}

Tender For Shed Construction Work Rajiv Gandhi Stadium Hanumangarh Junction - Dismantling Of Existing Structures Like Culverts, Bridges, Retaining Walls, Cc Road And Other Structure Comprising Of Masonry, Cement Concrete, Wood Work, Steel Work, Including , hanumangarh-Rajasthan

Department Of Local Bodies has published Tender For Shed Construction Work Rajiv Gandhi Stadium Hanumangarh Junction - Dismantling Of Existing Structures Like Culverts, Bridges, Retaining Walls, Cc Road And Other Structure Comprising Of Masonry, Cement Concrete, Wood Work, Steel Work, Including . Submission Date for this Tender is 05-06-2025. Shed Construction Tenders in hanumangarh Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

49270882
Tender For Shed Construction Work Rajiv Gandhi Stadium Hanumangarh Junction - Dismantling Of Existing Structures Like Culverts, Bridges, Retaining Walls, Cc Road And Other Structure Comprising Of Masonry, Cement Concrete, Wood Work, Steel Work, Including
Tender
Indian
Rajasthan
Hanumangarh
05-06-2025

Tender Documents

Tender Details

Tender For Shed Construction Work Rajiv Gandhi Stadium Hanumangarh Junction - Dismantling of existing structures like culverts, bridges, retaining walls, CC road and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 50 metres as directed by Engineer Cement Concrete Grade M-15 and above and PCC blocks 2 Earth work in excavation in foundation, trenches etc. including dressing of sides and ramming of bottoms, including getting out the excavated material, refilling after laying pipe/ foundation and disposal of surplus excavated material at a lead upto 50m suitable site as per direction of Engineer for follwing depths, below natural ground / Road top level.In all types soils/ saturated soil such as moorum, sand, sandy silt,clay, black cotton soil, kankar, etc. Depth upto 1.5 m 3 Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level :1:4:8 (1 Cement : 4 fine/ coarse sand : 8 graded stone aggregate 40mm nominal size). 4 Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level : 1:1½:3 (1 Cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size). 5 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: 6 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work 7 Providing corrugated G.S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete upto any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.80mm thick with zinc coating not less than 275gm/m² 8 Providing and fixing High Intensity retro reflective Type IV sign plate made out of 2.00 mm thick aluminium sheet face to be fully covered with blue/green high intensity grade retro reflective sheet and logo/matters, boarder made of with similar type of white sheeting after etching treatment of aluminium sheet, the black side is to be painted with epoxy grey paint. the plate is to be fixed on 40X40X5 mm angle iron frame with help of aluminium rivets. 9 Providing & Fixing of IK08 IP-66 protected high power LED flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each . Integrated potted driver as a unique BIS R number having efficiency more than 85 % and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy >=125 lm/ wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10% , driver current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector , Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K ±355K. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . High Power LED Flood Light Minimum lumen output 10000 lm 10 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray (with cable tie) including testing etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810. For additional technical parameters of product / work refer Annexure A attached with this BSR 4.0 Sq. mm 4 core

Key Value

Document Fees
INR 1000 /-
EMD
INR 51280.0 /-
Tender Value
INR 25.64 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail