| 1 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For fixed portion Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 2 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 3 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineerin- charge. Pre-laminated particle board with decorative lamination on both sides |
| 4 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness |
| 5 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 300x10 mm |
| 6 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :100 mm |
| 7 | Steel work in built up tubular (round, square or rectangular hollow tubes and welded mesh etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Electric resistance or induction butt welded tubes and welded mesh. |
| 8 | Providing and fixing modular type under bench cabinet over all size 1.70m x 0.70m (or part thereof) 0.60m deep, with one no. Intermediate horizontal partition and two no. Intermediate vertical partitions. The cabinet size shall be fixed two nos. 0.15m deep drawers and shutters in rest of the front area excluding one 1/3rd portion. Prelaminated MDF board of 18mm thickness shall be used except on back sides of cabinet and bottom of drawers which shall be 8mm thickness. The shutters and drawers shall be fixed with 10mm stainless steel C type handles. The shutters shall be fixed with spring hinges and 40mm cupboard locks to approved make. Th e drawers shall be fixed with powder coated telescopic channel of approved make. The exposed edges of board is to be covered with matching lamination 0.8m thick/ painted with epoxy paint matching to the colour of the laminated board, complete as per drawing, design. The MDF board shall be of approved manufacturer, ISI marked conforming to IS: 14587, exterior grade with choice lamination on one side and balancing lamination on other side. Only front area of the cabinet shall be measured for payment. |
| 9 | Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions C.P. brass three outlet swan neck tap complete, including painting of fittings and brackets, cutting and making good the wall wherever required :Size 600x450x200 mm |
| 10 | Providing and fixing of adjustable PVC shoe of size 40mm complete with nut and bolt as per requirement including welding of washer & net on bottom table frame. |
| 11 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer\"s specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work |
| 12 | Providing and fixing machine cut mirror polished black granite 18mm thick in size 1.8m x 0.75m or part there of on table top complete in all respects. |
| 13 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work |
| 14 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominalsize derived from natural sources) |
| 15 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to matchthe shade of tiles, including rubbing and cleaning etc. complete, on 20mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand).Medium shade pigment using 50% white cement 50% Grey cement |
| 16 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. |
| 17 | Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. |
| 18 | Providing & Fixing self adhesive translucent film on glass surface |
| 19 | Providing and fixing zebraMatt roll up double blind of minimum fabric thickness 0.50 mm including head rail, bottom weight rail and all other acessories complete in all respect of vista/Johnson/RC/JM shades(Johnson-dreamline, slimline, combi blackout, combi wood look, italian jute or green guard-bioclean shade, blind magic)or equivatent complete as per manufactures specification of approved shade. The area will be measured i sqmt taking into account the length of head rail and height from Top of head rail to bottom of weight rail |
| 20 | Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm. FRLS insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable etc as required.(Modular Accessories Make: Anchor Roma/ Havells Crabtree/ Wipro North West ). i) Group C |
| 21 | Wiring for circuit/ submain wiring alongwith earthwire with the following size of FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit as required. i) 2x1.5 sqmm + 1x1.5 sqmm earth wire |
| 22 | Wiring for circuit/ submain wiring alongwith earthwire with the following size of FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit as required. i) 2x2.5 sqmm + 1x2.5 sqmm earth wire |
| 23 | Wiring for circuit/ submain wiring alongwith earthwire with the following size of FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit as required.i) 2x4 sqmm + 1x4 sqmm earth wire |
| 24 | Wiring for circuit/ submain wiring alongwith earthwire with the following size of FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit as required. i) 4x10 sqmm + 2x6 sqmm earth wire |
| 25 | Supplying & fixing suitable size GI/ PVC box with modular plate in front on surface or in recess, including providing & fixing 6 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (Modular Accessories Make: Anchor Roma/ Havells Crabtree/ Wipro North West ) |
| 26 | Supplying & fixing suitable size GI/ PVC box with modular plate in front on surface or in recess, including providing & fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. (Modular Accessories Make: Anchor Roma/ Havells Crabtree/ Wipro North West ) |
| 27 | Supplying & fixing 3 pin, 5 Amp ceiling rose on the existing junction box including connection etc as required. |
| 28 | Installation, testing and commissioning of pre wired, fluorescent fitting/ compact fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, inc connection with 1.5 sqmm FRLS insulated, copper conductor, single core cable and earthing etc. as required. |
| 29 | Installation, testing and commissioning of ceiling fan including wiring the down rod of standard length(upto 30 cm)with 1.5 sqmm FRLS insulated, copper conductor, single core cable inc providing and fixing Phenolic laminated sheet cover on the fan box etc. as required. |
| 30 | Supplying & fixing suitable size GI/PVC box with modular plate and cover in front on surface or in recess, including providing and fixing 2 No. 3 Pin 5/6 Amp. Modular socket outlet and 2 Nos. 5/6 Amp. Modular switch, connections etc. as required. ( FOR LIGHT PLUGS TO BE USED IN NON RESIDENTIAL BUILDING).(Modular Accessories Make: Anchor Roma/ Havells Crabtree/ Wipro North West ) |
| 31 | Supplying and fixing following way, horizontal type, Three Pole & Neutral, sheet steel , MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted includingearthing etc. as required.(But without MCB/ RCCB/ Isolator).(Make: Indo Asian/ L&T/ Havells/ Standard). i) 6 way (4+18) , Double door |
| 32 | Supplying and fixing 5 amps to 32 amp. rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make: Indo Asian/ L&T/ Havells/ Standard). i)Single pole |
| 33 | Supplying and fixing 5 amps to 32 amp. rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make: Indo Asian/ L&T/ Havells/ Standard). i) Tripple pole & Neutral |
| 34 | Supplying and fixing DP Sheet Steel Enclosure on surface/ recess along with 25/32 Amp 240 Volt, C curve, DP miniature circuit breakercomplete with connections, testing and commissioning etc. as required. (Make: Indo Asian/ L&T/ Havells/ Standard). |
| 35 | Providing & fixing H.T. Danger notice plate of 250 mm x 200 mm, made of mild steel, atleast 2.0 mm thick, and vitreous enamel white on both side and with inscription with single red colour on front side as required. |
| 36 | Earthing with GI Earth pipe 4.5 mtr long, 40 mm diaincluding accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 37 | Supplying & laying 6.0 SWG GI Wire at 0.50 mtr below ground level for conductor earth electrode including connection/ termination with GI Thimble extra as required. |
| 38 | Supplying, installation, Testing & Commissioning of Panel light 2x2 ft.(System lumen efficacy ≥105 <120 lm/Watt), of following body material and construction as per IS : 10322 with driver as perthe requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified GlareRating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K / 6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS,PVC insulated copper conductor single core cable and earthing etc. asrequired with Minimum 5 year OEM warranty. System lumen efficacy ≥105<120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LEDjunction temperature shall not rise above 90°C). Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mmi) 36 Watt |
| 39 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit,safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS :374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as required.i) 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 40 | Supplying & fixing 400 mm sweep,swing type, 3 blade, wall fan with remote. (Make: Havells/ Bajaj/ Crompton) . |
| 41 | Supplying & fixing Single Phase, 230 volts, Plasticbodyauto shutter exhaust fan / ventilating fan , size 300 mm sweep complete as required. (Make: Bajaj/ Havells/ Crompton) |
| 42 | SITC of cubicle type floor mounted LT panel, Indoor Type factory fabricated made out of CRCA sheet of 1.6 mm thick, fully enclosed and mounted on 50x 50x6 mm thick 600 mm long legs with front openable double door shutter, dust and vermin proof complete with locking arrangement having a system of bus bar of aluminium of suitable size of 400 Amps duly insulated and mounted on epoxy/ porcelain insulators in totally enclosed chambers with three phase and neutral 415 volts AC , Panel prewired with suitable copper wire PVC insulated with all control accessories, provision ofsuitable cable glands, duly powder coated of approved quality over a coat of red primer with sufficient free space complete to include the following accessories:-a)Incomer : 250 Amps, 4 pole, 25 KA MCCB fixed thermal & fixed magnetic release = 01 no. (Make: HPL)outgoing :- i) 63 Amps, 3 pole + Neutral Link, 10 KA, MCCB, Fixed thermal & fixed magnetic release. = 03 No. (Make: HPL)ii) 40 Amps TPN, 10 KA MCB = 03 No.(Make: HPL) iii) Digital VAF Multifunction Meter = 01 Nos.(Make: L&T) iv) R-Y-B indicating lamps = 01 set |