Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 03-06-2025 | REVISED CSD | Technical Bid | 06-06-2025 |
| 2 | 02-06-2025 | DATE EXTEND | Date | 06-06-2025 |
| Sl. No. | Item Description |
| 1 | CONSTRUCTION OF COURT BUILDING AT. KARANJA TQ. KARANJA DIST. WASHIM (WITH ELECTRIFICATION) |
| 2 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means. Bd.A.1 Page 1 Number 259. SSR I.No. 21.02, Sr.No.721, P.No.153 (For Parking Floor) 1. For Court Building- 3140.77 cum2. Pump house & Sump well 51000 Lt- 61.55 Cum3. Compound Wall - 162.07 cum4. CC Drain - 1041.65 cum5. Parking Shed For 2 Wheelers- 86.4 cum 6. Parking Shed For 4 Wheelers- 69.20 cum7. Retaining Wall 3m - 787.50 cum8. RCC GATE 5.5m Wide - 35.28 cum 9. Cattle\"s Trap - 37.70 cum10. C.D.Work - 200.32 cum11. security room - 101.52 cum |
| 3 | Excavation for foundation in earth, soils of all types, sand,gravel and soft murum, including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5m to 3.0m) By Mechanical Means Spec.No.: Bd.A.2 Page Number 259 SSR I.No.21.04, Sr.No.723 P.No.153 (For Parking Floor) 1. For Court Building - 104.70 cum2. Compound Wall - 5.22 cum3. Pumphouse & sump well 4.93 cum4. parking shed 4 wheeler - 2.3 cum 5. Retaining Wall 3m - 26.25 cum 6. RCC GATE 5.5m Wide 1.16 cum7. C.D.Work 6.68 cum 8. security room - 3.20 cum |
| 4 | Excavation for foundation in Hard murum including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from1.5 to3.0m.) By Mechanical Means Spec No. : Bd.A.2 Page Number 259 .SSR I.No.21.08, Sr.No.727, P.No.154 1. For Court Building- 667.41 cum 2. Compound Wall :- 31.27 cum3. Pump house & Sump well 51000 Lt. :- 58.68 cum4. Parking Shed For 2 Wheelers :- 17.28 cum 5. Parking Shed For 4 Wheelers :- 13.82 cum6. Retaining Wall 3m - 157.5 cum7. RCC GATE 55 m wide - 7.04 cum 8. C.D. Work - 156.20 cum9. security room - 19.16 cum |
| 5 | Filling in plinth and floors with approved excavated material in 15cm. to 20cm. Layers including watering and compacting etc. complete. Spec. No. Bd.A.11 Page 1 Number 263. SSR I.No. 21.36, Sr.No. 750, P.No. 157 1. For Court Building - 667.41 cum2. Security room - 19.16 cum |
| 6 | Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compactionetc. complete.. Spec. No. Bd.A.11 Page 1 Number 263. SSR I.No. 21.37, Sr.No. 751, P.No. 157 (Court Building - 13945.25 cum Security room - 94.12 cum |
| 7 | Conveying materials obtained from road cutting including all lifts, laying in layers of 20cm to 30cm. breaking clods, dressing to the required lines, curves, grades and section, watering and compacting to not less than 97% of standard Proctor density for a lead of over 50m. to 300m. inclusive from the site of excavation to the site of deposition as directed. Spec. No. MORTH 305SSR I.No. 2.25, Sr.No. 98 P.No.241. Court Building-(For Parking Floor) - 3245.47 cum 2. Pump house & Sump well 51000 Lt. - 26.73 cum3. Internal RCC road - 238.08 cum |
| 8 | For -Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering10yearsguaranteeon bond paper...Spec. No. As directed by Engineer in Charge. SSR I.No.21.22, Sr.No.737, P.No.155 1. Court Building 5791.36 sqm2. security room - 300.64 sqm |
| 9 | Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) treatment by treating the backfill in immediate contact with foundation at the rate of 5 litres of emulsion concentrate of 1.0 percent of clorophyrifos per One Square Metre of verticalsurface area covering 10 years guarantee on bond paper.. Spec. No. As directed by Engineer in harge. SSR I.No.21.23, Sr.No.738 P.No.155 1. Court Building(For Parking Floor) - 3564.18 sqm2. security room - 123.96 sqm |
| 10 | Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent of clorophyrifos per One Square Metre of surface area covering ten years guarantee on bond paper... Spec. No. As directed by Engineer in harge. SSR I.No.21.24, Sr.No.739 P.No.156 1.Court Building- (For Parking Floor) 2154.25 sqm2. security room - 36 sqm |
| 11 | For Court Building-Providing preconstructional antitermite treatment as per I.S. 6313 (Part-I) to the soil along the external face of building by punching holes of 1.2 of 1.5 C.M. diametre about 30 -60 cm deep at 15 cm c/c as close to the wall as possible and to inject 0.5 percent of aldrin or clorophyrifos at the rate of 7.5 litres per hole and sealing the same with proper filling and covering 10 years guarantee on bond paper... Spec. No. As directed by Engineer in harge. SSR I.No.21.25, Sr.No.740 P.No.156 (For Parking Floor) |
| 12 | Providing soling using 80 mm size trap metal in 15 cm. layer including filling voidswith Crushed sand/grit, ramming, watering etc. complete.. Spec. No. As directed by Engineer in charge. SSR I.No. 21.40, Sr.No. 754, P.No. 1571. For Court Building- 407.21 cum2. Pump house & Sump well 51000 Lt. :-12.31 cum 3. CC Drain :-310.50 cum 4. C.D.Work 13.72 cum 5. Security room 5.40 cum |
| 13 | For Court Building-Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ granite/quartzite/gneissmetalforbedblocks,foundationblocksand suchotheritems including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Sepc. No. Bd.E.4 Page Number 289 and B7, Page Number38. SSR I.No. 24.08, Sr.No. 830, P.176(For Parking Floor) |
| 14 | Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ granite/quartzite/gneissmetalforbedblocks,foundationblocksand suchotheritems including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Sepc. No. Bd.E.4 Page Number 289 and B7, Page Number38. SSR I.No. 24.08, Sr.No. 830, P.176 1. Court Building- (For Parking Floor) 263.30 cum2. Compound wall 10.60 cum3. Retaining Wall - 67.50 cum 4. RCC gate 3.52 Cum 5. Cattle trap 5.15 cum |
| 15 | For Court Building-Providing and laying Cast in situ/Ready Mix cement concrete M-15 of trap/ granite/quartzite/gneiss metal for coping to plinth or parapet, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) With fine aggregate (Crushed sand VSI Grade) Spec No. : Bd.E. 3/ Page No.288/ I.S. 456 (2000).SSR I.No.24.16, Sr.No.835, P.No.177 (For Fourth Floor) |
| 16 | For Court Building-Providing and laying in situ cement concrete M30 with tremix treatment for 200 mm thickness for flooring with groove cutting of 4mm wide and 20mm deep with necessary refilling with bitumen etc. complete. Spec. No. As directed by Engineer in charge.SSR I.No.33.31, Sr.No.1018, P.No.216 (For Parking Floor) |
| 17 | Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite/quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering, formwork ,cover blocks, laying/pumping, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Spec. No.Bd.F.3 Page 1 No. 298 and B.7, Page No.38. SSR I.No.25.13, Sr.No.837 P.No.1781. For Court Building- (For Parking Floor) - 1092.25 cum2. Cattle trap - 5.62 cum |
| 18 | For Court Building-Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Spec. No. : Bd.F.5 Page No. 300 and B.7, Page.No. 38.SSR I.No.25.33, Sr.No.842, P.No.180(For Parking Floor) |
| 19 | For Court Building-Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction For Court Building-finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Spec. No. : Bd.F.5 Page No. 300 and B.7, Page.No. 38.SSR I.No.25.33, Sr.No.842, P.No.180(ForFirst Floor) |
| 20 | For Court Building-Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Spec. No. : Bd.F.5 Page No. 300 and B.7, Page.No. 38.SSR I.No.25.33, Sr.No.842, P.No.180(ForSecondFloor) |
| 21 | For Court Building-Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Spec. No. : Bd.F.5 Page No. 300 and B.7, Page.No. 38.SSR I.No.25.33, Sr.No.842, P.No.180(ForThirdFloor) |
| 22 | For Court Building-Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Spec. No. : Bd.F.5 Page No. 300 and B.7, Page.No. 38.SSR I.No.25.33, Sr.No.842, P.No.180(ForFourth Floor) |
| 23 | For Court Building-Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Spec. No. :Bd.F.6 Page Number 300 and B.7, Page 1 Number38 Page.No. 38.SSR I.No.25.52, Sr.No.847, P.No.181 (For Parking Floor) |
| 24 | For Court Building-Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Spec. No. :Bd.F.6 Page Number 300 and B.7, Page 1 Number38 Page.No. 38.SSR I.No.25.52, Sr.No.847, P.No.181 (For For FirstFloor) |
| 25 | For Court Building-Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Spec. No. :Bd.F.6 Page Number 300 and B.7, Page 1 Number38 Page.No. 38.SSR I.No.25.52, Sr.No.847, P.No.181 (For Second FloorF) |
| 26 | For Court Building-Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Spec. No. :Bd.F.6 Page Number 300 and B.7, Page 1 Number38 Page.No. 38.SSR I.No.25.52, Sr.No.847, P.No.181 (For Third Floor) |
| 27 | For Court Building-Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Spec. No. :Bd.F.6 Page Number 300 and B.7, Page 1 Number38 Page.No. 38.SSR I.No.25.52, Sr.No.847, P.No.181 (For FourthFloor) |
| 28 | For Court Building -Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap / granite/quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversibleDrum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Spec. No. :Bd.F.8 Page Number 302 and B.7, Page 1 Number38 Page.No. 38.SSR I.No.25.58, Sr.No.850, P.No.182(For First Floor) |
| 29 | For Court Building -Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap / granite/quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Spec. No. :Bd.F.8 Page Number 302 and B.7, Page 1 Number38 Page.No. 38.SSR I.No.25.58, Sr.No.850, P.No.182(ForSecond Floor) |
| 30 | For Court Building -Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap / granite/quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Spec. No. :Bd.F.8 Page Number 302 and B.7, Page 1 Number38 Page.No. 38.SSR I.No.25.58, Sr.No.850, P.No.183(ForThirdFloor) |
| 31 | For Court Building -Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap / granite/quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Spec. No. :Bd.F.8 Page Number 302 and B.7, Page 1 Number38 Page.No. 38.SSR I.No.25.58, Sr.No.850, P.No.184(For Fourth Floor)( |
| 32 | For Court Building-Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Spec No.Bd.F.8 Page No. 302 and B.7, Page1No.38. SSR I.No.25.72, Sr.No.852 P.No.182(For Parking Floor) |
| 33 | For Court Building-Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Spec No.Bd.F.8 Page No. 302 and B.7, Page1No.38. SSR I.No.25.72, Sr.No.852 P.No.183 (For First Floor) |
| 34 | For Court Building-Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Spec No.Bd.F.8 Page No. 302 and B.7, Page1No.38. SSR I.No.25.72, Sr.No.852 P.No.184 (For Second Floor) |
| 35 | For Court Building-Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Spec No.Bd.F.8 Page No. 302 and B.7, Page1No.38. SSR I.No.25.72, Sr.No.852 P.No.185 (For Third Floor) |
| 36 | For Court Building-Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Spec No.Bd.F.8 Page No. 302 and B.7, Page1No.38. SSR I.No.25.72, Sr.No.852 P.No.186 (For Fourth Floor) |
| 37 | For Court Building-Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to\ give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)Spec No.Bd.F.8 Page No. 302 and B.7, Page1No.38. SSR I.No.25.78, Sr.No.855 P.No.183(For First Floor) |
| 38 | For Court Building-Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to\ give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)Spec No.Bd.F.8 Page No. 302 and B.7, Page1No.38. SSR I.No.25.78, Sr.No.855 P.No.184 (For Second Floor) |
| 39 | For Court Building-Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to\ give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)Spec No.Bd.F.8 Page No. 302 and B.7, Page1No.38. SSR I.No.25.78, Sr.No.855 P.No.185 (For Third Floor) |
| 40 | For Court Building-Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to\ give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)Spec No.Bd.F.8 Page No. 302 and B.7, Page1No.38. SSR I.No.25.78, Sr.No.855 P.No.186 (For Fourth Floor) |
| 41 | For Court Building-Providing and fixing in position to the exact profile and prestressing the high tensile strands to specified ultimate strength, standard end anchorages, cable ducts, grouting ducts after prestressing and bearing plates with wedges as per detailed drawings including necessary plant and machinery for prestressing etc. complete. Spec No.Bd.F.8 Page No. 302 and B.7, Page1No.38. SSR I.No.14.06, Sr.No.462 P.No.93(For First Floor) |
| 42 | For Court Building-Providing and fixing in position to the exact profile and prestressing the high tensile strands to specified ultimate strength, standard end anchorages, cable ducts, grouting ducts after prestressing and bearing plates with wedges as per detailed drawings including necessary plant and machinery for prestressing etc. complete (For Second Floor). Spec No.Bd.F.8 Page No. 302 and B.7, Page1No.38. SSR I.No.14.06, Sr.No.462 P.No.94 (For Second Floor) |
| 43 | For Court Building-Providing and fixing in position to the exact profile and prestressing the high tensile strands to specified ultimate strength, standard end anchorages, cable ducts, grouting ducts after prestressing and bearing plates with wedges as per detailed drawings including necessary plant and machinery for prestressing etc. complete. Spec No.Bd.F.8 Page No. 302 and B.7, Page1No.38. SSR I.No.14.06, Sr.No.462 P.No.95 (For Third Floor) |
| 44 | For Court Building-Providing and fixing in position to the exact profile and prestressing the high tensile strands to specified ultimate strength, standard end anchorages, cable ducts, grouting ducts after prestressing and bearing plates with wedges as per detailed drawings including necessary plant and machinery for prestressing etc. complet e. Spec No.Bd.F.8 Page No. 302 and B.7, Page1No.38. SSR I.No.14.06, Sr.No.462 P.No.96(For Fourth Floor) |
| 45 | For Court Building-Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite / quartzite / gneiss metal for R.C.C. canopy as per detailed designs and drawings including steel centering, formwork, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing etc. complete (excluding reinforcement). with fully automatic micro processor based PLC with SCADA enabledreversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Spec. No. Bd.F.8 Page 1 No. 303 and B.7, Page No.38 SSR I.No.26.11, Sr.No.859 P.No.184 (For Parking Floor) |
| 46 | For Court Building-Providing and laying Cast in situ/Ready Mixcement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete.Withfineaggregate (Crushed sand VSI Grade) Spec.No. Bd.F.9 Page 1 No. 303 and B.7, Page No.38.SSR I.No.26.07, Sr.No.857, P.No.184 (For Parking Floor) |
| 47 | For Court Building-Providing and laying Cast in situ/Ready Mixcement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete.Withfineaggregate (Crushed sand VSI Grade) Spec.No. Bd.F.9 Page 1 No. 303 and B.7, Page No.38.SSR I.No.26.07, Sr.No.857, P.No.184 (For First Floor) |
| 48 | For Court Building-Providing and laying Cast in situ/Ready Mixcement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete.Withfineaggregate (Crushed sand VSI Grade) Spec.No. Bd.F.9 Page 1 No. 303 and B.7, Page No.38.SSR I.No.26.07, Sr.No.857, P.No.184 (For Second Floor) |
| 49 | For Court Building-Providing and laying Cast in situ/Ready Mixcement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete.Withfineaggregate (Crushed sand VSI Grade) Spec.No. Bd.F.9 Page 1 No. 303 and B.7, Page No.38.SSR I.No.26.07, Sr.No.857, P.No.184 (For Third Floor) |
| 50 | For Court Building-Providing and laying Cast in situ/Ready Mixcement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete.Withfineaggregate (Crushed sand VSI Grade) Spec.No. Bd.F.9 Page 1 No. 303 and B.7, Page No.38.SSR I.No.26.07, Sr.No.857, P.No.184 (For Fourth Floor) |
| 51 | For Court Building-Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer)etc.complete.Withfineaggregate(Crushed sand VSI Grade) Spec. No. Bd.F.11 Page 1 No. 304 and B.7, Page No. 38.SSR I.No.26.19, Sr.No.861, P.No.185 (For Parking Floor) |
| 52 | For Court Building-Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer)etc.complete.Withfineaggregate(Crushed sand VSI Grade) Spec. No. Bd.F.11 Page 1 No. 304 and B.7, Page No. 38.SSR I.No.26.19, Sr.No.861, P.No.185 (ForFirstFloor) |
| 53 | For Court Building-Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer)etc.complete.Withfineaggregate(Crushed sand VSI Grade) Spec. No. Bd.F.11 Page 1 No. 304 and B.7, Page No. 38.SSR I.No.26.19, Sr.No.861, P.No.185 (For Second Floor) |
| 54 | For Court Building-Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer)etc.complete.Withfineaggregate(Crushed sand VSI Grade) Spec. No. Bd.F.11 Page 1 No. 304 and B.7, Page No. 38.SSR I.No.26.19, Sr.No.861, P.No.185 (For ThirdFloor) |
| 55 | For Court Building-Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer)etc.complete.Withfineaggregate(Crushed sand VSI Grade) Spec. No. Bd.F.11 Page 1 No. 304 and B.7, Page No. 38.SSR I.No.26.19, Sr.No.861, P.No.185 (For FourthFloor) |
| 56 | For Court Building-Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap / quartzite/granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant(Panmixer)etc.complete.Withfineaggregate(Crushed sand VSI Grade) Spec.No.Bd. F. 13 Page No. 305 / I.S. 456 (2000..SSR I.No.26.26, Sr.No.864, P.No.186(For Parking Floor) |
| 57 | For Court Building-Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap / quartzite/granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant(Panmixer)etc.complete.Withfineaggregate(Crushed sand VSI Grade) Spec.No.Bd. F. 13 Page No. 305 / I.S. 456 (2000..SSR I.No.26.26, Sr.No.864, P.No.186(For First Floor) |
| 58 | For Court Building-Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap / quartzite/granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant(Panmixer)etc.complete.Withfineaggregate(Crushed sand VSI Grade) Spec.No.Bd. F. 13 Page No. 305 / I.S. 456 (2000..SSR I.No.26.26, Sr.No.864, P.No.186(For Second Floor) |
| 59 | For Court Building-Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap / quartzite/granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant(Panmixer)etc.complete.Withfineaggregate(Crushed sand VSI Grade) Spec.No.Bd. F. 13 Page No. 305 / I.S. 456 (2000..SSR I.No.26.26, Sr.No.864, P.No.186(For ThirdFloor) |
| 60 | For Court Building-Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap / quartzite/granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant(Panmixer)etc.complete.Withfineaggregate(Crushed sand VSI Grade) Spec.No.Bd. F. 13 Page No. 305 / I.S. 456 (2000..SSR I.No.26.26, Sr.No.864, P.No.186(For FourthFloor) |
| 61 | Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.. Spec.No. Bd.F.17, Page 1 No. 306. SSR I.No.26.33, Sr.No.871, P.No.188 1. Court Building (For Parking Floor) - 198.01 MT2. Compound Wall :- 4.41 MT3. Pump house & Sump well 51000 Lt. :- 2.57 MT4. CC Drain :- 11.87 MT5. Parking Shed For 2 Wheelers - 1.37 MT6. Parking Shed For 4 Wheelers :- 1.887. Retaining Wall 3m:- 36.56 MT8. RCC GATE 5.5m Wide :- 4.64 MT9. Cattle\"s Trap :- 1.01 MT10. security room- 3.76 MT |
| 62 | For Court Building-Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.. Spec.No. Bd.F.17, Page 1 No. 306. SSR I.No.26.33, Sr.No.871, P.No.189 (For First Floor) |
| 63 | For Court Building-Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.. Spec.No. Bd.F.17, Page 1 No. 306. SSR I.No.26.33, Sr.No.871, P.No.190 (For Second Floor) |
| 64 | For Court Building-Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.. Spec.No. Bd.F.17, Page 1 No. 306. SSR I.No.26.33, Sr.No.871, P.No.191 (For Third Floor) |
| 65 | For Court Building-Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.. Spec.No. Bd.F.17, Page 1 No. 306. SSR I.No.26.33, Sr.No.871, P.No.192(For Fourth Floor) |
| 66 | For Court Building-Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete.. Spec. No. Bd.C.2 Page 1 Number 275 SSR I.No.23.01, Sr.No.816, P.No.173 (For Fourth Floor) |
| 67 | For Court Building-Providing structural steel work in trusses, other similar trussed purlins and members with all bracing, gusset plates etc. as per detailed designs and drawings or as directed including cutting, fabricating, hoisting, erecting fixing in position, Making riveted/ bolted/ welded connection and one coat of anticorrosive paint andover it 2 coats of oil painting approved quality and shade etc. complete.Spec.No. Bd.C.8 Page Number 278 SSR I.No.23.04, Sr.No.819, P.No.173 (For Fourth Floor) |
| 68 | For Court Building-Providing expansion joints in R.C.C. framed structure (interior column) with plain premoulded filler 25 mm thick including fixing T.W. battens on both faces and finishing as directed etc. Complete. Spec.No. Bd.K.1 Page 1 Number 359. SSR I.No.30.01, Sr.No.926, P.No.203 (For Parking Floor) |
| 69 | For Court Building-Providing expansion joints in R.C.C. framed structure (interior column) with plain premoulded filler 25 mm thick including fixing T.W. battens on both faces and finishing as directed etc. Complete. Spec.No. Bd.K.1 Page 1 Number 359. SSR I.No.30.01, Sr.No.926, P.No.203 (For First Floor) |
| 70 | For Court Building-Providing expansion joints in R.C.C. framed structure (interior column) with plain premoulded filler 25 mm thick including fixing T.W. battens on both faces and finishing as directed etc. Complete. Spec.No. Bd.K.1 Page 1 Number 359. SSR I.No.30.01, Sr.No.926, P.No.203 (For Second Floor) |
| 71 | For Court Building-Providing expansion joints in R.C.C. framed structure (interior column) with plain premoulded filler 25 mm thick including fixing T.W. battens on both faces and finishing as directed etc. Complete. Spec.No. Bd.K.1 Page 1 Number 359. SSR I.No.30.01, Sr.No.926, P.No.203 (For ThirdFloor) |
| 72 | For Court Building-Providing expansion joints in R.C.C. framed structure (interior column) with plain premoulded filler 25 mm thick including fixing T.W. battens on both faces and finishing as directed etc. Complete. Spec.No. Bd.K.1 Page 1 Number 359. SSR I.No.30.01, Sr.No.926, P.No.203 (For Fourth Floor) |
| 73 | For Court Building-Providing expansion joints in R.C.C. framed structure (exterior Columns) with plain premoulded filler 25 mm thick and 3 mm thick alluminium plate, hold fast, fixingT.W. battens on internal face, finishing etc. complete as directed. Spec.No. Bd.K.1 Page 1 Number 359. SSR I.No.30.02, Sr.No.927, P.No.203 (For Parking Floor) |
| 74 | For Court Building-Providing expansion joints in R.C.C. framed structure (exterior Columns) with plain premoulded filler 25 mm thick and 3 mm thick alluminium plate, hold fast, fixingT.W. battens on internal face, finishing etc. complete as directed. Spec.No. Bd.K.1 Page 1 Number 359. SSR I.No.30.02, Sr.No.927, P.No.204 (For First Floor) |
| 75 | For Court Building-Providing expansion joints in R.C.C. framed structure (exterior Columns) with plain premoulded filler 25 mm thick and 3 mm thick alluminium plate, hold fast, fixingT.W. battens on internal face, finishing etc. complete as directed. Spec.No. Bd.K.1 Page 1 Number 359. SSR I.No.30.02, Sr.No.927, P.No.205(For Second Floor) |
| 76 | For Court Building-Providing expansion joints in R.C.C. framed structure (exterior Columns) with plain premoulded filler 25 mm thick and 3 mm thick alluminium plate, hold fast, fixingT.W. battens on internal face, finishing etc. complete as directed. Spec.No. Bd.K.1 Page 1 Number 359. SSR I.No.30.02, Sr.No.927, P.No.206 (For Third Floor) |
| 77 | For Court Building-Providing expansion joints in R.C.C. framed structure (exterior Columns) with plain premoulded filler 25 mm thick and 3 mm thick alluminium plate, hold fast, fixingT.W. battens on internal face, finishing etc. complete as directed. Spec.No. Bd.K.1 Page 1 Number 359. SSR I.No.30.02, Sr.No.927, P.No.206 (For FourthFloor) |
| 78 | For Court Building-Providing expansion joints in R.C.C. framed structure (at floor level) with premoulded filler 25 mm thick and 3 mm thick aluminium plate as required, bitumen poured filler and fixing T.W. battens on rear faces etc. complete as directed. Spec.No. Bd.K.1 Page 1 Number 359. SSR I.No.30.03, Sr.No.928, P.No.203 (For Parking Floor) |
| 79 | For Court Building-Providing expansion joints in R.C.C. framed structure (at floor level) with premoulded filler 25 mm thick and 3 mm thick aluminium plate as required, bitumen poured filler and fixing T.W. battens on rear faces etc. complete as directed. Spec.No. Bd.K.1 Page 1 Number 359. SSR I.No.30.03, Sr.No.928, P.No.203 (For First Floor) |
| 80 | For Court Building-Providing expansion joints in R.C.C. framed structure (at floor level) with premoulded filler 25 mm thick and 3 mm thick aluminium plate as required, bitumen poured filler and fixing T.W. battens on rear faces etc. complete as directed. Spec.No. Bd.K.1 Page 1 Number 359. SSR I.No.30.03, Sr.No.928, P.No.203 (For SecondFloor) |
| 81 | For Court Building-Providing expansion joints in R.C.C. framed structure (at floor level) with premoulded filler 25 mm thick and 3 mm thick aluminium plate as required, bitumen poured filler and fixing T.W. battens on rear faces etc. complete as directed. Spec.No. Bd.K.1 Page 1 Number 359. SSR I.No.30.03, Sr.No.928, P.No.203 (For Third Floor) |
| 82 | For Court Building-Providing expansion joints in R.C.C. framed structure (at terrace level) with premoulded filler 25 mm thick and3 mm thick aluminium plate as required, bituminous pouredfiller, fixing lead, flashing on upper side and T.W. battens on inner face finishing etc. Complete as directed. Spec.No. Bd.K.1 Page 1 Number 359. SSR I.No.30.04, Sr.No.929, P.No.203 (For Terrace Floor) |
| 83 | For Court Building-Providing fly ash brick masonry with conventional / I.S. type fly ash bricks in C.M. 1:6 in foundation and plinth including bailing out water manually striking joints, racking out joints watering and scaffolding etc. complete..Spec. No. As director by engineer in charge andBDG- 2 and 5. SSR I.No.27.12, Sr.No.899 P.No.198 (For ParkingFloor ) |
| 84 | For Court Building-Providing Autoclaved Aerated Concrete Block masonary of conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in superstructure including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972) Spec. No. As director by engineer incharge and BDG- 2 and 5. SSR I.No.27.15, Sr.No.902 P.No.198 (For ParkingFloor ) |
| 85 | For Court Building-Providing Autoclaved Aerated Concrete Block masonary of conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in superstructure including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972) Spec. No. As director by engineer incharge and BDG- 2 and 5. SSR I.No.27.15, Sr.No.902 P.No.198 (For FirstFloor ) |
| 86 | For Court Building-Providing Autoclaved Aerated Concrete Block masonary of conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in superstructure including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972) Spec. No. As director by engineer incharge and BDG- 2 and 5. SSR I.No.27.15, Sr.No.902 P.No.198 (For Second Floor ) |
| 87 | For Court Building-Providing Autoclaved Aerated Concrete Block masonary of conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in superstructure including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972) Spec. No. As director by engineer incharge and BDG- 2 and 5. SSR I.No.27.15, Sr.No.902 P.No.198 (For Third Floor) |
| 88 | For Court Building-Providing Autoclaved Aerated Concrete Block masonary of conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in superstructure including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972) Spec. No. As director by engineer incharge and BDG- 2 and 5. SSR I.No.27.15, Sr.No.902 P.No.198 (For Fourth Floor) |
| 89 | For Court Building-Providing Autoclaved Aerated Concrete Block masonary of conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in Half brick thick wall including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972) Spec. No. Bd. G. 7 Page 316. SSR I.No.27.16, Sr.No.903 P.No.198 (For Parking Floor) |
| 90 | For Court Building-Providing Autoclaved Aerated Concrete Block masonary of conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in Half brick thick wall including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972) Spec. No. Bd. G. 7 Page 316. SSR I.No.27.16, Sr.No.903 P.No.198 (For First Floor) |
| 91 | For Court Building-Providing Autoclaved Aerated Concrete Block masonary of conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in Half brick thick wall including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972) Spec. No. Bd. G. 7 Page 316. SSR I.No.27.16, Sr.No.903 P.No.198 (For SecondFloor) |
| 92 | For Court Building-Providing Autoclaved Aerated Concrete Block masonary of conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in Half brick thick wall including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972) Spec. No. Bd. G. 7 Page 316. SSR I.No.27.16, Sr.No.903 P.No.198 (For ThirdFloor) |
| 93 | For Court Building-Providing Autoclaved Aerated Concrete Block masonary of conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in Half brick thick wall including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972) Spec. No. Bd. G. 7 Page 316. SSR I.No.27.16, Sr.No.903 P.No.198 (For FourthFloor) |
| 94 | For Court Building-Providing and applying water proofing treatment using acrylic polymer modified cement based water proofing coating with fibre glass mesh mixing at the rate of powder to liquid (2:1) by weight covering 9 to 10 Square Metre /Kilogram with two coat using approved chemicals for masonry and concrete surface by brush covering 7 years guarantee on Stamp Papers etc. complete. Spec. No. : As directed by Engineer in charge. SSR I.No.31.09, Sr.No.945, P.No.206 (For Parking Floor) |
| 95 | For Court Building-Providing and applying water proofing treatment using acrylic polymer modified cement based water proofing coating with fibre glass mesh mixing at the rate of powder to liquid (2:1) by weight covering 9 to 10 Square Metre /Kilogram with two coat using approved chemicals for masonry and concrete surface by brush covering 7 years guarantee on Stamp Papers etc. complete. Spec. No. : As directed by Engineer in charge. SSR I.No.31.09, Sr.No.945, P.No.206 (For Fourth Floor) |
| 96 | For Court Building-Providing water proof bedding for flooring of Bath and WC 25 mm thick in C.M. 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete.Spec.No.: As directed, by the Engineer in charge. SSR I.No.31.05, Sr.No.941 P.No.205(For First Floor ) |
| 97 | For Court Building-Providing water proof bedding for flooring of Bath and WC 25 mm thick in C.M. 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete.Spec.No.: As directed, by the Engineer in charge. SSR I.No.31.05, Sr.No.941 P.No.206(For Second Floor) |
| 98 | For Court Building-Providing water proof bedding for flooring of Bath and WC 25 mm thick in C.M. 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete.Spec.No.: As directed, by the Engineer in charge. SSR I.No.31.05, Sr.No.941 P.No.207 (For Third Floor) |
| 99 | For Court Building-Providing water proof bedding for flooring of Bath and WC 25 mm thick in C.M. 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete.Spec.No.: As directed, by the Engineer in charge. SSR I.No.31.05, Sr.No.941 P.No.208 (For Fourth Floor) |
| 100 | Providing and applying two coats of High Albedo paint having minimum Solar Reflective Index (SRI) 108 (with solar reflectance & thermal emittance tested as per ASTM) C 1549 and ASTM C 1371 respectively, VOC less than 10 cc/gm. The coating thickness and the methodology of application shall strctly as per manufacturer\"s specifitions and as approved by engineer in charge. Surface preparation includes cleaning with metal wire brush to remove all dust, fungus etc, washing with water all complete.The contractor shall give guarantee for the performance of SRI and also the durabitity of coating,allcompleteasperdirectionof Engineer - in- incharge.. Spec. No. : As directed by Engineer in charge. SSR I.No.48.19, Sr.No.1637 P.No.313 (SSR 2022-23 GREEN BUILDING) 1. For Court Building (For Parking Floor) - 29.64 sqm2. security room 56.56 sqm |
| 101 | For Court Building-Providing and applying two coats of High Albedo paint having minimum Solar Reflective Index (SRI) 108 (with solar reflectance & thermal emittance tested as per ASTM) C 1549 and ASTM C 1371 respectively, VOC less than 10 cc/gm. The coating thickness and the methodology of application shall strctly as per manufacturer\"s specifitions and as approved by engineer in charge. Surface preparation includes cleaning with metal wire brush to remove all dust, fungus etc, washing with water all complete.The contractor shall give guarantee for the performance of SRI and also the durabitity of coating,allcompleteasperdirectionof Engineer - in- incharge.. Spec. No. : As directed by Engineer in charge. SSR I.No.48.19, Sr.No.1637 P.No.313 (SSR 2022-23 GREEN BUILDING)(For FourthFloor) |
| 102 | For Court Building-Providing and fixing 20 to 25 mm thick rough shahabad box type waterproofing for basement or underground floor on a base of Cement concrete 1:3:6, including sub base of 2.50 centimeter thick Cement mortar 1:3 with conceal, secrete (RMW), Algae proof or other alike waterproofing liquids, raking of joints upto 35 mm depth, filling the joints with 6 mm size crushed metal, hand grouting with cement slurry, curing and cleaning, with 7 years guarantee on court fee stamp of Rs. 100/- with ponding test etc (complete. (excluding Cement concrete 1:3:6 base concrete ) Spec. No. : Bd.J.2 Page 1 Number 355. SSR I.No.31.12, Sr.No.948, P.No.206 (For Parking Floor) |
| 103 | For Court Building-Providing and fixing 20 to 25 mm thick rough shahabad box type waterproofing treatment to vertical outside faces of Reinforced Cement concrete walls of basement or underground floor including filling the gap of 25 mm between rough shahabad and R.C.C. walls with cement grout mixed with water proofing liquid Algae proof or other alike with one tile lift method, brushing the joints horizontally with cement slurry mixed with water proofing liquid for width 30 to 35 mm and sloping coping over topmost tile with cement mortar 1:3, butting the bottom most with Cement concrete 1:2:4 mixed with water proofing liquid, curing, with 7 years guarantee on court fee stamp of Rs.100/- with ponding testetccomplete.(excluding Cement concrete 1:3:6 base concrete) Spec. No. : Bd.J.2 Page 1 Number 355. SSR I.No.31.13, Sr.No.949, P.No.207 (For Parking Floor) |
| 104 | For Court Building-Providing and applying plaster / wall punning with plaster of paris ( with plaster of paris material) in 10 to 13 millimeter thickness to previously plastered surface / or on newly brick surface ( Excluding rough cast plaster ) in all position including preparing and Finishing the surface scaffolding etc.complete.Spec. No. : Bd.L.4 Page 1 No. 368. SSR I.No.32.30, Sr.No.981, P.No.211 (For First Floor) |
| 105 | For Court Building-Providing and applying plaster / wall punning with plaster of paris ( with plaster of paris material) in 10 to 13 millimeter thickness to previously plastered surface / or on newly brick surface ( Excluding rough cast plaster ) in all position including preparing and Finishing the surface scaffolding etc.complete.Spec. No. : Bd.L.4 Page 1 No. 368. SSR I.No.32.30, Sr.No.981, P.No.211 (For Second Floor) |
| 106 | For Court Building-Providing and applying plaster / wall punning with plaster of paris ( with plaster of paris material) in 10 to 13 millimeter thickness to previously plastered surface / or on newly brick surface ( Excluding rough cast plaster ) in all position including preparing and Finishing the surface scaffolding etc.complete.Spec. No. : Bd.L.4 Page 1 No. 368. SSR I.No.32.30, Sr.No.981, P.No.211 (For ThirdFloor) |
| 107 | For Court Building-Providing and applying plaster / wall punning with plaster of paris ( with plaster of paris material) in 10 to 13 millimeter thickness to previously plastered surface / or on newly brick surface ( Excluding rough cast plaster ) in all position including preparing and Finishing the surface scaffolding etc.complete.Spec. No. : Bd.L.4 Page 1 No. 368. SSR I.No.32.30, Sr.No.981, P.No.211 (For FourthFloor) |
| 108 | For Court Building-Providing internal cement plaster 12mm thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete Spec. No. : Bd.L.4 Page 1 No. 368. SSR I.No.32.03, Sr.No.957, P.No.209(For Parking Floor) |
| 109 | For Court Building-Providing internal cement plaster 12mm thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete Spec. No. : Bd.L.4 Page 1 No. 368. SSR I.No.32.03, Sr.No.957, P.No.210(For First Floor) |
| 110 | For Court Building-Providing internal cement plaster 12mm thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete Spec. No. : Bd.L.4 Page 1 No. 368. SSR I.No.32.03, Sr.No.957, P.No.211(For Second Floor) |
| 111 | For Court Building-Providing internal cement plaster 12mm thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete Spec. No. : Bd.L.4 Page 1 No. 368. SSR I.No.32.03, Sr.No.957, P.No.212(For Third Floor) |
| 112 | For Court Building-Providing internal cement plaster 12mm thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete Spec. No. : Bd.L.4 Page 1 No. 368. SSR I.No.32.03, Sr.No.957, P.No.213(For FourthFloor ) |
| 113 | For Court Building-Providing internal cement plaster 20mm thick in Single coats in cement mortar 1:5 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete Spec. No. : Bd.L.4 Page 1 No. 368. SSR I.No.32.06, Sr.No.960, P.No.209 (For Parking Floor) |
| 114 | For Court Building-Providing internal cement plaster 20mm thick in Single coats in cement mortar 1:5 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete Spec. No. : Bd.L.4 Page 1 No. 368. SSR I.No.32.06, Sr.No.960, P.No.209 (For FirstFloor) |
| 115 | For Court Building-Providing internal cement plaster 20mm thick in Single coats in cement mortar 1:5 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete Spec. No. : Bd.L.4 Page 1 No. 368. SSR I.No.32.06, Sr.No.960, P.No.209 (For Second Floor) |
| 116 | Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grainsandcuringforfourteendays scaffolding etc.complete. Spec. No. : Bd.L.7 Page 1 No. 369. SSR I.No.32.11, Sr.No.963, P.No.209 1. Court Building- ( For Parking Floor) 3202.84 sqm2. Compound Wall :- 1476.29 sqm3. Pump house & Sump well 51000 Lt. :-59.62 sqm4. RCC GATE 5.5m Wide 131.38 sqm 5. security room- 281.43 sqm |
| 117 | For Court Building-Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grainsandcuringforfourteendays scaffolding etc.complete. Spec. No. : Bd.L.7 Page 1 No. 369. SSR I.No.32.11, Sr.No.963, P.No.209( For First Floor) |
| 118 | For Court Building-Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grainsandcuringforfourteendays scaffolding etc.complete. Spec. No. : Bd.L.7 Page 1 No. 369. SSR I.No.32.11, Sr.No.963, P.No.209 (For Second Floor) |
| 119 | For Court Building-Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grainsandcuringforfourteendays scaffolding etc.complete. Spec. No. : Bd.L.7 Page 1 No. 369. SSR I.No.32.11, Sr.No.963, P.No.209 (For Third Floor) |
| 120 | For Court Building-Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grainsandcuringforfourteendays scaffolding etc.complete. Spec. No. : Bd.L.7 Page 1 No. 369. SSR I.No.32.11, Sr.No.963, P.No.209( For Fourth Floor) |
| 121 | For Court Building-Providing and applying Texture plaster with finishing with texture material of approved make in 3 to 4 millimeter thickness on previously plastered surface, including Plaster Groove 6mm thickness or Tape Grooves 35 to 45 mm thickness or as required,inallposition including preparing the surface, scaffolding etc. complete. Spec. No. : Bd.L.7 Page 1 No. 369. SSR I.No.32.32, Sr.No.983, P.No.211 (For Parking Floor) |
| 122 | For Court Building-Providing and applying Texture plaster with finishing with texture material of approved make in 3 to 4 millimeter thickness on previously plastered surface, including Plaster Groove 6mm thickness or Tape Grooves 35 to 45 mm thickness or as required,inallposition including preparing the surface, scaffolding etc. complete. Spec. No. : Bd.L.7 Page 1 No. 369. SSR I.No.32.32, Sr.No.983, P.No.211 (For First Floor) |
| 123 | For Court Building-Providing and applying Texture plaster with finishing with texture material of approved make in 3 to 4 millimeter thickness on previously plastered surface, including Plaster Groove 6mm thickness or Tape Grooves 35 to 45 mm thickness or as required,inallposition including preparing the surface, scaffolding etc. complete. Spec. No. : Bd.L.7 Page 1 No. 369. SSR I.No.32.32, Sr.No.983, P.No.211 (For Second Floor) |
| 124 | For Court Building-Providing and applying Texture plaster with finishing with texture material of approved make in 3 to 4 millimeter thickness on previously plastered surface, including Plaster Groove 6mm thickness or Tape Grooves 35 to 45 mm thickness or as required,inallposition including preparing the surface, scaffolding etc. complete. Spec. No. : Bd.L.7 Page 1 No. 369. SSR I.No.32.32, Sr.No.983, P.No.211 (For Third Floor) |
| 125 | For Court Building-Providing and applying Texture plaster with finishing with texture material of approved make in 3 to 4 millimeter thickness on previously plastered surface, including Plaster Groove 6mm thickness or Tape Grooves 35 to 45 mm thickness or as required,inallposition including preparing the surface, scaffolding etc. complete. Spec. No. : Bd.L.7 Page 1 No. 369. SSR I.No.32.32, Sr.No.983, P.No.211 (For Fourth Floor) |
| 126 | For Court Building-Providing and Fixing Processed Stone Cladding on wall surface/ plywood surface. RCC pardi/ Wall and all type of Interior, Exterior Compound wall and Gate etc. of cladding processed stone with material of Processed clay, Wooden chips, Silica sand, Cement, GFRC admixtures, Colour pigments, Fiber up to thick of 230 mm/ 25 mm including scaffolding, fixing of screw, etc. (As directed by Engineer in Charge) Spec. No. : As directed by Engineer-in-charge. SSR I.No.51.192, Sr.No.2031, P.No.409 (For Parking Floor) |
| 127 | For Court Building-Providing and Fixing Processed Stone Cladding on wall surface/ plywood surface. RCC pardi/ Wall and all type of Interior, Exterior Compound wall and Gate etc. of cladding processed stone with material of Processed clay, Wooden chips, Silica sand, Cement, GFRC admixtures, Colour pigments, Fiber up to thick of 230 mm/ 25 mm including scaffolding, fixing of screw, etc. (As directed by Engineer in Charge) Spec. No. : As directed by Engineer-in-charge. SSR I.No.51.192, Sr.No.2031, P.No.409(For First Floor) |
| 128 | For Court Building-Providing and Fixing Processed Stone Cladding on wall surface/ plywood surface. RCC pardi/ Wall and all type of Interior, Exterior Compound wall and Gate etc. of cladding processed stone with material of Processed clay, Wooden chips, Silica sand, Cement, GFRC admixtures, Colour pigments, Fiber up to thick of 230 mm/ 25 mm including scaffolding, fixing of screw, etc. (As directed by Engineer in Charge) Spec. No. : As directed by Engineer-in-charge. SSR I.No.51.192, Sr.No.2031, P.No.409 (For Second Floor) |
| 129 | For Court Building-Providing fine cement finish 1.5 mm thick over green plaster surface including scaffolding curing etc. complete. . Spec. No. : As directed by Engineer in charge. SSR I.No.32.21, Sr.No.972, P.No.210 (For Parking Floor) |
| 130 | For Court Building-Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete. Spec No.: As directed by Engineer in charge. SSR I.No.32.26, Sr.No.977, P.No.210(For Parking Floor) |
| 131 | For Court Building-Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete. Spec No.: As directed by Engineer in charge. SSR I.No.32.26, Sr.No.977, P.No.210(For First Floor) |
| 132 | For Court Building-Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete. Spec No.: As directed by Engineer in charge. SSR I.No.32.26, Sr.No.977, P.No.210( For Second Floor) |
| 133 | For Court Building-Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete. Spec No.: As directed by Engineer in charge. SSR I.No.32.26, Sr.No.977, P.No.210 (For Third Floor) |
| 134 | For Court Building-Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete. Spec No.: As directed by Engineer in charge. SSR I.No.32.26, Sr.No.977, P.No.210 (For Fourth Floor) |
| 135 | Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete.. Spec No.: As directed by Engineer in charge.SSR I.No.32.34, Sr.No.985, P.No.212 1. Court Building- 3101.49 cum 2. Security room - 36 cum 3. Pump house & Sump well 51000 Lt.- 13.63 cum |
| 136 | For Court Building-Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete.. Spec No.: As directed by Engineer in charge.SSR I.No.32.34, Sr.No.985, P.No.212( For First Floor) |
| 137 | For Court Building-Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete.. Spec No.: As directed by Engineer in charge.SSR I.No.32.34, Sr.No.985, P.No.212(For Second Floor) |
| 138 | For Court Building-Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete.. Spec No.: As directed by Engineer in charge.SSR I.No.32.34, Sr.No.985, P.No.212( ForThird Floor) |
| 139 | For Court Building-Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete.. Spec No.: As directed by Engineer in charge.SSR I.No.32.34, Sr.No.985, P.No.212 (For Fourth Floor) |
| 140 | For Court Building-Providing and fixing false ceiling with eco-friendly light-weight calcium silicatetiles of spintone surface texture aerolite make or equivalent of size 595mm x 595mm having 15mm thick densified micro look edge and 100% humidity resistance incombustible as per BS 46part IV and thermal conductivity 0.043 w/m 0 KC and NRC 0.50 placed in true horizontal level suspended grid of size 600x600mm made from hot dipped G.I. steel sections ion silhouette profile, rotary stitched double webbed white with 6mm reveal profile (white/black), wherein, main T runner of size 42mmx14mm between main tee 600mm center-tocenter and secondary cross T of size 33x14x0.43mm thick of length 600mm long spaced inter-locked at middle of the first crossed T in each panel to form grid of 1200mmx600mm resting on periphery wall Profile wall section 19mm (7+7) x 19mmx0.40thicknesses and laying false ceiling for services like diffusers grills including cutting, making opening for light fittings, fixtures, , smoke detectors etc., wherever required. Main T runners suspended from ceiling with using G.I. soffit cleats of size 25x35x1.6 mm of required length fixed to the ceiling with 6mm dia and 50mm long dash fastener, 4mm dia G.I. adjustable rods with powder- coated/good quality G.I. level adjustment clips of35x35x0.8mmspaced@1200,center-tocenter along main T all complete at all heights as per the specifications, drawings and as per Spec.No. As Directed By Engineer in charge.SSR I.No.38.40, Sr.No.1180, P.No.238(For Parking Floor) |
| 141 | For Court Building-Providing and fixing false ceiling with eco-friendly light-weight calcium silicatetiles of spintone surface texture aerolite make or equivalent of size 595mm x 595mm having 15mm thick densified micro look edge and 100% humidity resistance incombustible as per BS 46part IV and thermal conductivity 0.043 w/m 0 KC and NRC 0.50 placed in true horizontal level suspended grid of size 600x600mm made from hot dipped G.I. steel sections ion silhouette profile, rotary stitched double webbed white with 6mm reveal profile (white/black), wherein, main T runner of size 42mmx14mm between main tee 600mm center-tocenter and secondary cross T of size 33x14x0.43mm thick of length 600mm long spaced inter-locked at middle of the first crossed T in each panel to form grid of 1200mmx600mm resting on periphery wall Profile wall section 19mm (7+7) x 19mmx0.40thicknesses and laying false ceiling for services like diffusers grills including cutting, making opening for light fittings, fixtures, , smoke detectors etc., wherever required. Main T runners suspended from ceiling with using G.I. soffit cleats of size 25x35x1.6 mm of required length fixed to the ceiling with 6mm dia and 50mm long dash fastener, 4mm dia G.I. adjustable rods with powder- coated/good quality G.I. level adjustment clips of35x35x0.8mmspaced@1200,center-tocenter along main T all complete at all heights as per the specifications, drawings and as per Spec.No. As Directed By Engineer in charge.SSR I.No.38.40, Sr.No.1180, P.No.238( For First Floor) |
| 142 | For Court Building-Providing and fixing false ceiling with eco-friendly light-weight calcium silicatetiles of spintone surface texture aerolite make or equivalent of size 595mm x 595mm having 15mm thick densified micro look edge and 100% humidity resistance incombustible as per BS 46part IV and thermal conductivity 0.043 w/m 0 KC and NRC 0.50 placed in true horizontal level suspended grid of size 600x600mm made from hot dipped G.I. steel sections ion silhouette profile, rotary stitched double webbed white with 6mm reveal profile (white/black), wherein, main T runner of size 42mmx14mm between main tee 600mm center-tocenter and secondary cross T of size 33x14x0.43mm thick of length 600mm long spaced inter-locked at middle of the first crossed T in each panel to form grid of 1200mmx600mm resting on periphery wall Profile wall section 19mm (7+7) x 19mmx0.40thicknesses and laying false ceiling for services like diffusers grills including cutting, making opening for light fittings, fixtures, , smoke detectors etc., wherever required. Main T runners suspended from ceiling with using G.I. soffit cleats of size 25x35x1.6 mm of required length fixed to the ceiling with 6mm dia and 50mm long dash fastener, 4mm dia G.I. adjustable rods with powder- coated/good quality G.I. level adjustment clips of35x35x0.8mmspaced@1200,center-tocenter along main T all complete at all heights as per the specifications, drawings and as per Spec.No. As Directed By Engineer in charge.SSR I.No.38.40, Sr.No.1180, P.No.238( For Second Floor) |
| 143 | For Court Building-Providing and fixing false ceiling with eco-friendly light-weight calcium silicatetiles of spintone surface texture aerolite make or equivalent of size 595mm x 595mm having 15mm thick densified micro look edge and 100% humidity resistance incombustible as per BS 46part IV and thermal conductivity 0.043 w/m 0 KC and NRC 0.50 placed in true horizontal level suspended grid of size 600x600mm made from hot dipped G.I. steel sections ion silhouette profile, rotary stitched double webbed white with 6mm reveal profile (white/black), wherein, main T runner of size 42mmx14mm between main tee 600mm center-tocenter and secondary cross T of size 33x14x0.43mm thick of length 600mm long spaced inter-locked at middle of the first crossed T in each panel to form grid of 1200mmx600mm resting on periphery wall Profile wall section 19mm (7+7) x 19mmx0.40thicknesses and laying false ceiling for services like diffusers grills including cutting, making opening for light fittings, fixtures, , smoke detectors etc., wherever required. Main T runners suspended from ceiling with using G.I. soffit cleats of size 25x35x1.6 mm of required length fixed to the ceiling with 6mm dia and 50mm long dash fastener, 4mm dia G.I. adjustable rods with powder- coated/good quality G.I. level adjustment clips of35x35x0.8mmspaced@1200,center-tocenter along main T all complete at all heights as per the specifications, drawings and as per Spec.No. As Directed By Engineer in charge.SSR I.No.38.40, Sr.No.1180, P.No.238( For Third Floor) |
| 144 | For Court Building-Providing and fixing false ceiling with eco-friendly light-weight calcium silicatetiles of spintone surface texture aerolite make or equivalent of size 595mm x 595mm having 15mm thick densified micro look edge and 100% humidity resistance incombustible as per BS 46part IV and thermal conductivity 0.043 w/m 0 KC and NRC 0.50 placed in true horizontal level suspended grid of size 600x600mm made from hot dipped G.I. steel sections ion silhouette profile, rotary stitched double webbed white with 6mm reveal profile (white/black), wherein, main T runner of size 42mmx14mm between main tee 600mm center-tocenter and secondary cross T of size 33x14x0.43mm thick of length 600mm long spaced inter-locked at middle of the first crossed T in each panel to form grid of 1200mmx600mm resting on periphery wall Profile wall section 19mm (7+7) x 19mmx0.40thicknesses and laying false ceiling for services like diffusers grills including cutting, making opening for light fittings, fixtures, , smoke detectors etc., wherever required. Main T runners suspended from ceiling with using G.I. soffit cleats of size 25x35x1.6 mm of required length fixed to the ceiling with 6mm dia and 50mm long dash fastener, 4mm dia G.I. adjustable rods with powder- coated/good quality G.I. level adjustment clips of35x35x0.8mmspaced@1200,center-tocenter along main T all complete at all heights as per the specifications, drawings and as per Spec.No. As Directed By Engineer in charge.SSR I.No.38.40, Sr.No.1180, P.No.238 ( For Fourth Floor) |
| 145 | For Court Building-Providing groove to required size at specified location as directed by Engineer, at junction of brick masonry wall and R.C.C beams or Column, at junction of composite masonry, including scaffolding, finishing, curing etc. complete. Spec. No. As directed by Engineer in charge. SSR I.No.32.37, Sr.No.987, P.No.212 (For Parking Floor) |
| 146 | For Court Building-Providing groove to required size at specified location as directed by Engineer, at junction of brick masonry wall and R.C.C beams or Column, at junction of composite masonry, including scaffolding, finishing, curing etc. complete. Spec. No. As directed by Engineer in charge. SSR I.No.32.37, Sr.No.987, P.No.212(For First Floor) |
| 147 | For Court Building-Providing groove to required size at specified location as directed by Engineer, at junction of brick masonry wall and R.C.C beams or Column, at junction of composite masonry, including scaffolding, finishing, curing etc. complete. Spec. No. As directed by Engineer in charge. SSR I.No.32.37, Sr.No.987, P.No.212 (For Second Floor) |
| 148 | For Court Building-Providing groove to required size at specified location as directed by Engineer, at junction of brick masonry wall and R.C.C beams or Column, at junction of composite masonry, including scaffolding, finishing, curing etc. complete. Spec. No. As directed by Engineer in charge. SSR I.No.32.37, Sr.No.987, P.No.212 (For Third Floor) |
| 149 | For Court Building-Providing groove to required size at specified location as directed by Engineer, at junction of brick masonry wall and R.C.C beams or Column, at junction of composite masonry, including scaffolding, finishing, curing etc. complete. Spec. No. As directed by Engineer in charge. SSR I.No.32.37, Sr.No.987, P.No.212 (For Fourth Floor) |
| 150 | For Court Building-Providing and laying Vitrified MATT finish having decorative type of size 1000 millimeter x 1000millimeter of 8 to 10millimeter thickness, and confirming to IS 15622-2006 (Group Bla) of approvedmake shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete. Spec. Nos. Bd. M-12 page Number 388. SSR I.Nos.33.61 P.Nos.220 Spec. No. Bd.M.12 Page No. 388. SSR I.No.33.61, Sr.No.1047 P.No.220 (For First Floor) |
| 151 | For Court Building-Providing and laying Vitrified MATT finish having decorative type of size 1000 millimeter x 1000millimeter of 8 to 10millimeter thickness, and confirming to IS 15622-2006 (Group Bla) of approvedmake shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete. Spec. Nos. Bd. M-12 page Number 388. SSR I.Nos.33.61 P.Nos.220 Spec. No. Bd.M.12 Page No. 388. SSR I.No.33.61, Sr.No.1047 P.No.220 (For Second Floor) |
| 152 | For Court Building-Providing and laying Vitrified MATT finish having decorative type of size 1000 millimeter x 1000For Court Building-millimeter of 8 to 10millimeter thickness, and confirming to IS 15622-2006 (Group Bla) of approvedmake shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete. Spec. Nos. Bd. M-12 page Number 388. SSR I.Nos.33.61 P.Nos.220 Spec. No. Bd.M.12 Page No. 388. SSR I.No.33.61, Sr.No.1047 P.No.220(For Third Floor) |
| 153 | For Court Building-Providing and laying Vitrified MATT finish having decorative type of size 1000 millimeter x 1000millimeter of 8 to 10millimeter thickness, and confirming to IS 15622-2006 (Group Bla) of approvedmake shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete. Spec. Nos. Bd. M-12 page Number 388. SSR I.Nos.33.61 P.Nos.220 Spec. No. Bd.M.12 Page No. 388. SSR I.No.33.61, Sr.No.1047 P.No.220(For Fourth Floor) |
| 154 | For Court Building-Providing and laying vitrified rustic matt stone finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10mm thickness and confirming to IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. Spec. No. Bd.M.12 Page No. 385. SSR I.No.33.44, Sr.No.1031 P.No.217(For Parking Floor) |
| 155 | For Court Building-Providing and laying vitrified rustic matt stone finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10mm thickness and confirming to IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. Spec. No. Bd.M.12 Page No. 385. SSR I.No.33.44, Sr.No.1031 P.No.217(ForFirstFloor) |
| 156 | For Court Building-Providing and laying vitrified rustic matt stone finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10mm thickness and confirming to IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. Spec. No. Bd.M.12 Page No. 385. SSR I.No.33.44, Sr.No.1031 P.No.217(ForSecondFloor) |
| 157 | For Court Building-Providing and laying vitrified rustic matt stone finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10mm thickness and confirming to IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. Spec. No. Bd.M.12 Page No. 385. SSR I.No.33.44, Sr.No.1031 P.No.217(ForThird Floor) |
| 158 | For Court Building-Providing and laying vitrified rustic matt stone finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10mm thickness and confirming to IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. Spec. No. Bd.M.12 Page No. 385. SSR I.No.33.44, Sr.No.1031 P.No.217(ForFourth Floor) |
| 159 | For Court Building-Providing and laying vitrified rustic matt stone finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm to 8 to 10mm thickness and confirming to IS. 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and cleaning. etc. complete. Spec. No. Bd.M.12 Page 1 No. 385. SSR I.No.33.45, Sr.No.1032 P.No.218 (For Parking Floor) |
| 160 | For Court Building-Providing and laying vitrified rustic matt stone finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm to 8 to 10mm thickness and confirming to IS. 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and cleaning. etc. complete. Spec. No. Bd.M.12 Page 1 No. 385. SSR I.No.33.45, Sr.No.1032 P.No.218 (For FirstFloor) |
| 161 | For Court Building-Providing and laying vitrified rustic matt stone finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm to 8 to 10mm thickness and confirming to IS. 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and cleaning. etc. complete. Spec. No. Bd.M.12 Page 1 No. 385. SSR I.No.33.45, Sr.No.1032 P.No.218 (For Second Floor) |
| 162 | For Court Building-Providing and laying vitrified rustic matt stone finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm to 8 to 10mm thickness and confirming to IS. 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and cleaning. etc. complete. Spec. No. Bd.M.12 Page 1 No. 385. SSR I.No.33.45, Sr.No.1032 P.No.218 (For Third Floor) |
| 163 | For Court Building-Providing and laying vitrified rustic matt stone finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm to 8 to 10mm thickness and confirming to IS. 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and cleaning. etc. complete. Spec. No. Bd.M.12 Page 1 No. 385. SSR I.No.33.45, Sr.No.1032 P.No.218 (For Fourth Floor) |
| 164 | For Court Building-Providing and fixing heavy duty inter locking concrete Coloured paving blocks of 80 mm thickness of having a strength of 300 Kilogram/Sq.cm. of approved quality and shape on a bed of crushed sand of 25 to 30 mm thick including skirting joints and cleaning etc.complete Spec. Nos. : As directed by Engineer in charge. SSR I.Nos.33.52, Sr.Nos.1039, P.Nos.218(For Parking Floor) |
| 165 | For Court Building-Providing and laying vitrified matt finish tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc.complete.Spec. No. Bd.M.12 Page 1 No. 385. SSR I.No.33.43, Sr.No.1030 P.No.217(For Parking Floor) |
| 166 | For Court Building-Providing and laying vitrified matt finish tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc.complete.Spec. No. Bd.M.12 Page 1 No. 385. SSR I.No.33.43, Sr.No.1030 P.No.217(For First Floor) |
| 167 | For Court Building-Providing and laying vitrified matt finish tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc.complete.Spec. No. Bd.M.12 Page 1 No. 385. SSR I.No.33.43, Sr.No.1030 P.No.217(For Second Floor) |
| 168 | For Court Building-Providing and laying vitrified matt finish tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc.complete.Spec. No. Bd.M.12 Page 1 No. 385. SSR I.No.33.43, Sr.No.1030 P.No.217 (For Third Floor) |
| 169 | For Court Building-Providing and laying vitrified matt finish tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc.complete.Spec. No. Bd.M.12 Page 1 No. 385. SSR I.No.33.43, Sr.No.1030 P.No.217 (For Fourth Floor) |
| 170 | For Court Building-Providing and laying vitrified matt fininsh tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete.Spec. No.Bd.M.12 Page One Number 385. SSR I.No.33.42, Sr.No.1028 P.No.217 (For Parking Floor) |
| 171 | For Court Building-Providing and laying vitrified matt fininsh tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete.Spec. No.Bd.M.12 Page One Number 385. SSR I.No.33.42, Sr.No.1028 P.No.217 (For First Floor) |
| 172 | For Court Building-Providing and laying vitrified matt fininsh tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete.Spec. No.Bd.M.12 Page One Number 385. SSR I.No.33.42, Sr.No.1028 P.No.217 (For Second Floor) |
| 173 | For Court Building-Providing and laying vitrified matt fininsh tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete.Spec. No.Bd.M.12 Page One Number 385. SSR I.No.33.42, Sr.No.1028 P.No.217 ((For Third Floor) |
| 174 | For Court Building-Providing and laying vitrified matt fininsh tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete.Spec. No.Bd.M.12 Page One Number 385. SSR I.No.33.42, Sr.No.1028 P.No.217 (For Fourth Floor) |
| 175 | For Court Building-Providing and laying machine cut machine Polished Kota stone flooring 25mm to 30mm thick and required width in plain/ diamond pattern on bed of 1:6 C. M. including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete.. Spec. No. Bd.M.3 Page 1 No.380.SSR I.No.33.06, Sr.No.993 P.No.213(For Parking Floor) |
| 176 | For Court Building-Providing and laying machine cut machine Polished Kota stone flooring 25mm to 30mm thick and required width in plain/ diamond pattern on bed of 1:6 C. M. including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete.. Spec. No. Bd.M.3 Page 1 No.380.SSR I.No.33.06, Sr.No.993 P.No.213 (For First Floor) |
| 177 | For Court Building-Providing and laying machine cut machine Polished Kota stone flooring 25mm to 30mm thick and required width in plain/ diamond pattern on bed of 1:6 C. M. including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete.. Spec. No. Bd.M.3 Page 1 No.380.SSR I.No.33.06, Sr.No.993 P.No.213 (For Second Floor) |
| 178 | For Court Building-Providing and laying machine cut machine Polished Kota stone flooring 25mm to 30mm thick and required width in plain/ diamond pattern on bed of 1:6 C. M. including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete.. Spec. No. Bd.M.3 Page 1 No.380.SSR I.No.33.06, Sr.No.993 P.No.213(For Third Floor) |
| 179 | For Court Building-Providing and laying machine cut machine Polished Kota stone flooring 25mm to 30mm thick and required width in plain/ diamond pattern on bed of 1:6 C. M. including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete.. Spec. No. Bd.M.3 Page 1 No.380.SSR I.No.33.06, Sr.No.993 P.No.213 (For Fourth Floor) |
| 180 | Providing Mirror polishing to Kota Stone including using all necessary stones and equipments cleaning, washingetc. complete. For Flooring Spec. No. As directed by Engineer in charge. SSR I.No.33.28, Sr.No.1015 P.No.216(For Parking Floor) 1. Court Building - 87.3 sqm 2. Security room - 6. sqm |
| 181 | For Court Building-Providing Mirror polishing to Kota Stone including using all necessary stones and equipments cleaning, washingetc. complete. For Flooring Spec. No. As directed by Engineer in charge. SSR I.No.33.28, Sr.No.1015 P.No.217 (For First Floor) |
| 182 | For Court Building-Providing Mirror polishing to Kota Stone including using all necessary stones and equipments cleaning, washingetc. complete. For Flooring Spec. No. As directed by Engineer in charge. SSR I.No.33.28, Sr.No.1015 P.No.218 (For Second Floor) |
| 183 | For Court Building-Providing Mirror polishing to Kota Stone including using all necessary stones and equipments cleaning, washingetc. complete. For Flooring Spec. No. As directed by Engineer in charge. SSR I.No.33.28, Sr.No.1015 P.No.219 (For Third Floor) |
| 184 | For Court Building-Providing Mirror polishing to Kota Stone including using all necessary stones and equipments cleaning, washingetc. complete. For Flooring Spec. No. As directed by Engineer in charge. SSR I.No.33.28, Sr.No.1015 P.No.220 (For Fourth Floor) |
| 185 | For Court Building-Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete... Spec. No. Bd.M. 3 B/Page Number 380. SSR I.No.33.34, Sr.No.1021 P.No.216(For Parking Floor) |
| 186 | For Court Building-Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete... Spec. No. Bd.M. 3 B/Page Number 380. SSR I.No.33.34, Sr.No.1021 P.No.216(For First Floor) |
| 187 | For Court Building-Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete... Spec. No. Bd.M. 3 B/Page Number 380. SSR I.No.33.34, Sr.No.1021 P.No.216(ForSecondFloor) |
| 188 | For Court Building-Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete... Spec. No. Bd.M. 3 B/Page Number 380. SSR I.No.33.34, Sr.No.1021 P.No.216(For ThirdFloor) |
| 189 | For Court Building-Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete... Spec. No. Bd.M. 3 B/Page Number 380. SSR I.No.33.34, Sr.No.1021 P.No.216(For Fourth Floor) |
| 190 | For Court Building-Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling jointswithneatcement slurry curing polishing and cleaningetc. complete. Spec No.:Bd. M.22 B/Page Number 390. SSR I.No.33.35, Sr.No.1022, P.216(For Parking Floor) |
| 191 | For Court Building-Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling jointswithneatcement slurry curing polishing and cleaningetc. complete. Spec No.:Bd. M.22 B/Page Number 390. SSR I.No.33.35, Sr.No.1022, P.216(For First Floor) |
| 192 | For Court Building-Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling jointswithneatcement slurry curing polishing and cleaningetc. complete. Spec No.:Bd. M.22 B/Page Number 390. SSR I.No.33.35, Sr.No.1022, P.216(For Second Floor) |
| 193 | For Court Building-Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling jointswithneatcement slurry curing polishing and cleaningetc. complete. Spec No.:Bd. M.22 B/Page Number 390. SSR I.No.33.35, Sr.No.1022, P.216(For Third Floor) |
| 194 | For Court Building-Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling jointswithneatcement slurry curing polishing and cleaningetc. complete. Spec No.:Bd. M.22 B/Page Number 390. SSR I.No.33.35, Sr.No.1022, P.216(For Fourth Floor) |
| 195 | For Court Building-Providing leather finished polishing to Granite Stone slab by continuous grinding in 4 coats of different bits to receive rough and matt finish including buffing process before laying and fixing of stone as per drawing and design, including cleaning, washing andfinishingetc. complete.. SSR I.Nos.33.56, Sr.Nos.1043 P.Nos.219(For GroundFloor) |
| 196 | For Court Building-Providing leather finished polishing to Granite Stone slab by continuous grinding in 4 coats of different bits to receive rough and matt finish including buffing process before laying and fixing of stone as per drawing and design, including cleaning, washing andfinishingetc. complete.. SSR I.Nos.33.56, Sr.Nos.1043 P.Nos.219(For First Floor) |
| 197 | For Court Building-Providing leather finished polishing to Granite Stone slab by continuous grinding in 4 coats of different bits to receive rough and matt finish including buffing process before laying and fixing of stone as per drawing and design, including cleaning, washing andfinishingetc. complete.. SSR I.Nos.33.56, Sr.Nos.1043 P.Nos.219(For Second Floor) |
| 198 | For Court Building-Providing leather finished polishing to Granite Stone slab by continuous grinding in 4 coats of different bits to receive rough and matt finish including buffing process before laying and fixing of stone as per drawing and design, including cleaning, washing andfinishingetc. complete.. SSR I.Nos.33.56, Sr.Nos.1043 P.Nos.219(For Third Floor) |
| 199 | For Court Building-Providing leather finished polishing to Granite Stone slab by continuous grinding in 4 coats of different bits to receive rough and matt finish including buffing process before laying and fixing of stone as per drawing and design, including cleaning, washing andfinishingetc. complete.. SSR I.Nos.33.56, Sr.Nos.1043 P.Nos.219(For Fourth Floor) |
| 200 | For Court Building-Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing,etc. complete..Spec. No. As directed by Engineer-In- Charge. SSR I.No.33.68, Sr.No.1052 P.No.220(For Parking Floor) |
| 201 | For Court Building-Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing,etc. complete..Spec. No. As directed by Engineer-In- Charge. SSR I.No.33.68, Sr.No.1052 P.No.220(For First Floor) |
| 202 | For Court Building-Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing,etc. complete..Spec. No. As directed by Engineer-In- Charge. SSR I.No.33.68, Sr.No.1052 P.No.220(For Second Floor) |
| 203 | For Court Building-Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing,etc. complete..Spec. No. As directed by Engineer-In- Charge. SSR I.No.33.68, Sr.No.1052 P.No.220(For Third Floor) |
| 204 | For Court Building-Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing,etc. complete..Spec. No. As directed by Engineer-In- Charge. SSR I.No.33.68, Sr.No.1052 P.No.220(For Fourth Floor) |
| 205 | For Court Building-Providing and laying chequered tiles of approved quality of size 30 cm x 30 cm, confirming to corresponding I.S. for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete.. Spec No.:Bd. M-12 page Number 385. SSR I.No.33.66, Sr.No.1050, P.220(For Parking Floor) |
| 206 | For Court Building-Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 mm x 450 mm size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 mm thick supports with kadappah top 35 to 40 mm thick and polished granite 16 to 20 mm top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 cm height and top granite of 75 x 40 cm including cutting, opening for sink of required size in kadappah as well as granite etc. complete. (Platform top size 5.00 m x 0.60 m and height is 0.75 m) Spec. No. As directed by Engineer-In- Charge. SSR I.No.41.78, Sr.No.1369 P.No.273 (For First Floor) |
| 207 | For Court Building-Kitchen TrolleyProviding and Fixing stainless steel kitchen trolley of overall 26 \" height and 22\" depth,supported on aluminium pipes ,trolley basket made out of 5 mm stainless steel rod fitted on telescopic channel of size 1.5 \" x 20 \" x 22 \" on both sides of trolley of 12 \" or above size, panel having 40Kilogramload bearing capacity of trolley made out of 20 mm PUC coated plywood and colour combination as directed by E-I-C.Inner side of panel covered by white mica ,100 mm s.s. decorative handle.(The width and height of individual compartments shall be kept as directed by Engineer-in-charge Spec. No. As directed by Engineer-In- Charge. SSR I.No.51.59, Sr.No.1884 P.No.368(For First Floor) |
| 208 | For Court Building-Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete.. Spec. No. : As directed by Engineer in charge. SSR I.No.35.21, Sr.No.1090 P.No.225(For Parking Floor) |
| 209 | For Court Building-Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete.. Spec. No. : As directed by Engineer in charge. SSR I.No.35.21, Sr.No.1090 P.No.225(For First Floor) |
| 210 | For Court Building-Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete.. Spec. No. : As directed by Engineer in charge. SSR I.No.35.21, Sr.No.1090 P.No.225(For Second Floor) |
| 211 | For Court Building-Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete.. Spec. No. : As directed by Engineer in charge. SSR I.No.35.21, Sr.No.1090 P.No.225(For Third Floor) |
| 212 | For Court Building-Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete.. Spec. No. : As directed by Engineer in charge. SSR I.No.35.21, Sr.No.1090 P.No.225(For Fourth Floor) |
| 213 | For Court Building-Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces. (excluding the primer coat.) etc. complete.Spec. No. : Bd.P.5 Page No. 413. SSR I.No.36.11, Sr.No.1106 P.No.227(For Parking Floor) |
| 214 | For Court Building-Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces. (excluding the primer coat.) etc. complete.Spec. No. : Bd.P.5 Page No. 413. SSR I.No.36.11, Sr.No.1106 P.No.227(For First Floor) |
| 215 | For Court Building-Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces. (excluding the primer coat.) etc. complete.Spec. No. : Bd.P.5 Page No. 413. SSR I.No.36.11, Sr.No.1106 P.No.227(For Second Floor) |
| 216 | For Court Building-Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces. (excluding the primer coat.) etc. complete.Spec. No. : Bd.P.5 Page No. 413. SSR I.No.36.11, Sr.No.1106 P.No.227(For Third Floor) |
| 217 | For Court Building-Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces. (excluding the primer coat.) etc. complete.Spec. No. : Bd.P.5 Page No. 413. SSR I.No.36.11, Sr.No.1106 P.No.227(For Fourth Floor) |
| 218 | For Court Building-Providing and applying 2 Coats of high quality acrylic copolymer matt approved low VOC emulsion paint of approved shadethat gives smooth, flat and washable and durable finishing of approved make. Paint should have good flow levelling property with good colour retention and incan antibacterial property. Paint has to be applied on smooth and uniform surface prepared by an acrylic copolymer low VOC & Odour puttyThis Surface should be primed with water based low VOC acrylic copolymer based primesealer that has incan antibacterial property. The work activity should cover all aspects of applying paints from surface preparation, filling to erecting and dismantling of scaffolding,finishingthesurfaceetcas directed by Engineer in charge.. Spec. No. : As directed by Engineer in charge. SSR I.No.48.13, Sr.No.1632, P.No.312 (SSR 2022-23 GREEN BUILDING)(For Parking Floor) |
| 219 | For Court Building-Providing and applying 2 Coats of high quality acrylic copolymer matt approved low VOC emulsion paint of approved shadethat gives smooth, flat and washable and durable finishing of approved make. Paint should have good flow levelling property with good colour retention and incan antibacterial property. Paint has to be applied on smooth and uniform surface prepared by an acrylic copolymer low VOC & Odour puttyThis Surface should be primed with water based low VOC acrylic copolymer based primesealer that has incan antibacterial property. The work activity should cover all aspects of applying paints from surface preparation, filling to erecting and dismantling of scaffolding,finishingthesurfaceetcas directed by Engineer in charge.. Spec. No. : As directed by Engineer in charge. SSR I.No.48.13, Sr.No.1632, P.No.312 (SSR 2022-23 GREEN BUILDING)(For First Floor) |
| 220 | For Court Building-Providing and applying 2 Coats of high quality acrylic copolymer matt approved low VOC emulsion paint of approved shadethat gives smooth, flat and washable and durable finishing of approved make. Paint should have good flow levelling property with good colour retention and incan antibacterial property. Paint has to be applied on smooth and uniform surface prepared by an acrylic copolymer low VOC & Odour puttyThis Surface should be primed with water based low VOC acrylic copolymer based primesealer that has incan antibacterial property. The work activity should cover all aspects of applying paints from surface preparation, filling to erecting and dismantling of scaffolding,finishingthesurfaceetcas directed by Engineer in charge.. Spec. No. : As directed by Engineer in charge. SSR I.No.48.13, Sr.No.1632, P.No.312 (SSR 2022-23 GREEN BUILDING)(For Second Floor) |
| 221 | For Court Building-Providing and applying 2 Coats of high quality acrylic copolymer matt approved low VOC emulsion paint of approved shadethat gives smooth, flat and washable and durable finishing of approved make. Paint should have good flow levelling property with good colour retention and incan antibacterial property. Paint has to be applied on smooth and uniform surface prepared by an acrylic copolymer low VOC & Odour puttyThis Surface should be primed with water based low VOC acrylic copolymer based primesealer that has incan antibacterial property. The work activity should cover all aspects of applying paints from surface preparation, filling to erecting and dismantling of scaffolding,finishingthesurfaceetcas directed by Engineer in charge.. Spec. No. : As directed by Engineer in charge. SSR I.No.48.13, Sr.No.1632, P.No.312 (SSR 2022-23 GREEN BUILDING)(For Third Floor) |
| 222 | For Court Building-Providing and applying 2 Coats of high quality acrylic copolymer matt approved low VOC emulsion paint of approved shadethat gives smooth, flat and washable and durable finishing of approved make. Paint should have good flow levelling property with good colour retention and incan antibacterial property. Paint has to be applied on smooth and uniform surface prepared by an acrylic copolymer low VOC & Odour puttyThis Surface should be primed with water based low VOC acrylic copolymer based primesealer that has incan antibacterial property. The work activity should cover all aspects of applying paints from surface preparation, filling to erecting and dismantling of scaffolding,finishingthesurfaceetcas directed by Engineer in charge.. Spec. No. : As directed by Engineer in charge. SSR I.No.48.13, Sr.No.1632, P.No.312 (SSR 2022-23 GREEN BUILDING)(For Fourth Floor) |
| 223 | Providing and applying 2 Coats of 100% Pure acrylic water based paint with special heat reflectance property to withstand the harsh climate for period of atleast 10 years of approved make. Paint system should provide durable and long lasting finish with DFT of min 90 microns and should protect against concrete carbonation with R value of minimum 600 and equivalent concrete layer thickness value of min 150 cm. Paint should have breathability property and should be able to cover hairline cracks in the surface upto 0.5mm The paint has to be applied on a coat of high quality acrylic copolymer based alkali resistant primer with excellent penetrating properties including cleaning, with all leads and lifts at all levels etc complete, as directed by Engineer in charge..Spec. No. : As directed by Engineer in charge. SSR I.No.48.12, Sr.No.1631, P.No.311 (SSR 2022-23 GREEN BUILDING)(For Parking Floor) 1. For Court Building- 1302.84 sqm 2. Compound Wall :-1476.29 sqm 3. RCC gate 131.38 sqm4. Security room 281.44 sqm |
| 224 | For Court Building-Providing and applying 2 Coats of 100% Pure acrylic water based paint with special heat reflectance property to withstand the harsh climate for period of atleast 10 years of approved make. Paint system should provide durable and long lasting finish with DFT of min 90 microns and should protect against concrete carbonation with R value of minimum 600 and equivalent concrete layer thickness value of min 150 cm. Paint should have breathability property and should be able to cover hairline cracks in the surface upto 0.5mm The paint has to be applied on a coat of high quality acrylic copolymer based alkali resistant primer with excellent penetrating properties including cleaning, with all leads and lifts at all levels etc complete, as directed by Engineer in charge..Spec. No. : As directed by Engineer in charge. SSR I.No.48.12, Sr.No.1631, P.No.311 (SSR 2022-23 GREEN BUILDING)(For First Floor) |
| 225 | For Court Building-Providing and applying 2 Coats of 100% Pure acrylic water based paint with special heat reflectance property to withstand the harsh climate for period of atleast 10 years of approved make. Paint system should provide durable and long lasting finish with DFT of min 90 microns and should protect against concrete carbonation with R value of minimum 600 and equivalent concrete layer thickness value of min 150 cm. Paint should have breathability property and should be able to cover hairline cracks in the surface upto 0.5mm The paint has to be applied on a coat of high quality acrylic copolymer based alkali resistant primer with excellent penetrating properties including cleaning, with all leads and lifts at all levels etc complete, as directed by Engineer in charge..Spec. No. : As directed by Engineer in charge. SSR I.No.48.12, Sr.No.1631, P.No.311 (SSR 2022-23 GREEN BUILDING)(For Second Floor) |
| 226 | For Court Building-Providing and applying 2 Coats of 100% Pure acrylic water based paint with special heat reflectance property to withstand the harsh climate for period of atleast 10 years of approved make. Paint system should provide durable and long lasting finish with DFT of min 90 microns and should protect against concrete carbonation with R value of minimum 600 and equivalent concrete layer thickness value of min 150 cm. Paint should have breathability property and should be able to cover hairline cracks in the surface upto 0.5mm The paint has to be applied on a coat of high quality acrylic copolymer based alkali resistant primer with excellent penetrating properties including cleaning, with all leads and lifts at all levels etc complete, as directed by Engineer in charge..Spec. No. : As directed by Engineer in charge. SSR I.No.48.12, Sr.No.1631, P.No.311 (SSR 2022-23 GREEN BUILDING)(For Third Floor) |
| 227 | For Court Building-Providing and applying 2 Coats of 100% Pure acrylic water based paint with special heat reflectance property to withstand the harsh climate for period of atleast 10 years of approved make. Paint system should provide durable and long lasting finish with DFT of min 90 microns and should protect against concrete carbonation with R value of minimum 600 and equivalent concrete layer thickness value of min 150 cm. Paint should have breathability property and should be able to cover hairline cracks in the surface upto 0.5mm The paint has to be applied on a coat of high quality acrylic copolymer based alkali resistant primer with excellent penetrating properties including cleaning, with all leads and lifts at all levels etc complete, as directed by Engineer in charge..Spec. No. : As directed by Engineer in charge. SSR I.No.48.12, Sr.No.1631, P.No.311 (SSR 2022-23 GREEN BUILDING)(For Fourth Floor) |
| 228 | For Court Building-Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete Spec.No.As directed by Engineer in charge. SSR I.No.39.01, Sr.No.1194 P.No.245(For Parking Floor) |
| 229 | For Court Building-Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete Spec.No.As directed by Engineer in charge. SSR I.No.39.01, Sr.No.1194 P.No.245(For First Floor) |
| 230 | For Court Building-Providing and fixing Country cut teak wood double or single leaf panelled shutters, 35 mm thick style top and freze rail 95 x 35 thick with lock and bottam rail 195 x 25 mm thick and panels without ventilator as per detailed drawing excluding the door frame, stainless steel fixtures and fastening and finishing the wood work with oil painting 3 coats complete. Spec.No. BD-T-11 and 12 Page Number 482-83. SSR I.No.39.08, Sr.No.1201 P.No.246(For Parking Floor) |
| 231 | For Court Building-Providing and fixing Country cut teak wood double or single leaf panelled shutters, 35 mm thick style top and freze rail 95 x 35 thick with lock and bottam rail 195 x 25 mm thick and panels without ventilator as per detailed drawing excluding the door frame, stainless steel fixtures and fastening and finishing the wood work with oil painting 3 coats complete. Spec.No. BD-T-11 and 12 Page Number 482-83. SSR I.No.39.08, Sr.No.1201 P.No.246(For First Floor) |
| 232 | For Court Building-Providing and fixing 34 mm thick moulded door shutter consisting of solid core single leaf flush door of 30 mm thickness lipped with 15 mm ( 5mm x 3) thick x 30 mm width on one style and top rail and 10 mm (5mm x 2) thick x 30 mm width on other style and bottom rails. The inner panels laminated with 2 mm thick termite proof, water proof and fire resistant moulded PVC sheet with 2,4,6 design in different plain and /or prelim colours on one side after routing the moulded design on flush doors and 2 mm plain and /or pre lam PVC on other side using rubber adhesive on flush door and solvent cement adhesive on the PVC lipping etc. as per direction of Engineer in charge and manufacturersspecificationanddrawingetc. complete.. Spec. Nos. BD-T-34 Page Nos. 499. SSR I.Nos.39.48, Sr.Nos.1241 P.Nos.256(For Parking Floor) |
| 233 | For Court Building-Providing and fixing 34 mm thick moulded door shutter consisting of solid core single leaf flush door of 30 mm thickness lipped with 15 mm ( 5mm x 3) thick x 30 mm width on one style and top rail and 10 mm (5mm x 2) thick x 30 mm width on other style and bottom rails. The inner panels laminated with 2 mm thick termite proof, water proof and fire resistant moulded PVC sheet with 2,4,6 design in different plain and /or prelim colours on one side after routing the moulded design on flush doors and 2 mm plain and /or pre lam PVC on other side using rubber adhesive on flush door and solvent cement adhesive on the PVC lipping etc. as per direction of Engineer in charge and manufacturersspecificationanddrawingetc. complete.. Spec. Nos. BD-T-34 Page Nos. 499. SSR I.Nos.39.48, Sr.Nos.1241 P.Nos.256(For First Floor) |
| 234 | For Court Building-Providing and fixing 34 mm thick moulded door shutter consisting of solid core single leaf flush door of 30 mm thickness lipped with 15 mm ( 5mm x 3) thick x 30 mm width on one style and top rail and 10 mm (5mm x 2) thick x 30 mm width on other style and bottom rails. The inner panels laminated with 2 mm thick termite proof, water proof and fire resistant moulded PVC sheet with 2,4,6 design in different plain and /or prelim colours on one side after routing the moulded design on flush doors and 2 mm plain and /or pre lam PVC on other side using rubber adhesive on flush door and solvent cement adhesive on the PVC lipping etc. as per direction of Engineer in charge and manufacturersspecificationanddrawingetc. complete.. Spec. Nos. BD-T-34 Page Nos. 499. SSR I.Nos.39.48, Sr.Nos.1241 P.Nos.256(For Second Floor) |
| 235 | For Court Building-Providing and fixing 34 mm thick moulded door shutter consisting of solid core single leaf flush door of 30 mm thickness lipped with 15 mm ( 5mm x 3) thick x 30 mm width on one style and top rail and 10 mm (5mm x 2) thick x 30 mm width on other style and bottom rails. The inner panels laminated with 2 mm thick termite proof, water proof and fire resistant moulded PVC sheet with 2,4,6 design in different plain and /or prelim colours on one side after routing the moulded design on flush doors and 2 mm plain and /or pre lam PVC on other side using rubber adhesive on flush door and solvent cement adhesive on the PVC lipping etc. as per direction of Engineer in charge and manufacturersspecificationanddrawingetc. complete.. Spec. Nos. BD-T-34 Page Nos. 499. SSR I.Nos.39.48, Sr.Nos.1241 P.Nos.256(For Third Floor) |
| 236 | For Court Building-Providing and fixing 34 mm thick moulded door shutter consisting of solid core single leaf flush door of 30 mm thickness lipped with 15 mm ( 5mm x 3) thick x 30 mm width on one style and top rail and 10 mm (5mm x 2) thick x 30 mm width on other style and bottom rails. The inner panels laminated with 2 mm thick termite proof, water proof and fire resistant moulded PVC sheet with 2,4,6 design in different plain and /or prelim colours on one side after routing the moulded design on flush doors and 2 mm plain and /or pre lam PVC on other side using rubber adhesive on flush door and solvent cement adhesive on the PVC lipping etc. as per direction of Engineer in charge and manufacturersspecificationanddrawingetc. complete.. Spec. Nos. BD-T-34 Page Nos. 499. SSR I.Nos.39.48, Sr.Nos.1241 P.Nos.256(For Fourth Floor) |
| 237 | For Court Building-Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 mm x 1.22 mm box type, 5 mm thick sheet glasslouvers,of approved quality etc. complete..Spec. No. : As directed by Engineer in charge. SSR I.No.39.68, Sr.No.1263 P.No.259(For Parking Floor) |
| 238 | For Court Building-Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 mm x 1.22 mm box type, 5 mm thick sheet glasslouvers,of approved quality etc. complete..Spec. No. : As directed by Engineer in charge. SSR I.No.39.68, Sr.No.1263 P.No.259(For First Floor) |
| 239 | For Court Building-Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 mm x 1.22 mm box type, 5 mm thick sheet glasslouvers,of approved quality etc. complete..Spec. No. : As directed by Engineer in charge. SSR I.No.39.68, Sr.No.1263 P.No.259(For Second Floor) |
| 240 | For Court Building-Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 mm x 1.22 mm box type, 5 mm thick sheet glasslouvers,of approved quality etc. complete..Spec. No. : As directed by Engineer in charge. SSR I.No.39.68, Sr.No.1263 P.No.259(For Third Floor) |
| 241 | For Court Building-Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 mm x 1.22 mm box type, 5 mm thick sheet glasslouvers,of approved quality etc. complete..Spec. No. : As directed by Engineer in charge. SSR I.No.39.68, Sr.No.1263 P.No.259(For Fourth Floor) |
| 242 | For Court Building-Providing and Fixing 30 MM thick BOTH SIDE PRELAMINATED SOLID PANEL PVC DOOR SHUTTER consisting of frame made out of M.S tubes of 19 guage thickness and, size 19 x 19 mm for styles and 15 x15 mm for the top and bottom rails, M.S frame shall have a coat of metel primer of approved make and manufacture. M.S frame shall be covered with heat mouled PVC \"C\" channel made from 5 mm (+/0.25) thick prelaminated sheet of density 600 Kilogram/cbm ,of size 30mm thickness 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45? angle on either side forming stiles ; and 5 mm thick ,95 mm wide PVC sheet out of which 75 mm shall be falt and 20 mm shall be tapered in 45 on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be falt and 20 mm shall be tapered on both sides to form lock rail.Top,bottom and lock rail shall be provided either side of the panel. An additional 5 mm (+/0.25) thick PVC strip of 20 mm width is to be stuck on the bottom side of the \" c \" channel prelaminated paneling of 5 mm (+/0.25) thick PVC sheet to be fitted inside the M.S. frame welded/ sealed to the styles and rails with 5 mm (+/0.25) x 30 mm PVC sheet beading on either side and joined together with solvent cement adhesive etc ,10 mm thickness (5 mm (+/0.25) x 2 nos ) 20 mm wide cross PVC sheet as gap insert for the rail and bottom rail. Door to be fixed to frames with 3 nos M.S.powder coatedbuthingesofsize100mmx25MMx2mmusing32mmlongsteel screws drilled suitable to pass through both the walls of the M.S tube. Other hardwares Spec. No. : As directed by Engineer in charge. SSR I.No.39.47, Sr.No.1240 P.No.255(For Parking Floor) |
| 243 | For Court Building-Providing and Fixing 30 MM thick BOTH SIDE PRELAMINATED SOLID PANEL PVC DOOR SHUTTER consisting of frame made out of M.S tubes of 19 guage thickness and, size 19 x 19 mm for styles and 15 x15 mm for the top and bottom rails, M.S frame shall have a coat of metel primer of approved make and manufacture. M.S frame shall be covered with heat mouled PVC \"C\" channel made from 5 mm (+/0.25) thick prelaminated sheet of density 600 Kilogram/cbm ,of size 30mm thickness 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45? angle on either side forming stiles ; and 5 mm thick ,95 mm wide PVC sheet out of which 75 mm shall be falt and 20 mm shall be tapered in 45 on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be falt and 20 mm shall be tapered on both sides to form lock rail.Top,bottom and lock rail shall be provided either side of the panel. An additional 5 mm (+/0.25) thick PVC strip of 20 mm width is to be stuck on the bottom side of the \" c \" channel prelaminated paneling of 5 mm (+/0.25) thick PVC sheet to be fitted inside the M.S. frame welded/ sealed to the styles and rails with 5 mm (+/0.25) x 30 mm PVC sheet beading on either side and joined together with solvent cement adhesive etc ,10 mm thickness (5 mm (+/0.25) x 2 nos ) 20 mm wide cross PVC sheet as gap insert for the rail and bottom rail. Door to be fixed to frames with 3 nos M.S.powder coatedbuthingesofsize100mmx25MMx2mmusing32mmlongsteel screws drilled suitable to pass through both the walls of the M.S tube. Other hardwares Spec. No. : As directed by Engineer in charge. SSR I.No.39.47, Sr.No.1240 P.No.255(For First Floor) |
| 244 | For Court Building-Providing and Fixing 30 MM thick BOTH SIDE PRELAMINATED SOLID PANEL PVC DOOR SHUTTER consisting of frame made out of M.S tubes of 19 guage thickness and, size 19 x 19 mm for styles and 15 x15 mm for the top and bottom rails, M.S frame shall have a coat of metel primer of approved make and manufacture. M.S frame shall be covered with heat mouled PVC \"C\" channel made from 5 mm (+/0.25) thick prelaminated sheet of density 600 Kilogram/cbm ,of size 30mm thickness 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45? angle on either side forming stiles ; and 5 mm thick ,95 mm wide PVC sheet out of which 75 mm shall be falt and 20 mm shall be tapered in 45 on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be falt and 20 mm shall be tapered on both sides to form lock rail.Top,bottom and lock rail shall be provided either side of the panel. An additional 5 mm (+/0.25) thick PVC strip of 20 mm width is to be stuck on the bottom side of the \" c \" channel prelaminated paneling of 5 mm (+/0.25) thick PVC sheet to be fitted inside the M.S. frame welded/ sealed to the styles and rails with 5 mm (+/0.25) x 30 mm PVC sheet beading on either side and joined together with solvent cement adhesive etc ,10 mm thickness (5 mm (+/0.25) x 2 nos ) 20 mm wide cross PVC sheet as gap insert for the rail and bottom rail. Door to be fixed to frames with 3 nos M.S.powder coatedbuthingesofsize100mmx25MMx2mmusing32mmlongsteel screws drilled suitable to pass through both the walls of the M.S tube. Other hardwares Spec. No. : As directed by Engineer in charge. SSR I.No.39.47, Sr.No.1240 P.No.255(For Second Floor) |
| 245 | For Court Building-Providing and Fixing 30 MM thick BOTH SIDE PRELAMINATED SOLID PANEL PVC DOOR SHUTTER consisting of frame made out of M.S tubes of 19 guage thickness and, size 19 x 19 mm for styles and 15 x15 mm for the top and bottom rails, M.S frame shall have a coat of metel primer of approved make and manufacture. M.S frame shall be covered with heat mouled PVC \"C\" channel made from 5 mm (+/0.25) thick prelaminated sheet of density 600 Kilogram/cbm ,of size 30mm thickness 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45? angle on either side forming stiles ; and 5 mm thick ,95 mm wide PVC sheet out of which 75 mm shall be falt and 20 mm shall be tapered in 45 on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be falt and 20 mm shall be tapered on both sides to form lock rail.Top,bottom and lock rail shall be provided either side of the panel. An additional 5 mm (+/0.25) thick PVC strip of 20 mm width is to be stuck on the bottom side of the \" c \" channel prelaminated paneling of 5 mm (+/0.25) thick PVC sheet to be fitted inside the M.S. frame welded/ sealed to the styles and rails with 5 mm (+/0.25) x 30 mm PVC sheet beading on either side and joined together with solvent cement adhesive etc ,10 mm thickness (5 mm (+/0.25) x 2 nos ) 20 mm wide cross PVC sheet as gap insert for the rail and bottom rail. Door to be fixed to frames with 3 nos M.S.powder coatedbuthingesofsize100mmx25MMx2mmusing32mmlongsteel screws drilled suitable to pass through both the walls of the M.S tube. Other hardwares Spec. No. : As directed by Engineer in charge. SSR I.No.39.47, Sr.No.1240 P.No.255(For Third Floor) |
| 246 | For Court BuildingProviding and Fixing 30 MM thick BOTH SIDE PRELAMINATED SOLID PANEL PVC DOOR SHUTTER consisting of frame made out of M.S tubes of 19 guage thickness and, size 19 x 19 mm for styles and 15 x15 mm for the top and bottom rails, M.S frame shall have a coat of metel primer of approved make and manufacture. M.S frame shall be covered with heat mouled PVC \"C\" channel made from 5 mm (+/0.25) thick prelaminated sheet of density 600 Kilogram/cbm ,of size 30mm thickness 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45? angle on either side forming stiles ; and 5 mm thick ,95 mm wide PVC sheet out of which 75 mm shall be falt and 20 mm shall be tapered in 45 on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be falt and 20 mm shall be tapered on both sides to form lock rail.Top,bottom and lock rail shall be provided either side of the panel. An additional 5 mm (+/0.25) thick PVC strip of 20 mm width is to be stuck on the bottom side of the \" c \" channel prelaminated paneling of 5 mm (+/0.25) thick PVC sheet to be fitted inside the M.S. frame welded/ sealed to the styles and rails with 5 mm (+/0.25) x 30 mm PVC sheet beading on either side and joined together with solvent cement adhesive etc ,10 mm thickness (5 mm (+/0.25) x 2 nos ) 20 mm wide cross PVC sheet as gap insert for the rail and bottom rail. Door to be fixed to frames with 3 nos M.S.powder coatedbuthingesofsize100mmx25MMx2mmusing32mmlongsteel screws drilled suitable to pass through both the walls of the M.S tube. Other hardwares Spec. No. : As directed by Engineer in charge. SSR I.No.39.47, Sr.No.1240 P.No.255(For Fourth Floor) |
| 247 | For Court BuildingProviding and fixing in position U.P.V.C.(Unplasticized Poly Vinyl Chloride) having multi- chambered outer frame section (73 x 50)mm with an outer wall thickness of 2mm & steel reinforcement, multi-chambered slider frame (73x 60) mm with steel reinforcement, multi- chambered slider sash (46x 82) mm with steel reinforcement designed to give optimum strength, 5 mm thick toughened double glass with 12 mm spacer of good quality including alluminium track, Inter-locking profile, coextruded beadings, EPDM gaskets,silicon sealent,sliding handle, fixtures and fastenings (couplings, hinges) including with all required screws and nuts with all necessary U.P.V.C. sections as per the detailed drawing and as directed by Engineer-In-Charge etc. complete. Spec. No. : As directed by Engineer in charge.SSR I.No.48.22, Sr.No.1640 P.No.313(For Parking Floor) |
| 248 | For Court BuildingProviding and fixing in position U.P.V.C.(Unplasticized Poly Vinyl Chloride) having multi- chambered outer frame section (73 x 50)mm with an outer wall thickness of 2mm & steel reinforcement, multi-chambered slider frame (73x 60) mm with steel reinforcement, multi- chambered slider sash (46x 82) mm with steel reinforcement designed to give optimum strength, 5 mm thick toughened double glass with 12 mm spacer of good quality including alluminium track, Inter-locking profile, coextruded beadings, EPDM gaskets,silicon sealent,sliding handle, fixtures and fastenings (couplings, hinges) including with all required screws and nuts with all necessary U.P.V.C. sections as per the detailed drawing and as directed by Engineer-In-Charge etc. complete. Spec. No. : As directed by Engineer in charge.SSR I.No.48.22, Sr.No.1640 P.No.313(For First Floor) |
| 249 | For Court BuildingProviding and fixing in position U.P.V.C.(Unplasticized Poly Vinyl Chloride) having multi- chambered outer frame section (73 x 50)mm with an outer wall thickness of 2mm & steel reinforcement, multi-chambered slider frame (73x 60) mm with steel reinforcement, multi- chambered slider sash (46x 82) mm with steel reinforcement designed to give optimum strength, 5 mm thick toughened double glass with 12 mm spacer of good quality including alluminium track, Inter-locking profile, coextruded beadings, EPDM gaskets,silicon sealent,sliding handle, fixtures and fastenings (couplings, hinges) including with all required screws and nuts with all necessary U.P.V.C. sections as per the detailed drawing and as directed by Engineer-In-Charge etc. complete. Spec. No. : As directed by Engineer in charge.SSR I.No.48.22, Sr.No.1640 P.No.313(For Second Floor) |
| 250 | For Court BuildingProviding and fixing in position U.P.V.C.(Unplasticized Poly Vinyl Chloride) having multi- chambered outer frame section (73 x 50)mm with an outer wall thickness of 2mm & steel reinforcement, multi-chambered slider frame (73x 60) mm with steel reinforcement, multi- chambered slider sash (46x 82) mm with steel reinforcement designed to give optimum strength, 5 mm thick toughened double glass with 12 mm spacer of good quality including alluminium track, Inter-locking profile, coextruded beadings, EPDM gaskets,silicon sealent,sliding handle, fixtures and fastenings (couplings, hinges) including with all required screws and nuts with all necessary U.P.V.C. sections as per the detailed drawing and as directed by Engineer-In-Charge etc. complete. Spec. No. : As directed by Engineer in charge.SSR I.No.48.22, Sr.No.1640 P.No.313(For Third Floor) |
| 251 | For Court BuildingProviding and fixing in position U.P.V.C.(Unplasticized Poly Vinyl Chloride) having multi- chambered outer frame section (73 x 50)mm with an outer wall thickness of 2mm & steel reinforcement, multi-chambered slider frame (73x 60) mm with steel reinforcement, multi- chambered slider sash (46x 82) mm with steel reinforcement designed to give optimum strength, 5 mm thick toughened double glass with 12 mm spacer of good quality including alluminium track, Inter-locking profile, coextruded beadings, EPDM gaskets,silicon sealent,sliding handle, fixtures and fastenings (couplings, hinges) including with all required screws and nuts with all necessary U.P.V.C. sections as per the detailed drawing and as directed by Engineer-In-Charge etc. complete. Spec. No. : As directed by Engineer in charge.SSR I.No.48.22, Sr.No.1640 P.No.313(For Fourth Floor) |
| 252 | For Court BuildingSliding Window- 3 Track (2 Glass shutter + 1 flymesh) of approved make with DGU, providing and fixing of Sliding Window- 3 Track (2 Glass shutter + 1 flymesh ). For details refer to Specifications. As directed by Engineer in charge. Spec. No. : As directed by Engineer in charge.SSR I.No.48.23, Sr.No.1641 P.No.314(For First Floor) |
| 253 | For Court BuildingSliding Window- 3 Track (2 Glass shutter + 1 flymesh) of approved make with DGU, providing and fixing of Sliding Window- 3 Track (2 Glass shutter + 1 flymesh ). For details refer to Specifications. As directed by Engineer in charge. Spec. No. : As directed by Engineer in charge.SSR I.No.48.23, Sr.No.1641 P.No.314(For Second Floor) |
| 254 | For Court BuildingSliding Window- 3 Track (2 Glass shutter + 1 flymesh) of approved make with DGU, providing and fixing of Sliding Window- 3 Track (2 Glass shutter + 1 flymesh ). For details refer to Specifications. As directed by Engineer in charge. Spec. No. : As directed by Engineer in charge.SSR I.No.48.23, Sr.No.1641 P.No.314(For Third Floor) |
| 255 | For Court BuildingSliding Window- 3 Track (2 Glass shutter + 1 flymesh) of approved make with DGU, providing and fixing of Sliding Window- 3 Track (2 Glass shutter + 1 flymesh ). For details refer to Specifications. As directed by Engineer in charge. Spec. No. : As directed by Engineer in charge.SSR I.No.48.23, Sr.No.1641 P.No.314(For Fourth Floor) |
| 256 | For Court BuildingProviding and fixing M40 grade thick vibrated pull cast or similar type concrete frame with chamfer conforming to I.S. 65241983 having 6 mm dia. bars 3 Nos. And stirrups @250 mm c/c and fixing in wall with 6 Nos of hold fast of 12 mm dia bars 500 mm longincluding primer and oil painting etc, complete) frame size 60 mm x 100 mm . .Spec. No. As directed by Engineer in harge. SSR I.No.39.56, Sr.No.1252 P.No.257 ( For Terrace Floor) |
| 257 | For Court BuildingProviding and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram/ One Square Metre as per drawing including fixtures, necessary welding and painting with one coatsof anticorrosive paint and two coats of oil painting complete..Spec. No. : Bd.U. 1 Page No. 537. SSR I.No.40.01, Sr.No.1291 P.No.264(For Parking Floor) |
| 258 | For Court BuildingProviding and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram/ One Square Metre as per drawing including fixtures, necessary welding and painting with one coatsof anticorrosive paint and two coats of oil painting complete..Spec. No. : Bd.U. 1 Page No. 537. SSR I.No.40.01, Sr.No.1291 P.No.264(For First Floor) |
| 259 | For Court BuildingProviding and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram/ One Square Metre as per drawing including fixtures, necessary welding and painting with one coatsof anticorrosive paint and two coats of oil painting complete..Spec. No. : Bd.U. 1 Page No. 537. SSR I.No.40.01, Sr.No.1291 P.No.264(For Second Floor) |
| 260 | For Court BuildingProviding and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram/ One Square Metre as per drawing including fixtures, necessary welding and painting with one coatsof anticorrosive paint and two coats of oil painting complete..Spec. No. : Bd.U. 1 Page No. 537. SSR I.No.40.01, Sr.No.1291 P.No.264(For Third Floor) |
| 261 | For Court BuildingProviding and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram/ One Square Metre as per drawing including fixtures, necessary welding and painting with one coatsof anticorrosive paint and two coats of oil painting complete..Spec. No. : Bd.U. 1 Page No. 537. SSR I.No.40.01, Sr.No.1291 P.No.264(For Fourth Floor) |
| 262 | For Court BuildingProviding and Fixing mat finish stainless steel (of 302 grade ) railing with top pipe of 50 mm dia. and vertical pipe of 38 mm dia at 0.60 m c/c or as required and horizontal pipes of 25 mm dia in three rows, all pipes of 2 mm thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 mm dia above newel post of 75 mm diameter etc. complete (Prior approval of sample and brand by Ex.Engineeris necessary before use) Spec No.:As directed by Engineer Incharge.SSR I.No.40.08, Sr.No.1298 P.No.265(For Parking Floor) |
| 263 | For Court BuildingProviding and Fixing mat finish stainless steel (of 302 grade ) railing with top pipe of 50 mm dia. and vertical pipe of 38 mm dia at 0.60 m c/c or as required and horizontal pipes of 25 mm dia in three rows, all pipes of 2 mm thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 mm dia above newel post of 75 mm diameter etc. complete (Prior approval of sample and brand by Ex.Engineeris necessary before use) Spec No.:As directed by Engineer Incharge.SSR I.No.40.08, Sr.No.1298 P.No.265(For First Floor) |
| 264 | For Court BuildingProviding and Fixing mat finish stainless steel (of 302 grade ) railing with top pipe of 50 mm dia. and vertical pipe of 38 mm dia at 0.60 m c/c or as required and horizontal pipes of 25 mm dia in three rows, all pipes of 2 mm thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 mm dia above newel post of 75 mm diameter etc. complete (Prior approval of sample and brand by Ex.Engineeris necessary before use) Spec No.:As directed by Engineer Incharge.SSR I.No.40.08, Sr.No.1298 P.No.265(For Second Floor) |
| 265 | For Court BuildingProviding and Fixing mat finish stainless steel (of 302 grade ) railing with top pipe of 50 mm dia. and vertical pipe of 38 mm dia at 0.60 m c/c or as required and horizontal pipes of 25 mm dia in three rows, all pipes of 2 mm thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 mm dia above newel post of 75 mm diameter etc. complete (Prior approval of sample and brand by Ex.Engineeris necessary before use) Spec No.:As directed by Engineer Incharge.SSR I.No.40.08, Sr.No.1298 P.No.265(For Third Floor) |
| 266 | For Court BuildingProviding and Fixing mat finish stainless steel (of 302 grade ) railing with top pipe of 50 mm dia. and vertical pipe of 38 mm dia at 0.60 m c/c or as required and horizontal pipes of 25 mm dia in three rows, all pipes of 2 mm thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 mm dia above newel post of 75 mm diameter etc. complete (Prior approval of sample and brand by Ex.Engineeris necessary before use) Spec No.:As directed by Engineer Incharge.SSR I.No.40.08, Sr.No.1298 P.No.265(For Fourth Floor) |
| 267 | For Court BuildingProviding and fixing C.P. 2 Way BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge. SSR I.No.48.27, Sr.No.1644, P.No.314 (SSR 2022-23 GREEN BUILDING) (Jaquar / Equivalent make Confirming Green Bldg Certificate)(For Parking Floor) |
| 268 | For Court BuildingProviding and fixing C.P. 2 Way BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge. SSR I.No.48.27, Sr.No.1644, P.No.314 (SSR 2022-23 GREEN BUILDING) (Jaquar / Equivalent make Confirming Green Bldg Certificate)(For First Floor) |
| 269 | For Court BuildingProviding and fixing C.P. 2 Way BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge. SSR I.No.48.27, Sr.No.1644, P.No.314 (SSR 2022-23 GREEN BUILDING) (Jaquar / Equivalent make Confirming Green Bldg Certificate)(For Second Floor) |
| 270 | For Court BuildingProviding and fixing C.P. 2 Way BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge. SSR I.No.48.27, Sr.No.1644, P.No.314 (SSR 2022-23 GREEN BUILDING) (Jaquar / Equivalent make Confirming Green Bldg Certificate)(For Third Floor) |
| 271 | For Court BuildingProviding and fixing C.P. 2 Way BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge. SSR I.No.48.27, Sr.No.1644, P.No.314 (SSR 2022-23 GREEN BUILDING) (Jaquar / Equivalent make Confirming Green Bldg Certificate)(For Fourth Floor) |
| 272 | For Court BuildingProviding and fixing 25mm diameter water meter with non-return valve including strainer, sockets/ union nut and including water meter box making locking arrangementandlock. [Without chamber]... Spec. No. :Bd.V.7 Page No. 554.SSR I.No.41.28, Sr.No.1329, P.no.269(For Parking Floor) |
| 273 | For Court BuildingProviding and fixing 15 mm dia. screw down bib/ stop tap of brass including necessary socket union nut complete. Spec. No.: Bd.V. 8 Page No. 554..SSR I.No.41.40, Sr.No.1334, P.No.270(For Parking Floor) |
| 274 | For Court BuildingProviding and fixing 15 mm dia. screw down bib/ stop tap of brass including necessary socket union nut complete. Spec. No.: Bd.V. 8 Page No. 554..SSR I.No.41.40, Sr.No.1334, P.No.270(For First Floor) |
| 275 | For Court BuildingProviding and fixing 15 mm dia. screw down bib/ stop tap of brass including necessary socket union nut complete. Spec. No.: Bd.V. 8 Page No. 554..SSR I.No.41.40, Sr.No.1334, P.No.270(For Second Floor) |
| 276 | For Court BuildingProviding and fixing 15 mm dia. screw down bib/ stop tap of brass including necessary socket union nut complete. Spec. No.: Bd.V. 8 Page No. 554..SSR I.No.41.40, Sr.No.1334, P.No.270(For Third Floor) |
| 277 | For Court BuildingProviding and fixing 15 mm dia. screw down bib/ stop tap of brass including necessary socket union nut complete. Spec. No.: Bd.V. 8 Page No. 554..SSR I.No.41.40, Sr.No.1334, P.No.270(For Fourth Floor) |
| 278 | For Court BuildingProviding and fixing 20 mm dia. screw down bib/ stop tap of brass including necessary socket union nut complete. . Bd.V.8 Page No.554..SSR I.No.41.41, Sr.No.1335, P.No.270(For Parking Floor) |
| 279 | For Court BuildingProviding and fixing 20 mm dia. screw down bib/ stop tap of brass including necessary socket union nut complete. . Bd.V.8 Page No.554..SSR I.No.41.41, Sr.No.1335, P.No.270(For First Floor) |
| 280 | For Court BuildingProviding and fixing 20 mm dia. screw down bib/ stop tap of brass including necessary socket union nut complete. . Bd.V.8 Page No.554..SSR I.No.41.41, Sr.No.1335, P.No.270(For Second Floor) |
| 281 | For Court BuildingProviding and fixing 20 mm dia. screw down bib/ stop tap of brass including necessary socket union nut complete. . Bd.V.8 Page No.554..SSR I.No.41.41, Sr.No.1335, P.No.270(For Third Floor) |
| 282 | For Court BuildingProviding and fixing 20 mm dia. screw down bib/ stop tap of brass including necessary socket union nut complete. . Bd.V.8 Page No.554..SSR I.No.41.41, Sr.No.1335, P.No.270(For Fourth Floor) |
| 283 | For Court BuildingProviding and fixing screw down 15 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete Bd.V.9 Page No.555.SSR I.No.41.43, Sr.No.1337 P.No.270(For Parking Floor) |
| 284 | For Court BuildingProviding and fixing screw down 15 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete Bd.V.9 Page No.555.SSR I.No.41.43, Sr.No.1337 P.No.270(For First Floor) |
| 285 | For Court BuildingProviding and fixing screw down 15 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete Bd.V.9 Page No.555.SSR I.No.41.43, Sr.No.1337 P.No.270(For Second Floor) |
| 286 | For Court BuildingProviding and fixing screw down 15 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete Bd.V.9 Page No.555.SSR I.No.41.43, Sr.No.1337 P.No.270(For Third Floor) |
| 287 | For Court BuildingProviding and fixing screw down 15 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete Bd.V.9 Page No.555.SSR I.No.41.43, Sr.No.1337 P.No.270(For Fourth Floor) |
| 288 | For Court BuildingProviding and fixing push cock (Self closing tap) symet type of 15 mm dia. including necessary socket, testing etc. complete. Spec No.:As directed by Engineer in charge. SSR I.No.41.54, Sr.No.1348, P.No.271 (Jaquar / Equivalent make Confirming Green Bldg Certificate)(For Parking Floor) |
| 289 | For Court BuildingProviding and fixing push cock (Self closing tap) symet type of 15 mm dia. including necessary socket, testing etc. complete. Spec No.:As directed by Engineer in charge. SSR I.No.41.54, Sr.No.1348, P.No.271 (Jaquar / Equivalent make Confirming Green Bldg Certificate)(For First Floor) |
| 290 | For Court BuildingProviding and fixing push cock (Self closing tap) symet type of 15 mm dia. including necessary socket, testing etc. complete. Spec No.:As directed by Engineer in charge. SSR I.No.41.54, Sr.No.1348, P.No.271 (Jaquar / Equivalent make Confirming Green Bldg Certificate)(For Second Floor) |
| 291 | For Court BuildingProviding and fixing push cock (Self closing tap) symet type of 15 mm dia. including necessary socket, testing etc. complete. Spec No.:As directed by Engineer in charge. SSR I.No.41.54, Sr.No.1348, P.No.271 (Jaquar / Equivalent make Confirming Green Bldg Certificate)(For Third Floor) |
| 292 | For Court BuildingProviding and fixing push cock (Self closing tap) symet type of 15 mm dia. including necessary socket, testing etc. complete. Spec No.:As directed by Engineer in charge. SSR I.No.41.54, Sr.No.1348, P.No.271 (Jaquar / Equivalent make Confirming Green Bldg Certificate)(For Fourth Floor) |
| 293 | For Court BuildingProviding and fixing White glazed with bottle trap earthenware Wash Hand Basin of 63x45 cm size including cold water piller taps, brackets, rubber plugs and brass chain, stop tap, chromium plate bottle trap and necessary pipe connections including UPAC waste pipe and trap upto the outside face of the wall, making good the damagedsurface,testingetc. complete. BDV.-30Page Number616. SSR I.No.41.70, Sr.No.1363 P.No.272 (Jaquar / Equivalent make Confirming Green Bldg Certificate)(For Parking Floor) |
| 294 | For Court BuildingProviding and fixing White glazed with bottle trap earthenware Wash Hand Basin of 63x45 cm size including cold water piller taps, brackets, rubber plugs and brass chain, stop tap, chromium plate bottle trap and necessary pipe connections including UPAC waste pipe and trap upto the outside face of the wall, making good the damagedsurface,testingetc. complete. BDV.-30Page Number616. SSR I.No.41.70, Sr.No.1363 P.No.272 (Jaquar / Equivalent make Confirming Green Bldg Certificate)(For First Floor) |
| 295 | For Court BuildingProviding and fixing White glazed with bottle trap earthenware Wash Hand Basin of 63x45 cm size including cold water piller taps, brackets, rubber plugs and brass chain, stop tap, chromium plate bottle trap and necessary pipe connections including UPAC waste pipe and trap upto the outside face of the wall, making good the damagedsurface,testingetc. complete. BDV.-30Page Number616. SSR I.No.41.70, Sr.No.1363 P.No.272 (Jaquar / Equivalent make Confirming Green Bldg Certificate)(For Second Floor) |
| 296 | For Court BuildingProviding and fixing White glazed with bottle trap earthenware Wash Hand Basin of 63x45 cm size including cold water piller taps, brackets, rubber plugs and brass chain, stop tap, chromium plate bottle trap and necessary pipe connections including UPAC waste pipe and trap upto the outside face of the wall, making good the damagedsurface,testingetc. complete. BDV.-30Page Number616. SSR I.No.41.70, Sr.No.1363 P.No.272 (Jaquar / Equivalent make Confirming Green Bldg Certificate)(For Third Floor) |
| 297 | For Court BuildingProviding and fixing White glazed with bottle trap earthenware Wash Hand Basin of 63x45 cm size including cold water piller taps, brackets, rubber plugs and brass chain, stop tap, chromium plate bottle trap and necessary pipe connections including UPAC waste pipe and trap upto the outside face of the wall, making good the damagedsurface,testingetc. complete. BDV.-30Page Number616. SSR I.No.41.70, Sr.No.1363 P.No.272 (Jaquar / Equivalent make Confirming Green Bldg Certificate)(For Fourth Floor) |
| 298 | For Court BuildingProviding and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap. Spec. No. : Bd.V. 38 Page No. 531. SSR I.No.42.02, Sr.No.1373 P.No.274(For Parking Floor) |
| 299 | For Court BuildingProviding and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap. Spec. No. : Bd.V. 38 Page No. 531. SSR I.No.42.02, Sr.No.1373 P.No.274(For First Floor) |
| 300 | For Court BuildingProviding and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap. Spec. No. : Bd.V. 38 Page No. 531. SSR I.No.42.02, Sr.No.1373 P.No.274(For Second Floor) |
| 301 | For Court BuildingProviding and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap. Spec. No. : Bd.V. 38 Page No. 531. SSR I.No.42.02, Sr.No.1373 P.No.274(For Third Floor) |
| 302 | For Court BuildingProviding and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap. Spec. No. : Bd.V. 38 Page No. 531. SSR I.No.42.02, Sr.No.1373 P.No.274(For Fourth Floor) |
| 303 | For Court BuildingProviding and laying concrete pipes of I.S.NP. class of 150mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.Spec. No. :Bd.V.41, Page No. 573.SSR I.No.42.07, Sr.No.1378 P.No.274(For Parking Floor) |
| 304 | For Court BuildingProviding and laying concrete pipes of I.S.NP. class of 300mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.. Spec. No. :Bd.V.41, Page No. 573.SSR I.No.42.09, Sr.No.1380 P.No.274(For Parking Floor) |
| 305 | For Court BuildingProviding , constructing and fixing 250 mm dia. Inspection chamber made up of UPVC material of thickness 3.5 mm and height of 259 mm with inlet and outlet of 110 mm dia. with 75 mm dia. U Trap, Ultra shaft pipe of Upvc material having height of 470 mm and fixing Ultra 250 mm dia. UPVC cover and frame in 150 mm thick in c.c.1:2:4, having crushed sand bed of 100 mm thick of size 550 mm dia. Including excavation and refilling the sides of chamber by crushed sand cushioning 150 mm thickness,connectingallrequiredUPVC fittings with rubber lubricant etc. complete.. Spec. Nos. : As Directected By Engineer Incharge. SSR I.Nos.43.27, Sr.Nos.1498, P.Nos.290(For Parking Floor) |
| 306 | For Court BuildingProviding , constructing and fixing 450 mm dia. Inspection chamber made up of Polypropylene / polyethylene material of thickness 3.5 mm and height of 388 mm with 160 or 200 mm main inlet (s) outlet and 110 and / or 160 mm branch inlets, with 450 mm dia. Ultra shaft pipe of HDPE material having height of 460 mm, having R.C.C. cover and frame fixing in 150 mm thick in c.c.1:2:4, having crushed sand bed of 150 mm thick of size 750 mm dia. Including excavation and refilling the sides of chamber by sand crushed cushioning 150 mm thickness, connecting all required UPVC fittings with rubber lubricant etc. complete. Spec. Nos. : As Directected By Engineer Incharge. SSR I.Nos.43.28, Sr.Nos.1499, P.Nos.290(For Parking Floor) |
| 307 | For Court BuildingProviding and fixing 450mm x 550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete..Spec No.:As directed by Engineer in charge.. SSR I.No.42.20, Sr.No.1391, P.No.276(For Parking Floor) |
| 308 | For Court BuildingProviding and fixing 450mm x 550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete..Spec No.:As directed by Engineer in charge.. SSR I.No.42.20, Sr.No.1391, P.No.276(ForFirstFloor) |
| 309 | For Court BuildingProviding and fixing 450mm x 550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete..Spec No.:As directed by Engineer in charge.. SSR I.No.42.20, Sr.No.1391, P.No.276(For Second Floor) |
| 310 | For Court BuildingProviding and fixing 450mm x 550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete..Spec No.:As directed by Engineer in charge.. SSR I.No.42.20, Sr.No.1391, P.No.276(For Third Floor) |
| 311 | For Court BuildingProviding and fixing 450mm x 550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete..Spec No.:As directed by Engineer in charge.. SSR I.No.42.20, Sr.No.1391, P.No.276(For Fourth Floor) |
| 312 | For Court BuildingProviding and fixing chromium plated towel rod 16 mm dia and 75 cm. in length including all accessories complete. Spec. No. : As directed by Engineer in charge. SSRI.No.42.31, Sr.No.1402, P.No.277(For Parking Floor) |
| 313 | For Court BuildingProviding and fixing chromium plated towel rod 16 mm dia and 75 cm. in length including all accessories complete. Spec. No. : As directed by Engineer in charge. SSRI.No.42.31, Sr.No.1402, P.No.277(For First Floor) |
| 314 | For Court BuildingProviding and fixing chromium plated towel rod 16 mm dia and 75 cm. in length including all accessories complete. Spec. No. : As directed by Engineer in charge. SSRI.No.42.31, Sr.No.1402, P.No.277(For Second Floor) |
| 315 | For Court BuildingProviding and fixing chromium plated towel rod 16 mm dia and 75 cm. in length including all accessories complete. Spec. No. : As directed by Engineer in charge. SSRI.No.42.31, Sr.No.1402, P.No.277(For Third Floor) |
| 316 | For Court BuildingProviding and fixing chromium plated towel rod 16 mm dia and 75 cm. in length including all accessories complete. Spec. No. : As directed by Engineer in charge. SSRI.No.42.31, Sr.No.1402, P.No.277(For Fourth Floor) |
| 317 | For Court BuildingProviding and fixing stainless steel sink of size 600 x 510 x 200 mm incluidng coupling, outlet pipe, elbow and other necessary fitting, finishing etc. complete... Spec No.:As directed by Engineer in charge. SSR I.No.42.78, Sr.No.1449, P.No.282(Jaquar / Equivalent make Confirming Green Bldg Certificate)(For First Floor) |
| 318 | For Court BuildingProviding and fixing C.P. Angular stop clock with wall flange of approved make continental including necessary sockets/union nut etc. complete. Spec No.:As directed by Engineer in charge. SSR I.No.42.79, Sr.No.1450, P.No.282 (Jaquar / Equivalent make Confirming Green Bldg Certificate)(For Parking Floor) |
| 319 | For Court BuildingProviding and fixing C.P. Angular stop clock with wall flange of approved make continental including necessary sockets/union nut etc. complete. Spec No.:As directed by Engineer in charge. SSR I.No.42.79, Sr.No.1450, P.No.282 (Jaquar / Equivalent make Confirming Green Bldg Certificate)(For First Floor) |
| 320 | For Court BuildingProviding and fixing C.P. Angular stop clock with wall flange of approved make continental including necessary sockets/union nut etc. complete. Spec No.:As directed by Engineer in charge. SSR I.No.42.79, Sr.No.1450, P.No.282 (Jaquar / Equivalent make Confirming Green Bldg Certificate)(For Second Floor) |
| 321 | For Court BuildingProviding and fixing C.P. Angular stop clock with wall flange of approved make continental including necessary sockets/union nut etc. complete. Spec No.:As directed by Engineer in charge. SSR I.No.42.79, Sr.No.1450, P.No.282 (Jaquar / Equivalent make Confirming Green Bldg Certificate)(For Third Floor) |
| 322 | For Court BuildingProviding and fixing C.P. Angular stop clock with wall flange of approved make continental including necessary sockets/union nut etc. complete. Spec No.:As directed by Engineer in charge. SSR I.No.42.79, Sr.No.1450, P.No.282 (Jaquar / Equivalent make Confirming Green Bldg Certificate)(For Fourth Floor) |
| 323 | For Court BuildingProviding and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete. Spec No.:As directed by Engineer in charge. SSR I.No.42.83, Sr.No.1454, P.No.283 (Jaquar / Equivalent make Confirming Green Bldg Certificate)(For Parking Floor) |
| 324 | For Court BuildingProviding and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete. Spec No.:As directed by Engineer in charge. SSR I.No.42.83, Sr.No.1454, P.No.283 (Jaquar / Equivalent make Confirming Green Bldg Certificate)(For First Floor) |
| 325 | For Court BuildingProviding and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete. Spec No.:As directed by Engineer in charge. SSR I.No.42.83, Sr.No.1454, P.No.283 (Jaquar / Equivalent make Confirming Green Bldg Certificate)(For Second Floor) |
| 326 | For Court BuildingProviding and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete. Spec No.:As directed by Engineer in charge. SSR I.No.42.83, Sr.No.1454, P.No.283 (Jaquar / Equivalent make Confirming Green Bldg Certificate)(For Third Floor) |
| 327 | For Court BuildingProviding and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete. Spec No.:As directed by Engineer in charge. SSR I.No.42.83, Sr.No.1454, P.No.283 (Jaquar / Equivalent make Confirming Green Bldg Certificate)(For Fourth Floor) |
| 328 | For Court BuildingProviding and fixing C.P. sink cock with raised J\" shaped swinging casted spout ofapproved make including necessary sockets/ union nut etc. complete.\" Spec No.:As directed by Engineer in charge. SSR I.No.42.84, Sr.No.1455, P.No.283 (Jaquar / Equivalent make Confirming Green Bldg Certificate)(For First Floor) |
| 329 | For Court BuildingProviding and fixing 40 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirements etc. complete. . Spec No.:As directed by Engineer in charge. SSR I.No.42.36, Sr.No.1407, P.No.277 (For Terrace Floor) |
| 330 | For Court BuildingProviding and fixing 15 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirement etc. complete.Spec No.:As directed by Engineer in charge. SSR I.No.42.37, Sr.No.1408, P.No.277 (For Terrace Floor) |
| 331 | For Court BuildingProviding and fixing Shower Head, with shower arm of approved make mixer of including all necessary pipe fittings and connections etc. complete as directed by Engineer in charge.Spec Nos.:As directed by Engineer in charge. SSR I.Nos.48.34, Sr.Nos.1650, P.Nos.315(Jaquar / Equivalent make Confirming Green Bldg Certificate)(For Parking Floor) |
| 332 | For Court BuildingProviding and fixing Shower Head, with shower arm of approved make mixer of including all necessary pipe fittings and connections etc. complete as directed by Engineer in charge.Spec Nos.:As directed by Engineer in charge. SSR I.Nos.48.34, Sr.Nos.1650, P.Nos.315(Jaquar / Equivalent make Confirming Green Bldg Certificate)(For First Floor) |
| 333 | For Court BuildingProviding and fixing Shower Head, with shower arm of approved make mixer of including all necessary pipe fittings and connections etc. complete as directed by Engineer in charge.Spec Nos.:As directed by Engineer in charge. SSR I.Nos.48.34, Sr.Nos.1650, P.Nos.315(Jaquar / Equivalent make Confirming Green Bldg Certificate)(For Second Floor) |
| 334 | For Court BuildingProviding and fixing Shower Head, with shower arm of approved make mixer of including all necessary pipe fittings and connections etc. complete as directed by Engineer in charge.Spec Nos.:As directed by Engineer in charge. SSR I.Nos.48.34, Sr.Nos.1650, P.Nos.315(Jaquar / Equivalent make Confirming Green Bldg Certificate)(For Third Floor) |
| 335 | For Court BuildingProviding and fixing Shower Head, with shower arm of approved make mixer of including all necessary pipe fittings and connections etc. complete as directed by Engineer in charge.Spec Nos.:As directed by Engineer in charge. SSR I.Nos.48.34, Sr.Nos.1650, P.Nos.315(Jaquar / Equivalent make Confirming Green Bldg Certificate)(For Fourth Floor) |
| 336 | For Court BuildingProviding and fixing C.P. wall mixer with provision for overhead shower with 115mm long bend pipe and wall flange of approved make including necessary sockets/unionnutetc. complete. Spec Nos.:As directed by Engineer in charge. SSR I.Nos.42.81, Sr.Nos.1452, P.Nos.282 (Jaquar / Equivalent make Confirming Green Bldg Certificate)(For Parking Floor) |
| 337 | For Court BuildingProviding and fixing C.P. wall mixer with provision for overhead shower with 115mm long bend pipe and wall flange of approved make including necessary sockets/unionnutetc. complete. Spec Nos.:As directed by Engineer in charge. SSR I.Nos.42.81, Sr.Nos.1452, P.Nos.282 (Jaquar / Equivalent make Confirming Green Bldg Certificate)(For First Floor) |
| 338 | For Court BuildingProviding and fixing C.P. wall mixer with provision for overhead shower with 115mm long bend pipe and wall flange of approved make including necessary sockets/unionnutetc. complete. Spec Nos.:As directed by Engineer in charge. SSR I.Nos.42.81, Sr.Nos.1452, P.Nos.282 (Jaquar / Equivalent make Confirming Green Bldg Certificate)(For Second Floor) |
| 339 | For Court BuildingProviding and fixing C.P. wall mixer with provision for overhead shower with 115mm long bend pipe and wall flange of approved make including necessary sockets/unionnutetc. complete. Spec Nos.:As directed by Engineer in charge. SSR I.Nos.42.81, Sr.Nos.1452, P.Nos.282 (Jaquar / Equivalent make Confirming Green Bldg Certificate)(For Third Floor) |
| 340 | For Court BuildingProviding and fixing C.P. wall mixer with provision for overhead shower with 115mm long bend pipe and wall flange of approved make including necessary sockets/unionnutetc. complete. Spec Nos.:As directed by Engineer in charge. SSR I.Nos.42.81, Sr.Nos.1452, P.Nos.282 (Jaquar / Equivalent make Confirming Green Bldg Certificate(For Fourth Floor) |
| 341 | For Court BuildingProviding and fixing Orissa Pan of size 580x445x260 mm with approved make flush valve including trap, C.I. soil and vent pipe upto outside face of wall including 100mm dia. C.I. plug, bend and necessary pipe connection, etc complete. As directed by Engineer in charge.. Spec No. As directed by Engineer in charge. SSR I.No.48.38, Sr.No.1654, P.No.315 (SSR 2022-23 GREEN BUILDING) (Jaquar / Equivalent make Confirming Green Bldg Certificate)(For Parking Floor) |
| 342 | For Court BuildingProviding and fixing white Opal series European type wall-hung, of size 400 mm x 370 mm x 575mm with approved make flush valve including soil pipe, vent pipe upto outside face of wall, 100mm dia C.I. plug bend inlet pipe all fittings, cutting & making good walls, floors etc as directed by Engineer in charge.. Spec No.:As directed by Engineer in charge. SSR I.No.48.37, Sr.No.1653, P.No.315 (SSR 2022-23 GREEN BUILDING) (Jaquar / Equivalent make Confirming Green Bldg Certificate)(For Parking Floor) |
| 343 | For Court BuildingProviding and fixing white Opal series European type wall-hung, of size 400 mm x 370 mm x 575mm with approved make flush valve including soil pipe, vent pipe upto outside face of wall, 100mm dia C.I. plug bend inlet pipe all fittings, cutting & making good walls, floors etc as directed by Engineer in charge.. Spec No.:As directed by Engineer in charge. SSR I.No.48.37, Sr.No.1653, P.No.315 (SSR 2022-23 GREEN BUILDING) (Jaquar / Equivalent make Confirming Green Bldg Certificate)(For First Floor) |
| 344 | For Court BuildingProviding and fixing white Opal series European type wall-hung, of size 400 mm x 370 mm x 575mm with approved make flush valve including soil pipe, vent pipe upto outside face of wall, 100mm dia C.I. plug bend inlet pipe all fittings, cutting & making good walls, floors etc as directed by Engineer in charge.. Spec No.:As directed by Engineer in charge. SSR I.No.48.37, Sr.No.1653, P.No.315 (SSR 2022-23 GREEN BUILDING) (Jaquar / Equivalent make Confirming Green Bldg Certificate)(For Second Floor) |
| 345 | For Court BuildingProviding and fixing white Opal series European type wall-hung, of size 400 mm x 370 mm x 575mm with approved make flush valve including soil pipe, vent pipe upto outside face of wall, 100mm dia C.I. plug bend inlet pipe all fittings, cutting & making good walls, floors etc as directed by Engineer in charge.. Spec No.:As directed by Engineer in charge. SSR I.No.48.37, Sr.No.1653, P.No.315 (SSR 2022-23 GREEN BUILDING) (Jaquar / Equivalent make Confirming Green Bldg Certificate)(For Third Floor) |
| 346 | For Court BuildingProviding and fixing white Opal series European type wall-hung, of size 400 mm x 370 mm x 575mm with approved make flush valve including soil pipe, vent pipe upto outside face of wall, 100mm dia C.I. plug bend inlet pipe all fittings, cutting & making good walls, floors etc as directed by Engineer in charge.. Spec No.:As directed by Engineer in charge. SSR I.No.48.37, Sr.No.1653, P.No.315 (SSR 2022-23 GREEN BUILDING) (Jaquar / Equivalent make Confirming Green Bldg Certificate)(For Fourth Floor) |
| 347 | For Court BuildingProviding and fixing White Glazed Earthenware full stall type Urinal with P.V.C. flushing cistern of 5 liters capacity with fitting, inlet pipes and stop tap, brackets for fixing the cistern, 32 mm dia. P.V.C flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap, soil pipe connectionup to the outside face of the wall. Spec No.:As directed by Engineer in charge. SSR I.No.41.57, Sr.No.1351, P.No.271 (Jaquar / Equivalent make Confirming Green Bldg Certificate)(For Parking Floor) |
| 348 | For Court BuildingProviding and fixing White Glazed Earthenware full stall type Urinal with P.V.C. flushing cistern of 5 liters capacity with fitting, inlet pipes and stop tap, brackets for fixing the cistern, 32 mm dia. P.V.C flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap, soil pipe connectionup to the outside face of the wall. Spec No.:As directed by Engineer in charge. SSR I.No.41.57, Sr.No.1351, P.No.271 (Jaquar / Equivalent make Confirming Green Bldg Certificate)(For First Floor) |
| 349 | For Court BuildingProviding and fixing White Glazed Earthenware full stall type Urinal with P.V.C. flushing cistern of 5 liters capacity with fitting, inlet pipes and stop tap, brackets for fixing the cistern, 32 mm dia. P.V.C flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap, soil pipe connectionup to the outside face of the wall. Spec No.:As directed by Engineer in charge. SSR I.No.41.57, Sr.No.1351, P.No.271 (Jaquar / Equivalent make Confirming Green Bldg Certificate)(For Second Floor) |
| 350 | For Court BuildingProviding and fixing White Glazed Earthenware full stall type Urinal with P.V.C. flushing cistern of 5 liters capacity with fitting, inlet pipes and stop tap, brackets for fixing the cistern, 32 mm dia. P.V.C flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap, soil pipe connectionup to the outside face of the wall. Spec No.:As directed by Engineer in charge. SSR I.No.41.57, Sr.No.1351, P.No.271 (Jaquar / Equivalent make Confirming Green Bldg Certificate)(For Third Floor) |
| 351 | For Court BuildingProviding and fixing White Glazed Earthenware full stall type Urinal with P.V.C. flushing cistern of 5 liters capacity with fitting, inlet pipes and stop tap, brackets for fixing the cistern, 32 mm dia. P.V.C flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap, soil pipe connectionup to the outside face of the wall. Spec No.:As directed by Engineer in charge. SSR I.No.41.57, Sr.No.1351, P.No.271 (Jaquar / Equivalent make Confirming Green Bldg Certificate)(For Fourth Floor) |
| 352 | For Court BuildingProviding and fixing 75 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete Spec. No.: As directed by Engineer in charge.SSR I.No.42.51, Sr.No.1422, P.No.279(For Parking Floor) |
| 353 | For Court BuildingProviding and fixing 75 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete Spec. No.: As directed by Engineer in charge.SSR I.No.42.51, Sr.No.1422, P.No.279(For First Floor) |
| 354 | For Court BuildingProviding and fixing 75 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete Spec. No.: As directed by Engineer in charge.SSR I.No.42.51, Sr.No.1422, P.No.279(For Second Floor) |
| 355 | For Court BuildingProviding and fixing 75 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete Spec. No.: As directed by Engineer in charge.SSR I.No.42.51, Sr.No.1422, P.No.279(For Third Floor) |
| 356 | For Court BuildingProviding and fixing 75 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete Spec. No.: As directed by Engineer in charge.SSR I.No.42.51, Sr.No.1422, P.No.279(For Fourth Floor) |
| 357 | For Court BuildingProviding and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete.Spec. Nos.: As directed by Engineer in charge.SSR I.Nos.42.52, Sr.Nos.1423, P.Nos.279(For Parking Floor) |
| 358 | For Court BuildingProviding and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete.Spec. Nos.: As directed by Engineer in charge.SSR I.Nos.42.52, Sr.Nos.1423, P.Nos.279(For First Floor) |
| 359 | For Court BuildingProviding and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete.Spec. Nos.: As directed by Engineer in charge.SSR I.Nos.42.52, Sr.Nos.1423, P.Nos.279(For Second Floor) |
| 360 | For Court BuildingProviding and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete.Spec. Nos.: As directed by Engineer in charge.SSR I.Nos.42.52, Sr.Nos.1423, P.Nos.279(For Third Floor) |
| 361 | For Court BuildingProviding and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete.Spec. Nos.: As directed by Engineer in charge.SSR I.Nos.42.52, Sr.Nos.1423, P.Nos.279(For Fourth Floor) |
| 362 | For Court BuildingProviding , laying and fixing ,jointing Eco- drain 110 mm SN 8 Nu- Drain Upvc pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends, tees, coupler, etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated material etc. complete.. Spec. No.: As directed by Engineer in charge.SSR I.No.43.30, Sr.No.1501, P.No.291(For Parking Floor) |
| 363 | For Court BuildingProviding , laying and fixing ,jointing Eco- drain 160 mm SN 4 Nu- Drain Upvc pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends, tees , coupler, etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated materialetc. complete Spec. No.: As directed by Engineer in charge.SSR I.No.43.31, Sr.No.1502, P.No.291(For Parking Floor) |
| 364 | For Court BuildingProviding and fixing H.D.P container one piece moulded water tank made out of low density polythyler and built corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity above 1000 to 20,000 litres Spec. No. As directed by Engineer in charge. SSR I.No.42.54, Sr.No.1425, P.No.280(ForTerraceFloor) |
| 365 | For Court BuildingProviding and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete..Spec.No.: BD.V 5 page 551 and as directed by Engineer in charge. SSR I.No.42.55, Sr.No.1426, P.No.280(For Parking Floor) |
| 366 | For Court BuildingProviding and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete..Spec.No.: BD.V 5 page 551 and as directed by Engineer in charge. SSR I.No.42.55, Sr.No.1426, P.No.280(For First Floor) |
| 367 | For Court BuildingProviding and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete..Spec.No.: BD.V 5 page 551 and as directed by Engineer in charge. SSR I.No.42.55, Sr.No.1426, P.No.280(For Second Floor) |
| 368 | For Court BuildingProviding and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete..Spec.No.: BD.V 5 page 551 and as directed by Engineer in charge. SSR I.No.42.55, Sr.No.1426, P.No.280(For Third Floor) |
| 369 | For Court BuildingProviding and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete..Spec.No.: BD.V 5 page 551 and as directed by Engineer in charge. SSR I.No.42.55, Sr.No.1426, P.No.280(For Fourth Floor) |
| 370 | For Court BuildingProviding and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.. Spec. No.: BD.V 5 page 551 and as directed by Engineer in charge. SSR I.No.42.56, Sr.No.1427, P.No.280(For Parking Floor) |
| 371 | For Court BuildingProviding and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.. Spec. No.: BD.V 5 page 551 and as directed by Engineer in charge. SSR I.No.42.56, Sr.No.1427, P.No.280(For First Floor) |
| 372 | For Court BuildingProviding and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.. Spec. No.: BD.V 5 page 551 and as directed by Engineer in charge. SSR I.No.42.56, Sr.No.1427, P.No.280(For Second Floor) |
| 373 | For Court BuildingProviding and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.. Spec. No.: BD.V 5 page 551 and as directed by Engineer in charge. SSR I.No.42.56, Sr.No.1427, P.No.280(For Third Floor) |
| 374 | For Court BuildingProviding and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.. Spec. No.: BD.V 5 page 551 and as directed by Engineer in charge. SSR I.No.42.56, Sr.No.1427, P.No.280(For Fourth Floor) |
| 375 | For Court BuildingProviding and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec.No.: BD.V 5 page 551 and as directed by Engineer in charge. SSR I.No.42.57, Sr.No.1428, P.No.280(For Parking Floor) |
| 376 | For Court BuildingProviding and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec.No.: BD.V 5 page 551 and as directed by Engineer in charge. SSR I.No.42.57, Sr.No.1428, P.No.280(For First Floor) |
| 377 | For Court BuildingProviding and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec.No.: BD.V 5 page 551 and as directed by Engineer in charge. SSR I.No.42.57, Sr.No.1428, P.No.280(For Second Floor) |
| 378 | For Court BuildingProviding and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec.No.: BD.V 5 page 551 and as directed by Engineer in charge. SSR I.No.42.57, Sr.No.1428, P.No.280(For Third Floor) |
| 379 | For Court BuildingProviding and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec.No.: BD.V 5 page 551 and as directed by Engineer in charge. SSR I.No.42.57, Sr.No.1428, P.No.280(For Fourth Floor) |
| 380 | For Court BuildingProviding and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.. Spec. No.: BD.V 5 page 551 and as directed by Engineer in charge. SSR I.No.42.58, Sr.No.1429, P.No 280(For Parking Floor) |
| 381 | For Court BuildingProviding and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.. Spec. No.: BD.V 5 page 551 and as directed by Engineer in charge. SSR I.No.42.58, Sr.No.1429, P.No 280(For First Floor) |
| 382 | For Court BuildingProviding and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.. Spec. No.: BD.V 5 page 551 and as directed by Engineer in charge. SSR I.No.42.58, Sr.No.1429, P.No 280(For Second Floor) |
| 383 | For Court BuildingProviding and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.. Spec. No.: BD.V 5 page 551 and as directed by Engineer in charge. SSR I.No.42.58, Sr.No.1429, P.No 280(For Third Floor) |
| 384 | For Court BuildingProviding and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.. Spec. No.: BD.V 5 page 551 and as directed by Engineer in charge. SSR I.No.42.58, Sr.No.1429, P.No 280(For Fourth Floor) |
| 385 | For Court BuildingProviding and fixing on walls /ceiling/ floor 40 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec.No.: BD.V 5 page 551 and as directed by Engineer in charge .SSR I.No.42.59, Sr.No.1430, P.No.280(For Parking Floor) |
| 386 | For Court BuildingProviding and fixing on walls /ceiling/ floor 40 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec.No.: BD.V 5 page 551 and as directed by Engineer in charge .SSR I.No.42.59, Sr.No.1430, P.No.280(For First Floor) |
| 387 | For Court BuildingProviding and fixing on walls /ceiling/ floor 40 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec.No.: BD.V 5 page 551 and as directed by Engineer in charge .SSR I.No.42.59, Sr.No.1430, P.No.280(For Second Floor) |
| 388 | For Court BuildingProviding and fixing on walls /ceiling/ floor 40 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec.No.: BD.V 5 page 551 and as directed by Engineer in charge .SSR I.No.42.59, Sr.No.1430, P.No.280(For Third Floor) |
| 389 | For Court BuildingProviding and fixing on walls /ceiling/ floor 40 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec.No.: BD.V 5 page 551 and as directed by Engineer in charge .SSR I.No.42.59, Sr.No.1430, P.No.280(For Fourth Floor) |
| 390 | For Court BuildingProviding and fixing on walls/ ceiling/ floor 50 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. . Spec.Nos.: BD.V 5 page 551 and as directed by Engineer in charge .SSR I.Nos.42.60, Sr.Nos.1431, P.Nos.280(For Parking Floor) |
| 391 | For Court BuildingProviding and fixing on walls/ ceiling/ floor 50 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. . Spec.Nos.: BD.V 5 page 551 and as directed by Engineer in charge .SSR I.Nos.42.60, Sr.Nos.1431, P.Nos.280(For First Floor) |
| 392 | For Court BuildingProviding and fixing on walls/ ceiling/ floor 50 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. . Spec.Nos.: BD.V 5 page 551 and as directed by Engineer in charge .SSR I.Nos.42.60, Sr.Nos.1431, P.Nos.280(For Second Floor) |
| 393 | For Court BuildingProviding and fixing on walls/ ceiling/ floor 50 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. . Spec.Nos.: BD.V 5 page 551 and as directed by Engineer in charge .SSR I.Nos.42.60, Sr.Nos.1431, P.Nos.280(For Third Floor) |
| 394 | For Court BuildingProviding and fixing on walls/ ceiling/ floor 50 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. . Spec.Nos.: BD.V 5 page 551 and as directed by Engineer in charge .SSR I.Nos.42.60, Sr.Nos.1431, P.Nos.280(For Fourth Floor) |
| 395 | For Court BuildingProviding and fixing 15 cm rigid PVC Nahani trap including PVC grating ,bend,connectingpiece of UPVC pipe up to the outside face of wall ,making the good damaged surface and testing etc. complete ( Prior approval of sample and brand by Ex. Engr. is necessary before use) Spec. No. BD.V 32 A page 551 and as directed by Engineer in charge. SSR I.No.43.18, Sr.No.1489 P.No.288(For Parking Floor) |
| 396 | For Court BuildingProviding and fixing 15 cm rigid PVC Nahani trap including PVC grating ,bend,connectingpiece of UPVC pipe up to the outside face of wall ,making the good damaged surface and testing etc. complete ( Prior approval of sample and brand by Ex. Engr. is necessary before use) Spec. No. BD.V 32 A page 551 and as directed by Engineer in charge. SSR I.No.43.18, Sr.No.1489 P.No.288(For First Floor) |
| 397 | For Court BuildingProviding and fixing 15 cm rigid PVC Nahani trap including PVC grating ,bend,connectingpiece of UPVC pipe up to the outside face of wall ,making the good damaged surface and testing etc. complete ( Prior approval of sample and brand by Ex. Engr. is necessary before use) Spec. No. BD.V 32 A page 551 and as directed by Engineer in charge. SSR I.No.43.18, Sr.No.1489 P.No.288(For Second Floor) |
| 398 | For Court BuildingProviding and fixing 15 cm rigid PVC Nahani trap including PVC grating ,bend,connectingpiece of UPVC pipe up to the outside face of wall ,making the good damaged surface and testing etc. complete ( Prior approval of sample and brand by Ex. Engr. is necessary before use) Spec. No. BD.V 32 A page 551 and as directed by Engineer in charge. SSR I.No.43.18, Sr.No.1489 P.No.288(For Third Floor) |
| 399 | For Court BuildingProviding and fixing 15 cm rigid PVC Nahani trap including PVC grating ,bend,connectingpiece of UPVC pipe up to the outside face of wall ,making the good damaged surface and testing etc. complete ( Prior approval of sample and brand by Ex. Engr. is necessary before use) Spec. No. BD.V 32 A page 551 and as directed by Engineer in charge. SSR I.No.43.18, Sr.No.1489 P.No.288(ForFourthFloor) |
| 400 | For Court BuildingProviding and fixing P.V.C. Rain water pipes of 160mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and One Number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete.. Spec No. As directed by Engineer Incharge. SSR I.No.42.85, Sr.No.1456, P.No.283(For Parking Floor) |
| 401 | For Court BuildingProviding and fixing P.V.C. Rain water pipes of 160mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and One Number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete.. Spec No. As directed by Engineer Incharge. SSR I.No.42.85, Sr.No.1456, P.No.283(For First Floor) |
| 402 | For Court BuildingProviding and fixing P.V.C. Rain water pipes of 160mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and One Number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete.. Spec No. As directed by Engineer Incharge. SSR I.No.42.85, Sr.No.1456, P.No.283(For Second Floor) |
| 403 | For Court BuildingProviding and fixing P.V.C. Rain water pipes of 160mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and One Number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete.. Spec No. As directed by Engineer Incharge. SSR I.No.42.85, Sr.No.1456, P.No.283(For Third Floor) |
| 404 | For Court BuildingProviding and fixing P.V.C. Rain water pipes of 160mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and One Number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete.. Spec No. As directed by Engineer Incharge. SSR I.No.42.85, Sr.No.1456, P.No.283(For FourthFloor) |
| 405 | For Court BuildingProviding and laying in trenches 15 mm dai. CPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete... Spec. Nos.: BD.V 5 page 551 and as directed by Engineer in charge. SSR I.Nos.42.61, Sr.Nos.1432, P.Nos.280(For Parking Floor) |
| 406 | For Court BuildingProviding and laying in trenches 20 mm dai. CPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.. Spec. Nos.: BD.V 5 page 551 and as directed by Engineer in charge. SSR I.Nos.42.62, Sr.Nos.1433, P.Nos.281(For Parking Floor) |
| 407 | For Court BuildingProviding and laying in trenches 25 mm dai. CPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.. Spec. Nos.: BD.V 5 page 551 and as directed by Engineer in charge. SSR I.Nos.42.63, Sr.Nos.1434, P.Nos.281(For Parking Floor) |
| 408 | For Court BuildingProviding and laying in trenches 32 mm dai. CPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.. Spec. Nos.: BD.V 5 page 551 and as directed by Engineer in charge. SSR I.Nos.42.64, Sr.Nos.1435, P.Nos.281 (For Parking Floor) |
| 409 | For Court BuildingProviding and laying in trenches 40mm dai. CPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.. Spec. Nos.: BD.V 5 page 551 and as directed by Engineer in charge. SSR I.Nos.42.65, Sr.Nos.1436, P.Nos.281(For Parking Floor) |
| 410 | For Court BuildingProviding and laying in trenches 50mm dai. CPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.. Spec. Nos.: BD.V 5 page 551 and as directed by Engineer in charge. SSR I.Nos.42.66, Sr.Nos.1437, P.Nos.281 (For Parking Floor) |
| 411 | For Court BuildingProviding and fixing in position UPVC ultra violet stabilized 110 mm outer diameter cowl dome confirming to I.S.-4985 including making joints with solvent cement etc. complete Spec No.:As directed by Engineer in charge. SSR I.No.43.25, Sr.No.1496, P.No.290 (For Terrace Floor) |
| 412 | For Court BuildingProviding and fixing Glass self 125 mm wide and 600 mm long with necessary chromium plated brackets providing T.W.gutties etc. complete Spec. No.:As directed by Engineer in charge .SSR I.No.43.26, Sr.No.1497, P.No.290(For Parking Floor) |
| 413 | For Court BuildingProviding and fixing Glass self 125 mm wide and 600 mm long with necessary chromium plated brackets providing T.W.gutties etc. complete Spec. No.:As directed by Engineer in charge .SSR I.No.43.26, Sr.No.1497, P.No.290(For First Floor) |
| 414 | For Court BuildingProviding and fixing Glass self 125 mm wide and 600 mm long with necessary chromium plated brackets providing T.W.gutties etc. complete Spec. No.:As directed by Engineer in charge .SSR I.No.43.26, Sr.No.1497, P.No.290(For Second Floor) |
| 415 | For Court BuildingProviding and fixing Glass self 125 mm wide and 600 mm long with necessary chromium plated brackets providing T.W.gutties etc. complete Spec. No.:As directed by Engineer in charge .SSR I.No.43.26, Sr.No.1497, P.No.290(For Third Floor) |
| 416 | For Court BuildingProviding and fixing Glass self 125 mm wide and 600 mm long with necessary chromium plated brackets providing T.W.gutties etc. complete Spec. No.:As directed by Engineer in charge .SSR I.No.43.26, Sr.No.1497, P.No.290(For Fourth Floor) |
| 417 | For Court BuildingProviding & Fixing in position, Acoustical Panelling made from 12mm thick Agro wood strips of 50, 75 7 100 mm width on 50 x 50 mm Sal-wood frame of 600 x 600 c to c having supports from wall of required length, in front of 1000 gsm synthetic wool 50 mm thick with approved coloured fabric on strips side & chicken mesh on wall side, including cost of required Cut-Outs, decorative mouldings / finishing-items / Melamine Polish & Scaffolding, as per Architectural & Acoustical Design & Instructions & Complete in all aspects. including all materials labour,finishing etc completeSpec. No. As directed by Engineer in Charge. SSR I.No.51.10, Sr.No.1835, P.No.353(For First Floor) |
| 418 | For Court BuildingProviding & Fixing in position, Acoustical Panelling made from 12mm thick Agro wood strips of 50, 75 7 100 mm width on 50 x 50 mm Sal-wood frame of 600 x 600 c to c having supports from wall of required length, in front of 1000 gsm synthetic wool 50 mm thick with approved coloured fabric on strips side & chicken mesh on wall side, including cost of required Cut-Outs, decorative mouldings / finishing-items / Melamine Polish & Scaffolding, as per Architectural & Acoustical Design & Instructions & Complete in all aspects. including all materials labour,finishing etc completeSpec. No. As directed by Engineer in Charge. SSR I.No.51.10, Sr.No.1835, P.No.353(For Second Floor) |
| 419 | For Court BuildingProviding & Fixing in position, Acoustical Panelling made from 12mm thick Agro wood strips of 50, 75 7 100 mm width on 50 x 50 mm Sal-wood frame of 600 x 600 c to c having supports from wall of required length, in front of 1000 gsm synthetic wool 50 mm thick with approved coloured fabric on strips side & chicken mesh on wall side, including cost of required Cut-Outs, decorative mouldings / finishing-items / Melamine Polish & Scaffolding, as per Architectural & Acoustical Design & Instructions & Complete in all aspects. including all materials labour,finishing etc completeSpec. No. As directed by Engineer in Charge. SSR I.No.51.10, Sr.No.1835, P.No.353(For Third Floor) |
| 420 | For Court BuildingProviding & Fixing in position, Acoustical Panelling made from 12mm thick Agro wood strips of 50, 75 7 100 mm width on 50 x 50 mm Sal-wood frame of 600 x 600 c to c having supports from wall of required length, in front of 1000 gsm synthetic wool 50 mm thick with approved coloured fabric on strips side & chicken mesh on wall side, including cost of required Cut-Outs, decorative mouldings / finishing-items / Melamine Polish & Scaffolding, as per Architectural & Acoustical Design & Instructions & Complete in all aspects. including all materials labour,finishing etc completeSpec. No. As directed by Engineer in Charge. SSR I.No.51.10, Sr.No.1835, P.No.353(For Fourth Floor) |
| 421 | For Court BuildingProviding & Fixing in position Acoustical Doors along with 150 x 150 mm teak wood frame, doors made from 50mm Teak wood frame 600 x600 c to c filled with 1000 Gsm synthetic wool 50mm thick and 3mm Tecsound from both sides, 12mm waterproof ply & veneer from both sides , including 150mm heavy duty SS hinges (Geze / Dorma or eq.) 4 no each leaf, with Door-closer (Dorma / Geze or eq.) including cost of required Cut-Outs, decorative mouldings / finishing-items / melamine polish & Scaffolding as per Architectural & Acoustical Design & Instructions & Complete in all aspects .including all materials labour,finishing etc complete Spec. No. As directed by Engineer in Charge. SSR I.No.51.05, Sr.No.1830, P.No.352(For First Floor) |
| 422 | For Court BuildingProviding & Fixing in position Acoustical Doors along with 150 x 150 mm teak wood frame, doors made from 50mm Teak wood frame 600 x600 c to c filled with 1000 Gsm synthetic wool 50mm thick and 3mm Tecsound from both sides, 12mm waterproof ply & veneer from both sides , including 150mm heavy duty SS hinges (Geze / Dorma or eq.) 4 no each leaf, with Door-closer (Dorma / Geze or eq.) including cost of required Cut-Outs, decorative mouldings / finishing-items / melamine polish & Scaffolding as per Architectural & Acoustical Design & Instructions & Complete in all aspects .including all materials labour,finishing etc complete Spec. No. As directed by Engineer in Charge. SSR I.No.51.05, Sr.No.1830, P.No.352(For Second Floor) |
| 423 | For Court BuildingProviding & Fixing in position Acoustical Doors along with 150 x 150 mm teak wood frame, doors made from 50mm Teak wood frame 600 x600 c to c filled with 1000 Gsm synthetic wool 50mm thick and 3mm Tecsound from both sides, 12mm waterproof ply & veneer from both sides , including 150mm heavy duty SS hinges (Geze / Dorma or eq.) 4 no each leaf, with Door-closer (Dorma / Geze or eq.) including cost of required Cut-Outs, decorative mouldings / finishing-items / melamine polish & Scaffolding as per Architectural & Acoustical Design & Instructions & Complete in all aspects .including all materials labour,finishing etc complete Spec. No. As directed by Engineer in Charge. SSR I.No.51.05, Sr.No.1830, P.No.352(For Third Floor) |
| 424 | For Court BuildingProviding & Fixing in position Acoustical Doors along with 150 x 150 mm teak wood frame, doors made from 50mm Teak wood frame 600 x600 c to c filled with 1000 Gsm synthetic wool 50mm thick and 3mm Tecsound from both sides, 12mm waterproof ply & veneer from both sides , including 150mm heavy duty SS hinges (Geze / Dorma or eq.) 4 no each leaf, with Door-closer (Dorma / Geze or eq.) including cost of required Cut-Outs, decorative mouldings / finishing-items / melamine polish & Scaffolding as per Architectural & Acoustical Design & Instructions & Complete in all aspects .including all materials labour,finishing etc complete Spec. No. As directed by Engineer in Charge. SSR I.No.51.05, Sr.No.1830, P.No.352(ForFourth Floor) |
| 425 | For Court BuildingProviding and Fixing of Mineral Fibre Board Acoustical Suspended Ceiling System with ultima (Bevelled Tegular) Edge Tiles of size 15mm Exposed GRID. The tiles should have Humidity Resistance (RH) of 99%, NRC 0.7, Light Reflectance 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 20mm , suitable for Green Building application, with Recycled content of 32%. The tile shall be laid on precoated G.I.channel on XL2 Clip having a web height of 32 mm with 15 mm wide T section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm and 600 mm Cross Tees with a web height of 32 mm and a load carrying capacity of 7.7 Kilograms/M2 and minimum pull out strength of 100 Kilograms.. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system. The Tile and Grid system used together should carry a 10 year warranty. products approved as per GRIHA and BS 476 etc. complete. Spec. No. As directed by Engineer in Charge. SSR I.No.38.45, Sr.No.1185, P.No.241(For First Floor) |
| 426 | For Court BuildingProviding and Fixing of Mineral Fibre Board Acoustical Suspended Ceiling System with ultima (Bevelled Tegular) Edge Tiles of size 15mm Exposed GRID. The tiles should have Humidity Resistance (RH) of 99%, NRC 0.7, Light Reflectance 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 20mm , suitable for Green Building application, with Recycled content of 32%. The tile shall be laid on precoated G.I.channel on XL2 Clip having a web height of 32 mm with 15 mm wide T section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm and 600 mm Cross Tees with a web height of 32 mm and a load carrying capacity of 7.7 Kilograms/M2 and minimum pull out strength of 100 Kilograms.. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system. The Tile and Grid system used together should carry a 10 year warranty. products approved as per GRIHA and BS 476 etc. complete. Spec. No. As directed by Engineer in Charge. SSR I.No.38.45, Sr.No.1185, P.No.241(For Second Floor) |
| 427 | For Court BuildingProviding and Fixing of Mineral Fibre Board Acoustical Suspended Ceiling System with ultima (Bevelled Tegular) Edge Tiles of size 15mm Exposed GRID. The tiles should have Humidity Resistance (RH) of 99%, NRC 0.7, Light Reflectance 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 20mm , suitable for Green Building application, with Recycled content of 32%. The tile shall be laid on precoated G.I.channel on XL2 Clip having a web height of 32 mm with 15 mm wide T section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm and 600 mm Cross Tees with a web height of 32 mm and a load carrying capacity of 7.7 Kilograms/M2 and minimum pull out strength of 100 Kilograms.. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system. The Tile and Grid system used together should carry a 10 year warranty. products approved as per GRIHA and BS 476 etc. complete. Spec. No. As directed by Engineer in Charge. SSR I.No.38.45, Sr.No.1185, P.No.241(For Third Floor) |
| 428 | For Court BuildingProviding and Fixing of Mineral Fibre Board Acoustical Suspended Ceiling System with ultima (Bevelled Tegular) Edge Tiles of size 15mm Exposed GRID. The tiles should have Humidity Resistance (RH) of 99%, NRC 0.7, Light Reflectance 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 20mm , suitable for Green Building application, with Recycled content of 32%. The tile shall be laid on precoated G.I.channel on XL2 Clip having a web height of 32 mm with 15 mm wide T section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm and 600 mm Cross Tees with a web height of 32 mm and a load carrying capacity of 7.7 Kilograms/M2 and minimum pull out strength of 100 Kilograms.. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system. The Tile and Grid system used together should carry a 10 year warranty. products approved as per GRIHA and BS 476 etc. complete. Spec. No. As directed by Engineer in Charge. SSR I.No.38.45, Sr.No.1185, P.No.241(ForFourth Floor) |
| 429 | For Court BuildingProviding and fixing 90 cm x 60 cm Granite plate engraving 10 cm. height letter,figures including painting the lefters/figures with approved colour and shade complet Spec. No. Bd.W.7 Page No.586. SSR I.No.44.12, Sr.No.1527, P.No.294(For Parking Floor) |
| 430 | For Court BuildingProviding and fixing in position alluminium strips of size 50mm x 3mm for nosing the steps including fixing with screws and raval plugs, bending and cutting to the required shape and size, finishing with paint, necessary mortar bedding of 1:3 cement mortar to get exact line and level including watering and curing etc.complete. Spec. Nos.:As directed by Engineer in charge .SSR I.Nos.44.20, Sr.Nos.1535, P.Nos.295(For Parking Floor) |
| 431 | For Court BuildingProviding and fixing in position alluminium strips of size 50mm x 3mm for nosing the steps including fixing with screws and raval plugs, bending and cutting to the required shape and size, finishing with paint, necessary mortar bedding of 1:3 cement mortar to get exact line and level including watering and curing etc.complete. Spec. Nos.:As directed by Engineer in charge .SSR I.Nos.44.20, Sr.Nos.1535, P.Nos.295(For First Floor) |
| 432 | For Court BuildingProviding and fixing in position alluminium strips of size 50mm x 3mm for nosing the steps including fixing with screws and raval plugs, bending and cutting to the required shape and size, finishing with paint, necessary mortar bedding of 1:3 cement mortar to get exact line and level including watering and curing etc.complete. Spec. Nos.:As directed by Engineer in charge .SSR I.Nos.44.20, Sr.Nos.1535, P.Nos.295(For Second Floor) |
| 433 | For Court BuildingProviding and fixing in position alluminium strips of size 50mm x 3mm for nosing the steps including fixing with screws and raval plugs, bending and cutting to the required shape and size, finishing with paint, necessary mortar bedding of 1:3 cement mortar to get exact line and level including watering and curing etc.complete. Spec. Nos.:As directed by Engineer in charge .SSR I.Nos.44.20, Sr.Nos.1535, P.Nos.295(For Third Floor) |
| 434 | For Court BuildingProviding and fixing in position alluminium strips of size 50mm x 3mm for nosing the steps including fixing with screws and raval plugs, bending and cutting to the required shape and size, finishing with paint, necessary mortar bedding of 1:3 cement mortar to get exact line and level including watering and curing etc.complete. Spec. Nos.:As directed by Engineer in charge .SSR I.Nos.44.20, Sr.Nos.1535, P.Nos.295(ForFourth Floor) |
| 435 | For Court BuildingSupply and Installation of translucent roof with DPI Flux standing seam multicell polycarbonate panel system. The system with complete assembly of co extruded UV protected multicell panels incorporated into a complete system. Co-extruded UV protected polycarbonate panel system of min 12 mm thick of 900 mm (min.) width with angular daylighting concept. Panels shall have minimum six layers with truss bridge design for higher flexibility & strength. Panels with all fixing accessories to ensure best performance for wind uplift, vibration, oil canning and visual appearance. Panels shall be manufactured with vertical standing seam at both sides of the panel. Panels shall be fixed on Purlin with snap on connectors with double tooth grip lock locking mechanism and will be secured on MS structure (will be paid Separately) with 3 One Numbers self-drilling screws & trapezoid SS fasteners holding the base of the standing seam offering best stability having a pull-out load of min. 7000N (7KN) tested as per ISO 6892:1998 and IS 1608: 2005, as per design requirement. Panels must satisfy Dart drop impact test as per IS 14443-97 shall show no sign of breakage on Polycarbonate sheets which have been exposed to UV for a min. of 500 Hours as per ASTM G 155. Panels shall not have Yellowness Index as per ASTM D 1925 of 15 units when tested on a sample exposed to UV for 500 Hours as per ASTM G 155. U value shall not be more than 1.6 W/m2K as per EN ISO 10077-2:2018. Panel shall be with additional End cap/Aluminium U/F profile/ Glazing Bar for ends as required. Panel shall be fixed over MS structural steel/MS purlin (paid separately) conforming to the detail technical specifications as per approved architectural drawings. Trained and factory authorized labour with supervision to complete the entire panel installation as per drawing & direction of the engineering in charge. Colour: As per Approval. Approved Make: FLUX by DPI Daylighting or approved equivalent The 12mm thick panels shall be used for a roofing height of upto 15 mtrs.. Spec. Nos.:As directed by Engineer in charge. SSR I.No.51.187, Sr.No.2026 P.No.239(For Parking Floor) |
| 436 | For Court BuildingSupply, fixing and installation of 4mm thick Aluminium Composite Panel (ACP) of approved colour for external cladding in combination of solid and metallic colours, including all necessary Framework, support and complete weather sealing as per architectural drawing. The Aluminium Composite Panel (ACP) should be made out of thermoplastic core of low-density polyethylene LDPE (100% virgin mix), sandwiched between two aluminium sheets of ALLOY GRADE- 5000 series, each not less than 0.50 mm thick, total thickness of aluminium composite panels not to be less than 4 mm, the exposed surface thereof shall have Stove lacquered finishing coat not less than (26 + - 2) micron (containing minimum 70% kynar 500 based PVDF) of colour and shade as per architectural design. The inside surface (facing the building exterior surface)shall have polyster based powder coating not less than 25 Micron with protective peel-off foil on the exterior face (peel off film will in no case leave any adhesive mark over the composite panel surface after it is peeled off). The supporting framework shall be made out of 50 mm X25mm X 3mm thick Aluminium section to be spaced horizontally and vertically for fixing of panel of size 900 mm X 1200 mm and fixed to the building structure as per design through 50mm X50mm X5 mm MS angle clamps prefixed to masonry or slab, columns with Hilti make anchor fastener screws. The fixing of panel to be done with the help of VHB tapes and screws and all the sealing of joints to be done with weather sealent Silicon as directed by Engineer-in-charge. (Prior permission of S.E. is necessary before inclusion of this item in estimate). Spec. Nos.:As directed by Engineer in ch(For Parking Floor) |
| 437 | For Court BuildingSupply, fixing and installation of 4mm thick Aluminium Composite Panel (ACP) of approved colour for external cladding in combination of solid and metallic colours, including all necessary Framework, support and complete weather sealing as per architectural drawing. The Aluminium Composite Panel (ACP) should be made out of thermoplastic core of low-density polyethylene LDPE (100% virgin mix), sandwiched between two aluminium sheets of ALLOY GRADE- 5000 series, each not less than 0.50 mm thick, total thickness of aluminium composite panels not to be less than 4 mm, the exposed surface thereof shall have Stove lacquered finishing coat not less than (26 + - 2) micron (containing minimum 70% kynar 500 based PVDF) of colour and shade as per architectural design. The inside surface (facing the building exterior surface)shall have polyster based powder coating not less than 25 Micron with protective peel-off foil on the exterior face (peel off film will in no case leave any adhesive mark over the composite panel surface after it is peeled off). The supporting framework shall be made out of 50 mm X25mm X 3mm thick Aluminium section to be spaced horizontally and vertically for fixing of panel of size 900 mm X 1200 mm and fixed to the building structure as per design through 50mm X50mm X5 mm MS angle clamps prefixed to masonry or slab, columns with Hilti make anchor fastener screws. The fixing of panel to be done with the help of VHB tapes and screws and all the sealing of joints to be done with weather sealent Silicon as directed by Engineer-in-charge. (Prior permission of S.E. is necessary before inclusion of this item in estimate). Spec. Nos.:As directed by Engineer in ch(For First Floor) |
| 438 | For Court BuildingSupply, fixing and installation of 4mm thick Aluminium Composite Panel (ACP) of approved colour for external cladding in combination of solid and metallic colours, including all necessary Framework, support and complete weather sealing as per architectural drawing. The Aluminium Composite Panel (ACP) should be made out of thermoplastic core of low-density polyethylene LDPE (100% virgin mix), sandwiched between two aluminium sheets of ALLOY GRADE- 5000 series, each not less than 0.50 mm thick, total thickness of aluminium composite panels not to be less than 4 mm, the exposed surface thereof shall have Stove lacquered finishing coat not less than (26 + - 2) micron (containing minimum 70% kynar 500 based PVDF) of colour and shade as per architectural design. The inside surface (facing the building exterior surface)shall have polyster based powder coating not less than 25 Micron with protective peel-off foil on the exterior face (peel off film will in no case leave any adhesive mark over the composite panel surface after it is peeled off). The supporting framework shall be made out of 50 mm X25mm X 3mm thick Aluminium section to be spaced horizontally and vertically for fixing of panel of size 900 mm X 1200 mm and fixed to the building structure as per design through 50mm X50mm X5 mm MS angle clamps prefixed to masonry or slab, columns with Hilti make anchor fastener screws. The fixing of panel to be done with the help of VHB tapes and screws and all the sealing of joints to be done with weather sealent Silicon as directed by Engineer-in-charge. (Prior permission of S.E. is necessary before inclusion of this item in estimate). Spec. Nos.:As directed by Engineer in ch(For Second Floor) |
| 439 | For Court BuildingSupply, fixing and installation of 4mm thick Aluminium Composite Panel (ACP) of approved colour for external cladding in combination of solid and metallic colours, including all necessary Framework, support and complete weather sealing as per architectural drawing. The Aluminium Composite Panel (ACP) should be made out of thermoplastic core of low-density polyethylene LDPE (100% virgin mix), sandwiched between two aluminium sheets of ALLOY GRADE- 5000 series, each not less than 0.50 mm thick, total thickness of aluminium composite panels not to be less than 4 mm, the exposed surface thereof shall have Stove lacquered finishing coat not less than (26 + - 2) micron (containing minimum 70% kynar 500 based PVDF) of colour and shade as per architectural design. The inside surface (facing the building exterior surface)shall have polyster based powder coating not less than 25 Micron with protective peel-off foil on the exterior face (peel off film will in no case leave any adhesive mark over the composite panel surface after it is peeled off). The supporting framework shall be made out of 50 mm X25mm X 3mm thick Aluminium section to be spaced horizontally and vertically for fixing of panel of size 900 mm X 1200 mm and fixed to the building structure as per design through 50mm X50mm X5 mm MS angle clamps prefixed to masonry or slab, columns with Hilti make anchor fastener screws. The fixing of panel to be done with the help of VHB tapes and screws and all the sealing of joints to be done with weather sealent Silicon as directed by Engineer-in-charge. (Prior permission of S.E. is necessary before inclusion of this item in estimate). Spec. Nos.:As directed by Engineer in ch(For Third Floor) |
| 440 | For Court BuildingSupply, fixing and installation of 4mm thick Aluminium Composite Panel (ACP) of approved colour for external cladding in combination of solid and metallic colours, including all necessary Framework, support and complete weather sealing as per architectural drawing. The Aluminium Composite Panel (ACP) should be made out of thermoplastic core of low-density polyethylene LDPE (100% virgin mix), sandwiched between two aluminium sheets of ALLOY GRADE- 5000 series, each not less than 0.50 mm thick, total thickness of aluminium composite panels not to be less than 4 mm, the exposed surface thereof shall have Stove lacquered finishing coat not less than (26 + - 2) micron (containing minimum 70% kynar 500 based PVDF) of colour and shade as per architectural design. The inside surface (facing the building exterior surface)shall have polyster based powder coating not less than 25 Micron with protective peel-off foil on the exterior face (peel off film will in no case leave any adhesive mark over the composite panel surface after it is peeled off). The supporting framework shall be made out of 50 mm X25mm X 3mm thick Aluminium section to be spaced horizontally and vertically for fixing of panel of size 900 mm X 1200 mm and fixed to the building structure as per design through 50mm X50mm X5 mm MS angle clamps prefixed to masonry or slab, columns with Hilti make anchor fastener screws. The fixing of panel to be done with the help of VHB tapes and screws and all the sealing of joints to be done with weather sealent Silicon as directed by Engineer-in-charge. (Prior permission of S.E. is necessary before inclusion of this item in estimate). Spec. Nos.:As directed by Engineer in ch(ForFourth Floor) |
| 441 | For Court BuildingProviding & Fixing 6mm thick Toughened glass Panneling with ST Series green Reflective cool glass on a frame of alluminium section of size 70mm X 53mm for green building concept & additional frame work for fireing alluminium frame etc.Complete. Spec.No. Rate sanctioned by SE PWD Nanded Vide Ltr. No. 2020-21/tender/298 Date.15-01-2021. (For First Floor) |
| 442 | For Court BuildingProviding & Fixing 6mm thick Toughened glass Panneling with ST Series green Reflective cool glass on a frame of alluminium section of size 70mm X 53mm for green building concept & additional frame work for fireing alluminium frame etc.Complete. Spec.No. Rate sanctioned by SE PWD Nanded Vide Ltr. No. 2020-21/tender/298 Date.15-01-2021. (For Second Floor) |
| 443 | For Court BuildingProviding & Fixing 6mm thick Toughened glass Panneling with ST Series green Reflective cool glass on a frame of alluminium section of size 70mm X 53mm for green building concept & additional frame work for fireing alluminium frame etc.Complete. Spec.No. Rate sanctioned by SE PWD Nanded Vide Ltr. No. 2020-21/tender/298 Date.15-01-2021. (For Third Floor) |
| 444 | For Court BuildingProviding & Fixing 6mm thick Toughened glass Panneling with ST Series green Reflective cool glass on a frame of alluminium section of size 70mm X 53mm for green building concept & additional frame work for fireing alluminium frame etc.Complete. Spec.No. Rate sanctioned by SE PWD Nanded Vide Ltr. No. 2020-21/tender/298 Date.15-01-2021. (ForFourth Floor) |
| 445 | For Court BuildingProviding and fixing lioghtening conductor system comprising of erecting AirTermination consisting of tubular copper rod of 25mm dia. 1.2 mm thick with multiple points head 1.2 mt. long ( Heavy Duty) welded or clamped to G.I. pipe pole B grade 50 mm diaof requiired length with M.S. round bnase plate 25 Cm diam and 10mm thick at bottom embeded in cement concrete 1:3:6 dfoundation of size 45 cm diam x 45 cm Height and providing earthing with copper earth plate of size 60 x 60 x 0.3 cms with cadmium plated nut bolts to fix earthing strip burried in specially prepared earth pits 1.5 metre below ground level with 40Kilogramcharcoal and salt with altemate layers of charcoal and salt and G.I.pipe 40mm dia 2 meter length burried in earthe upto earthling plate remining portion above ground level for watering and refilling comcpete Note- Copper strip fropm lightening conductor is not considered in this item... Spec. Nos.:As directed by Engineer in charge .SSR I.Nos.44.18, Sr.Nos.1533, P.Nos.295(For Parking Floor) |
| 446 | For Court BuildingProviding soak pit of size 120cm x 120cm x 120cm including excavating and filling with brick-bats. . Spec. No. Bd.V.46, Page Number 576. SSR I.No.42.19, Sr.No.1390, P.No.275(For Parking Floor) |
| 447 | For Court BuildingRWH - Shallow Percolation Pit providing, constructing 2.0m deep shallow depth percolation pit comprising of 1.0m dia pre-cast RCC rings, 300mm thick side filling around outside of RCC rings (annular space) with 40mm size boulders including filling of percolation pit up to 0.5m depth (from bottom up) with 25-75mm clean washed gravels followed by 0.5m depth of 10-25mm of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) media layer including covering with RCC slab, manhole frame & cover, PVC rungs etc. including arrangement for inlet & outlet pipe, excavation & backfilling as shown in the drawing. The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge. Spec. No. Bd.V.46, Page Number 576. SSR I.No.48.46, Sr.No.1662, P.No.317(For Parking Floor) |
| 448 | For Court BuildingADA compliant modular Multilingual and tactile Emergency evacuation map of each floor indicating the current position of the viewer saying \"YOU ARE HERE\" of 15mm height letters in red with white bacKilogramround, indicating the emergency exits, locations of fire extinguishers etc. Signs shall have a solid header with the text “EVACUATION PLAN” in contrasting uppercase letters no less than 3/4\" in height. The size of the board shall be 2ft x 2ft and shall be installed at a height of 1200mm from FFL and shall be oriented to the position of the viewer as per the direction of the site engineer Spec. No. As directed by Engineer-in-charge. SSR I.No.51.74, Sr.No.1899, P.No.371(For First Floor) |
| 449 | For Court BuildingADA compliant modular Multilingual and tactile Emergency evacuation map of each floor indicating the current position of the viewer saying \"YOU ARE HERE\" of 15mm height letters in red with white bacKilogramround, indicating the emergency exits, locations of fire extinguishers etc. Signs shall have a solid header with the text “EVACUATION PLAN” in contrasting uppercase letters no less than 3/4\" in height. The size of the board shall be 2ft x 2ft and shall be installed at a height of 1200mm from FFL and shall be oriented to the position of the viewer as per the direction of the site engineer Spec. No. As directed by Engineer-in-charge. SSR I.No.51.74, Sr.No.1899, P.No.371(For Second Floor) |
| 450 | For Court BuildingADA compliant modular Multilingual and tactile Emergency evacuation map of each floor indicating the current position of the viewer saying \"YOU ARE HERE\" of 15mm height letters in red with white bacKilogramround, indicating the emergency exits, locations of fire extinguishers etc. Signs shall have a solid header with the text “EVACUATION PLAN” in contrasting uppercase letters no less than 3/4\" in height. The size of the board shall be 2ft x 2ft and shall be installed at a height of 1200mm from FFL and shall be oriented to the position of the viewer as per the direction of the site engineer Spec. No. As directed by Engineer-in-charge. SSR I.No.51.74, Sr.No.1899, P.No.371(For Third Floor) |
| 451 | For Court BuildingADA compliant modular Multilingual and tactile Emergency evacuation map of each floor indicating the current position of the viewer saying \"YOU ARE HERE\" of 15mm height letters in red with white bacKilogramround, indicating the emergency exits, locations of fire extinguishers etc. Signs shall have a solid header with the text “EVACUATION PLAN” in contrasting uppercase letters no less than 3/4\" in height. The size of the board shall be 2ft x 2ft and shall be installed at a height of 1200mm from FFL and shall be oriented to the position of the viewer as per the direction of the site engineer Spec. No. As directed by Engineer-in-charge. SSR I.No.51.74, Sr.No.1899, P.No.371(ForFourth Floor) |
| 452 | For Court BuildingFire exit and floor identification signage as per manufacturer\"s specifications, ADA compliant and modular system Spec. No. As directed by Engineer-in-charge. SSR I.No.51.75, Sr.No.1900, P.No.371(For First Floor) |
| 453 | For Court BuildingFire exit and floor identification signage as per manufacturer\"s specifications, ADA compliant and modular system Spec. No. As directed by Engineer-in-charge. SSR I.No.51.75, Sr.No.1900, P.No.371(For Second Floor) |
| 454 | For Court BuildingFire exit and floor identification signage as per manufacturer\"s specifications, ADA compliant and modular system Spec. No. As directed by Engineer-in-charge. SSR I.No.51.75, Sr.No.1900, P.No.371(For Third Floor) |
| 455 | For Court BuildingFire exit and floor identification signage as per manufacturer\"s specifications, ADA compliant and modular system Spec. No. As directed by Engineer-in-charge. SSR I.No.51.75, Sr.No.1900, P.No.371(ForFourth Floor) |
| 456 | For Court BuildingSupplying and installing of in position the signages \" FIRE ORDER\" it should contain the following matter on 3mm thick \"Opaque\" PVC foam board of computerized cut, PVC Non-reflective self adhesive vinyle painted foam board of 3\" x 4\".Product to be ADA compliant and modular system. Spec. No. As directed by Engineer-in-charge. SSR I.No.51.76, Sr.No.1901, P.No.371(For First Floor) |
| 457 | For Court BuildingSupplying and installing of in position the signages \" FIRE ORDER\" it should contain the following matter on 3mm thick \"Opaque\" PVC foam board of computerized cut, PVC Non-reflective self adhesive vinyle painted foam board of 3\" x 4\".Product to be ADA compliant and modular system. Spec. No. As directed by Engineer-in-charge. SSR I.No.51.76, Sr.No.1901, P.No.371(For Second Floor) |
| 458 | For Court BuildingSupplying and installing of in position the signages \" FIRE ORDER\" it should contain the following matter on 3mm thick \"Opaque\" PVC foam board of computerized cut, PVC Non-reflective self adhesive vinyle painted foam board of 3\" x 4\".Product to be ADA compliant and modular system. Spec. No. As directed by Engineer-in-charge. SSR I.No.51.76, Sr.No.1901, P.No.371(For Third Floor) |
| 459 | For Court BuildingSupplying and installing of in position the signages \" FIRE ORDER\" it should contain the following matter on 3mm thick \"Opaque\" PVC foam board of computerized cut, PVC Non-reflective self adhesive vinyle painted foam board of 3\" x 4\".Product to be ADA compliant and modular system. Spec. No. As directed by Engineer-in-charge. SSR I.No.51.76, Sr.No.1901, P.No.371(ForFourth Floor) |
| 460 | For Court BuildingDesign, supply, fabrication and fixing of SS, non glare Signage board (2 ft. x 2 ft.- 1 One Number) for the accessible parking, as per the approved design and make, having 1.2mm thick SS non glare base plate and Grade 2/ Grade 1 Braille (raised dots)to be etched/ engraved and be raised 0.5mm above base plate and Upper Case San Serif words and Universal Accessibility Symbol to be etched/ engraved and signage to be installed at a height of 2100mm from the ground level using a post of MS hollow square section (50mm x 50mm) as per the installation procedure specified by the manufacturer and as per accessibility standards and up to the satisfaction of the engineer in charge. Spec. No. As directed by Engineer-in-charge. SSR I.No.51.83, Sr.No.1908, P.No.372(For Parking Floor) |
| 461 | For Court BuildingDesign, supply, fabrication and fixing acrylic multilingual Braille (raised dots) signboards of size 6\"x 9\" for room titles, designed as per the drawings issued and having 4mm thick blue acrylic base plate with Upper Case San Serif words made of white acrylic non glare cut out letters of height 15mm raised not less than 0.8mm above base plate and the equivalent word/s written in Hindi with Devnagri non glare acrylic letters of height 15mm raised not less than 0.8mm above base plate. Grade 2/ Grade 1 Braille to be integral with the sign face and be raised 0.5mm above base plate.Each signboard to be fixed as per manufacturers specifications on the wall adjoining the respective room door at a height of 1200mm from FFL and as per the directions by the engineer in charge.. Spec. No. As directed by Engineer-in-charge. SSR I.No.51.87, Sr.No.1912, P.No.373(For Parking Floor) |
| 462 | For Court BuildingDesign, supply, fabrication and fixing acrylic multilingual Braille (raised dots) signboards of size 6\"x 9\" for room titles, designed as per the drawings issued and having 4mm thick blue acrylic base plate with Upper Case San Serif words made of white acrylic non glare cut out letters of height 15mm raised not less than 0.8mm above base plate and the equivalent word/s written in Hindi with Devnagri non glare acrylic letters of height 15mm raised not less than 0.8mm above base plate. Grade 2/ Grade 1 Braille to be integral with the sign face and be raised 0.5mm above base plate.Each signboard to be fixed as per manufacturers specifications on the wall adjoining the respective room door at a height of 1200mm from FFL and as per the directions by the engineer in charge.. Spec. No. As directed by Engineer-in-charge. SSR I.No.51.87, Sr.No.1912, P.No.373(For First Floor) |
| 463 | For Court BuildingDesign, supply, fabrication and fixing acrylic multilingual Braille (raised dots) signboards of size 6\"x 9\" for room titles, designed as per the drawings issued and having 4mm thick blue acrylic base plate with Upper Case San Serif words made of white acrylic non glare cut out letters of height 15mm raised not less than 0.8mm above base plate and the equivalent word/s written in Hindi with Devnagri non glare acrylic letters of height 15mm raised not less than 0.8mm above base plate. Grade 2/ Grade 1 Braille to be integral with the sign face and be raised 0.5mm above base plate.Each signboard to be fixed as per manufacturers specifications on the wall adjoining the respective room door at a height of 1200mm from FFL and as per the directions by the engineer in charge.. Spec. No. As directed by Engineer-in-charge. SSR I.No.51.87, Sr.No.1912, P.No.373(For Second Floor) |
| 464 | For Court BuildingDesign, supply, fabrication and fixing acrylic multilingual Braille (raised dots) signboards of size 6\"x 9\" for room titles, designed as per the drawings issued and having 4mm thick blue acrylic base plate with Upper Case San Serif words made of white acrylic non glare cut out letters of height 15mm raised not less than 0.8mm above base plate and the equivalent word/s written in Hindi with Devnagri non glare acrylic letters of height 15mm raised not less than 0.8mm above base plate. Grade 2/ Grade 1 Braille to be integral with the sign face and be raised 0.5mm above base plate.Each signboard to be fixed as per manufacturers specifications on the wall adjoining the respective room door at a height of 1200mm from FFL and as per the directions by the engineer in charge.. Spec. No. As directed by Engineer-in-charge. SSR I.No.51.87, Sr.No.1912, P.No.373(For Third Floor) |
| 465 | For Court BuildingDesign, supply, fabrication and fixing acrylic multilingual Braille (raised dots) signboards of size 6\"x 9\" for room titles, designed as per the drawings issued and having 4mm thick blue acrylic base plate with Upper Case San Serif words made of white acrylic non glare cut out letters of height 15mm raised not less than 0.8mm above base plate and the equivalent word/s written in Hindi with Devnagri non glare acrylic letters of height 15mm raised not less than 0.8mm above base plate. Grade 2/ Grade 1 Braille to be integral with the sign face and be raised 0.5mm above base plate.Each signboard to be fixed as per manufacturers specifications on the wall adjoining the respective room door at a height of 1200mm from FFL and as per the directions by the engineer in charge.. Spec. No. As directed by Engineer-in-charge. SSR I.No.51.87, Sr.No.1912, P.No.373(ForFourth Floor) |
| 466 | For Court BuildingProviding and fixing board displaying information, such as \"Name of work, Tender cost, Name of Contractor, Work completion and liability period etc\", having rectangular shape of 1.20m x 0.90m size made out 18 gauge (1.25mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border / messages / symbols etc. with approved colour shade paint complete, on M.S.angle of size 35 x 35 x 3 mm frame with properly cross braced M.S. angles of size 35mmx35mmx3mm duly painted including Two M.S. angle iron posts of size 65 mm x 65 mm x 6 mm, 3.65 m long painted with alternate black and white bands of 25 cm width including all fixtures etc.and fixing the boards in 1:4:8 concrete block of size 60 cm x 60 cm x 75 cm including, excavation, refilling, transportation, and labour etc complete. Spec. No. As directed by Engineer in Charge Spec. No. MORTH 801.SSR I.No.6.36, Sr.No.284 P.No.60(For Parking loor) |
| 467 | Compound Wall :- Providing and laying Cast in situ/Ready Mix cement concrete M-15 of trap/ granite/quartzite/gneiss metal for coping to plinth or parapet, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) With fine aggregate (Crushed sand VSI Grade) Spec No. : Bd.E. 3/ Page No.288/ I.S. 456 (2000).SSR I.No.24.16, Sr.No.835, P.No.177 |
| 468 | Providing and laying in situ /Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering formwork, laying/pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)Spec. No.Bd.F.3 Page No. 298 and B.7, Page No.38. SSR I.No.25.11, Sr.No.836 P.No.1781. Compound Wall :- 15.24 cum 2. Pump house & Sump well 51000 Lt. :- 6.7 cum 3. CC Drain :- 131.28 cum 4. Parking Shed For 2 Wheelers :- 18. 14 cum5. Parking Shed For 4 Wheelers :- 14.74 cum6. Retaining Wall 3m :- 112.50 cum6. RCC gate _ 10.60 cum |
| 469 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-20oftrap/granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directedincluding steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)Spec. No. : Bd.F.5 Page No. 300 and B.7, Page.No. 38.SSR I.No.25.31, Sr.No.841, P.No.179 1. Compound Wall :- 18.92 cum 2. Pump house & Sump well 51000 Lt 1.05 cum 3. RCC GATE 12.72 cum |
| 470 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-20oftrap/granite /quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)Spec. No. Bd.F.6 Page No. 300 and B.7, Page No.38.SSR I.No.25.50, Sr.No.846, P.No.181 1. Compound Wall :- 6.14 cum 2. Pump house & Sump well 51000 Lt. :-0.95 cum3. Parking Shed For 2 Wheelers :- 3.2 cum 4. Parking Shed For 4 Wheelers :- 3.22 cum 5. RCC GATE 5.5m Wide :-5.64 cum |
| 471 | Providing fly ash brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete. Spec. No. As director by engineer incharge and BDG- 2 and 5. SSR I.No.27.13, Sr.No.900 P.No.198 1. Compound Wall :- 133.45 cum2. Pump house & Sump well 51000 Lt. :- 5.16 cum3. Security cabin 22.64 cum |
| 472 | Compound Wall :- Providing groove to required size at specified location as directed by Engineer, at junction of brick masonry wall and R.C.C beams or Column, at junction of composite masonry, including scaffolding, finishing, curing etc. complete. Spec. No. As directed by Engineer in charge. SSR I.No.32.37, Sr.No.987, P.No.212 |
| 473 | Compound Wall :- Providing and fixing 50 mm. dia. medium class G.I.pipe gate with wicket gate of approved drawing with all fixtures and fittings in two leaves with strong hold fast embedded in c.c. block at top and bottom with locking arrangement including cutting, bending, making holes and with one coat of primer etc. complete. Spec. No. As directed by Engineer in charge. SSR I.No.23.05, Sr.No.820 P.No.173 |
| 474 | Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)Spec. No. Bd.E.1 Page No. 287.SSR I.No.24.01, Sr.No.827, P.No.1751. Pump house & Sump well 51000 Lt. :- 5.58 cum2. CC Drain - 126.86 cum3. Parking Shed For 2 Wheelers - 15.12 cum4. Parking Shed For 4 Wheelers - 22.02 cum |
| 475 | Pump house & Sump well 51000 Lt. :- Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Spec No.Bd.F.8 Page No. 302 and B.7, Page No.38. SSR I.No.25.70, Sr.No.851 P.No.182 |
| 476 | Pump house & Sump well 51000 Lt. :- Providing and laying Cast in situ/Ready Mixcement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete.Withfineaggregate (Crushed sand VSI Grade)Spec.No. Bd.F.9 Page No. 303 and B.7, Page No.38.SSR I.No.26.05, Sr.No.856, P.No.184+B106:B107 |
| 477 | Pump house & Sump well 51000 Lt. :- Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting , curing , finishing and rougheningthem if special finish is to be provided and curing complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Spec. No. Bd.F.11 Page No. 304 and B.7, Page No. 38.SSR I.No.26.17, Sr.No.860, P.No.185 |
| 478 | Pump house & Sump well 51000 Lt. :- Providing and fixing 20 to 25 mm thick rough shahabad box type waterproofing for basement or underGround Floor on a base of Cement concrete 1:3:6, including sub base of 2.50 centimeter thick Cement mortar 1:3 with conceal, secrete (RMW), Algae proof or other alike waterproofing liquids, raking of joints upto 35 mm depth, filling the joints with 6 mm size crushed metal, hand grouting with cement slurry, curing and cleaning, with 7 years guarantee on court fee stamp of Rs. 100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete ) Spec. No. : Bd.J.2 Page Number 355. SSR I.No.31.12, Sr.No.948, P.No.206 |
| 479 | Pump house & Sump well 51000 Lt. :- Providing and fixing 20 to 25 mm thick rough shahabad box type waterproofing treatment to vertical outside faces of Reinforced Cement concrete walls of basement or underGround Floor including filling the gap of 25 mm between rough shahabad and R.C.C. walls with cement grout mixed with water proofing liquid Algae proof or other alike with one tile lift method, brushing the joints horizontally with cement slurry mixed with water proofing liquid for width 30 to 35 mm and sloping coping over topmost tile with cement mortar 1:3, butting the bottom most with Cement concrete 1:2:4 mixed with water proofing liquid, curing, with 7 years guarantee on court fee stamp of Rs.100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete) Spec. No. : Bd.J.2 Page Number 355. SSR I.No.31.13, Sr.No.949, P.No.207 |
| 480 | Pump house & Sump well 51000 Lt. :- Providing internal cement plaster 12mm thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. Spec. No. : Bd.L.4 Page No. 368. SSR I.No.32.03, Sr.No.957, P.No.209 |
| 481 | Pump house & Sump well 51000 Lt. :- Providing internal cement plaster 20mm thick inSingle coats in cement mortar 1:5without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete Spec. No. : Bd.L.4 Page No. 368. SSR I.No.32.06, Sr.No.960, P.No.209 |
| 482 | Pump house & Sump well 51000 Lt. :- Providing neeru finish to plastered surfaces in all positions including scaffolding and curing etc. complete.Spec. No. : Bd. L.10, Page No.370. SSR I.No.32.15, Sr.No.966, P.No.210 |
| 483 | Pump house & Sump well 51000 Lt. :- Providing fine cement finish 1.5 mm thick over green plaster surface including scaffolding curing etc. complete. Spec. No. : As directed by Engineer in charge. SSR I.No.32.21, Sr.No.972, P.No.210 |
| 484 | Pump house & Sump well 51000 Lt. :- Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints,curingandclearing etc. complete. Spec. No. Bd.M.12 Page No. 385. SSR I.No.33.40, Sr.No.1027 P.No.217 |
| 485 | Pump house & Sump well 51000 Lt. :- Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete Spec. No. Bd.M.12 Page 1 No. 385. SSR I.No.33.41, Sr.No.1028 P.No.217 |
| 486 | Pump house & Sump well 51000 Lt. :- Providing and applying three coats of water proof cement paint of approved manufacture and of approved colour tonew plastered surfaces including scaffolding if necessary, cleaning and preparing the surface, watering for two days etc. complete.Spec.One Number:Bd.O.8/Page One Number406 SSR I.No.35.16, Sr.no.1086 P.No.224 |
| 487 | Pump house & Sump well 51000 Lt. :- Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 mm with lock plate of 3.15 mm thickness reinforced with 35 x 35 x 5 mm angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth and thickness not less than 65 mm and 3.15 mm respectively with hold fast arrangements, M.S. Bracket plate 300 x 300 x 3.15 mm minimum size and shape with square bar, suspension shaft of minimum 32 mm diameter, hood cover of M.S. sheet not less than 0.9 mm thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc. complete. (I.S. 62481979) (With mechanical gear) Spec.No.BD-T-55Page Number 510 SSR I.No.39.25, Sr.No.1218 P.No.249 |
| 488 | Pump house & Sump well 51000 Lt. :- Providing and fixing in position (as per 1868 / 1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 Kilogram/Running metre. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 Kilogram/Running metre.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 Kilogram/Running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. Inter locking section 40x 18x 1.10mm atweight 0.469Kilogram/Runningmetre.andhandleand topsection40x18x1.25mm atweight o.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete. With powder coating with box Spec. No. : As directed by Engineer in charge.SSR I.No.39.43, Sr.No.1236 P.No.254 |
| 489 | Pump house & Sump well 51000 Lt. :- Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing,etc. complete.Spec. No. As directed by Engineer-In- Charge. SSR I.No.33.68, Sr.No.1052 P.No.220 |
| 490 | Pump house & Sump well 51000 Lt. :- Providing and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram/Square Metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete.Spec. No. : Bd.U. 1 Page No. 537. SSR I.No.40.01, Sr.No.1291 P.No.264 |
| 491 | Pump house & Sump well 51000 Lt. :- Providing and Fixing mat finish stainless steel (of 302 grade ) railing with top pipe of 50 mm dia. and vertical pipe of 38 mm dia at 0.60 m c/c or as required and horizontal pipes of 25 mm dia in three rows, all pipes of 2 mm thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 mm dia above newel post of 75 mm diameter etc. complete (Prior approval of sample and brand by Ex.Engineer is necessary before use Spec No.:As directed by Engineer Incharge.SSR I.No.40.08, Sr.No.1298 P.No.265 |
| 492 | Pump house & Sump well 51000 Lt. :- Boring work (including transport.) 200/215 mm diameter in the soil / gravel surface Bore diameter of 150 mm in solid rock. This includes diameter drilling work. (Wet drilling) MJP Bore Well SSR Shedule \"B\" A (item no 1) |
| 493 | Pump house & Sump well 51000 Lt. :- After completion of drilling bore well, capacity test by flushing (air lift method) is measured with 90 degree \"V\" notch. MJP Bore Well SSR Shedule \"B\" A (item no 2) |
| 494 | Pump house & Sump well 51000 Lt. :- 180 mm diameter PVC Casing pipe (8 kg / cm2) (IS 4985-1988)In exceptional circumstances / Casing pipes with a rock surface and if more than 40 feet of casing pipe is required, the casing should be used with the technical approval of the Deputy Engineer and Geologist. |
| 495 | Pump house & Sump well 51000 Lt. :- 180 mm diameter PVC Casing pipe (8 kg / cm2) (IS 4985-1988) Casing lowering, grounding |
| 496 | Pump house & Sump well 51000 Lt. :- 180 mm diameter cap for PVC pipe. |
| 497 | Internal CC Road :- Excavation for roadway in earth, soil of all sorts, sand, gravel or soft murum including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50m. and spreading for embankment or stacking as directed.Spec. No.MORTH 301 SSR I.No.2.11, Sr. No. 87 P.No.23 |
| 498 | Internal CC Road :- Providing earth work in embankment with approved materials obtained from departmental land upto lead of 50m. including all lifts, laying in layers of 20cm. to 30cm. thickness breaking clods, dressing to the required lines, curves, grades & section, watering and compaction with vibratory roller to achieve not less than 97 % of standard proctor density etc. complete ( Material obtained from departmental Land) Spec. No. MORTH 401 SSR I.No.2.27, Sr. No.100 P.No.25 |
| 499 | Internal CC Road :- Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader/ Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - I Material. Spec. No. MORTH 401 SSR I.No.3.01, Sr. No.113 P.No.27 |
| 500 | Internal CC Road :- Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate ( natural sand/ VSI grade finely washed crushed sand) conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, , cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor /by suitable means as approved by Engineer-in-charge , compacting with vibratory roller, finishing, curing andincluding preparation of sub-grade surface if required etc. complete. SSR I.No. 5.13, Sr. No.181, P.No.43 |
| 501 | Internal CC Road :- Providing and laying in situ cement concrete M30 with tremix treatment for 150 mm thickness for flooring with groove cutting of 4mm wide and 20mm deep with necessary refilling with bitumenetc. complete. SSR I.No.33.31, Sr. No. 1018, P.No.216 |
| 502 | Internal CC Road :- Providing and fixing in position TMT FE 500, tie bars precoated with anticorrosive epoxy paint of 12 mm dia. 70 cms.long and at 30.00 cm. C/C and wherever directed including handling, straightening wrapping with paper of approved quality for half length, necessary cutting, handling, straightening , supported by assembly of TMT FE 500, chairs with proper alignment etc. complete. Spec.no. MORTH 602.6.4.2 SSR I.No.5.16 Sr. No. 184, P.No.43 |
| 503 | Internal CC Road :- Supplying hard murum/ kankar at the road site, including conveying and stacking complete. SSR I.No.2.29a, Sr.No. 102 P.No.25 |
| 504 | Internal CC Road :- Spreading hard murum/ soft murrum/ gravel or kankar for side width complete. SSR I.No.2.30, Sr. No. 104 P.No.25 |
| 505 | Internal CC Road :- Compacting the hard murum side widths including laying in layers on each side with vibratory roller including artificial watering etc. complete. SSR I.No.2.31, Sr. No. 105, P.No.25 |
| 506 | Internal CC Road :- Providing and laying concrete pipes of I.S.NP. class of 300mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.. Spec. No. :Bd.V.41, Page No. 573.SSR I.No.42.09, Sr.No.1380 P.No.274 |
| 507 | Internal CC Road :- Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 1200mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. Spec. No. CD.7 Page.No. 162.SSR I.No.11.13, Sr.No.389 P.No.82 |
| 508 | Internal CC Road :- Providing and fixing kerbstone with led lighting system as per following specifications: dimensions with vertical mounting legs with 10mm horizontal square shape mild steel reinforcements. Illuminated kerb stone having visible dimensions :-500mm x 150mm x 150mm.(as per irc - 86-1983 ) 80mm legs having ms reinforcements shal be embedded in bt/concrete road surface.the kerb stone should have kerb angle of 45 degree, with rubberplugs at both ends of the kerbstones (2 nos)having load carrying capacity - vertical : 1465kg, horizontal : 2349 (certified by govt. Recoganized bodies)having thermal stability :-40 to +120 degree celcius (certified by govt. Recoganized bodies. Illuminated kerbstones including : ingrace protection and connector rating ip67, electrical wire -(as per is: 694), led strip (as per lm:80) standard. Including for electrical fixing -frp junction box consisting of - 10amp. Switch module power supply(smps)having input voltage - 230v ac, output voltage 36v dc, 2 pole mcb. Illuminated kerb stones having warranty for 3 years. illuminated kerbstone shall be fixed into cast-in-situ cement concrete of m20 grade at base, back filling and grooves, including dismantling, fixing, removal of dismantled material and cleaning etc. Complete. The colour of kerb stone shall be provided as directed by engineer in charge. Spec. No. CD.7 Page.No. 162.SSR I.No.54.05, Sr.No.2201 P.No.515 |
| 509 | CC Drain :- Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Spec No.Bd.F.8 Page No. 302 and B.7, Page No.38. SSR I.No.25.70, Sr.No.856 P.No.225 |
| 510 | CC Drain :- Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting , curing , finishing and rougheningthem if special finish is to be provided and curing complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Spec. No. Bd.F.11 Page No. 304 and B.7, Page No. 38.SSR I.No.26.17, Sr.No.865, P.No.228 |
| 511 | CC Drain :- Providing and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram/Square Metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete.Spec. No. : Bd.U. 1 Page No. 537. SSR I.No.40.01, Sr.No.1296 P.No.329 |
| 512 | Providing soling using 80 mm size trap metal in 15 cm. layer including filling voidswith Crushed sand/grit, ramming, watering etc. complete.. Spec. No. As directed by Engineer in charge. SSR I.No. 21.40, Sr.No. 754, P.No. 157 1. Parking Shed For 2 Wheelers :- 45.36 cum2. Parking Shed For 4 Wheelers :- 66.05 cum |
| 513 | Parking Shed For 2 Wheelers :- Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ granite/quartzite/gneissmetalforbedblocks,foundationblocksand suchother items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)Sepc. No. Bd.E.4 Page No. 289 and B7, Page No. 38 .SSR I.No. 24.08, Sr.No. 830, P.176 |
| 514 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-20oftrap/granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directedincluding steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)Spec. No. : Bd.F.5 Page No. 300 and B.7, Page.No. 38.SSR I.No.25.31, Sr.No.841, P.No.179 1. Parking Shed For 2 Wheelers :- 2.88 cum 2. Parking Shed For 4 Wheelers :- 6.84 cum |
| 515 | Parking Shed For 2 Wheelers :- Providing and fixing colour coated Zincalume ( R ) AZ150 ( min 150 gms/sq.mt. total on each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min.550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% aluminium 43.4% zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyester paint coat ( with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950-1050 mm effective cover width and nominal 25-30 mm deep ribs with subtle square fluting in the five pan at nominal 180-250 mm center- to-center. The end rib shall be designed for anti-capillary groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. complete. (weight of profile 4.52 Kilogram/ One Square Metre) SSR I.No.38.34 Sr.No.1174 P.No 236 |
| 516 | Parking Shed For 2 Wheelers :- Providing and fixing heavy duty inter locking concrete Coloured paving blocks of 80 mm thickness of having a strength of 300 Kilogram/Sq.cm. of approved quality and shape on a bed of crushed sand of 25 to 30 mm thick including skirting joints and cleaning etc.complete Spec. Nos. : As directed by Engineer in charge. SSR I.Nos.33.52, Sr.Nos.1039, P.Nos.218 |
| 517 | Parking Shed For 2 Wheelers :- Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete.. Spec. No. Bd.C.2 Page 1 Number 275 SSR I.No.23.01, Sr.No.816, P.No.173 |
| 518 | Parking Shed For 4 Wheelers :- Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ granite/quartzite/gneissmetalforbedblocks,foundationblocksand suchother items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)Sepc. No. Bd.E.4 Page No. 289 and B7, Page No. 38 .SSR I.No. 24.08, Sr.No. 830, P.176 |
| 519 | Parking Shed For 4 Wheelers :- Providing and fixing colour coated Zincalume ( R ) AZ150 ( min 150 gms/sq.mt. total on each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min.550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% aluminium 43.4% zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyester paint coat ( with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950-1050 mm effective cover width and nominal 25-30 mm deep ribs with subtle square fluting in the five pan at nominal 180-250 mm center- to-center. The end rib shall be designed for anti-capillary groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. complete. (weight of profile 4.52 Kilogram/ One Square Metre) SSR I.No.38.34 Sr.No.1174 P.No 236 |
| 520 | Parking Shed For 4 Wheelers :- Providing and fixing heavy duty inter locking concrete Coloured paving blocks of 80 mm thickness of having a strength of 300 Kilogram/Sq.cm. of approved quality and shape on a bed of crushed sand of 25 to 30 mm thick including skirting joints and cleaning etc.complete Spec. Nos. : As directed by Engineer in charge. SSR I.Nos.33.52, Sr.Nos.1039, P.Nos.218 |
| 521 | Parking Shed For 4 Wheelers :- Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete.. Spec. No. Bd.C.2 Page 1 Number 275 SSR I.No.23.01, Sr.No.816, P.No.173 |
| 522 | Retaining Wall 3m:- Providing and laying in situ / ready mix M-20 plain cement concrete of trap /granite/quartzite/ gneiss metal for cast in citu piers, abutment, returns, wings etc. including provision of \"V\" shaped false joints to form suitable panels on the faces to approve design with compacting by vibrating and curing complete, including plywood/steel form work centering ( excluding dewatering by means of pump) and including bailling out water and curing finishing in CM 1:3 etc. complete. as directed by engineer in charge basic rate shall be increased for height above 5..00 m in followinh mannersb) Height upto 5 M. (With Batch Mix Plant) With fully automatic micro processor based PLC with SCADA enable with fine agreegates of required specifications ( VSI sand finely washed etc )i) Height up to 5 m, normal rate.ii) Height 5 to 7.50 m, add 5 percent extra over basic rate.iii) Height 7.50 to 10 m, 7.50 percent extra.iv) Over 10 m Height, add 10 percent extra for every 2.50m rise..Spec. No. : MORT&H (5th Rev.)1700, 2204. No. 38.SSR I.No.17.43, Sr.No.634, P.No.165 |
| 523 | Retaining Wall 3m :- Providing and laying weep holes of 100 mm diameter PVC pipes as per drawing for abutment returns, return walls etc. Complete. Spec. No. MORT&H (5th Rev.) 2705, 2706. SSR I.No.17.37, Sr.No.623, P.No.99 |
| 524 | RCC GATE 5.5m Wide :- Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting , curing , finishing and rougheningthem if special finish is to be provided and curing complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Spec. No. Bd.F.11 Page No. 304 and B.7, Page No. 38.SSR I.No.26.17, Sr.No.860, P.No.185 ( Ground Floor ) |
| 525 | RCC GATE 5.5m Wide :- Providing and applying Texture plaster with finishing with texture material of approved make in 3 to 4 millimeter thickness on previously plastered surface, including Plaster Groove 6mm thickness or Tape Grooves 35 to 45 mm thickness or as required,inallposition including preparing the surface, scaffolding etc. complete. Spec. No. : Bd.L.7 Page 1 No. 369. SSR I.No.32.32, Sr.No.963, P.No.211( Ground Floor ) |
| 526 | RCC GATE 5.5m Wide :- Providing patti/ band 75mm wide on plastered surface 12 mm to 15 mm thick in C.M. 1:3 line and level including neat finishing scaffolding curing etc. complete. . Spec. No. Bd.L. Page No. SSRSSR I.No.32.23, Sr.No.974, P.No.210 ( Ground Floor ) |
| 527 | RCC GATE 5.5m Wide :- Providing patti/ band 100mm wide on plastered surface 12 mm to 15 mm thick in C.M. 1:3 line and level including neat finishing scaffolding curing etc. complete. Spec. No. As directed by Engineer in charge. SSR I.No.32.24, Sr.No.975, P.No.210 ( Ground Floor ) |
| 528 | RCC GATE 5.5m Wide :- Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete. Spec No.: As directed by Engineer in charge. SSR I.No.32.26, Sr.No.977, P.No.210 ( Ground Floor ) |
| 529 | RCC GATE 5.5m Wide :- Providing groove to required size at specified location as directed by Engineer, at junction of brick masonry wall and R.C.C beams or Column, at junction of composite masonry, including scaffolding, finishing, curing etc. complete. Spec. No. As directed by Engineer in charge. SSR I.No.32.37, Sr.No.987, P.No.212 ( Ground Floor ) |
| 530 | Furniture :- Providing and Fixing Rollar Blinds AMI Make or approved make & shade of 38mm round Aluminium channel with Blackout fabric & telting with chain (Ball) system with all necessary fixtures and fitting etc. complete. (Sample to be final by Engineer In-charge prior execution of work). SSR I.No.51.19 Sr.No.1844 Page No.355 (Ground Floor) |
| 531 | Furniture :- Providing and Fixing Rollar Blinds AMI Make or approved make & shade of 38mm round Aluminium channel with Blackout fabric & telting with chain (Ball) system with all necessary fixtures and fitting etc. complete. (Sample to be final by Engineer In-charge prior execution of work). SSR I.No.51.19 Sr.No.1844 Page No.355 (First Floor) |
| 532 | Furniture :- Providing and Fixing Rollar Blinds AMI Make or approved make & shade of 38mm round Aluminium channel with Blackout fabric & telting with chain (Ball) system with all necessary fixtures and fitting etc. complete. (Sample to be final by Engineer In-charge prior execution of work). SSR I.No.51.19 Sr.No.1844 Page No.355 (Second Floor) |
| 533 | Furniture :- Providing and Fixing Rollar Blinds AMI Make or approved make & shade of 38mm round Aluminium channel with Blackout fabric & telting with chain (Ball) system with all necessary fixtures and fitting etc. complete. (Sample to be final by Engineer In-charge prior execution of work). SSR I.No.51.19 Sr.No.1844 Page No.355 (Third Floor) |
| 534 | Furniture :- Providing and Fixing Rollar Blinds AMI Make or approved make & shade of 38mm round Aluminium channel with Blackout fabric & telting with chain (Ball) system with all necessary fixtures and fitting etc. complete. (Sample to be final by Engineer In-charge prior execution of work). SSR I.No.51.19 Sr.No.1844 Page No.355 (Fourth Floor) |
| 535 | Furniture :- Credestal @ 1200Lx450Lx650HT Providing & Fixing of LOW HEIGHT CREDESTAL @ 1200L X 450D X 650H :- To be made out of Membrane Finish ( 2 Openable Shutter & 3 Drawer Pedestal in between )as per drawing. As directed by Engineer-incharge SSR I.No.51.23 Sr.No.1848 Page No.355 (First Floor) |
| 536 | Furniture :- Credestal @ 1200Lx450Lx650HT Providing & Fixing of LOW HEIGHT CREDESTAL @ 1200L X 450D X 650H :- To be made out of Membrane Finish ( 2 Openable Shutter & 3 Drawer Pedestal in between )as per drawing. As directed by Engineer-incharge SSR I.No.51.23 Sr.No.1848 Page No.355 (Second Floor) |
| 537 | Furniture :- Credestal @ 1200Lx450Lx650HT Providing & Fixing of LOW HEIGHT CREDESTAL @ 1200L X 450D X 650H :- To be made out of Membrane Finish ( 2 Openable Shutter & 3 Drawer Pedestal in between )as per drawing. As directed by Engineer-incharge SSR I.No.51.23 Sr.No.1848 Page No.355 (Third Floor) |
| 538 | Furniture :- Credestal @ 1200Lx450Lx650HT Providing & Fixing of LOW HEIGHT CREDESTAL @ 1200L X 450D X 650H :- To be made out of Membrane Finish ( 2 Openable Shutter & 3 Drawer Pedestal in between )as per drawing. As directed by Engineer-incharge SSR I.No.51.23 Sr.No.1848 Page No.355 (Fourth Floor) |
| 539 | Furniture :- 3 DRAWER PEDESTAL UNIT @ 392L x 450D x 680Ht. mm. 3 DRAWER PEDESTAL UNIT having overall size 392L x 450D x 680Ht. mm. with central lock and key. 3 Drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminated particle board. As directed by Engineer-incharge SSR I.No.51.34 Sr.No.1859 page No.358 (First Floor) |
| 540 | Furniture :- 3 DRAWER PEDESTAL UNIT @ 392L x 450D x 680Ht. mm. 3 DRAWER PEDESTAL UNIT having overall size 392L x 450D x 680Ht. mm. with central lock and key. 3 Drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminated particle board. As directed by Engineer-incharge SSR I.No.51.34 Sr.No.1859 page No.358 (Second Floor) |
| 541 | Furniture :- 3 DRAWER PEDESTAL UNIT @ 392L x 450D x 680Ht. mm. 3 DRAWER PEDESTAL UNIT having overall size 392L x 450D x 680Ht. mm. with central lock and key. 3 Drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminated particle board. As directed by Engineer-incharge SSR I.No.51.34 Sr.No.1859 page No.358 (Third Floor) |
| 542 | Furniture :- 3 DRAWER PEDESTAL UNIT @ 392L x 450D x 680Ht. mm. 3 DRAWER PEDESTAL UNIT having overall size 392L x 450D x 680Ht. mm. with central lock and key. 3 Drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminated particle board. As directed by Engineer-incharge SSR I.No.51.34 Sr.No.1859 page No.358 (Fourth Floor) |
| 543 | Furniture :- Low Height Openable Storage @ 900Lx450x750HT Providing and fixing Openable Steel Storage of 900 x 450 x 750Ht, with 2 adjustable shelves, Complete body & shutter made in 0.8 mm thick & Top in 2 mm thick CRCA, 2 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns. with 25 mm. thk additional Top on top of storage as as per drawing As directed by Engineer-incharge SSR I.No.51.35 Sr.No.1860 Page No.358 (First Floor) |
| 544 | Furniture :- Low Height Openable Storage @ 900Lx450x750HT Providing and fixing Openable Steel Storage of 900 x 450 x 750Ht, with 2 adjustable shelves, Complete body & shutter made in 0.8 mm thick & Top in 2 mm thick CRCA, 2 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns. with 25 mm. thk additional Top on top of storage as as per drawing As directed by Engineer-incharge SSR I.No.51.35 Sr.No.1860 Page No.358 (Second Floor) |
| 545 | Furniture :- Low Height Openable Storage @ 900Lx450x750HT Providing and fixing Openable Steel Storage of 900 x 450 x 750Ht, with 2 adjustable shelves, Complete body & shutter made in 0.8 mm thick & Top in 2 mm thick CRCA, 2 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns. with 25 mm. thk additional Top on top of storage as as per drawing As directed by Engineer-incharge SSR I.No.51.35 Sr.No.1860 Page No.358 (Third Floor) |
| 546 | Furniture :- Low Height Openable Storage @ 900Lx450x750HT Providing and fixing Openable Steel Storage of 900 x 450 x 750Ht, with 2 adjustable shelves, Complete body & shutter made in 0.8 mm thick & Top in 2 mm thick CRCA, 2 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns. with 25 mm. thk additional Top on top of storage as as per drawing As directed by Engineer-incharge SSR I.No.51.35 Sr.No.1860 Page No.358 (Fourth Floor) |
| 547 | Furniture :- Full Height Steel Storage @ 750Lx450Dx2100HT Providing and fixing Openable Steel Storage of 750 x 450 x 2100Ht, with 4 adjustable shelves, Complete body & shutter made in 0.8 mm thick & Top in 2 mm thick CRCA, 4 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns as as per drawing. As directed by Engineer-incharge SSR I.No.51.37 Sr.No.1862 Page No.359 (First Floor) |
| 548 | Furniture :- Full Height Steel Storage @ 750Lx450Dx2100HT Providing and fixing Openable Steel Storage of 750 x 450 x 2100Ht, with 4 adjustable shelves, Complete body & shutter made in 0.8 mm thick & Top in 2 mm thick CRCA, 4 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns as as per drawing. As directed by Engineer-incharge SSR I.No.51.37 Sr.No.1862 Page No.359 (Second Floor) |
| 549 | Furniture :- Full Height Steel Storage @ 750Lx450Dx2100HT Providing and fixing Openable Steel Storage of 750 x 450 x 2100Ht, with 4 adjustable shelves, Complete body & shutter made in 0.8 mm thick & Top in 2 mm thick CRCA, 4 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns as as per drawing. As directed by Engineer-incharge SSR I.No.51.37 Sr.No.1862 Page No.359 (Third Floor) |
| 550 | Furniture :- Full Height Steel Storage @ 750Lx450Dx2100HT Providing and fixing Openable Steel Storage of 750 x 450 x 2100Ht, with 4 adjustable shelves, Complete body & shutter made in 0.8 mm thick & Top in 2 mm thick CRCA, 4 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns as as per drawing. As directed by Engineer-incharge SSR I.No.51.37 Sr.No.1862 Page No.359 (Fourth Floor) |
| 551 | Furniture :- Book Case with Glass Shutter @ 825Lx300Dx1650HT Providing & Fixing of Book Case with Glass Shutter @ 825Lx300Dx1650HT:- To be made out of complete body & in 0.7mm thick CRCA & Shutter in 1.2mm thick CRCA with glass pannel in Powder coating finish as per drawing. SSR I.No.51.39 Sr.No.1864 Page No.359 (First Floor) |
| 552 | Furniture :- Book Case with Glass Shutter @ 825Lx300Dx1650HT Providing & Fixing of Book Case with Glass Shutter @ 825Lx300Dx1650HT:- To be made out of complete body & in 0.7mm thick CRCA & Shutter in 1.2mm thick CRCA with glass pannel in Powder coating finish as per drawing. SSR I.No.51.39 Sr.No.1864 Page No.359 (Second Floor) |
| 553 | Furniture :- Book Case with Glass Shutter @ 825Lx300Dx1650HT Providing & Fixing of Book Case with Glass Shutter @ 825Lx300Dx1650HT:- To be made out of complete body & in 0.7mm thick CRCA & Shutter in 1.2mm thick CRCA with glass pannel in Powder coating finish as per drawing. SSR I.No.51.39 Sr.No.1864 Page No.359 (Third Floor) |
| 554 | Furniture :- Book Case with Glass Shutter @ 825Lx300Dx1650HT Providing & Fixing of Book Case with Glass Shutter @ 825Lx300Dx1650HT:- To be made out of complete body & in 0.7mm thick CRCA & Shutter in 1.2mm thick CRCA with glass pannel in Powder coating finish as per drawing. SSR I.No.51.39 Sr.No.1864 Page No.359 (Fourth Floor) |
| 555 | Furniture :- Wardrobe with Mirror @ 900LX 600DX 1965HProviding and Fixing Wardrobe with Mirror of size 900LX 600DX 1965H The wardrobe side panels and doors are made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The shelves are made of 18mm thick Prelam Particle Board with decorative laminate on both sides. The top is made of 36mm prelam particle board with decorative laminate on both sides. (18mm Prelam Particle board and 18mm batons on all sides to achieve 36mm overall thickness). The exposed edges of the top are sealed with 2mm thick PVC edge Banding. The top most part of the wardrobe has an aluminum hanger rod of EBCO make. One drawer of size 400(W) x 150(H) x 450 (D) made of 18mm thick prelam Particle Board has been considered. The drawer will have a multipurpose lock of EBCO premium make. The wardrobe handles are Satin SS finish of 160mm pitch. The wardrobe has a multipurpose lock of EBCO make. All hinges considered are Hettich make. Necessary good quality hardwares have been considered as required.SSR I.No.51.57 Sr.No.1882 Page No.367 (First Floor) |
| 556 | Furniture :- Wardrobe with Mirror @ 900LX 600DX 1965HProviding and Fixing Wardrobe with Mirror of size 900LX 600DX 1965H The wardrobe side panels and doors are made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The shelves are made of 18mm thick Prelam Particle Board with decorative laminate on both sides. The top is made of 36mm prelam particle board with decorative laminate on both sides. (18mm Prelam Particle board and 18mm batons on all sides to achieve 36mm overall thickness). The exposed edges of the top are sealed with 2mm thick PVC edge Banding. The top most part of the wardrobe has an aluminum hanger rod of EBCO make. One drawer of size 400(W) x 150(H) x 450 (D) made of 18mm thick prelam Particle Board has been considered. The drawer will have a multipurpose lock of EBCO premium make. The wardrobe handles are Satin SS finish of 160mm pitch. The wardrobe has a multipurpose lock of EBCO make. All hinges considered are Hettich make. Necessary good quality hardwares have been considered as required.SSR I.No.51.57 Sr.No.1882 Page No.367 (Second Floor) |
| 557 | Furniture :- Wardrobe with Mirror @ 900LX 600DX 1965HProviding and Fixing Wardrobe with Mirror of size 900LX 600DX 1965H The wardrobe side panels and doors are made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The shelves are made of 18mm thick Prelam Particle Board with decorative laminate on both sides. The top is made of 36mm prelam particle board with decorative laminate on both sides. (18mm Prelam Particle board and 18mm batons on all sides to achieve 36mm overall thickness). The exposed edges of the top are sealed with 2mm thick PVC edge Banding. The top most part of the wardrobe has an aluminum hanger rod of EBCO make. One drawer of size 400(W) x 150(H) x 450 (D) made of 18mm thick prelam Particle Board has been considered. The drawer will have a multipurpose lock of EBCO premium make. The wardrobe handles are Satin SS finish of 160mm pitch. The wardrobe has a multipurpose lock of EBCO make. All hinges considered are Hettich make. Necessary good quality hardwares have been considered as required.SSR I.No.51.57 Sr.No.1882 Page No.367 (Third Floor) |
| 558 | Furniture :- Wardrobe with Mirror @ 900LX 600DX 1965HProviding and Fixing Wardrobe with Mirror of size 900LX 600DX 1965H The wardrobe side panels and doors are made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The shelves are made of 18mm thick Prelam Particle Board with decorative laminate on both sides. The top is made of 36mm prelam particle board with decorative laminate on both sides. (18mm Prelam Particle board and 18mm batons on all sides to achieve 36mm overall thickness). The exposed edges of the top are sealed with 2mm thick PVC edge Banding. The top most part of the wardrobe has an aluminum hanger rod of EBCO make. One drawer of size 400(W) x 150(H) x 450 (D) made of 18mm thick prelam Particle Board has been considered. The drawer will have a multipurpose lock of EBCO premium make. The wardrobe handles are Satin SS finish of 160mm pitch. The wardrobe has a multipurpose lock of EBCO make. All hinges considered are Hettich make. Necessary good quality hardwares have been considered as required.SSR I.No.51.57 Sr.No.1882 Page No.367 (Fourth Floor) |
| 559 | Furniture :- Tea Table 900mm X 750mm X 450mm for m.s. ante chamber Providing And Fixing OfTea Table 900mm X 750mm X 450mm With 12mm Thick Colour Eitched Tempered Glass With Bevelled Drawing Made Out Of 18mm Thick Waterproofing Ply. The Outer Laces To Be Finished With High Quality 4 Mm Thik Veneer Or 1 Mm Thik Mica Etc. . SSR I.No.51.54 Sr.No.1879 Page No.366 (First Floor) |
| 560 | Furniture :- Tea Table 900mm X 750mm X 450mm for m.s. ante chamber Providing And Fixing OfTea Table 900mm X 750mm X 450mm With 12mm Thick Colour Eitched Tempered Glass With Bevelled Drawing Made Out Of 18mm Thick Waterproofing Ply. The Outer Laces To Be Finished With High Quality 4 Mm Thik Veneer Or 1 Mm Thik Mica Etc. . SSR I.No.51.54 Sr.No.1879 Page No.366 (Second Floor) |
| 561 | Furniture :- Tea Table 900mm X 750mm X 450mm for m.s. ante chamber Providing And Fixing OfTea Table 900mm X 750mm X 450mm With 12mm Thick Colour Eitched Tempered Glass With Bevelled Drawing Made Out Of 18mm Thick Waterproofing Ply. The Outer Laces To Be Finished With High Quality 4 Mm Thik Veneer Or 1 Mm Thik Mica Etc. . SSR I.No.51.54 Sr.No.1879 Page No.366 (Third Floor) |
| 562 | Furniture :- Tea Table 900mm X 750mm X 450mm for m.s. ante chamber Providing And Fixing OfTea Table 900mm X 750mm X 450mm With 12mm Thick Colour Eitched Tempered Glass With Bevelled Drawing Made Out Of 18mm Thick Waterproofing Ply. The Outer Laces To Be Finished With High Quality 4 Mm Thik Veneer Or 1 Mm Thik Mica Etc. . SSR I.No.51.54 Sr.No.1879 Page No.366 (Fourth Floor) |
| 563 | Furniture :- Providing & Arrangemnt of High Back, Synchronized Mechanism with Multiple Locking, Adjustable Armrest, Gaslift for Seat height adjustment, Standard 5-prong P/Nylon Basewith Leatherite Upholstery SSR.I.No.51.40 Sr.No.1865 Page No.359 (First Floor) |
| 564 | Furniture :- Providing & Arrangemnt of High Back, Synchronized Mechanism with Multiple Locking, Adjustable Armrest, Gaslift for Seat height adjustment, Standard 5-prong P/Nylon Basewith Leatherite Upholstery SSR.I.No.51.40 Sr.No.1865 Page No.359 (Second Floor) |
| 565 | Furniture :- Providing & Arrangemnt of High Back, Synchronized Mechanism with Multiple Locking, Adjustable Armrest, Gaslift for Seat height adjustment, Standard 5-prong P/Nylon Basewith Leatherite Upholstery SSR.I.No.51.40 Sr.No.1865 Page No.359 (Third Floor) |
| 566 | Furniture :- Providing & Arrangemnt of High Back, Synchronized Mechanism with Multiple Locking, Adjustable Armrest, Gaslift for Seat height adjustment, Standard 5-prong P/Nylon Basewith Leatherite Upholstery SSR.I.No.51.40 Sr.No.1865 Page No.359 (Fourth Floor) |
| 567 | Furniture :- Providing & Arrangemnt of High Back Chair - TILT MECHANISM WITH MULTILOCKING, HIGH DENSITY CUSHION ON SEAT COMPOSITE LEATHER WITH METALLIC SILVER FINISH BASE AND ARMS WITH P.U.CASTORS GASLIFT FOR HEIGHT ADJUSTMENT. SSR.I.No.51.41 Sr.No.1866 Page No.359 (First Floor) |
| 568 | Furniture :- Providing & Arrangemnt of High Back Chair - TILT MECHANISM WITH MULTILOCKING, HIGH DENSITY CUSHION ON SEAT COMPOSITE LEATHER WITH METALLIC SILVER FINISH BASE AND ARMS WITH P.U.CASTORS GASLIFT FOR HEIGHT ADJUSTMENT. SSR.I.No.51.41 Sr.No.1866 Page No.359 (Second Floor) |
| 569 | Furniture :- Providing & Arrangemnt of High Back Chair - TILT MECHANISM WITH MULTILOCKING, HIGH DENSITY CUSHION ON SEAT COMPOSITE LEATHER WITH METALLIC SILVER FINISH BASE AND ARMS WITH P.U.CASTORS GASLIFT FOR HEIGHT ADJUSTMENT. SSR.I.No.51.41 Sr.No.1866 Page No.359 (Third Floor) |
| 570 | Furniture :- Providing & Arrangemnt of High Back Chair - TILT MECHANISM WITH MULTILOCKING, HIGH DENSITY CUSHION ON SEAT COMPOSITE LEATHER WITH METALLIC SILVER FINISH BASE AND ARMS WITH P.U.CASTORS GASLIFT FOR HEIGHT ADJUSTMENT. SSR.I.No.51.41 Sr.No.1866 Page No.359 (Fourth Floor) |
| 571 | Furniture :- Providing & Arrangemnt of MId Back, Normal Syncro Mechanism , Fixed Armrest, Gaslift for Seat height adjustment, Standard 5-prong/Nylon Base with Leather Upholstery SSR I.No.51.42 Sr.No.1867 Page No.359 (First Floor) |
| 572 | Furniture :- Providing & Arrangemnt of MId Back, Normal Syncro Mechanism , Fixed Armrest, Gaslift for Seat height adjustment, Standard 5-prong/Nylon Base with Leather Upholstery SSR I.No.51.42 Sr.No.1867 Page No.359 (Second Floor) |
| 573 | Furniture :- Providing & Arrangemnt of MId Back, Normal Syncro Mechanism , Fixed Armrest, Gaslift for Seat height adjustment, Standard 5-prong/Nylon Base with Leather Upholstery SSR I.No.51.42 Sr.No.1867 Page No.359 (Third Floor) |
| 574 | Furniture :- Providing & Arrangemnt of MId Back, Normal Syncro Mechanism , Fixed Armrest, Gaslift for Seat height adjustment, Standard 5-prong/Nylon Base with Leather Upholstery SSR I.No.51.42 Sr.No.1867 Page No.359 (Fourth Floor) |
| 575 | Furniture :- Providing & Arrangemnt of Mid Back, ECO CTS Mechanism , Fixed Armrest, Gaslift for Seat height adjustment, Standard 5-prong P/Nylon Base with Fabric UpholsterySSR I.No.51.43 Sr.No.1868 Page No.359 (First Floor) |
| 576 | Furniture :- Providing & Arrangemnt of Mid Back, ECO CTS Mechanism , Fixed Armrest, Gaslift for Seat height adjustment, Standard 5-prong P/Nylon Base with Fabric UpholsterySSR I.No.51.43 Sr.No.1868 Page No.359 (Second Floor) |
| 577 | Furniture :- Providing & Arrangemnt of Mid Back, ECO CTS Mechanism , Fixed Armrest, Gaslift for Seat height adjustment, Standard 5-prong P/Nylon Base with Fabric UpholsterySSR I.No.51.43 Sr.No.1868 Page No.359 (Third Floor) |
| 578 | Furniture :- Providing & Arrangemnt of Mid Back, ECO CTS Mechanism , Fixed Armrest, Gaslift for Seat height adjustment, Standard 5-prong P/Nylon Base with Fabric UpholsterySSR I.No.51.43 Sr.No.1868 Page No.359 (Fourth Floor) |
| 579 | Furniture :- Public Seating Chair. - 3 Seater Providing and Fixing 3 seater Public seating chair made of complete metal with Legs in Crome finish and seates in silver powder coating finish. SSR I.No.51.44 Sr.No.1869 Page No 359 (Ground Floor) |
| 580 | Furniture :- Public Seating Chair. - 3 Seater Providing and Fixing 3 seater Public seating chair made of complete metal with Legs in Crome finish and seates in silver powder coating finish. SSR I.No.51.44 Sr.No.1869 Page No 359 (First Floor) |
| 581 | Furniture :- Public Seating Chair. - 3 Seater Providing and Fixing 3 seater Public seating chair made of complete metal with Legs in Crome finish and seates in silver powder coating finish. SSR I.No.51.44 Sr.No.1869 Page No 359 (Second Floor) |
| 582 | Furniture :- Public Seating Chair. - 3 Seater Providing and Fixing 3 seater Public seating chair made of complete metal with Legs in Crome finish and seates in silver powder coating finish. SSR I.No.51.44 Sr.No.1869 Page No 359 (Third Floor) |
| 583 | Furniture :- Public Seating Chair. - 3 Seater Providing and Fixing 3 seater Public seating chair made of complete metal with Legs in Crome finish and seates in silver powder coating finish. SSR I.No.51.44 Sr.No.1869 Page No 359 (Fourth Floor) |
| 584 | Furniture :- Alluminium foldable ladder for store Providing & Fixing Foldable Alluminum Ladder 1500 mm. Ht. SSR I.No.51.52 Sr.No.1877 Page No.365 (First Floor) |
| 585 | Furniture :- Alluminium foldable ladder for store Providing & Fixing Foldable Alluminum Ladder 1500 mm. Ht. SSR I.No.51.52 Sr.No.1877 Page No.365 (Second Floor) |
| 586 | Furniture :- Alluminium foldable ladder for store Providing & Fixing Foldable Alluminum Ladder 1500 mm. Ht. SSR I.No.51.52 Sr.No.1877 Page No.365 (Third Floor) |
| 587 | Furniture :- Alluminium foldable ladder for store Providing & Fixing Foldable Alluminum Ladder 1500 mm. Ht. SSR I.No.51.52 Sr.No.1877 Page No.365 (Fourth Floor) |
| 588 | Furniture :- Sofa Set 3+1+1 Providing & fixing Sofa Set 3+1+1 Brown and Cream leather DIMENSION Length: 182.5 (cms) Breadth (cms): 100 (cms)Height (cms): 100 (cms) Weight (Kilograms): 66 (Kilogram) Seating Capacity: Five Seat SSR I.No.51.53 Sr.No 1878 Page No.366 (First Floor) |
| 589 | Furniture :- Sofa Set 3+1+1 Providing & fixing Sofa Set 3+1+1 Brown and Cream leather DIMENSION Length: 182.5 (cms) Breadth (cms): 100 (cms)Height (cms): 100 (cms) Weight (Kilograms): 66 (Kilogram) Seating Capacity: Five Seat SSR I.No.51.53 Sr.No 1878 Page No.366 (Second Floor) |
| 590 | Furniture :- Sofa Set 3+1+1 Providing & fixing Sofa Set 3+1+1 Brown and Cream leather DIMENSION Length: 182.5 (cms) Breadth (cms): 100 (cms)Height (cms): 100 (cms) Weight (Kilograms): 66 (Kilogram) Seating Capacity: Five Seat SSR I.No.51.53 Sr.No 1878 Page No.366 (Third Floor) |
| 591 | Furniture :- Sofa Set 3+1+1 Providing & fixing Sofa Set 3+1+1 Brown and Cream leather DIMENSION Length: 182.5 (cms) Breadth (cms): 100 (cms)Height (cms): 100 (cms) Weight (Kilograms): 66 (Kilogram) Seating Capacity: Five Seat SSR I.No.51.53 Sr.No 1878 Page No.366 (Fourth Floor) |
| 592 | Furniture :- 12 Seater Reading Table for Library @ 3600Lx1200Dx750HT Providing and Fixing 12 Seater Reading Table for Liberary @ 3600Lx1200Dx750HT Top: made from 25 mm Prelaminated Particle board. All edges are covered by 2 mm. Thk. PVC edge bands glued by hot melt glue applied by auto edge banding machine. Gable Ends : made from 25 mm Prelaminated Particle board. All edges are covered by 2 mm. Thk. PVC edge bands glued by hot melt glue applied by auto edge banding machine. Modesty panel : Made from 18mm both side prelaminated particle boards.All edges are covered by 0.8mm PVC edge bands glued by hot melt glue applied by auto edge banding machine. As directed by Engineer-in-charge .SSR I.No.51.33 Sr.No 1858 Page No.358 (Third Floor) |
| 593 | Furniture :- 12 Seater Reading Table for Library @ 3600Lx1200Dx750HT Providing and Fixing 12 Seater Reading Table for Liberary @ 3600Lx1200Dx750HT Top: made from 25 mm Prelaminated Particle board. All edges are covered by 2 mm. Thk. PVC edge bands glued by hot melt glue applied by auto edge banding machine. Gable Ends : made from 25 mm Prelaminated Particle board. All edges are covered by 2 mm. Thk. PVC edge bands glued by hot melt glue applied by auto edge banding machine. Modesty panel : Made from 18mm both side prelaminated particle boards.All edges are covered by 0.8mm PVC edge bands glued by hot melt glue applied by auto edge banding machine. As directed by Engineer-in-charge .SSR I.No.51.33 Sr.No 1858 Page No.358 (Fourth Floor) |
| 594 | Furniture :- Conference Table @ 3600Lx1400Dx750HTProviding & Fixing of Main Table @ 3600Lx1400Dx750HT - made up of 18+18mm Thick MDF top with PVC Membrane finish and waterfall edge profile. Aluminium Anodizied finish beeding of 4mm thich is running all over the table top edge. Gable ends is Aerofoiled Shape with front edges in PVC Membrane finish and rest in Prelaminated MDF with batton structure. Gable ends should be hollow from inside for the provision of passing electrical and Data wiring. , MODESTY PANEL:- to be made of 18 mm thick Prelaminated particle board with PVC edge band Access Flap:- For Wire manager 2 Nos...SSR I.No.51.31 Sr.No.1856 Page No.357 (Fourth Floor) |
| 595 | Furniture :- Free Standing Table @ 1200Lx600Dx750HTProviding and fixing Table of Size 1200 x 600 x 750 mm. Top: made from 25 mm Prelaminated Particle board. All edges are covered by 2 mm. Thk. PVC edge bands glued by hot melt glue applied by auto edge banding machine. Legs : C Shape made from CRCA Sheet with Powder Coat finish. Modesty panel : Made from 18mm both side prelaminated particle boards.All edges are covered by 0.8mm PVC edge bands glued by hot melt glue applied by auto edge banding machine.KEYBOARD TRAY ( WITHOUT MOUSE TRAY ) :- Metal Powder Coated - Black Color, CPU TROLLEY :- Metal Powder Coated - Black Color, 3 DRAWER PEDESTAL UNIT having overall size 392L x 450D x 680Ht. mm. with central lock and key. Drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminated particle board, SSR.INo.51.28 Sr.No.1853 Page No.357 (First Floor) |
| 596 | Furniture :- Free Standing Table @ 1200Lx600Dx750HTProviding and fixing Table of Size 1200 x 600 x 750 mm. Top: made from 25 mm Prelaminated Particle board. All edges are covered by 2 mm. Thk. PVC edge bands glued by hot melt glue applied by auto edge banding machine. Legs : C Shape made from CRCA Sheet with Powder Coat finish. Modesty panel : Made from 18mm both side prelaminated particle boards.All edges are covered by 0.8mm PVC edge bands glued by hot melt glue applied by auto edge banding machine.KEYBOARD TRAY ( WITHOUT MOUSE TRAY ) :- Metal Powder Coated - Black Color, CPU TROLLEY :- Metal Powder Coated - Black Color, 3 DRAWER PEDESTAL UNIT having overall size 392L x 450D x 680Ht. mm. with central lock and key. Drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminated particle board, SSR.INo.51.28 Sr.No.1853 Page No.357 (Second Floor) |
| 597 | Furniture :- Free Standing Table @ 1200Lx600Dx750HTProviding and fixing Table of Size 1200 x 600 x 750 mm. Top: made from 25 mm Prelaminated Particle board. All edges are covered by 2 mm. Thk. PVC edge bands glued by hot melt glue applied by auto edge banding machine. Legs : C Shape made from CRCA Sheet with Powder Coat finish. Modesty panel : Made from 18mm both side prelaminated particle boards.All edges are covered by 0.8mm PVC edge bands glued by hot melt glue applied by auto edge banding machine.KEYBOARD TRAY ( WITHOUT MOUSE TRAY ) :- Metal Powder Coated - Black Color, CPU TROLLEY :- Metal Powder Coated - Black Color, 3 DRAWER PEDESTAL UNIT having overall size 392L x 450D x 680Ht. mm. with central lock and key. Drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminated particle board, SSR.INo.51.28 Sr.No.1853 Page No.357 (Third Floor) |
| 598 | Furniture :- Free Standing Table @ 1200Lx600Dx750HTProviding and fixing Table of Size 1200 x 600 x 750 mm. Top: made from 25 mm Prelaminated Particle board. All edges are covered by 2 mm. Thk. PVC edge bands glued by hot melt glue applied by auto edge banding machine. Legs : C Shape made from CRCA Sheet with Powder Coat finish. Modesty panel : Made from 18mm both side prelaminated particle boards.All edges are covered by 0.8mm PVC edge bands glued by hot melt glue applied by auto edge banding machine.KEYBOARD TRAY ( WITHOUT MOUSE TRAY ) :- Metal Powder Coated - Black Color, CPU TROLLEY :- Metal Powder Coated - Black Color, 3 DRAWER PEDESTAL UNIT having overall size 392L x 450D x 680Ht. mm. with central lock and key. Drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminated particle board, SSR.INo.51.28 Sr.No.1853 Page No.357 (Fourth Floor) |
| 599 | Furniture :- Free Standing Table @ 1500Lx600Dx750HTProviding and fixing Table of Size 1500 x 600 x 750 mm. Top: made from 25 mm Prelaminated Particle board. All edges are covered by 2 mm. Thk. PVC edge bands glued by hot melt glue applied by auto edge banding machine. Legs : C Shape made from CRCA Sheet with Powder Coat finish. Modesty panel : Made from 18mm both side prelaminated particle boards.All edges are covered by 0.8mm PVC edge bands glued by hot melt glue applied by auto edge banding machine.KEYBOARD TRAY ( WITHOUT MOUSE TRAY ) :- Metal Powder Coated - Black Color, CPU TROLLEY :- Metal Powder Coated - Black Color, 3 DRAWER PEDESTAL UNIThaving overall size 392L x 450D x 680Ht. mm. with central lock and key. Drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminated particle board, SSR.INo.51.26 Sr.No.1851 Page No.356 (First Floor) |
| 600 | Furniture :- Free Standing Table @ 1500Lx600Dx750HTProviding and fixing Table of Size 1500 x 600 x 750 mm. Top: made from 25 mm Prelaminated Particle board. All edges are covered by 2 mm. Thk. PVC edge bands glued by hot melt glue applied by auto edge banding machine. Legs : C Shape made from CRCA Sheet with Powder Coat finish. Modesty panel : Made from 18mm both side prelaminated particle boards.All edges are covered by 0.8mm PVC edge bands glued by hot melt glue applied by auto edge banding machine.KEYBOARD TRAY ( WITHOUT MOUSE TRAY ) :- Metal Powder Coated - Black Color, CPU TROLLEY :- Metal Powder Coated - Black Color, 3 DRAWER PEDESTAL UNIThaving overall size 392L x 450D x 680Ht. mm. with central lock and key. Drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminated particle board, SSR.INo.51.26 Sr.No.1851 Page No.356 (Second Floor) |
| 601 | Furniture :- Free Standing Table @ 1500Lx600Dx750HTProviding and fixing Table of Size 1500 x 600 x 750 mm. Top: made from 25 mm Prelaminated Particle board. All edges are covered by 2 mm. Thk. PVC edge bands glued by hot melt glue applied by auto edge banding machine. Legs : C Shape made from CRCA Sheet with Powder Coat finish. Modesty panel : Made from 18mm both side prelaminated particle boards.All edges are covered by 0.8mm PVC edge bands glued by hot melt glue applied by auto edge banding machine.KEYBOARD TRAY ( WITHOUT MOUSE TRAY ) :- Metal Powder Coated - Black Color, CPU TROLLEY :- Metal Powder Coated - Black Color, 3 DRAWER PEDESTAL UNIThaving overall size 392L x 450D x 680Ht. mm. with central lock and key. Drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminated particle board, SSR.INo.51.26 Sr.No.1851 Page No.356 (Third Floor) |
| 602 | Furniture :- Free Standing Table @ 1500Lx600Dx750HTProviding and fixing Table of Size 1500 x 600 x 750 mm. Top: made from 25 mm Prelaminated Particle board. All edges are covered by 2 mm. Thk. PVC edge bands glued by hot melt glue applied by auto edge banding machine. Legs : C Shape made from CRCA Sheet with Powder Coat finish. Modesty panel : Made from 18mm both side prelaminated particle boards.All edges are covered by 0.8mm PVC edge bands glued by hot melt glue applied by auto edge banding machine.KEYBOARD TRAY ( WITHOUT MOUSE TRAY ) :- Metal Powder Coated - Black Color, CPU TROLLEY :- Metal Powder Coated - Black Color, 3 DRAWER PEDESTAL UNIThaving overall size 392L x 450D x 680Ht. mm. with central lock and key. Drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminated particle board, SSR.INo.51.26 Sr.No.1851 Page No.356 (Fourth Floor) |
| 603 | Furniture :- Executive Table @ 2250Lx2100Dx750HT including Low Height Credestal @ 1200Lx450Dx650HT Providing & Fixing of Table @ 2250Lx2100Dx750HT TOP & GABLE END to be made of Membrane finish with soft water fall edges & curved panel & Decorated Anodized section MODESTY PANEL to be made of 18 mm thick Prelaminated particle board with PVC edge band. INCLUDING CREDESTAL @ 1200L X 450D X 650H :- To be made out of Membrane Finish ( 2 Openable Shutter & 3 Drawer Pedestal in between ) as per drawing... SSR.INo.51.24 Sr.No.1849 Page No.355 (First Floor) |
| 604 | Furniture :- Executive Table @ 2250Lx2100Dx750HT including Low Height Credestal @ 1200Lx450Dx650HT Providing & Fixing of Table @ 2250Lx2100Dx750HT TOP & GABLE END to be made of Membrane finish with soft water fall edges & curved panel & Decorated Anodized section MODESTY PANEL to be made of 18 mm thick Prelaminated particle board with PVC edge band. INCLUDING CREDESTAL @ 1200L X 450D X 650H :- To be made out of Membrane Finish ( 2 Openable Shutter & 3 Drawer Pedestal in between ) as per drawing... SSR.INo.51.24 Sr.No.1849 Page No.355 (Second Floor) |
| 605 | Furniture :- Executive Table @ 2250Lx2100Dx750HT including Low Height Credestal @ 1200Lx450Dx650HT Providing & Fixing of Table @ 2250Lx2100Dx750HT TOP & GABLE END to be made of Membrane finish with soft water fall edges & curved panel & Decorated Anodized section MODESTY PANEL to be made of 18 mm thick Prelaminated particle board with PVC edge band. INCLUDING CREDESTAL @ 1200L X 450D X 650H :- To be made out of Membrane Finish ( 2 Openable Shutter & 3 Drawer Pedestal in between ) as per drawing... SSR.INo.51.24 Sr.No.1849 Page No.355 (Third Floor) |
| 606 | Furniture :- Executive Table @ 2250Lx2100Dx750HT including Low Height Credestal @ 1200Lx450Dx650HT Providing & Fixing of Table @ 2250Lx2100Dx750HT TOP & GABLE END to be made of Membrane finish with soft water fall edges & curved panel & Decorated Anodized section MODESTY PANEL to be made of 18 mm thick Prelaminated particle board with PVC edge band. INCLUDING CREDESTAL @ 1200L X 450D X 650H :- To be made out of Membrane Finish ( 2 Openable Shutter & 3 Drawer Pedestal in between ) as per drawing... SSR.INo.51.24 Sr.No.1849 Page No.355 (Fourth Floor) |
| 607 | Furniture :- Executive\"sTable @ 1800Lx900Dx750HTProviding & Fixing of Table @ 1800Lx900Dx750HT - TOP & GABLE END to be made of Membrane finish with soft water fall edges & curved panel & Decorated Anodized section MODESTY PANEL to be made of 18 mm thick Prelaminated particle board with PVC edge band as per drawingSSR.INo.51.21 Sr.No.1846 Page No.355 (First Floor) |
| 608 | Furniture :- Executive\"sTable @ 1800Lx900Dx750HTProviding & Fixing of Table @ 1800Lx900Dx750HT - TOP & GABLE END to be made of Membrane finish with soft water fall edges & curved panel & Decorated Anodized section MODESTY PANEL to be made of 18 mm thick Prelaminated particle board with PVC edge band as per drawingSSR.INo.51.21 Sr.No.1846 Page No.355 (Second Floor) |
| 609 | Furniture :- Executive\"sTable @ 1800Lx900Dx750HTProviding & Fixing of Table @ 1800Lx900Dx750HT - TOP & GABLE END to be made of Membrane finish with soft water fall edges & curved panel & Decorated Anodized section MODESTY PANEL to be made of 18 mm thick Prelaminated particle board with PVC edge band as per drawingSSR.INo.51.21 Sr.No.1846 Page No.355 (Third Floor) |
| 610 | Furniture :- Executive\"sTable @ 1800Lx900Dx750HTProviding & Fixing of Table @ 1800Lx900Dx750HT - TOP & GABLE END to be made of Membrane finish with soft water fall edges & curved panel & Decorated Anodized section MODESTY PANEL to be made of 18 mm thick Prelaminated particle board with PVC edge band as per drawingSSR.INo.51.21 Sr.No.1846 Page No.355 (Fourth Floor) |
| 611 | Furniture :- Stool for Lab and Class-IVProviding and fixing 4 legged Lab stool, Legs made of 16 Guage 45 MM Outer dimension MS Pipe, Duly painted, With a 304 Grade Stainless steel 12 inch wide seat with a 1 inch collar, Height adjustment via a screw. as per design and drawing and instructions of Engineer in charge.SSR.INo.51.51 Sr.No.1876 Page No.365 (First Floor) |
| 612 | Furniture :- Stool for Lab and Class-IVProviding and fixing 4 legged Lab stool, Legs made of 16 Guage 45 MM Outer dimension MS Pipe, Duly painted, With a 304 Grade Stainless steel 12 inch wide seat with a 1 inch collar, Height adjustment via a screw. as per design and drawing and instructions of Engineer in charge.SSR.INo.51.51 Sr.No.1876 Page No.365 (Third Floor) |
| 613 | Furniture :- Providng and fixing in position anodised extruded aluminum partitions, partly glazed and partly laminated having frame made out of extruded tubular section of size 40 mm x 60 mm with 12 mm thick three layered flat pressed teak wood particle board bonded with BWP type exterior grade phenol formaldehyde synthetic resin conforming to IS 128231990, laminated on both sides,Novateakor equivalent and 5 mm thick selected quality plain/ float glass panels fixed with aluminum glass clips 12 mm x 12 mm and rubbercushioningbeadingtoglass partitions as per approved drawing etc. compete complete As directed by Engineer-incharge SSR I.No.39.72 Sr.No.1267 Page No.260 (First Floor ) |
| 614 | Furniture :- Providng and fixing in position anodised extruded aluminum partitions, partly glazed and partly laminated having frame made out of extruded tubular section of size 40 mm x 60 mm with 12 mm thick three layered flat pressed teak wood particle board bonded with BWP type exterior grade phenol formaldehyde synthetic resin conforming to IS 128231990, laminated on both sides,Novateakor equivalent and 5 mm thick selected quality plain/ float glass panels fixed with aluminum glass clips 12 mm x 12 mm and rubbercushioningbeadingtoglass partitions as per approved drawing etc. compete complete As directed by Engineer-incharge SSR I.No.39.72 Sr.No.1267 Page No.260 (Second Floor ) |
| 615 | Furniture :- Providng and fixing in position anodised extruded aluminum partitions, partly glazed and partly laminated having frame made out of extruded tubular section of size 40 mm x 60 mm with 12 mm thick three layered flat pressed teak wood particle board bonded with BWP type exterior grade phenol formaldehyde synthetic resin conforming to IS 128231990, laminated on both sides,Novateakor equivalent and 5 mm thick selected quality plain/ float glass panels fixed with aluminum glass clips 12 mm x 12 mm and rubbercushioningbeadingtoglass partitions as per approved drawing etc. compete complete As directed by Engineer-incharge SSR I.No.39.72 Sr.No.1267 Page No.260 (Third Floor ) |
| 616 | Furniture :- Providng and fixing in position anodised extruded aluminum partitions, partly glazed and partly laminated having frame made out of extruded tubular section of size 40 mm x 60 mm with 12 mm thick three layered flat pressed teak wood particle board bonded with BWP type exterior grade phenol formaldehyde synthetic resin conforming to IS 128231990, laminated on both sides,Novateakor equivalent and 5 mm thick selected quality plain/ float glass panels fixed with aluminum glass clips 12 mm x 12 mm and rubbercushioningbeadingtoglass partitions as per approved drawing etc. compete complete As directed by Engineer-incharge SSR I.No.39.72 Sr.No.1267 Page No.260 (Fourth Floor ) |
| 617 | Furniture :- Single Bed @ 2025LX 1000DX 650H Providing and fixing Single Bed of Size 2025Lx1000Dx650H with matress and pillow.n Understructure: - The legs are made of Square tube of size 25 x 25mm made out of MS with a thickness of 1.2 mm. The legs should have corner brackets welded to it at two levels. The corner brackets are made of 2mm thick CRCA having a L shaped structure to join the side panels and headboard to the leg. Three nos. of Horizontal stiffeners are provided at equal intervals. The stiffeners are made of Square tube of size 25 x 25mm made out of MS with a thickness of 1.2mm. The middle Horizontal Stiffener has a leg attached to it to transfer the load to the ground and add to the strength and stability of the complete structure. This leg is also made of Square tube of size 25 x 25mm made out of MS with a thickness of 1.2mm. All Metal components to undergo 7 tank treatment process and should be powder coated to the thickness of minimum 50 Microns DFT. Side Panel: - The side panels are made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The overall width of the side panel is 150mm. The side panels have 18mm thick prelam particle board Baton running for required length to add rigidity to the structure. Head Board :- The head board is made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The head board size to be considered as 1000 x 650mm. Foot Board :- The foot board is made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The head board size to be considered as 1000 x 450mm. Bed Base: - The Bed Base is made up of 12mm thick Prelam Particle Board with both side White laminate. SSR I.No.51.55 Sr.No.1880 Page No.366 (First Floor ) |
| 618 | Furniture :- Single Bed @ 2025LX 1000DX 650H Providing and fixing Single Bed of Size 2025Lx1000Dx650H with matress and pillow.n Understructure: - The legs are made of Square tube of size 25 x 25mm made out of MS with a thickness of 1.2 mm. The legs should have corner brackets welded to it at two levels. The corner brackets are made of 2mm thick CRCA having a L shaped structure to join the side panels and headboard to the leg. Three nos. of Horizontal stiffeners are provided at equal intervals. The stiffeners are made of Square tube of size 25 x 25mm made out of MS with a thickness of 1.2mm. The middle Horizontal Stiffener has a leg attached to it to transfer the load to the ground and add to the strength and stability of the complete structure. This leg is also made of Square tube of size 25 x 25mm made out of MS with a thickness of 1.2mm. All Metal components to undergo 7 tank treatment process and should be powder coated to the thickness of minimum 50 Microns DFT. Side Panel: - The side panels are made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The overall width of the side panel is 150mm. The side panels have 18mm thick prelam particle board Baton running for required length to add rigidity to the structure. Head Board :- The head board is made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The head board size to be considered as 1000 x 650mm. Foot Board :- The foot board is made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The head board size to be considered as 1000 x 450mm. Bed Base: - The Bed Base is made up of 12mm thick Prelam Particle Board with both side White laminate. SSR I.No.51.55 Sr.No.1880 Page No.366 (Second Floor ) |
| 619 | Furniture :- Single Bed @ 2025LX 1000DX 650H Providing and fixing Single Bed of Size 2025Lx1000Dx650H with matress and pillow.n Understructure: - The legs are made of Square tube of size 25 x 25mm made out of MS with a thickness of 1.2 mm. The legs should have corner brackets welded to it at two levels. The corner brackets are made of 2mm thick CRCA having a L shaped structure to join the side panels and headboard to the leg. Three nos. of Horizontal stiffeners are provided at equal intervals. The stiffeners are made of Square tube of size 25 x 25mm made out of MS with a thickness of 1.2mm. The middle Horizontal Stiffener has a leg attached to it to transfer the load to the ground and add to the strength and stability of the complete structure. This leg is also made of Square tube of size 25 x 25mm made out of MS with a thickness of 1.2mm. All Metal components to undergo 7 tank treatment process and should be powder coated to the thickness of minimum 50 Microns DFT. Side Panel: - The side panels are made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The overall width of the side panel is 150mm. The side panels have 18mm thick prelam particle board Baton running for required length to add rigidity to the structure. Head Board :- The head board is made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The head board size to be considered as 1000 x 650mm. Foot Board :- The foot board is made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The head board size to be considered as 1000 x 450mm. Bed Base: - The Bed Base is made up of 12mm thick Prelam Particle Board with both side White laminate. SSR I.No.51.55 Sr.No.1880 Page No.366 (Third Floor ) |
| 620 | Furniture :- Single Bed @ 2025LX 1000DX 650H Providing and fixing Single Bed of Size 2025Lx1000Dx650H with matress and pillow.n Understructure: - The legs are made of Square tube of size 25 x 25mm made out of MS with a thickness of 1.2 mm. The legs should have corner brackets welded to it at two levels. The corner brackets are made of 2mm thick CRCA having a L shaped structure to join the side panels and headboard to the leg. Three nos. of Horizontal stiffeners are provided at equal intervals. The stiffeners are made of Square tube of size 25 x 25mm made out of MS with a thickness of 1.2mm. The middle Horizontal Stiffener has a leg attached to it to transfer the load to the ground and add to the strength and stability of the complete structure. This leg is also made of Square tube of size 25 x 25mm made out of MS with a thickness of 1.2mm. All Metal components to undergo 7 tank treatment process and should be powder coated to the thickness of minimum 50 Microns DFT. Side Panel: - The side panels are made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The overall width of the side panel is 150mm. The side panels have 18mm thick prelam particle board Baton running for required length to add rigidity to the structure. Head Board :- The head board is made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The head board size to be considered as 1000 x 650mm. Foot Board :- The foot board is made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The head board size to be considered as 1000 x 450mm. Bed Base: - The Bed Base is made up of 12mm thick Prelam Particle Board with both side White laminate. SSR I.No.51.55 Sr.No.1880 Page No.366 (Fourth Floor ) |
| 621 | Furniture :- Bed Side Table @ 400LX 400DX 415H Providing and Fixing Bed Side Table of size 400LX 400DX 415H The bed side unit is made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The bed side table has one drawer and one shelf. The shelf is made of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding SSR I.No.51.58 Sr.No.1883 Page No.367 (Ground Floor ) |
| 622 | Furniture :- Bed Side Table @ 400LX 400DX 415H Providing and Fixing Bed Side Table of size 400LX 400DX 415H The bed side unit is made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The bed side table has one drawer and one shelf. The shelf is made of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding SSR I.No.51.58 Sr.No.1883 Page No.367 (First Floor ) |
| 623 | Furniture :- Bed Side Table @ 400LX 400DX 415H Providing and Fixing Bed Side Table of size 400LX 400DX 415H The bed side unit is made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The bed side table has one drawer and one shelf. The shelf is made of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding SSR I.No.51.58 Sr.No.1883 Page No.367 (Second Floor ) |
| 624 | Furniture :- Bed Side Table @ 400LX 400DX 415H Providing and Fixing Bed Side Table of size 400LX 400DX 415H The bed side unit is made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The bed side table has one drawer and one shelf. The shelf is made of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding SSR I.No.51.58 Sr.No.1883 Page No.367 (Third Floor ) |
| 625 | Furniture :- rear panel, central partition etc. Will act as an integral member of the Unit. SHELVES : Shelves made of 22SWG thick Prime Quality C.R.C.A. having 10 folds each will be provided each designed to carry a U.D.L. of 70 Kilograms. VERTICAL PANEL : Vertical panel consists of the front, Centre & rear panel shall be made out of 20SWG thick C.R.C.A. Prime quality Mild Steel & designed to take the load of shelves. DRIVE COVER PANEL : Made out of 22SWG thick C. R.C. A. prime quality Steel to cover the entire drive mechanism. CENTRE PARTITION : The Centre partition will comprise of a full C.R.C.A. prime quality Mild Steel 22SWG Sheet. LOCKING : System will be provided with individual rack locking as well as centralised locking arrangement on the last unit when all units are brought together, central lock when operated gets locked with the floor & does not allow access to the units. DRIVE MECHANISM : Driving Mechanism will be provided externally supported on special grade anti-friction bearing to have smooth & effortless movement. Entire mechanism or gear & sprockets shall be incorporated within the front panel provided in the front of the unit within an area of 1000mm x 200mm x 60mm. DRIVING WHEEL : Fully Powder Coated three pronged drive wheel for better torque & free movement of the rack over the guide rail. INDEXING ARRANGEMENT : Acrylic card holders provided on the front panel for easy identification & retrieval. FINAL FINISH : Powder Coating (8 tanks process with 70 microns). As directed byEngineer-in-charge.SSR I.No.51.45 Sr.No.1870 Page No.360(For First Floor) |
| 626 | Furniture :-Providing and fixing partitions made up of CCTW frame of size 75 mm x 50 mm at 60 cm c/c with 9 mm thick commercial ply and 4mm thick veneer on both sides with French polish etc. complete. SSR.INo.39.69 Sr.No.1264 page No.259 (For FIRST floor) |
| 627 | Furniture :- Providing and fixing partitions made up of CCTW frame of size 75 mm x 50 mm at 60 cm c/c with 9 mm thick commercial ply and 4mm thick veneer on both sides with French polish etc. complete. SSR.INo.39.69 Sr.No.1264 page No.259(For Seconfd FLOOR_) |
| 628 | Furniture :- Providing and fixing partitions made up of CCTW frame of size 75 mm x 50 mm at 60 cm c/c with 9 mm thick commercial ply and 4mm thick veneer on both sides with French polish etc. complete. SSR.INo.39.69 Sr.No.1264 page No.259 (For Third Floor) |
| 629 | Furniture :- Providing and fixing partitions made up of CCTW frame of size 75 mm x 50 mm at 60 cm c/c with 9 mm thick commercial ply and 4mm thick veneer on both sides with French polish etc. complete. SSR.INo.39.69 Sr.No.1264 page No.259 (For Fourth Floor) |
| 630 | Furniture :- Providing & Fixing Traditional Furniture Work Behind Hon.Judge Wall in 19mm BWR Plywood with 1.5mm thick approved textur laminate, making grooves, including hardware fitting, polishing etc. as per detailed drawing complete . (For First Floor) |
| 631 | Furniture :- Providing & Fixing Traditional Furniture Work Behind Hon.Judge Wall in 19mm BWR Plywood with 1.5mm thick approved textur laminate, making grooves, including hardware fitting, polishing etc. as per detailed drawing complete . (For Second Floor) |
| 632 | Furniture :- Providing & Fixing Traditional Furniture Work Behind Hon.Judge Wall in 19mm BWR Plywood with 1.5mm thick approved textur laminate, making grooves, including hardware fitting, polishing etc. as per detailed drawing complete . (For THIRD Floor) |
| 633 | Furniture :- Providing & Fixing Traditional Furniture Work Behind Hon.Judge Wall in 19mm BWR Plywood with 1.5mm thick approved textur laminate, making grooves, including hardware fitting, polishing etc. as per detailed drawing complete . (For Fourth Floor) |
| 634 | Furniture :-Providing & Fixing Dais Structure in 19mm BWR Plywood, making grooves, including hardwarefitting, polishing and 800 + GSM Carpet etc. as per detailed Drawing complete (For First Floor) |
| 635 | Furniture :- Providing & Fixing Dais Structure in 19mm BWR Plywood, making grooves, including hardwarefitting, polishing and 800 + GSM Carpet etc. as per detailed Drawing complete (For Second Floor) |
| 636 | Furniture :- Providing & Fixing Dais Structure in 19mm BWR Plywood, making grooves, including hardwarefitting, polishing and 800 + GSM Carpet etc. as per detailed Drawing complete (For THIRD Floor) |
| 637 | Furniture :- Providing & Fixing Dais Structure in 19mm BWR Plywood, making grooves, including hardwarefitting, polishing and 800 + GSM Carpet etc. as per detailed Drawing complete (For Fourth Floor) |
| 638 | Furniture :- Providing & Fixing Ramp for Witness Box in 19mm BWR Plywood with 1.5mm thick approved texture laminate, making grooves, including hardware fitting, polishing etc. as per detailed Drawing complete.(For First Floor) |
| 639 | Furniture :- Providing & Fixing Ramp for Witness Box in 19mm BWR Plywood with 1.5mm thick approved texture laminate, making grooves, including hardware fitting, polishing etc. as per detailed Drawing complete.(For Second Floor) |
| 640 | Furniture :- Providing & Fixing Ramp for Witness Box in 19mm BWR Plywood with 1.5mm thick approved texture laminate, making grooves, including hardware fitting, polishing etc. as per detailed Drawing complete.(For Third Floor) |
| 641 | Furniture :- Providing & Fixing Ramp for Witness Box in 19mm BWR Plywood with 1.5mm thick approved texture laminate, making grooves, including hardware fitting, polishing etc. as per detailed Drawing complete.(For Fourth Floor) |
| 642 | Furniture :- Providing & Fixing Footrest in 19mm BWR Plywood with 1.5mm thick approved texture laminate, making grooves, including hardware fitting, polishing etc. as per detailed Drawing complete.(For First Floor) |
| 643 | Furniture :- Providing & Fixing Footrest in 19mm BWR Plywood with 1.5mm thick approved texture laminate, making grooves, including hardware fitting, polishing etc. as per detailed Drawing complete.(For Second Floor) |
| 644 | Furniture :- Providing & Fixing Footrest in 19mm BWR Plywood with 1.5mm thick approved texture laminate, making grooves, including hardware fitting, polishing etc. as per detailed Drawing complete.(For Third Floor) |
| 645 | Furniture :- Providing & Fixing Footrest in 19mm BWR Plywood with 1.5mm thick approved texture laminate, making grooves, including hardware fitting, polishing etc. as per detailed Drawing complete.(For Fourth Floor) |
| 646 | Furniture :- Providing & Fixing Wooden Railing for Dais in 19mm BWR Plywood with 1.5mm thick approved textur laminate, making grooves, including hardware fitting, polishing etc. as per detailed drawing complete (For First Floor) |
| 647 | Furniture :- Providing & Fixing Wooden Railing for Dais in 19mm BWR Plywood with 1.5mm thick approved textur laminate, making grooves, including hardware fitting, polishing etc. as per detailed drawing complete (For Second Floor) |
| 648 | Furniture :- Providing & Fixing Wooden Railing for Dais in 19mm BWR Plywood with 1.5mm thick approved textur laminate, making grooves, including hardware fitting, polishing etc. as per detailed drawing complete (For Third Floor) |
| 649 | Furniture :- Providing & Fixing Wooden Railing for Dais in 19mm BWR Plywood with 1.5mm thick approved textur laminate, making grooves, including hardware fitting, polishing etc. as per detailed drawing complete (For Fourth Floor) |
| 650 | Furniture :- Providing & Fixing Wooden witness Box in 19mm BWR Plywood , making grooves, including hardware fitting , polishing etc. as per detailed drawing complete.(For First Floor) |
| 651 | Furniture :- Providing & Fixing Wooden witness Box in 19mm BWR Plywood , making grooves, including hardware fitting , polishing etc. as per detailed drawing complete.(For Second Floor) |
| 652 | Furniture :- Providing & Fixing Wooden witness Box in 19mm BWR Plywood , making grooves, including hardware fitting , polishing etc. as per detailed drawing complete.(For Third Floor) |
| 653 | Furniture :- Providing & Fixing Wooden witness Box in 19mm BWR Plywood , making grooves, including hardware fitting , polishing etc. as per detailed drawing complete.(For Fourth Floor) |
| 654 | Furniture :- Providing & Fixing Notepad in 19mm BWR PlywoodWith 1.5mm thick approved texture laminate, making grooves,imcluding hardware fitting , polishing etc. as per Detailed Drawing Complete.(For First Floor) |
| 655 | Furniture :- Providing & Fixing Notepad in 19mm BWR PlywoodWith 1.5mm thick approved texture laminate, making grooves,imcluding hardware fitting , polishing etc. as per Detailed Drawing Complete.(For Second Floor) |
| 656 | Furniture :- Providing & Fixing Notepad in 19mm BWR PlywoodWith 1.5mm thick approved texture laminate, making grooves,imcluding hardware fitting , polishing etc. as per Detailed Drawing Complete.(For Third Floor) |
| 657 | Furniture :- Providing & Fixing Notepad in 19mm BWR PlywoodWith 1.5mm thick approved texture laminate, making grooves,imcluding hardware fitting , polishing etc. as per Detailed Drawing Complete.(For Fourth Floor) |
| 658 | Furniture :- Providing & Fixing Table Top in 19mm BWR Plywood with 1.5mm thick approved texture laminate, making grooves, including hardware fitting, Teak wood Legs, polishing etc. as per Detailed Drawing Complete.Including Providing 6mm thick plain galss on table top(For First Floor) |
| 659 | Furniture :- Providing & Fixing Table Top in 19mm BWR Plywood with 1.5mm thick approved texture laminate, making grooves, including hardware fitting, Teak wood Legs, polishing etc. as per Detailed Drawing Complete.Including Providing 6mm thick plain galss on table top(For Second Floor) |
| 660 | Furniture :- Providing & Fixing Table Top in 19mm BWR Plywood with 1.5mm thick approved texture laminate, making grooves, including hardware fitting, Teak wood Legs, polishing etc. as per Detailed Drawing Complete.Including Providing 6mm thick plain galss on table top(For Third Floor) |
| 661 | Furniture :- Providing & Fixing Table Top in 19mm BWR Plywood with 1.5mm thick approved texture laminate, making grooves, including hardware fitting, Teak wood Legs, polishing etc. as per Detailed Drawing Complete.Including Providing 6mm thick plain galss on table top(For Fourth Floor) |
| 662 | Cattle\"s Trap :- Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer)etc.complete.Withfineaggregate(Crushed sand VSI Grade) Spec. No. Bd.F.11 Page 1 No. 304 and B.7, Page No. 38.SSR I.No.26.19, Sr.No.861, P.No.185 ( Ground Floor ) |
| 663 | Cattle\"s Trap :- Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete.. Spec. No. Bd.C.2 Page 1 Number 275 SSR I.No.23.01, Sr.No.816, P.No.173( Ground Floor ) |
| 664 | Cattle\"s Trap :- Providing internal cement plaster 20mm thick in Single coats in cement mortar 1:5 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete Spec. No. : Bd.L.4 Page 1 No. 368. SSR I.No.32.06, Sr.No.960, P.No.209( Ground Floor ) |
| 665 | C.D.Work-Providing selected hard murum filling including laying in layers of 15 to 20cmwithwatering and compacting etc. complete. Spec. No. CD.14 Page.Number 167. SSR I.No. 11.24, Sr.No.399, P.No.82(For Ground Floor) |
| 666 | C.D.Work-Providing and laying in situ / ready mix cement concrete of M-10 proportion with trap/granite/ quartzite/ gneiss metal in foundation including necessary form work, compactingand curing etc. complete. (with reversible drum type mixer with SCADA with fineagreegates of required specifications (Natural sand / VSI sand finely washed etc ) .Spec. No.CD-3 Page.Number 160. SSR I.No. 11.02, Sr.No.377, P.No.81 (For Ground Floor) |
| 667 | C.D.Work-Providing cast in situ / ready mix block of M10 cement concrete with circular or other shaped opening for waterway including necessary formwork, compaction, finishing and curing etc. complete. (with reversible drum type mixer/ concrete batch mix plant (pan mixer) with SCADA with fine agreegates of required specifications (Natural sand / VSI sand finely washed etc ), cement 4.05 bags/cumt)Spec. No.CD.8 Page.Number 163. SSR I.No. 11.22, Sr.No.398, P.No.82(For Ground Floor) |
| 668 | C.D.Work-Providing and casting in situ / ready mix PCC M15 grade of trap metal for coping to head walls / parapet including centering, form work, compaction and curing etc. complete. (with reversible drum type mixer/ concrete batch mix plant (pan mixer) with SCADA with fine agreegates of required specifications (Natural sand / VSI sand finely washed etc ) Spec. No.Bd-E-7. SSR I.No. 11.30, Sr.No.404, P.No.83 (For Ground Floor) |
| 669 | C.D.Work-Providing and laying cement concrete pipe of IS 458:2003 NP-3 class of 1200mm diameter in proper line, level and slopeetc. complete. Spec. No.CD.7 Page. Number 162. SSR I.No. 11.18, Sr.No.394, P.No.82 (For Ground Floor) |
| 670 | security room-Plain Cement Concrete-Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ granite/quartzite/gneissmetalforbedblocks,foundationblocksand suchotheritems including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Sepc. No. Bd.E.4 Page Number 289 and B7, Page Number38. SSR I.No. 24.08, Sr.No. 830, P.176(Ground Floor) |
| 671 | security room-Plain Cement Concrete-Providing and laying Cast in situ/Ready Mix cement concrete M-15 of trap/ granite/quartzite/gneiss metal for coping to plinth or parapet, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) With fine aggregate (Crushed sand VSI Grade) Spec No. : Bd.E. 3/ Page No.288/ I.S. 456 (2000).SSR I.No.24.16, Sr.No.835, P.No.177(Ground Floor) |
| 672 | security room-Plain Cement Concrete-Providing and laying in situ /Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering formwork, laying/pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)Spec. No.Bd.F.3 Page 1 No. 298 and B.7, Page No.38. SSR I.No.25.11, Sr.No.836 P.No.178(Ground Floor) |
| 673 | security room-Plain Cement Concrete-Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)Spec. No. : Bd.F.5 Page No. 300 and B.7, Page.No. 38.SSR I.No.25.31, Sr.No.841, P.No.179(Ground Floor) |
| 674 | security room-Plain Cement Concrete-Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Spec. No. :Bd.F.6 Page Number 300 and B.7, Page 1 Number38 Page.No. 38.SSR I.No.25.50, Sr.No.846, P.No.181(Ground Floor) |
| 675 | security room-Plain Cement Concrete-Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Spec No.Bd.F.8 Page No. 302 and B.7, Page1No.38. SSR I.No.25.70, Sr.No.851 P.No.182(Ground Floor) |
| 676 | security room-Plain Cement Concrete-Providing and laying Cast in situ/Ready Mixcement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete.Withfineaggregate (Crushed sand VSI Grade)Spec.No. Bd.F.9 Page 1 No. 303 and B.7, Page No.38.SSR I.No.26.05, Sr.No.856, P.No.184(Ground Floor) |
| 677 | security room-Plain Cement Concrete-Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting , curing , finishing and rougheningthem if special finish is to be provided and curing complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Spec. No. Bd.F.11 Page 1 No. 304 and B.7, Page No. 38.SSR I.No.26.17, Sr.No.860, P.No.185(Ground Floor) |
| 678 | security room-Structural Steel Work-Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete.. Spec. No. Bd.C.2 Page 1 Number 275 SSR I.No.23.01, Sr.No.816, P.No.173(Ground Floor) |
| 679 | security room-Brick Work-Providing fly ash brick masonry with conventional / I.S. type fly ash bricks in C.M. 1:6 in foundation and plinth including bailing out water manually striking joints, racking out joints watering and scaffolding etc. complete..Spec. No. As director by engineer in charge andBDG- 2 and 5. SSR I.No.27.12, Sr.No.899 P.No.198(Ground Floor) |
| 680 | security room-Water Proofing-Providing and applying water proofing treatment using acrylic polymer modified cement based water proofing coating with fibre glass mesh mixing at the rate of powder to liquid (2:1) by weight covering 9 to 10 Square Metre /Kilogram with two coat using approved chemicals for masonry and concrete surface by brush covering 7 years guarantee on Stamp Papers etc. complete. Spec. No. : As directed by Engineer in charge. SSR I.No.31.09, Sr.No.945, P.No.206(Ground Floor) |
| 681 | security room-Plastering & Pointing-Providing internal cement plaster 12mm thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete Spec. No. : Bd.L.4 Page 1 No. 368. SSR I.No.32.03, Sr.No.957, P.No.209(Ground Floor) |
| 682 | security room-Plastering & Pointing-Providing neeru finish to plastered surfaces in all positions including scaffolding and curing etc. complete.. Spec. No. : Bd. L.10, Page No.370. SSR I.No.32.15, Sr.No.966, P.No.210(Ground Floor) |
| 683 | security room-Plastering & Pointing-Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete. Spec No.: As directed by Engineer in charge. SSR I.No.32.26, Sr.No.977, P.No.210(Ground Floor) |
| 684 | security room-Plastering & Pointing-Providing groove to required size at specified location as directed by Engineer, at junction of brick masonry wall and R.C.C beams or Column, at junction of composite masonry, including scaffolding, finishing, curing etc. complete. Spec. No. As directed by Engineer in charge. SSR I.No.32.37, Sr.No.987, P.No.212(Ground Floor) |
| 685 | security room-Paving, Flooring & Dado-Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints,curingandclearing etc. complete. Spec. No. Bd.M.12 Page No. 385. SSR I.No.33.40, Sr.No.1027 P.No.217(Ground Floor) |
| 686 | security room-Paving, Flooring & Dado-Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete Spec. No. Bd.M.12 Page 1 No. 385. SSR I.No.33.41, Sr.No.1028 P.No.217(Ground Floor) |
| 687 | security room-Paving, Flooring & Dado-Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling jointswithneatcement slurry curing polishing and cleaningetc. complete.. Spec No.:Bd. M.22 B/Page Number 390. SSR I.No.33.35, Sr.No.1022, P(Ground Floor).216 |
| 688 | security room-Paving, Flooring & Dado-Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing,etc. complete..Spec. No. As directed by Engineer-In- Charge. SSR I.No.33.68, Sr.No.1052 P.No.220(Ground Floor) |
| 689 | security room-Oil Painting-Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete.. Spec. No. : As directed by Engineer in charge. SSR I.No.35.21, Sr.No.1090 P.No.225(Ground Floor) |
| 690 | security room-Oil Painting-Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces. (excluding the primer coat.) etc. complete.Spec. No. : Bd.P.5 Page No. 413. SSR I.No.36.11, Sr.No.1106 P.No.227(Ground Floor) |
| 691 | security room-Oil Painting-Providing and fixing 34 mm thick moulded door shutter consisting of solid core single leaf flush door of 30 mm thickness lipped with 15 mm ( 5mm x 3) thick x 30 mm width on one style and top rail and 10 mm (5mm x 2) thick x 30 mm width on other style and bottom rails. The inner panels laminated with 2 mm thick termite proof, water proof and fire resistant moulded PVC sheet with 2,4,6 design in different plain and /or prelim colours on one side after routing the moulded design on flush doors and 2 mm plain and /or pre lam PVC on other side using rubber adhesive on flush door and solvent cement adhesive on the PVC lipping etc. as per direction of Engineer in charge and manufacturersspecificationanddrawingetc. complete.. Spec. Nos. BD-T-34 Page Nos. 499. SSR I.Nos.39.48, Sr.Nos.1241 P.Nos.256(Ground Floor) |
| 692 | security room-Oil Painting-Providing and fixing in position (as per 1868 / 1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 Kilogram/One Running Metre. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 Kilogram/One Running Metre.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 Kilogram/Running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/One Running Metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/Running metre. and handle and top section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete. With powder coating without box. Spec. No. : As directed by Engineer in charge.SSR I.No.39.44, Sr.No.1237, P.No.254(Ground Floor) |
| 693 | security room-Iron Work-Providing and fixing mild steel grill work for windows, ventilators, etc. 15 Kilogram/ One Square Metre as per drawing including fixtures necessary welding and painting withonecoatof anticorrosive paint and two coats of oil painting complete.Spec. No. : Bd.U. 1 Page No. 537. SSR I.No.40.02, Sr.No.1292 P.No.264(Ground Floor) |
| 694 | security room-Water Supply & Sanitary Fittings-Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and One Number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete.Spec No. As directed by Engineer Incharge. SSR I.No.42.87, Sr.No.1458, P.No.283(Ground Floor) |
| 695 | security room-Miscellaneous-Providing and fixing 90 cm x 60 cm Granite plate engraving 10 cm. height letter,figures including painting the lefters/figures with approved colour and shade complet Spec. No. Bd.W.7 Page No.586. SSR I.No.44.12, Sr.No.1527, P.No.294(Ground Floor) |
| 696 | security room-Miscellaneous-Providing and fixing board displaying information, such as \"Name of work, Tender cost, Name of Contractor, Work completion and liability period etc\", having rectangular shape of 1.20m x 0.90m size made out 18 gauge (1.25mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border / messages / symbols etc. with approved colour shade paint complete, on M.S.angle of size 35 x 35 x 3 mm frame with properly cross braced M.S. angles of size 35mmx35mmx3mm duly painted including Two M.S. angle iron posts of size 65 mm x 65 mm x 6 mm, 3.65 m long painted with alternate black and white bands of 25 cm width including all fixtures etc.and fixing the boards in 1:4:8 concrete block of size 60 cm x 60 cm x 75 cm including, excavation, refilling, transportation, and labour etc complete. Spec. No. As directed by Engineer in Charge Spec. No. MORTH 801.SSR I.No.6.36, Sr.No.284 P.No.60(Ground Floor) |
| 697 | For Gardening & Landscapping - Excavation for planting lawn/ shrub/ flower bed/ hedges/ edges/ canna bed inearth, soil of all types, soft murum, including removing the excavated materialup to a distance of 50 mtrs. for a depth of 30 cms. (As per P&G DSR 2022-23 Items of garden work,Sr No.3) (flowering beds) |
| 698 | For Gardening & Landscapping - Supplying on site fresh Garden soil (i. e. 3 part soil ) (free from stones rubbish like dried grass roots, other such materials) for excavation area of depth of 30 cms ( consolidated thickness). I.No. 36a, Page No.15 (flowering beds) |
| 699 | For Gardening & Landscapping - Supplying on site well decomposed Farm Yard Manure (i. e. 1 part FYM) for excavation area of depth of 30 cms ( consolidatedthickness). DSR I.No. 36b, Page No.15(flowering beds) |
| 700 | For Gardening & Landscapping - Providing on site required variety of Tube rose (free from weeds /diesease etc.) Cynadon/ paspalum/ selection for 1 sqm. area dibbling distance 5 cms. Apart c/c. DSR I.No. 9, Page No.24(flowering beds) |
| 701 | For Gardening & Landscapping - Filling fresh garden soil / silt & manure in excavated area of depth 30cms. (1/10 of unskilled labour) (As per P&G DSR 2022-23 Items of garden work,Sr No.13) (flowering beds) |
| 702 | For Gardening & Landscapping - Mixing garden soil/silt & manure thoroughly well, watering previous night. Planting reqired plant species, lawn grass as directed etc. complete for required depth 5 to 30 cms. for planting lawn/ shrub/ flower bed/ hedges/ edges/ canna bed/ ground cover. (1/10 of semiskilled labour)(As per P&G DSR 2022-23 Items of garden work,Sr No.23) (flowering beds) |
| 703 | For Gardening & Landscapping - Maintainance of Newly planted rose plant For First 30 days Only (As per P&G DSR 2022-23 Items of garden work,Sr No.32) (flowering beds) |
| 704 | For Gardening & Landscapping - Excavation for planting lawn/ shrub/ flower bed/ hedges/ edges/ canna bed in earth, soil of all types, soft murum, including removing the excavated material up to a distance of 50 mtrs. for a depth of 20 cms. (As per P&G DSR 2022-23 Items of garden work,Sr No.5) (instant lawns) |
| 705 | For Gardening & Landscapping - Supplying on site fresh Garden soil (free from stones rubbish like dried grass roots, other such materials) for excavation area of depth of 20 cms.( consolidated thickness).(As per P&G DSR 2022-23 Items of garden work,Sr No.38a)(instant lawns) |
| 706 | For Gardening & Landscapping - Supplying on site well decomposed Farm Yard Manure for excavation area of depth of 20 cms. (consolidated thickness).(As per P&G DSR 2022-23 Items of garden work,Sr No.38b) |
| 707 | For Gardening & Landscapping - Providing on site well established (free from weeds /disease etc.) ready to fix lawn turf in slabs/ rolls of required variety as directed. (As per P&G DSR 2022- 23 Items of garden work,Sr No.47) |
| 708 | For Gardening & Landscapping - Filling fresh garden soil / silt & manure in excavated area of depth 20cms. (As per P&G DSR 2022-23 Items of garden work,Sr No.15) (instant lawns) |
| 709 | For Gardening & Landscapping - Mixing garden soil/silt & manure thoroughly well, watering previous night. Planting required plant species; lawn grass as directed etc. complete for required depth 20 cms. for planting lawn/ shrub/ flower bed/ hedges/ edges/ canna bed/ ground cover. (1/10 of semiskilled labour) (As per P&G DSR 2022- 23 Items of garden work,Sr No.23) (instant lawns) |
| 710 | For Gardening & Landscapping - Maintenance of Newly Developed lawn (Instant Lawn) Area. For First 30 days Only (As per P&G DSR 2022-23 Items of garden work,Sr No.29) (instant lawns) |
| 711 | Supplying and erecting HMS PVC conduit FRLS grade 20 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 712 | Supplying and laying HMS PVC conduit FRLS grade 20 mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 713 | Supplying and erectingHMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 714 | Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 715 | Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 716 | Supplying and laying HMS PVC conduitFRLS grade 32mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 717 | Supplying and erecting mains with 2x1.5 sq.mm FRLSHcopperPVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 718 | Supplying and erecting mains with 1x1.5 sq.mm FRLSHcopperPVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 719 | Supplying and erecting mains with 2x2.5 sq.mmFRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 720 | Supplying and erecting mains with 1x2.5 sq.mmFRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 721 | Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 722 | Supplying and erecting mains with 1x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 723 | Supplying and erecting mains with 2x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 724 | Supplying and erecting mains with 1x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 725 | Supplying and erecting mains with 4x10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 726 | Supplying and erecting mains with 1x10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 727 | Supplying and erectingmodular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. |
| 728 | Supplying and erectingmodular type switch 16Aduly erected on provided plate and box with wiring connections complete. |
| 729 | Supplying and erectingmodular type 3 pin 6Amultisocket with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 730 | Supplying and erectingmodular type 3 pin 6 / 16Amultisocket with safety shutter,duly erected on provided plate and box with wiring connections complete. |
| 731 | Supplying and erectingmodular type computer Jack RJ45 with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 732 | Supplying and erectingmodular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete. |
| 733 | Supplying and erecting unbreakable concealed typemodular switch box with double mounting plate for 1 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 734 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 735 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 736 | Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and requiredaccessories as per specification No: WG-PW/CW |
| 737 | Point wiring for ceiling fan concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and requiredaccessories as per specification No: WG-PW/CW |
| 738 | Point wiring for light/bellhybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls)in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/HW |
| 739 | Point wiring for ceiling fan (Surface type under false ceiling and concealed type for drops & switch boards on walls)in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/HW |
| 740 | Wiring for plug on board withSwitch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WG-PW/CW |
| 741 | Supplying and erecting 20m HDMI cord low voltage grademinimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete. |
| 742 | Supplying and installingcat-6 cable suitable for networking as per specification no. WG-COC/NC |
| 743 | Supplying and erecting LSZH armoured multimode optical fibre cable with 6 fibres, core dia 50/125 µm (OM3), suitable upto 10 GBPS, ethernet distance at 850 nm of wavelength, on wall/ceiling or laid in provided pipe/trench as per specification no. WG-COC/OFC LSZH |
| 744 | Supplying and installing armoured single mode optical fibre cable with6 fiber, core dia 50/125μm (OS1/OS2) 10/40 GBPS speed in provided underground HDPE pipe complete. |
| 745 | Supplying and fixing 1 m length, UTP patch cord of enhanced Cat 6 type with 4-connector channel, performance test report as per ANSI/TIA-568.2-Din position as per specification No. WG-COC/PC |
| 746 | Supplying, fixing, and configuring 24 ports with 4 (SFP+) port, ethernet managed switch with web view/CLI, 6KV surge protection on ethernet port and console port for management in provided rack as per specification no. WG-NWC/GBS |
| 747 | Supplying, fixing, and configuring broadband ADSL router with all accessories, on provided rack as per specification No. WG-NWC/ADSL |
| 748 | Supplying and fixing 9U wall mount rack (Dimension-DxWxH – 500x600x500 mm) as per specification No. WG-NAS/RAK |
| 749 | Supplying and erectingLEDPanel Light(600mm X 600mm) Max. 35 Whaving CRCA powder coated housing,polystyrene diffuser havingsystem lumens output of Min 4200 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%,THD<10%, p.f. >0.95, operating range of120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50including driver,having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. |
| 750 | Supplying and erectingbulk head LED fittingmax. 10Wwith high transitivity diffuser withsystem lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg.,THD<10%,p.f. >0.95, operating range of140-260V, in built surge protection of 2.5 kV, Life class of50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty. |
| 751 | Supplying and erecting anodized aluminium corridor / passage / mirror light LED fitting (2 feet) Max. 12Wwith high transitivity diffuser with min. system lumens output of 1200 lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%,THD<10%,p.f. >0.95, operating range of200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver with end caps on provided PVC Block / wooden board with 3 years warranty. |
| 752 | Supplying and erecting CRCA powder coated corridor/passage light LED fitting (4 feet) Max. 17Wwith high transitivity diffuser withsystem lumens output of Min. 2000 lumens , min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., Ripple<5%, THD<10%,p.f. >0.95, operating range of120-270V, surge protection of 4 kV, Life class of50,000 Hrs. at L70B50, includingdriver, with end caps on provided PVC Block / wooden board with 3 years warranty. |
| 753 | Supplying and erecting ding dong / electronic musical type call bell with heavy duty coilsuitable to operate on 230V A.C. supply erected on polished double wooden block/sunmica block of suitable size. |
| 754 | Supplying and erecting integrated LED street light fitting 40 to 50W IP65 & IK08 class having single piece pressure die-cast aluminium housing,havingsystem lumens output of Min. 4400 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification NoFG-ODF/FLS2. |
| 755 | Supplying and erecting integrated LED flood light fitting Max. 100W IP65 & IK07 class having pressure die-cast aluminium housing,having system lumens output of Min. 12000 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50,including driver with U shaped bracket with 3 Years warranty as per specification NoFG-ODF/FLS2. |
| 756 | Supplying and erecting street light Wall bracket made from 25 mm. dia ‘ G.I. pipe 1.2 m. in total length complete as per specification no. FG-BKT/WB |
| 757 | Supplying and erecting exhaust fan medium duty 230 V A.C. 50 cycles 225 mm. 1400 RPM with condenser complete erected in position with necessary materials. Fan motor with moisture proof treatment and ‘E’ class insulation. |
| 758 | Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of28W having service ratio (CMM/W) of Min. 8 , PF>0.9, THD<10% with IR remote control/compatible speed regulator, Temperature Rise of Max. 40 deg. C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF (Without Remote) |
| 759 | Supplying and erecting fan hook box of 10 mm M.S. round bar bounded to the R.C.C. bars upto 50 mm length each side and pierced through a 16 S.W.G. thick aluminium/M.S. Bowl 100 mm dia. or equivalent square size and having depth upto 75 mm complete erected with duly painted by one coat of red oxide paint and two coats of paint erected in position and without any leakage of slurry of cement concrete on either side of the box and positioned to the bottom level of the slab. |
| 760 | Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire. |
| 761 | Supplying, erecting, testing and commissioning self contained water cooler 230/250V 50Hz nominal cooling capacity of 80 litres per hour and storage capacity 120 litres with partially stainless steel body as per specification no. AP-WCR/WC |
| 762 | Supplying and erecting ultra violet water purifier with softener for safe drinking water consisting of UV germicidal tube of 8W capacity, choke made of copper wire, two indicator lamps, dual function cartridge with output of purified water 1 litre/min with activated carbon filter and softener operating on 230V, single phase A.C. supply with UV fail & filter change indication system. |
| 763 | Supplying, erecting, testingandcommissioning of 10kVA capacity onlinepure sine wave with backup time of 1 hrs. PWM & IGBT based UPS with 0.9 to unity output pf, 3 phase input & 1 phase output complete with all protectionsas per specification no. AP-UPS |
| 764 | Supplying and erecting 12V/42Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete |
| 765 | Supplying &erecting four poleON LOAD changeover switch, 415V, 315-320A, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, operational current category AC23A complying to IS/IEC 60947-3 Part-1/3. |
| 766 | Supplying and erecting switch disconnector fuse (SDF) 415V, 300-320A, with enclosure, four pole and neutral link AC23 A rated with terminal shrouds on both sides and phase barriers along with telescopic shaft for depth adjustments and door interlock and padlock complying to IS/IEC 60947-3 Part-1/3HRC - DIN type fuse switch, insulation voltage 1000 V,with rotary handle for ON / OFF operation (without HRC fuse) |
| 767 | Supplying, erecting & marking SPMCB 6A to 32A, C-serieswith rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 768 | Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 769 | Supplying, erecting & marking TPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 770 | Supplying&erecting triplepole and neutral distribution board (TPNDB),SPMCB of 4 ways/phase(12 poles), with door,1.2mm thickness, surface/flush mounted, IP 43 protection on iron/GIframe (horizontal busbar type) as per specification no. SW-SWR/MCBDB |
| 771 | Supplying&erectingtriplepole and neutral distribution board (TPNDB), SP/TP MCBs total 4 ways /12 Poles, with door, 1.2mm thickness surface/flushmounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB(For Distribution 8, 11 Nos For Power Dist. UPS) |
| 772 | Supplyingand erecting single pole and neutral distributionboard (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB |
| 773 | Providing & erecting 3 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact.MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB |
| 774 | Providing & erecting 3 Pole MCCB, 415V, 200A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB |
| 775 | Providing & erecting 3 Pole MCCB 415V, 400A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu),adjustablethermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure /panel as per specification no. SW-SWR/MCCB |
| 776 | Supplying, fixing and commissioning 4 poleRCBO 6/10/16/20/25A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indications per specification no SW-RCCB/RCBO |
| 777 | Supplying, fixing and commissioning 4 pole RCBO 32/40A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection,with 30/100/300 mA sensitivity and short circuit and earth leakage trip indicationas per specification no SW-RCCB/RCBO |
| 778 | Providing & erecting floor/wall mounting, MCCB panel board, with door, suitable for four pole incoming 250A, 6 ways four pole outgoing, up to 100 A MCCBs on iron frame, as per specification noSW-SWR/MCCBPB. (Excluding MCCBs) |
| 779 | Providing & erecting floor/wall mounting, MCCB panel board, with door, suitable for four pole incoming 400A, 12 ways four pole outgoing, up to 100 A MCCBs on iron frame, as per specification no. SW-SWR/MCCBPB. (Excluding MCCBs) |
| 780 | Providing & erecting incoming and outgoing cable alleys suitable for MCCB panel board with door, 250A incoming and 6 way outgoing or 400A incoming and 4 way outgoing made from CRCA sheet 1.6 mm thick duly powder coated and having vertical insulated partition for shielding between the shared face of cableway andDB. |
| 781 | Providing & erecting incoming and outgoing cable alleys suitable for MCCB panel board with door, 400A incoming and 12 way outgoing made from CRCA sheet 1.6 mm thick duly powder coated and having vertical insulated partition for shielding between the shared face of cableway and DB. |
| 782 | Supplying & erecting HRC fuse cartridge 415V, 300A |
| 783 | Supplying and erecting metal work in CRCA sheet including Iron work for supportswith fabrication ofboxes,panelboards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment andduly powder coated or paintedwith one coat of red lead paint and 2 coats of enamel paint complete. |
| 784 | Supplyinganderectingiron work, sheet metal work consisting of CRCAsheets, varioussectionsofiron,plates, chequeredplates,rods,bars,MSpipes,etc. forpanel board or any other purpose with bending, cutting, drilling and welding completeerectedatthepositionwith necessarymaterialsdulypaintedwith one coat of red oxide and two coats of enamelpaint to match the switchgears or as per directions by the authority.(Vertical Cabel Supports) |
| 785 | Supplying, erecting & terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core10sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL |
| 786 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core16sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL |
| 787 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 95sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL |
| 788 | Supplying andlaying (including excavation of suitable width & depth up to 90 cm) 50 mmoutside dia. double wall corrugatedpipes(DWC) ofHDPE for enclosing cable below ground/road surface, to required depth complete.(For Fiber Optic Cable) |
| 789 | Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 100 mm height comprising all required standard accessories. |
| 790 | Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results asper specification no. EA-EP |
| 791 | Providingpipetype earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rodcomplete with all materials testing and recording the results as per specification no. EA-EP |
| 792 | Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete. |
| 793 | Supplying & erectingconventionalspike typeair termination suitable to carry lightning stroke made up of heavy gauge40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipeerected on provided foundation complete. |
| 794 | Providing printed instruction chart for treating persons suffering from electric shock, printedinEnglish & Marathi and duly laminated complete. |
| 795 | Supplying standardfirst aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use, scissors, anti-septic solution, etc. (All above contents shall be of standard makes) |
| 796 | Supplying and fixingPVC synthetic elastomerelectrically insulating matwith class A insulation conforming to IS: 15652 – 2006having 2 mm thickness up to 3.3 kV |
| 797 | Supplying,erecting, testing and commissioning of 2 core shielded cable complete asper specification no.FF-PA/MCC (For PA) |
| 798 | Supplying, erecting, testing and commissioning of 0.75 sq. mm speaker wire complete. |
| 799 | Supply and erection with all accessories of Conference Chairman unit, Built in Microphone, Two Headphone Socket, Built-in volume control for headphones, 1 x 2.7 m (106.3 in) cable terminated with a 8-pin male connector for loop-through connection to other. 1 x 8-pin circular female connector for loop-through connection to other delegate or chairman units. 2 x 3.5 mm (0.14 in) stereo headphone sockets. Make - Bosch |
| 800 | Supply and erection with all accessories of Conference Delegate unit, Built in Microphone, Two Headphone Socket, Built-in volume control for headphones, 1 x 2.7 m (106.3 in) cable terminated with a 8-pin male connector for loop-through connection to other. 1 x 8-pin circular female connector for loop-through connection to other delegate or chairman units. 2 x 3.5 mm (0.14 in) stereo headphone sockets. Make- Bosch |
| 801 | Control unit with recorder and amplifier, Max Output Power 45 W, Frequency Response 80 Hz to 18 kHz, Loudspeaker Output 1 x |
| 802 | 12W Bi-Directional Cabinet Speaker, Effective frequency range ( -10 db ) 200 Hz – 15000 Hz, High Sound Pressure Level, In built 100V line matching transformer. Make- Bosch, LBD 3905 |
| 803 | 43\" 4K, 3840 x 2160, LED TV (350 nit Brightness,8 ms Response Time, HDMI INx2, DVI INx1, IR IN, USBx2, Audio In, Audio Out, RS232, RJ45 In, WIFI, BT). Make- Samsung, QB 43\" |
| 804 | Supplying, Installing, testing and commissioning ofDual channel UHF wireless microphone & receiver, including 2 handheld dynamic transmitters with operating range of minimum 30 mtr distance in line of sight between transmitter & receiver and with 2 x 1.5V batteriesof suitable size and and Current consupmtion <150mA, RF power output 10mW or higher suitable for frequency stability +/-0.005%, frequency response 50-15000Hz, channel frequency display & receiver with 220V-240V AC 50Hz AC Adaptor, distortion -/< 1% S/N ratio 100 dB suitable for same frequency as transmitterhaving controls like ON/OFF Switch, Volume control for both channels, LED indicators for RF & Audio Signal, channel frequency displays & operates on 12V DC through an AC adaptor complete as per specification no. PA-DPA-UHF |
| 805 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core95sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL |
| 806 | Supplying, erecting & terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core10sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL |
| 807 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core16sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL |
| 808 | Supplying, erecting & terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core35sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL |
| 809 | Providing & erecting hot dipped galvanised ladder type cable traymanufactured from 16 SWG (1.6 mm thick) GI sheet of 200 mm width & 100 mm height comprising all required standard accessories. |
| 810 | Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results asper specification no. EA-EP |
| 811 | Providingpipetype earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rodcomplete with all materials testing and recording the results as per specification no. EA-EP |
| 812 | Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete. |
| 813 | Supplying, installation, testing and commissioning of main fire pump (MFP / EP) suitable for water discharge of 1800 to 2280 LPM at 80 to 60 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 37kW or of suitable kW capacity for manual/automatic operation and consisting of following :(a) Horizontal type, single stage, centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520.(b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-\"F\" insulation, conforming to IS-325.(c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Erected on provided suitable size cement concretefoundation duly plastered with anti vibration pads with perfect aligning, properlevelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, asper specification no. FF-MFP/SSC/EP (Main Hydrant+Sprinkler+Standby) |
| 814 | Supplying, installation, testing and commissioning of jockey fire pump (JP)suitable for water discharge of 180 to 240 LPM at 110 to 90 m head driven by electric motor415 volts, 3 phase 50 Hz, AC supply of 11 kW or of suitable kW capacity for manual/automatic operation and consisting of following :(a) Horizontal/vertical type, multi stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520.(b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-\"F\" insulation, conforming to IS-325.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Erected on provided suitable size cement concretefoundation duly plastered with anti vibration pads with perfect aligning, properlevelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, asper specification no. FF-MFP/JP |
| 815 | Supplying, installation, testing and commissioning ofbooster fire pump [BP] suitable for water discharge of 450 LPM at 35 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 5.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following :(a) Horizontal/vertical type, single/multi stage, centrifugal casing pump of cast iron body & bronze/CI impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520.(b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operationwith IP 55 protection for enclosure, horizontal foot mounted type with Class-\"F\" insulation, conforming to IS-325.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Erected on provided suitable size cement concretefoundation duly plastered with anti vibration pads with perfect aligning, properlevellingcomplete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/BP |
| 816 | Supplying, installation, testing and commissioning ofmain fire pump (MFP/DP) suitable for water discharge of 2280 to 2850 LPM at 90 to 60 m head driven by 76 HP or suitable HP capacity diesel engine at required working speedsuitable for manual/automatic operation and consisting of following :(a) Horizontal type, single stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520.(b) Water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12/24 volts DC electric starting equipment with battery of required AH capacity with necessary charger suitable to work on 230v, 50Hz AC supply, diesel tank of minimum 150ltr capacity with first filling of diesel up to 100% level with necessary piping with valves up to engine , exhaust pipe extended up to 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications etc. as required.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Erected on provided suitable size cement concretefoundation duly plastered with anti vibration pads with perfect aligning, properlevelling complete pump set with engine assembly and accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/DP |
| 817 | Supplying, erecting, testing & commissioning offire pump control panel (FCP) of cubical construction, floor mounted type, fabricated from minimum 2 mm thick CRCA sheet, compartmentalised with hinged lockable doors, with enclosure protection class IP54, duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003), cable alley, interconnection with suitable size solid copper busbar strip of adequate size for all power connections having switchgears and accessories, mountings and internal wiring with adequate size copper conductor cable, earth terminals, numbering etc. complete in all respect, suitable for satisfactory operation of main fire pump and jockey (pressurisation) pumps (1working+1standby) with necessary accessories, wiring & cabling along with allied accessorieswith following incoming and outgoings, suitable for automatic & manual operation on 415V, 3 phase, 50Hz ac supply as per specificationsthe capacity of electric motor driven pump are as followsa. Main fire pump(MFP) having capacity of 22kW 1no (1 working)b. Jockey pump(JP) capacity of suitable capacity 2 nos(1 working +1 standby, alternate run per start in auto mode) comprises of the following features & switchgears:1. Main incomer FP SFU having rotary handle with HRC fuses of suitable rating.2. Electrolytic grade copper strips for busbar of suitable sizes for main incomer and branches to motor SFU\"s, starters & outgoing terminals with necessary accessories like stainless steel nut bolts with spring washers for connections, mounted on required no of epoxy or porcelain support insulators of suitable ratings etc. 3. Individual pump TPN SFU having rotary handlewith HRC fuses of suitable rating.4. Digital voltmeter & ammeter & RYB indicating lamps & push buttons & SPP, O/L & phase reversal protection with emergency stop switch.5. TPN SPD 100kA Type 1 +2 tested.6. Required pressure transducer with pressure indication on panel with cabling required for monitoring & automatic operation of fire pumps.7. System controller to control operation of main electric fire pump, jockey (pressurization) pumps in sequence with interlocking for operation of pumps as per specification with automatic/manual operation with selector switch & alternate run of standby Pumps consisting of relays, timers. sensors, annunciation window for fault indication, complete as per specification. 8.Suitable capacity electric motor starters for all individual pumps with necessary push buttons & indications.9. Siren of required capacity to be activated when main pump starts & allied accessories as per requirements of local CFO or as directed by engineer in charge.10. Danger board as per IS. 11. Spare HRC fuses minimum 2nos of each individual rating with required bakelite fuse holder for main & jockey fire pumps MFP=(1working), JP = (1working+1standby, alternate run per start in auto mode) complete panel, asper specification no. FF-MFP/ECPAdd Ons:-A-2)For main electric motor driven fire hydrant system pump of 37kW capacity & relevant capacity jockey pump add Rs 26217B-3)For main electric motor driven fire sprinkler system pump of 37kW capacity (1Working) & relevant capacity jockey pumps (1working+1standby, alternate run per start in auto mode,add Rs 161675C-3)For standby main electric driven fire hydrant/sprinkler system pump of 37kW capacity, add Rs 33616 D)For addition of standby main diesel engine driven fire pump (1 standby), add as follows in the basic cost of Item no 13-5-1 towards required 12/24 v battery charger and diesel engine starter along with necessary accessories, indicators etc. with necessary interlocking and updation of control logic with interlocking for operation of pumps MFP for main (1working+1standby mode)& jockey fire pumps (1working+1standby, alternate run per start in auto mode) , add Rs 68381/-The control for diesel engine comprises ofautomatic/manual selector switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode indicating lamp for high/ low Lub. oil pressure, high water temp and engine on indication battery charger suitable for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC voltmeter, and 0-20 A DC ammeter with all standard relays and accessories required for automatic operation of diesel engine with interlocking for operation of main fire pumpsE-1)for 5.5/ 7.5 kW centrifugal type booster pump 1no(1working) , add Rs 18893.70Total:- FCP + A-2 + B-3 + C-3 + D + E-1 = 182320+47686+161675+33616+68381+17994 =511672+5% = 537255.60 |
| 818 | Supplying and erectingG.I. pipe‘C’ class ERW25 mm dia with necessary fittings complete asper specification no. FF-PP |
| 819 | Supplying and erectingG.I. pipe‘C’ class ERW50 mm dia with necessary fittings complete asper specification no. FF-PP |
| 820 | Supplying and erectingG.I. pipe‘C’ class ERW75/80 mm dia with necessary fittings complete asper specification no. FF-PP |
| 821 | Supplying and erectingG.I. pipe‘C’ class ERW100 mm dia with necessary fittings complete asper specification no. FF-PP |
| 822 | Supplying and erectingG.I. pipe‘C’ class ERW150 mm dia with necessary fittings complete asper specification no. FF-PP |
| 823 | Supplying and erectingG.I. pipe‘C’ class ERW200 mm dia with necessary fittings complete asper specification no. FF-PP |
| 824 | Supplying anderecting100 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SSscreen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) forpositive suction complete asper specification no. FF-VL/ELS |
| 825 | Supplyinganderecting100mm dia.castiron double flange sluicevalvecomplete with PN16 pressure rating, asper specification no. FF-VL/SV |
| 826 | Supplying and erecting 50 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, asper specification no. FF-VL/BFV |
| 827 | Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, asper specification no. FF-VL/BFV |
| 828 | Supplying and erecting 150 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, asper specification no. FF-VL/BFV |
| 829 | Supplying and erecting 100 mm diacast iron double flange NRV complete with PN16 pressure rating, asper specification no. FF-VL/NRV |
| 830 | Supplying and erecting50 mmdiagunmetal gatevalvecomplete with PN16 pressure rating, asper specification no. FF-VL/GV |
| 831 | Supplying anderectingstainless steel single outlethydrantvalve fitted with necessary accessories complete asper specification no. FF-VL/HV |
| 832 | Supplying and installing wall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose)along with necessary accessories complete asper specification no. FF-FFA/HV |
| 833 | Supplying and erecting 63mm dia, reinforced rubber lined (R.R.L.) hose pipe,15m inlength, fitted with necessary accessories complete asper specification no. FF-FFA/RRL |
| 834 | Supplying and erecting stainless steel branch pipe 63 mm dia fitted with 20 mm dia detachable hexagonal nozzlecomplete as per specifications no. FF-FFA/NZ |
| 835 | Supplying and erecting fire brigade header ( Siamese connection )of 150 mm dia, for supplying water in fire tank complete asper specification no. FF-FA/FMC |
| 836 | Supplying and erecting300 mm dia 1.5min heightair vessel / tankfabricated from min 5mm thick M.S. sheet complete asper specification no. FF-FFA/ACT |
| 837 | Supplying anderecting20/25mm dia gun metal air release cock, with necessary G.I.coupling to be fitted on top of air vessel or on wet riser complete asper specification no. FF-FFA/ARV |
| 838 | Supplying and erecting 100 mm dia. pressure gauge , 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, erected with provided G.I. pipe, elbow etc. complete asper specification no. FF-FFA/PG |
| 839 | Supplying and erecting12/15 mm dia pressureswitchwith provided isolationvalve,G.I. nipple, elbow, etc complete asper specification no. FF-FFA/PS |
| 840 | Supplying and erecting M.S./CRCA cabinetfor housingFloorHydrant valve,hosepipe,hosereeland branch pipe(size 1000 x 736 x 736mm.)madefrom16SWG sheetandangle iron 25 x 25 x 4 mm. having front doors with viewingglass(8\"x6\") andlocking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5) |
| 841 | Supplying, erecting testingand commissioningoptical type smoke detectoron suitable back box with necessary connections complete asper specification no. FF-FAS/SD |
| 842 | Supplying, erecting, testing and commissioning manual call point (Pill box) with break glass push button andflip abort switch or agent release switch in metal enclosure complete asper specification no. FF-FAAS/MCP |
| 843 | Supplying, erecting, testing and commissioning hooters having high (100dB @ 1m) and low (94dB @ 1m) volume setting, group addressing facility allowing multiple sounders to be activated with CRCA enclosure complete asper specification no. FF-FAAS/HTR |
| 844 | Supplying, installing, testingand commissioning FR, XLPE armouredcable 2 core1.5 sq.mm. copper conductorcomplete erected on wall/ ceiling complete asper specification no. CB-LT/CU |
| 845 | Supplying, installing, testingand commissioning of 4 Zones Microprocessor based conventional fire alarm control panel (FACP) with standard accessories , 16x2CharacterLCDDisplay, provision for zone wise contact and beep sound alarm, suitable to operate on 120-220 V AC,0 - 49 Deg C,93 ± 2 Percentage RH (non- condensing) at 32± 2 Deg C complete asper specification no. FF-FAAS/FACP ( Add 50% for Additional 2 zone Rs 8919.50/- ; Base Price Rs 17839 + 8919.50 = 26758/- Add 5% Total - 28096.45 |
| 846 | Supplying, erecting,testing and commissioning 120 W amplifiersuitable to operate on 230VoltsA.C. / 12VoltsD.C. supply complete asper specification no. FF-PA/AFR |
| 847 | Supplying,erecting, testing and commissioning 15 to 30 Watts soundcolumn or ceiling mounted complete asper specification no. FF-PA/SOC |
| 848 | Supplying,erecting, testing and commissioning stand mounted/handheld type wired microphone having 2 mV/Pa sensitivity, impedance level limit 300 ohms and 50 - 16000 Hz suitable to operate in -10 deg C to +55 deg C with min. 7 metreshielded cable and 3 Pin Professional XLR Connector, stereo jack complete asper specification no.FF-PA/MIC |
| 849 | Supplying, erecting, testing and commissioning of 0.5 sq. mm speaker wire complete. |
| 850 | Supplying, erecting, testing and commissioning of quartzoid bulb sprinkler, 15 mm (½\") dia. NBCM Body chrome finished, 68º C fixed temperature rating with deflector disc of conventional construction complete as per specification no. FF-SPR. |
| 851 | Supplying, erecting, testing and commissioning vane type water flow detector100 mm dia. with1) Visual switch activation 2) Rugged switch assembly 3) Heavy duty aluminium pipe saddles 4)Durable metal enclosure 5) Steel U bolts for secure mounting 6) Two SPDT ( Single pole double track ) synchronised switches 7) serviceable without draining pipes. |
| 852 | Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete. |
| 853 | Supplying and erecting ABC powder type fire extinguisheras per IS : 13849 /15683 of 6 kg capacity with necessaryclamp for erection on wall. |
| 854 | Supplying & installation auto glow/self Luminous (Viewing upto 15 mtr length) fire signages Fire Exit, Fire Hydrant,Hose Box, MCP, Hooter, Fire Alarm Control Panel & Fire Exinguisher signage Indicating the detail. With BS5499 as per sample approved by incharge. |
| 855 | Providing and erecting 545 to 550 Watt Framed Dual Glass Bi-Fecial Solar Module Panel Having Mechnical Cheracterics of 2272x1133x35 (LxWxT), Weight 333 KG, Front Glass 2 mm Low Iron HTAR semi-tempered glass and Back Glass 2 mm Low Iron Printed semi-tempered glass,Having Electrical Characterics of Vmp of 41-43 Volt DC, Current 13A DC, Juncton Box IP65, MC4 Cable Connector with Sq mm, 500mm Cable including in Panel Junction Box. Bifecial Power output at 30% Rediation 700W, at Module Efficiency of 27% With 5 Years of On-Site Warrenty. |
| 856 | Providing and erecting of Transformerless Solar On Grid String Inverter of Capacity of 25KW, Having Mechnical Cherecterics of IP65 Rating, Multi Information LCD Display. Built in Wifi, DC Switch, Electrical Characterics of 1100V DC Input Voltage, Input Power of 1200W DC, MPPT Voltage Range of 200 to 950V, Startup Voltage of 180V, Nominal Output Power 25KW AC, Output Voltage of 400V, 3Ph, 5 Wire AC(3L/N/PE), Max Output Current of 15A AC, with Powerfactor Adjustable to +0.80 to -0.80. Max Efficiency 98.50%Including all Accessories like ACDB, DCDB, Wiring, Earthing, DC & AC Cables of Appropriate sizes. |
| 857 | Supplying and erecting switch disconnector fuse (SDF) 415V, 160A, with enclosure, four poleAC23 A rated with terminal shrouds on both sides and phase barriers along with telescopic shaft for depth adjustments and door interlock and padlock complying to IS/IEC 60947-3 Part-1/3 HRC - DIN type fuse switch, insulation voltage 1000 V , with rotary handle for ON / OFF operation(without HRC fuse) |
| 858 | Supplying and erecting metal work in CRCA sheet including Iron work for supportswith fabrication ofboxes,panelboards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment andduly powder coated or paintedwith one coat of red lead paint and 2 coats of enamel paint complete. |
| 859 | Supplying and erecting marine (Waterproof) plywood 18/19 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners, supports, nut bolts etc. complete with compliance to IS 720:2010FR plywood with compliance to IS 5509:2000 |
| 860 | Supplyinganderectingiron work, sheet metal work consisting of CRCAsheets, varioussectionsofiron,plates, chequeredplates,rods,bars,MSpipes,etc. forpanel board or any other purpose with bending, cutting, drilling and welding completeerectedatthepositionwith necessarymaterialsdulypaintedwith one coat of red oxide and two coats of enamelpaint to match the switchgears or as per directions by the authority.(Mono Rails 75x3 = 225Nos, 3KG x 225 = 675KG) |
| 861 | SupplyinganderectingstaticenergyTrivector meter440 V50 Hz. 20-100AISImarkmeter AC 3 phase 4 wires LCD/LED display (Measuring and display Trivector, V, I, kW, PF, Hz, Last month history of kWh & MD in kW) with special features like TOD, Tamper logging, Optical Communication Port & Display in absence of Power complete erected on polishedteak wood board duly wiredwithrequiredsize of weatherproof PVC wires duly tested for class 1.0 accuracy by electric supply company. (Use as Solar Generation Meter) |
| 862 | SupplyinganderectingAC three phase HT CT multifunctionnet meterDLMS compliance of accuracy class 0.5, 3x 63.5V, 50Hz,with backlitLCD display, optical port& RS 232 port( measures import kWh, kVAh, export kWh, kVAh, net kWh, kVAh, V, I, kW, 6 months history of energy, load survey, TOD, tamper detection & logging, power ON/OFF events, instantaneous parameters of rating 1/5A with display in absence of power)with wiring connections and mountinghardwareonprovidedpanelscompletewith calibration certificate from manufacturer. |
| 863 | Making cement concretefoundationin 1:3:6 cement concrete,(20 to 25) mm. stone metal duly plastered with necessary curing forcomplete. (pole muffing or any other purpose). |
| 864 | Supplying, erecting & terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core185 sq. mm. aluminiumconductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL |
| 865 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 200 mmoutside dia, double wall corrugatedpipes (DWC)ofHDPE for enclosing cable below ground/road surface, to required depth complete. |
| 866 | Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results asper specification no. EA-EP |
| 867 | Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clampsfixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. |
| 868 | Supplying, erecting, testing and commissioning of diesel generating set with alternator of 200 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 1 %, with performance class G2 and maximum fuel consumption 34.40 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 1.4/1.5 mm thickness MS Sheet, sound absorbing material to restrict sound level up to 75 dB(A) at 1.0 m, provided with first filling of oil, diesel not less than 300 Ltr etc. on provided M20 Grade CC Foundation, complying to CPCP IV norms with STD AMF panel complete. Approved by SE Office Nagpur Vid letter no.520 Dt.20/02/2024. |
| 869 | Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 180 kVA up to 200 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF. (194306.70-10% = 174876.03) |
| 870 | Excavating soft murum / soft soil road by chiselling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site good complete. |
| 871 | Making cement concretefoundationin 1:3:6 cement concrete,(20 to 25) mm. stone metal duly plastered with necessary curing forcomplete. (pole muffing or any other purpose). |
| 872 | Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 873 | Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 874 | Supplying and erecting PVC insulated PVC round sheathed 4 sq.mm (56 no. x 0.30 mm dia.) 3 core flexible multi strandedcopper Industrial cable for voltage grade up to 1.1 kV (For IDU) |
| 875 | Supplying and erectingmodular type D.P. switch 32A with indicator, duly erected on provided plate and box with wiring connections complete. |
| 876 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 877 | Supplying, erecting, testing and commissioning of 12HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000m operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete. (9Court+Library/VC+Conference) |
| 878 | Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact/standard size) of nominal cooling capacity 2.0TR (618 cfm) to 2.3TR (671 cfm) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation. |
| 879 | Supply, installation, testing and commissioning wireless remote control having colour LCD panel, real time clock, temperature limitation (16 to 30° C, functions like filter clean reminder timer suitable to communicate with wired controller complete. |
| 880 | Supplying and installation of high pressure grade required size copper connection Y or T- Joints/refnet complete erected on wall/ceiling with supports/raceways, Nitrile rubber insulation, painting etc. with brazing and testing for leakages confirming the normal operation of the VRV/VRF air conditioning system. |
| 881 | supplying, laying/fixing, testing and commissioning ofappropriate nominal refrigerant copper pipe of 22.2mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiation with OEM standards of VRV/VRF air conditioning system complete. |
| 882 | supplying, laying/fixing, testing and commissioning ofappropriate nominal refrigerant copper pipe of 19.1mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiations with OEM standards of VRV/VRF air conditioning system complete. |
| 883 | supplying, laying/fixing, testing and commissioning ofappropriate nominal refrigerant copper pipe of 12.7mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiations with OEM standards of VRV/VRF air conditioning system complete. |
| 884 | Supplying and erecting 12/16 mm (ID/OD) Chlorinated polyvinyl chloride pipe (CPVC), thickness 1.7 mm conforming to IS 15778 (CTS Series) with necessary CPVC fittings and solvent cement for Solar Water Heater System as per specification No. ESD-HWP/CPVC |
| 885 | Supplying, erecting & marking SPMCB 6A to 32A, C-serieswith rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 886 | Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 887 | Supplying&erectingtriplepole and neutral distribution board (TPNDB), SP/TP MCBs total 4 ways /12 Poles, with door, 1.2mm thickness surface/flushmounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB |
| 888 | Supplying, erecting & commissioning 4 pole RCCB 63A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication completeas per specification no. SW-RCCB/RCCB |
| 889 | Supplyinganderectingiron work, sheet metal work consisting of CRCAsheets, varioussectionsofiron,plates, chequeredplates,rods,bars,MSpipes,etc. forpanel board or any other purpose with bending, cutting, drilling and welding completeerectedatthepositionwith necessarymaterialsdulypaintedwith one coat of red oxide and two coats of enamelpaint to match the switchgears or as per directions by the authority. |
| 890 | Supplying, erecting& terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 891 | Supplying, installation and testing of maintenance free earthing comprising of Electrode of 17.2 mm diameterLow Carbon Steel with 250 micronmolecular copper bonded earthing rod ofLength 3malong with 25 kg Carbonbased environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete, and recording the results Specification no. EA-MOBI |
| 892 | Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete. |
| 893 | Supplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi strandedcopper Industrial cable for voltage grade up to 1.1 kV |
| 894 | Supplying and erecting integrated LED street light fitting 70-75W IP65 & IK08 class having single piece pressure die-cast aluminium housing,havingsystem lumens output of Min. 7700 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50,including driver complete with 3 Years warranty as per specification NoFG-ODF/FLS2. |
| 895 | Supplying & erecting three phase, 415V, street light control panel up to the max load of 6kW, TPN MCB 40A,powder coated CRCA 14 SWG sheet, outdoor type, having IP54,IK10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up,auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protectionon provided iron frame / CC foundation. |
| 896 | Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 897 | Supplying, erecting & terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core6sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL |
| 898 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core16sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL |
| 899 | Supplying andlaying (including excavation of suitable width & depth up to 90 cm) 50 mmoutside dia. double wall corrugatedpipes(DWC) ofHDPE for enclosing cable below ground/road surface, to required depth complete. |
| 900 | Providing & erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL |
| 901 | Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT |
| 902 | Providingpipetype earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rodcomplete with all materials testing and recording the results as per specification no. EA-EP |
| 903 | Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete. |
| 904 | MakingM- 20 grade reinforced cement concretefoundation by considering the safe soil bearing capacity at site as 10 T/sq.mat 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal /conical GI pole). |
| 905 | Supplying and erecting mains with 2x1.5 sq.mm FRLSHcopperPVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 906 | Supplying and erecting mains with 1x1.5 sq.mm FRLSHcopperPVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 907 | Supplying and erecting mains with 2x2.5 sq.mmFRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 908 | Supplying and erecting mains with 1x2.5 sq.mmFRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 909 | Supplying and erectingmodular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. |
| 910 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 4 module duly erected. |
| 911 | Supplying and erectingbulk head LED fittingmax. 10Wwith high transitivity diffuser withsystem lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg.,THD<10%,p.f. >0.95, operating range of140-260V, in built surge protection of 2.5 kV, Life class of50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty. |
| 912 | Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 913 | Supplyingand erecting single pole and neutral distributionboard (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB |
| 914 | Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame. |
| 915 | Supplying, erecting & commissioning 2 pole RCCB 16/25A, electromagnetic type with 30/100/300 mA sensitivitywithearth leakage trip indicationcomplete as per specification no. SW-RCCB/RCCB |
| 916 | Supplying, erecting & commissioning 2 pole RCCB 63A, electromagnetictype with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB |
| 917 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 10sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL |
| 918 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core25sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL |
| 919 | Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results asper specification no. EA-EP |
| 920 | Providingpipetype earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rodcomplete with all materials testing and recording the results as per specification no. EA-EP |
| 921 | Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete. |
| 922 | SITC of Electric Traction Passenger Liftwith · Rated capacity :- 8 Passenger/544Kg· Floors :-G+4 floor (5 Stops/5 Landings) · Travel :-3 to 4.2 mtrs · Location of Lift Machine:- MR/MRL· Rated speed :- 1.0 mps VS · Car/Landing doorclear opening of 800 mm wide x 2000 mm high · Clear Carsize of......mm wide x ......mm deep x2250mm high · Lift shaft available having clear size of......mm wide x ......mm deep,......mm Pit depth, ………mm Overhead. · Doorstype :- COPO/TOPO Doors with framemade from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory). · Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge. · COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor. · LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings. · Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor andtravel direction protection, protection for phase loss at input or outputetc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility,auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters.The control panel duly wired with proper size & strength,copper wire forpower & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. · Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor andtravel direction protection, protection for phase loss at input or outputetc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility,auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters.The control panel duly wired with proper size & strength,copper wire forpower & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class.· ARD complete with necessary SMF VRLA batteries. · Fireman controller having fireman switch at fire Landing. · CCTV surveillance system comprises of 2 nos minimum 2.0 MP FHD IP based vandal proofDome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup min. 90 days with min. 18” FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge. · Lift Machineof Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory),with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength.· Other mechanical parts such as \"T\" section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work. · Minor civil work such as alteration work if any necessary for erection of landing door frames and it\"s accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixingsteel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT.· General: - Job includes entire procedure of obtaining all necessary erection permissions & \"License to Work the Lift\" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. · The above rate includes Fully Comprehensive AMC for one year from the date of commissioning. |
| 923 | SITC of Electric Traction Passenger Liftwith · Rated capacity :- 10 Passenger/680Kg· Floors :-G+4 floor (5 Stops/5 Landings) · Travel :-3 to 4.2 mtrs · Location of Lift Machine:- MR/MRL· Rated speed :- 1.0mps VS · Car/Landing door clear opening of 800 mm wide x 2000 mm high · Clear Carsize of......mm wide x ......mm deep x2250mm high · Lift shaft available having clear size of......mm wide x ......mm deep,......mm Pit depth, ………mm Overhead. · Doorstype :- COPO/TOPO Doors with framemade from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory). · Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge. · COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor. · LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings. · Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor andtravel direction protection, protection for phase loss at input or outputetc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility,auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters.The control panel duly wired with proper size & strength,copper wire forpower & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. · ARD complete with necessary SMF VRLA batteries. · Fireman controller having fireman switch at fire Landing.· CCTV surveillance system comprises of 2 nos minimum 2.0MP FHD IP based vandal proofDome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for min. 90 days with min.18” FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge. · Lift Machineof Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory),with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength. · Other mechanical parts such as \"T\" section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work.· Minor civil work such as alteration work if any necessary for erection of landing door frames and it\"s accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixingsteel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT. · General: - Job includes entire procedure of obtaining all necessary erection permissions & \"License to Work the Lift\" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. · The above rate includes Fully Comprehensive AMC for one year from the date of commissioning. |
| 924 | SITC of Electric Traction Passenger cum Stretcher/HospitalLiftwith · Rated capacity :- 20 Passenger/1360Kg· Floors :-G+4 floor (5 Stops/5 Landings)· Travel :- 3 to 4.2 mtrs · Location of Lift Machine:- MR/MRL · Rated speed :- 1.0mps VS · Car/Landing door clear opening of 1100/1200 mm wide x 2000 mm high · Clear Carsize of......mm wide x ......mm deep x2250mm high · Lift shaft available having clear size of......mm wide x ......mm deep,......mm Pit depth, ………mm Overhead. · Doorstype :- COPO/TOPO Doors with framemade from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory) · Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge. · COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor. · LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings. · Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor andtravel direction protection, protection for phase loss at input or outputetc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility,auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters,The control panel duly wired with proper size & strength,copper wire forpower & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. · ARD complete with necessary SMF VRLA batteries. · Fireman controller having fireman switch at fire Landing. · Minor civil work such as alteration work if any necessary for erection of landing door frames and it\"s accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixingsteel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT. · CCTV surveillance system comprises of 2nos minimum 2.0MP · General: - Job includes entire procedure of obtaining all necessary erection permissions & \"License to Work the Lift\" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. · The above rate includes Fully Comprehensive AMC for one year from the date of commissioning. FHD IP based vandal proofDome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for min. 90 days with min. 20\" FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge. · Lift Machineof Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory),with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength. · Other mechanical parts such as \"T\" section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work. |
| 925 | For Lift having 1000mm wide x 2000mm high clear entrance in 1.5mm thickSS 304 grade solid(non-cladded) landing door [Two panel], this includes allnecessary accessories like LOP\"s with UP/DN buttons-arrows-indicators,extension of guide rails, shaft wiring with trunking, travelling cables, mainhoisting ropes/belts, & OSG rope landing doors with all accessories etc. necessary for the normal safe functioning of lift installation complete. |
| 926 | For Full Collective control system,For Lift travelling above First floor & up to Sixth floor (Base Rate 28707 x 6 Nos Lifts = 1,72,242/-) |
| 927 | Supplying and erecting HMS PVC conduit FRLS grade 20 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 928 | Supplying and erecting PVC insulated PVC round sheathed 1 sq.mm (32 no. x 0.20mm dia.) 3 core flexible multi strandedcopper Industrial cable for voltage grade up to 1.1 kV |
| 929 | Supplying and installingcat-6 cable suitable for networking as per specification no. WG-COC/NC |
| 930 | Supplying, fixing, and configuring 8-ports managed gigabit, Layer-2 switch, 10/100/1000 base-T, POE smart switch plus 2 SFP erected in provided rack complete. |
| 931 | Supplying, erecting, testingandcommissioning of 3kVA capacity onlinepure sine wave with backup time of 6 hrs. PWM & IGBT based UPS with 0.8 to unity output pf, single phase input & 1 phase output complete with all protectionsas per specification no. AP-UPS |
| 932 | Supplying and erecting 12V/42Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete |
| 933 | Supplying& erecting of High definition 4/5 Megapixel IP IR Bullet Camera with following featuresImage Sensor : minimum 1/2.8\" Progressive Scan CMOS,Video Resolution : minimum 2592 x 1520Video Compression : H.264, H.265 or higher, at least Three individually configurable stream,Frame rate : minimum 25 fps at all resolutions,WDR : minimum 120 dB Wide Dynamic Range,ONVIF profile conformant,minimum IR distance : 50m, Lens Type : 2.8/4/6 mm Lens, fixed focal,Field of View :2.8 mm, horizontal FOV 107°, vertical FOV 57°, diagonal FOV 129°4 mm, horizontal FOV 86°, vertical FOV 47°, diagonal FOV 102° 6 mm, horizontal FOV 55°, vertical FOV 29°, diagonal FOV 65°Lux sensitivity - minimum 0.2 Lux at color, minimum 0.05 Lux at Black & White, 0.0 Lux (IR) Night Vision Distance minimum IR - 50m. Camera minimum Adjustment Angles - Pan : 350°, Tilt : 72°, Rotate : 350°. Power Supply : Support 12VDC & PoE,IP67, IK10 - Vandal Resistant.Built in micro SD/SDHC/SDXC card slot of minimum 128 GB,Built in microphone. minimum Input/Output - Audio in × 1, Audio Out × 1, Alarm in × 1, Alarm Out × 1.Image Settings : Rotate mode, saturation, brightness, contrast, sharpness, gain, white balance. Image Enhancements : Day/Night-Auto (ICR)/Color/Black & White, 3D Digital Noise Reduction, Automatic White Balance, Automatic Gain Control, Backlight Compensation, Highlight Compensation. Events : Privacy Masking, Motion detection, Scene change detection, Face capture, Video tampering, audio exception detection, Region entrance detection, Region exiting detection.Operating temperature ( -30 to 60° C ) .Security - User account and password protection, HTTPS, IP filter, IEEE 802.1X, digest authentication, user access log, TLS1.2, AES - 256, SSH/Telnet closed, FTP disabled. Protocol - DHCP, UDP, HTTP, HTTPS, NTP, DNS, RTP, RTSP, SMTP, SSL/TLS, TCP/IP, Secure Real-Time Transport Protocol (SRTP), Bonjour, SNMP and Secure shell (SSH) supported protocol.RoHS, WEEE, ISO-14001 and REACH compliant, UL/EN OR equivalent BIS/TECH/STQC or any indian standards as applicable, CE, FCC certified.duly erected in position on wall/ceiling/false ceiling/provided pole (mounting height not more than 5 meter) etc with all accessories etc complete as per specification no. CCTV-CAM (NCSR Rates Approved By SE Office Nagpur Vid. Letter No. 1226 Dt 20/05/2024) |
| 934 | Supplying& erecting of High definition 4/5 Megapixel IP IR Dome Camera with following features Image Sensor : minimum 1/2.8\" Progressive Scan CMOS,Video Resolution : minimum 2592 x 1520Video Compression : H.264, H.265 or higher, at least Three individually configurable stream,Frame rate : minimum 25 fps at all resolutions,WDR : minimum 120 dB Wide Dynamic Range,ONVIF profile conformant,minimum IR distance : 50m, Lens Type : 2.8/4/6 mm Lens, fixed focal, Field of View :2.8 mm, horizontal FOV 107°, vertical FOV 57°, diagonal FOV 129°4 mm, horizontal FOV 86°, vertical FOV 47°, diagonal FOV 102°6 mm, horizontal FOV 55°, vertical FOV 29°, diagonal FOV 65°Lux sensitivity - minimum 0.2 Lux at color, minimum 0.05 Lux at Black & White, 0.0 Lux (IR) Night Vision Distance minimum IR - 50m. Camera minimum Adjustment Angles - Pan : 350°, Tilt : 72°, Rotate : 350°. Power Supply : Support 12VDC & PoE, IP67, IK10 - Vandal Resistant. Built in micro SD/SDHC/SDXC card slot of minimum 128 GB,Built in microphone. minimum Input/Output - Audio in × 1, Audio Out × 1, Alarm in × 1, Alarm Out × 1.Image Settings : Rotate mode, saturation, brightness, contrast, sharpness, gain, white balance. Image Enhancements : Day/Night-Auto (ICR)/Color/Black & White, 3D Digital Noise Reduction, Automatic White Balance, Automatic Gain Control, Backlight Compensation, Highlight Compensation. Events : Privacy Masking, Motion detection, Scene change detection, Face capture, Video tampering, audio exception detection, Region entrance detection, Region exiting detection.Operating temperature ( -30 to 60° C ) .Security - User account and password protection, HTTPS, IP filter, IEEE 802.1X, digest authentication, user access log, TLS1.2, AES - 256, SSH/Telnet closed, FTP disabled. Protocol - DHCP, UDP, HTTP, HTTPS, NTP, DNS, RTP, RTSP, SMTP, SSL/TLS, TCP/IP, Secure Real-Time Transport Protocol (SRTP), Bonjour, SNMP and Secure shell (SSH) supported protocol.RoHS, WEEE, ISO-14001 and REACH compliant, UL/EN OR equivalent BIS/TECH/STQC or any indian standards as applicable, CE, FCC certified.duly erected in position on wall/ceiling/false ceiling/provided pole (mounting height not more than 5 meter) etc with all accessories etc complete as per specification no. CCTV-CAM(NCSR Rates Approved By SE Office Nagpur Vid. Letter No. 1226 Dt 20/05/2024) |
| 935 | Supplying& erecting of High definition 4/5 Megapixel IP IRPTZ Camera with following featuresImage Sensor : minimum 1/2.8\" Progressive Scan CMOS Video Resolution:minimum 2880 x 1620 Video Compression : H.264, H.265 or higher, at least Three individually configurable stream,Frame Rate : minimum 30 fps at all resolutions,WDR : minimum 120 dB Wide Dynamic Range,ONVIF profile conformant.Auto Tracking, Pre-set Tour Settings, Pan : 360° endless, Tilt : From -15° to 90° (auto-flip 180°), minimum Pan Speed - from 0.1°/s to 160°/s, minimum Preset Speed: 240°/s, minimum Tilt Speed - from 0.1°/s to 120°/s, minimum Preset Speed : 200°/s, Min Presets- 250,Min IR distance :150m,Lens Type : minimum 4.3 - 12.5mm Lens min 16 x digital zoom, min 30 x optical Zoom. Focus Mode : Auto/Zooming/One Push Manual, Lux sensitivity- minimum 0.2 Lux at color, minimum 0.05 Lux at Black & White, 0.0 Lux (IR) Night Vision Distance Min IR- 150m,Power Supply : support 12/24 VDC, 24 VAC &PoE,IP67/IP66, IK10, built in micro SD/SDHC/SDXC card slot minimum 256 GB,built in microphone. (NCSR Rates Approved By SE Office Nagpur Vid. Letter No. 1919 Dt 04/12/2023) minimum Input/Output : Audio in × 1, Audio Out × 1, Alarm in× 1, Alarm Out × 1.Image Settings : Rotate mode, saturation, brightness, contrast, sharpness, gain, white balance.Image Enhancements : Day/Night-Auto (ICR)/Color/Black & White, 3D Digital Noise Reduction, Automatic White Balance, Automatic Gain Control, Backlight Compensation, Highlight Compensation. Events : Privacy Masking,Motion detection, Scene change detection, Face capture, Video tampering, audio exception detection, Region entrance detection, Region exiting detection.Operating temperature ( -30 to 60° C ) .Security : User account and password protection, HTTPS, IP filter, IEEE 802.1X, digest authentication, user access log, TLS1.2, AES-256, SSH/Telnet closed, FTP disabled. Protocol-DHCP, UDP, HTTP, HTTPS, NTP, DNS, RTP, RTSP, SMTP, SSL/TLS, TCP/IP, Secure Real-Time Transport Protocol (SRTP),Bonjour, SNMP and Secure shell (SSH) supported protocol.RoHS, WEEE, ISO-14001 and REACH compliant, UL/EN OR equivalent BIS/TECH/STQC or any indian standards as applicable, CE, FCC certified duly erected in position on wall/ceiling/false ceiling/provided pole (mounting height not more than 5 meter) etc with all accessories etc complete as per specification no CCTV-CAM. (NCSR Rates Approved By SE Office Nagpur Vid. Letter No. 1226 Dt 20/05/2024) |
| 936 | Supplying, installing, testing & commissioning of 32/40 Ch. Network Video Recorder (NVR), suitable connect Min. 32 IP Cameras, up to 5 Megapixel Resolution, with HDMI/VGA outputs, provided HDMI output of 4K resolution or VGA output with output up to 1920 × 1080. Support H.265 or higher, H.264, MJPEG, Incoming Bandwidth 250Mbps with minimum 4 SATA Hard Disks, ANR Technology,4 SATA interfaces for 4 HDDs and capacity of each HDD up to 8TB, minimum 02 USB port, Alarm I/O16/4, RJ-45 10/100/ 1000 Mbps self-adaptive Ethernet interface,ONVIF conformance,Multiple network monitoring: Web viewer . support protocol TCP/IP, DHCP, DNS, DDNS, NTP, SADP, SMTP, NFS, iSCSI, UPnP™, HTTPS.RoHS, UL, CE, FCC certified duly erected in provided U Rack with wiring connections, tagging and programming etc. complete as per specification no. CCTV-NVR (NCSR Rates Approved By SE Office Nagpur Vid. Letter No. 1226 Dt 20/05/2024) |
| 937 | Supplying& erecting 8 TB internal Surveillance HDD suitable for SATA Port of NVR, interface transfer rate 6 GB/S,maximum sustained transfer rate 210 MB/Sec to 213 MB/S. Drive bay supported 08+, Cameras supported up to 64,Cache (MB) 256, Load/Unload Cycle -3000000, Work Load Rating per Year 180TB,MTBF 1000000 Hrs. HTTPS.RoHS, UL, CE certified, duly erected in position in provided NVR as per specification no. CCTV-HDD (NCSR Rates Approved By SE Office Nagpur Vid. Letter No. 1226 Dt 20/05/2024) |
| 938 | Supplying& erecting 43\" professional LED display with 1920*1080 (Full HD) Display, suitable for 16/32 channel NVR and following features Brightness: minimum 500 Cd/m2Contrast Ratio: minimum 1000:1Viewing angle: 178/178 deg.Response time: maximum 8 ms Inputs: HDMI, VGA, BNC,USB, Audio In, Built-in speakers maximum 10 W, Suitable to operate on 100-240 V 50 Hz AC supply and 24/7 Duty Cycle duly erected on wall or table top with standard accessories like wall mount stand and wiring connections etc. complete as per specifications no. CCTV-MON (NCSR Rates Approved By SE Office Nagpur Vid. Letter No. 1226 Dt 20/05/2024) |
| 939 | Supplying and erecting HMS PVC conduit FRLS grade25 mm dia. with PVC accessories on wall /ceiling as per specification No: WG-MA/CON. |
| 940 | Supplying and erecting mains with 2x2.5 sq.mmFRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 941 | Supplying and erecting mains with 1x2.5 sq.mmFRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 942 | Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 943 | Supplying and erecting mains with 1x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 944 | Supplying and erectingmodular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. |
| 945 | Supplying and erectingmodular type switch 16Aduly erected on provided plate and box with wiring connections complete. |
| 946 | Supplying and erectingmodular type 3 pin 6 / 16Amultisocket with safety shutter,duly erected on provided plate and box with wiring connections complete. |
| 947 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 6module duly erected. |
| 948 | Supplying, erecting & marking SPMCB 6A to 32A, C-serieswith rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 949 | Supplying, erecting & marking DPMCB 40A to 63A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 950 | Supplying&erectingtriplepole and neutral distribution board (TPNDB), SP/TP MCBs total 4 ways /12 Poles, with door, 1.2mm thickness surface/flushmounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB |
| 951 | Providing, erecting & commissioning 4 pole RCCB 63A, with added immunity to avoid DC pulse tripping with 30/100/300 mA sensitivitycomplete as per specification no. SW-RCCB/RCCB |
| 952 | Supplying, erecting & terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core10sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL |
| 953 | Supplying andlaying (including excavation of suitable width & depth up to 90 cm) 50 mmoutside dia. double wall corrugatedpipes(DWC) ofHDPE for enclosing cable below ground/road surface, to required depth complete. |
| 954 | Supplying and erecting minimum Three & above star rated submersible pump set of 3.75 KW/5 HP with 415 V, 50 c/s AC supply suitable for 150 mm dia. borewell suitable for 60 to 290 LPM discharge at 112 to 12 m head & discharge & delivery Pipe of Size-50mm diameter with a necessary H type clamps as per specification No. WP-SMP (Borewell Depth = 60Mtr) |
| 955 | Supplying and erecting minimum Three & above star rated submersible pump set suitable for erection on open well of 2.25 KW/3 HP with 415 V 50 c/s. A.C. supply, having delivery head from 27 to 9 m and discharge from 300 to 660 litres. per minute &pipe of Suction 65mm /Delivery 50 mm diameter erected with necessary H type clamps as per specification No. WP-OSP |
| 956 | Supplying & erecting flat flexible 3 core 4 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. |
| 957 | Supplying & erecting automatic control panel for 3 Phase , 415 volt, A.C, Submersible/centrifugal pump set up to 7.5 HP consisting of DOL starter having relay range 9-14 AMP,S.P.P., Combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc . |
| 958 | Making cement concretefoundationin 1:3:6 cement concrete,(20 to 25) mm. stone metal duly plastered with necessary curing forcomplete. (pole muffing or any other purpose). |
| 959 | Supplying and erecting ISI mark GI pipe 50 mm dia.‘B’ class at position with accessories complete as per specification no. CW-PLB/GP. |
| 960 | Supplying and erecting non return valve 50 mm dia in position made of gun metal complete. |
| 961 | Supplying and erecting CI flange 50 mm. dia with necessary nuts bolts and washers with rubber seal in position complete. |
| 962 | Supplyinganderectingiron work, sheet metal work consisting of CRCAsheets, varioussectionsofiron,plates, chequeredplates,rods,bars,MSpipes,etc. forpanel board or any other purpose with bending, cutting, drilling and welding completeerectedatthepositionwith necessarymaterialsdulypaintedwith one coat of red oxide and two coats of enamelpaint to match the switchgears or as per directions by the authority. |
| 963 | Supplying,erecting,testing and commissioning 11KV HT metering cubical (compact / vertical type) approved by MSEDCL / licensee fabricated with 2 mm (14 SWG) M.S. sheets with supporting angle, painted with powder coating / epoxy paintof required shade, copper bus bar size 25 x 6 mm, heavy duty mechanical lock, with counter meter for measuring no of times the opening of meter door, top side cover (CT, PT cover) interlock with meter door, epoxy casted 3 nos. CT having required ratio between 50/5A to 200/5A, VA 10 or 15, Class 0.2S, epoxy casted 3 nos. PT having ratio 11000/V3/110/V3 VA 50, Class 0.2 suitable for provided trivector meter, andprovision for incoming and outgoing cables complete duly tested by licensee with necessary test certificatesand erected on provided plinth/ cc foundation. |
| 964 | Supplying, installation, testing and commissioning extendable/non-extendable outdoor type 11 kV 630A,load break isolator switch, compliant to IEC 62271 -100, 200 and 102,on provided MS channels/trench/foundation as per specification no SW-HTS / LBS |
| 965 | Supplying, erecting & terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core300 sq. mm. aluminiumconductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL |
| 966 | Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable11 kV(E), 3 x 300 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT |
| 967 | Providing and erecting Heat shrinkable out door termination kit for 11 kV ( E ) XLPE HT cable 3x240 to 300 sq. mm. with necessary material as per specification no. CB-JT/HT |
| 968 | Supplying & laying (including excavation) half round reinforced cement concrete pipe of IS 458:2003 NP-2 class of 250 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. |
| 969 | Supplying and erecting rolled steel joist (girder) pole 100 x 116 mm (23 kg/m) with base plate in provided foundation as per specification no. OH-PL/RSJ (5 Pole HT Line , + DP Termination Structure with Studs) |
| 970 | Supplying and erecting V cross arm with ISM channel of75x40x6mmfor 11kV HT OH line with arrangement to fix insulator at 45mm from the end & horizontal distance between insulators 1220mm bent at angle of 60 degree keeping base 305mm and the total vertical height ofV cross arm as 460mm, and fixed on pole with MS clamp of 80x10 mm, nut bolts, washers complete as per specification no. OH-PL/VCA |
| 971 | Supplying and erecting 75x40 x6mm with 4.4mm thick web and 7.3mm thick flangechannel (top pin) with clamp of suitable length so as to maintain vertical clearance of 1065mm for 11kV, 1320mm for 22kV between insulators for erection of top pin insulators complete as per specification no. OH-PL/VCA |
| 972 | Supplying and erecting bracket for guarding of HT OH Line, madefrom channel iron 1600mm in lengthand 75x40x6mm. erected on pole complete as per specification no. OH-PL/VCA |
| 973 | Supplying & erecting single pole cut point channel set of for 11kV HT OH line two channel of size 100x50x6mm 1.6m long having stud angle of size 50x50x6mm 1.5m long with necessary clamps, nut bolts etc. complete as per drawing. |
| 974 | Supplying and erecting ACSR conductor of size 6/1-2.59 mm complete. (Weasel) (127.7 kg/km)as per specification No. OH-CON/ACSR |
| 975 | Supplying and erecting porcelain disc type insulator 45KN with necessary hardware suitable for 11kV line, complete as per specification no. OH-INS/DI |
| 976 | Supplying and erecting porcelain pin type insulator with GI pin suitable for 11kV line, complete asper specification no. OH-INS/PN |
| 977 | Supplying and erecting G.I. stay set for poles, including loop insulators at inaccessible height with anchor plate 300x300x6mm., strainingscrews, G.l. stay wire 7/10 SWG, G.l. stay rod 20mmx1.8m length and pole clamps duly erected in provided cement concrete foundation complete. |
| 978 | Supplying and erecting guarding lace for HT OH line with 8SWG G.l. wire to protect the HT OH line with binding wire of 20SWG G.l. wire for 75mm section on either side. |
| 979 | Providing earthing with galvanizediron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. covercomplete with all materials, testing & recording the results asper specification no. EA-EP |
| 980 | Supplying, installation and testing of maintenance free earthing comprising of Electrode of 17.2 mm diameterLow Carbon Steel with 250 micronmolecular copper bonded earthing rod ofLength 3malong with 25 kg Carbonbased environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete, and recording the results Specification no. EA-MOBI |
| 981 | Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clampsfixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. |
| 982 | Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete. |
| 983 | Providing and back filling ground enhancing compound 25 kg bag complete. |
| 984 | Supplying, installing, testing & commissioning compact substation with 3 phase, 11/0.433 kV, 50 Hz., 500 kVA, Mineral Oil immersed Copper wound, without gas cushioning ,hermetically Sealed transformer having indoor type transformer bushings, with HT side (incoming side) load break switch of appropriate capacity and LT side (outgoing side) MCCBs (4 pole) of appropriate capacity , with out inbuilt metering cubical, using type A winding insulation (kraft paper),standard accessories complete with test certificate with losses below 1510 Watts at 50% load, 4300Wattsat 100% load for transformer, as per IS:1180 (part 1) : 2014 , with necessary permissions of Electrical Inspectors per specification no SS- TR-SL. (Without Metering Cubical) [Base Rate -2185158-35000 = 2150158 +5% = 2257665.90/-] |
| 985 | Supplying and erecting11 kV outdoor type gang operated airbreak,triple pole switch 400 A capacitywith3postpin type insulator per phase, mounted in horizontalor vertical position with necessary channels on providedcrossarmwithadequate length of \"C\" class G.l. pipe for operating handle erectedonextendedsquareshaft. Theoperatinghandle provided with lock and key at suitable heightfrom ground level with necessary clamp. |
| 986 | Supplying & erecting barbed wire two ply with 12 SWG ply and 12 SWG barb with a gap between two bars of 75 mm. firmly fixed on provided angle supports with necessary materials complete. (6.044 meters/kg.). |
| 987 | Providingpair ofdulytestedrubber hand glovesas per IS :47705suitable forworking up to 22 kV supply complete. |
| 988 | Making trench in Hard murum/Tar roadhaving 0.75 m depth and minimum0.3mtr width as per IS for laying provided cables up tovoltage level1.1Kv cable complete as per specification No. CW-EXN-CTR |
| 989 | Making cement concrete foundation including excavation(60x 60 x 150) cm deep in 1:3:6 cement concrete 20 x 25 mm stone metal, (45x 45x 45) cm /45 cm dia. x 45 cm height plinth duly plastered,with necessary curing and finishing complete. (above 6 m to 9 m poles) |
| 990 | Making cement concrete foundation including excavation(60x 60x 150) cm deep in 1:3:6 cement concrete, (20 to 25) mm stone metalwith necessary curing and finishing complete.(for stay). |
| 991 | Making cement concretefoundationin 1:3:6 cement concrete,(20 to 25) mm. stone metal duly plastered with necessary curing forcomplete. (pole muffing or any other purpose). |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail