| 1 | Notes:-(i) 50 percent nonperishable items of the work shall be deposited by the L1 bidder within 30 days after placing of work order.(ii) The critical path network shall be submitted by L1 bidder immediately after the acceptance of tender and approved by GE.(iii) The bidders must ensure to visit the site, check relevant documents and makes of materials required to be incorporated under the subject from concern Engineer-in-Charge.(iv) The unserviceable material obtained under the schedule of credit shall be handed over to the contractor by the Engineer-in-Charge on a proper gate pass.(v) In case of non-availability of any make mentioned under list of Makes, the L1 Bidder shall obtain non-availability / non-manufacturing certificate from the concern OEM / authorised dealers and submitted to Accepting Officer, the L1 bidder may be incorporated makes as approved by HQ CE SWC Jaipur / HQ CE BTZ in the works after prior approval of Accepting Officer.(vi) L1 Bidder shall produce E-way bill alongwith test certificate from OEM / manufacturer for costly items / major items of amount above Rs 50,000/- along with RAR’s and Final Bill.(vii) L1 Bidder shall be maintained an album containing Photos of all the material brought at site and each stage wise work progress and kept at site. Same shall be deposited in Engineer-in-Charge office after completion of work.(viii) Suffficient tradesman, Labours needs should be employed by the bidder on daily basis and as required by Engineer-in-Charge. (ix) Main Items and fixtures, base materials shall be from the same manufacturer.(x) The cost of all the above provisions shall be deemed to be included in the quoted rate of bidder, nothing extra shall be paid to the bidder. |
| 2 | M&L for preparation of old surface by complete removal of existing treatment of painted walls incl pillar ceiling etc. by mechanical equipment like electric wall sander with vaccum bag/water jet machine and applying acrylic wall putty of 1.5 mm thickness over existing surface to prepare the surface even and smooth and applying two coat of distemper with 1st quality distemper(ready mixed) having VOC content less than 50gms/liter, of approved manufacturer, of required shade and colour over A coat of alkali resistant primer compete by mechanical means as per manufacturers specifications and instructions andas directed by GE.Note:- 1.Primer,putty and Acrylic paint should be of same Make as approved by GE.2.removal of existing nails etc and repairing same with filling deemed to be included in quoted rates complete. |
| 3 | M&L for preparation of old surface of walleven and smooth and applying one coat of oil bound distemper with 1st quality distemper(ready mixed) having VOC content less than 50gms/liter, of approved manufacturer, of required shade and colour over a coat of alkali resistant primer compete, by mechanical means/Roller as per manufacturers specifications and instructions complete as directed by GE. |
| 4 | M&L for preparation of old surface by complete removal of existing treatment of painted Ceiling incl beamsby mechanical equipment like electric wall sander with vaccum bag/water jet machine and applying acrylic wall putty of 1 mm thickness over existing surface to prepare the surface even and smooth and applying two coat of distemper with 1st quality distemper(ready mixed) having VOC content less than 50gms/liter, of approved manufacturer, of required shade and colour over a coat of alkali resistant primer compete, by mechanical means as per manufacturers specifications and instructions complete as directed by GE.Note:- Primer,putty and Acrylic paint should be of same Make as approved by GE.2.removal of existing nails etc and repairing same with filling deemed to be included in quoted rates complete. |
| 5 | M&L for preparation of old surface of ceilingeven and smooth and applying one coat of oil bound distemper with 1st quality distemper(ready mixed) having VOC content less than 50gms/liter, of approved manufacturer, of required shade and colour over a coat of alkali resistant primer compete, by mechanical means/Roller as per manufacturers specifications and instructions complete as directed by GE. |
| 6 | M&L for preparation of old surface by complete removal of existing treatment of painted walls incl pillarsby mechanical equipment like electric wall sander with vaccum bag/water jet machine and applying minimum two caots of 100 % premium acrylic emulsion paint having VOC less than 50 gm/liter and UV resistance as per IS 15489:2004, alkaili & fungal resistance, dirt resistance exterior paint of required shade (compaly Depot tinted) with silicon additives @ 1.43 liters/10Sqm over and including priming coat of exterior primer applied @0.90 Liter/10 sqm over wall surface complete, by mechanical means as per manufacturer\"s instructions and all as specified and as directed by GE.Note:- 1. Primer,putty and Acrylic paint should be of same Make as approved by GE.2. Removal of existing nails etc and repairing same with filling deemed to be included in quoted rates complete. |
| 7 | M&L for preparation the old painted wooden surfaces of any description over 10 cm width or girthand applying one coat of synthetic enamel paint complete all as specified and as directed. |
| 8 | M&L for preparation old painted steel surface of any description n. exc. 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed by Engineer-In-Charge. Note:- Doors should be checked and easened form smooth fuctioning and quoted rates deemed to be included in rates nothing extra shall be paid. |
| 9 | S&F as in replacementStainless steel wire cloth 0.36mm nominal dia of wire and average width of aperature 1.40mm and fixed with stainless steel wire staples. |
| 10 | S&F as in replacement prelaminated partical board 19/20mm medium density ,prelaminated with one side with decorative choicelaqmination and other side balancingwith white laminationfixed with screws as in shelves to kitchen almirah and cub board fixed in replacement. SS handles , piano hinges and teak wood lipping deemed to be included in quoted rates complete all as specified and as directed.Make:- Century/greenply/kitply Note:- Quoted rates deemed to be inclusive of aluminum handles to facilitate the functioning of cup boards . |
| 11 | S&F as in replacement 3 mm thick sheet glass, ordinary quality and glazing with oil putty in square not execeeding 0.5 sqm in each pane for metal frames complete all as specified. |
| 12 | Taking down cement plaster or cement lime plaster on stone surface/brick surfaces of walls including raking out joints hacking for key scrubbing down with water etc and M&L for rendering 10 mm thick in CM 1:6 onfair faces of brick work or concrete surfacesfinished fair and even including prepration of new plasteredsurface of wall including pillars and applying acrylic wall putty of 1.5 mm thickness over existing surface to prepare the surface even and smooth and applying two coat of distemper with 1st quality distemper(ready mixed) of approved manufacturer, of required shade and colour over a coat of alkali resistant primer complete, by mechanical means as per manufacturers specifications and instructions complete as directed by GE.Note:- 1.Primer,putty and Acrylic paint should be of same Make as approved by GE.2.removal of existing nails etc and repairing same with filling deemed to be included in quoted rates complete. |
| 13 | Taking down cement plaster or cement lime plaster on stone surface/brick surfaces of walls including raking out joints hacking for key scrubbing down with water etc andM&L for rendering 15 mm thick in CM 1:4 on fair faces of brick work or concrete surfacesfinished fair and even includingprepration of newsurface of wall and aplying minimum two caots of 100 % premium acrylic emulsion paint having VOC less than 50 gm/liter and UV resistance as per IS 15489:2004, alkaili & fungal resistance, dirt resistance exterior paint of required shade (compaly Depot tinted) with silicon additives @ 1.43 liters/10Sqm over and including priming coat of exterior primer applied @0.90 Liter/10 sqm over wall surface complete, by mechanical means as per manufacturer\"s instructions and all as specified and as directed by GE.Note:- Primer,putty and Acrylic paint should be of same Make as approved by GE.2.removal of existing nails etc and repairing same with filling deemed to be included in quoted rates complete. |
| 14 | Taking down cement plaster or cement lime plaster on concrete surfaces of ceiling including raking out joints hacking for key scrubbing down with water etc and M&L for rendering 5mm thick on fair faces ofconcrete surfaces as in ceiling in cement mortar 1:3,even and smooth without using extra cement as on ceiling includingpreparation of new surface ofceiling incl Beams and applying acrylic wall putty of 1.5 mm thickness over new surface to prepare the surface even and smooth and applying two coat of distemper with 1st quality distemper(ready mixed) having VOC content less than 50gms/liter, of approved manufacturer, of required shade and colour over a coat of alkali resistant primer compete, by mechanical means as per manufacturers specifications and instructions complete as directed by GE.Note:- Primer,putty and Acrylic paint should be of same Make as approved by GE.2.removal of existing nails etc and repairing same with filling deemed to be included in quoted rates complete. |
| 15 | S & F as in replacement glass corner shelfof size 300mm with5.5 mm thick glass andsteelness steel clip and steelness steel railing allround the shelffixed complete as manufacturers instructions complete all as specified and directed by engineer in charge .Make:- Jaquar/Kohler/Grohe. |
| 16 | Disconnecting existing tanks, setting aside (or lowering if required) for repairs cleaning etc andhoisting if required reconnecting and refixing in position after cleaning and removing all scale and dirtetc from tanks and from mouths of circulating pipes etc complete (capacity of tanks 500 liters to 2000 liters ) complete all as specified and as directed |
| 17 | S&F as in replacement 15mm bore angle valve cast copper alloy fancy type chromium plated with long shank and cup and screwed for iron pipefixed complete all as specified and directed. |
| 18 | S&F in replacement Aluminium snake bead with bush duly fitted with screws with length equal to door width as specified and directed by Engr-in-Charge |
| 19 | S&F in replacement of 7\" stainless steelmortice door lock handle set with 2 keys suitable for Left and right side complete all as specified and directedMake:- Godrej/Dorset/Europa |
| 20 | M&L for non skid ceramic coloured tiles 7 to 8mm thick (square/rectangular)area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in floors,setintile adhesive confirming to IS-15477-2019type 1 and thickness as per manufacturer instruction of approved makeincluding rendering 10mm thick screed bed in cement & sand mortar (1:4) inc andluding dismantling existing floor,hearth tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-charge.Note:-1. Joints of tiles shall be filled with appropriate white cement base grouting compound to match the colour of tiles complete quoted rates deemd to be included it nothing extra shall be paid on this account. |
| 21 | M&L for glazed Vitrifiedtiles (coloured) 600mmx1200mm8-9 mm thickon vertical surfaces , setintile adhesive confirming to IS-15477-2019type 2 and thickness as per manufacturer instruction of approved make including rendering 10mm thick screed bed in cement & sand mortar (1:4) and including dismantling existing wall tiling with cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-charge. Note:-1.Joints of tiles shall be filled with appropriate white cement base grouting compound to match the colour of tiles complete quoted rates deemd to be included it nothing extra shall be paid on this account.2.Corners of floor and wall tiles in bathroom area shall be filled with white Silicon Gel quoted rates deemd to be included itand nothing extrashall be paid on this account 3. Tiles shall be fixed with minium 3 mm spacers filled with epopxy resin colour as approved by engineer-In Charge of Make:- Atul/BASF/AdityaBirla/3M. |
| 22 | Water proofing treatment to sunken slab and adjjoining vertical surfaces as specified under :-(a) Demolition of cement concrete in sunken portion.(b) Preparation sunken surfaces by cleaning of and removal of loose concrete(c) Filling cracks with polymer modified mortar using Dr. Fixit Pidicrete URP or equivalent in Forsoc and other approved make(d) Applying 2 coats of Dr. Fixit Bath seal WPC in suken areas and laying a protective plaster in 10mm thickness in cement mortar (1:3) admixed with Dr. Fixit Pidicrete LW + @ 220ML per bag of cement(e) Applying mix ofofDR FIXIT PIDICRETE URP in the ratio 1:1:5 on floor and vertical surface of sunken portion as per manufacturers instructions complete(f) Filling with P:C:C 1:5:10 Type-E2using 40 mm graded brick aggregate complete all as specified and directed by Engineer-in-chargeNote: The plan area of floor shall be considered for payment. |
| 23 | S&F as in replacement of 20 mm nominal bore diaCPVC pipes SDR 11 & Plain/Brass fittings(Elbow,Tee,MTA,FTA,Union)CPVC SDR 11 fittings onwalls/ceiling or laying infloors including plug at opening or points for fiting and fixtures and powder coated clamps for fixing in wallscomplete all asall fittings and fixed and taking down of existing15 mm bore pipe of any descripttion complete to walls and ceilings or laid in floors complete all as specified and directed by Engineer-in-charge.Note:- Pipe should be fixed on wall as per DRG NO:- BTD-916 as approved by GE quoted rates deemed to be included nothing extra shall be paid . . |
| 24 | S&F as in replacement of25 mm nominal bore diaand laying ofCPVC pipes SDR 11 & Plain/Brass(Elbow,Tee,MTA,FTA,Union,Tank Adapter,)CPVC SDR 11 fittingsonwalls/ceiling or laying infloors including plug at opening or points for fiting and fixtures and powder coated clamps for fixing in wallscomplete all asall fittings and fixed and taking down of existing20 mm bore pipe of any descripttion complete to walls and ceilings or laid in floors complete all as specified and directed by Engineer-in-charge. Note:- Pipe should be fixed on wall as per DRG NO:- BTD-916 as approved by GE quoted rates deemed to be included nothing extra shall be paid . . |
| 25 | S&F Vitrified Ceramic tiles 8-9mm thick (square/rectangular) double charged , area of each tiles n exc. 0.36Sqm, in floors and as in skirting of 100mmheight etc laid with minimum 3 mm spacer filled with Epoxy Resin of make :- Atul,BASF,Aditya birla,3M set with Type -1 cement base adhesive As Per IS-15477-2019including rendering 10mm thick screed bed in cement & sand mortar (1:4) complete as specified by Manufacturer complete. all as specified and as directed By Engineer-In-Charge. |
| 26 | Supply& fixing in replacementvitreous china premium / 1st quality wash down water closet wall hung (with dual hung cistern) EWC white/ivory/off white (closedpattern) incl all necessary accessories like rag bolts / gel gasket etc incl flushing cistern , CP jet sprayand also included all the necessary fillting of PVC pipe up to 1st MH of bldg complete all as specified and directed.Make :-Parryware verve AM C022N and C0762 or equivalent cat part No. of make as specified in Appendix \"B\". |
| 27 | S&F in replacement looking mirror of any size 5 mm thick fixed with minimum4 nos SS brackets including rounding the edge of Mirror complete all as specified and as directed By Engineer-In-Charge. |
| 28 | S&F as in repair 110mm bore PVC (SWR) pipes as Per IS 13592single socketed, in any length with/wthout rubber ring joints, fixed to walls includingdismantling existing CI/PVC pipe alongwith fittings of 75/100mm dia,below or above GL, laid in floors or fixed to walls jointed in cement mortar. Note : Quoted rates deemd to be inclusive of coupler,reducer,Bends, lip seal fittings for SWR as per IS 14735 Note:- Pipe should be fixed with hot dip galvanizedclamps on wall as per DRG NO:- BTD-916 as approved by GE quoted rates deemed to be included nothing extra shall be paid . . |
| 29 | S&F PVC (SWR) bend any radius 110 mm bore as Per IS 14735 complete all as specified and as directed |
| 30 | S&F as in repair 75 mm bore PVC (SWR) pipesPer IS 13592single socketed, in any length with rubber ring joints, fixed to walls after Dismantling CI/PVC pipe alongwith fittings of 75/100mm dia,below or above GL, laid in floors or fixed to walls jointed in cement mortar Note : Quoted rates deemd to be inclusive of coupler,reducer,Bends fittings for SWR as per IS 14735 Note:- Pipe should be fixed with hot dip galvanizedclamps on wall as per DRG NO:- BTD-916 as approved by GE quoted rates deemed to be included nothing extra shall be paid . . |
| 31 | S&F PVC (SWR) bend any radius 75 mm bore with owl accessas Per IS 14735 complete all as specified and directed |
| 32 | Supply and fixing in repairs PVC (SWR) junction single, (Single T) equal or unequal bore 110 mm provided with owl access door Per IS 14735 complete all as specified and as directed |
| 33 | S&F PVC (SWR)75 mm floor trap, plain with CP Lock & Hole / Lock & Frame type grating including jointing with solvent cement complete all as specified and as directed |
| 34 | S&F in Replacement of PVC(SWR)vent cowl 75 mm inclusive of reducer socket complete all as specified and as directed |
| 35 | S&F35mm thick Flush Shutter ofand fixed with wooden finish 1mm thick laminated Mica sheet as approved by Engineer-In-Charge including 3 nos 100 mm SS butt hinges and 1 nos ss tower bolt , 1 nos magic eye, 1 Nos 7\"\" mortice lock and all edges covered with teak wood 5 mm thick lipping including 2 coat of synthetic enamel paint over a coat of primer complete all as specified including taking down existing wooden shutter from chowkhat and removing same to the store of Engineer-In-Charge. Note:- taking Down Existing old unserviceable shutter deemed to be included in quoted rates nothing extra shall be paid aaaaand contractor shall deposit the same to Engineer-In-Charge store before claiming for payment. |
| 36 | S&Fsecond class hard wood, glazed and skelleton shutters 35mm thick, open rebated and prepared to receive glass, gauze, etcwithout sash bar, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing gauze etc, size of members as directedsupplied and fitted to chowkats including two coat of synthetic enamel paint over a coat of pink primer including taking down existing wooden shutter from chowkhat and removing same to the store of Engineer-In-Charge.complete all as specified and directed.Note :- quoted rates deemed to be inclusive of 2 nos Aluminiumhandles150mm , 1 nos 200 mm aluminium tower bolts and repairing old butt hinge with welding if required. |
| 37 | Taking down carefully or drawn out from conduit, existing copper / aluminium point wiring for light, fan, bell, socket, power point etc complete including fixture and fittings such as switches, sockets, ceiling rose, pendent holder, light fittings, top sheet covers, fan regulators, MCB, DB, lamp, earth plug etc (excluding MS sunken boxes) and making good the disturbed surfaces of wall/ceiling complete all as specified and as directed by Engineer-in-charge. Note : Taking down of serviceable fittings shall be measured and paid separately. |
| 38 | M&L for point wiring complete with 1.5 sqmm (nominal cross sectional area) FRLSH PVC insulated multistandard unsheathed copper conductor cable with colour coding drawn in open conduit or existing concealed conduit in existing sunken box and covered with new 3mm thick bakelite plastic laminated sheet top cover fixed flush with wall using brass screws & cup washers including cutting chases in wall for conduits and making good the disturbed surfaces of wall and including 1.5 sqmm PVC insulated unshethed multistandard copper conductor wire as earth continuity to common earth and connecting to earth dolly for one light point, fan point, bell point controlled by one switch complete all as specifiedand directed by Engineer-in- charge. |
| 39 | All as per serial item No. 37 here-in-before but for One light point controlled by Two 2- way switches. |
| 40 | All as per Srl item No. 37 above, but wiring with cable of cross sectional area 2.5 Sqmm (nominal area) multi-stranded copper conductor FRLSH, PVC sheathed cable 1100 Volts shade for one switch socket combination 6 pin, 5/15 Amps on independent board including 2.5 Sqmm PVC insulated multistranded unsheathed copper conductor wire as earth continuity to common earth dolly. |
| 41 | All as per serial item No. 38 here-in-before but for One 3 pin 5 Amp socket outlet one light point controlled by one switch on the same board with other switches. |
| 42 | All as per serial item No. 38 here-in-before but for One 3 pin 5 Amp socket outlet one light point controlled by one switch on independent board. |
| 43 | S&Fswitch piano flush button 5 Amps single pole, one way complete all as specified and directed by Engineer-in-charge. |
| 44 | S&Fswitch piano flush button 5 Amps single pole, two way complete all as specified and directed by Engineer-in-charge. |
| 45 | S&Fsocket outlet 3/5 pin, 5 Amps 240 volts, flush type complete all as specified and directed by Engineer-in-charge. |
| 46 | S&Fbell push, flush type, 5 Amp, 230 Volts grade complete all as specified and directed by Engineer-in-charge. |
| 47 | S&Fswitch socket combination 5 pin, 5/6 Amps, 240 volts, flush type complete all as specified and directed by Engineer-in-charge. |
| 48 | S&Fswitch socket combination 5 pin, 5/15 Amps, 230 volts, flush type complete all as specified and directed by Engineer-in-charge. |
| 49 | S&F ceiling rose surface bakelite 65mmx50mm with two or three terminal complete all as specified and directed by Engineer-in-charge. |
| 50 | S&FLamp holder, insulated body with back plate etc complete all as specified and as directed by Engineer-in-Charge. |
| 51 | S&Felectric bell (ding - dong), AC, 230 Volts, Single pole & connecting up complete all as specified and directed by Engineer-in-charge. |
| 52 | S&Felectronic fan regulator suitable for ceiling fan 1200mm/1400mm sweep, socket size, rotary type complete all as specified and directed by Engineer-in-charge. |
| 53 | S&F as in replacement sheet metal plug & socket DB, SP, with a two pin and earth plug with socket,230 Volts with & including one MCB SP ‘C’ Curve 10 kA, 20 Amps complete all as specified and directed by Engineer-in-charge. |
| 54 | S&F as in replacement Sub main wiring complete with 2 single core 6 Sqmm (Nominal area) multi stranded copper conductor PVC insulatedunsheathed cable FRLSH drawn in and including heavy duty PVC conduit ISI marked not less than 25mm dia concealed including single core multistranded copper conductor 6 Sqmm size cable as earth continuity wire drawn in same conduit complete all as specified and directed by Engineer-in- charge Note :Two runs of 6 Sqmm single core cable and one run of 6 sqmm copper wire earth continuty conductor and conduit with fittingsshall be measured as one length. |