Tender For Special Repair& Maintenance Work At Jnv Arwal, Bihar. - STRUCTURE REPAIR & RETROFITTINGS 3 Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge 4 50mm average thickness 5 25 mm average thickness 6 Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. 7 Bars upto 12 mm diameter 8 Cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of Engineer in charge. 9 Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by Engineerin- Charge 10 Note: Rates shall include the providing necessary ground wires etc. The levelling gauges, if used, shall be paid for separately. Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 11 25mm thick in Grade M 25 with cement content not less than 330 kg per cum 12 50mm thick in Grade M 25 with cement content not less than 330 kg per cum 13 Expansion Joint Treatment 14 Providing and fixing of expansion joint system related with wall joint (internal/ external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints Systemsuitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall confirm to ASTM 6063). 15 Wall Joint of 100 mm gap 16 Providing and fixing of expansion joint system of approved make and manufacture for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates as per ASTM B221-02. The system shall be such that it provides water tight roof to roof /roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates a universal aluminum base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall confirm to ASTM 6063.) 17 Roof Joint of 100 mm gap 18 REPAIRS TO ROOF 19 Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 3 mm thick 20 Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation. 21 Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 22 REPAIRS TO TOILETS 23 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 24 For thickness of tiles 10 mm to 25 mm 25 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 26 Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 27 75 to 80 mm dia pipe 28 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 29 110 mm diameter 30 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 31 a) Coupler 32 110 mm 33 b) Bend 87.5° 34 110 mm bend 35 Providing & fixing C.P. Brass Waste Coupling for PVC waste Pipe. 36 Providing & fixing UPVC Floor trap of self cleansing designwith stainless steel grating complete in all respects. 37 Multi Floor Trap (5 Ht) with height raiser and branch saddle strip of 50/75 mm outlet 38 Plain Floor Trap (4 Ht) with 50 / 75 outlet and with height raiser 39 P-Trap type Floor Trap 110 x 75 mm 40 Extra for providing & fixing 125 mm dia C.P. grating in place of C.I. grating over floor traps. 41 Providing & fixing of SS Floor Cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 42 Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : 43 Size 450x300x150 mm 44 Providing and fixing P.V.C. waste pipe for sinkor wash basin including P.V.C. waste fittings complete. 45 Flexible pipe 46 40 mm dia 47 Providing and fixing 100 mm sand cast Iron grating for gully trap. 48 Providing & fixing soil, waste and vent pipes. 49 a) 100mm dia centrifugally cast iron S & S pipe. 50 b)75mm dia centrifugally cast iron S & S pipe. 51 Providing & fixing M.S. holder bat clamps of approved design to sand cast iron/centrifugally cast (Spun) iron S & S pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).Including cost of cutting holes & making good the walls etc. 52 a) for 100mm dia pipe. 53 b) for 75mm dia pipe. 54 Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 55 a) 100mm 56 Sand cast iron S&S as per IS - 3989 57 b) 75mm 58 Sand cast iron S&S as per IS- 3989 59 Providing and fixing plaincast iron S & S sanitary bend. 60 a) 100mm 61 Sand cast iron S&S as per IS - 1729 62 b) 75mm 63 Sand cast iron S&S as per IS - 3989 64 Providing and fixing centrifugaly cast iron single equal plain junction of required degree. 65 a) 100x100x100mm 66 b) 75x75x75mm 67 Providing and fixingcast iron terminal guard. 68 a) 100mm 69 b) 75mm 70 Providing & fixingcast iron coller. 71 a)100 mm 72 Sand cast iron S&S as per IS - 3989 73 b)75mm dia. 74 Sand cast iron S&S as per IS - 3989 75 Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 76 a) 100mm 77 b) 75mm 78 Providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 79 a) 100mm inlet & 75mm outlet. 80 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 81 15 mm nominal outer dia Pipes 82 20 mm nominal outer dia Pipes 83 25 mm nominal outer dia Pipes 84 32 mm nominal outer dia Pipes 85 Providing and fixing brass stop cock of approved quality. 86 15 mm nominal bore 87 Providing and fixing gun metal gate valve with wheel of approved quality. 88 a) 25mm dia nominal bore 89 b) 32mm dia nominal bore 90 Providing and fixing ball valve (brass) of approved quality complete.(High or low pressure with plastic floats). 91 a) 25mm. Nominal bore 92 Providing and fixing 30 cm long unplasticised PVC connection pipe with brass unions. 93 a) 15mm nominal bore 94 Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions. 95 a) 15mm nominal bore 96 Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation 3concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 97 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 98 Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 99 a) 15mm nominal bore 100 Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 101 a) 15mm nominal bore 102 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 103 15mm nominal bore 104 Cutting holes up to 30x30 cm in walls including making good the same: 105 With common burnt clay F.P.S. (non modular) bricks 106 Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 107 Making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc. 108 Raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (Raising depth of manhole to be paid separately) : 109 Rectangular manhole 90x80 cm with rectangular cover600 x 450 mm of grade LD - 2.5 110 Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre) (if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) 111 REPAIR TO PLASTER & PLINTH PROTECTION 112 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 113 Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of Engineer-In-Charge. 114 With cement mortar 1:4 (1cement: 4 coarse sand) 115 Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete 116 15mm cement plaster on rough side of single or half brick wall of mix 117 1:6 (1 cement : 6 course sand) 118 6mm cement plaster to ceiling of mix : 119 1:3 ( 1 cement : 3 fine sand) 120 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 121 Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. 122 Two coats 123 Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 13.81.1 Old work (one or more coats) 124 Old work (one or more coats) 125 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: 126 New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 127 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade 128 Old work (Two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface 129 Washed stone grit plaster on exterior walls height upto 10 metre above ground level, in two layers, under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand ), furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 2 Kg of cement per square metre, top layer 15 mm cement plaster 1:1/ 2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10 mm nominal size), in panels with groove all around as per approved pattern, including scrubbing and washing the top layer with brushes and water to expose the stone chippings ,complete as per specification and direction of Engineer-in-charge (payment for providing grooves shall be made separately). 130 Forming groove of uniform size in the top layer of washed stone gritplaster as per approved pattern using wooden battens, nailed to theunder layer, including removal of wooden battens, repair to the edgesof panels and finishing the groove complete as per specificationsand direction of the Engineer-in-charge : 131 15 mm wide and 15 mm deep groove 132 REPAIRS TO DOOR/WINDOWS 133 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 134 Of area 3 sq. metres and below 135 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 136 Of area 3 sq. metres and below 137 Renewing glass panes, with putty and nails wherever necessaryincluding racking out the old putty: 138 Float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 139 Renewal of old putty of glass panes (length) 140 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 141 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 142 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 143 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coatwith approved steel primer all complete .Fixed to steel windows by welding 144 Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete 145 300 mm weighing not less than 330 grams 146 250 mm weighing not less than 280 grams 147 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 148 100X58X1.90 mm 149 Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 150 Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 151 300 x 10mm 152 150 x 10mm 153 Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. 154 Twin rubber stopper 155 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 156 125 mm 157 Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer 158 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 159 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm allcomplete. 160 With 12 mm mild steel U beading 161 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 162 Fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 163 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 164 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 165 Providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 166 4.0 mm thick glass panes 167 Applying priming coat : 168 With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood 169 With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 170 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 171 Two or more coats on new work 172 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 173 One or more coats on old work 174 MISCELLANEOUS 175 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 176 In cement mortar 177 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : 178 Cement mortar 1:6 (1 cement : 6 coarse sand) 179 Half brick masonry with common burnt clay F.P.S. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor V level. 180 Cement mortar 1:4 (1 cement :4 coarse sand 181 Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry. 182 [SCHOOL BUILDING LABS] 183 Reinforced Cement Concrete 184 Centering and shuttering including strutting, propping etc. and removal of form for all heights : 185 Suspended floors, roofs, landings, balconies and access platform. 186 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500 D or more. 187 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately). 188 Above plinth to floor-V lvl 189 R.C.C. work in Slab 190 Masonry Work 191 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand) 192 Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. 193 Cladding Work 194 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 195 Area of slab upto 0.50 sqm 196 Area of slab over 0.50 sqm 197 Providing edge moulding to 18mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. 198 Granite work 199 Extra for fixing marble /granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete. 200 Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 201 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 202 Flooring 203 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 204 Nominal concrete 1:3:6 or richer mix (i/c equivalentdesign mix) 205 Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge.In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) Acid and alkali resistant tile. 206 Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge.In dado/skirting on 12 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) Acid and alkali resistant tile. 207 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. (a) Size of Tile 600x600 mm 208 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % andonforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm 209 Finishing 210 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 coarse sand) 211 6 mm cement plaster on celling (a) 1:3(1 cement:3 fine sand) 212 ELECTRICAL WORK OF SCHOOL BUILDING 213 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. 214 Group C 215 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 216 Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. 217 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 218 2X1.5 sq. mm + 1 X 1.5 sq. mm earth wire 219 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 220 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 221 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable and 1.5 sq.mm. FR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 222 Group C 223 Rewiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. 224 Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 225 2 x 1.5 sq. mm 226 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 227 25 mm 228 32 mm 229 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 230 100 mm X 100 mm X 60 mm deep 231 150 mm X 75 mm X 60 mm deep 232 Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings). 233 Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 234 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 235 Supplying and fixing brass batten/ angle holder including connection etc. as required. 236 Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 237 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 238 4 way (4 + 12), Double door 239 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 240 Single pole 241 Single pole and neutral 242 Triple pole 243 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 244 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 245 Earthing with G.I. earth pipe 4.5 Mtr long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 246 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Mtr long etc. with charcoal/ coke and salt as required. 247 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 248 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 249 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 250 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 251 Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. 252 Supply of 15W SURFACE MOUNTED ROUND LED with all accessories as per standard item.. 253 Supply of 20W SURFACE MOUNTED ROUND LED with all accessories as per standard item..(Such as Panasonic ADL04R206 or Equivalent). 254 Supply of 15W WALL BRACKET LED BULB with all accessories as per standard item..(Such as Panasonic PBUM01157 or Equivalent). 255 Supply of 20W SURFACE MOUNTED LED TUBE with all accessories as per standard item..(Such as Panasonic PBTM01207 or Equivalent). 256 COST OF KITCHEN & DINNING 257 Structural Repair & Retrofitting 258 Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge 259 50mm average thickness 260 Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. 261 Bars upto 12 mm diameter 262 Cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of Engineer in charge. 263 Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by Engineerin- Charge 264 Note: Rates shall include the providing necessary ground wires etc. The levelling gauges, if used, shall be paid for separately. Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 265 50mm thick in Grade M 25 with cement content not less than 330 kg per cum 266 Repairs to Roof 267 Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 3 mm thick 268 Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation. 269 Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 270 Repairs to plaster of thickness 12 mm to 20 mm in patches with epoxy based dampgaurd (Dr. Fixit Make), including cutting the area of plaster in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.With cement mortar 1:4 (1cement: 4 coarse sand) 271 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Electric resistance or induction butt welded tubes. 272 Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete 0.80 mm thick with zinc coating not less than 275 gm/m² 273 Providing and fixing 15 cm wide, 45 cm overall semi-circular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete. 0.80 mm thick with zinc coating not less than 275 gm/m² 274 Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 1.00 mm thick with zinc coating not less than 275 gm/m* 275 Repair to Toilets 276 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 277 For thickness of tiles 10 mm to 25 mm 278 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 279 Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 280 75 to 80 mm dia pipe 281 Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : 282 15 mm to 40 mm nominal bore 283 Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of Engineer-in-charge: 284 Up to 150 mm diameter 285 Taking out C.I. cover with frame from R.C.C. top slab of manholes of various sizes including demolishing of R.C.C. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of Engineer-in-charge. 286 Dismantling of road gully chamber of various sizes including C.I. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 287 Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in- Charge. 288 Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. 289 Dismantling of C.I. sluice valve including stacking of useful materials within a lead of 50 metres 290 Up to 150 mm diameter 291 Dismantling of manhole including R.C.C. top slab, C.I. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of Engineer- charge : 292 Rectangular manhole 90x80 cm and 45 cm deep 293 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 294 110 mm diameter 295 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 296 a) Coupler 297 110 mm 298 b) Bend 87.5° 299 110 mm bend 300 Painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 301 75 mm diameter pipes 302 100 mm diameter pipes 303 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 304 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 305 Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mmC.P. brass waste of standard pattern including cutting & making good the walls wherever required. 306 a)Flat back wash Basin size 550x400 mm with single 15mm C.P. brass pillar tap. 307 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 308 Kitchen sink without drain board 309 610x510 mm bowl depth 200 mm 310 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. 311 a) 32mm dia (for wash basin) 312 b) 40mm dia (for sink and urinal) 313 Providing & fixing C.P. Brass Waste Coupling for PVC waste Pipe. 314 Providing, fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipesfor soil, waste, and vent, Type-B as per IS : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without doors),reducers, WC connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. The rubber ring shall confirm to IS:5382.The Pipes will be supported with threaded G I rods & U clamps with nuts, washers etc on 50x50x5 mm slotted angle. The cost will include all support arrangements. The work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 315 110 mm dia (Wall Thickness - 3.2 to 3.8 mm) 316 75 mm dia (Wall Thickness - 3.2 to 3.8 mm) 317 Providing & fixing UPVC Floor trap of self cleansing designwith stainless steel grating complete in all respects. 318 Multi Floor Trap (5 Ht) with height raiser and branch saddle strip of 50/75 mm outlet 319 Plain Floor Trap (4 Ht) with 50 / 75 outlet and with height raiser 320 P-Trap type Floor Trap 110 x 75 mm 321 Extra for providing & fixing 125 mm dia C.P. grating in place of C.I. grating over floor traps. 322 Providing & fixing of SS Floor Cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 323 Providing and fixing 100 mm sand cast Iron grating for gully trap. 324 Providing & fixing soil, waste and vent pipes. 325 a) 100mm dia centrifugally cast iron S & S pipe. 326 b)75mm dia centrifugally cast iron S & S pipe. 327 Providing & fixing M.S. holder bat clamps of approved design to sand cast iron/centrifugally cast (Spun) iron S & S pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).Including cost of cutting holes & making good the walls etc. 328 a) for 100mm dia pipe. 329 b) for 75mm dia pipe. 330 Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 331 a) 100mm 332 Sand cast iron S&S as per IS - 3989 333 b) 75mm 334 Sand cast iron S&S as per IS- 3989 335 Providing and fixing plaincast iron S & S sanitary bend. 336 a) 100mm 337 Sand cast iron S&S as per IS - 1729 338 b) 75mm 339 Sand cast iron S&S as per IS - 3989 340 Providing and fixing centrifugaly cast iron single equal plain junction of required degree. 341 a) 100x100x100mm 342 b) 75x75x75mm 343 Providing and fixingcast iron terminal guard. 344 a) 100mm 345 b) 75mm 346 Providing & fixingcast iron coller. 347 a)100 mm 348 Sand cast iron S&S as per IS - 3989 349 b)75mm dia. 350 Sand cast iron S&S as per IS - 3989 351 Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 352 a) 100mm 353 b) 75mm 354 Providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 355 a) 100mm inlet & 75mm outlet. 356 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 357 15 mm nominal outer dia Pipes 358 20 mm nominal outer dia Pipes 359 25 mm nominal outer dia Pipes 360 32 mm nominal outer dia Pipes 361 Providing and fixing brass stop cock of approved quality. 362 15 mm nominal bore 363 Providing and fixing gun metal gate valve with wheel of approved quality. 364 a) 25mm dia nominal bore 365 b) 32mm dia nominal bore 366 Providing and fixing ball valve (brass) of approved quality complete.(High or low pressure with plastic floats). 367 a) 25mm. Nominal bore 368 Providing and fixing 30 cm long unplasticised PVC connection pipe with brass unions. 369 a) 15mm nominal bore 370 Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions. 371 a) 15mm nominal bore 372 Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation 3concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 373 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 374 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 375 With common burnt clay F.P.S.(non modular) bricks ofclass designation 7.5 376 Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 377 a) 15mm nominal bore 378 Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 379 a) 15mm nominal bore 380 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 381 15mm nominal bore 382 Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. 383 Cutting holes up to 30x30 cm in walls including making good the same: 384 With common burnt clay F.P.S. (non modular) bricks 385 Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 386 Making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc. 387 Raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (Raising depth of manhole to be paid separately) : 388 Rectangular manhole 90x80 cm with rectangular cover600 x 450 mm of grade LD - 2.5 389 Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre) (if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) 390 Repair to Plaster and Plinth Protection 391 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 392 Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 393 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 394 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 395 Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of Engineer-In-Charge. 396 With cement mortar 1:4 (1cement: 4 coarse sand) 397 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 398 15mm cement plaster on rough side of single or half brick wall of mix 399 1:6 (1 cement : 6 course sand) 400 6mm cement plaster to ceiling of mix : 401 1:3 ( 1 cement : 3 fine sand) 402 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 403 Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. 404 Two coats 405 Distempering with 1st quality acrylic distemper (ready made) having VOC content less than 50 gm per ltr. of approved manufacturer and of required shade and colour complete. as per manufacturers specification. 406 One or more coats on old work 407 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: 408 New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 409 Washed stone grit plaster on exterior walls height upto 10 metre above ground level, in two layers, under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand ), furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 2 Kg of cement per square metre, top layer 15 mm cement plaster 1:1/ 2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10 mm nominal size), in panels with groove all around as per approved pattern, including scrubbing and washing the top layer with brushes and water to expose the stone chippings ,complete as per specification and direction of Engineer-in-charge (payment for providing grooves shall be made separately). 410 Forming groove of uniform size in the top layer of washed stone gritplaster as per approved pattern using wooden battens, nailed to theunder layer, including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge : 411 15 mm wide and 15 mm deep groove 412 Repairs to Door / Windows 413 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 414 Of area 3 sq. metres and below 415 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 416 Of area 3 sq. metres and below 417 Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: 418 Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) 419 Renewal of old putty of glass panes (length) 420 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 421 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 422 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 423 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coatwith approved steel primer all complete 424 Fixed to steel windows by welding 425 Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete 426 300 mm weighing not less than 200gms. 427 250 mm weighing not less than 150gms. 428 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 429 100X58X1.90 mm 430 Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 431 Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 432 300 x 10mm 433 200 x 10mm 434 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 435 125 mm 436 Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. 437 Twin rubber stopper 438 Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. 439 30 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) /Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS: 14856, complete as per direction of Engineer-in-charge. 440 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. 441 With 12 mm mild steel U beading 442 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. 443 Using flats 30x6mm for diagonal braces and central cross piece 444 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 445 Fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 446 Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer 447 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 448 Providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 449 4.0 mm thick glass panes 450 Applying priming coat : 451 With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood 452 With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 453 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : 454 Two or more coats on new work 455 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 456 One or more coats on old work 457 Miscellaneous 458 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 459 In cement mortar 460 Providing and fixing 16 mm M.S. Fan clamps of standard shape and size in existing R.C.C. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 461 ELECTRICAL WORK OF KITCHEN & DINING 462 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. 463 Group C 464 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 465 Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. 466 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 467 2X1.5 sq. mm + 1 X 1.5 sq. mm earth wire 468 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 469 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 470 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable and 1.5 sq.mm. FR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 471 Group C 472 Rewiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. 473 Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 474 2 x 1.5 sq. mm 475 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 476 25 mm 477 32 mm 478 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 479 100 mm X 100 mm X 60 mm deep 480 150 mm X 75 mm X 60 mm deep 481 Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 482 Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings). 483 Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 484 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 485 Supplying and fixing brass batten/ angle holder including connection etc. as required. 486 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 487 6 way, Double door 488 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 489 4 way (4 + 12), Double door 490 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 491 Single pole 492 Single pole and neutral 493 Triple pole 494 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 495 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 496 Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. 497 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 498 Upto 450 mm sweep 499 Supply of 15W SURFACE MOUNTED ROUND LED with all accessories as per standard item.. 500 Supply of 20W SURFACE MOUNTED ROUND LED with all accessories as per standard item..(Such as Panasonic ADL04R206 or Equivalent). 501 Supply of 15W WALL BRACKET LED BULB with all accessories as per standard item..(Such as Panasonic PBUM01157 or Equivalent). 502 Supply of 20W SURFACE MOUNTED LED TUBE with all accessories as per standard item..(Such as Panasonic PBTM01207 or Equivalent). 503 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 504 Supplyof AC230/250 volts, 50 HZ exhaust fansincluding providingnuts, bolts, mounting FRLSame and other accessories etc.complete 505 450 mm sweep 1400 rpm 506 BOYSDORMITORY (G) FOR 96 STUDENTS 507 Structural Repair & Retrofitting 508 Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge 509 50 mm average thickness 510 25 mm average thickness 511 Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. 512 Bars upto 12 mm diameter 513 Cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of Engineer in charge. 514 Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by Engineerin- Charge 515 Note: Rates shall include the providing necessary ground wires etc. The levelling gauges, if used, shall be paid for separately. Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 516 25mm thick in Grade M 25 with cement content not less than 330 kg per cum 517 50mm thick in Grade M 25 with cement content not less than 330 kg per cum 518 Re-Baring of MS bar 10 mm dia with Fisher Chemical including drilling of hole, cleaning, and fixing of bar complete as per direction of Engineer-in-Charge. 519 Expansion Joint Treatment 520 Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical localtion in load application areas that accommodates multi directional seismic movement without stress to its components. System shall consist of metal profiles with a universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self- centering arrangement that freely rotates / moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in- Charge. (Material shall confirm to ASTM 6063). 521 Floor Joint of 100 mm gap 522 Providing and fixing of expansion joint system related with wall joint (internal/ external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints Systemsuitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall confirm to ASTM 6063). 523 Wall Joint of 100 mm gap 524 Providing and fixing of expansion joint system of approved make and manufacture for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates as per ASTM B221-02. The system shall be such that it provides water tight roof to roof /roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates a universal aluminum base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall confirm to ASTM 6063.) 525 Roof Joint of 100 mm gap 526 Repairs to Roof 527 Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 3 mm thick 528 Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation. 529 Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 530 Repair to Toilets 531 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 532 Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) 533 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 534 For thickness of tiles 10 mm to 25 mm 535 Providing and fixing Ist quality Glazed vitrified tiles polished finish of size 600 x 600 mm tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 536 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of size of Tile 600 x 600 mm 537 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 538 Providing and filling of cinder in sunken portions. 539 Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 540 75 to 80 mm dia pipe 541 Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : 542 15 mm to 40 mm nominal bore 543 Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of Engineer-in-charge: 544 Up to 150 mm diameter 545 Taking out C.I. cover with frame from R.C.C. top slab of manholes of various sizes including demolishing of R.C.C. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of Engineer-in-charge. 546 Dismantling of road gully chamber of various sizes including C.I. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 547 Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in- Charge. 548 Dismantling of C.I. sluice valve including stacking of useful materials within a lead of 50 metres 549 Up to 150 mm diameter 550 Dismantling of manhole including R.C.C. top slab, C.I. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of Engineer- charge : 551 Rectangular manhole 90x80 cm and 45 cm deep 552 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 553 110 mm diameter 554 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 555 a) Coupler 556 110 mm 557 b) Bend 87.5° 558 110 mm bend 559 Painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 560 75 mm diameter pipes 561 100 mm diameter pipes 562 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 563 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 564 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. 565 W.C. pan with ISI marked white solid plastic seat and lid 566 Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mmC.P. brass waste of standard pattern including cutting & making good the walls wherever required. 567 a)Flat back wash Basin size 550x400 mm with single 15mm C.P. brass pillar tap. 568 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. 569 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. 570 a) 32mm dia (for wash basin) 571 b) 40mm dia (for sink and urinal) 572 Providing & fixing C.P. Brass health faucet for ablution with 1 meter long PVC tube, hand shower, couplings, wall hook and other accessories. 573 Providing & fixing C.P. Brass Waste Coupling for PVC waste Pipe. 574 Providing, fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipesfor soil, waste, and vent, Type-B as per IS : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without doors),reducers, WC connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. The rubber ring shall confirm to IS:5382.The Pipes will be supported with threaded G I rods & U clamps with nuts, washers etc on 50x50x5 mm slotted angle. The cost will include all support arrangements. The work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 575 110 mm dia (Wall Thickness - 3.2 to 3.8 mm) 576 75 mm dia (Wall Thickness - 3.2 to 3.8 mm) 577 Providing & fixing UPVC Floor trap of self cleansing designwith stainless steel grating complete in all respects. 578 Multi Floor Trap (5 Ht) with height raiser and branch saddle strip of 50/75 mm outlet 579 Plain Floor Trap (4 Ht) with 50 / 75 outlet and with height raiser 580 P-Trap type Floor Trap 110 x 75 mm 581 Extra for providing & fixing 125 mm dia C.P. grating in place of C.I. grating over floor traps. 582 Providing & fixing of SS Floor Cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 583 Providing and fixing 100 mm sand cast Iron grating for gully trap. 584 Providing & fixing soil, waste and vent pipes. 585 a) 100mm dia centrifugally cast iron S & S pipe. 586 b)75mm dia centrifugally cast iron S & S pipe. 587 Providing & fixing M.S. holder bat clamps of approved design to sand cast iron/centrifugally cast (Spun) iron S & S pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).Including cost of cutting holes & making good the walls etc. 588 a) for 100mm dia pipe. 589 b) for 75mm dia pipe. 590 Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 591 a) 100mm 592 Sand cast iron S&S as per IS - 3989 593 b) 75mm 594 Sand cast iron S&S as per IS- 3989 595 Providing and fixing plaincast iron S & S sanitary bend. 596 a) 100mm 597 Sand cast iron S&S as per IS - 1729 598 b) 75mm 599 Sand cast iron S&S as per IS - 3989 600 Providing and fixing centrifugaly cast iron single equal plain junction of required degree. 601 a) 100x100x100mm 602 b) 75x75x75mm 603 Providing and fixingcast iron terminal guard. 604 a) 100mm 605 b) 75mm 606 Providing & fixingcast iron coller. 607 a)100 mm 608 Sand cast iron S&S as per IS - 3989 609 b)75mm dia. 610 Sand cast iron S&S as per IS - 3989 611 Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 612 a) 100mm 613 b) 75mm 614 Providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 615 a) 100mm inlet & 75mm outlet. 616 Providing and fixing PTMT 15 mm Urinal spreader size 95x69x100 mm with 1/2 BSP thread and shapes, weighing not less than 60 gms. 617 Providing and fixing PTMT urinal cock of approved quality and colour. 618 15 mm nominal bore, 80 mm long, 42 mm high and 30mm wide with BSP female threads weighing not less than 48 gms 619 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 620 15 mm nominal outer dia Pipes 621 20 mm nominal outer dia Pipes 622 25 mm nominal outer dia Pipes 623 32 mm nominal outer dia Pipes 624 Providing and fixing brass stop cock of approved quality. 625 15 mm nominal bore 626 Providing and fixing gun metal gate valve with wheel of approved quality. 627 a) 25mm dia nominal bore 628 b) 32mm dia nominal bore 629 Providing and fixing ball valve (brass) of approved quality complete.(High or low pressure with plastic floats). 630 a) 25mm. Nominal bore 631 Providing and fixing 30 cm long unplasticised PVC connection pipe with brass unions. 632 a) 15mm nominal bore 633 Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions. 634 a) 15mm nominal bore 635 Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 636 a) 15mm nominal bore 637 Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 638 a) 15mm nominal bore 639 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 640 15mm nominal bore 641 Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. 642 Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 643 25mm nominal bore, weighing not less than 62 gms 644 Cutting holes up to 30x30 cm in walls including making good the same: 645 With common burnt clay F.P.S. (non modular) bricks 646 Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 647 Making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc. 648 Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre) (if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) 649 Repair to Plaster and Plinth Protection 650 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 651 Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 652 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 653 Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of Engineer-In-Charge. 654 With cement mortar 1:4 (1cement: 4 coarse sand) 655 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 656 15mm cement plaster on rough side of single or half brick wall of mix 657 1:6 (1 cement : 6 course sand) 658 6mm cement plaster to ceiling of mix : 659 1:3 ( 1 cement : 3 fine sand) 660 Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. 661 Two coats 662 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: 663 New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 664 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 665 Washed stone grit plaster on exterior walls height upto 10 metre above ground level, in two layers, under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand ), furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 2 Kg of cement per square metre, top layer 15 mm cement plaster 1:1/ 2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10 mm nominal size), in panels with groove all around as per approved pattern, including scrubbing and washing the top layer with brushes and water to expose the stone chippings ,complete as per specification and direction of Engineer-in-charge (payment for providing grooves shall be made separately). 666 Forming groove of uniform size in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer, including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge : 667 15 mm wide and 15 mm deep groove 668 Repairs to Door / Windows 669 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 670 Of area 3 sq. metres and below 671 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 672 Of area 3 sq. metres and below 673 Renewing glass panes, with putty and nails wherever necessaryincluding racking out the old putty: 674 Float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 675 Renewal of old putty of glass panes (length) 676 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 677 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 678 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 679 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coatwith approved steel primer all complete .Fixed to steel windows by welding 680 Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete 681 300 mm weighing not less than 200gms. 682 250 mm weighing not less than 150gms. 683 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 684 100X58X1.90 mm 685 Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 686 Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 687 300 x 10mm 688 150 x 10mm 689 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 690 125 mm 691 Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. 692 Twin rubber stopper 693 Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. 694 Providing and fixing to existing door frames. 695 30 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam PUF)/ Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS: 14856, complete as per direction of Engineer-in-charge. 696 Providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4mm in both directions for doors, windows and clerestory windows with necessary screws : 697 35 mm thick shutters.With ISI marked stainless steel butt hinges of required size. Kiln seasoned and chemically treated hollock wood. 698 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm allcomplete. 699 With 12 mm mild steel U beading 700 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. 701 Using flats 30x6mm for diagonal braces and central cross piece 702 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 703 Fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 704 Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer 705 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 706 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 707 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 708 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 709 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 710 Providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 711 4.0 mm thick glass panes 712 Applying priming coat : 713 With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood 714 With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 715 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 716 Two or more coats on new work 717 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 718 One or more coats on old work 719 Miscellaneous 720 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 721 In cement mortar 722 Providing and fixing 16 mm M.S. Fan clamps of standard shape and size in existing R.C.C. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 723 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : 724 Cement mortar 1:6 (1 cement : 6 coarse sand) 725 Half brick masonry with common burnt clay F.P.S. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor V level. 726 Cement mortar 1:4 (1 cement :4 coarse sand 727 Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry. 728 ELECTRICAL WORK OF BOYSDORMITORY (G) FOR 96 STUDENTS 729 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. 730 Group B 731 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 732 Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. 733 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 734 2X1.5 sq. mm + 1 X 1.5 sq. mm earth wire 735 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 736 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 737 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable and 1.5 sq.mm. FR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 738 Group B 739 Rewiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. 740 Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 741 2 x 1.5 sq. mm 742 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 743 25 mm 744 32 mm 745 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 746 100 mm X 100 mm X 60 mm deep 747 150 mm X 75 mm X 60 mm deep 748 Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 749 Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings). 750 Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 751 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 752 Supplying and fixing brass batten/ angle holder including connection etc. as required. 753 Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 754 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 755 6 way, Double door 756 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 757 4 way (4 + 12), Double door 758 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 759 Single pole 760 Single pole and neutral 761 Triple pole 762 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 763 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 764 Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. 765 Supply of 15W SURFACE MOUNTED ROUND LED with all accessories as per standard item.. 766 Supply of 20W SURFACE MOUNTED ROUND LED with all accessories as per standard item..(Such as Panasonic ADL04R206 or Equivalent). 767 Supply of 15W WALL BRACKET LED BULB with all accessories as per standard item..(Such as Panasonic PBUM01157 or Equivalent). 768 Supply of 20W SURFACE MOUNTED LED TUBE with all accessories as per standard item..(Such as Panasonic PBTM01207 or Equivalent). 769 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 770 COST OF GIRLS DORMITORIES (CPWD TYPE) 2 BLOCKS 771 Structural Repair & Retrofitting 772 Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge 773 50 mm average thickness 774 25 mm average thickness 775 Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. 776 Bars upto 12 mm diameter 777 Cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of Engineer in charge. 778 Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by Engineerin- Charge 779 Note: Rates shall include the providing necessary ground wires etc. The levelling gauges, if used, shall be paid for separately. Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 780 25mm thick in Grade M 25 with cement content not less than 330 kg per cum 781 50mm thick in Grade M 25 with cement content not less than 330 kg per cum 782 Re-Baring of MS bar 10 mm dia with Fisher Chemical including drilling of hole, cleaning, and fixing of bar complete as per direction of Engineer-in-Charge. 783 Expansion Joint Treatment 784 Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical localtion in load application areas that accommodates multi directional seismic movement without stress to its components. System shall consist of metal profiles with a universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self- centering arrangement that freely rotates / moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in- Charge. (Material shall confirm to ASTM 6063). 785 Floor Joint of 100 mm gap 786 Providing and fixing of expansion joint system related with wall joint (internal/ external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints Systemsuitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall confirm to ASTM 6063). 787 Wall Joint of 100 mm gap 788 Providing and fixing of expansion joint system of approved make and manufacture for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates as per ASTM B221-02. The system shall be such that it provides water tight roof to roof /roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates a universal aluminum base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall confirm to ASTM 6063.) 789 Roof Joint of 100 mm gap 790 Repairs to Roof 791 Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 3 mm thick 792 Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation. 793 Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 794 Repair to Toilets 795 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 796 Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) 797 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 798 For thickness of tiles 10 mm to 25 mm 799 Providing and fixing Ist quality Glazed vitrified tiles polished finish of size 600 x 600 mm tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 800 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of size of Tile 600 x 600 mm 801 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 802 Providing and filling of cinder in sunken portions. 803 Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 804 75 to 80 mm dia pipe 805 Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : 806 15 mm to 40 mm nominal bore 807 Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of Engineer-in-charge: 808 Up to 150 mm diameter 809 Taking out C.I. cover with frame from R.C.C. top slab of manholes of various sizes including demolishing of R.C.C. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of Engineer-in-charge. 810 Dismantling of road gully chamber of various sizes including C.I. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 811 Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in- Charge. 812 Dismantling of C.I. sluice valve including stacking of useful materials within a lead of 50 metres 813 Up to 150 mm diameter 814 Dismantling of manhole including R.C.C. top slab, C.I. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of Engineer- charge : 815 Rectangular manhole 90x80 cm and 45 cm deep 816 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 817 110 mm diameter 818 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 819 a) Coupler 820 110 mm 821 b) Bend 87.5° 822 110 mm bend 823 Painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 824 75 mm diameter pipes 825 100 mm diameter pipes 826 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 827 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 828 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. 829 W.C. pan with ISI marked white solid plastic seat and lid 830 Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mmC.P. brass waste of standard pattern including cutting & making good the walls wherever required. 831 a)Flat back wash Basin size 550x400 mm with single 15mm C.P. brass pillar tap. 832 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. 833 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. 834 a) 32mm dia (for wash basin) 835 b) 40mm dia (for sink and urinal) 836 Providing & fixing C.P. Brass health faucet for ablution with 1 meter long PVC tube, hand shower, couplings, wall hook and other accessories. 837 Providing & fixing C.P. Brass Waste Coupling for PVC waste Pipe. 838 Providing, fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipesfor soil, waste, and vent, Type-B as per IS : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without doors),reducers, WC connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. The rubber ring shall confirm to IS:5382.The Pipes will be supported with threaded G I rods & U clamps with nuts, washers etc on 50x50x5 mm slotted angle. The cost will include all support arrangements. The work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 839 110 mm dia (Wall Thickness - 3.2 to 3.8 mm) 840 75 mm dia (Wall Thickness - 3.2 to 3.8 mm) 841 Providing & fixing UPVC Floor trap of self cleansing designwith stainless steel grating complete in all respects. 842 Multi Floor Trap (5 Ht) with height raiser and branch saddle strip of 50/75 mm outlet 843 Plain Floor Trap (4 Ht) with 50 / 75 outlet and with height raiser 844 P-Trap type Floor Trap 110 x 75 mm 845 Extra for providing & fixing 125 mm dia C.P. grating in place of C.I. grating over floor traps. 846 Providing & fixing of SS Floor Cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 847 Providing and fixing 100 mm sand cast Iron grating for gully trap. 848 Providing & fixing soil, waste and vent pipes. 849 a) 100mm dia centrifugally cast iron S & S pipe. 850 b)75mm dia centrifugally cast iron S & S pipe. 851 Providing & fixing M.S. holder bat clamps of approved design to sand cast iron/centrifugally cast (Spun) iron S & S pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).Including cost of cutting holes & making good the walls etc. 852 a) for 100mm dia pipe. 853 b) for 75mm dia pipe. 854 Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 855 a) 100mm 856 Sand cast iron S&S as per IS - 3989 857 b) 75mm 858 Sand cast iron S&S as per IS- 3989 859 Providing and fixing plaincast iron S & S sanitary bend. 860 a) 100mm 861 Sand cast iron S&S as per IS - 1729 862 b) 75mm 863 Sand cast iron S&S as per IS - 3989 864 Providing and fixing centrifugaly cast iron single equal plain junction of required degree. 865 a) 100x100x100mm 866 b) 75x75x75mm 867 Providing and fixingcast iron terminal guard. 868 a) 100mm 869 b) 75mm 870 Providing & fixingcast iron coller. 871 a)100 mm 872 Sand cast iron S&S as per IS - 3989 873 b)75mm dia. 874 Sand cast iron S&S as per IS - 3989 875 Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 876 a) 100mm 877 b) 75mm 878 Providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 879 a) 100mm inlet & 75mm outlet. 880 Providing and fixing PTMT 15 mm Urinal spreader size 95x69x100 mm with 1/2 BSP thread and shapes, weighing not less than 60 gms. 881 Providing and fixing PTMT urinal cock of approved quality and colour. 882 15 mm nominal bore, 80 mm long, 42 mm high and 30mm wide with BSP female threads weighing not less than 48 gms 883 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 884 15 mm nominal outer dia Pipes 885 20 mm nominal outer dia Pipes 886 25 mm nominal outer dia Pipes 887 32 mm nominal outer dia Pipes 888 Providing and fixing brass stop cock of approved quality. 889 15 mm nominal bore 890 Providing and fixing gun metal gate valve with wheel of approved quality. 891 a) 25mm dia nominal bore 892 b) 32mm dia nominal bore 893 Providing and fixing ball valve (brass) of approved quality complete.(High or low pressure with plastic floats). 894 a) 25mm. Nominal bore 895 Providing and fixing 30 cm long unplasticised PVC connection pipe with brass unions. 896 a) 15mm nominal bore 897 Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions. 898 a) 15mm nominal bore 899 Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 900 a) 15mm nominal bore 901 Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 902 a) 15mm nominal bore 903 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 904 15mm nominal bore 905 Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. 906 Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 907 25mm nominal bore, weighing not less than 62 gms 908 Cutting holes up to 30x30 cm in walls including making good the same: 909 With common burnt clay F.P.S. (non modular) bricks 910 Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 911 Making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc. 912 Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre) (if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) 913 Repair to Plaster and Plinth Protection 914 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 915 Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 916 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 917 Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of Engineer-In-Charge. 918 With cement mortar 1:4 (1cement: 4 coarse sand) 919 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 920 15mm cement plaster on rough side of single or half brick wall of mix 921 1:6 (1 cement : 6 course sand) 922 6mm cement plaster to ceiling of mix : 923 1:3 ( 1 cement : 3 fine sand) 924 Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. 925 Two coats 926 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: 927 New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 928 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 929 Washed stone grit plaster on exterior walls height upto 10 metre above ground level, in two layers, under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand ), furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 2 Kg of cement per square metre, top layer 15 mm cement plaster 1:1/ 2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10 mm nominal size), in panels with groove all around as per approved pattern, including scrubbing and washing the top layer with brushes and water to expose the stone chippings ,complete as per specification and direction of Engineer-in-charge (payment for providing grooves shall be made separately). 930 Forming groove of uniform size in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer, including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge : 931 15 mm wide and 15 mm deep groove 932 Repairs to Door / Windows 933 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 934 Of area 3 sq. metres and below 935 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 936 Of area 3 sq. metres and below 937 Renewing glass panes, with putty and nails wherever necessaryincluding racking out the old putty: 938 Float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 939 Renewal of old putty of glass panes (length) 940 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 941 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 942 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 943 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coatwith approved steel primer all complete .Fixed to steel windows by welding 944 Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete 945 300 mm weighing not less than 200gms. 946 250 mm weighing not less than 150gms. 947 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 948 100X58X1.90 mm 949 Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 950 Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 951 300 x 10mm 952 150 x 10mm 953 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 954 125 mm 955 Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. 956 Twin rubber stopper 957 Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. 958 Providing and fixing to existing door frames. 959 30 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam PUF)/ Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS: 14856, complete as per direction of Engineer-in-charge. 960 Providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4mm in both directions for doors, windows and clerestory windows with necessary screws : 961 35 mm thick shutters.With ISI marked stainless steel butt hinges of required size. Kiln seasoned and chemically treated hollock wood. 962 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm allcomplete. 963 With 12 mm mild steel U beading 964 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. 965 Using flats 30x6mm for diagonal braces and central cross piece 966 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 967 Fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 968 Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer 969 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 970 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 971 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 972 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 973 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 974 Providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 975 4.0 mm thick glass panes 976 Applying priming coat : 977 With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood 978 With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 979 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 980 Two or more coats on new work 981 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 982 One or more coats on old work 983 Miscellaneous 984 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 985 In cement mortar 986 Providing and fixing 16 mm M.S. Fan clamps of standard shape and size in existing R.C.C. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 987 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : 988 Cement mortar 1:6 (1 cement : 6 coarse sand) 989 Half brick masonry with common burnt clay F.P.S. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor V level. 990 Cement mortar 1:4 (1 cement :4 coarse sand 991 Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry. 992 ELECTRICAL WORK OF GIRLS DORMITORY (G) FOR 96 STUDENTS 993 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. 994 Group B 995 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 996 Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. 997 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 998 2X1.5 sq. mm + 1 X 1.5 sq. mm earth wire 999 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 1000 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 1001 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable and 1.5 sq.mm. FR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 1002 Group B 1003 Rewiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. 1004 Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 1005 2 x 1.5 sq. mm 1006 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 1007 25 mm 1008 32 mm 1009 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 1010 100 mm X 100 mm X 60 mm deep 1011 150 mm X 75 mm X 60 mm deep 1012 Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 1013 Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings). 1014 Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 1015 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 1016 Supplying and fixing brass batten/ angle holder including connection etc. as required. 1017 Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 1018 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 1019 6 way, Double door 1020 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 1021 4 way (4 + 12), Double door 1022 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 1023 Single pole 1024 Single pole and neutral 1025 Triple pole 1026 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 1027 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 1028 Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. 1029 Supply of 15W SURFACE MOUNTED ROUND LED with all accessories as per standard item.. 1030 Supply of 20W SURFACE MOUNTED ROUND LED with all accessories as per standard item..(Such as Panasonic ADL04R206 or Equivalent). 1031 Supply of 15W WALL BRACKET LED BULB with all accessories as per standard item..(Such as Panasonic PBUM01157 or Equivalent). 1032 Supply of 20W SURFACE MOUNTED LED TUBE with all accessories as per standard item..(Such as Panasonic PBTM01207 or Equivalent). 1033 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 1034 Staff Qtrs Type-III . (2 blocks of four unit each) G+1 1035 Structural Repair & Retrofitting 1036 Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge 1037 50 mm average thickness 1038 25 mm average thickness 1039 Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. 1040 Bars upto 12 mm diameter 1041 Cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of Engineer in charge. 1042 Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by Engineerin- Charge 1043 Note: Rates shall include the providing necessary ground wires etc. The levelling gauges, if used, shall be paid for separately. Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 1044 25mm thick in Grade M 25 with cement content not less than 330 kg per cum 1045 50mm thick in Grade M 25 with cement content not less than 330 kg per cum 1046 Re-Baring of MS bar 10 mm dia with Fisher Chemical including drilling of hole, cleaning, and fixing of bar complete as per direction of Engineer-in-Charge. 1047 Repairs to Roof 1048 Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 3 mm thick 1049 Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation. 1050 Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 1051 Repair to Toilets 1052 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 1053 Nominal concrete 1:3:6 or richer mix (i/c equivalentdesign mix) 1054 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete. 1055 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 1056 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 1057 Providing and filling of cinder in sunken portions. 1058 Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 1059 75 to 80 mm dia pipe 1060 Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : 1061 15 mm to 40 mm nominal bore 1062 Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of Engineer-in-charge: 1063 Up to 150 mm diameter 1064 Taking out C.I. cover with frame from R.C.C. top slab of manholes of various sizes including demolishing of R.C.C. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of Engineer-in-charge. 1065 Dismantling of road gully chamber of various sizes including C.I. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 1066 Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in- Charge. 1067 Dismantling of C.I. sluice valve including stacking of useful materials within a lead of 50 metres 1068 Up to 150 mm diameter 1069 Dismantling of manhole including R.C.C. top slab, C.I. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of Engineer- charge : 1070 Rectangular manhole 90x80 cm and 45 cm deep 1071 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 1072 110 mm diameter 1073 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 1074 a) Coupler 1075 110 mm 1076 b) Bend 87.5° 1077 110 mm bend 1078 Painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 1079 75 mm diameter pipes 1080 100 mm diameter pipes 1081 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 1082 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 1083 Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mmC.P. brass waste of standard pattern including cutting & making good the walls wherever required. 1084 a)Flat back wash Basin size 550x400 mm with single 15mm C.P. brass pillar tap. 1085 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making goodthe walls wherever required : 1086 Kitchen sink without drain board 1087 610x510 mm bowl depth 200 mm 1088 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. 1089 a) 32mm dia (for wash basin) 1090 b) 40mm dia (for sink and urinal) 1091 Waste coupling 38 mm dia of 83 mm length and 77mmbreadth, weighing not less than 60 gms 1092 Providing, fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipesfor soil, waste, and vent, Type-B as per IS : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without doors),reducers, WC connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. The rubber ring shall confirm to IS:5382. 1093 The Pipes will be supported with threaded G I rods & U clamps with nuts, washers etc on 50x50x5 mm slotted angle. The cost will include all support arrangements. The work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 1094 110 mm dia (Wall Thickness - 3.2 to 3.8 mm) 1095 75 mm dia (Wall Thickness - 3.2 to 3.8 mm) 1096 Providing & fixing UPVC Floor trap of self cleansing designwith stainless steel grating complete in all respects. 1097 Multi Floor Trap (5 Ht) with height raiser and branch saddle strip of 50/75 mm outlet 1098 Plain Floor Trap (4 Ht) with 50 / 75 outlet and with height raiser 1099 P-Trap type Floor Trap 110 x 75 mm 1100 Extra for providing & fixing 125 mm dia C.P. grating in place of C.I. grating over floor traps. 1101 Providing & fixing of SS Floor Cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 1102 Providing and fixing 100 mm sand cast Iron grating for gully trap. 1103 Providing & fixing soil, waste and vent pipes. 1104 a) 100mm dia centrifugally cast iron S & S pipe. 1105 b)75mm dia centrifugally cast iron S & S pipe. 1106 Providing & fixing M.S. holder bat clamps of approved design to sand cast iron/centrifugally cast (Spun) iron S & S pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).Including cost of cutting holes & making good the walls etc. 1107 a) for 100mm dia pipe. 1108 b) for 75mm dia pipe. 1109 Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 1110 a) 100mm 1111 Sand cast iron S&S as per IS - 3989 1112 b) 75mm 1113 Sand cast iron S&S as per IS- 3989 1114 Providing and fixing plaincast iron S & S sanitary bend. 1115 a) 100mm 1116 Sand cast iron S&S as per IS - 1729 1117 b) 75mm 1118 Sand cast iron S&S as per IS - 3989 1119 Providing and fixing centrifugaly cast iron single equal plain junction of required degree. 1120 a) 100x100x100mm 1121 b) 75x75x75mm 1122 Providing and fixingcast iron terminal guard. 1123 a) 100mm 1124 b) 75mm 1125 Providing & fixingcast iron coller. 1126 a)100 mm 1127 Sand cast iron S&S as per IS - 3989 1128 b)75mm dia. 1129 Sand cast iron S&S as per IS - 3989 1130 Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 1131 a) 100mm 1132 b) 75mm 1133 Providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 1134 a) 100mm inlet & 75mm outlet. 1135 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 1136 15 mm nominal outer dia Pipes 1137 20 mm nominal outer dia Pipes 1138 25 mm nominal outer dia Pipes 1139 32 mm nominal outer dia Pipes 1140 Providing and fixing brass stop cock of approved quality. 1141 15 mm nominal bore 1142 Providing and fixing gun metal gate valve with wheel of approved quality. 1143 a) 25mm dia nominal bore 1144 b) 32mm dia nominal bore 1145 Providing and fixing ball valve (brass) of approved quality complete.(High or low pressure with plastic floats). 1146 a) 25mm. Nominal bore 1147 Providing and fixing 30 cm long unplasticised PVC connection pipe with brass unions. 1148 a) 15mm nominal bore 1149 Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions. 1150 a) 15mm nominal bore 1151 Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation 3concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 1152 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 1153 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 1154 With common burnt clay F.P.S.(non modular) bricks ofclass designation 7.5 1155 Providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 1156 Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 1157 a) 15mm nominal bore 1158 Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 1159 a) 15mm nominal bore 1160 Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931 1161 a) 15mm nominal bore 1162 Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. 1163 Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 1164 25mm nominal bore, weighing not less than 62 gms 1165 Cutting holes up to 30x30 cm in walls including making good the same: 1166 With common burnt clay F.P.S. (non modular) bricks 1167 Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 1168 Making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc. 1169 Raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (Raising depth of manhole to be paid separately) : 1170 Rectangular manhole 90x80 cm with rectangular cover600 x 450 mm of grade LD - 2.5 1171 Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre) (if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) 1172 Repair to Plaster and Plinth Protection 1173 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 1174 Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 1175 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 1176 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 1177 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 1178 Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of Engineer-In-Charge. 1179 With cement mortar 1:4 (1cement: 4 coarse sand) 1180 12mm cement plaster of mix : 1181 1:6 (1 cement : 6 course sand) 1182 6mm cement plaster to ceiling of mix : 1183 1:3 ( 1 cement : 3 fine sand) 1184 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 1185 New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 1186 Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 13.81.1 Old work (one or more coats) 1187 Old work (one or more coats) 1188 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 1189 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: 1190 New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 1191 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade 1192 Old work (Two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface 1193 Washed stone grit plaster on exterior walls height upto 10 metre above ground level, in two layers, under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand ), furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 2 Kg of cement per square metre, top layer 15 mm cement plaster 1:1/ 2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10 mm nominal size), in panels with groove all around as per approved pattern, including scrubbing and washing the top layer with brushes and water to expose the stone chippings ,complete as per specification and direction of Engineer-in-charge (payment for providing grooves shall be made separately). 1194 Forming groove of uniform size in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer, including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge : 1195 15 mm wide and 15 mm deep groove 1196 Repairs to Door / Windows 1197 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 1198 Of area 3 sq. metres and below 1199 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 1200 Of area 3 sq. metres and below 1201 Renewing glass panes, with putty and nails wherever necessaryincluding racking out the old putty: 1202 Float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 1203 Renewal of old putty of glass panes (length) 1204 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 1205 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 1206 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 1207 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coatwith approved steel primer all complete. Fixed to steel windows by welding 1208 Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete 1209 300 mm weighing not less than 200gms. 1210 250 mm weighing not less than 150gms. 1211 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 1212 100X58X1.90 mm 1213 Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 1214 Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 1215 300 x 10mm 1216 150 x 10mm 1217 Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. 1218 Providing and fixing to existing door frames. 1219 30 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam PUF)/ Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS: 14856, complete as per direction of Engineer-in-charge. 1220 Providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws. 1221 30 mm thick shutterswith ISI marked M.S. butt hinges with necessary screws 1222 With ISI marked stainless steel butt hinges of required size 1223 Kiln seasoned and chemically treated hollock wood 1224 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm allcomplete. 1225 With 12 mm mild steel U beading 1226 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 1227 125 mm 1228 Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 1229 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 1230 Fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 1231 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 1232 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 1233 Providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 1234 4.0 mm thick glass panes 1235 Applying priming coat : 1236 With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) 1237 With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 1238 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 1239 Two or more coats on new work 1240 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 1241 One or more coats on old work 1242 Flooring 1243 Miscellaneous 1244 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : 1245 Cement mortar 1:6 (1 cement : 6 coarse sand) 1246 Half brick masonry with common burnt clay F.P.S. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor V level. 1247 Cement mortar 1:4 (1 cement :4 coarse sand 1248 Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry. 1249 Providing and fixing 16 mm M.S. Fan clamps of standard shape and size in existing R.C.C. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 1250 SB- ELECTRICAL 1251 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. 1252 Group B 1253 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 1254 Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. 1255 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 1256 2X1.5 sq. mm + 1 X 1.5 sq. mm earth wire 1257 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 1258 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 1259 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable and 1.5 sq.mm. FR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 1260 Group B 1261 Rewiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. 1262 Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 1263 2 x 1.5 sq. mm 1264 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 1265 25 mm 1266 32 mm 1267 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 1268 100 mm X 100 mm X 60 mm deep 1269 150 mm X 75 mm X 60 mm deep 1270 Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 1271 Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings). 1272 Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 1273 S/F light plug point Modular type accessories :- 1274 Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess including providingandfixing 3 pin 5/6 amps modular socket outlet and 5/6 amps. modular switch, connection etc. as required. 1275 S/F power plug point modular type accessories :- 1276 Supply and fixing of suitable size GI box with modular plate and cover in FRLSont on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps. modular switch, connection etc. as required. 1277 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 1278 Supplying and fixing brass batten/ angle holder including connection etc. as required. 1279 Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 1280 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 1281 6 way, Double door 1282 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 1283 4 way (4 + 12), Double door 1284 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 1285 Single pole 1286 Single pole and neutral 1287 Triple pole 1288 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 1289 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 1290 Earthing with G.I. earth pipe 4.5 Mtr long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 1291 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 1292 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 1293 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 1294 Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. 1295 Supply of 15W SURFACE MOUNTED ROUND LED with all accessories as per standard item.. 1296 Supply of 20W SURFACE MOUNTED ROUND LED with all accessories as per standard item..(Such as Panasonic ADL04R206 or Equivalent). 1297 Supply of 15W WALL BRACKET LED BULB with all accessories as per standard item..(Such as Panasonic PBUM01157 or Equivalent). 1298 Supply of 20W SURFACE MOUNTED LED TUBE with all accessories as per standard item..(Such as Panasonic PBTM01207 or Equivalent). 1299 COST OF Staff Qtrs Type-II . (2 blocks of four unit each) G+1 1300 Structural Repair & Retrofitting 1301 Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge 1302 50 mm average thickness 1303 25 mm average thickness 1304 Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. 1305 Bars upto 12 mm diameter 1306 Cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of Engineer in charge. 1307 Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by Engineerin- Charge 1308 Note: Rates shall include the providing necessary ground wires etc. The levelling gauges, if used, shall be paid for separately. Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 1309 25mm thick in Grade M 25 with cement content not less than 330 kg per cum 1310 50mm thick in Grade M 25 with cement content not less than 330 kg per cum 1311 Re-Baring of MS bar 10 mm dia with Fisher Chemical including drilling of hole, cleaning, and fixing of bar complete as per direction of Engineer-in-Charge. 1312 Repairs to Roof 1313 Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 3 mm thick 1314 Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation. 1315 Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 1316 Repair to Toilets 1317 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 1318 Nominal concrete 1:3:6 or richer mix (i/c equivalentdesign mix) 1319 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete. 1320 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 1321 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 1322 Providing and filling of cinder in sunken portions. 1323 Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 1324 75 to 80 mm dia pipe 1325 Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : 1326 15 mm to 40 mm nominal bore 1327 Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of Engineer-in-charge: 1328 Up to 150 mm diameter 1329 Taking out C.I. cover with frame from R.C.C. top slab of manholes of various sizes including demolishing of R.C.C. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of Engineer-in-charge. 1330 Dismantling of road gully chamber of various sizes including C.I. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 1331 Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in- Charge. 1332 Dismantling of C.I. sluice valve including stacking of useful materials within a lead of 50 metres 1333 Up to 150 mm diameter 1334 Dismantling of manhole including R.C.C. top slab, C.I. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of Engineer- charge : 1335 Rectangular manhole 90x80 cm and 45 cm deep 1336 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 1337 110 mm diameter 1338 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 1339 a) Coupler 1340 110 mm 1341 b) Bend 87.5° 1342 110 mm bend 1343 Painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 1344 75 mm diameter pipes 1345 100 mm diameter pipes 1346 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 1347 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 1348 Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mmC.P. brass waste of standard pattern including cutting & making good the walls wherever required. 1349 a)Flat back wash Basin size 550x400 mm with single 15mm C.P. brass pillar tap. 1350 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making goodthe walls wherever required : 1351 Kitchen sink without drain board 1352 610x510 mm bowl depth 200 mm 1353 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. 1354 a) 32mm dia (for wash basin) 1355 b) 40mm dia (for sink and urinal) 1356 Waste coupling 38 mm dia of 83 mm length and 77mmbreadth, weighing not less than 60 gms 1357 Providing, fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipesfor soil, waste, and vent, Type-B as per IS : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without doors),reducers, WC connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. The rubber ring shall confirm to IS:5382. 1358 The Pipes will be supported with threaded G I rods & U clamps with nuts, washers etc on 50x50x5 mm slotted angle. The cost will include all support arrangements. The work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 1359 110 mm dia (Wall Thickness - 3.2 to 3.8 mm) 1360 75 mm dia (Wall Thickness - 3.2 to 3.8 mm) 1361 Providing & fixing UPVC Floor trap of self cleansing designwith stainless steel grating complete in all respects. 1362 Multi Floor Trap (5 Ht) with height raiser and branch saddle strip of 50/75 mm outlet 1363 Plain Floor Trap (4 Ht) with 50 / 75 outlet and with height raiser 1364 P-Trap type Floor Trap 110 x 75 mm 1365 Extra for providing & fixing 125 mm dia C.P. grating in place of C.I. grating over floor traps. 1366 Providing & fixing of SS Floor Cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 1367 Providing and fixing 100 mm sand cast Iron grating for gully trap. 1368 Providing & fixing soil, waste and vent pipes. 1369 a) 100mm dia centrifugally cast iron S & S pipe. 1370 b)75mm dia centrifugally cast iron S & S pipe. 1371 Providing & fixing M.S. holder bat clamps of approved design to sand cast iron/centrifugally cast (Spun) iron S & S pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).Including cost of cutting holes & making good the walls etc. 1372 a) for 100mm dia pipe. 1373 b) for 75mm dia pipe. 1374 Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 1375 a) 100mm 1376 Sand cast iron S&S as per IS - 3989 1377 b) 75mm 1378 Sand cast iron S&S as per IS- 3989 1379 Providing and fixing plaincast iron S & S sanitary bend. 1380 a) 100mm 1381 Sand cast iron S&S as per IS - 1729 1382 b) 75mm 1383 Sand cast iron S&S as per IS - 3989 1384 Providing and fixing centrifugaly cast iron single equal plain junction of required degree. 1385 a) 100x100x100mm 1386 b) 75x75x75mm 1387 Providing and fixingcast iron terminal guard. 1388 a) 100mm 1389 b) 75mm 1390 Providing & fixingcast iron coller. 1391 a)100 mm 1392 Sand cast iron S&S as per IS - 3989 1393 b)75mm dia. 1394 Sand cast iron S&S as per IS - 3989 1395 Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 1396 a) 100mm 1397 b) 75mm 1398 Providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 1399 a) 100mm inlet & 75mm outlet. 1400 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 1401 15 mm nominal outer dia Pipes 1402 20 mm nominal outer dia Pipes 1403 25 mm nominal outer dia Pipes 1404 32 mm nominal outer dia Pipes 1405 Providing and fixing brass stop cock of approved quality. 1406 15 mm nominal bore 1407 Providing and fixing gun metal gate valve with wheel of approved quality. 1408 a) 25mm dia nominal bore 1409 b) 32mm dia nominal bore 1410 Providing and fixing ball valve (brass) of approved quality complete.(High or low pressure with plastic floats). 1411 a) 25mm. Nominal bore 1412 Providing and fixing 30 cm long unplasticised PVC connection pipe with brass unions. 1413 a) 15mm nominal bore 1414 Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions. 1415 a) 15mm nominal bore 1416 Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation 3concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 1417 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 1418 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 1419 With common burnt clay F.P.S.(non modular) bricks ofclass designation 7.5 1420 Providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 1421 Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 1422 a) 15mm nominal bore 1423 Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 1424 a) 15mm nominal bore 1425 Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931 1426 a) 15mm nominal bore 1427 Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. 1428 Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 1429 25mm nominal bore, weighing not less than 62 gms 1430 Cutting holes up to 30x30 cm in walls including making good the same: 1431 With common burnt clay F.P.S. (non modular) bricks 1432 Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 1433 Making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc. 1434 Raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (Raising depth of manhole to be paid separately) : 1435 Rectangular manhole 90x80 cm with rectangular cover600 x 450 mm of grade LD - 2.5 1436 Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre) (if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) 1437 Repair to Plaster and Plinth Protection 1438 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 1439 Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 1440 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 1441 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 1442 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 1443 Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of Engineer-In-Charge. 1444 With cement mortar 1:4 (1cement: 4 coarse sand) 1445 12mm cement plaster of mix : 1446 1:6 (1 cement : 6 course sand) 1447 6mm cement plaster to ceiling of mix : 1448 1:3 ( 1 cement : 3 fine sand) 1449 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour 1450 New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 1451 Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 13.81.1 Old work (one or more coats) 1452 Old work (one or more coats) 1453 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 1454 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: 1455 New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 1456 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade 1457 Old work (Two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface 1458 Washed stone grit plaster on exterior walls height upto 10 metre above ground level, in two layers, under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand ), furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 2 Kg of cement per square metre, top layer 15 mm cement plaster 1:1/ 2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10 mm nominal size), in panels with groove all around as per approved pattern, including scrubbing and washing the top layer with brushes and water to expose the stone chippings ,complete as per specification and direction of Engineer-in-charge (payment for providing grooves shall be made separately). 1459 Forming groove of uniform size in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer, including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge : 1460 15 mm wide and 15 mm deep groove 1461 Repairs to Door / Windows 1462 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 1463 Of area 3 sq. metres and below 1464 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 1465 Of area 3 sq. metres and below 1466 Renewing glass panes, with putty and nails wherever necessaryincluding racking out the old putty: 1467 Float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 1468 Renewal of old putty of glass panes (length) 1469 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 1470 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 1471 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 1472 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coatwith approved steel primer all complete. Fixed to steel windows by welding 1473 Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete 1474 300 mm weighing not less than 200gms. 1475 250 mm weighing not less than 150gms. 1476 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 1477 100X58X1.90 mm 1478 Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 1479 Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 1480 300 x 10mm 1481 150 x 10mm 1482 Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. 1483 Providing and fixing to existing door frames. 1484 30 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam PUF)/ Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS: 14856, complete as per direction of Engineer-in-charge. 1485 Providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws. 1486 30 mm thick shutterswith ISI marked M.S. butt hinges with necessary screws 1487 With ISI marked stainless steel butt hinges of required size 1488 Kiln seasoned and chemically treated hollock wood 1489 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm allcomplete. 1490 With 12 mm mild steel U beading 1491 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 1492 125 mm 1493 Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 1494 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 1495 Fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 1496 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 1497 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 1498 Providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 1499 4.0 mm thick glass panes 1500 Applying priming coat : 1501 With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) 1502 With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 1503 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 1504 Two or more coats on new work 1505 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 1506 One or more coats on old work 1507 Miscellaneous 1508 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : 1509 Cement mortar 1:6 (1 cement : 6 coarse sand) 1510 Half brick masonry with common burnt clay F.P.S. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor V level. 1511 Cement mortar 1:4 (1 cement :4 coarse sand 1512 Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry. 1513 Providing and fixing 16 mm M.S. Fan clamps of standard shape and size in existing R.C.C. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 1514 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. 1515 Group B 1516 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 1517 Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. 1518 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 1519 2X1.5 sq. mm + 1 X 1.5 sq. mm earth wire 1520 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 1521 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 1522 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable and 1.5 sq.mm. FR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 1523 Group B 1524 Rewiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. 1525 Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 1526 2 x 1.5 sq. mm 1527 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 1528 25 mm 1529 32 mm 1530 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 1531 100 mm X 100 mm X 60 mm deep 1532 150 mm X 75 mm X 60 mm deep 1533 Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 1534 Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings). 1535 Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 1536 S/F light plug point Modular type accessories :- 1537 Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess including providingandfixing 3 pin 5/6 amps modular socket outlet and 5/6 amps. modular switch, connection etc. as required. 1538 S/F power plug point modular type accessories :- 1539 Supply and fixing of suitable size GI box with modular plate and cover in FRLSont on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps. modular switch, connection etc. as required. 1540 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 1541 Supplying and fixing brass batten/ angle holder including connection etc. as required. 1542 Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 1543 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 1544 6 way, Double door 1545 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 1546 4 way (4 + 12), Double door 1547 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 1548 Single pole 1549 Single pole and neutral 1550 Triple pole 1551 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 1552 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 1553 Earthing with G.I. earth pipe 4.5 Mtr long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 1554 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 1555 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 1556 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 1557 Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. 1558 Supply of 15W SURFACE MOUNTED ROUND LED with all accessories as per standard item.. 1559 Supply of 20W SURFACE MOUNTED ROUND LED with all accessories as per standard item..(Such as Panasonic ADL04R206 or Equivalent). 1560 Supply of 15W WALL BRACKET LED BULB with all accessories as per standard item..(Such as Panasonic PBUM01157 or Equivalent). 1561 Supply of 20W SURFACE MOUNTED LED TUBE with all accessories as per standard item..(Such as Panasonic PBTM01207 or Equivalent). 1562 COST OF TYPE- 4 1563 Structural Repair & Retrofitting 1564 Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge 1565 50 mm average thickness 1566 25 mm average thickness 1567 Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. 1568 Bars upto 12 mm diameter 1569 Cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of Engineer in charge. 1570 Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by Engineerin- Charge 1571 Note: Rates shall include the providing necessary ground wires etc. The levelling gauges, if used, shall be paid for separately. Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 1572 25mm thick in Grade M 25 with cement content not less than 330 kg per cum 1573 50mm thick in Grade M 25 with cement content not less than 330 kg per cum 1574 Re-Baring of MS bar 10 mm dia with Fisher Chemical including drilling of hole, cleaning, and fixing of bar complete as per direction of Engineer-in-Charge. 1575 Repairs to Roof 1576 Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 3 mm thick 1577 Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the samemembrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 3 mm thick 1578 Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 1579 Repair to Toilets 1580 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 1581 For thickness of tiles 10 mm to 25 mm 1582 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 1583 Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 1584 75 to 80 mm dia pipe 1585 Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : 1586 15 mm to 40 mm nominal bore 1587 Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of Engineer-in-charge: 1588 Up to 150 mm diameter 1589 Taking out C.I. cover with frame from R.C.C. top slab of manholes of various sizes including demolishing of R.C.C. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of Engineer-in-charge. 1590 Dismantling of road gully chamber of various sizes including C.I. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 1591 Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in- Charge. 1592 Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. 1593 Dismantling of C.I. sluice valve including stacking of useful materials within a lead of 50 metres 1594 Up to 150 mm diameter 1595 Dismantling of manhole including R.C.C. top slab, C.I. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of Engineer- charge : 1596 Rectangular manhole 90x80 cm and 45 cm deep 1597 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 1598 110 mm diameter 1599 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 1600 a) Coupler 1601 110 mm 1602 b) Bend 87.5° 1603 110 mm bend 1604 Painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 1605 75 mm diameter pipes 1606 100 mm diameter pipes 1607 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 1608 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 1609 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings andfixtures complete, including cutting and making good the walls and floors wherever required : 1610 W.C. pan with ISI marked white solid plastic seat and lid 1611 Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mmC.P. brass waste of standard pattern including cutting & making good the walls wherever required. 1612 a)Flat back wash Basin size 550x400 mm with single 15mm C.P. brass pillar tap. 1613 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making goodthe walls wherever required : 1614 Kitchen sink without drain board 1615 610x510 mm bowl depth 200 mm 1616 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. 1617 a) 32mm dia (for wash basin) 1618 b) 40mm dia (for sink and urinal) 1619 Providing & fixing C.P. Brass Waste Coupling for PVC waste Pipe. 1620 Providing, fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipesfor soil, waste, and vent, Type-B as per IS : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without doors),reducers, WC connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. The rubber ring shall confirm to IS:5382. 1621 The Pipes will be supported with threaded G I rods & U clamps with nuts, washers etc on 50x50x5 mm slotted angle. The cost will include all support arrangements. The work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 1622 110 mm dia (Wall Thickness - 3.2 to 3.8 mm) 1623 75 mm dia (Wall Thickness - 3.2 to 3.8 mm) 1624 Providing & fixing UPVC Floor trap of self cleansing designwith stainless steel grating complete in all respects. 1625 Multi Floor Trap (5 Ht) with height raiser and branch saddle strip of 50/75 mm outlet 1626 Plain Floor Trap (4 Ht) with 50 / 75 outlet and with height raiser 1627 P-Trap type Floor Trap 110 x 75 mm 1628 Extra for providing & fixing 125 mm dia C.P. grating in place of C.I. grating over floor traps. 1629 Providing & fixing of SS Floor Cleanout, round or square with rubber seal and flat round cover with screws and other required fitting complete as required. 1630 Providing and fixing 100 mm sand cast Iron grating for gully trap. 1631 Providing & fixing soil, waste and vent pipes. 1632 a) 100mm dia centrifugally cast iron S & S pipe. 1633 b)75mm dia centrifugally cast iron S & S pipe. 1634 Providing & fixing M.S. holder bat clamps of approved design to sand cast iron/centrifugally cast (Spun) iron S & S pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).Including cost of cutting holes & making good the walls etc. 1635 a) for 100mm dia pipe. 1636 b) for 75mm dia pipe. 1637 Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 1638 a) 100mm 1639 Sand cast iron S&S as per IS - 3989 1640 b) 75mm 1641 Sand cast iron S&S as per IS- 3989 1642 Providing and fixing plaincast iron S & S sanitary bend. 1643 a) 100mm 1644 Sand cast iron S&S as per IS - 1729 1645 b) 75mm 1646 Sand cast iron S&S as per IS - 3989 1647 Providing and fixing centrifugaly cast iron single equal plain junction of required degree. 1648 a) 100x100x100mm 1649 b) 75x75x75mm 1650 Providing and fixingcast iron terminal guard. 1651 a) 100mm 1652 b) 75mm 1653 Providing & fixingcast iron coller. 1654 a)100 mm 1655 Sand cast iron S&S as per IS - 3989 1656 b)75mm dia. 1657 Sand cast iron S&S as per IS - 3989 1658 Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters. 1659 a) 100mm 1660 b) 75mm 1661 Providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 1662 a) 100mm inlet & 75mm outlet. 1663 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 1664 15 mm nominal outer dia Pipes 1665 20 mm nominal outer dia Pipes 1666 25 mm nominal outer dia Pipes 1667 32 mm nominal outer dia Pipes 1668 Providing and fixing brass stop cock of approved quality. 1669 15 mm nominal bore 1670 Providing and fixing gun metal gate valve with wheel of approved quality. 1671 a) 25mm dia nominal bore 1672 b) 32mm dia nominal bore 1673 Providing and fixing ball valve (brass) of approved quality complete.(High or low pressure with plastic floats). 1674 a) 25mm. Nominal bore 1675 Providing and fixing 30 cm long unplasticised PVC connection pipe with brass unions. 1676 a) 15mm nominal bore 1677 Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions. 1678 a) 15mm nominal bore 1679 Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation 3concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 1680 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 1681 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 1682 With common burnt clay F.P.S.(non modular) bricks ofclass designation 7.5 1683 Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 1684 a) 15mm nominal bore 1685 Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 1686 a) 15mm nominal bore 1687 Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931 1688 a) 15mm nominal bore 1689 Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. 1690 Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 1691 25mm nominal bore, weighing not less than 62 gms 1692 Cutting holes up to 30x30 cm in walls including making good the same: 1693 With common burnt clay F.P.S. (non modular) bricks 1694 Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 1695 Making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc. 1696 Raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (Raising depth of manhole to be paid separately) : 1697 Rectangular manhole 90x80 cm with rectangular cover600 x 450 mm of grade LD - 2.5 1698 Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre) (if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) 1699 Repair to Plaster and Plinth Protection 1700 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 1701 Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 1702 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 1703 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 1704 Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of Engineer-In-Charge. 1705 With cement mortar 1:4 (1cement: 4 coarse sand) 1706 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 1707 15mm cement plaster on rough side of single or half brick wall of mix 1708 1:6 (1 cement : 6 course sand) 1709 6mm cement plaster to ceiling of mix : 1710 1:3 ( 1 cement : 3 fine sand) 1711 Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. 1712 Two coats 1713 Distempering with 1st quality acrylic distemper (ready made) having VOC content less than 50 gm per ltr. of approved manufacturer and of required shade and colour complete. as per manufacturers specification. 1714 One or more coats on old work 1715 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 1716 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: 1717 New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 1718 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade 1719 Old work (Two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface 1720 Washed stone grit plaster on exterior walls height upto 10 metre above ground level, in two layers, under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand ), furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 2 Kg of cement per square metre, top layer 15 mm cement plaster 1:1/ 2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10 mm nominal size), in panels with groove all around as per approved pattern, including scrubbing and washing the top layer with brushes and water to expose the stone chippings ,complete as per specification and direction of Engineer-in-charge (payment for providing grooves shall be made separately). 1721 Forming groove of uniform size in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer, including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge : 1722 15 mm wide and 15 mm deep groove 1723 Repairs to Door / Windows 1724 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 1725 Of area 3 sq. metres and below 1726 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 1727 Of area 3 sq. metres and below 1728 Renewing glass panes, with putty and nails wherever necessaryincluding racking out the old putty: 1729 Float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 1730 Renewal of old putty of glass panes (length) 1731 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 1732 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 1733 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 1734 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coatwith approved steel primer all complete Fixed to steel windows by welding 1735 Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete 1736 300 mm weighing not less than 200gms. 1737 250 mm weighing not less than 150gms. 1738 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 1739 100X58X1.90 mm 1740 Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 1741 Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 1742 300 x 10mm 1743 150 x 10mm 1744 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm. 1745 125 mm 1746 Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. 1747 Twin rubber stopper 1748 Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. 1749 Providing and fixing to existing door frames. 1750 30 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam PUF)/ Polystyrene foam to be used as filler material throughout the hollow panel, castedmonolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS: 14856, complete as per direction of Engineer-in-charge. 1751 Providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws. 1752 30 mm thick shutterswith ISI marked M.S. butt hinges with necessary screws 1753 With ISI marked stainless steel butt hinges of required size 1754 Kiln seasoned and chemically treated hollock wood 1755 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm allcomplete. 1756 With 12 mm mild steel U beading 1757 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 1758 Fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 1759 Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 1760 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 1761 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 1762 Providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 1763 4.0 mm thick glass panes 1764 Applying priming coat : 1765 With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood 1766 With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 1767 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 1768 over an under coat of suitableshadewithordinarypaint of approved brand and manufacture 1769 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 1770 One or more coats on old work 1771 Repairs to Flooring 1772 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 1773 Nominal concrete 1:3:6 or richer mix (i/c equivalentdesign mix) 1774 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1775 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural ources) 1776 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 1777 25 mm thick 1778 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 1779 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete. 1780 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete.size of tile 600x 600 mm 1781 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete.size of tile 600x 600 mm 1782 Miscellaneous 1783 Providing and fixing 16 mm M.S. Fan clamps of standard shape and size in existing R.C.C. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 1784 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : 1785 Cement mortar 1:6 (1 cement : 6 coarse sand) 1786 Half brick masonry with common burnt clay F.P.S. (non modular) bricksof class designation 75 in superstructure above plinth level up to floor V level. 1787 Cement mortar 1:4 (1 cement :4 coarse sand 1788 Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry. 1789 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. 1790 Group B 1791 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 1792 Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. 1793 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 1794 2X1.5 sq. mm + 1 X 1.5 sq. mm earth wire 1795 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 1796 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 1797 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable and 1.5 sq.mm. FR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. 1798 Group B 1799 Rewiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. 1800 Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 1801 2 x 1.5 sq. mm 1802 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 1803 25 mm 1804 32 mm 1805 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 1806 100 mm X 100 mm X 60 mm deep 1807 150 mm X 75 mm X 60 mm deep 1808 Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 1809 Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings). 1810 Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 1811 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 1812 Supplying and fixing brass batten/ angle holder including connection etc. as required. 1813 Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 1814 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 1815 6 way, Double door 1816 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 1817 4 way (4 + 12), Double door 1818 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 1819 Single pole 1820 Single pole and neutral 1821 Triple pole 1822 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 1823 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 1824 Earthing with G.I. earth pipe 4.5 Mtr long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 1825 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 1826 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 1827 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 1828 Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. 1829 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 1830 Upto 450 mm sweep 1831 Supply of 15W SURFACE MOUNTED ROUND LED with all accessories as per standard item.. 1832 Supply of 20W SURFACE MOUNTED ROUND LED with all accessories as per standard item..(Such as Panasonic ADL04R206 or Equivalent). 1833 Supply of 15W WALL BRACKET LED BULB with all accessories as per standard item..(Such as Panasonic PBUM01157 or Equivalent). 1834 Supply of 20W SURFACE MOUNTED LED TUBE with all accessories as per standard item..(Such as Panasonic PBTM01207 or Equivalent). 1835 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 1836 Supplyof AC230/250 volts, 50 HZ exhaust fansincluding providingnuts, bolts, mounting FRLSame and other accessories etc.complete 1837 300 mm sweep 1300 rpm 1838 COST OF WATER SUPPLY PIPE LINE 1839 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, havingthermal stability for hot & cold water supply including all CPVC plain &brass threaded fittings This includes jointing of pipes & fittings with onestep CPVC solvent cement, trenching, refilling & testing of joints completeas per direction of Engineer in Charge. 1840 External work 1841 20 mm dia nominal bore 1842 25 mm dia nominal bore 1843 32 mm dia nominal bore 1844 40 mm dia nominal bore 1845 50 mm dia nominal bore 1846 65 mm dia nominal bore 1847 80 mm dia nominal bore 1848 Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc if required will be paid separately) : 1849 50 mm dia 1850 80 mm dia 1851 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 1852 20 mm nominal bore 1853 25 mm nominal bore 1854 32 mm nominal bore 1855 40 mm nominal bore 1856 50 mm nominal bore 1857 65 mm nominal bore 1858 80 mm nominal bore 1859 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) 1860 Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality 1861 LD- 2.5 1862 Rectangular shape 600*450 mm internal dimensions 1863 Constructing masonry gate valve Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 1864 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 1865 Constructing masonry Chamber 60x45x50 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for water meter complete with C.I. double flap surface box 400x200x200 mm (inside) with locking arrangement and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 1866 with common burnt clay F.P.S.(non module) brick of class designation 7.5 1867 SEWERAGE SYSTEM 1868 Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m : 1869 All kinds of soil 1870 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 1871 Pipes, cables exceeding 300 mm dia but not exceeding 600 mm dia 1872 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 1873 150 mm dia. R.C.C. pipe 1874 450 mm dia. R.C.C. pipe 1875 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size) 1876 150 mm diameter S.W.Pipe (L*.35*.10) 1877 450 mm diameter S.W.Pipe (L*.6*.15 ) 1878 Constructing brick masonry manholein cement mortar 1 : 4 (1 cement : 4 coarse sand) with RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4gradestone aggregate 20mm nominal size); foundation concrete 1:4:8 mix(1 cement : 4 coarse sand : 8 gradedstoneaggregate40 mm nominalsize) insideplastering 12 mm thickwith cementmortar 1:3 (1cement 3 coarse sand ) finished with a floating coat of neat cement and makingchannels incementconcrete 1:2:4 (1cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) finishd with a floating coat ofneatcement completeasper standard design 1879 Inside size 90 x 80 cm & 45 cmdeep including CI cover with frame (light duty) 455 x 610mm internal dimensions, total weight of cover & frame to be not lessthan 38 kg (weight of cover 23 kg and weight of frame 15 kg) 1880 With common burnt clay F.P.S.(non modular) bricks of classic designation 7.5 1881 Extra for depth for manholes: 1882 size 90 X 80 cm 1883 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 1884 Constructing Brick Masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top with FPS bricksclass designation 75in cement mortar 1:4 (1 cement : 4 Coarse sand), inside cement plaster 12mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of of neat cement, foundation concrete 1:3:6 mix ( 1 cement : 3 coarse sand :6 graded stone aggregate 40mm nominal size) and making necessary channel in Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design. 1885 0.91m deep with SFRC cover and frame (heavy duty HD-20 grade designation) 560mm internal diameter conforming to I.S:12592, total weight of cover and frame to be not less than 182Kg. fixed in cement concrete 1:2:4 mix (1cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size) including centering, shuttering all complete.(Excavation foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) 1886 with common burnt clay F.P.S.(non module) brick of class designation 7.5 1887 Extra depth for circuler type manholes 0.91 m internal dia ( at bottom ) beyond 0.91m to 1.67 m . 1888 with common burnt clay F.P.S.(non module) brick of class designation 7.5 1889 Providing and fixing square mouthS. W. Gully trapclass SP-1 complete with C.I. gratingbrickmasonry chamber with water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 1890 180 x 150 mm. size P type 1891 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 1892 Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : 1893 With 20x20 mm square bar 1894 Cleaning of chocked sewer line by diesel running vehicle mountinghydraulic operated high pressure suction cum jetting sewer cleaningmachine fitted with pump having 4000 litres suction capacity and6000 litres water jetting tank capacity including skilled operator,supervising engineer etc. for cleaning and partial desilting of manholesand dechocking of sewer lines. Dechocking and flushing of sewerline from one manhole to another by high pressure jetting system of2200 PSI for sewer line from 150mm dia upto 300mm 1895 Cleaning and desilting of gully trap chamber, including removal ofrubbish mixed with earth etc. and disposal of same, all as per thedirection of Engineer-in-charge. 1896 COST EXTERNAL ELECTRICAL 1897 SUBHEAD - I - MAIN BOARDS 1898 METER BOARDS 1899 Supply, installation, testing and commissioning of M.V. cubical type totally enclosed dust, dump and vermin proof Meter Bords complete with bus bars, MV danger notice plate, on surface ISI marked Electronic kWh meter, indication lamps, CTs, Interconnection with suitable capacity aluminium strips / rods, door covers, seperate compartment for each meter, glass inspection window, connection of incoming and outgoing cables with thimbles, powder coated having following incoming and outgoingMCBs MCCBs and kWh meters complete as required. 1900 PANEL- KITCHEN DINING 1901 INCOMER 1902 1 No.40 Amp FP MCCB, 15 kA breaking capacity with thermal release and adjustable setting and with rotary handle. 1903 METERING & INDICATION 1904 1 set of R,Y,B phase indicating lamps 1905 Digital Multifunction meter for Voltage, Current & KW with selector switch. Each with 3nos. of 2A SP MCB & 3nos 40/5A CTs (40A/500V) rating 1906 1 Sets of Breaker ON-OFF-TRIP, Spring charged indication Lamps as required. 1907 BUS-BAR 1908 1 Set of 50A TPN Aluminium Bus Bar with colour coded PVC Sleeves 1909 OUT GOING: 1910 2 Nos. 25A TPN MCB of 10kA 1911 3 No. 40A DP MCB of 10kA. 1912 Supplying,Receiving, fixing, testing & commissioning ofabove described Panel 1913 METER BOARDS - TYPE-III (2NOS) & TYPE II (2NOS) 1914 INCOMER 1915 1 No.63 Amp FP MCCB, 15 kA breaking capacity with thermal release and adjustable setting and with rotary handle. 1916 METERING & INDICATION 1917 1 set of R,Y,B phase indicating lamps 1918 Digital Multifunction meter for Voltage, Current & KW with selector switch. Each with 3nos. of 2A SP MCB & 3nos 63/5A CTs (63A/500V) rating 1919 1 Sets of Breaker ON-OFF-TRIP, Spring charged indication Lamps as required. 1920 BUS-BAR 1921 1 Set of 100A TPN Aluminium Bus Bar with colour coded PVC Sleeves 1922 OUT GOING: 1923 4 Nos. 40A TPN MCB of 10kA 1924 2 Nos. 40A DP MCB of 10kA. 1925 Supplying,Receiving, fixing, testing & commissioning ofabove described Panel 1926 METER BOARDS -DORMITORY BOYS & GIRLS 1927 INCOMER 1928 1 No.63 Amp FP MCCB, 15 kA breaking capacity with thermal release and adjustable setting and with rotary handle. 1929 METERING & INDICATION 1930 1 set of R,Y,B phase indicating lamps 1931 Digital Multifunction meter for Voltage, Current & KW with selector switch. Each with 3nos. of 2A SP MCB & 3nos 63/5A CTs (63A/500V) rating 1932 1 Sets of Breaker ON-OFF-TRIP, Spring charged indication Lamps as required. 1933 BUS-BAR 1934 1 Set of 100A TPN Aluminium Bus Bar with colour coded PVC Sleeves 1935 OUT GOING: 1936 4 Nos. 40A TPN MCB of 10kA 1937 2 Nos. 40A DP MCB of 10kA. 1938 Supplying,Receiving, fixing, testing & commissioning ofabove described Panel 1939 METER BOARDS - PRINCIPLE RESIDENCE 1940 1 No.40Amp FP MCCB, 15 kA breaking capacity with thermal release and adjustable setting and with rotary handle. 1941 PANEL -SCHOOL BUILDING & MP HALL 1942 PANEL -SCHOOL BUILDING & MP HALL 1943 INCOMER 1944 1 No.63 Amp FP MCCB, 15 kA breaking capacity with thermal release and adjustable setting and with rotary handle. 1945 METERING & INDICATION 1946 1 set of R,Y,B phase indicating lamps 1947 Digital Multifunction meter for Voltage, Current & KW with selector switch. Each with 3nos. of 2A SP MCB & 3nos 63/5A CTs (63A/500V) rating 1948 1 Sets of Breaker ON-OFF-TRIP, Spring charged indication Lamps as required. 1949 BUS-BAR 1950 1 Set of 100A TPN Aluminium Bus Bar with colour coded PVC Sleeves 1951 OUT GOING: 1952 4 Nos. 40A TPN MCB of 10kA 1953 3 No. 40A DP MCB of 10kA. 1954 Supplying,Receiving, fixing, testing & commissioning ofabove described Panel 1955 SUBHEAD - II - EARTHING 1956 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering watering pipe 2.7 metre long etc. with charcoal/ coke and salt as required. 1957 Earthing with Cu. earth Plate 600mm x 600mm x 3mm thick includingaccesssories, and providingmasonary enclosurewith cover plate (CI heavy duty) having locking arrangement and watering pipe pipe of 2.7 mtr long etc. with charcoal or coke and salt) as required. 1958 Supplying and laying 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode, including connection with G.I. nut, bolt, spring, washer excavation and refilling etc. as required. 1959 Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required. 1960 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 1961 SUBHEAD - III - SUPPLYING & LAYING OF CABLE 1962 Laying of one number PVC insulated & PVC sheathed/ XLPE Power cable of 1.1 KV grade of following size in the existing RCC/HUME/METAL pipe as required. 1963 Upto 35 sq.mm 1964 Above 35 sq. mm and upto 95 sq. mm 1965 Above 95 sq.mm and upto 185 sq.mm 1966 Above 185 sq.mm and upto 400 sq.mm 1967 Supply of following sizes of XLPE insulatedAluminum conductor strip/ wire Armoured, overall PVC sheathed 1.1 KV grade cables conforming to relevant IS-7098 Code and technical specifications. 1968 4 X 10 sq. mm 1969 4 X 16 sq. mm 1970 3½ X 25 sq. mm 1971 3½ X 95 sq. mm 1972 3½ X 150 sq. mm 1973 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 1974 4 X 10 sq. mm (25mm) 1975 4 X 16 sq. mm (28mm) 1976 3½ X 25 sq. mm (28mm) 1977 3½ X 95 sq. mm (45mm) 1978 3½ X 150 sq. mm (50mm) 1979 Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. 1980 150 mm dia 1981 300 mm dia 1982 SUB HEAD -IV :EXTERNAL LIGHTING 1983 Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. 1984 Above 6.5 metre and upto 8.0 metre 1985 Supplying, installation, testing and commissioning of Gate light fitting suitable for 42 watt IP 65LED having system lumen output of minimum 4200 lumenscomplete with all accessories and lamp. Wipro Cat No.: 1986 Supplying, installation, testing and commissioning of 45W LED Street LightIP66 LED with High performance having system lumen output of minimum 9900 lumens, contemporary designed housing made of die-cast aluminium, with street optic LENS for uniform light distribution. PF better than 0.9, CRI better than 70 complete with all accessories. Wipro Cat No.: LR 02-102-XXX-57-G2 Street light 1987 Supplying, installation, testing and commissioning of 45W LEDSolar Street Light On 6 Meter GI octagonal Pole having Compact, Aesthetic, Eco friendly & modern integrated Solar street light in extruted Aluminum construction with high efficiency monocrystalline silicon photo voltaic panel, high efficacy SMD LED 6500K having secondary lens optics for street lighting distribution, high performance lithium ferro phasphate ( life P04)attery, MPPT charge controller & Intelligent control module/sensor with higher reliability, long service life, suitable for easy & quick installation. Wipro Cat No.:LR 14-591-XXX-65-XX. 1988 Supply, testing & commissioning of 6.0 meter high G.Ioctagonal pole (Above Ground Level) with single/double arm as per requirement of suitable length with inbuilt junction box with 6A SP MCB, connectors for incoming/outgoing cable connection and 300mm x 300mm x 20 mm thick base plate and bracket (double arm/single arm whichever required) complete in all respect. 1989 Providing, installation of 200 x 150 x 125 mm polycarbonate weather proof (IP-55) junction box and SP MCB’s and terminal block. Supplying and laying cable through GI pipe upto junction box including excavation and back filling, wiring with 2 x 2.5 sq.mm PVC insulated 1100 volts grade copper conductor wires from junction box to lighting fixturecomplete. 1990 Supplying and laying cable through GI pipe upto junction box including excavation and back filling, wiring with 2 x 2.5 sq.mm PVC insulated 1100 volts grade copper conductor wires from junction box to lighting fixturecomplete. 1991 COST MAIN ENTRY GATE WITH GUARD ROOM 1992 Earth Work 1993 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil 1994 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.All kinds of soil 1995 Concrete Work 1996 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:5:10 (1 cement : 5 coarse sand (zoneIII) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) 1997 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size) 1998 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 1999 Reinforced Cement Concrete 2000 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 2001 Upto plinth level 2002 (i) R.C.C. work in Footing 2003 (ii) R.C.C. work in Beam 2004 (iii) R.C.C. work in Columns 2005 Above plinth to floor-V lvl 2006 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 2007 (i) R.C.C. work in Beam 2008 (ii) R.C.C. work in Columns 2009 (iii) R.C.C. work in Slab 2010 Centering and shuttering including strutting, propping etc. and removal of form for all heights : 2011 Foundations, footings, bases of columns, etc. for mass concrete. 2012 Columns,Pillars, Piers, Abutments, Posts and Struts. 2013 Suspended floors, roofs, landings, balconies and access platform. with water proof ply 12 mm thick 2014 Lintels, beams, plinth beams, girders, bressumers and cantilevers. with water proof ply 12 mm thick 2015 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 2016 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500 D or more. 2017 Masonry Work 2018 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) 2019 Wood and PVC Work 2020 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. 2021 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. 2022 Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. Twin rubber stopper 2023 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete(a) 125 mm. 2024 Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 2025 Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. 2026 300 x 10mm 2027 200 x 10mm 2028 Steel Work 2029 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 2030 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 2031 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 2032 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes. 2033 Flooring 2034 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 2035 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete 2036 Finishing 2037 12 mm cement plaster on the fair side of single or half brick wall (a) 1:6 (1 cement: 6 coarse sand) 2038 15 mm cement plaster on rough side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand). 2039 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 coarse sand) 2040 6 mm cement plaster on celling (a) 1:3(1 cement:3 fine sand) 2041 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer. 2042 Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm) 2043 Applying priming coat: 2044 With ready mixed aluminium primer of approved brand andmanufacture on resinous wood and plywood 2045 With ready mixed red oxide zink chromate primer of approved brand and manufacture on steel galvanised iron/steel works. 2046 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture 2047 Finsihing with Epoxy paint (two or more coats) at all locations pepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work. 2048 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2049 Water Proofing 2050 Painting top of roofs with bitumen of approved quality @ 17kg per 10 sqm impregnated with a coat of coarse sand at 60 cudm per 10 sqm, including cleaning the slab surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil complete : 2051 Supply & Fixing of Prepainted coloured Trapezoidal or approved profiled Sheeting 1000-1020 mm cover width, 28-30 mm high crests with subtle square fluting in the five pan at nominal 190-255 mm (as approved by EIC) centre-to-centre manufactured out of 0.50 mm TCT hi-tensile prepainted Zincalume /Galvalume steel (AZ-150 gsm. Aluminium –Zinc alloy metallic coating of total both sides 550 MPa yield stress as per AS-1397). Colour/ Exterior coat of RMP 20 micron top coat applied over 5 micron primer and a 5 micron polyester back coat applied over 5 microns primer OR equivalent coating/painting. The sheet shall have wide pans with stiffening ribs for effective water shedding and special male/female ends with full return legs on side laps for purlin support. The male end of the sheet shall have anti-capillary flute at side laps to prevent leakages. The sheet shall be fixed by means of anti corrosive approved make Rust Shield (Epoxy Polymer) coated self-drilling self tapping fasteners 12-14 X 55 mm with EPDM seals through crest for roofing and 12-24 X 20 mm through valley (pans) for wall cladding. The sheet shall be supplied in lengths maximum up to 6-12 meter long to suit site dimensions. The scope includes all sealing of joint, curves, edges or other accessories with silicon sealant. 2052 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 2053 ELECTRICAL 2054 SUB HEAD - I: CIRCUIT CUM POINT WIRING 2055 SWITCH CONTROL LIGHT POINTS 2056 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 2057 Group C 2058 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without Independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as required. (Switch Control Secondary Points) 2059 Group C 2060 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Switch Control Primary Points) 2061 Group C 2062 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (withoutIndependent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as required. (Switch Control Secondary Points) 2063 Group C 2064 MCB CONTROL LIGHT POINTS 2065 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Switch Control Primary Points) 2066 Primary point controlled by one MCB. 2067 Same as item above but Secondary point. i.e. Points to be looped with Primary pointwith 2.5 sqmm wire and Point wiring 2068 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 2069 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2070 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 2071 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 2072 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 2073 2 x 10 sq. mm + 1 x 10 sq.mm earth wire 2074 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 2075 4 X 16 sq. mm + 2 X 6 sq. mm earth wire 2076 Supplying and fixingsuitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing3 pin 5/6 Amp modular socket outlet and 5/6 A modular switch, connection etc. as required. 2077 Supply and Wiringfor 250 volts singlephase and neutral 2 Nos 6 amps socket outlate with control by 1 No switched with 2.5 sq.mm PVCinsulatedcopper conductor1100 volts grade stranded flexible FRLS wires inconcealed or surface mounted 25 mm dia 2mm thickPVC conduit including providing and fixing of 6 amps 3 pin switch socket outlet of aprpoved make and design in 2 mm thick GI box with grid plate and earthingofthird pin of the socket with2.5Sq. mm PVC insulated copper conductor strandedflexibleFRLSwire.(maximum four no. of switches socket shall be connected on onecircuit) 2078 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 2079 Supplying and fixing 63 A, 415 V, TPN Industrial type socketoutlet, with 4 pole and earth, metal enclosed plug topalongwith 63 A C curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. 2080 Supplying and fixing 80 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 80 A C curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. 2081 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. 2082 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess i/c providing and fixing 25 amp modular socket outlet and 25 Amps modular SP MCB, “C” curve including connection, painting etc. as required. (ACs & Gysers) 2083 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 2084 Telephone socket outlet 2085 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 2086 1 or 2 Module (75mmX75mm) 2087 6 module (78mm X 205 mm X 50 mm) 2088 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 2089 3 pin , 5/6 amps socket outlet 2090 5/6 amps switch 2091 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 2092 25 mm 2093 32 mm 2094 SUBHEAD -II - FITTINGS & FIXTURES 2095 Supply, Installation, Testing and Commissioning of 10 W Bulk head Light. 2096 Supply, Installation, Testing and Commissioning of 5W Mirror Light. 2097 Supply, Installation, Testing and Commissioning of 18W Surface/Recessed Mounted LED circular Downlighter. 2098 Supply, Installation, Testing and Commissioning of 18/20W Wall/Surface mouted 4 ft. LED 2099 Supply, Installation, Testing and Commissioning of 15WSurface mountedLED Square Downlighter. 2100 Supply, Installation, Testing and Commissioning of 12/9WRecessed mountedLED circular Downlighter. 2101 Supply, Installation, Testing and Commissioning of9W (Nominal)Wall Bracket Light 2102 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019),THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 2103 SupplyInstallation, Testing and Commissioning of 250 mm dia Domestic Exhaust Fan 2104 SUBHEAD - III - DISTRIBUTION BOARDS 2105 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 2106 6 way, Double door 2107 8 way, Double door 2108 12 way, Double door 2109 Supplying and fixing following way, three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator) 2110 4 way (4 + 12), Double door 2111 6 way (4 + 18), Double door 2112 8 way (4 + 24), Double door 2113 Supplyingand fixingoffollowingwayssurface/recessmounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required . (Note :Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 2114 12 way (4 + 36), Double door 2115 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2116 Single Pole 2117 Single Pole Neutral 2118 Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2119 40 A 2120 63 A 2121 Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2122 25 A 2123 40 A 2124 63 A 2125 Supplying and fixing following rating, double pole, (single phaseand neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2126 25 A 2127 40 A 2128 63 A 2129 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.