| 1 | Earth work excavation for foundation (for narrow excavation) in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by thedepartmental officers with an initial lead of 10 mts and initial lift of 2 mts. and clearing and levelling the site, etc., complete complying with standard specification. |
| 2 | Footings (0-2m depth) |
| 3 | Footings (2-3m depth) |
| 4 | Plinth Beam |
| 5 | Refilling with excavated earth other than sand with an initial head load of 100 mts. and depositing the earth as shown by the departmental officersin layers of not more than 15 cm thick well rammed, watered and consolidated etc. complete complying with standard specification |
| 6 | Supplying and providing Anti termite pre construction treatment using aldrin or dealdrin or heptochlor as per relavent IS 6313 (part II) code including cost of all materials, labour, hore charges for T&P etc complete. |
| 7 | Supplying and filling GRAVELin \"foundation andbasement with filling sand in layers of not more than 15cm.thick well rammed watered and compacted -1m3 etc., complete complying with standard specification. |
| 8 | Supplying and filling in foundation, basement, etc with filling M.Sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. |
| 9 | Plain Cement Concrete 1:4:8 (one cement, four sand and eight hard broken stone jelly) using 40mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers. |
| 10 | Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oakjoists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid) |
| 11 | Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid) |
| 12 | For plane surfaces such as vertical slab, side slabs of boxing, vertical drops, facia, vertical wall, etc. |
| 13 | For plane surfaces such asrectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc. |
| 14 | Plain Cement Concrete 1:1.5:3 (one cement, one and half Parts of crushed stone M-sand and three coarse aggregates) using 20mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges etc., complete as per standard specification (The crushed stone sand to be used on cocrete work shell conform to gradation as per IS :383-1970 and aiso as per IS 456-2007) |
| 15 | Providing and laying in position, standardised concrete Mix M-20 Grade in accordance with IS 456 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m) 7670 kg. of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials). |
| 16 | Below Ground Level |
| 17 | Ground Floor |
| 18 | Supplying, fabricating and placing in positionRibbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification.(Contractor has to make his own arrangements for the supply of steel and binding wire) |
| 19 | Brick work in Cement Mortor 1:5 using ii class ground moulded chamber bricks of size 9\"x43/8\"x23/4\" for foundation and basement including curing etc.,complete complying with standard specification |
| 20 | Below Ground Level |
| 21 | Ground Floor |
| 22 | First Floor |
| 23 | Paving the floor with Vitrified Marbonite tiles of approved quality and colour of size 600x600x8mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3(one cement three sand) 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officer.The colour & quality of tiles should be got approved by Municipal Engineer before use on work |
| 24 | Paving the floor with kota stone slab of size 600 x 600 of 18 / 20mm (un-polished) in all floors laid in of cement mortor 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 20mm thick and pointed with colour cement neatly including polishing with polishing stone and oxalic acid etc., so as to perfectly smooth and glossy and including hire charges for polishing machine and power consumption charges etc. The kota stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification. |
| 25 | Finishing the top with Machine Pressed Ornamental Tiles of approved quality laid in cement mortar 1:3 20mm thick mixed with WPC at 2% by weight of cement used and top pointed with the same red oxide mixed mortar etc complete, complying with standard specifications |
| 26 | Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers. |
| 27 | Special Ceiling Plastering with cement mortar 1:3,10 mm ,thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications (S.I.306) |
| 28 | Plastering with Cement Mortar 1:5 (One cement and Five Crushed stone sand ), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers. |
| 29 | Painting two coats with ready mixed Plastic Emulsion Paint approved quality and colour over a priming coat, including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification. - 10 sq.m |
| 30 | Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete |
| 31 | Providing and laying, spreading and compacting graded stone aggregate to Wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant carriage to mixed material by tipper to site laying in uniform layers with paver in sub base / base course on well prepared surface and compacting with vibratory roller to achive the desired density complete as per clasue 406 of MORTH specifications. |
| 32 | Supplying and laying Rubberised interlocking Paver blockM40 grade Providing and laying of63mmthick high strength type conforming IS 15658-2006 of rubberized interlocking paver lock to required size as directed by the departmentalofficers of minimum compressive strength of 40N/mm2 in uniform shape of approved make to be laid in flurring bone pattern with stone dust cushion below the uniform shap of approvednon skitting surface in the top and the rate including levelling the base preparation ofpavers as sub base, stone dust cushion 150mm thick layingout of pavement cut the pieces to fix the edge vibring the pavers,sweeping tranporting loading unloading of laying paver block as per standard specification,. |
| 33 | Providing and fixing Bitumen Pad for Expansion joint in between pavement slabs to 12mm thick and fixed as shown in the drawing including cost and conveyence of expansion joints including shalimar pad and joint sealent etc, complete as per standard specification. SOR 23-24. P.No 63 |
| 34 | Supplying and fixing in position best approved of BIS quality PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the R0.45 roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of \"U\" clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification. |
| 35 | ROLLING SHUTTERS (WITH ISI MONOGRAM) Supplying and erecting pull and push type rolling shutter with I.S.I make of approved size and section using 18 G.I sheet. The shutter shall be painted with one coat of red oxide primer and the rate is inclusive of Hood covers, transportation charges etc(GEAR operated type from 8sq.m. to 12 sq.m area) |
| 36 | ELECTRICAL ITEMS |
| 37 | ElectricalDatafor the year |
| 38 | Supply and fixing 16amps DP switch with metal clad(Front handle) of 500 V with F & N on suitable teak wood Board of size 30cmx20cmx6 cm including necessaryinternal conection,earth connection etc.,complete (M-1363). P.No : 173 |
| 39 | Earthing as per ISI Specification with an earth electrode of 2.1mt class \"B\" GI pipe of dia not less than 40mm and with 20mm dia copper earth flat of size 125mm x50mmx6mm, with funneling arrangement using charcoat, common salt, G.I.reducer, checj nuts etc.,and mansonry workand providing RCC cover slab 38mm thick for the Brick mansory including cost of steel and fabrication of reinforcement etc., complete in all respectes as directed by the departmental officers. (SD 211) |
| 40 | Supply and run of 2 of No.8 SWG GI wire for guarding with cradle with No.8 SWG GI wire at the equal interval of 1.5 metre (SD 75) |
| 41 | Supply and fixing of 8 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB switch as incoming and 6 nos. 6A to 32A SP MCB as outgoing on wall with earth connection only. Lower End (SD 506) |
| 42 | Supplying and fixing of 5 A 3 pin and 2 pin combined flush type wall socket with 5A flush type switch concealed in suitable MS box in flush with wall and covered with 3mm thick hylem sheet (SD 137) |
| 43 | Supplying and fixing of 5 A /15A 3 pinflush type wall socket with15A flush type switch concealed in suitable MS box in flush with wall and covered with 3mm thick hylem sheet including cost of wall socket, switch and labour charges fo wall cutting, grouting, flushing and making good, painting with primary and finishing coat for MS box etc., complete as directed by the departmental officers. (SD 141) |
| 44 | Wiring with 2x1.5sqmm PVC insulated single core unsheathed copper conductor cable of 1100V grade with ISI mark confirming to IS: 694/1990 in suitable PVC rigid pipe of 1.8mm thick with ISI mark concealed in wall and ceiling with PVC accessories in flush with wall including the cost of cable, pvc pipe and specials, ceiling rose, flush type 5ams SP mark switch,PVC junction box, 16gauge MS switch box 100mm x 100mm x 75mm covered by laminated hylem sheet 3mm thick, cement, labour and making good of concealed portion with suitable colour for concealed PVC LIGHT point. (SD 26) |
| 45 | Wiring with 2x1.5sqmm PVC insulated single core unsheathed copper conductor cable of 1100V grade with ISI mark confirming to IS: 694/1990 in suitable PVC rigid pipe of 1.8mm thick with ISI mark concealed in wall and ceiling with PVC accessories in flush with wall including the cost of cable, pvc pipe and specials, ceiling rose, flush type 5ams SP mark switch,PVC junction box, 16gauge MS switch box 300mm x 200mm x 75mm covered by laminated hylem sheet 3mm thick, cement, labour and making good of concealed portion with suitable colour for concealed PVC LIGHT point. (SD 27) |
| 46 | Wiring with 2x1.5sqmmPVC insulated SC unsheated CU conductor of 1100 V grade with ISI mark confirming to IS: 694/1990 in suitable PVC rigid pipe of 1.8mm thick with ISI mark concealed in wall and ceiling with PVC accessories in flush with wall for 5 AMPS 3 PIN C.S. PLUG POINT AT CONVENIENT PLACES including the cost of cable, PVC pipes and specials, brass screws, flush type 5 amps 3 Pin C.S. plug, 16 gauge Msjoint box, 16 gauge MS switch box covered by laminated hylem sheet 3mm thick, cement, labour and making good of the concealed portion with suitable colour for open plug point. (SD 11) |
| 47 | Supply and run off 2 of 1.50sqmm PVC insulated single core unsheathed copper conductor cable of 1100 V grade with ISI markconfirming to IS:694/1990 with continiousearth connection by means of 1.50 sqmm PVC insulated single core unsheathed copper conductor cable confirming to IS:694/1990 in suitable PVC rigid pipe 1.8mm thick concealed in wallfor mains including the cost of PVC pipes and specials, cables, cement, brass screws, T.W plugs, saddles and labour etc., complete in all respects as directed by the departemental officers. (SD 67) |
| 48 | Supply and run off 2 of 4 sqmm PVC insulated single core unsheathed copper conductor cable of 1100 V grade with ISI markconfirming to IS:694/1990 with continiousearth connection by means of 1.50 sqmm PVC insulated single core unsheathed copper conductor cable confirming to IS:694/1990 in suitable PVC rigid pipe 1.8mm thick concealed in wallfor mains including the cost of PVC pipes and specials, cables, cement, brass screws, T.W plugs, saddles and labour etc., complete in all respects as directed by the departemental officers. (SD 68) |
| 49 | Supply and fixing of single box type 4\"36W fluorescent fitting complete with electronic ballast with TW round blocks on wall or ceiling with flu tube with PVC unsheathed FRLS Copper leads from terminals to the fitting. (SD-87) |
| 50 | GST Amount for providing Service to Government Contract Works for the Above construction works. (GST Amount is the Total GST Amount for total overall quoted amount above this row for this work) |