| 1 | Earthwork in cutting to form road section in correct profile including removal of spoils not exceeding initial lead of 50 m and initial lift of 1.5 m. iii) In mixed hard soil (i.e. hard moorum and soil containing laterite and boulders which do not require blasting.) |
| 2 | Earth Work in excavation of foundation trenches or drains in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing. Spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches leveling dressing and ramming the bottom. Bailing out water as required complete. (a) Depth of excavation not exceeding 1500 mm. |
| 3 | Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150mm. Including watering and ramming etc. layer by layer complete. (a) with earth obtained from excavation of foundation. |
| 4 | Cement concrete with graded stone ballast (40 mm. size) excluding shuttering. In ground floor (B) with N.B. variety stone metal (b) 1:3:6 proportion. |
| 5 | Ordinary cement concrete (mix 1:1.5:3) with graded stone chips with (20 mm normal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes(ii) River Bazree. |
| 6 | Hire and labour charges for shuttering with centering and necessary staging upto 4.0m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting,fixing and striking out after completion of work (up to roof of ground floor) (a) 25 mm to 30mm thick wooden shuttering as per decision and direction of the EIC. |
| 7 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc. initial straightening and removal of loose rust (if necessary), cutting to requisite length hooking and bending to correct shape, placing in proper position and binding with 16-gauge black annealed wire at every inter-section, complete as per drawing and direction. (a) For works in foundation, basement and up to roof of ground floor/up to 4m) (i)Tor steel/Mild steel III. Others manufacturers not specified |
| 8 | 25 mm thick damp proof course with cement concrete with stone chips (1:1.5:3) (with graded stone aggregate 10mm nominal size) and admixture of water proofing compound as per manufacture\"s specification followed by two coat of polymer based paint (1st coat after 4 to 5 days of concrete laying and 2nd coat just before brick masonary work) as directed. (Cost of water proofing compond and polymer based paint to be paid seprately). (Chequering not required over concrete or painted surface). |
| 9 | Extra rate for using wate proofing and plastering admixtuere @ 0.2% by weight of cement (or at manufacture\"s specified rate) for concrete of various grade. |
| 10 | Brick work with Ist class bricks in cement ‘‘(1:6 (b) In Super structure. Ground floor. |
| 11 | l25mm Brick work withIst class bricks in cement mortar(1:3)(b) Ground floor. |
| 12 | Rubble masonary in cement (1:6) with hard dressed stones from approved quaries and clean coarse and washed sand including carriage of all materials to site (a) In road & Jhora works. |
| 13 | Supplying, fitting & fixing 1st quality Ceramic tiles in wall and floors to match with the existing work and 4nos of key stone(10mm)fixed with aralidiet at the back of each tile and finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughining of concrete surface if nececcary orby synthetic adhesive and grout material etc(B)FLOORWith Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. (a)Area of each tile aboveo 0.09sqm(ii) Other than Coloured decorative including white. |
| 14 | Supplying, fitting & fixing 1st quality Ceramic tiles in wall and floors to match with the existing work and 4nos of key stone(10mm)fixed with aralidiet at the back of each tile and finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughining of concrete surface if nececcary orby synthetic adhesive and grout material etc(B)WALLwith sand cement mortar(1:3) 15mm thick and 2mm thick cement slurry at back side of tiles using [email protected]/sqm and joint filling using white cement slurry @0.20kg/sq m(a)Area of each tile up to 0.09sqm(ii) Other than Coloured decorative including white. |
| 15 | Plaster (to wall ,floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joint including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor) (c) 15 mm thick with 1:6 cement mortar |
| 16 | Plaster (to wall ,floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course scaffolding/staging where necessary (Ground floor) (c) 10 mm thick with 1:4 cement mortar |
| 17 | Neat cement penning about 1.5 mm thick in wall dado, window sills, f1oors, drain etc. Note: Cement 0.152 cum per 100 sqm |
| 18 | Supplying solid flush type doors of deluxe decorative (both side) quality, conforming to I:S 2202 timber frame consisting of top and bottom rail and side styles of well-seasoned timber 65mm wide each and the entire frame fitted with 27.5mm wide battens places both ways in order to made the door of solid coreand internal lipping with teak, mahogony or rose wood approved decorative veneers using phenol formaldehydeas glue etc. complete, including fitting, fixing the shutters in position but excluding the cost of hinges and other fittings in ground floor:(a) 35mm thick shutters (single leaf) |
| 19 | Supplying, fitting and fixing clear visioned, Insulated Double Glazed two track sliding Aluminium window (U- value < 3.2W/m 2 K) made up with 6 mm thick toughened glass (wt > 15kg/m 2) with 12 mm air gap in between, containing perforated Al/ stricture foamspacer filled with moisture absorbent desiccant at all sides duly sealed with primary sealant (polyisobutylene) and affixed inside multi cellular/ multi chember profiles of required section made of Alluminium alloy extensions conforming to IS:733-1983 and IS:1285 - 2002 annodised/powder coated with (required film thickness and specified colour /natural) matt finished conforming to IS: 1868-2006/ IS: 13871-2002 measured as per IS:6012-1992, and sealed appropriately with secondary (polysulphide/silicon) sealant all junctions complete in all respect as per direction and satisfaction of Engineer- in-Charge including all incidental charges. (Payment shall be made on finished size of Aluminium window including frame.) |
| 20 | Supplying, fitting and fixing fibre reinforced polymer (FRP) Composite door frame as per approved section with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to safisfy IS: 4020 door testing performance criteria.(ii) 66mm x 70mm |
| 21 | Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite stricture as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria. In ground floor (ii) 25 mm thick |
| 22 | Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732- 1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In Charge. (Payment will be made on finished length of the work). f) Casement window ( 34 mm Depth series)(i) Outer Frame |
| 23 | Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732- 1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In Charge. (Payment will be made on finished length of the work). f) Casement window ( 34 mm Depth series) (ii) Mullion |
| 24 | Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732- 1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In Charge. (Payment will be made on finished length of the work).Casement window ( 34 mm Depth series) (iii) Shutter |
| 25 | Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732- 1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In Charge. (Payment will be made on finished length of the work).Casement window ( 34 mm Depth series) (iv) Glazing clip |
| 26 | Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732- 1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In Charge. (Payment will be made on finished length of the work).Casement window ( 34 mm Depth series)(v) Cleat Angle (Non-annodized) |
| 27 | Supplying best Indian sheet glass panes set in putty and fitted and fixed with nails and putty complete. (In all floors for internal wall & up to 6m height for external wall) (ii) 4 mm thick |
| 28 | (a) M.S. or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.(i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr |
| 29 | Synthetic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer\"s specification) including cleaning and smoothing of surface. Two Coats. |
| 30 | Cement washing including cleaning and smoothening surface thoroughly (cement to be used @ 15 Kg./100 sq.m of surface for one coat and @25 kg./100 sq.m of surface for Two coats): External surface (Ground floor) (b) Two coats (on new works only). |
| 31 | Applying decorative cement based paint of approval quality after preparing the surface including scraping the same thoroughly (plastered or concrete surface) as per manufacturer’s specification in Ground floor: (iii) Two coats. |
| 32 | Anodised aluminium Aldrop/Sliding bolts of approved quality manufacturing from extruded section conforming to I.S. specification (I.S. 2681/66) fitted and fixed complete: (iv) 300mm x 19 mm dia bolt. |
| 33 | Iron butt hings of approved quality fitted and fixed with steel screws, with ISI mark. (viii) 100 mm x 75 mm x 3.50 mm |
| 34 | Add Extra 30% for Oxidised Fittings of item no.33 |
| 35 | Anodised aluminium barrel/tower/socket bolt (fully coveed) of approved quality manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screw. (viii) 225 mm long X 12 mm dia bolt. |
| 36 | Iron door handel of approved quality fitted and fixed complete 100 mm x 5 mm |
| 37 | M.S. structural works with hollow sections (square or rectangular shape) conforming to IS: 806-1968 & IS:1161-1998) connected to one another with bracket, guest, cleat as per design, drawing & direction of Engineer-in-Charge compete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814-2004, haulage, hoisting and cost of all M.S, Hollow section, all consumables such as electrodes, gas and hire charges of all tools and plants and labour required for execution and all incidental chages (such as electricity, labour insurance) etc. complete. Payment to be made on the basis of calculated weight of structural members of MS Holow Section as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a hight of erection 8 m. / 2nd floor level from the ground. Add 1.5% extra over the rate for each additional floor or 4m. beyond the initial 8 m. or part thereof. I) For roof truss works a) Span up to 12 Mtr. |
| 38 | Galvanised corrugated iron sheet work (excluding the supporting frame work) fitted and fixed with 10 mm. dia J or L hook-bolts, limpet and bitumen washers and putty complete with 150 mm. end lap and one corrugation minimum side lap. (payment to be made on area of finished work)(GCI sheet to be supplied by contractor) (i) In Roof:(b) With 0.63 mm thick sheet |
| 39 | Galvanised iron sheet ridging fitted with necessary bolts, screws, washers etc complete. (225mm end lapping) (A) 300 mm lapping each way (b) Whit 0.63 mm sheet |
| 40 | Construction Inspection pit of inside measurement 600mm X 600mm X up to 600mm (depth) with 250mm thick 1 St. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling, 15 mm thick (1:4) cement plaster to inside walls and out-side walls up to G.L. and 20 mm. thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1:5:3) with stone chips and necessary reinforcements up to 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole of cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials ii) With Bazree (N.B Variety) (Other than SAIL/TATA/RINL) |
| 41 | Construction of septic tank of different capacities as per approved drawing with 1 st class brick work in cement mortar (1:4) including two 560 mm dia R.C.C. manhole cover (heavy type) of approved make supplied fitted and fixed in the 100 mm thick RCC (1:1:5:3) top slab with necessary fittings 20 mm thick cement plaster (4:1) with neat cement finish to the internal surfaces and 15mm thick cement plaster (4:1) to outside wall up to 200mm below G.L floor finished with 25mm thick grey artificial stone over 100mm thick RCC (1:5:3) bottom slab including supplying, fitting and fixing all necessary specials, fittings, S.W. tees, C.I foot rest etc including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and refilling the sides of the tanks with earth removing, spoils filling of the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all cost of labour and materials. (iii) For 30 user, (B) with Bazree(N.B varity) |
| 42 | Construction of circular well 2.5 metre deep in all types of sandy soils with dry work up to 1.6 metre from the bottom having 150mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) up to 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face up to the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well up to G.L and 6mm thick cement plaster (1:4) on the top the R.C.C cover slab including filling bottom 1.00metre of inside of the well with brick metal (50mm to 63mm size) including R.C.C cover slab of 10mm thick with cement concrete (1:1:5:3) with stone chips with necessary reinforcement and shuttering cove (heavy duty) of approved make supplied, making necessary arrangements for pipe connection, excavation the excess earth from the premises as per direction complete in all costs of labour and materials. With 250mm thick dry brick work and 250mm thick cement brick work (6:1) and 1.00m inside did (Other than SAIL/TATA/RINL) |
| 43 | Supply of UPVC pipes (B-Type) & fittings conforming to I.S.13592-1992, (A) (i) Single Socketed 3 meter length (b)110 mm. |
| 44 | Supply of UPVC pipes (B-Type) & fittings conforming to I.S.13592-1992, (B) fitting (b)110/110 S trap |
| 45 | Supplying, fitting and fixing Orissa pattern water closet in white glazed vitreous china wire of approved make supplied, fitted and fixed in position complete excluding P or S trap. (i) 530mm X 4l0mm |
| 46 | Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black)- Multilayer (b) 1000 liter capacity. |
| 47 | Supplying, fitting and fixing 10 liters P.V.C. low- down cistern conforming to I.S. specification with P.V.C. fittings complete, C.I. brackets including two coats of painting to bracket etc. |
| 48 | Supplying, fitting and fixing GI pipes of TATAmake with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbow, nipple, long screw, reducing socket, reducing tee, short piece etc. fitted with holder bat clamps, including cutting pipes making threads, fitting, fixing etc. complete in all respect including cost of all necessary filming as required , jointing materials and two coats of painting with approved paint in any position above ground( Paymentwill be made on the centerline measurement of total pipeline including all specials. No seprate payment will be made for accessories, specials.) For Exposed work (ii) 15 mm dia. medium quality |
| 49 | Supplying, fitting and fixing bib cock or stop cock.(g)Supplying, fittin and fixingalloy iron with brass spindle bib cock/ stop cock of approved brand and make, spray painted and tested to 21 kg/sqcm.(i)15mm |
| 50 | Supplying, fitting and fixing pillar cock of approved make. a) (i) CP Pillar Cock - 15 mm. (Equivalent to Code No. 507 & Model -Tropical / Sumthing Special of ESSCO or similar brand). |
| 51 | Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materials (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete. A) UPVC Pipes: 75 mm. Dia. |
| 52 | Supply of High Density Poly -ethylene Pipe conforming to IS -4984-1985 (Dia) (PE-63) (B.) 10Kg/ Sq Cm(Dia)(Working Pressure) 15 mm |
| 53 | Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint. (ii) 550 mm X 400 mm size |
| 54 | Supplying, fitting and fixing pedestal of approved make for wash basin (white) |