| 1 | Dismantling, asbestos cement, corrugated or semi-corrugated sheets in roofs incl ridge, complete all as specified and directed. |
| 2 | Dismantling, plain, corrugated or semi-corrugated steel sheeting, any gauge, thickness, incl Nainital pattern & similar in roof coverings incl ridge, complete all as specified and directed. |
| 3 | M&L 6mm thick asbestos cement,corrugated or semi corrugated sheets in roofs,walls etc fixed with L-type or J-type or cranked hook bolt,complete all as specified and directed. |
| 4 | M&L 6mm thick Asbestos cement two piece adjustable serrated ridge forcorrugated or semi corrugated sheets fixed with L-type or J-type or cranked hook bolt, complete all as specified and directed. |
| 5 | S & F Pre-painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an coulourhaving tensile strength of 550 Mpa as in roof coveringfixed with self tappingscrews complete all as specified and directed. |
| 6 | Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strenth of 550 Mpa as in roof covering/ridge fixed with self tappingscrews complete all as specified and directed. |
| 7 | Dismantling timber scantlings 40 sq. cm and over in section, in any position, framed work, complete all as specified and directed. |
| 8 | S&F Roof trusses (framed), trussed, purlins, rafters, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel, flat, hollow sections) including distance pieces, cleats, welding/rivets/nut/bolts/washer etc, complete all as specified and directed. |
| 9 | S&F M S Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts;posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 10 | 2nd class hard wood scantling, clean sawn, timber framed work andfixed , complete all as specified and directed. |
| 11 | Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets, complete all as specified and directed. |
| 12 | Providing and fixing of V-board-\"Visaka\"/E-board \"Everest\" make 600x600x4mm thick white prelaminated seif embosed reinforced designer ceiling board tiles of approved texture at all height laid on Hot dipped Galvanised iron imposed grid with 24 mm wide T-section exposed flanges which shall be power coated white. The frame work shall comprise of main runner made from 0.33mm thick G S sheet and of size 24x32x3000mm and spaced at 1200mm centers securely fixed to the structural soffits by approved hangers at 1200mm maximum centers. Hangers/suspended with 2 run of 2 mm dia of GI wire to be fixed by approved rawl plug, level and justers and screws etc. The last hanger at the end of each main runner shall be greater than 450mm from adjacent wall. Flush fitting of 1200mm long cross tee (with double stitching) to be interlocked between main runners at 600mm center to form 1200x600mm modules cross tee longer than 600 mm to be supported independently.600x600 mm modulesto be formed by fitting 600 mm long cross Tee centrally between the 1200mm cross tee. Tee, Perimeter wall angle shall be of 0.45mm thick GS shgeet of size 19x19mm and 300 mm long of white colour all as specified by manufacture instruction. |
| 13 | S&F factory madePVC wall panellingof density 600Kg/cbm manufacured by an ISO 900-2008 certified company. 5 mm thick sheetsincluding fillets forwalland also manufacurer\"s test report and test certificate is mandotary with each and every supply of the material complete all as specified and directed. |
| 14 | Taking down cement plaster/dado (terrazzo) on brick/concrete or stone walls, ceiling, etc, including raking out joints, hacking for key, scrugbbing down with water etc, complete all as specified and directed. |
| 15 | Rendering 15mm thick on brick work or concrete surfaces in CM 1:4,surfaces finished even and smooth (without using extra lime or cement), complete all as specified and directed. |
| 16 | Rendering 10 mm thick in CM 1:6 on brick work or concrete surfaces and finished even and smooth without using extra cement, complete all as specified and directed. |
| 17 | Rendering 05 mm thick in concrete surface in CM 1:3 in ceiling and finished even and smoothwithout using extra cementcomplete all as specified and directed. |
| 18 | Demolition of brick work or stone masonry, built in cement mortar incl all quoins, arches pillars etc complete all as specified and directed. |
| 19 | M&L of brick work withsub class\"B\" burnt old size bricks straight or curved on planexc. 6 m mean radius bult in CM 1:6 complete all as specified and directed. |
| 20 | All as per srl item No.18 above but except bricks,complete all as specified and directed. |
| 21 | S&F in repair 5mm thick Polycarboneted roof sheet of 1st quality complete all as specified and directed. |
| 22 | M&L for copings /coping/bed blocks in PCC 1:2:4 Type B-1 ( using 20mm gr. Cr. stone aggr)at junction of parapet wall & roof fixing of truss etc complete all as specified and directed. |
| 23 | M&L for preparation of new or previously untreated surface ofsteel or iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 24 | Complete removal of existing water proofing treatment of any description incl under layer, taking down of cement plaster/demolition of cement concrete any thickness and removal of debris off the premisesincluding grubbing up of trees and preparation of concrete surfaces by scrubbing down with steel brushes and cleaning with water to remove all loose dirt/dust, complete all as specified and directed. |
| 25 | M&L for P.C.C 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in padding over roof finished and laid to required slope complete all as specified and directed. |
| 26 | M&L Rendering 15mm thck in CM 1:4 on Concrete surfaces of rooffinished fair & even and including mixing of water proofing compound (WPC shall be measured and paid separately), complete all as specified and directed. |
| 27 | M&Lforwater proofing treatment inthe following sequences:-(a) Applying1st course of bituminous primer conforming to IS -3384 @ 0.4 Kg/Sqm cover the surface till the surface properly impregnated and insolvent oil primer evoporate completely(bi) Applying2nd coat of blown 85/25 graded bitumen confirming to IS 702 @ 1.2 Kg/sqm. (C)Applying 3rd course of APP (Atactic Polypropylene) modified polymeric membrane 3 mm thick weight not less than 3.6 Kg/Sqm with 160 Grams/Sqm non woven polyester made at centre core reinforced laid with 75 mm side overlap and 100 mm overlap. The membrane has to be laid with LPG torch and overlap sealed and finished neat complete all as specified and directed . |
| 28 | M&L for preparation of newly sufrace of APP Membrane and applying two coats of water based bituminious alumunium paint @ 200 ml per sqm etc, complete all as specified and directed. |
| 29 | Disconnecting existing tanks, cap exc 500 ltr and not exc 1000 ltr setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position, complete all as specified and directed. |
| 30 | S&FRotational moulded polye- thylene water storage tanksof capacity 500 ltrs (cylindrical vertical with closed top) hoisted and fixed in position including all necessary connections all as specified in SSR Part I& incl dismentling old U/S, complete all as specified and directed. |
| 31 | S&F Rotational moulded polye- thylene water storage tanksof capacity 1000 ltrs (cylindrical vertical with closed top) hoisted and fixed in position including all necessary connections all as specified in SSR Part I & incl dismentling old U/S, complete all as specified and directed. |
| 32 | S& F in repair 20mm bore ball valves high pressure of PTMT with epoxy coated Aluminiumrod& highdensity plastic ball screwed for iron pipe and fixed, complete all as specified and directed. |
| 33 | M&L for two coats of cement based paints over one coat of primer incl preparation to newly plastered surfaces of walls etc complete all as specified and directed. |
| 34 | Preparation of new plastered surfaces of wall and applying two coats of oil bound distemper over in inicludinig 3mm wall care putty, complete all as specified and directed. |
| 35 | Preparation of new plastered surfaces of ceiling and applying three coats of white wash, complete all as specified and directed. |
| 36 | Preparation of old plastered surfaces of wall and applying one coat of cement base paint on old decorated surfaces complete all as specified and directed. |
| 37 | Preparation of old plastered surfaces of ceiling and applying one coat of white wash, on old decorated surfaces complete all as specified and directed. |
| 38 | Preparation of old plastered surfaces of wall and applying one coat of oil bound distemper on old decorated surfaces complete all as specified and directed. |
| 39 | Preparation of New wooden surfaces having width/girth exceeding 10 cm including necessry putty filling with knife of same colour where required to achieve smooth and even surface and applying two coat of synthetic enamel paint over one coat of pink primer on wood surfaces of any description( up to 2nd storey with necessary scaffolding)complete all as specified and directed. |
| 40 | Taking down eaves gutters and PVC rainwater pipes (any size or pattern), including all fittings,heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories), complete all as specified and directed. |
| 41 | S&Fin repair PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and directed. |
| 42 | S&F in repair PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 43 | S&F in repair PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 44 | S&F in repair PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and directed. |
| 45 | S&F PVC (SWR) floor trap, 75mm dia outlet, plain with grating including jointing with solvent cement complete all as specified and directed. |
| 46 | S&F PVC (SWR) 110mm bore bends any radius |
| 47 | S&F PVC (SWR) 75mm bore bends any radius |
| 48 | S&F PVC (SWR) 110mm bore bends any radius with access door |
| 49 | S&F PVC (SWR) 75mm bore vent cowl complete all as specified and directed |
| 50 | S&F PVC (SWR) 110mm bore branch piece, single (single Y) equal orunequal, complete all as specified and directed. |
| 51 | Taking down GI pipe 15mm bore steel tubing and connections including cleaning for refixing or removal to store complete all as specified and directed |
| 52 | S&F G.I. pipe 15mm bore tubing medium grade galvanised with all fitting fixed to wall, ceiling and laid in floors complete all as specified and directed |
| 53 | Cutting chases,pining in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landing steps, cills, sunshades ,shelves,lintels,etc.; and cutting chases for concealed water tubing or concealed conduit,wiring,etc,and making good cutting not exceeding 10 cm girth in brick walls, complete all as specified and directed. |
| 54 | Taking down GI pipe 20mm bore steel tubing and connections including cleaning for refixing or removal to store complete all as specified and directed. |
| 55 | S&F G.I. pipe 20mm bore tubing medium grade galvanised with all fitting fixed to wall, ceiling and laid in floors complete all as specified and directed. |
| 56 | M&L in repair to old broken chajjas & facia by removing loose position of concrete / plaster and making the surfaces in line, level and plumps by applying the cement plaster in cement mortar 1:3 of thick not lessthan10 mm including dubbing out in thesame mortar or in cement concrete 1:1.5:3 as per the site requirement upto height 8mtr and in any position, complete all as specified and directed.NOTE- Rate quoted shall be deemed to include for scaffolding / formwork for single/ double story building of height upto 8.0 mtrs and making good the disturbed surfaces,complete |
| 57 | Taking down shutters of any description n.exc 1.00 Sqmeach and removing from the site complete all as specified and directed. |
| 58 | Taking down shutters of any description exc 1.00 Sqm and n.exc. 2.00 sqm each and removing from the site complete all as specified and directed. |
| 59 | Taking down chowkats or frames with shutter (without taking off shutter from the frame) n.exc 1.5 Sqm each including cutting holes for taking out hold fast or dismantling brick work and removing from siteall as specified. |
| 60 | Taking down chowkats or frames with shutter (without taking off shutter from the frame)exc 1.5 Sqm&n.exc 4 Sqm each including cutting holes for taking out hold fast or dismantling brick workand removing from site complete all as specified and directed. |
| 61 | S&F pressed steel framesof size 125mm x 60mm made outof size 1.25mm thick MS sheet for doorssingle rebated including mild steel hinges medium weight 100 mm long and 25mm x 3mm flat iron in holdfast,tie bar including necessary fixinglugs, hold fast, lock strike plate and fixing arrangement etc complete as specified and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-1 including PCC 1:3:6 as in back fill to chowkats complete all as specified and directed. |
| 62 | S&F pressed steel framesof size 105mm x 60mm made outof size 1.25mm thick MS sheet for doorsdouble rebated including mild steel hinges medium weight 100 mm long and 25mm x 3mm flat iron in holdfast,tie bar including necessary fixinglugs, hold fast, lock strike plate and fixing arrangement etc complete as specified and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-1 including PCC 1:3:6 as in back fill to chowkats complete all as specified and directed. |
| 63 | Supply and fixing Factory made, plain framed, panelled shutter (two/single Panel) 35mm thick,2nd class Hardwood with lock rail and panel of 9 mm B.W.P commercial ply. The size of rail and stiles as per as per IS:1003 (Part-I),kiln seasoned and chemically pressure treated complete all as specified and directed. |
| 64 | Supply and fixing 35mm thick2nd Class hard wood glazed,gauzed and skelton shutters open rebated and prepare to receive glass, gauge etc but divided into squares with plain chamfered or rounded mitredand rebatedsash bars,stiles and rails as specified in SSR Part-I Sec 8 clause 8.24 (a)complete all as specified and directed. |
| 65 | S&F Flush shutters, 30 mm thick solid core construction, with both side Lemination of any approved colour and shade,complete all as specified and directed. Note :- Sampel approved byGE. |
| 66 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm Plain colour PVC sheet reinforced with mild steel square tube, supplying and fixing in opening as per specifications and drawing including making good to disturbed surface of walls, complete all as specified and directed. |
| 67 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppplyingand fixing in the frame at site as per specification & drawing complete all as specified and directed. |
| 68 | Material & labourfactory made steel windows double shutter box type, outer frame made out of ERW TUBE \"P\" section (60x45x25mm) and shutters of ERW TUBE \"P\" section (50x35x20mm) operable shutters side hung includding pistol hinges with two Nos of MS Tower bolts 150mm size on each shutter steel handle and stopper of \"Z\" section as specified complete with sash bars devetailed or welded ready for glass fixing and wire gauzed fixing with suitabel fittings/openning for cooler/AC where required .Steel windows will be double shutter external glazed and internal wire gauzed complete all as specifed and as per Drg No CEPZ/TD-324/07 1/3 to 3/3 all as specified and directed by Engr-in-Charge.NOTE: The quoted rate against the above item shall also include (i) 04 Nos MS Steel lugs of 20x5mm MS flat 20cm long over all welded to frames (ii) PCC block for embedding lugs. |
| 69 | Ditto all as per item No 67 but in Ventilators any size. |
| 70 | S&F Powder Coated Aluminium door shutter including frame of hollow section 101mm x 44.00mm xthickness not less than 1.53 mm including aluminium anodized powder coated of hollow section glazed shutter of stiles size 85mm x 44.45mm xthickness not less than 1.56mm having grooves for aluminium beading and top rail of hollow section 83.5mm x 44.45mmxthickness not less than 1.50mm, lock rail of hollow section 83.5mm x 44.45mm xthickness not less than 1.50mm and bottom rail of hollow section 114.3mm x 44.45mmx thickness not less than 1.50mm ,one derived handle 300mm long,100mm long butt hinges or aluminium floor type hydraullic door closer, aluminium mortice lock 65mm 4 levers of Godrej make and glazing with select quality tinted glass 5mm thick or panelling with ACP sheet and cleat rubber packing aluminium beading including aluminium hardware fitting complete all as specified and directed. |
| 71 | M&L Aluminum Power coated, sliding windows three track with mosquito proofing with style 44.4x44.5x2mm thick including 4 mm thick coloured/tinted/frosted glass panes including all necessary fittings and fixturescomplete all as specified and directed. |
| 72 | Anodised aluminium grills, 6mm dia size 100x100mmfixed to aluminium windowsand thickness of powder coating not less than 50 micron, complete all as specified and directed. |
| 73 | Hacking out old broken glass (any thickness,size quality or description) from any types of wooden/steel/alum (up to 4th storey) frames or stone concrete or brick surrounds glazed with putty or fixed with beads. |
| 74 | S&F3.5 mm thick sheet glass ordinary quality glazing with oil putty or any type of beads in square n.exc. 0.5 Sq each pane in any type of frame of iron/Steel/Wood/Aluminium as required at site complete all as specified (uptofourth storey with necessary scaffolding), complete all as specified and directed. |
| 75 | S&F 3.5 mm thick figured glass, pin head type and glazing with oil putty or any type of beads in square n.exc. 0.5 Sq each pane in any type of frame of iron/Steel/Wood/Aluminium as required at site complete all as specified (uptofourth storey with necessary scaffolding), complete all as specified and directed. |
| 76 | Supply and fixing Galvanised mildsteelwire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specifiedfixed with stainless steel wire staples. |
| 77 | Supply and fixingin repair Galvanised mildsteelwire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specifiedfixed with stainless steel wire staples. |
| 78 | S&F Aluminium anodised, barrel tower boltssize 150 mm of extruded section and fixed complete all as specified and directed. |
| 79 | S&F butt hinges of mild steel cold rolled medium weight of size 100mm complete all as specified and directed. |
| 80 | S&F Aluminium handles, fabricated type, anodised Size-100mm, anodised section and fixed complete all as specified and directed. |
| 81 | S&F Aluminium alloy, anodised, sliding door bolt Size- 250 mmwith hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed. |
| 82 | Note:- The contract sum arrived after deduction of amount of Sch of credit as listed in tender Documents. |