Tender For Provision Of Klp At Samba; 1 Schedule A Part-I.Constructions of Administrative Building (G+1) complete all as specified and as shown in drgs. 2 Construction of Car, Bicycle and scooter shed for Adm Office complete all as specified and as shown in drgs. 3 Construction of Single living Accn for officers (S/S) complete all as specified and as shown on drgs. 4 Construction of Car Garages for Offrs Mess (04 Nos) + Single Offrs (02) and Servant Qtrs (10) (G+1) complete all as specified and as shown on drgs. 5 Construction of Offrs Mess (11 to 18) (S/S) complete all as specified and as shown on drgs. 6 Construction of JCO Mess Club (41 to 60) and single living accn (15 Nos) & parking for car and scooter (G+2) complete all as specified and as shown on drgs. 7 Construction of Single Living Accn for 79 ORs and 26 HAVs (G+3) along with cook house and dinning hall complete all as specified and shown on drgs. 8 Construction of single living accn for 60 ORs and 12 HAVs (G+3) along with cook house and dinning hall complete all as specified and as shown on drgs. 9 Construction of single living accn for 53 ORs and 16 HAVs (G+3) along with cook house and dinning hall complete all as specified and shown on drgs. 10 Construction of scooter shed for single living accn ORs/ HAVs (For 60 scooters) complete all as specified and as shown on drgs. 11 Construction of scooter shed for single living accn ORs/ HAVs (For 100 scooters) complete all as specified and as shown on drgs. 12 Construction of Guard house, SAA store, Armour Shop and Armouries (S/S) complete all as specified and as shown on drgs. 13 Construction of Storage Accn (S/S) complete all as specified and as shown on drgs. 14 Construction of Instruction room & Instruction store/shed (G+1) complete all as specified and as shown on drgs. 15 Construction of OR’s Institute (S/S) complete all as specified and as shown on drgs. 16 Construction of Station Store (S/S) complete all as specified and as shown on drgs. 17 Construction of Drying and Ironing room & mechanical laundary (S/S) complete all as specified and as shown on drgs. 18 Construction of Religious Institute hall complete all as specified and as shown on drgs. 19 Construction of URC + Family Welfare Centre (G+1) complete all as specified and as shown on drgs. 20 Construction of Guard Room complete all as specified and as shown on drgs. 21 Construction of Elevated Sentry Postcomplete all as specified and as shown on drgs. 22 Construction of Incinerator complete all as specified and as shown on drgs. 23 Construction of Fire point complete all as specified and as shown on drgs. 24 Construction of Alarm post complete all as specified and as shown on drgs. 25 Construction of PCC hard standing as per drg No CEPZ/C-TD/007/13 Sht 1/2 and 2/2 complete all as specified and as directed by Engineer-in-Charge and shown on drgs. 26 Construction of Garbage and Refuse Bin complete all as specified and shown on drgs. 27 Lumpsum price worked out by the contractor for Site Clearance works as listed in Schedule A Part-II. 28 Lumpsum price worked out by the contractor for Iinternal Water Supply works as listed in Schedule A Part-III. 29 Lumpsum price worked out by the contractor for Internal Electricfication works as listed in Schedule A Part-IV. 30 Lumpsum price worked out by the contractor for Protective works as listed in Schedule A Part-V. 31 Lumpsum price worked out by the contractor for Road, Path and culvert worksas listed in Schedule A Part-VI. 32 Lumpsum price worked out by the contractor for Sewage Disposal works as listed in Schedule A Part-VII. 33 Lumpsum price worked out by the contractor for Area Drainage works as listed in Schedule A Part-VIII. 34 Lumpsum price worked out by the contractor for External Water Supply works as listed in Schedule A Part-IX. 35 Lumpsum price worked out by the contractor for External Electrification works as listed in Schedule A Part-X. 36 Lumpsum price worked out by the contractor for Security Fencing and Steel gate works as listed in Schedule A Part-XI. 37 Lumpsum price worked out by the contractor for Demolition and Dismantling works as listed in Schedule A Part-XII. 38 CHIMNEYSupply and fixelectric stainless steel commercial chimney of capacity 1250CFM/hr of size 6 feet hood and size 2 feet length (30 inch in length each with BLDC motor of suitable size ) with LED light , purfreted filter complete along with fixing with help of angle bold complete all as specified by manufarcturer and making hole for flexible exhaust pipe through cutting of wall and making outlet at outside the kitchen area complete all as specified. 39 External ElectrificationM & L for construction of platform of size 3000 x 2500 x 1200 mm for transformer withPCC (1:4:8)in foundation andPCC 1:2:4 type B1, 100 mm thicknessat top portion of platform , brick work with cement mortar (1:4) and complete plaster work of 15 mm thick to exposed surfacein CM (1:4) including necessary MS work ( i.e. MS jali/fencing/MS angle ) on the top of platform around transformer up to height 90 cm and one coat of white wash on plastered surface complete all as shown on drawing No CEPZ/C-TD/002/13 Dated 2/5 and all as specified . 40 Supply, install, testing and commissioning of 11 KV, 350 MVA,630 A rating, 21.3 KA (Short time current rating), 2 Way, indoor VCB with EnclosureMotorized type as per Specification with 1 incoming and 1 Outgoing VCB complete all as specified and directed by Engineer-in-Charge.Location: Sub station No 02 GE Samba office inside campus ( 01 incoming +01 Out going) 1. Each Incomer feeder with Switch consists of: (a) Motorized 630 A , 350 MVA VCB enclosure with built in earth switch with full making capacity-01 Nos(b) Mechanical position indicator. Switch ON/OFF/Earthed-01 No(c ) Live cable indication-01 No(d) Cable compartment cover interlocked with earth switch-01 No.(e) Cable termination bushing-01 Nos for 3 Core 95 Sqmm HT cable.(f) 11 KV XLPE Cable termination Kit with boot-01 Set(g)NO/NC contact for -01 Set(i) Isolator ON/OFF (ii) Earth Switch ON/OFF (iii) Fault indicator Operated.(h) Command Output for -01 Set(i) Isolator close(ii) Isolator Open(iii) FPI Reset(j) Anti Pumping Relay -01 Nos 41 (k) Digital MFM (EM646 or equvt) -01 Nos. (l) Indications: (i) ON/OFF/Trip Indication Light -01 Sets.(ii) Spring Charge Healthy indication-01 Nos. (iii) Trip Circuit Healthy Indication-01 Nos. (iv) Test / Service Postion Indicator-01 Set. (n) Breaker Control Switch-01 Nos.Make: (o) L/R Switch-01 Nos(q) 3 pin Plug and socket-01 Nos. (r) Toggle switch-01 Nos. (s) Hooter-01 Nos.(t) Annuniciator 8 Watt-01 Nos. (u) 24 V DC Power Pack, 17 Ah-01 Nos. (v) Door switch-01 Nos. (w) Space Heater with thermostat-01 Nos. (x) Control MCB set comprisiong ofSPN MCBs as per relays and meters. -01 Set . (y) Cable termination bushings suitable for 2 Nos 3 C x 95 Sq mm XLPE cable -01 Sets each one for one Incoming VCB(z) 11 KV Screened cable termination kit with boots-01 sets each one for one Incoming VCB2. Each Outgoing feeder with Switch consists of: (a) 11 KV VCB enclosure 630 Amps, 350 MVA,21.3 KA(Short time current rating), Electronic draw out VCB, coil voltage 24 VDC -04 sets. 42 (b) 11 KV Dual core CTs 500/5--04 Nos. (c ) Core Cl1:1.0, 15VA -04 set. (d)Core Cl2:5P10,15VA-04 set. (e) Relays:- 3 Over current, 1 Earth Fault Relay with TCS and RS Port (50,51,50N, 51N, 95) -04 Nos. (f) Master Trip Relay-04 Nos. (g) Anti Pumping Relay -04 Nos. (h) Meters:(i) Digital Ammeter with selector siwtch Cl-1.0-04 Nos. (ii) Digital MFM (EM646 or equvt) -04 Nos. (j) Indications: (i) ON/OFF/Trip Indication Light -04 Sets.(ii) Spring Charge Healthy indication-04 Nos. (iii) Trip Circuit Healthy Indication-04 Nos. (iv) Test / Service Postion Indicator-04 Set. (k) Breaker Control Switch-04 Nos.(l) L/R Switch-04 Nos.(m) LED bulb-04 Nos. (n) 3 pin Plug and socket-04 Nos. (o) Toggle switch-04 Nos. (p) Hooter-04Nos. (q) Annuniciator 8 Watt-04 Nos. (r) Door switch-04 Nos. (s) Space Heater with thermostat-04 Nos.(t) Control MCB set comprisiong ofSPN MCBs as per relays and meters. -04 Set 43 (u) Cable termination bushings suitable for 1 No 3 C x 95 Sq mm XLPE cable -01 Set (Each set have 3 bushings) each one for one OutgoingVCB. (v) 11 KV Screened cable termination kit with boots-01 sets (Each set have 3 bushings) each one for one Outgoing VCB(vi) Common items per VCB.(a) Gas pressure indicator with auxillary contacts.(b) 1 No. Handle per RMU(c) Battery & Battery Charger3. Civil workThe platform for placing VCB as per manufacturers technical drawing and made suitable PCC ducting for laying cable and fill with reuired level fine sand on treches all as specified and directed by Engr-in-Charge. commong items: (i) Battery & Battery charger.(ii) Warning board marking as HT 11 KV Danger with skull and writing with English, Hindi, local language. 44 Supply ,Installation ,testing & commisioning of totally enclosedfeeder piller box outdoor type(IP-65) fabricated out of 3.15 mm thick CRCA sheet angled frameddust and vermin proof powdercoated double door type(independent cabin including locking arrangementforeach MCCBs and provide space spreader for all MCCBs, bus bar chamber (enclosed) including locking arrangement complete suitable for operating on 415 Volt50 Hz AC, supply internally wired with copper conductor , TPN bus bar of aluminium strip (4 Nos) insulated by heat shrinkable sleaves & clips on shrouds for joints busbar shall be designed to withstand a fault lavel at 415 Volts having legs 45 cms made out of 65x65x6 mm angle iron grouted on brick masonary plateform upto 30 cms .Brick masonary plateform should be 60 cms abovethe Ground Level.Comprising the following : (Main LT Panel No 1)(i) The panel shall be front operated with cable entry from the bottem with cable glands. (ii) Fabrication of feeder piller box to be approved by CPRI width of the panel not less than 60cmsNote:- Cost for construction of plateform for panel of brick masonary work in CM 1:6 with foundationPCC 1:4:8 type D-2including plaster work ,PCC copping 1:2:4 (40 mm thick stone aggerate ) ,deemed to be included in the item rate .No extra payment will be made. 45 (Note: This panel shall be a front operated with cable entry from the bottom .The fault with standing capacity shall be 25 KA .Earth bus shall be part of the main feeder pillar.) (a) ACBs 1000 amps , 50 KA ,FP, 415 volt 50 Hz- 01 Nos (for Incoming) (b) MCCB 4 pole, 400A, 415 volt 50HZ with thermal setting 70% to 100% and rupturing capacity not less than 36 KA - 01 Nos (for out going).(c) MCCB 4 pole, 250 A, 415 volt 50HZ with thermal setting 70% to 100% and rupturing capacity not less than 36 KA - 01 No (for out going).(d) MCCB 4 pole, 200 A, 415 volt 50HZ with thermal setting 70% to 100% and rupturing capacity not less than 36 KA - 02 Nos (for out going).(e) MCCB 4 pole, 160 A, 415 volt 50HZ with thermal setting 70% to 100% and rupturing capacity not less than 36 KA - 01 No (for out going).(f) MCCB 4 pole, 100A, 415 volt 50HZ with thermal setting 70% to 100% and rupturing capacity not less than 16 KA - 02 Nos (for out going).(g) MCB SPN 40 aMPS, - 02 Nos (for out going).(h) Digital Ammeter 0 to 1000 Amp with selector switch & suitable range of CTs - 01 No.(j) Digital Voltmeter 0 to 500 V with selector switch - 01 No.(k) LED phase indicating lamp (Set of three)- 03 Nos (RYB) 46 Supply ,Installation ,testing & commisioning of totally enclosedfeeder piller outdoor type(IP-65) fabricated out of 3.15 mm thick CRCA sheet dust and vermin proof powdercoated double door type(independent cabin including locking arrangementforeach MCCBs and provide space spreader for all MCCBs , bus bar chamber (enclosed) including locking arrangement complete suitable for operating on 415 Volt50 Hz AC, supply internally wired with copper conductor , TPN bus bar of aluminium strip (4 Nos) insulated by heat shrinkable sleaves & clips on shrouds for joints busbar shall be designed to withstand a fault lavel at 415 Volts having legs 45 cms made out of 65x65x6 mm angle iron grouted on brick masonary plateform upto 30 cms .Brick masonary plateform should be 60 cms abovethe Ground Level.Comprising the following : (LT Panel No 4 JCOs Mess)(i) The panel shall be front operated with cable entry from the bottem with cable glands. (ii) Fabrication of feeder piller box to be approved by CPRI width of the panel not less than 60cms Note:- Cost for construction of plateform for panel of brick masonary work in CM 1:6 with foundationPCC 1:4:8 type D-2including plaster work ,PCC copping 1:2:4 (40 mm thick stone aggerate ) ,deemed to be included in the item rate .No extra payment will be made. 47 (Note: This panel shall be a front operated with cable entry from the bottom .The fault with standing capacity shall be 25 KA .Earth bus shall be part of the main feeder pillar.) (a) MCCB 4 pole, 100 A, 415 volt 50HZwith thermal setting 70% to 100% and rupturing capacity not less than 36 KA - 01 No (for Incoming). (b) MCCB 4 pole, 40 A, 415 volt 50HZ with thermal setting 70% to 100% and rupturing capacity not less than 16 KA - 01 No (for out going). (c ) MCCB 4 pole, 25 A, 415 volt 50HZ with thermal setting 70% to 100% and rupturing capacity not less than 16 KA - 02 Nos (for out going). (d)MCB SPN 6 to 32 amps 240 Volt- 01 Nos (outgoing)(e) Digital Ammeter 0 to 500 Amp with selector switch & suitable range of CTs - 01 No .(f) Digital Voltmeter 0 to 500 V with selector switch - 01 No.(g) LED Phase indicating lamp (Set of three)- 03 Nos (RYB) 48 Supply ,Installation ,testing & commisioning of totally enclosedfeeder piller outdoor type(IP-65) fabricated out of 3.15 mm thick CRCA sheet dust and vermin proof powdercoated double door type(independent cabin including locking arrangementforeach MCCBs and provide space spreader for all MCCBs, bus bar chamber (enclosed) including locking arrangement complete suitable for operating on 415 Volt50 Hz AC, supply internally wired with copper conductor, TPN bus bar of aluminium strip (4 Nos) insulated by heat shrinkable sleaves & clips on shrouds for joints busbar shall be designed to withstand a fault lavel at 415 Volts having legs 45 cms made out of 65x65x6 mm angle iron grouted on brick masonary plateform upto 30 cms. Brick masonary plateform should be 60 cms abovethe Ground Level.Comprising the following : (LT Panel No SM Barrick)(i) The panel shall be front operated with cable entry from the bottem with cable glands. (ii) Fabrication of feeder piller box to be approved by CPRI width of the panel not less than 60cmsNote:- Cost for construction of plateform for panel of brick masonary work in CM 1:6 with foundationPCC 1:4:8 type D-2including plaster work ,PCC copping 1:2:4 (40 mm thick stone aggerate ), deemed to be included in the item rate.No extra payment will be made. 49 (Note: This panel shall be a front operated with cable entry from the bottom .The fault with standing capacity shall be 25 KA .Earth bus shall be part of the main feeder pillar.)(a) MCCB 4 pole, 400 A, 415 volt 50HZwith thermal setting 70% to 100% and rupturing capacity not less than 36 KA - 01 No (for Incoming). (b) MCCB 3 pole, 63A, 415 volt 50HZ with thermal setting 70% to 100% and rupturing capacity not less than 16 KA - 06 Nos (for out going).(c ) MCCB 3 pole, 25A, 415 volt 50HZ with thermal setting 70% to 100% and rupturing capacity not less than 16 KA - 01 No (for out going).(d) MCB SPN 10-32 Amps, 10 KA , 240 v-01 No (for Outgoing)(e) Digital Ammeter 0 to 500 Amp with selector switch & suitable range of CTs - 01 No.(f) Digital Voltmeter 0 to 500 V with selector switch - 01 No.(g) LEDPhase indicating lamp (Set of three)- 03 Nos (RYB) 50 Supply ,Installation ,testing & commisioning of totally enclosedfeeder piller outdoor type(IP-65) fabricated out of 3.15 mm thick CRCA sheet dust and vermin proof powdercoated double door type(independent cabin including locking arrangementforeach MCCBs and provide space spreader for all MCCBs, bus bar chamber (enclosed) including locking arrangement complete suitable for operating on 415 Volt50 Hz AC, supply internally wired with copper conductor, TPN bus bar of aluminium strip (4 Nos) insulated by heat shrinkable sleaves & clips on shrouds for joints busbar shall be designed to withstand a fault lavel at 415 Volts having legs 45 cms made out of 65x65x6 mm angle iron grouted on brick masonary plateform upto 30 cms. Brick masonary plateform should be 60 cms abovethe Ground Level.Comprising the following : (LT Panel No Laundary )(i) The panel shall be front operated with cable entry from the bottem with cable glands. (ii) Fabrication of feeder piller box to be approved by CPRI width of the panel not less than 60cmsNote:- Cost for construction of plateform for panel of brick masonary work in CM 1:6 with foundationPCC 1:4:8 type D-2including plaster work, PCC copping 1:2:4 (40 mm thick stone aggerate ), deemed to be included in the item rate.No extra payment will be made. 51 (Note: This panel shall be a front operated with cable entry from the bottom .The fault with standing capacity shall be 25 KA .Earth bus shall be part of the main feeder pillar.)(a) MCCB 4 pole, 200 A, 415 volt 50HZwith thermal setting 70% to 100% and rupturing capacity not less than 16 KA - 01 No (for Incoming) .(b) MCCB 3 pole, 160 A, 415 volt 50HZ with thermal setting 70% to 100% and rupturing capacity not less than 16 KA - 1 No (for out going).(c ) MCCB 3 pole,25, 415 volt 50HZ with thermal setting 70% to 100% and rupturing capacity not less than 16 KA - 03 Nos (for out going).(d)MCB SPN 6 to 32 amps 240 Volt- 06 Nos (outgoing)(e) Digital Ammeter 0 to 500 Amp with selector switch & suitable range of CTs - 01 No.(f) Digital Voltmeter 0 to 500 V with selector switch - 01 No.(g) LEDPhase indicating lamp (Set of three)- 03 Nos (RYB) 52 Supply ,Installation ,testing & commisioning of totally enclosedfeeder piller outdoor type(IP-65) fabricated out of 3.15 mm thick CRCA sheet dust and vermin proof powdercoated double door type(independent cabin including locking arrangementforeach MCCBs and provide space spreader for all MCCBs , bus bar chamber (enclosed) including locking arrangement complete suitable for operating on 415 Volt50 Hz AC, supply internally wired with copper conductor , TPN bus bar of aluminium strip (4 Nos) insulated by heat shrinkable sleaves & clips on shrouds for joints busbar shall be designed to withstand a fault lavel at 415 Volts having legs 45 cms made out of 65x65x6 mm angle iron grouted on brick masonary plateform upto 30 cms .Brick masonary plateform should be 60 cms abovethe Ground Level.Comprising the following : (LT Panel No 5 near Offr Mess)(i) The panel shall be front operated with cable entry from the bottem with cable glands. (ii) Fabrication of feeder piller box to be approved by CPRI width of the panel not less than 60cmsNote:- Cost for construction of plateform for panel of brick masonary work in CM 1:6 with foundationPCC 1:4:8 type D-2including plaster work ,PCC copping 1:2:4 (40 mm thick stone aggerate ) ,deemed to be included in the item rate .No extra payment will be made. 53 (Note: This panel shall be a front operated with cable entry from the bottom .The fault with standing capacity shall be 25 KA .Earth bus shall be part of the main feeder pillar.)(a) MCCB 4 pole, 250 A, 415 volt 50HZwith thermal setting 70% to 100% and rupturing capacity not less than 36 KA - 01 Nos (for Incoming) .(b) MCCB 3 pole 125 A, 415 volt 50HZ with thermal setting 70% to 100% and rupturing capacity not less than 16 KA - 01 No (for out going).(c) MCCB 3 pole 100 A, 415 volt 50HZ with thermal setting 70% to 100% and rupturing capacity not less than 16 KA - 01 No (for out going).(d) MCCB 3 pole 63 A, 415 volt 50HZ with thermal setting 70% to 100% and rupturing capacity not less than 16 KA -1 No (for out going).(e) MCCB 3 pole 32 A, 415 volt 50HZ with thermal setting 70% to 100% and rupturing capacity not less than 16 KA -1 No (for out going).(f) MCCB 3 pole 25 A, 415 volt 50HZ with thermal setting 70% to 100% and rupturing capacity not less than 16 KA - No (for out going).(g)MCB SPN 6 to 32 amps 240 Volt - 12 Nos (out going)(h) Digital Ammeter 0 to 200 Amp with selector switch & suitable range of CTs - 01 No.(i) Digital Voltmeter 0 to 500 V with selector switch - 01 No.(j) LEDPhase indicating lamp (Set of three)- 03 Nos (RYB) 54 Supply ,Installation ,testing & commisioning of totally enclosedfeeder piller outdoor type(IP-65) fabricated out of 3.15 mm thick CRCA sheet dust and vermin proof powdercoated double door type(independent cabin including locking arrangementforeach MCCBs and provide space spreader for all MCCBs, bus bar chamber (enclosed) including locking arrangement complete suitable for operating on 415 Volt50 Hz AC, supply internally wired with copper conductor , TPN bus bar of aluminium strip (4 Nos) insulated by heat shrinkable sleaves & clips on shrouds for joints busbar shall be designed to withstand a fault lavel at 415 Volts having legs 45 cms made out of 65x65x6 mm angle iron grouted on brick masonary plateform upto 30 cms .Brick masonary plateform should be 60 cms abovethe Ground Level.Comprising the following : (LT Panel No 6 near URC, FWC)(i) The panel shall be front operated with cable entry from the bottem with cable glands. (ii) Fabrication of feeder piller box to be approved by CPRI width of the panel not less than 60cms Note:- Cost for construction of plateform for panel of brick masonary work in CM 1:6 with foundationPCC 1:4:8 type D-2including plaster work ,PCC copping 1:2:4 (40 mm thick stone aggerate ) ,deemed to be included in the item rate .No extra payment will be made. 55 (Note: This panel shall be a front operated with cable entry from the bottom .The fault with standing capacity shall be 25 KA .Earth bus shall be part of the main feeder pillar.)(a) MCCB 4 pole, 160 A, 415 volt 50HZwith thermal setting 70% to 100% and rupturing capacity not less than 25 KA - 01 Nos (for Incoming) (b) MCCB 3 pole 40 A, 415 volt 50HZ with thermal setting 70% to 100% and rupturing capacity not less than 16 KA -2 Nos (for out going).(f) MCCB 3 pole 25 A, 415 volt 50HZ with thermal setting 70% to 100% and rupturing capacity not less than 16 KA - 01No (for out going).(g)MCB SPN 6 to 32 amps 240 Volt - 11 Nos (out going)(h) Digital Ammeter 0 to 200 Amp with selector switch & suitable range of CTs - 01 No.(i) Digital Voltmeter 0 to 500 V with selector switch - 01 No.(j) LEDPhase indicating lamp (Set of three)- 03 Nos (RYB) 56 Supply ,Installation ,testing & commisioning of totally enclosedfeeder piller outdoor type(IP-65) fabricated out of 3.15 mm thick CRCA sheet dust and vermin proof powdercoated double door type(independent cabin including locking arrangementforeach MCCBs and provide space spreader for all MCCBs, bus bar chamber (enclosed) including locking arrangement complete suitable for operating on 415 Volt50 Hz AC, supply internally wired with copper conductor, TPN bus bar of aluminium strip (4 Nos) insulated by heat shrinkable sleaves & clips on shrouds for joints busbar shall be designed to withstand a fault lavel at 415 Volts having legs 45 cms made out of 65x65x6 mm angle iron grouted on brick masonary plateform upto 30 cms .Brick masonary plateform should be 60 cms abovethe Ground Level.Comprising the following : (LT Panel No 7 MT Area)(i) The panel shall be front operated with cable entry from the bottem with cable glands. (ii) Fabrication of feeder piller box to be approved by CPRI width of the panel not less than 60cms Note:- Cost for construction of plateform for panel of brick masonary work in CM 1:6 with foundationPCC 1:4:8 type D-2including plaster work, PCC copping 1:2:4 (40 mm thick stone aggerate ), deemed to be included in the item rate .No extra payment will be made. 57 (Note: This panel shall be a front operated with cable entry from the bottom .The fault with standing capacity shall be 25 KA .Earth bus shall be part of the main feeder pillar.)(a) MCCB 4 pole, 100 A, 415 volt 50HZwith thermal setting 70% to 100% and rupturing capacity not less than 25 KA - 01 Nos (for Incoming) .(b) MCCB 3 pole 25 A, 415 volt 50HZ with thermal setting 70% to 100% and rupturing capacity not less than 16 KA - 03 Nos (for out going).(g)MCB SPN 6 to 32 amps 240 Volt - 05 Nos (out going)(h) Digital Ammeter 0 to 200 Amp with selector switch & suitable range of CTs - 01 No.(i) Digital Voltmeter 0 to 500 V with selector switch - 01 No.(j) LEDPhase indicating lamp (Set of three)- 03 Nos (RYB) 58 Supply ,Installation ,testing & commisioning of totally enclosedfeeder piller outdoor type(IP-65) fabricated out of 3.15 mm thick CRCA sheet dust and vermin proof powdercoated double door type(independent cabin including locking arrangementforeach MCCBs and provide space spreader for all MCCBs, bus bar chamber (enclosed) including locking arrangement complete suitable for operating on 415 Volt50 Hz AC, supply internally wired with copper conductor , TPN bus bar of aluminium strip (4 Nos) insulated by heat shrinkable sleaves & clips on shrouds for joints busbar shall be designed to withstand a fault lavel at 415 Volts having legs 45 cms made out of 65x65x6 mm angle iron grouted on brick masonary plateform upto 30 cms .Brick masonary plateform should be 60 cms abovethe Ground Level.Comprising the following : (LT Panel No 8 LIFT)(i) The panel shall be front operated with cable entry from the bottem with cable glands. (ii) Fabrication of feeder piller box to be approved by CPRI width of the panel not less than 60cms Note:- Cost for construction of plateform for panel of brick masonary work in CM 1:6 with foundationPCC 1:4:8 type D-2including plaster work ,PCC copping 1:2:4 (40 mm thick stone aggerate ) ,deemed to be included in the item rate .No extra payment will be made. 59 (Note: This panel shall be a front operated with cable entry from the bottom .The fault with standing capacity shall be 25 KA .Earth bus shall be part of the main feeder pillar.)(a) MCCB 4 pole, 100 A, 415 volt 50HZwith thermal setting 70% to 100% and rupturing capacity not less than 25 KA - 01 Nos (for Incoming) .(b) MCCB 3 pole 25 A, 415 volt 50HZ with thermal setting 70% to 100% and rupturing capacity not less than 16 KA - 03 Nos (for out going).(g)MCB SPN 6 to 32 amps 240 Volt - 05 Nos (out going)(h) Digital Ammeter 0 to 200 Amp with selector switch & suitable range of CTs - 01 No.(i) Digital Voltmeter 0 to 500 V with selector switch - 01 No.(j) LEDPhase indicating lamp (Set of three)- 03 Nos (RYB) 60 External Water supplyCutting the existing DI/CI water supply pipe line 150mm dia and inserting Tee 150x150x150 mm all as specified. 61 Supply and lay pipe ductile Iron (Conforming to IS-8329-2000) with spigot and socket ends of bore 150 mm(6) diaspecial Class “K-9” including jointing material/joints laid in trenches complete all as specified 62 M & L for Construction of brick masonry valve chamber of internal dimensions 900 x 900 x 900 mm, bottom floor of the pit shall be constructed in PCC (1:3:6) 15 cm thick with 20 mm stone aggregate, inner and exposed surfaces and bottom floor of the pit should be plastered in CM (1:4) 15 mm thick. The top cover of the pit shall be made out of MS sheet min 3 mm thick with angle iron frame made out of MS angle 40 mm x 40 mm x 6 mm with 02 nossteel hinges and locking arrangements duly painted with two coats of synthetic enamel paint over one coat of red oxide primer all as specified and as directed 63 Supply and fix Air release valve 50 mm dia with two air outlets and fixing up in DI water supplymains 64 LaundrySupply and install commercial type stainless steel laundry washing machine with extractorfully automatic type front openable of capacity 30 Kg/hr, 3 phase, 415 volt, 50 Hz , have door limit switch, electric interlock and emergency stop for safety & trouble free operation with following specifications:-1. INDUSTRIAL WASHER EXTRACTORFor washing cleaning and extraction Capacity -30 kg , Electrically Heated, Front loading, Heavy duty, High Spin, single motor frequency drive, Soft Mount, Suspended, Variable frequency drive & Auto reverse forforward and reverse basket rotation, Open pocket & Front display.a. Control- Fully programmable Logic Controller (PLC) with minimum 24 programs storage with minimum 6 cycle in each program, to customize the wash programes according to the type of the linen.(Display 7 Touch screen color display to visulazie the step by step working process, easy to understand the program.)b. Dispenser - 5 compartment automatic soap dispenserthrough PLC contorlled with electric operated water inlet valves, drain valves. c. Outer Drum - Made ofhigh grade Stainless steel SS-304 with 2mm thickness 65 d. Inner Drum / Basket - Made of high grade Stainless steel sheet of SS 304 grade with perforation.e. Main body /Outer Cabinet - Made of full stainless steel 304 grade front and chemical enclosure. Sides , Top & Back covers made of SSLN 1.f. Door - Made of die pressed Stainless steel AISI 304 quality, 2 mmthickness, Toughened glass window , SS door latch/handle and interlock for safetyg. Clear Door Opening - 525 mm Ø (Minimum) Front loading and unloadingh. Level Sensor - Highly sensitive auto water level sensor with PLCi. Basket Volume- 305 Ltrs. (Minimum) of minimum size of Dia 840 x 550 mm depth. j. Seal - High quality seal to be used to prevent contact of water with theBearingsk. Bearing Housing- Roller bearings of reputed brand duly packed with grease &Lubricantsl. Washing speed- 28 -36 rpm(Minimum). m. Final Extract speed - 865 RPM(Minimum)n. G-Force - 350 at Final Extract(Minimum). o. Drive Motor - 7.5 HP (5.6 KW) Motor, VFD controlled, 3 Phase, 415 V, AC,, single motor with Variable Frequency inverter drive for various speed for wash, Distribution, Low, Medium, High spin extract.P. Electric Load - 18 Kw (Maximum)q. Inverter Make:7.5 HP, 3 Phase. 66 r. All wet materials and components must be of AISI-304 Stainless steels. All Stainless steel components should be TIG welded and highly polished.t. In-built Control Panel and Motor.u. Heater -18 KW. V. Authorization system with password: Login ID & password with 3 different levels. Level 1 : Administrator Level. Level2: Supervisor Level. Level 3 : Operator Level.w. Door Lock Machine should have both manual and auto door lock. This makes the door not to open at time of operation. x . Safetry features: Electric interlock with door limit switch, unbalacing switch and emergency stop for safety & trouble free operation. y. Wedges / Lifters:Provided 4 Nos of wedges / lifter with perforation. z. Bearing Housing: SKF Heavy duty taper roller bearings, lubricated and sealed in a cast iron housing. aa. Soap Dispenser: Chemical box with 5 compartments and individual jugs made of SS 316 grade. Separate pressurized water jet for each jug to flush out liquir / solid washing agents. ab.Water Inlet :Cold water inlet dia 1 (dia 25 mm), Hot water inlet dia 1 (dia 25 mm)optional , water inlet for chemical dia 1 (dia 25 mm) Electrically operated valve. 67 ac. Water pressure :2 -4 bar.ad. Drain :Dia 3 (dia 75 MM) .ae. Electric supply:415V, 50 Hz, 3 ph + N+ E.af. Overall Dimension : 1280 W x 1400 D x 1870 H in mm. ag. Machine weight:1000 Kgs. 2. DRYING TUMBLER:-(i)Capacity – 30 kg Electrically Heated,Electrically Heated, Heavy duty, Front Loading, Cool down Feature, Auto-timed, Auto-reversible, Auto digital temperature control, Dual Motor drive, Open Pocket & Front displaya. Control- Microprocessor/PLC/Computer controlledb. Temperature - Auto digital control Controllerc. Time - Auto digital control for drying and cooling Controllerd. Inner Drum - Made of Stainless steel AISI-304 with 1.5 mm thickness of basket,CNC Perforatede. Outer Cabinet - Made of Steel sheet of 1.5 thickness, Welded structure,Finished with Powder Coatingf. Door - Made of die pressed Stainless steel AISI 304 quality, 1.5 mmthickness, Toughened glass window , SS door latch/handle and interlock for safetyg. Door Opening - 500 mm Ø (Minimum)h. Basket Volume- 295 Ltrs.(Minimum)i. Drive Motor - 0.37 Kwj. Blower Motor - 0.37 Kwk. Suction Blower- Heavy duty Centrifugal Suction Blower and dynamically balanced 68 l. Insulation - Glass wool duly packed on all sides & front of the drierto minimize the heat loss & saves energym. Lint Screen - Self cleaning lint screen of Stainless Steel AISI-304. Facility ofcleaning should be through front doorn. Electric Load - 7.5 Kw (Maximum)o. Electric supply- 415V, 3Ø, AC, 50hz.p. Air flow - Around 30 cu/mq. All wet materials and components must be of AISI-304 Stainless steelr. All Stainless steel components should be TIG welded and highly polished.s. In-built Control Panel and Motoru. Inbuild soap containers for powder & liquid products. 3.FLAT BED PRESS:- Suitable for linen like uniform, room furnishing , personal garments, Bed sheets &Pillow Covers Head & Bed Size- 1500X750mm Electrically heated, Auto-timed, Auto-temperature controlled, Double Switch operation, Built-in Suction Blower, Pneumatically controlled,a. Head - Polished Stainless steel/High quality steel with Teflon coated/Nickelplatedb. Main Body- Made of Mild Steel sheets of 1.5 mm thickness, Welded structure andfinished with powder coatingc. Blower - Heavy duty Suction Blower with powerful suction 69 d. Safety - Emergency Stop of the machine with emergency switch. Automaticstopping of the machine for Finger guard for operator safetye. Control - Push Button for raising and lowering of the head pneumaticallyf. Temperature- Digital temperature controlcontrollerg. Electric Load- 18 Kw (Maximum)h. Electric supply- 415V, 3Ø, AC, 50hz.4. VACUUM FINISHING TABLE WITH IRONAdjustable height.Table Top Size -1300mm X 800mma. Table top - Mild Steel sheet of 2.5 thickness padding with heat resistant material likeSilicon etc. Perforated flat top padded with high porosityb. Main Body - Made of Mild steel sheets/plates and finished with powder coatingc. Blower - Heavy duty Powerful suction through Centrifugal blower of 0.5hp Motor activated by spring loaded full length foot pedal working incombination with heavy duty micro switchd. Heater - In-built Thermostatically controlled stainless steel heatere. Electric Steam- Die cast sole plate, Teflon shoe and thermostatically controlled Iron heating element with moisture trap, Rubberized handlef. Electric supply- 415 V/ 3 Ph / 50 Hz/ AC/4P 70 5. AIR COMPRESSORa. The air compressor of Kirloskar/Elgi/Ingersolrand make shall be multistage stage, fullyautomatic suitable for delivering dry compressed air at pressure compatible to Ironer.b. Drive - Belt driven with pulleys, belts and belt guard.c. Motor - 2 hp. reputed E-in-C approved make. d. Electric supply- 415 V/ 3 Ph / 50 Hz/ AC/4P.6. MOBILE TABLETable top size-1200mm x 750mmThe folding table shall be specially designed for carrying rolling and folding of linen in thelaundry. The frame of the table shall be fabricated out of MS welded construction with onebottom shelf for storage. Complete with heavy duty ball bearing for swiveling wheels. Thetable top shall be of polished Stainless steel.7. WASH ROOM TROLLEYCapacity -70KgThe wash room trolley shall be fabricated out of Stainless Steel AISI-304 tubes and flats inall welded construction ground smooth & finished, supported on swiveling wheels. 71 8. SHELF TROLLEY (Finished linen)Capacity -70KgThe linen trolley shall be designed in Stainless Steel AISI-304 construction with all weldedjoints ground & smooth finished out of Stainless Steel tubes and bars and foldable front. Thetrolley shall be fitted with at least 4 Nos. AISI-304 Stainless Steel shelves(2-shelvesremovable). The base frame shall be supported on swiveling wheels.9. STORAGE RACKSize - 1200mmx460mmx1800mm4 shelves; Made of Mild Steel, Finished with Stoving paints10. SHELF FOR FINISHED GOODSSize- 1200mmx460mmx1800mm4 shelves; Made of Mild Steel, Finished with Stoving paints11. ELECTRIC DISTRIBUTION PANELCompleted with all switchgears, wiring and controls etc for distribution of power supply to various load points in the Laundry Room from single point power supply with all safety features and soft starters for machineries deemed to be included on the quoted rate. 72 Design supply, installation, testing & commissioning of 8 passenger lift, having .75m/s car speed, single speed motor suitable for 3- Ph, 415V, 50Hz electric power supply, conforming to IS-14665, suitable to serve G + 03 upper floors with AC variable voltage & variable frequency drive (VVVF drive), complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infrared sensor in full height of door & built in announcing system without hand set (04 Nos., one each in car, machine room & near ground floor landing door) complete all as specified and directedThe lift shall conform to the following technical specification.[i)Type of Lift: 8 Passenger[ii)Load Capacity: 544kg[iii)Speed: 1.5m/s with single speed motor[iv)Speed: 1.5m/s with single speed motor[v] Type of Drive: AC Variable Voltage & Variable Frequency[vi]Type of Machine: Gearless[vii] Car Size: Not less than 1.43 m² 73 [vii]Car and Landing Door at all floors: Automatic center opening with VVVF door drive, opening size not less than 800X2000mm, sliding type, fabricated by stainless steel sheet not less than 16 gauge having hairline finish (N-304)[viiii] Car Enclosure: Manufactured with stainless steel frame not less than 16 gauge with hairline finish (N304) having stainless false ceiling with hairline finish, internal lighting arrangement with LED light fittings operated on commercial supply and one LED light fitting operated on battery with invertor as emergency light complete internal ventilation system provided with concealed arial/cross flow fan with auto cut-off system and stainless steel grill/wire mesh for protection.[x] Terminal Buffers: Metal special spring/PU/Oil buffers as per manufacturer specifications. The buffing stroke should not be less than 200mm.[xi] Door Opening (Inside): Protected by centre opening stainless steel doors with hairline finish doors with clear opening of 800X2000mm[xii] Door Opening (Inside): Protected by centre opening stainless steel doors with hairline finish doors with clear opening of 800X2000mm[xiii] Car & Counter Weight Guide: Guide rails of MS T section as per OEM design; counter weight shall be as recommended by OEM[xiv] Flooring: 5mm thick Aluminium chequred plate / as per OEM design 74 [xv] Signals:[a] Combined luminous hall buttonswith LED/ LCD /VFD hall position indicators at all floors[b] LED/LCD/VFD for car position indicator of stainless steel[c] One No. of car opening panel with luminous buttons in car (stainless steel)[d] Car direction indicator in car & landing[e] Battery operated alarm bell & emergency light (rechargable) along with suitable maintenance free battery (This system should be separate from ARDbatteries.)[g] One firemans switch to be installed at ground floor near landing door[h] All signal fixture & car operating panel on hairline stainless steel face plate with hairline finish.[i] Infra red door sensor safety edge of door for entire height.[j] Built in announcing system without handset 2 Nos., one for lift car & ground floor landing door and one anouncing system with handset in machine room.[k] The interior of the car should be provided with a device that audibly announce the floor position of lift car has reached and announce that car entrance/exit door is open or closed. 75 [xv] Safety Device:[a] Automatic rescue device (ARD)/automatic landing device operating with maintenance-free batteries having suitable capacity. The batteries must have auto charging facilities. The charger input be connected with converter of regerertive drive.[b] The ARD actuation time should be less than one second after failure of power supply and when ARD is operative the car should stop at the nearest floor and then open.[xvii] Operation: Simplex, full collective automatic operation with and without attendant.[xviii] Machine room: Located above the hoist way.Details as per building drawing[xx] Civil work: Necessary Civil work viz. making good disturbed surfaces, modification to landing space to suit to car size, necessary foundation to machine etc.[xxi] One number of wall mounted type telephone instrument of make installed inside of car cabin along with fixing arrangement and telephone cable of suitable size from car cabin to machine room run along with travelling cable. The telephone instrument shall be connected in the telephone DB installed in the machine room.Provision of suitable size of copper conductor XLPE insulated cable from Lift Panel installed at Ground floor to machine room will deemed to beincluded the rate quoted by the contractor 76 Note: The schedule of credit has been attached in tender in Pdf format as Sch A Part-XIII and amount of credit schedule i.e. Rs 1972660.50 shall be deducted from the total amount of BOQ to arrive at the contract sum.