| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. (Group B) |
| 2 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (i) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 3 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (ii) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 4 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. 3 x 1.5 sq. mm |
| 5 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. 3 x 4 sq. mm |
| 6 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. ( 20 mm) |
| 7 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 8 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required. |
| 9 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required |
| 10 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlet and 2 Nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). |
| 11 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. |
| 12 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required. (For 10 way, Double door SPN MCBDB) |
| 13 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (2 + 8 way, Double door) |
| 14 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Single pole ) |
| 15 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Single pole and neutral ) |
| 16 | Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 17 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 18 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required( 50 mm dia ) |
| 19 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 20 | Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. |
| 21 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) |
| 22 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) |
| 23 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 24 | Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. |
| 25 | Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. |
| 26 | Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum conductor cable of 1.1 KV grade as required. (2 X 25 sq. mm (22mm) |
| 27 | Supply, installation, testing and commissioning of 20 watt LED battan fittings complete with all accessories and LED tube directly on ceiling/ wallincluding connection with 1.5 sq. mm FRLS PVC insulated copperconductor single core cable etc as required. |
| 28 | Supply and fixing of Decorative, wall mounting, brushed nickel finish fixture with Opal Glass diffuser suitable with 9 W LED lamp B22 baseHavells make or its equivalent to CG/Bajaj/Philips/Surya |
| 29 | Providing and fixing of 1200 mm sweep ceiling fan , including wiring the down rods of standard length (upto 30 cm) including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 30 | Supplying,Installation, testing and commissioning of heavy duty exhaust fan, metalic body 230V,300 mmsweep,single phase including making the hole to suit the size of the above fan, making good the damage i/c P/F louver and shutter complete with frame for exhaust fan of size connections,testing and commissioning etc as required. |
| 31 | Supplying installation testing and commissioning of wall fan 230V,400 mmsingle phase on the wall including connection testing and commissioning etc as required. |
| 32 | Supply and fixing of 10 Watt Mirror LED battan surface mounted with integrated electronic driver in ceiling/surface complete with all accessories including connections etc. as required. |
| 33 | Providing and fixing of 12 watt surface mounted LED fitting square directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 34 | Supplying and installation of LED street light luminaire, 30 Watt Energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with acrylic cover as diffuser with IP66 protection including the G.I. pipe (medium class) bracket 32 mm dia X 1.5 metres long including bending the pipe to the required shape fitting including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 35 | SITC of various sizes water protected outdoor (Water proof)huttype compartmentalized type double door cubical panelboth side opening havingdepth up to 450 mmsuitable for 415 Volt, 3 phases, 50 Hz made out of 2mm thick CRCA sheet with required hardware duly painted with powder coated .Panel having separate detachable gland plate, angle iron base frame made out of 50mmx50mmx5mm angle iron of suitable size of the feeder pillar (minimum height 60cm), hinged door, both side opening with locking arrangement, earth bar/stud, led pilot light for phase indicator (R,Y,B) on top, 200A/415V 4 strip aluminum bus bar duly PVC sleeved, connection inter–connection with 25% extra current carrying capacity busbars to MCCBs spreader links and with solid copper conductor cable 10 sqmm/ solid aluminium rodfor connection toMCBs and heavy duty connectors of required current carrying capacity to be fixed back side including incoming/Outgoing cables connection for three and single phaseMCBs where as required, testing on loadand marking of location for incoming and out going distribution i/c grouting the legs in existing floor with 1:3:6 cement concrete foundation and dsimantling the existing panel, incoming/outgoing cable connections etc complete as required i/c dismentling the existing feeder pillar and UG cable. (Panel should beas per design &drawing approved by Engg in charge).LED light min 5 watt with on/off switch to be provided in the panel. |
| 36 | Providing and fixing of 100 Amp, 15 to 18 KA breaking capacity 415 Volt 50 Hz three pole With Thermal Magnetic Trip Unit (TMD)in existing feeder pillar (Item No 35) including drilling holes in cubicle panel, making connections, etc. as required. |
| 37 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (A) Double pole. |
| 38 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (A)Triple pole |
| 39 | Supplying and laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of alluminume armoured 3.5 x 35 sqmm direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. |
| 40 | Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of alluminume armoured 3.5 x 35 sqmm in the existing RCC/ HUME/ METAL pipe as required. |
| 41 | Supplying and laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of alluminume armoured 2 x 25 sqmm direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. |
| 42 | Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of alluminume armoured 2 x 25 sqmm in the existing RCC/ HUME/ METAL pipe as required. |
| 43 | Supplying, Installation, testing & Commissioning of 2 KW capacity Off Grid hybrid inverter solar system with 8 hours battery back-up (Life of battery 5 Yrs min), using 350 Wp, Polycrystalline silicon PV modules mounted on fixed axis structure fabricated from hot dip galvanized steel on suitable size concrete base foundation, including inverters, all electrical connection should be made with suitable size of copper conductor cable as required, all specification should confirms to MNRE specifications. |
| 44 | Supplying ,installation,testing and commisioning of solar water heating system including electrical heater backup ,make up water tank but without plumbing work .100 litres capacityas required and directed by engg incharge. |
| 45 | Structural steel work rivated bolted or welded in built up section , trucesse and frame work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 46 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, i/c all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fiitings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall (i)25 mm nominal outer dia pipes |
| 47 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, i/c all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fiitings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall (ii)20 mm nominal outer dia pipes |
| 48 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : (i)25 mm nominal bore |
| 49 | Providing and fixing brass stop cock of approved quality :(i)20 mm nominal bore |
| 50 | Providing and fixing brass bib cock of approved quality : (i)20 mm nominal bore |
| 51 | Providing and fixing gun metal non-return valve of approved quality (screwed end) :(i)25 mm nominal bore (Horizontal) |
| 52 | Providing and fixing GI pipes complete with GI fittings and clamps, i/c cutting and making good the walls etc :(i)20 mm nominal bore |
| 53 | Making connection of GI distribution branch with GI main of following sizes by providing and fixing tee, including cutting and threading the etc complete :(i)25 to 40 mm nominal bore |
| 54 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (500 ltr x 1nos = 500 ltr tank) |