as specified and as directed. |
| 20 | Demolition ofBrickwork of stone/boulder masonry, build in lime mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articlesl etc complete all as specified and as directed. |
| 21 | M&L brick work with fly ash bricks (FASB) conferming to IS 12894, of strength M-10 straight or curved on plan exc 6m mean radious built cement mortar 1:6 complete (on parapet wall) all as specified and as directed. |
| 22 | M& L, Brickwork, with subclass ‘B’bricks old size straight or curved on plan exc 6 M radiusbuilt in CM 1:6 but except Bricks etc complete all as specified and directed. |
| 23 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises and complete all as specified and as directed. |
| 24 | M&L, for PCC 1:2:4 type B-0 using 12.5mm gradesd stone agg as in levelling course of floors of 25 mm thick complete all as specified and directed. |
| 25 | M&L for screed bed or bedding layer of mortar 15 mm thick in cement mortar 1: 6 to receive tiles etc finished rough complete all as specified and directed. |
| 26 | M&L for Vitrified ceramic tiles 8-10mm thick (square/rectangular) polished area of each tile notexceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchto floor etc complete all as specified and directed. |
| 27 | M&L for non skid colouredceramic tiles 7 to 8 mm thick (square / rectengular) area of each tile exceeding 0.11sqm but not exc 0.18 sqm, in floors etc. set and jointed in neat cement slurryand pointed in white or coloured cement to match to floor etc completeall as specified and as directed. |
| 28 | M&L for Rendering 10mm thick in cement mortar 1: 3 on faces of brick work or concrete surfaces, finished rough to receive tiles etc complete all as specified and directed. |
| 29 | M&L for vitrified ceramic tiles 8-10 mm thick (square / rectangular) polishedarea of each tile exceeding 0.18 sqm but not exc 0.36 sqm, in Vertical surfaces such as skirting, dado etc. set and jointed in neat cement slurryand pointed in white or coloured cement to match to floor etcetccompleteall as specified and as directed |
| 30 | M&L for joint free glazed coloured tiles 350x250x7mm/450x350x7mm thick for work on vertical surface, set & jointed in cement slurry and pointed in white or coloured cement to match etc complete all as specified and as directed |
| 31 | S&F forSolid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specifications and drawing complete all as specified and as directed |
| 32 | S&F in repair false ceiling with 6-8 mm thick gypsum board tiles laminated with white PVC film on face side & metalized polyster film (Aluminium foil) on the back side with all four edges sealed with PVC filmof size 600 x 600 mm (595 X 595 mm) fixed with clips & screws including anodised aluminium snap grid frame work for false ceiling of Tee/Angle of weight not less than 300 gm per RM with slot for fixing including necessary suspender of flat iron or 4 mm dia bars of required length fixed in purlin of roof not exceeding 1.20 m both ways including all accessories required for suspending ceiling work and gypsum board complete all as specified and as directed by the Engineer-in-Charge. |
| 33 | M&L for 18-20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over 15 mm thick in CM(1:6) etc complete all as specified and directed. |
| 34 | S&F in repairs Vitreous china wash down water closet pan(padestal pattern), white(EWC) including plastic seat of same colour of Wc, closed pattern with flat bottom, and cover mild steel chromium plated hinging device complete all as specified and directed |
| 35 | S & F in repair 10 ltrs capacity PVC low level flushing cistern sleek plus single flush of colour star white Make :- Hindwarwith inlet, float valve and handle with 32 mm dia PVC pipe 600 mm long complete all as specified and as directed. |
| 36 | S & F in repairVitreous ChinaTable top Wash hand basin any coloursize 510 x 400 x135 mm size includingwaste pipe complete all as specified and directed |
| 37 | Suppy and fixing for 900mmx600mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed |
| 38 | Supply and fixing CP corner glass shelf with bracket fixed with screws complete all as specified and as directed by Engineer-in-Charge. |
| 39 | S&F CP Brass soap dish fixed to wall with cp brass screws etc complete all as specified and as directed by the Engineer-in-Charge. |
| 40 | S&F in repair PVC connections 15mm size with PTMT nuts of length 450mm etc complete all as specified and as directed. |
| 41 | S&F brass CP mixer 15mm dia bore mixing hot & cold water for wall screwed down for iron pipe and fixedcomplete all as specified and as directed. |
| 42 | S&F in repair 15 mm fancy type chromium plated stop valves/angle valve, screwed down high pressure,with crutch or butterfly handle scresed both ends for iron pipe or for unions and fixed complete all as specified and as directed. |
| 43 | S&F 15mm bore cast copper alloy chromium plated two way angle cock with flangecomplete all as specified and as directed. |
| 44 | S&F in repair 15mm bore fancy type chromium plated bib cock long body with flangeetc complete all as specified and as directed. |
| 45 | S&F brass CP mixer 15mm dia bore mixing hot & cold water for wash hand basin screwed down for iron pipe and fixedall as directed. |
| 46 | S&F in repair concealed stop cock fancy type CP cast copper alloy screwed down high pressure with crutch or buttor fly handle screwed both ends for iron pipe or for unions and fixed 15mm bore complete all as specified and directed. |
| 47 | S&F brass chromium plated health faucetfor EWC screwed down to GI tubing/fittings 15mm dia incl 1200mm long stainless steel connection complete all as specified and directed. |
| 48 | S&F in repair PVC floor trap/Nahani trap outlet dia 75mm with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified and directed . |
| 49 | S&F stainless steeltowel rack fixed to wall with CP brass screws complete all as specified and as directed. |
| 50 | S&F in repair 125 mm Brass chromium plated shower rose with or without swivel joints, any size, including fixing of steel pipe or union and fixed all as directed |
| 51 | S&F in repairchromium plate curtain rod withbrackets and knobs at both end complete all as specified and directed |
| 52 | Taking down chowkhat or frames with shutters (without taking off shutters from the frame) not exe 1.5 Sqm each etc complete all as specified and as directed |
| 53 | Taking down chowkhat or frames with shutters (without taking off shutters from the frame) exe 1.5 Sqm but not exc 4 Sqm each etc complete all as specified and as directed. |
| 54 | S&F solid PVC frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with M.S. square tube, S&F in opening as per specification & drawing etc complete all as specified and as directed |
| 55 | S&F factory made solid panel PVC door shutter 30mm thick (style) constiting of frame made out of MS tubes for top & bottom rails, MS frame shall be covered with heat moulded plain colour PVC \"C\" channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and palin colour PVC sheet for top rail lock rail & botom rail on either side and as gap insert for top rail bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/selaed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement S&F in the frame at site as per specification & drawing etc complete all as specified and as directed. |
| 56 | S&F100 mmbutt hinges,extruded aluminium alloy with galvanised mild steel hinge pin, anodised type C-1 and fixed etc complete and as directed. |
| 57 | S&F, aluminum handles cast type anodized 125 mm size etc complete all as specified and as directed |
| 58 | S&F, aluminum anodized barrel tower bolts of extruded section 150 mm long etc complete all as specified and as directed |
| 59 | M&L for Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified |
| 60 | M&L foraluminium powder coated glazed door shutter( Single leaf ) fabricated out of approved powder coated aluminium sections , shutter havingbottom rail of section size 114.50 mm x 44.50 mm x2.0 mm thick section, middle and top rail of section 84.50 mm x 44.50 x 2 mm thick section andstyles of section size84.50 mm x 44.50 mm x 2 mm thickand S & F 5.5 mm thick tinted glass in panel of shutter fixed with glazing clips , rubber gasket and powder coated aluminium snap beading so as to make air tight and including S & F powder coated butt hinges type C-1,100 mm size 3 nos per shutter , powder coated aluminium handle of 150mm size 2 Nos (One on each side of shutter) , powder coated aluminium tower bolt of size 200 mm ( 2 Nos ) per shutter ,mortise lock , brass body ,6 levers ( 1 No) with duplicate keys, aluminium (extruded section) hydraulic door closer regulated designation No-3 Universal type ( 1 No) & Floor door stopper ( 140 mm ) overall ,aluminium body 1 No on each shtteretc complete all as specified and as directed. Note: (i) Shutter ( Glazed ) shall be fixed on frame of required size and shall be measured seperately (iii) Cost of all fittings & fixture shall deemed to be included in unit quoted rate by the tenderer . Note : The minimum thickness of powder coating shall be 50 Micron . |
| 61 | S & F powder coated aluminium window/ventilator colour as approved by GE with double hung shutter (both gauged and glazed ) including alumunium grillof size 50x50mm with 6mm dia bar fixed with GI wire mesh cloth 0.46mm dia of wire and 1.18mm aperature , both fixed onaluminium frame 126 mm x 50 mm x1.5 mm thick, shutter with bottom rail, middle rail, top rail and styles of size 44.45 mm x 47.62 mm x 1.2 mm thick as per IS 737-1986 and glazed with tinted glass (Modi guard ) 5 mm thick as per standard practices and with alumunium powed coated handle & tower bolt arrangements incl taking down existing window etc complete all asspecifiedand as directed. |
| 62 | Supply only5.5 mm thick sheet glass SELECTED QUALITYTINTED complete all asspecifiedand as directed. |
| 63 | M&L chequered tiles (Cement) 30cm X 30cm x 25mm set and jointed and pointedin neat cement slurry infloor with grey cement and pigment over & including 20mm thick screed bed in CM (1:6) Complete all as specified and directed. |
| 64 | M&L for Excavating in trenches , notexc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pipelines, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in Hard/dense soil complete all as specified and directed |
| 65 | Demolition and breaking drain pipe (salt glazed stoneware) set in cement mortar including packing under and haunching against side of pipe for 150 mm Internal dia of pipe complete all as specified and directed |
| 66 | M&L for Concrete bed to drain pipes 150mm including packing under, and haunching againstthe sides of pipes after they are laid and tested; in cement concrete 1:3:6 type C-2 complete all as specified and directed |
| 67 | M&L Salt glazed stone ware (SGSW) grade \"A\" pipe 150mm bore laid and jointed on concrete bed complete including testing all as complete all as specified and directed |
| 68 | M&L brick work with sub class \"B\" bricks straight or curved on plan exc 6m mean radious and built in cm 1:4 complete all as specified and directed. |
| 69 | M & L for brick work with sub-class `B\" bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar (1:4)but except bricks (Brick shall be obtained from demolition. Unit rate for cleaning of old bricks shall be included in this item). complete all as specified and directed. |
| 70 | M&L Cement Concrete 1:2:4 type B1 (using 20mm graded stone agg) as in benching coping and including necessary form work weathering slightly rounded or chemfered angles and throating complete all as specified and directed. |
| 71 | M & L for cement concrete type C2 (1:3:6) (using 40 mm graded stone aggregate) in surface channels, drains and manhole foundation etc.complete all as specified and directed. |
| 72 | M&L for rendering 15mm thick on fair faces of wall even and smooth finish without using extra cement onconc/brick surfaces in CM 1:4, complete all as specified and as directed |
| 73 | M & L for preparation of new plastered surface and applying three coat of white wash on ceiling complete all as specified and as directed. |
| 74 | Demolition of Reinforced concrete of any description and in any position not otherwise specifically provide for complete all as specified and directed. |
| 75 | M&L precast Cement Concrete 1:2:4 type B1 (using 20mm graded stone agg) as in cover slabs for man holes etc set in cement mortar 1:6 including necessary form work complete all as specified and directed |
| 76 | M&L for TMT steel bars 6 to 8 mm diacut to length bent to shape, required including cranking benchings spirally hooping for colums hooking ends and binding with and including mild steel wire annealed) not less than 0.9mm dia complete all as specified and directed |
| 77 | Returning filling in excavated approved earth into trenches around pipe etc after laying of pipes and testing complete including watering and well ramming in 25mm layer complete all as specified and directed |
| 78 | Removing surplus soil to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed |
| 79 | Taking down exiting AC/PVC rain water /waste pipe from wall/ floor complete all as specified and directed |
| 80 | S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors 110mm borecomplete all as specified and directed |
| 81 | S & F 75mm dia, PVCpipes, single socketed, in any length with sealant rubber ringjoints fixed to walls/trenches including necessary MS flat Iron clamps of size (40 x 4mm) all as specified and as directed by the Engineer - in - Charge. |
| 82 | S&F PVC (SWR) bends any radius 110mm bore complete all as specified and directed. |
| 83 | S&F PVC (SWR) junction single, (single T) equal or unequal 110mm bore complete all as specified and directed. |
| 84 | S&F PVC (SWR) bends any radius 75mm bore complete all as specified and directed. |
| 85 | S&F PVC (SWR) junction single, (single T) equal or unequal 75 mm bore complete all as specified and directed. |
| 86 | S&F PVC (SWR) vent cowl 110mm bore complete all as specified and directed. |
| 87 | Taking down carefully existing aluminum / copper point wiring (light, fan, socket or power point) complete of any description including fitting such as switches, ceiling roses, pendants, tube light fitting, ceiling fan with regulators, sockets, wooden boards, laminated sheets from sunken boxes, boards, shades light fitting etc and making good the disturbed surfaces of walls, floors, ceiling etc to match with existing surfaces complete all as specified and directed. |
| 88 | Taking down submain wiring of any size any type and in any position metalic/non metallic PVC conduit of wooden batten complete all as specified and directed. |
| 89 | Taking down unserviceable Sheet metal box & MCB DB TPN with MCB\"s of any make/capacity, complete, all as specified and directed by Engr-In-Charge. |
| 90 | M&L for concealed point wiring with PVC insulated and unsheathedelectric cable 1100 volts grade single core FRLSH confirming to IS 694:2010 having multi stranded copper conductor of 1.5 Sqmm nominal cross sectional area (ISI marked with valid CML No) drawn in and including concealed non metallic rigid PVC conduit medium grade( ISI marked with valid CML No)not less than 20 mm diawith all fitting and fixing accessories and1.5 Sqmm FRLSH confirming to IS 14930 (Part-I) 2001, PVC insulated unsheathed multistranded copper conductor cable as continuous earth conductor, connected to common earth dolly by providing suitable lugs with & including pressed steel sunken terminal boxes/modular flush boxfactory made for mounting switch, regulators etc with and including 2.8 mm thick plastic laminated sheet cover (white) ISI marked, fixed with brass screws and cup washers duly painted with two coats of anti corrosive paint/black bituminous paint outside and two coats of aluminium paint insidefor mounting switches. sockets etc complete all as specified and directed for One light point controlled by one switch. |
| 91 | Ditto all as per item no.90 for One Ceiling fan/exhaut point controlled by one switch. |
| 92 | Ditto all as per item no.90 for One 5 pin multipurpose socket out let 5/6 Amps on the same board with other switch. |
| 93 | Ditto all as per item no.90 for One 3 pin/5 pin switch socket outlet, 5 Amps on independent board. |
| 94 | Ditto all as per item no.90 for one bell/buzzer point controlled by one switch |
| 95 | Description all as per item No 90 here in before but point wiring with 2.5 sqmm FRLSH H confirming to IS 694:2010, multistrand copper conductor cable for one six pin socket outlet 15 Amps controlled by one switch on independent board and 2.5 sqmm FRLSH PVC insulated multi strand copper conductor cable as continous earth wire. |
| 96 | S&F Modular switch 1 way 6A,1 module complete all as specified and directed. |
| 97 | S&F Socket, 6A - 2/3 pin combined 2 module,complete all as specified and directed. |
| 98 | S&F Modular switch 1 way 16A,1 module 15 Amp complete all as specified and directed. |
| 99 | S&F Socket 6A/16A - 6 pin combined 2 module complete all as specified and directed. |
| 100 | S&F ceiling rose surface bakelite 63.5 mm dia three terminal complete all as specified and directed. |
| 101 | S&F Fan step regulator, 120W - 2 module 240 volts, AC 50Hz complete all as specified and directed. |
| 102 | S&FLamp holder with metal ring, PVC/Polycarbonate type with back plate suitable for batten fittings ISI Marked complete all as specified and directed |
| 103 | Supply and fixDecorative wall light fixture made up of Polycarbonate and including connecting with 3 Core twisted flexible copper conductor cable of suitable size from celling rose complete all as specified and directed by Engineer-in-Charge. |
| 104 | S&F modular socket 20 amp with MCB 20 Amp \"C\" type all specified and complete all as specified and directed |
| 105 | S & F 9W/10W LED retrofit lamp B-22 holder base with polycorbonate body and aluminium heat sink complete all as specified as directed. |
| 106 | S&F LED T/L fitting completre with basic all porpose surface and wall mountedled batten with aluminium housing & intergrated elecotronic driver 10 watt capacity 2 feet long and incl connection from ceiling rose complete all as specified and as directed. |
| 107 | S&F electric bell, AC 230 volt, single pole, ding dong type including bell pushcomplete all as specified and directed |
| 108 | Supply and fixing in repair 22 W LED 6000k Decorative ultra slim linear LED fitting fixture with extruded polycarbonate ,environmental friendly ,energy efficentinterated driver and 28watts lamp fitted including wiring upto and terminal into ceiling rose complete all as specified and directed by Engr-in- Charge. |
| 109 | Supply and fix LED 35W street light fitting,5700 K energy saving & environmental friendly long life versatile pressure die cast aluminiumIP 66.road way luminare with high power LEDs as light source and electronic driver suitable for pole dia 35 mm including 35 mm dia light grade tube bracket ,bend to shape 1.80 mtrlength with two nos of clamps of size 50mm x 6mm with nuts and bolts,washers etcincluding connection with 1.5sqmm threesinglecorePVC insulated and PVC sheathed cable stranded copper cable upto ceiling rose and fixing on walls/pole complete all as specified and directed. |
| 110 | M&L for sub main wiringwith two single core PVC insulated unsheathed FRLSH confirming to IS 694:2010, multi stranded copper conductor (ISI marked with valid CML No), cable 1100 Volt grade, 4 sqmm size drawn in and includingnon metallic rigid PVC concealed conduit medium grade (ISI marked with valid CML No) not less than 25 mm dia with all fitting & fixing accessories including one run single core PVC insulated unsheathed 4 Sqmm FRLSH confirming to IS 14930 (Part-I) 2001, copper conductor (ISI marked with valid CML No) colour code as a earth continuity and connected upto DB complete all as specified and directed.(NOTE: (i) Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit and the quoted rates shall be deemed to be inclusive for cutting chasesin wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface with putty to match with the existing surface. |
| 111 | M&L, sub main wiringwith two single core PVC insulated unsheathed FRLSH confirming to IS 694:2010, multi stranded copper conductor (ISI marked with valid CML No), cable 1100 Volt grade, 6 sqmm size drawn in and includingnon metallic rigid PVC concealed conduit medium grade (ISI marked with valid CML No) not less than 25 mm dia with all fitting & fixing accessories including one run single core PVC insulated unsheathed 6 Sqmm FRLSH confirming to IS 14930 (Part-I) 2001, copper conductor (ISI marked with valid CML No) colour code as a earth continuity and connected upto DB complete all as specified and directed.(NOTE: (i) Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit and the quoted rates shall be deemed to be inclusive for cutting chasesin wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface with putty to match with the existing surface. |
| 112 | S&F TPN DB-DPX 100 MCCB DBs 4 way double door with provision for DPX 100 MCCB andas incomer CONCEALED ON WALLand SP/TP MCBs as out going no of modules DPX 100, Complete all as specified and as directed. Make:- ABB / Havells / HPL / Standard. |
| 113 | Supply and fix MCCB having breaking capacity of of 16 KA 415V, 4 pole having rating capacity of 100 Amp 100% ICU complete all as specified and as directed. |
| 114 | S&F MCB DB, sheet metal enclosures double door SPN 8 way with bus bar 240 volts 2 in 1 shutter type (METAL DOOR)type with blanking plates where required and IP 43 degree protection complete all as specified and directed.. |
| 115 | S&F, MCB SPN 40-63 Amps, 240 volts \"C\" series 10 KA ,including connection with suitable size copper lugs complete all as specified and directed.. |
| 116 | S&F, MCB SP 240 volts, 6to 40 Amps, \"C\" series 10 KA including connection with suitable size copper lugs.complete all as specified and directed. |
| 117 | S&F for modular White cover plate with frame but 2/3/4 module including fixing , modular switchs , modular socket ,modulare regulator complete all as specified and directed by engr-in-charge. |
| 118 | S&F for modular White cover plate with frame but 6/8/12 module. including fixing , modular switchs , modular socket ,modulare regulator complete all as specified and directed by engr-in-charge. |
| 119 | Supply and laying or fixing or passing through HDPE pipe, 1100 volts grade heavy duty cable with XLPE insulated stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel or strip and overall PVC sheathed, 25 sq mm 4 core ISI Marked as per IS 7098(Part 1) including connecting on LT OH line / LT panel /DB with suitable lugs, glands, binding wire etc complete all as specified and directed. |
| 120 | Excavationin trenches in any type of soil not exe 1.5 mtrs wideand not exe 1.5 mtr in depth for laying of pipe/cables etc and getting out incl forming bottom surface to the required level/slope etc complete all as specified and directed . |
| 121 | Returning fitting in soft/loose soil, including spreading levelling watering and well ramming in layers n.exc 25 cm complete all as and directed |
| 122 | Removing excavated soils to a distance n.exc. 50 mtrs and depsiting where directed at a level n.exc. 1.5 above the starting point complee all as specified and directed |
| 123 | Material and labour for Double wall corrugated HDPE pipe, ISI marked of outer dia 50mm, inner dia 38mm with smooth internal and profiled external surface, non-pressure type, laid in trenches/floors/duct or fixed on walls /pole including all connections, accessories like socket, couplers, bends, etcfor protection of LT cable XLPE grade 1100 volts complete all as specified and directed by Engineer-in-Charge. |
| 124 | M&L pipe galvanised iron of size 50 mm dia, light grade ISI marked, complete with fittings laid in trenches/ fixed with poles etc as protection to cables complete as directed by Engineer in Charge |
| 125 | M&L for earthing completewith galvanisedsteelearth plateelectrode of size 600 mm x 600 mm x 6 mm thickweithing not less than 17.5 Kg buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth lead wire 4.00 mm dia by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore( light grade)and watering pipe 20 mm bore GI pipe(light grade) andchamber of pcc 1:4:8 type D2 using 40 mm graded stone aggregate and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg.50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 3 of SSR PT 1, 2009 with charcoal dust and saltcomplete and earth leadconnected to earthing test point (up to main switches, DBs) completeall as specified &testing on completion. NOTE:-(I)item includes the cost of 7.5 mtr length GI pipe for protection for GI earth wire. (ii) item rates includes the cost of 7.5 mtr earth lead GI earth wire. (iii)PCC pit shall be provided at least 500mm away from the pit and not on the earth pit itself and the extra costof additional length of watering pipe,bends,elbow etc shall be deemed included in the unit rate. |
| 126 | Supply , installing, testing and commissioning factory made and tested, CPRI approvedLTfeeder pillar, outdoortypefloor mounted,suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber duly insulated . The panel shall be dust and vermin proof, IP 65 class protection and made of3.15mm CRCA MS sheet and LT panel shall be as per IS/IEC 61439-I: 2011 &IS/IEC 61439-2 : 2011 and mounted on angular frame work of 50x50x5mm thick angle iron base frame work,minimum 60 cm high and fixed with PCC 1:4:8 type D2 (using 40mm graded stone aggregate) in foundation for fixing panels, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside,both side openingtype, with aprons for cable entry,with double door shutter and locking arrangement and consisting of the followingall as specified including taking down old feeder pillar and taking out LT cables from loop for connecting in new panel and necessary excavation etc and consisting of the following:- Note:- (a)Panel drawings and make of MCCB will be submitted by contractor for approved by GE before orders the panel. (b)The holes/ aprons of cable entry/ exit will be closed with suitable size of glands. |
| 127 | Item No 126 contd...(a)Aluminumbus barfour strips600 Amps ,415 volts, fixed on epoxy insulated on panel fixed horizontally, duly insulatedwithheat shrinkable sleeves in colour code - 01 Set. Incoming(b)MCCB,04 Pole, 400 Amps with ultimate breaking capacity 36 KA at 415 volts, adjustable type withthermal and magnetic settings conforming to IEC 60947 Part-I/IS-13947 Part-I- 01 No (Ics=Icu=100%)Outgoing(c)MCCB,04 Pole, 200 Amps with ultimate breaking capacity 36 KA at 415 volts with fixed thermal settings conforming to IEC 60947 Part-I/IS-13947 Part-I- 02 No (Ics=Icu=100%)(d) MCCB,04 Pole, 160 Amps with ultimate breaking capacity 25 KA at 415 volts with fixed thermal settings conforming to IEC 60947 Part-I/IS-13947 Part-I - 04 Nos (Ics=Icu=100%)(e) MCCB,04 Pole, 63 Amps with ultimate breaking capacity 16 KA at 415 volts with fixed thermal settings conforming to IEC 60947 Part-I/IS-13947 Part-I- 01 No (Ics=Icu=100%)(f) Digital typevoltmeter0-500 Volt with selector switch with MCBs -1 Set(g) Digital typeAmmeter0-500 Volt with selector switch with MCBs -1 Set(h) Indication lamps R,Y,B LED type with 3 Nos of 2A HRC fuses -1 set: |
| 128 | Item No 126 contd...(i) Internal wiring with suitable size of PVC insulated stranded copper conductor cable duly crimped with copper lugs & ferruled and aluminumstrips for MCCB\"s.Note: Panel drawing and make of MCCB and connected accessories will be submitted by the contractor for approval of Accepting officer before ordering the panel. Make of LT panel :- M/s Mclayers Bhopal/M/s shalabh(india) Ltd/ M/suniversal switchgear Ltd and Make of MCCB :- L&T/ABB/Havells/Schneider/Legrand Note:-(i) CA No.,Contractor name, item of CA No. to be mentioned on the panel.(ii)Suitable Cable glands for incoming cables and outgoing cable to be provided in the panel by the contractors. Cost of provisioning of cable glands deemed to be included in qouted rate. |
| 129 | Supply , installing, testing and commissioning factory made and tested, CPRI approvedLTfeeder pillar, outdoortypefloor mounted,suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber duly insulated . The panel shall be dust and vermin proof, IP 65 class protection and made of3.15mm CRCA MS sheet and LT panel shall be as per IS/IEC 61439-I: 2011 &IS/IEC 61439-2 : 2011 and mounted on angular frame work of 50x50x5mm thick angle iron base frame work,minimum 60 cm high and fixed with PCC 1:4:8 type D2 (using 40mm graded stone aggregate) in foundation for fixing panels, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside,both side openingtype, with aprons for cable entry,with double door shutter and locking arrangement and consisting of the followingall as specified including taking down old feeder pillar and taking out LT cables from loop for connecting in new panel and necessary excavation etc and consisting of the following:- Note:- (a)Panel drawings and make of MCCB will be submitted by contractor for approved by GE before orders the panel. (b)The holes/ aprons of cable entry/ exit will be closed with suitable size of glands. |
| 130 | Item No 129 contd...(a)Aluminumbus barfour strips500 Amps ,415 volts, fixed on epoxy insulated on panel fixed horizontally, duly insulatedwithheat shrinkable sleeves in colour code - 01 Set. Incoming(b)MCCB,04 Pole, 315 Amps with ultimate breaking capacity 36 KA at 415 volts, adjustable type withthermal and magnetic settings conforming to IEC 60947 Part-I/IS-13947 Part-I- 01 No (Ics=Icu=100%)Outgoing(c)MCCB,04 Pole, 160 Amps with ultimate breaking capacity 36 KA at 415 volts with fixed thermal settings conforming to IEC 60947 Part-I/IS-13947 Part-I- 02 No (Ics=Icu=100%)(d) MCCB,04 Pole, 100 Amps with ultimate breaking capacity 16 KA at 415 volts with fixed thermal settings conforming to IEC 60947 Part-I/IS-13947 Part-I - 01 Nos (Ics=Icu=100%)(e) MCCB,04 Pole, 63 Amps with ultimate breaking capacity 16 KA at 415 volts with fixed thermal settings conforming to IEC 60947 Part-I/IS-13947 Part-I- 01 No (Ics=Icu=100%)(f)Digital typevoltmeter0-500 Volt with selector switch with MCBs -1 Set(g) Digital typeAmmeter0-500 Volt with selector switch with MCBs -1 Set(h) Indication lamps R,Y,B LED type with 3 Nos of 2A HRC fuses -1 set: |
| 131 | Item No 129 contd...i) Internal wiring with suitable size of PVC insulated stranded copper conductor cable duly crimped with copper lugs & ferruled and aluminumstrips for MCCB\"s.Note: Panel drawing and make of MCCB and connected accessories will be submitted by the contractor for approval of Accepting officer before ordering the panel. Make of LT panel :- M/s Mclayers Bhopal/M/s shalabh(india) Ltd/ M/suniversal switchgear Ltd and Make of MCCB :- L&T/ABB/Havells/Schneider/LegrandNote:-(i) CA No.,Contractor name, item of CA No. to be mentioned on the panel.(ii)Suitable Cable glands for incoming cables and outgoing cable to be provided in the panel by the contractors. Cost of provisioning of cable glands deemed to be included in qouted rate. |
| 132 | Supply , installing, testing and commissioning factory made and tested, CPRI approvedLTfeeder pillar, outdoortypefloor mounted,suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber duly insulated . The panel shall be dust and vermin proof, IP 65 class protection and made of3.15mm CRCA MS sheet and LT panel shall be as per IS/IEC 61439-I: 2011 &IS/IEC 61439-2 : 2011 and mounted on angular frame work of 50x50x5mm thick angle iron base frame work,minimum 60 cm high and fixed with PCC 1:4:8 type D2 (using 40mm graded stone aggregate) in foundation for fixing panels, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside,both side openingtype, with aprons for cable entry,with double door shutter and locking arrangement and consisting of the followingall as specified including taking down old feeder pillar and taking out LT cables from loop for connecting in new panel and necessary excavation etc and consisting of the following:- Note:- (a)Panel drawings and make of MCCB will be submitted by contractor for approved by GE before orders the panel. (b)The holes/ aprons of cable entry/ exit will be closed with suitable size of glands. |
| 133 | Item No 132 contd..(a)Aluminumbus barfour strips 400 Amps ,415 volts, fixed on epoxy insulated on panel fixed horizontally, duly insulatedwithheat shrinkable sleeves in colour code - 01 Set. Incoming(b)MCCB,04 Pole, 250 Amps with ultimate breaking capacity 36 KA at 415 volts, adjustable type withthermal and magnetic settings conforming to IEC 60947 Part-I/IS-13947 Part-I- 01 No (Ics=Icu=100%)Outgoing(c)MCCB,04 Pole, 125 Amps with ultimate breaking capacity 25 KA at 415 volts with fixed thermal settings conforming to IEC 60947 Part-I/IS-13947 Part-I- 02 No (Ics=Icu=100%)(d) MCCB,04 Pole, 63 Amps with ultimate breaking capacity 16 KA at 415 volts with fixed thermal settings conforming to IEC 60947 Part-I/IS-13947 Part-I - 02 Nos (Ics=Icu=100%)(e) MCCB,04 Pole, 40 Amps with ultimate breaking capacity 16 KA at 415 volts with fixed thermalsettings conforming to IEC 60947 Part-I/IS-13947 Part-I- 01 No (Ics=Icu=100%)(f)Digital typevoltmeter0-500 Volt with selector switch with MCBs -1 Set(g) Digital typeAmmeter0-500 Volt with selector switch with MCBs -1 Set(h) Indication lamps R,Y,B LED type with 3 Nos of 2A HRC fuses -1 set: |
| 134 | Item No 132 contd...i) Internal wiring with suitable size of PVC insulated stranded copper conductor cable duly crimped with copper lugs & ferruled and aluminumstrips for MCCB\"s.Note: Panel drawing and make of MCCB and connected accessories will be submitted by the contractor for approval of Accepting officer before ordering the panel. Make of LT panel :- M/s Mclayers Bhopal/M/s shalabh(india) Ltd/ M/suniversal switchgear Ltd and Make of MCCB :- L&T/ABB/Havells/Schneider/LegrandNote:-(i) CA No.,Contractor name, item of CA No. to be mentioned on the panel.(ii)Suitable Cable glands for incoming cables and outgoing cable to be provided in the panel by the contractors. Cost of provisioning of cable glands deemed to be included in qouted rate. |
| 135 | M & L for earthingcomplete with galvanized steel earth plate electrode600 x 600 x 6 mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level)with top edge of the plate not less than 1.5 mtr below normal GL and connected to earth plate . Earth plate surrounded by 15 cm thick packed layers of charcoal dust and common saltupto 1.5 meter depth all around the earth plate and connected to galvanised earth strip 32x6mm by means of bolts, nuts, check nuts and washers of galvd iron or steel surronded by charcoal of coke and saltand protected by galvanized iron or steel pipe light grade 40 mm bore and water pipe 20mm bore GI medium grade with funnel and wire mesh, including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electrical plate No 5 of MES schedule Pt I of2009 and also including making test point for testing of earthingmade out ofgun metal or phosphorous bronge size 75x75x25 mm complete . Note : 1. RCC pit cover shall be pre-cast of RCC (1:2:4) type B-I , 80mm thick reinforced with XPM weighting not less than 4 KG/sqmmin lieu of CI cover.2. Charcoal dust and commonsaltupto 1.5 meter depth shall be filled in layers of 15 centimeters all around the earth plate inside earth pit .On testing after completion of earthing if desired earth resistance is not achieved , the earthing will be redone at no extra cost to obtain the desired earth values less than 2 ohms.3. The cost of GI earth lead and GI pipe of 7.50m lenth for protection of GI wire and excavationwork fpr pit shall deemed to be included in this item. |
| 136 | S&F for replacement & testing commissioning of outdoor type bus bar panel weather proofMS cubical panelboard made of3.15 mm CRCA MS sheet outdoor type of size 110 cm x 80 cm x 40 cm, 4 Nos of aluminium bus bar of 400 Amp capacity with MCCB 4 pole of Capacity 250 Amp 25 KA (Ics =Icu=100%) including one coat of redoxide and two coat of enamel paint powder coated, mounted onangular frame work of 50x50x5mm thick angle iron base frame, minimum 60 cm hightand fixed with PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) in foundation for fixing panels,powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside and PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) in foundation for fixing panels & aluminium busbar chanel insulated with colour coated heat shrinkable sleaves and mounted on DMC/Epoxy insulator all as specified & directed. Make:- M/s Mclayers Bhopal/M/s shalabh(india) Ltd/ M/suniversal switchgear Ltd and Make of MCCB :- L&T/ABB/Havells/Schneider/LegrandNote:-(i) CA No.,Contractor name, item of CA No. to be mentioned on the panel.(ii)Suitable Cable glands for incoming cables and outgoing cable to be provided in the panel by the contractors. Cost of provisioning of cable glands deemed to be included in qouted rate. |
| 137 | S&F for replacement & testing commissioning of outdoor type bus bar panel weather proofMS cubical panelboard made of3.15 mm CRCA MS sheet outdoor type of size 110 cm x 80 cm x 40 cm, 4 Nos of aluminium bus bar of 300 Amp capacity with MCCB 4 pole of Capacity 200 Amp 25 KA (Ics =Icu=100%) including one coat of red oxide and two coat of enamel paint powder coated, mounted onangular frame work of 50x50x5mm thick angle iron base frame, minimum 60 cm hightand fixed with PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) in foundation for fixing panels,powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside and PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) in foundation for fixing panels & aluminium busbar chanel insulated with colour coated heat shrinkable sleaves and mounted on DMC/Epoxy insulator all as specified & directed. Make:- M/s Mclayers Bhopal/M/s shalabh(india) Ltd/ M/suniversal switchgear Ltd and Make of MCCB :- L&T/ABB/Havells/Schneider/LegrandNote:-(i) CA No.,Contractor name, item of CA No. to be mentioned on the panel.(ii)Suitable Cable glands for incoming cables and outgoing cable to be provided in the panel by the contractors. Cost of provisioning of cable glands deemed to be included in qouted rate. |
| 138 | S&F for replacement & testing commissioning of outdoor type bus bar panel weather proofMS cubical panelboard made of3.15 mm CRCA MS sheet outdoor type of size 110 cm x 80 cm x 40 cm, 4 Nos of aluminium bus bar of 250 Amp capacity with MCCB 4 pole of Capacity 160 Amp 25 KA (Ics =Icu=100%) including one coat of red oxide and two coat of enamel paint powder coated, mounted onangular frame work of 50x50x5mm thick angle iron base frame, minimum 60 cm hightand fixed with PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) in foundation for fixing panels,powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside and PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) in foundation for fixing panels & aluminium busbar chanel insulated with colour coated heat shrinkable sleaves and mounted on DMC/Epoxy insulator all as specified & directed. Make:- M/s Mclayers Bhopal/M/s shalabh(india) Ltd/ M/suniversal switchgear Ltd and Make of MCCB :- L&T/ABB/Havells/Schneider/LegrandNote:-(i) CA No, Contractor name, item of CA No. to be mentioned on the panel.(ii)Suitable Cable glands for incoming cables and outgoing cable to be provided in the panel by the contractors. Cost of provisioning of cable glands deemed to be included in qouted rate. |