Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Construction Work of Classn Room Block, Guard Room, Toilet Block & Cycle Stand Shed at Govt. Girls Degree Gollege, Roberts Ganj District-Sonbhadra. |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 3 | All kinds of soil. |
| 4 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 5 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport up to a lead of 5 km, also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc., complete. |
| 6 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 7 | 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources). |
| 8 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 9 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources). LINTEL |
| 10 | Ground Floor |
| 11 | First Floor |
| 12 | Mumty |
| 13 | Ground Floor |
| 14 | First Floor |
| 15 | Mumty |
| 16 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : |
| 17 | 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 18 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources). |
| 19 | Ground Floor |
| 20 | First Floor |
| 21 | Mumty |
| 22 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : |
| 23 | 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 24 | Boring with hydraulic piling rigs with power units, Providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto the bottom of pile cap): |
| 25 | 300 mm dia piles |
| 26 | Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. |
| 27 | Single pile upto 50 tonne safe capacity |
| 28 | Initial test. ( Test load 2.5 times the safe capacity) |
| 29 | Routine test ( Test load 1.5 times the safe capacity) |
| 30 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : |
| 31 | 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) COLUMN |
| 32 | Ground Floor |
| 33 | First Floor |
| 34 | Mumty |
| 35 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: |
| 36 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 37 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: |
| 38 | Cement mortar 1:4 (1 cement : coarse sand) |
| 39 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources). |
| 40 | Providing and applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. |
| 41 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
| 42 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 43 | Ground Floor |
| 44 | First Floor |
| 45 | Mumty |
| 46 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. |
| 47 | Cement mortar 1:4 (1 cement :4 coarse sand) |
| 48 | Ground Floor |
| 49 | First Floor |
| 50 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 51 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 52 | Ground Floor |
| 53 | First Floor |
| 54 | Mumty |
| 55 | 15 mm cement plaster on rough side of single or half brick wall of mix : |
| 56 | 1:4 (1 cement: 4 coarse sand) |
| 57 | 15 mm cement plaster on rough side of single or half brick wall of mix : |
| 58 | 1:6 (1 cement: 6 coarse sand) |
| 59 | Ground Floor |
| 60 | First Floor |
| 61 | Mumty |
| 62 | 12 mm cement plaster of mix : |
| 63 | 1:6 (1 cement: 6 coarse sand) |
| 64 | Ground Floor |
| 65 | First Floor |
| 66 | Mumty |
| 67 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections |
| 68 | Ground Floor |
| 69 | First Floor |
| 70 | Mumty |
| 71 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc.,., complete. |
| 72 | Ground Floor |
| 73 | First Floor |
| 74 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kgper sqm including pointing the joints with white cement mixed with pigment of matching shade complete. |
| 75 | Ground Floor |
| 76 | First Floor |
| 77 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
| 78 | Double charge vitrified tile polished finish of size |
| 79 | Size of Tile 600 x 600 mm |
| 80 | Ground Floor |
| 81 | First Floor |
| 82 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08%and conforming to IS: 15622, of approved brand & manufacturer in all colours and shade in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints(Payment for grouting of joints to be made separately). |
| 83 | Size of Tile 600x600 mm |
| 84 | Ground Floor |
| 85 | First Floor |
| 86 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. |
| 87 | Granite stone slab colour black, Cherry/Ruby red |
| 88 | Area of slab over 0.50 sqm |
| 89 | Ground Floor |
| 90 | First Floor |
| 91 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation leveling & dressing & finishing the top smooth. |
| 92 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: |
| 93 | 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 94 | Ground Floor |
| 95 | First Floor |
| 96 | Mumty |
| 97 | Providing and fixing mild steel round holding down bolts with nuts and washer plates complete. |
| 98 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. |
| 99 | In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 100 | Ground Floor |
| 101 | First Floor |
| 102 | Mumty |
| 103 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, priming coat of approved steel primer, but excluding the cost of other fittings, glass panes complete all as per approved design, (sectional weight of only steel members shall be measured for payment). |
| 104 | Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) |
| 105 | Ground Floor |
| 106 | First Floor |
| 107 | Mumty |
| 108 | Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. |
| 109 | Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) |
| 110 | Ground Floor |
| 111 | First Floor |
| 112 | Mumty |
| 113 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. |
| 114 | Ground Floor |
| 115 | First Floor |
| 116 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer, of required shade and colour all complete : |
| 117 | New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 118 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade |
| 119 | New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 120 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 121 | Ground Floor |
| 122 | First Floor |
| 123 | Mumty |
| 124 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. |
| 125 | Twin rubber stopper |
| 126 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : |
| 127 | 250x16 mm |
| 128 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 129 | 250x10 mm |
| 130 | 200x10 mm |
| 131 | Providing and fixing aluminium handles ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 132 | 125 mm |
| 133 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: |
| 134 | (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. |
| 135 | (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. |
| 136 | (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge. |
| 137 | (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. |
| 138 | (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : |
| 139 | With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 140 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : |
| 141 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand or manufacture |
| 142 | Ground Floor |
| 143 | First Floor |
| 144 | Mumty |
| 145 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : |
| 146 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture |
| 147 | Ground Floor |
| 148 | First Floor |
| 149 | Mumty |
| 150 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows all complete with : |
| 151 | 4.0 mm thick glass panes. |
| 152 | Ground Floor |
| 153 | First Floor |
| 154 | Mumty |
| 155 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 156 | Foundations, footings, bases of columns, etc. for mass concrete |
| 157 | Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick |
| 158 | Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick |
| 159 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 160 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 161 | 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded Stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2(1 cement hardener mix: 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture\"s specifications. This includes cost of cement slurry, but excluding the cost of nosing of Steps etc. complete. |
| 162 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m Iong complete as per standard design |
| 163 | Providing and laying water proofing treatment on roofs oi slabs by applying cement slurry mixed with water proofing cement compound consisting of applying; |
| 164 | (a) after surface preparation, first layer of slurry o Cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. |
| 165 | (b) laying second layer of Fiber glass cloth when the first layer is still green. Overlaps Of joints of fiber cloth should not be less than 10 cm. |
| 166 | (c) third layer of 1.5 mm thickness consisting of slurry o cement @ 1.289 kg/sqm mixed with water proofing Cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. |
| 167 | (d) fourth and final layer Of brick tiling with cement mortar which Will be paid for Separately) |
| 168 | For the purpose of measurement the entire treated surface will be measured. |
| 169 | Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. |
| 170 | Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. |
| 171 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 172 | Electric resistance or induction butt welded tubes. |
| 173 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 174 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer\"s specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work |
| 175 | PLUMBERING WORK. |
| 176 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings andfixtures complete, including cutting and making good the walls and floors wherever required : |
| 177 | W.C. pan with ISI marked white solid plastic seat and lid |
| 178 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: |
| 179 | White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap |
| 180 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : |
| 181 | One urinal basin with 5 litre white P.V.C. automatic flushing cistern |
| 182 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 183 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 184 | Semi rigid pipe |
| 185 | 32 mm dia |
| 186 | 40 mm dia |
| 187 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. |
| 188 | Providing and fixing toilet paper holder : |
| 189 | C.P. brass |
| 190 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 191 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 192 | (i)Single socketed pipes. |
| 193 | 110 mm diameter |
| 194 | Making khurras 45x45 cm with average minimum thickness of5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 195 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 196 | 110 mm |
| 197 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. |
| 198 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. : Internal work – Exposed on wall. |
| 199 | (internal work) |
| 200 | Exposed on wall |
| 201 | 32 mm dia. nominal bore |
| 202 | Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality : |
| 203 | 32 mm diameter pipe |
| 204 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall |
| 205 | 25 mm nominal outer dia .Pipes. |
| 206 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. :Concealed work, including cutting chases and making good the walls etc. |
| 207 | 15 mm nominal outer dia .Pipes. |
| 208 | 20 mm nominal outer dia .Pipes. |
| 209 | 25 mm nominal outer dia .Pipes. |
| 210 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
| 211 | 45 cm length |
| 212 | 15 mm nominal bore |
| 213 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931: |
| 214 | 15 mm nominal bore. |
| 215 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: |
| 216 | Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. |
| 217 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : |
| 218 | 25 mm nominal bore |
| 219 | 32 mm nominal bore. |
| 220 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : |
| 221 | 25 mm nominal bore |
| 222 | Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includesmaking necessary holes for inlet, outlet & over flow pipes. The base support i/c fittings & fixtures for tank shall be paid separately. |
| 223 | Supply and fixing of UPVC S.W.R. pipe nahni trap size 100x75, 110/90 mm confirming to IS-14735 self cleaning design fixed in PCC 1:2:4 and supply and fixing of 125 mm dia heavy duty CP brass jali. |
| 224 | Supply and fixing of UPVC S.W.R. Cowel confirming to IS-14735. |
| 225 | Size 75/90 mm |
| 226 | Size 110mm |
| 227 | Supply and fixing of brass Health Faucet with Braided 1 meter Flexible Hose |
| 228 | Size 75/90 |
| 229 | Supply and fixing of UPVC S.W.R. pipe type-B confirming to IS-13592 including jointing the pipes with rubber ring lubricant and UPVC SWR cupler confirming to IS-14735. Also including excavation of treanches cutting of walls and holes and repairing the walls, floors and refilling the trenches as before with supply and cost of other fittlings such as elbow,bend,tee and y-tee, Cowel Including supply of all marerial labour and T&P. Required for proper completion of work. |
| 230 | 75 mm O.D. |
| 231 | 110 mm O.D. |
| 232 | Supply and fixing of UPVC S.W.R. pipe nahni trap size 100x75,110/90 mm confirming to IS-14735 self cleaning design fixed in PCC 1:2:4 and supply and fixing of 125 mm dia heavy duty CP brass jali. |
| 233 | ELECTRICAL. |
| 234 | Wiring for light point with 1.5 sq.mm FRLS PVC Insulated copper conductor single core cable in surface / recessed medium class PVC condult, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group C |
| 235 | Wiring for fan point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium clase PVC conduit, with modular switch, modular plate, sultable Gl box and earthing the point with 1.5 sq.mm. FRLS PVC Insulated copper conductor single core cable etc as required Group C |
| 236 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 237 | 2X1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 238 | 2 X2.5 sq. mm + 1X2.5 sq. mm earth wire |
| 239 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 240 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 241 | 2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 242 | 4 X 10 sq. mm + 2X6 sq. mm earth wire |
| 243 | 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 244 | Supplying and drawing following pair 0.5 sqmm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 245 | 2 Pair |
| 246 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 247 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 248 | 25mm |
| 249 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 250 | Telephone socket outlet |
| 251 | TV antenna socket outlet |
| 252 | Bell push |
| 253 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 254 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 255 | Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 256 | Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 257 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 258 | Supplying and fixing call bell/ buzzer suitable for single phase, V, complete as required. |
| 259 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 260 | Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required. |
| 261 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
| 262 | Up to 450 mm sweep |
| 263 | Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. |
| 264 | Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). |
| 265 | Providing and fixing circular/Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73mm height, top lid of 1.5 mm thick MS DSR-sheet with its top surface hacked for proper bondine top lid shall be screwed into the cast iron/MS sheet box by means of 3.3 mm dia round headed screwed. one loc at the conrners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing |
| 266 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 267 | DISTRIBUTION BOARD, MCB\"S & ISOLATORS : |
| 268 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
| 269 | 100A, 30KA FPMCCB |
| 270 | 125A 36 KA, FPMCCB |
| 271 | Supplying and fixing following way, single pole and neutral sheet steel, MCB distribution board, 240 V on surface/recess complete with, tinned copper busbar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB/RCCB/Isolators). |
| 272 | 8 way Double Door |
| 273 | Supplying and fixing following way, Horizontal type three pole and neutral MCB distribution board, 415 volts on surface /recess complete with, tinned copper busbar, neutral busbar, earth bar, din bar. Interconnections, powder painted including earthing etc. as required (But without MCB/RCCB/Isolators). |
| 274 | 4 way (4+12)Double Door |
| 275 | 6 way (4+18)Double Door |
| 276 | Supplying and fixing following way, surface/recess mounting vertical type 415V, TPN MCB distribution board, on steel sheet, dust protected, duly power painted, inclusive of 200 A tinned copper busbar. common neutral link, earth bar, din bar, for mounting MCBs (But without MCBs and incomer) as required(Note:vertical type MCB TPDB is normally used where 3 phase outles are required.) |
| 277 | 4 way (4+12)Double Door |
| 278 | Supplying and fixing 5 amps. to 32 amps. rating, 240 volts \"C\" series, miniature circuit breaker (MCE suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 279 | single Pole |
| 280 | Supplying and fixing single pole, blanking plate in the existing MCB DB complete etc. as required. |
| 281 | Supply and fixing 20 amp, 240 volts, SPN industrial Type, socket outlet With 2 pole and earth metal enclosed plug top along with 20 amp. C series SPMCB in sheet steel encosure, on surface or in recess with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 282 | Providing and fixing M.V. danger notice plate of 200 mmx150 mm, made of mild steel, at least 2 mm thick, and viterous enameled white on both sides, and with incription in single red colour on front side as required. |
| 283 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution borad, 415 Volts, on surface/recess, complete with testing commissoning ect. as required. |
| 284 | For 4 way, Double Door TPNMCBDB |
| 285 | For 6 way, Double Door TPNMCBDB |
| 286 | Supply and installing of following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, jointed with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. |
| 287 | 450mm width x 62.5mm depth x 2.0mm thickness |
| 288 | Earthing with GI earth pipe, 600 mm X 600 mm X 6 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/cock and salt as required. |
| 289 | Supplying and Laying of 25 mm X 3 mm G.I strip at 0.50 metre below ground as strip earth electrode. including connection / terminating with nut, bolt, spring, washer etc. as required.( jointing shall be done by overlapping and with 2 sets of G.L. nut bolt & spring washer spaced at 50mm) |
| 290 | Providing & fixing 6 SWG dia G.1. on surface or in recess for loop earthing as required. |
| 291 | Supplying & making end termination with brass compression gland and aluminium lugs for the following size of PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 292 | 2 X 6 sqmm. (19mm) |
| 293 | 3.5 X 25 sqmm. (28mm) |
| 294 | 3.5 X 35 sqmm. (32mm) |
| 295 | 3.5 X 185 sqmm. (57mm) |
| 296 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.L. fittings including trenching (75 cm deep) and refilling etc as required. |
| 297 | 100 mm Dia |
| 298 | Supplying & laying of following size DWC HDPE pipe ISI marked alongwith all accessories like socket, bend, couplers etc. confirming to IS: 14930 Part-Il complete with fitting, cutting & jointing etc, direct in ground (75cm below ground level) including excavation & refilling the trench but excluding sand cushioning & protective covering etc. as required. |
| 299 | 90 mm dia (OD-90 mm & ID-76 mm nominal) |
| 300 | Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required. |
| 301 | 40 mm Dia |
| 302 | Supplying and drawing following size of FRLS PVC insulated copper conductor, single core cable in existing surface/ recessed medium class PVC conduit as required. |
| 303 | 3X2.5 sqmm |
| 304 | Supplying and laying of aluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top as directed by Engineer-Incharge complete in all respect including excavation and refilling. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. |
| 305 | 6Sqmm 2Core |
| 306 | 25 sqmm 3.5 Core |
| 307 | Supply & fixing of 7 mtr G.I. Octagonal Pole of approved make (top dia 70mm, Bottom dia 130 mm and base plate 12mm thik) having 3mm thikness with Single Arm bracket (1 Mtr length) on 1:2:4 RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect. |
| 308 | Supply and fixing of LED Tube Light with heavy Duty Metal Box type Tube Light Fitting 1x22 watt suitable for upto 1x22 watt LED Polycarbonate tube light complete Including tube suitable for both surface & suspended complete in all respect. |
| 309 | 2620 system lumens,with fully covered diffuser type>120 lm/w PF>.95,THD<10%, CRI>80, sheet thickness min 0.8mm, Tube with aluminium heat sink, >300V over voltage protection, 2.5 KV internal Surge protection, with 5 years Warrantee.CAT.-AAA |
| 310 | Supply and fixing of LED Street light Fitting with mandatory driver set having die cast aluminium body with toughend glass/UV stabilised PC cover and lences suitable for 75 watt to 90 watt and Confirming to IP 66, and IK07 and above protection having Company LOGO Engraved complete in all respects including Labour |
| 311 | 9000-10800 system lumens, High Power LED with Lenses, 120 lm/W, PF>.95, THD<10%, at full load, CRI>70, Potted driver set in Metal housing(not circuitory) Phase to phase protection at 440V & >300V auto cut and re-start feature, 4 KV internal Surge protection with 5 years Warrantee.CAT.-AAA |
| 312 | Supply, Installation, Testing and Commissioning of L.T. Panel vermin proof floor mounting, M.S. Channel Base with bottom and Fabricated out of 2.0/1.6 mm thik CRCA sheet steel painted with powder coated paint of shade as per the direction of Engineer In charge after proper sheet treatment process of sheet steel. The bus bar of panel shall be electrical grade high conductive alluminium alloy of appropriate cross section as per the rating. The main busbar shall be run throughout the panel of rating as main incomer rating. The Bus Bar shall be supported by non hygroscopic SMC/DMC Bus bar suports which shall be mounted on proper interval to ensure the bear the jerks of suport of short cuircuit of 50kA for panels having ACB as Incomer & 36 kA for panels having MCCB Incomers. Panel shall be constructed in fully Segregated Compartment Design for each Feeder as per 3b construction Format. The panel shall be completed in all respect as per IS 8623 Part 2 & 3. There shall be Seperated metering Component for Incomer metts. on the Cclamps with EPD |
| 313 | All Incomer Feeders shall be provided with Multifunctional metering along with phase Indicating lights and other associated components such as CT control MCB Terminal Blocks etc. and all outgoing Feeders 100 A & above shall be provided with 3 phase Ammeter along with phase Indicating lights and other associates components such as CT control MCB Terminal Blocks etc. The feeder above shall be provided ac accommodated all measuring instrument shall be digital type & all indicating lights ahall be LED type. Wiring shall be done from 1100V Grade PVC Insulated copper flexible wire. All ACB shall be electricaly operated Draw out Type with microprosser based O/L, S/C & E/F Release off Breking/withstand capacity(ICU/ICs/lcw) 50 kA or more. All MCCB shall be thermal magnetics/microprossor with O/L & S/C protection along with required Spreders Extended rotary handle with pad locking facility of bracking capacity(ICU/ICS) 36 kA or more All MCB shall be Thermal 10kA \"C\"Curve Cubical type switch board shall be Cat-A and B only. |
| 314 | L.T. PANEL |
| 315 | 250 Amp. 4P MCCB-1No |
| 316 | Cat. B Panel Cubicale Type |
| 317 | Metering |
| 318 | One (1) No. (0-500V) 96 x 96 Sqmm voltmeter with control fuse & selector switch. |
| 319 | One (1) No. (0-250) 96 x 96 Sqmm CT operated Ammeter with selector switch, CTs etc. |
| 320 | One (1) Set of Phase Indication Lamp. |
| 321 | Bus Bar: |
| 322 | One (1) No.320 A. TPN aluminimum bus bar of suitable length. |
| 323 | Outgoing |
| 324 | Phase indication lamps on each outgoing to be provided |
| 325 | 125 Amp. 4P MCCB-2 No. |
| 326 | 100 Amp. 4P MCCB-1 No. |
| 327 | 63 Amp. 4P MCB-1 No. |
| 328 | 40 Amp. 4P MCB-2 No. |
| 329 | 32 Amp. SP MCB-1 No. |
| 330 | 100 Amp. 4P MCCB-1 No.-Spare |
| 331 | 63 Amp. 4P MCB-1 No.-Spare |
| 332 | 40 Amp. 4P MCB-1 No.-Spare |
| 333 | OR outgoing as per site requirment(AS/SLD) |
| 334 | LT. FEEDER PILLER-LOC ON SITE |
| 335 | Supplying assembling erecting connecting, testing and commissioning of feeder pillar with over voltage and under voltage relay with auto re-setting, manufactured using 1.9/1.6 mm thick CRCA sheet steel with power coated paint double door (front operated)with canopy base channel and cable gland entry from bottom for cable using, suitable alluminium busbar with provision of incoming & outgoing MCCB/MCB of L&T/Schneider/GE/ABB or Eq. make. Installation of feeder pillar of suitable c.c foundation etc complete in all respect. |
| 336 | Incoming: |
| 337 | 1No. Of 250 Amps 4P MCCB of 36 KA service breaking capacity and 250 Amp trip setting. |
| 338 | Metering: Voltmeter, Ammeter, Indication |
| 339 | Bus Bar: |
| 340 | 1 Set of 320 Amps TPN Aluminium Bus Bars of suitable length and of cross section. Bus bar shall be insulated by heat shrinkable sleaves & clip on shrouds for joints. Bus bar shall be designed to with stand a fault level of 36 KA at 415 volts. |
| 341 | 3Nos. Phase indicating lamp each lamp shall have one toggle switch. |
| 342 | Outgoing: |
| 343 | Phase indication lamps on each outgoing to be provided. |
| 344 | 250Amp 4P MCCB (36kA)-1 Nos. |
| 345 | Supply & Fixing of 1X17 W mirror light complete in all respects. Make-Philips or Eq |
| 346 | Supply of AC 230/250 Volts, 50 Hz 55w 1400 rpm exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required.Make: Havells-STANDARD Refresh Air-SPS |
| 347 | 300mm sweep |
| 348 | Supply and fixing following rateing four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 349 | 40 A,4P MCB-Bracking Capacity-10 kA, C-Curve-Make-Havells |
| 350 | 63 A,4P MCB-Bracking Capacity-10 kA, C-Curve-Make-Havells |
| 351 | S/f of 10/20 pair Junction Boxes for Floors and building with Krone connectors, with connection and punching of same |
| 352 | Supply of 12 W LED BULB complete in all respect. Make-Philips or Eq |
| 353 | Supply of LED Tube Light with batten suitable for up to 1X20 watt LED tube light complete including tube etc. on surface/Pendent complete in all respect.Make-Philips or Eq |
| 354 | EXT. WATER SUPPLY. |
| 355 | Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m. including getting out the excavated soil & then returning the soil as required, |
| 356 | in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m. |
| 357 | Pipes, cables etc. not exceeding 80mm dia. |
| 358 | Providing & fixing G.l. pipes complete with G.I. fittings including trenching and refilling etc. |
| 359 | External work |
| 360 | 32mm nominal bore. |
| 361 | 50mm nominal bore. |
| 362 | Providing & fixing sand of grading zone V or coaser grade alround the G.I. Pipes in external work. |
| 363 | 32 mm diameter pipe |
| 364 | 50 mm diameter pipe |
| 365 | Providing and fixing gate valve (with cap complete with bolts, nuts, rubber insertion etc. |
| 366 | 32 mm nominal bore |
| 367 | 50 mm nominal bore |
| 368 | Constructing masonry Chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement :4 coarse sand ) for sluice valve, with Cl. surface box 100mm top diameter, 160mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as er standard design : |
| 369 | With F.P.S. bricks |
| 370 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : |
| 371 | 25 to 40 mm dia nominal bore |
| 372 | 50 to 80 mm dia nominal bore |
| 373 | RAIN WATER HARVESTING. |
| 374 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over Areas (exceeding 30cm in depth. 1.5min width as well as on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatlydressed. |
| 375 | In all kind of soil upto 1.5m depth |
| 376 | In all kind of soil upto 1.5m to 3.0m depth |
| 377 | In all kind of soil upto 3.0m to 4.5m. depth |
| 378 | In all kind of soil upto 4.5m to 6.0m. depth |
| 379 | Providing and laying in position cement concrete of specified grade excluding the ccost of centering and shuttering -All work up to plinth level: |
| 380 | 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) |
| 381 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: |
| 382 | Cement mortar 1:4 (1 cement : 4 coarse sand |
| 383 | Reinforced cement concrete work In beams, suspended floors, roofs having slope up to 15 landings, balconies, shelves, chajjas, lintels, bands plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5 coarse sand :3 graded stone aggregate 20mm nominal size) |
| 384 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 385 | Mild steel and Medium Tensile steel bars. |
| 386 | Centring and shuttering including struting , proping etc and removal o form for : |
| 387 | Suspended floors, roofs, landings, balconies and access platform. |
| 388 | 15mm cement plaster on rough side of single or half brick wall mix |
| 389 | 1:4 1 cement : 4 coarse sand) |
| 390 | Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design: |
| 391 | With 20x20mm square bar |
| 392 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality |
| 393 | M.D. -10- Circular shape 500mm internal diameter |
| 394 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-incharge, upto 90 metre depth below ground level. |
| 395 | Drilling of 300mm dia bore hole manually |
| 396 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in charge. |
| 397 | 150 mm nominal size dia |
| 398 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer- in-charge. |
| 399 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer- in-charge |
| 400 | Supplying filling, spreading & leveling coarse sand of size range 1.5 mm to 2mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 401 | Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/medium/coarse, in required grading & size as per actual requirement, all complete as per direction of Engineer-in-charge. |
| 402 | Earth work in excavation by (Hydraulic mechanical means excavator)/manual means over areas(exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. |
| 403 | In all kind of soil upto 1.5m depth |
| 404 | In all kind of soil upto 1.5m to 3.0m. depth |
| 405 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -All work upto plinth level: |
| 406 | 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) . |
| 407 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: |
| 408 | Cement mortar (1 cement : 4 coarse sand ) |
| 409 | Reinforced cement concrete work In beams, suspended floors, roofs having slope up to 152 landings, balconies, shelves, chajjas, lintels, bands plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, finishing and shuttering, reinforcement with 1:1.5:3 (1 cement :1.5 coarse sand :3 graded stone aggregate 20mm nominal size) |
| 410 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 411 | Mild steel and Medium Tensile steel bars. |
| 412 | 15mm cement plaster on rough side of single or half brick wall mix |
| 413 | 1:4 1 cement : 4 coarse sand |
| 414 | Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design: |
| 415 | With 20x20mm square bar |
| 416 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality |
| 417 | M.D. -10- Circular shape 500mm internal diameter |
| 418 | Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m. including getting out the excavated soil & then returning the soil as required, |
| 419 | in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m. |
| 420 | Pipes, cables etc. exceeding 80mm dia. But not exceeding 300 mm dia. |
| 421 | Providing, laying and joining glazed stone ware pipes class SP-I with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. |
| 422 | 150mm diameter |
| 423 | 200mm diameter |
| 424 | Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design |
| 425 | 150mm diameter S.W. Pipe |
| 426 | 200mm diameter S.W. Pipe |
| 427 | Constructing brick masonry manhole with 75 class designation F.P.S. bricks in cement mortar 1:4 (1 cement : 4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand: 4graded stone aggregate 20mm nominal size); foundation concrete 1:4:8 mix |
| 428 | (1 cement :4 coarse sand: 8 graded stone aggregate 40mm nominal size) inside plasstering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 |
| 429 | (1 cement :2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design |
| 430 | a) Inside size 60x60 cm & 60 cm deep including C.I. cover with frame (light duty) total wt. of cover & frame to be not less than 38 Kg (wt. of cover 23 Kg & wt. of frame 15 kg. |
| 431 | FIRE FIGHTING. |
| 432 | (A) Supplying, Installation, Testing & Commissioning of Electric driven terrace pump suitable for automatic operation and consisting of following complete in all respects, as required (Terrace Pump) |
| 433 | (B) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal confirming to IS 1520 |
| 434 | (C) Suitable HP Squirrel cage indution motor, TEFC type suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-\"F\" insulation, confirming to IS-325. |
| 435 | (D) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. |
| 436 | (E) Suitable cement concrete foundation duly plastered with anti vibration pads. |
| 437 | 450 Ipm at 35 m head |
| 438 | Providing, laying, testing & Commissioning of \"C\" class heavy duty MS pipe confirming to IS 3589/IS1239 inculding welding, fittings like elbows,tees, langes,tapers,nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of syntetic enamel paint of required shade complete as required: |
| 439 | 25 mm dia |
| 440 | 100 mm dia |
| 441 | Supplying & fixing single headed internal yard hydrant valve with Instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel, ISI marked, confirming to IS 5290(type A) with blank Gunmetal/Stainless Steel cap and chain as required: |
| 442 | Single headed Gunmetal |
| 443 | Supplying, fixing, testing & commission of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets confirming to IS 13095 of following sizes as required: |
| 444 | 100 mm dia |
| 445 | Supplying & fixing orifice plate made out of 6 mm thick stainless steel(grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required |
| 446 | Providing, installation, testing and commission of non-return valve of following sizes confirming to 15. 5312 complete with rubber gaskets Gl bolts, nuts, washers etc as required: |
| 447 | 100 mm dia |
| 448 | Supplying & fixing 63 mm dia, 15m long RRL hose pipe with 63 mm dia male and female couplings duly bound with Gl wire, rivets etc. confirming to IS 636(type-A) as required: |
| 449 | Gun Metal |
| 450 | Supplying & fixing First-aid hose Reel with MS construction spray painted in post office red.conforming to IS 884 complete with the following as required. |
| 451 | 20 mm nominal internal dia water hose thermoplastic(Textile reinforced) type-2 as per IS:12585 |
| 452 | 20 mm nominal internal dia gun metal globe valve & nozzle. |
| 453 | Drum and brackets for fixing the equipments on wall. |
| 454 | Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. |
| 455 | 30 m |
| 456 | Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle confirming to 15:903 suitable for instantaneous connection to interconnect hos pipe coupling as required. |
| 457 | Gun Metal |
| 458 | Supplying & fixing air vessel made out of 250 mm dia,8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required. |
| 459 | Providing & fixing of pressure switch in M.S. 19.12 pipeline including connection etc as required |
| 460 | Supplying, installation, testing & commissioning uf Manual call Boxes of MS constuction in surface/recess with stainless steel chain & bammer assembly complete with glass and push button etc, as required |
| 461 | Supplying installation, testing & commissioning fire alarm sounder with facility to make announcement mounted in M.S. box(16 SWG) with hinged cover plate & suitable for operation with amplifier l/c line matching trasformer etc. complete as required. |
| 462 | Supplying installation, testing & commissioning talk back slave station in surface/recess suitable for operation on simplex mode complete with P.T.T. knob & speaker/microphone cenclosed in a M.S. box(16 SWG)/ABS box with break glass in front etc. complete as required |
| 463 | Supplying & laying of 2X1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. |
| 464 | Supplying & laying 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. |
| 465 | Supply and fixing of following sizes of medium class PVC conduit alongwith the accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required: |
| 466 | 25 mm |
| 467 | Supplying, Installation, testing & commissioning of main control and indicating panel made out SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections, interconnections etc complete as required. |
| 468 | 100 Watt amplifier racks suitable for operation on 230V AC/24VDC supply confirming to IEC-268 3 complete with all accessories as required-2 Nos. (one to act as standby) |
| 469 | Talk back master station with LED PTT(press to talk) push button for operation on 230V AC/24 V DC supply confirming to IEC-268 for simplex mode of operation/communication suitable for 20 Nos, talk back unit-1 set. |
| 470 | Annoucement control desk suitable for selection of different zones selectively and ON ALL CALL Switch with visual indication etc. complete as required-1 set |
| 471 | Amplifier change over switch for inter changingamplified-1 No. |
| 472 | Monitor panel for loudspeaker complete with output selector, ON/OFF switch fase, visual Indications etc. complete as required-1 No. |
| 473 | Gooseneck microphone with stand and ON/OFF switch-1 No. |
| 474 | Main ON/OFF switch,fuse indication lamps, DC and AC voltmeters & ammeters, terminal blockes etc. complete as required-1 set. |
| 475 | Battery charger trickle cum boost to take complete load of fire alarm & PA system complete with all accessories including providing & fixing of 2 nos 12 volt. 60 AH each sealed maintenance free bateries-1 set. |
| 476 | Providing, laying, testing & Commissioning of \"C class heavy duty MS pipe confirming to 15 3589/IS1239 inculding welding, fittings like elbows,tees, langes,tapers,nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of syntetic enamel paint of required shade complete as required: |
| 477 | 80 mm dia |
| 478 | 100 mm dia |
| 479 | Supplying & fixing single headed external yard hydrant valve with 1 No. 63 mm dia Instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, confirming to IS 5290(type A) with blank Gunmetal/Stainless Steel cap and chain as required: |
| 480 | Single headed Gunmetal |
| 481 | Supplying, fixing, testing & commission of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets confirming to IS 13095 of following sizes as required: |
| 482 | 80 mm dia |
| 483 | 100 mm dia |
| 484 | Providing, installation, testing and commission of non-return valve of following sizes confirming to 15: 5312 complete with rubber gaskets Gl bolts, nuts, washers etc as required: |
| 485 | 100 mm dia |
| 486 | Supplying & fixing 63 mm dia, 15m long RRL hose pipe with 63 mm dia male and female couplings duly bound with Gl wire, rivets etc. confirming to 15 636(type-A) as required 116 |
| 487 | Gun Metal |
| 488 | Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internall diameter size nozzle confirming to 15:903 suitable for instantaneous connection to interconnect hos pipe coupling as required Gun Metal |
| 489 | Gun Metal |
| 490 | Supplying & fixing of Fire brigade connection of cast iron body with gun metal male instantaneous inlet coupling complete with cap and chain as required. for suitable dia MS pipe connection conforming to IS 904 as required: |
| 491 | 2 way-100 mm dia M.S. Pipe |
| 492 | Supply & fixing of fire extinguisher, ABC Type 6.00 kg. capacity(ISI Marked IS:15683 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 493 | Supply & fixing of CO2 type fire extinguisher. 6.5 kg. capacity (ISI Marked IS:2878 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 494 | Providing/Fixing of Fire Hose cabinet box made out of 18 gauge MS sheet including two coats of post office red paint over one coat of primer with 4 mm, thick glass door in front painted \"FIRE\" in red luminous paint. The size of the box should be 750 mm X 600 mm X 250 mm size capable of accommodating a pair of hose with coupling and nozzle. The box should be floor mounted type with railway coach lock arrangement and lever for opening the door after breaking the glass complete. Make: Standard/Lifeguard or EQ. |
| 495 | Providing & Fixing of 1.6 mm thick M.S / Door Frame, Door capable of accommodating fire Hose Reel, Landing Valve, Hose Pipes, fittings & accessories. The door shall have a front glass with lock and key arrangement & shall be painted with post office red colour (approval shall be taken on the basis of submitted sample before ordering).(Liasioing with civil contractor for making Recessed type mansoary box (by civil contractor). |
| 496 | Supplying and fixing of Self Glow Exit signage for stairs and exits made out from not less than 4 mm of transparent acrylic sheet of 300 x 150 mm size with self illuminated plastic words of 100 mm height suspended from ceiling by means of M.S. chain or fixed of the walls as required and as directed at site.(MAKE: Agni Suraksha (ASES) /Securiton-aka/System Sensor) |
| 497 | Supplying and fixing of Fire man axe. Make: Agni Suraksha (ASES) or EQ |
| 498 | Supply, Installation, Testing and Commissioning of electronic siren with suitable audible range of 1 k.m. approximately 4 watt.complete in all respects. Make:- Agni Suraksha (ASES) or EQ. |
| 499 | Providing/Fixing of cubical type floor mounted Fire pump control panel fabricated from 16 G M.S. sheet duly powder coated finish of approved shade and comprising of:Incomer:-a) 63 amp 4 Pole MCCB, 50Hz with breaking capacity 10KW.b)One Volt meter (0-500 V) with selector switch.c) Ammeter (0-63 Amps.) with selector switch & CT\"s. - 1 Setd) Set of 3 phase indication lamps - 1 Set e)Set of Al bus bar 200 Amp 4 strip- 1 Set Selector switch for local/remote, auto/manual/off operation ON/OFF indication lamp etc. - 1 Set |
| 500 | Outgoing:-1 x 63 Amps FP MCCB (25 KA) with Suitable HP fully automatic Star/Delta Starter with over load protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation. |
| 501 | TUBE WELL. |
| 502 | Boring/drilling hore well of required dia for casing/strainer pipe, by suitable method prescribed in 15 2800 (part 1), including collecting samples from different strata, preparing and submitting strata chart/hore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. 23.1.1 All types of soil |
| 503 | 300 MM dia |
| 504 | Boring/drilling bore well of required dia for casing/strainer pipe, by suitable method prescribed in 15: 2800 (part 1), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, beyond 90 metre & upto 150 metre depth below ground level. |
| 505 | 300 MM dia |
| 506 | Supply, assembing, lowering and fixing in vertical position in bore well ERW (Electric Resistance welded )FE 410 mild steel screwed and socket/plain ended casting pipe of required dia, conforming to IS: 4270, of reputed & approved make including painted with out side surface with two coats of anticorrosive including required hire and labour charges, fitting & accessories etc. all complete, for all depths as per direction of Engineer-in-charge. |
| 507 | 100 mm nominal size dia having minimum wall thickness5.00 mm |
| 508 | 150 mm nominal size dia |
| 509 | Supplying, filling, spreading & leveling coarse sand of size range 1.5mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts,all complete, for all depths as per direction of Engineer-in charge. |
| 510 | Development of tube well in accordance with IS: 11189, to establish maximum rate of usable water yield without sand content, with required capicity air compressor, running the compressor for required time till well is fully developed, measuring static level & draw down etc. by step draw down method collecting water sample & getting tested in approved laboratory, i/c/ disinfection of tubewell, all complete, including hire & labour charges of air compressor. tools & accessories etc. all as per requirement and direction of Engineer-in-charge. |
| 511 | Providing and fixing suitable size threaded mild stee cap or spot weldedplate in the top of bore well housing casing pipe removable as per requirement all complete for borewell of |
| 512 | 100 min nominal size dia |
| 513 | 150 mm nominal size dia |
| 514 | Providing and fixing M.S. clamp of required dia to top of housing/casing pipe, of tubewell as per 15:2800 (PART-1) including necessary bolts & nuts (required size complete |
| 515 | 100 min nominal size dia |
| 516 | 150 mm nominal size dia |
| 517 | Providing and fixing Bail plug /Bottam plug of required dia to the hottam of pipe assembly of tubewell as per IS:2800 (PART-1) |
| 518 | 100 min nominal size dia |
| 519 | 150 mm nominal size dia |
| 520 | Supply of tubewell motar pump of 500 lit/min discharge w/h. of control panel, support wire etc. complete 5 H.P. one emergency pump. |
| 521 | as per market rate |
| 522 | Water supply tanker of 5000 litre capicity for boring |
| 523 | Supply and fixing of nylon jali around the slotted pipes complete as required. |
| 524 | Providing and fixing Cl. sluice valve. |
| 525 | 100 mm nominal bore. Class 1 |
| 526 | Providing and fixing G.l. pipes complete with G.L. fittings including etc.Submerssible to OHT trenchingand refilling etc.Submerssible to OHT |
| 527 | 80 mm dia nominal bore |
| 528 | Providing and lowering G.L. pipes complete with G.L. fittings including trenchingand refilling etc. |
| 529 | 50 mm dia nominal bore |
| 530 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge complete In all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. |
| 531 | 35 s4 mm 3-1/2 core |
| 532 | GST Extra as applicable |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy