Ancillary Work At Madarat Community Hall Under Baruipur Ps- 1 COMMUNITY HALL 2 Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in gound floor as per relevant IS codes. a) Pakur Variety 3 i) In Ground floor 4 ii) In First floor 5 Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor).c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work 6 ii) In Ground floor 7 iii) In First floor 8 Reinforcement for reinforced concrete work inall sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. 9 i) In Ground floor 10 ii) In First floor 11 Brick work with 1st class bricks in cement mortar (1:6) 12 (a) In foundation and plinth 13 i) In superstructure, ground floor 14 ii) In First floor 15 iii) In Second floor 16 125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in Firstfloor. 17 i) In Ground floor 18 ii) In First floor 19 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/stagingwhere necessary (Ground floor).[Excluding cost of chipping over concrete surface] 20 (i) With 1:6 cement mortar (b) 20 mm thick plaster 21 i) In Ground floor 22 ii) In First floor 23 (i) With 1:6 cement mortar (b) 15 mm thick plaster 24 i) In Ground floor 25 ii) In First floor 26 (ii) With 1:4 cement mortar (c) 10 mm thick plaster 27 i) In Ground floor 28 ii) In First floor 29 Rendering the surface of walls and ceiling with white cement basedwall putty of approved make and brand(1.5mm thick) 30 Neat cement punning about 1.5 mm. thick in wall, dado, window, sills, floor, drain etc. NOTE : Cement 0.152 cu.m. per 100 sq.m. 31 Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals).(d) Sal : Local 32 i) In Ground floor 33 ii) In First floor 34 Panel shutters of door and window, as per design (each panel consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of hige and other fittings.In ground floor. (In case of non-supply of single plank, penal rate of reduction of 20% will be made)(iii) 35mm thick shutters with 19mm thick panel of size 30to 45 Cm.(b) Sishu,Gamar, Champ,Badam,Bhola, Mogra, Hallak. 35 i) In Ground floor 36 ii) In First floor 37 Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately).a) 40 mm. x 6mm x 250 mm. long 38 Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark.(vii) 100mm. X 58mm. X 1.90mm. 39 i) Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting. (c) 300mm long. 40 Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws: viii) 225mm long x 12mm dia. bolt. 41 (a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. a) weight 10 kg to 16 kg. / m2 42 i) In Ground floor 43 ii) In First floor 44 Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing.(b) Openable steel windows as per IS sizes with side hung shuttersand horizotal glazing bars. 45 Supplying best Indian sheet glass panes set in putty and fitted and fixed with nails and putty complete. (In all floors for internal wall & upto 6 m height for external wall).(i) 3 mm thick (weighing 7.4 kg/Sq.m) 46 Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugsset in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete. 47 Supplying, fitting and fixing fibre reinforced polymer (FRP) Composite door frame as per approved section with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to safisfy IS: 4020 door testing performance criteria.. (ii) 66mm x 90mm 48 Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria.In ground floor.(i) 32 mm thick 49 Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mm X 10 mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry back side of tiles using cement @ 2.91Kg./sqM or using polymerised adhesive (6 mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per sqM below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles / epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturers specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contrr]e). 50 i) In Ground floor 51 ii) In First floor 52 Supplying, fitting and fixing Marble Slab/tile of 15 to 18 mm thickness in floor, lobby, stair, landing & treads etc. over 20 mm (av.) thck base of Cement mortar (1:2) laid with white cement slurry @ 4.4 kg/Sq.m before placing marble & jointed with white cement slurry @ 2.0 kg/Sq.m with necessary pigments including grinding and Granite polishing as per direction of Engineering -in -Charge in Ground Floor. {White cement and Pigment to be supplied by the Agency].(ii) Area of each Slab/tile exceeding 0.3 sq.m. but not exceeding 0.6 sq.m. 53 i) In Ground floor 54 ii) In First floor 55 Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(B) Wall(b) Area of each tile above 0.09 Sq.m(i) Coloured decorative 56 i) In Ground floor 57 ii) In First floor 58 Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturers specification and as per direction of the EIC. (In Ground Floor).i) Water based interior grade Acrylic Primer 59 Acrylic Distemperto interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturers specification) including cleaning and smoothning of surface. Two Coats 60 Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured(matt finish) or smooth finishacrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturers specification and as per direction of the EIC. Two coat 61 Protective and Decorative Textured exterior high class matt finish paint of approved quality, composed of special Tharmoplastic Resin containing fine crystalline additives derive from Granite as per manufacturers specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost ofprimer.Two coat 62 Priming one coat on timber, plasteredsurface with synthetic enamel / oil bound primer of approved quality including smoothening surfaces by sand papering cte. 63 Priming one coat onsteel or other metal surface with synthetic enamel / oil bound primer of approved quality including smoothening surfaces by sand papering cte. 64 Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : 65 a) On timber or plastered surface: Two coals(with any shade except white). 66 b) On steel surface: Two coals(with any shade except white). 67 Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete.A) UPVCPipe(ii) 110 mm. Dia. 68 Add 18% GST 69 Add 1.00% Labour Welfare Cess