}

Supply & Installation Of Different Electrical Accessories, Lighting Arrangement And Allied Works At Different. (Water / Pipe) Testing Laboratories Under P.H.E. Dte., Dist.- Purba Bardhaman., purba-West Bengal

Public Health Engineering Department has published Supply & Installation Of Different Electrical Accessories, Lighting Arrangement And Allied Works At Different. (Water / Pipe) Testing Laboratories Under P.H.E. Dte., Dist.- Purba Bardhaman.. Submission Date for this Tender is 02-06-2025. Electrical Products Tenders in purba West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

49286561
Supply & Installation Of Different Electrical Accessories, Lighting Arrangement And Allied Works At Different. (Water / Pipe) Testing Laboratories Under P.H.E. Dte., Dist.- Purba Bardhaman.
Tender
Indian
West Bengal
Purba
02-06-2025

Tender Documents

Tender Details

Supply & Installation of different electrical accessories, Lighting arrangement and allied works at Different. (Water / Pipe) Testing Laboratories under P.H.E. Dte., Dist.- Purba Bardhaman.- 1 List of following Six no.(6) water testing Laboratories &One no.(1) Pipe testing Laboratories:-1)District Laboratories2)Pipe testing Laboratories3)Sehera SDWTL4)Sankari SDWTL5)Satgachia SDWTL6)Barshul SDWTL7)Saktigarh SDWTL 2 Distribution wiring in 1.1KV grade 2 x 22/0.3 (1.5 sqmm) single core stranded FRPVCinsulated & unsheathedcopper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit FR (Precision make) [for ceiling portion only] andin 19 mm bore, 3 mm thick polythen pipe[for horizontal & vertical run embedded in wall],with 1 x 22/0.3 (1.5 sqmm) single core stranded FRPVCinsulated & unsheathedcopper wire for ECC, to light/fan/call bell points with Modulartype switch (Brand approved by EIC)fixed on Modular GI switch board complete with 2 no. suitable size Ph & N copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish.[Only PVC Rigid conduit on ceiling and remaining portion concealed.] 3 Average run 6 mtr 4 Supply & delivery of thefollowing Items. 5 15 amp single phase socket 240V,50 Hz.make-Havells /approved make. 6 15 Amp Piano key type Switch 240V,50 Hz.make-Havells /approved make. 7 16A MCB DP C Curve (White)240V,50 Hz.make-Havells/approved make 8 32 amp modular double pole MCB ,C curve 240V,50 Hz.make-Havells/approved make 9 4 long 20 watt LED tube light set white colour (Make -Philips/ Havells) 10 32 amp Industrial plug & Socket.( Make-Havells) 11 32 amp modular four pole MCB ,C curve 415V,50 Hz.make-Schneider/Havells/approved make. 12 32 amp modular one way switch 240V,50 Hz.make-Havells/approved make 13 40 amp modular one way switch 240V,50 Hz.make-Havells/approved make 14 40 amp modular four pole MCB ,C curve 415V,50 Hz.make-Schneider/Havells/approved make. 15 supply of 4 module PVC switch board .(make -Schneider/Approved Make) 16 supply of 6 module PVC switch board .(make -Schneider/Approved Make) 17 supply of 8 module PVC switch board .(make -Schneider/Approved Make) 18 300 mm/ suitable sweep Exhust fan (Make: Approve make of P.H.E. Dte.) 19 Lamp holder 20 14 watt LED lamp (Make- Philips/ Havells) 21 4 sq.mm single core 1.1KV grade PVC & HRFR insulated copper cable.Make-Havells/approved make 22 6 sq.mm single core 1.1KV grade PVC & HRFR insulated copper cable.Make-Havells/approved make 23 10 sq.mm single core 1.1KV grade PVC & HRFR insulated copper cable.Make-Havells/approved make 24 Supply Microtek Line Interactive UPS LEGEND 650 UPSMicrotek Line Interactive UPS LEGEND 650 UPS.(Make: Approve make of P.H.E. Dte.) 25 Installtion and fitting fixing of above supplied items (sl-03) including supply of cable gland,socket and power line connection modification in existing electrical system as required to complete the job as per direction and upto the entire satisfaction of EIC. 26 Supply and fitting fixing of Ceiling fan (Make: Usha /C.G / Havells/ approvedmake) 1200mm. sweep complete with rubber bush, nut, bolt etc. including supply and fixing 2×1/1.4 PVC copper wire for down rod with making necessary connection complete. 27 Supply and fitting fixing of 45 watt. LED light fixture set[Make: Philips (Type- BRP)/ Havells/ PHED approved make] with 40 mm dia x 2.5 mtr. long G.I pipe bracket fixed on the roof of the pump house with M.S clamp properly grouting including making power connection with supply & drawing 2.5 sq. mm FR grade flexible copper wire through PVC casing/conduit with drawing earth conductor (1.0 sq mm copper flexible wire), S&F of 15 amp switch with pvc board including electrical connection & testing complete as per direction of EIC. 28 Makingearthing arrangement 29 Earthing with 50 mm dia Gl pipe 3.64 mm thick x 3.04 Mts.long and 1 x4 SWG Gl (Hot Dip) wire (4 Mts. long), 13 mm dia x80 mm long Gl bolts, double nuts, double washers incl. S & F 15mm dla Gl pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above groundlevel driven to an average depth of 3.65 Mts. below the ground level as below: By lSl-Medium Gl pipe 30 Extra for providing masonery enclosure on the top of theearthelectrode of overall size 86.36 cm x 86.36 cm x 46 cm deep(below Ground level) complete with cemented brick work(1:6)of 25 cm width duly plastered with cement morter (inside) Cl hinged inspection cover of size 36.56 cm x 35.56 cm withlocking arrangement, Gl reducer including drilling of 46 nos.12 mm dia holes on the Gl pipe 31 Extra for treatment of soil by using salt & charcoal or cokeforplate electrode. 32 Connecting the equipments body to earth busbar including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with Gl saddles as required and connection to equipments incl.drilling holes, with bolts, nuts, washers etc. 33 Supplying and fitting-fixing of earth busbar of galvanized (Hot dip) fVS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with Gl bolt,nuts,washers,spacing isolator set etc.as required Length of busbar is 0.5 mtr. 34 1 TR Air Conditioning System ,230v/50Hz/Single Phase (Capacity -3400W) Star Rating as per BEE-3Star,Make-MITSUBISHI ELECTRIC INDIA PVT. LTD./approved Rate. 35 Installation of 1 ton Air Conditioner at ground floor building including making suitable length drain line, refrigerent circulation copper wire and fitting fixing outdoor stand of sufficient load bearing capacity and testing the entire set as per direction ofEIC. 36 Servicing & cleaning of existing Air conditioner including refrigarent (Gas) filling , PCB Board,capacitor etc. checking, drain pipe replacement as required to keep the unit healthy condition as per direction and upto the entire satisfaction of EIC. 37 Add GST @ 18% 38 Add Cess @ 1%

Key Value

Document Fees
Refer document
EMD
INR 10300.0 /-
Tender Value
INR 4.95 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail