| Sl. No. | Item Description |
| 1 | Taking down cement plaster on brick or concrete surfaces including raking out joints, hacking for key scrubbing down with water etc. complete all as specified and directed by Engineer-in-Charge. |
| 2 | Demolition of brickor stone/boulders masonry, built in cement mortar complete all as specified and directed by Engineer-in-Charge. |
| 3 | Demolition of cement concrete in ground floor and paving n.exe 15 cm thick below or above GL complete all as specified and directed by Engineer-in-Charge. |
| 4 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles from site complete all as specified and directed by Engineer-in-Charge. |
| 5 | Taking down chowkhat or frames with shutters exc 1.5 sqm but n exc 4 sqm each (w/o taking off shutters from the frame) complete all as specified and directed by Engineer-in-Charge. |
| 6 | Taking down chowkhats or frames with shutters (without taking off shutters from the frame) n.exe 1.50 Sqm each complete all as specified and directed by Engineer-in-Charge. |
| 7 | Taking down shutters of anydescription exe 1.00 sqm but n.exe 2.00 sqmeach complete all as specified and directed by Engineer-in-Charge. |
| 8 | Taking down shutters of anydescription n.exe. 1.00 sqm each and removing from site complete all as specified and directed by Engineer-in-Charge. |
| 9 | M&L for PCC 1:2:4 type B-2 (using 40mm graded crushed stone aggregate as in walls or retaining walls any thickness, size or shape including pillasters, buttresses, columns, pillars, boundary pillars and post (including caps and base) complete all as specified and directed by Engineer-in-Charge. |
| 10 | M&L for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted builtin cement mortar 1:4 complete all as specified and directed by Engineer-in-Charge. |
| 11 | M&L forstruck, raised, keyed pointing to stone masonry, random or polygonal rubble uncoursed or brought upto courses in cement mortar 1:3complete all as specified and directed by Engineer-in-Charge. |
| 12 | M&L forbrick work with sub class ‘B’ bricks straight or curved on plan exceeding 6 mtr mean radius in cement mortar 1:4 complete all as specified and directed by Engineer-in-Charge. |
| 13 | M&L for 15mm thick rendering on fair faces of brick work or concrete surfaces in cement mortar 1:4finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge. |
| 14 | M&L for 15mm thick rendering on fair faces of brick work or concrete surfaces in cement mortar 1:6finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge. |
| 15 | M&L for Non skid ceramic coloured joint free tiles 7mm to 8mm thick (square/ rectangular), area of each tiles exceeding 0.11 sqm but n exc 0.18 sqm, in floor etc set and jointed in neat cement slurry and pointed in coloured cement to match the colour of tiles, laid over and including cement screed bed 15 mm thick in cement mortar (1:6) for laying floor finishes complete all as specified and directed by Engineer-in-Charge. |
| 16 | M&L for Non skid ceramic coloured joint free tiles 7mmto 8mm thick (square/ rectangular), area of each tiles exceeding 0.06 sqm but n exc 0.11 sqm, in floor etc set and jointed in neat cement slurry and pointed in coloured cement to match the colour of tiles, laid over and including cement screed bed 15 mm thick in cement mortar (1:6) laying floor finish complete all as specified and directed by Engineer-in-Charge. |
| 17 | M&Lfor 25 mm thick PCC(1:2:4) type B0 using 12.5 mm graded crushed stone aggregate as in floorsto receive floor finishes etc. complete all as specified and directed by Engineer-in-Charge. |
| 18 | M&L for glazed ceramic coloured tiles in vertical surfaces 350 x250x7/450x350x7 mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including 10mm thick cement plaster in cement mortar (1:4)complete all as specified and directed by Engineer-in-Charge. |
| 19 | M&L for 2ndclass hardwood, plain solid straight chowkhats and frames, wrought, framed, rebated on the solid rounded or chamfered, put together with glue, pinned at joints complete all as specified and directed by Engineer-in-Charge. |
| 20 | S&F 2ndclass hard wood 40 mm thick panelled shutters, Plain framed, panelled shutters (one panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated and fixed to chowkhats complete all as specified and directed by Engineer-in-Charge. |
| 21 | Supply and fixed 35mm thick 2ndclass hard woodglazed and skeleton shutters open rebated and prepared to receive glass, gauge etc (internal sash bars) edges of framing plane, chamferred or rounded fitted and mitred beads for securing glass etc size of members as specified in SSR Part-I Section 8 clause8.24(a)(kail) complete all as specified and directed by Engineer-in-Charge. |
| 22 | S&F for30 mm thick 2nd class hard woodglazed and skeleton windows/ ventilators shutters open rebated and prepared to receive glass, gauge etc., divided into squares with plain, chamferred or rounded, mitred and rebated sash bars any numbers, provided with stiles and rails as specified in SSR part I section 8 clause 8.24 (b) complete all as specified and directed by Engineer-in-Charge. |
| 23 | S&F Factory made solid PVC door frame of size 50mm x 47mm made out of 5 mm single side prelaminated PVC sheet reinforced with MS square tube manufactured as per SSR Part-I specifications and drawings complete all as specified and directed by Engineer-in-Charge. |
| 24 | S&F factory made solidPVC door shutters 30mm thick (style) consisting of frame made out of MS tube for top and bottom rails MS frame shall be covered with heat moulded plain colour PVC \"C\" channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail lock rail and bottom rail on either side and gap insert for top rail and bottom rail panelling of plain colour PVC to sheet to be fitted in the MS frame welded / sealed to the styles and rails with suitable PVC sheet beading and joined together with solvent cement complete all as specified and directed by Engineer-in-Charge. |
| 25 | S&F aluminium alloy, anodised, sliding door bolt of length 300 mm with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts ofsections or cast-aluminium extruded alloy and fixed complete all as specified and directed by Engineer-in-Charge. |
| 26 | S&F aluminium anodised barrel tower bolts extruded section of size 200 mm, complete all as specified and directed by Engineer-in-Charge. |
| 27 | S&F aluminium anodised barrel tower bolts extruded section of size 150 mm long , complete all as specified and directed by Engineer-in-Charge. |
| 28 | S&F aluminium handle extruded fabricated type anodised of size 150 mm complete all as specified and directed by Engineer-in-Charge. |
| 29 | S&F forbutt hinges 100mm medium weight cold rolled mild steel complete all as specified and directed by Engineer-in-Charge. |
| 30 | S&F for butt hinges 75 mm medium weight cold rolled mild steel complete all as specified and directed by Engineer-in-Charge. |
| 31 | S&F MS rat tail spring including roller & roller plate complete 300 mm size complete all as specified and directed by Engineer-in-Charge. |
| 32 | S&F 150 mm long floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring complete all as specified and directed by Engineer-in-Charge. |
| 33 | M&L for fixed in repairs4mm thick sheet glass ordinary quality and glazing with oil putty or fixed with bead/glazing pins in squares n.exc 0.5 Sqm in each pane including hacking out old glass panes complete all as specified and directed by Engineer-in-Charge. |
| 34 | M&L for 4mm thick sheet glass ordinary quality and glazing with oil putty or fixed with bead/glazing pins in squares n.exc 0.5 Sqm in each pane complete all as specified and directed by Engineer-in-Charge. |
| 35 | M&L for 4mm thick figured glass pin headed typeand glazing with oil putty or fixed with bead/glazing pins in squares n.exc 0.5 Sqm in each pane including hacking out old glass panes complete all as specified and directed by Engineer-in-Charge. |
| 36 | S&F galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm complete all as specified and directed by Engineer-in-Charge. |
| 37 | S&F in repairsgalvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm complete all as specified and directed by Engineer-in-Charge. |
| 38 | M&L in repairs for 20mm thick pre-polished graniteslabs, machine cut, in vertical/horizontal surfaces over and including 15mm cement plaster in cement mortar (1:4) and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of the granite stone including grinding and polishing complete all as specified and directed by Engineer-in-Charge. |
| 39 | M&L for 75 mm thick PCC (1:3:6) type C2 (using40 mm graded crushed stone aggregate ) as insub base for receiving floor finishes etc. complete all as specified and directed by Engineer-in-Charge. |
| 40 | M&Lfor chequered cement concrete tiles 30cmx30cmx25mm thickwithgrey cement and pigment, set, jointed and pointed in neat cement slurry in floors laid over 15 mm thick screed bed in cement mortar1:6 complete all as specified and directed by Engineer-in-Charge. |
| 41 | Dismantling water storage tanks of any description, exc 250 & n.exc 500 litres capacity and removing from site complete all as specified and directed by Engineer-in-Charge. |
| 42 | S&F for Rotational moulded polyethylene 500 litres capacity waterstorage tank (Cylindrical vertical with closed top), 3 layer hoisted and fixed in position including 20 mm ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball complete all as specified and directed by Engineer-in-Charge. |
| 43 | S&F in repair vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) including connections of flush pipe to squat pattern closet including lime concrete bedding and all joint making good to the floor complete all as specified and directed by Engineer-in-Charge. |
| 44 | S&F in repair vitreous chinabowl urinal flat back, size of 465 x 355 x 265 mm white (min), with grating and union for discharge pipeincluding flushing system, flush pipe & wate pipe) complete all as specified and directed by Engineer-in-Charge. |
| 45 | S&F in repairs floor stainless steel gratings , 125mm dia complete all as specified and directed by Engineer-in-Charge. |
| 46 | S&F in repair PVC valveless 10 litre capacity syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, complete all as specified and directed by Engineer-in-Charge. |
| 47 | S&F in repair Vitreous chinawash hand basin,Vitreous chinawhite, flat back, size 550 x 400 mm with brackets, including cutting for and pinning in ends of brackets or erecting stand complete all as specified and directed. (Including 15mm bore CP pillar tap, waste coupling and 32mm dia PVC waste pipe) complete all as specified and directed by Engineer-in-Charge. |
| 48 | S&F in repairs 15 mm size PVC connection with PTMT nuts of 600 mm long complete all as specified and directed by Engineer-in-Charge. |
| 49 | S&F in repairs swivel shower of PTMT any colour with arm, 195 mm long with bend of 45 degree with flange (both min wt 80 gms ) complete all as specified and directed by Engineer-in-Charge. |
| 50 | S&F 110 PVC (SWR) WC connector bent type complete all as specified and directed by Engineer-in-Charge. |
| 51 | S&F costiron Nahani trap 75 mm dia including jointing to pipe complete all as specified and directed by Engineer-in-Charge. |
| 52 | S&F in repairs 15 mm bore fancy typeCP bib tapscast copper alloy with crutch or butterfly nuts , handle, screwed down for iron pipe complete all as specified and directed by Engineer-in-Charge. |
| 53 | S&F & repairs, 15 mm bore CPstop valve cost copper alloy screwed down , high pressure with crutch or butterfly handlefancy typecomplete all as specified and directed by Engineer-in-Charge. |
| 54 | S&F in repairs, 15 mm bore stop valves, CP fancy type, chromium plated with long shank and cup (concealed type) cost copper alloy screwed down, high pressurefancy typecomplete all as specified and directed by Engineer-in-Charge. |
| 55 | S&F600 x 450mm bevelled edge mirror of selected quality glass mounted on 6mm thick PVC sheetand 3 mm th PVCmoulded framearound the glass with chromium plated brass screws and cup washers includingprovision of hanging hooks and sheet glass shelf assemble consisting of 5.5 mm thick sheet, 12 cm wide with chromium plated brackets guard and railing 60 cm long complete all as specified and directed by Engineer-in-Charge. |
| 56 | Taking upor down 15mm bore GI Tubing and connections including cleaning for refixing or removal to store complete all as specified and directed by Engineer-in-Charge. |
| 57 | Taking upor down 20mm bore GI Tubing and connections including cleaning for refixing or removal to store complete all as specified and directed by Engineer-in-Charge. |
| 58 | S&F 15 mm bore GI tubing medium grade galvanised with all fittings and fixed complete to walls & floors etc. complete all as specified and directed by Engineer-in-Charge. |
| 59 | S&F 20mm bore GI tubing medium grade galvanised with all fittings and fixed complete all as specified and directed by Engineer-in-Charge. |
| 60 | S&F in repairs brass chromium plated tubular towel rail with brackets, 20mm dia, D type, 60 cm long between flanges complete all as specified and directed by Engineer-in-Charge. |
| 61 | S&F in repairs vitreous china wash down water closet pan ( pedestal pattern ) white complete including ‘P’ or ‘S’ trap , seat cover and fixing to flushing cistern, brackets, flushing pipeetc.complete all as specified and directed by Engineer-in-Charge. |
| 62 | S&F in repairs 15 mm borebrass CP mixer for mixing hot and cold waterscrewed down high pressure with long screwed shanks and fly nuts screwed for iron pipes complete all as specified and directed by Engineer-in-Charge. |
| 63 | S&F in repairs Ball valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for 20mm dia iron pipe and fixed (minimum weight 15mm-142gms/20mm 210gms/25mm 455gms/40mm 690gms) complete all as specified and directed by Engineer-in-Charge. |
| 64 | S&F in repairsPillartap 15mm chromium plated fancy type cast cooper alloy with crutch or butter fly handle, screwed down for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge. |
| 65 | S&F in repairsbibtap 15mmPTMT any colour high pressure screwed down for iron pipe and fixed ( Minimum weight 90gms) complete all as specified and directed by Engineer-in-Charge. |
| 66 | S&F in repairs 20 mm bore gun metal globe or gate valve with iron wheel head screwed head both for iron pipe & fixed complete all as specified and directed by Engineer-in-Charge. |
| 67 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks,etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed by Engineer-in-Charge. |
| 68 | S&F in repairs75mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed on walls/floor complete all as specified and directed by Engineer-in-Charge. |
| 69 | S&F in repairs110 mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed on walls/floor complete all as specified and directed by Engineer-in-Charge. |
| 70 | S&F 75mm PVC (SWR) bends any radius complete all as specified and directed by Engineer-in-Charge. |
| 71 | S&F 110mm PVC (SWR) bends any radius complete all as specified and directed by Engineer-in-Charge. |
| 72 | S&F 110mmPVC (SWR) vent cowl complete all as specified and directed by Engineer-in-Charge. |
| 73 | S&F 75mm PVC (SWR) vent cowl complete all as specified and directed by Engineer-in-Charge. |
| 74 | Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/slabs, weather boardings, plywood including cover fillets etc. complete all as specified and directed by Engineer-in-Charge. |
| 75 | S&F for anodised aluminium snap grid of size 605 x605 mm frame work for false ceiling including straining with GI wire4 mm thick complete all as specified and directed by Engineer-in-Charge. |
| 76 | S&F for 10mm thick PVC insulation panels with EPS stuck to 1 mm thick plain PVC sheet suitably placed in false ceiling grid made of aluminiumGI/MS as per specification and drawing complete all as specified and directed by Engineer-in-Charge. |
| 77 | S&F Hollow PVC wall panelling decorative typeconsisting of 5 mm thick plain colour PVCpre-laminated sheet inclusive of solvent cement and fixing at site on PVC frame/wooden frame as per specification and drawing complete all as specified and directed by Engineer-in-Charge. |
| 78 | S&F for 5 mm thick PVC sheet fillets of width 35 mm for wall panelling inclusive of fixing on to wall to make PVC frame as per specification and drawing complete all as specified and directed by Engineer-in-Charge. |
| 79 | S&F for 9 mm thick veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on one faces, fixed with screw to timber frame onwall and ceiling etc. complete all as specified and directed by Engineer-in-Charge. |
| 80 | S&F 2nd class soft woodplain fillets square rectangular or triangular in section clean sawn fixed with nails Sectional area exc 06but not exc 13sqcm complete all as specified and directed by Engineer-in-Charge. |
| 81 | S&F in repairs 40mm thick , 2nd class class hardwood planks , planed one side with butt joints and fixed with nailsfixed in any situation complete all as specified and directed by Engineer-in-Charge. |
| 82 | M&L in repairs for weather boarding in 2nd class hardwood clean sawn , plain , 20 mm thick or feather edeged, 15 mm to 20 mm thick and fixed with 30 mm laps joints complete all as specified and directed by Engineer-in-Charge. |
| 83 | Dismantling timber scantling 40 sqcm and over in section in any position in framed work complete all as specified and directed by Engineer-in-Charge. |
| 84 | S&F in repairs timber frame in second class hard wood as in scantling etc. complete all as specified and directed by Engineer-in-Charge. |
| 85 | M&L for 15mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:3finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge. |
| 86 | M&L treatment to sunken slab by applying evenly a coat of blown type bitumen at the rate of 1.50 kg per square m and binding with clean dry sand @ 0.05 cum per sqm complete all as specified and directed by Engineer-in-Charge. |
| 87 | M&L for polyethylene film, 150 micron thick, laid on a coat of bitumen primer @ 0.30 to 0.50 kg per sqm complete all as specified and directed by Engineer-in-Charge. |
| 88 | M&L for 100mm thick PCC 1:2:4 type B1 20mmgraded aggregate as in padding of sunken slabs etc to required in slope in sunken finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge. |
| 89 | Dismantling plain or corrugated steel sheeting any gauge, thickness including roof covering etc. complete all as specified and directed by Engineer-in-Charge. |
| 90 | S&F Pre-painted galvalume aluminium zinc coating Gi based corrugated steel sheet 0.5mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge. |
| 91 | S&F Pre-painted galvalume aluminium zinc coating Gi based plain steel sheet 0.5mm thick of an colour having tensile strength of 550 Mpa as in roof ridge etcfixed with self tapping screws complete all as specified and directed by Engineer-in-Charge. |
| 92 | Dismantling structural steel work including doors, gates, rails, grills, gratingsetc. complete all as specified and directed by Engineer-in-Charge. |
| 93 | Dismantling structural steel framed trusses etc n exc 10m complete all as specified and directed by Engineer-in-Charge. |
| 94 | S&Fmild steel work for Hand rails, half round or other stock section , nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts and similar work conforming to Fe 290gde E 165 complete all as specified and directed by Engineer-in-Charge. |
| 95 | S&F mild steel framed work such as grills, grating etc with guard bars, framed guard bars,hold fasts, railing, framed work of water tanks and similar work confirming to Fe-290 gde-E165. complete all as specified and directed by Engineer-in-Charge. |
| 96 | M&L for applying3 mm thick wall care putty on wallincluding preparation new surfaces plastered or unplasteredsurfaces complete all as specified and directed by Engineer-in-Charge. |
| 97 | S&F in repairs plain mild steel wire, 4.0 mm dia galvanised class 3 in detached work such as mosquito nets and fixing including straining bolts, hooks, eyes etc. complete all as specified and directed by Engineer-in-Charge. |
| 98 | S&F roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. fe-410 (gde E-250) complete all as specified and directed by Engineer-in-Charge. |
| 99 | S&F plates (plain or chequered) channels, distance pieces, cleats etc. square cut or notched including riveted, bolted or welded attachment complete all as specified and directed by Engineer-in-Charge. |
| 100 | M&L for 50 mm thick PCC ( 1:3:6) type C-2 using 40mm garde stone aggregate as in plinth protection etc. complete all as specified and directed by Engineer-in-Charge. |
| 101 | M&L for preparing plastered or un plastered NEW surface of walls and applying two coats of Cement base paint on walls a coat of alkali-resistant primer complete all as specified and directed by Engineer-in-Charge. |
| 102 | M&L for applying3 mm thick wall care putty on wallincluding preparation new surfaces plastered or unplasteredsurfaces complete all as specified and directed by Engineer-in-Charge. |
| 103 | M&L for preparation of new plastered surface of wall and applying two coats of oil bound distemper over a coat of Priming plastered and other surfaces with alkaliresistant priming paint complete all as specified and directed by Engineer-in-Charge. |
| 104 | M&L for preparing plastered or un plastered new surface of walls and applying three coats of white wash on walls complete all as specified and directed by Engineer-in-Charge. |
| 105 | M&L for plastered or un plastered OLD SURFACES of walls and applying two coats of Cement base paint on walls (External)including removal of existing treatment complete all as specified and directed by Engineer-in-Charge. |
| 106 | Material and labour for applying one coat of cement base paint to old treated plastered or un-plastered surfaces of wall including preparation of surface (by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and treating oil and greasy spots) complete all as specified and directed by the Engineer-in-Charge. |
| 107 | Material and labour for applying one coat of OBD to old treated surfaces of wall including preparation of old surface of walls (by washing down, rubbing down and stopping of distempered surface) complete all as specified and directed by Engineer-in-Charge. |
| 108 | Material and labour for preparation of old painted wooden surfaces and applying one coat of synthetic enamel paint of any description, not otherwise described, over 10 cm width or girth including preparaton of surfaces complete all as specified and directed by Engineer-in-Charge. |
| 109 | M&L for preparation of old decorated CGI Sheet surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel pait (in camouflage/plain pattern) complete all as specified and directed by Engineer-in-Charge. |
| 110 | Material and labour for applying one coat of white washto old treated plastered or un-plastered surfaces of wall including preparation of surfaces (by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and treating oil and greasy spots) complete all as specified and directed by the Engineer-in-Charge. |
| 111 | Material and labour for applying one coat of white washto old treated plastered or un-plastered surfaces of ceiling including preparation of surface (by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and treating oil and greasy spots) complete all as specified and directed by the Engineer-in-Charge. |
| 112 | M&L for preparation of old surfaces of wall and applying two coats of cement base paint complete as per manufactures instructions complete all as specified and directed by Engineer-in-Charge. |
| 113 | Material and labour for complete removal of existing treatment old surface of wall and applying two coat of oil bound distemper over alkali resistant primer incl 1mm thick wall care putty complete all as specified and directed by the Engineer-in-Charge. |
| 114 | Material and labour for applying two coat of synthetic enamel paint to old painted wooden surfaces of any description, not otherwise described, over 10 cm width or girth including preparation of surfaces complete all as specified and directed by Engineer-in-Charge. |
| 115 | M&L for preparation of old decorated CGI Sheet surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint (in camouflage/plain pattern) complete all as specified and directed by Engineer-in-Charge. |
| 116 | Supply and fix MCB Distribution board, 240 volts single pole andneutral ,double door, sheet steel, enclosure powder coated with 200 Amps rated busbar with neutral link, 4 ways , fixed on wall duly grouted in solid block wall or on wooden board with electrical connectionincluding taking down old unserviceable DBand taken as credit includingcomplete all as specified and directed by Engineer-in-Charge. |
| 117 | Supply and fix MCB Distribution board, 240 volts single pole andneutral ,double door, sheet steel, enclosure powder coated with 200 Amps rated busbar with neutral link, 8 ways , fixed on wall duly grouted in solid block wall or on wooden board with electrical connectionincluding taking down old unserviceable DBand taken as credit includingcomplete all as specified and directed by Engineer-in-Charge. |
| 118 | Supply and fix MCB Distribution board, 240 volts single pole andneutral ,double door, sheet steel, enclosure powder coated with 200 Amps rated busbar with neutral link, 12 ways , fixed on wall duly grouted in solid block wall or on wooden board with electrical connectionincluding taking down old unserviceable DBand taken as credit includingcomplete all as specified and directed by Engineer-in-Charge. |
| 119 | Supply and fix MCB Distribution board, 415volts triple pole andneutral ,double door, sheet steel, enclosure powder coated with 200 Amps rated busbar with neutral link, 4 ways , fixed on wall duly grouted in solid block wall or on wooden board with electrical connectionincluding taking down old unserviceable DBand taken as credit including complete all as specified and directed by Engineer-in-Charge. |
| 120 | Supply and fix MCB Distribution board, 415volts triple pole andneutral ,double door, sheet steel, enclosure powder coated with 200 Amps rated busbar with neutral link, 6 ways , fixed on wall duly grouted in solid block wall or on wooden board with electrical connectionincluding taking down old unserviceable DBand taken as credit includingcomplete all as specified and directed by Engineer-in-Charge. |
| 121 | Supply and fixing 240V, 10 KA \"B\" curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 Amps in the MCB DB complete with connection testing and commissioning complete all as specified and directed by Engineer-in-Charge. |
| 122 | Supply and fixing 240V, 10 KA \"B\" curve miniature circuit breaker (MCB) of single poles and current carrying capacity 40 to 63 Amps in the MCB DB Complete with connection testing and commissioning complete all as specified and directed by Engineer-in-Charge. |
| 123 | Supply and fixing 240V, 10KA \"C\" curve miniature circuit breaker (MCB) ofcurrent carryingSPN 32 Amps capacity in the MCB DB complete with connection testing and commissioningcomplete all as specified and directed by Engineer-in-Charge. |
| 124 | Supply and fixing 240V, 10KA \"C\" curve miniature circuit breaker (MCB) ofcurrent carryingSPN 40-63Amps capacity in the MCB DB complete with connection testing and commissioningcomplete all as specified and directed by Engineer-in-Charge. |
| 125 | Supply and fixing 415V 10KA \"B\" curve miniature circuit breaker (MCB) ofcurrent carrying capacity TPN40 to 100 Amps in the DB complete with connection testing and commissioning complete all as specified and directed by Engineer-in-Charge. |
| 126 | Supply and fix MCCB 4 Pole, 415 V, Adjustable type, 250 Amps with breaking capacity 36 KA complete all as specified and directed by Engineer-in-Charge. |
| 127 | Supply and fix MCCB 4 Pole, 415 V, Adjustable type, 350 Amps with breaking capacity 36 KA complete all as specified and directed by Engineer-in-Charge. |
| 128 | Supply and fixing in repairs Automatic source change over with current limiter 30/20A single phase ACCL complete all as specified and directed by Engr-in-Charge. Make Havells Cat Part No DHABOSN3020 OR Equivalent in Indoasian/L&T |
| 129 | Supply and fixingin repair off load change over switch onload 415 volts TPN in sheet metal enclosure with side handleof capacity 63Amps complete all as specified and directed by Engineer-in-Charge.Make:Indoasian Cat Part No : OFFP0063 or equivalent inHavells/Standard |
| 130 | Supply and fixing in repair off load change over switch onload 415 volts TPN in sheet metal enclosure with side handleof capacity 32 Amps complete all as specified and directed by Engineer-in-Charge.Make:Indoasian Cat Part No : OFFP0032 or equivalent inHavells/Standard |
| 131 | Supply and replacement ofSingle pole and neutral enclosure with a two pin and earth plug and socket complete with one single poleMCB 230 Volts 20Amps complete all as specified and directed by Engineer-in-Charge. |
| 132 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed by Engineer-in-Charge. |
| 133 | Point wiring for one light point/fan point/bell pointcontrolled by one switch with 1.5 sqmm PVC FRLS insulated unsheathed copper conductor single core multi strand flexible cable and 1.5 sqmm PVCinsulated unsheathed copper conductor single core cable (green color) as earth lead in and including PVC casing and capping/Conduit mediumgrade of suitable size run on wall/surface with all fittings (ISI Marked) controlled by one switch including CI/MS sunk box of required size or PVC Gang Box all as directed by Engr in Charge & 3mm thick plastic laminated sheet, including cutting chases to wall making good the disturbed surfaces to match with theexisting specification complete all as specified and directed by Engineer-in-Charge. |
| 134 | All as per Srl item No-133 here in above but for one 3 pin 5A socket outlet independent controlled by one switch complete all as specified and directed by Engineer-in-Charge. |
| 135 | All as per Srl item No-133 here in above but for one 5A socket outlet on the same board controlled by one switch complete all as specified and directed by Engineer-in-Charge. |
| 136 | All as per Srl item No-133 here in above but for one 3 pin 15 Amps socket outlet independentwith 2.5 sqmm PVCinsulated unsheathed copper conductor single core multi strand flexible cable and 1.5 Sqmm PVC FRLS insulated unsheathed copper conductor single core cable (green color) as earth lead complete all as specified and directed by Engineer-in-Charge. |
| 137 | M&L forsubmain wiring with two singlecore PVC insulated flexible copper conductor cable of size 4 sqmm and one single core PVCinsulated flexible copper conductor cable green colour of size 2.5 Sqmm as earth lead in & including concealed PVC casing capping medium grade2mm thickness ISI marked or cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with existing specification including taking down old unserviceable complete all as required at site or directed by Engr-in- charge. |
| 138 | M&L forsubmain wiring with two singlecore PVC insulated flexible copper conductor cable of size 6 sqmm and one single core PVC insulated flexible copper conductor cable green colour of size 4 Sqmm as earth lead in & including concealed PVC casing capping medium grade2mm thickness ISI marked cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with existing specification including taking down old unserviceable complete all as required at site or directed by Engr-in- charge. |
| 139 | M&L forsubmain wiring with two singlecore PVC insulated flexible copper conductor cable of size 2.5sqmm and one single core PVC insulated flexible copper conductor cable green colour of size 1.5Sqmm as earth lead in & including concealed PVC casing capping medium grade2mm thickness ISI marked cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with existing specification including taking down old unserviceable complete all as specified and directed by Engineer-in-Charge. |
| 140 | M&L Switch piano flush button single pole one way 5 amps 240 volts complete all as specified and directed by Engineer-in-Charge. |
| 141 | M&LSocket2 in 1, 5 Amps flush type, 230 volts complete all as specified and directed by Engineer-in-Charge. |
| 142 | M&L Switch piano flush button single pole one way 15 amps 240 volts complete all as specified and directed by Engineer-in-Charge. |
| 143 | M&LSocket5/15 amps flush type, 230 volts complete all as specified and directed by Engineer-in-Charge. |
| 144 | M&L Ceiling rosesurface Bakelite 2 to 3 terminals complete all as specified and directed by Engineer-in-Charge. |
| 145 | Supply and fixingfan regulator electronic, step type hum free suitable to control speed of fan from 0 to 100% and connecting electrically complete all as specified and directed by Engineer-in-Charge. |
| 146 | S & F Lamp holder insulated body with back plate for batten fittings complete all as specified and directed by Engineer-in-Charge. |
| 147 | S&F bell push flush type 6 Amps 240 Volt complete all as specified and directed by Engineer-in-Charge. |
| 148 | S&F bell/buzzer AC 230 volts single pole complete all as specified and directed by Engineer-in-Charge. |
| 149 | Supply & fix Rigid non-metallic PVC conduit of size 25 mm dia, exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed by Engineer-in-Charge. |
| 150 | Supply and fix in replacement cable PVC FRinsulated unsheathed with flexible multistranded copper conductor of size1.5 Sqmm 1100 Volts grade as per site requirement of existing colour coding adopted complete all as specified and directed by Engineer-in-Charge. Make : Havells : Basic code No : WHFFDN1.5L11X57/HPL or equivalent in Plaza, Polycab |
| 151 | Supply and fix in replacement cable PVC FRinsulated unsheathed with flexible multistranded copper conductor of size2.5 Sqmm 1100 Volts grade as per site requirement of existing colour coding adopted complete all as specified and directed by Engineer-in-Charge.Make : Havells : Basic code No : WHFFDN2.5L11X57/HPL or equivalent in Plaza, Polycab |
| 152 | Supply and fix in replacement cable PVC FRinsulated unsheathed with flexible multistranded copper conductor of size4.0 Sqmm 1100 Volts grade as per site requirement of existing colour coding adopted. Make : Havells : Basic code No : WHFFDN4.0L11X57/HPL or equivalent in Plaza, Polycab |
| 153 | Supply and layingin replacement1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flator circulartwin core4 sq. mmcomplete all as specified and directed by Engineer-in-Charge. |
| 154 | Supply and layingin replacement1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flator circulartwin core10 sq. mmcomplete all as specified and directed by Engineer-in-Charge. |
| 155 | Supply and layingin replacement1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flator circulartwin core16 sq. mmcomplete all as specified and directed by Engineer-in-Charge. |
| 156 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engineer-in-Charge. |
| 157 | Supply and fix surface and wall mounted LED batten 20 Watt ( white/ warm white) with aluminium housing & integrated electronic driver, extruded Aluminium heat sink provided for efficient heat dissipation, LED life time of 30000* hours complete all as specified and directed by Engineer-in-Charge.Make: HavellsCat Part No:LUMILINEPLUSNEOBS20WLED830SPCSSIND or equivalent /Bajaj/Crompton/Philips |
| 158 | Supply and fixing LED luminaire 600 mm x 600 mm, 36 watt( White/ Warm White) , 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed by Engineer-in-Charge. |
| 159 | Supply and fixing round/squareshape 15 watt ( white/Warm white) 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engineer-in-Charge. |
| 160 | S&F LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engineer-in-Charge. |
| 161 | Supply and fixing Decorative wall light fixture made up of Polycarbonate, suitable for 9 W retrofit LED lamp B22 base including 9 watt LED lamp with necessary connection of suitable twisted copper flexible wire complete all as specified and directed by Engineer-in-Charge.Make : Havells cat Part NoLHDL02160099/ Philips/ Bajaj |
| 162 | Taking down the old unserviceable Bed lamp fitting and taken as credit including Supply, Installation, testing and commissioning of LED bed side/ Wall light fitting with system wattage not more than 4W, using 3W for LEDs. The lumen output of LED shall be (Light source) shall not less than 230 lumens. The housing shall be of aluminium and white color coating. The head of the luminaries shall be adjustable type. The beam angle shall be < 50 deg. Lamp lifetime up to: 15,000 hrs. Total lumen output fixture: > 170 lm. Bulb technology: LED, Safety Extra Low Voltage. Mains power: Range 220 V–240 V, 50-60 Hz. IP code: IP20, protection against objects bigger than 12.5 mm, no protection against water. Class of protection: I - earthed. The luminaries shall be integrated type. TheNet weight shall not exceed 0.3 kg complete all as specified and directed by Engineer-in-Charge. make: PHILIPS 56240/31/16 STAR or equivalent inEglo 93154 Single LED Lamp or HAVELLS/ SYLVANIA 0050990 |
| 163 | Supply and fixing LED 25 Watt (WW)post top in spherical shape polycarbonate diffuser & IP 65 protection, electronic Driver should be in-built , power factor >0.9 with THD <10%. with necessary connection of suitable size of flexible copper cablecomplete all as specified and directed by Engineer-in-Charge.Make : Bajaj Cat Part No BLPTSP 25W LED WW or equivalent in Havells /Philips |
| 164 | Material & labour for earthing complete with galvanised cast iron earth plate electrode of size 600x600x6.0mm thick busied directly in ground less than 3.0m deep below normal ground level as earth electrode with top edge of the earth plate not less than 2.25mtr below ground level using GI wire 4.00mm dia as earth continuity conductor connected to earth plate by means of welding, GI thimbles, nuts, bolts & washers all as directed including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and RCC pit coverwith handle of angle iron frame of size 40 x 40 x 6mm in PCC 1:3:6 adequate quantity of charcoal dust and salt and kalmi shora all around the earth plate, earth work in any type of soil remaining surplus excavated material all as required at site and specified in EP No 3 of SSR part I 2009 or directed by Engineer-in-charge and including testing on completion. (i) Main earthing lead from earth plate electrode to test point up to length of 7.5 meters length shalldeemed to be included in the unit rate quoted against this item .(ii) GI protection pipe & earthing lead beyond 7.5 meter shall be measured and paid for separately under appropriate item of Sch A. (iii) On testing after completion if the desired resistance is not obtained the contractor shall redo the earthing without any extra cost to the department . |
| 165 | M&L painting of ceiling fan complete , using spray gun, in site with synthetic enamel paint by spraying including filling cavities with filler , one coat after cleaning all dust complete all as specified and directed by Engineer-in-Charge. |
| 166 | M&L for replacement of capacitor 2/3.15 mfdAC 230 volts50 Hz complete all as specified and directed by Engineer-in-Charge.Make : Asian/Jyoti/Usha /Apcos |
| 167 | M&L for replacement of capacitor 4 mfdAC 230 volts50 Hz complete all as specified and directed by Engineer-in-Charge.Make : Asian/Jyoti/Usha /Apcos |
| 168 | M&L for replacement of ball bearing for ceiling fan /exhaust fan any size any make complete all as specified and directed by Engineer-in-Charge.Make : SKF/NBC/ABC. |
| 169 | M&L for replacement of gun metal bush with suitable size, gun metal bush for ceiling fan any make, any size and sweep complete all as specified and directed by Engineer-in-Charge. |
| 170 | M&L for rewinding of AC ceiling fan/wall mounting fan motor as existing at siteany make with super enamelled copper winding wire any gauge from 0.315mm to 0.193mm including cutting of old burnt winding. Sleeve work varnishing with `B\" class insulation varnish, connection with flexible wire of appropriate size two core copper wire upto connector block qty of copper winding wire not less than 350 grms and not more than 500 grms per fan motor, replacement of capacitor 2 mfd, complete all as specified and directed by Engineer-in-Charge. |
| 171 | M&L for rewinding of exhaust fan motor any size, from 225 to 400 mm sweep with supper enamelled copper wire of any size ranging from 0.500mm to 0.285 mm including necessary cutting of old burnt winding wire, cleaning of slots and provision of necessary threading/sleeve work and taking out connection in lead with PVC copper wire of appropriate size upto connector block, capacitor 2/3.15 mfdcomplete all as specified and directed by Engineer-in-Charge. |
| 172 | Taking down carefully geyser 25/35/50 ltrs capacity from wall after unscrewing nuts/bolts etc. and again refixing in position after repair and replacement of spare parts including testing complete all as specified and directed by Engineer-in-Charge. (spare parts shall be measured and paid for separately under respective items) |
| 173 | M&L for replacement of unserviceable heating element AC 230 Volt of rating 1500W ISI mark (triangular/round) as per existing any type complete all as specified and directed by Engineer-in-Charge. |
| 174 | M&L for replacement of unserviceable heating element AC 230 Volt of rating 2000W ISI mark (triangular/round) as per existing any type complete all as specified and directed by Engineer-in-Charge. |
| 175 | M&L for replacement of unserviceable thermostat switch AC 230 Volt adjustable range from 0-90 degree Celsius complete all as specified and directed by Engineer-in-Charge. |
| 176 | M&L for replacement of unserviceable Indicator lamp round/square type suitable for geyser 25-50 ltrs all as per sample AC 230 Volts complete all as specified and directed by Engineer-in-Charge. |
| 177 | M&L for replacement of unserviceable auto cut switch suitable for geyser 25-50 ltrs all as per sample AC 230 Volts complete all as specified and directed by Engineer-in-Charge. |
| 178 | M&L for replacement of unserviceable geyser assembly suitable for geyser 25-50 ltrs all as per sample AC 230 Volts complete all as specified and directed by Engineer-in-Charge. |
| 179 | M&L for replacement of flexible PVC connection pipe heavy duty suitable for hot water to bear the temp of 100 degree centigrade with outlet and inlet connection brass adopters , washers of size 450 mm long 15 mm dia borecomplete all as specified and directed by Engineer-in-Charge. |
| 180 | Supply and fixing for (in repairs)Plug top 3 pin 15 amps 230 volts including taking oldplug top complete all as specified and directed by Engineer-in-Charge. |
| 181 | Supply and fixing of LED7 wattbulb ( White/warm white) complete all as specified and directed by Engineer-in-Charge.Make-Havells/Philips/Bajaj |
| 182 | M&L for sunken boxcast iron/ pressed steelterminal boxes 60mm deep 6x8 for mounting of switch/socket on hylum sheet and including hylam sheet , screws etccomplete all as specified and directed by Engineer-in-Charge. |
| 183 | M&L forsunken boxcast iron/ pressed steelterminal boxes 60mm deep 8x10 for mounting of switch/socket on hylum sheet and including hylam sheet , screws etccomplete all as directed by Engr-in- Charge at site. |
| 184 | M&L forsunken boxcast iron/ pressed steelterminal boxes 60mm deep 10x12 for mounting of switch/socket onhylam sheet and including hylum sheet , screws etccomplete all as specified and directed by Engineer-in-Charge. |
| 185 | Supply & fix for (in repairs) medium gradePVC casing and cappingof size 20 mm dia, exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc including taking down old unserviceable casing & caping complete all as specified and directed by Engineer-in-Charge. |
| 186 | Supply and fixing (in repairs)PVC Gang box surface type suitable for fixing of 5 pin 15 Amp multipurpose switch socket on wall complete all as specified and directed by Engineer-in-Charge. |
| 187 | Supply and fixing (in repairs)PVC Gang box surface type suitable for fixing of 5 pin 5 Amp multipurpose switch socket on wall complete all as specified and directed by Engineer-in-Charge. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy