| 1 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 2 | M&L colouredvitrified double charged tiles 8-10mm thick (square/rectangular) area of each tile exceeding 0.18sqm but not exceeding 0.36sqm as in floor etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the tiles including 20mm thick screed bed or bedding layer in CM 1:6complete all as specified. |
| 3 | -Ditto- all as per item No 2 here in before but on vertical surfaces of skirtings or dado etc with 10mm thick cement plaster complete all as sepcified and directed |
| 4 | M&L for 3.0mm thick PVC tiles/ sheets,laminated plain coloured, marbled mosaic or mottled finish, laid with approved rubber based adhesive in floors complete all as specofoed and directed |
| 5 | M&L Granite (of any type), 18-20mm thick (table rubbed and polished) in steps, jambs, pillars, window cills,cooking platform,WHB plateform and like in cement mortar (1:4) incl pointing in white cement (1:2) using marble dust with admixer of pigment to match with marble shade including 10mm thick backing of cement plaster in CM 1:3 complete all as specified. |
| 6 | M&L rounding to edges of stone slabs one edge,such as in steps, cooking platform and other similar situations complete all as directed |
| 7 | Dismantling of wall and ceiling boards (fibre,pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as directed |
| 8 | M&L for Anodised aluminium snap grid frame work for false ceiling of Size of grid 605 x 605mm complete all as specified and directed |
| 9 | S&F for Hangers 6 mm dia. G.I. (upto1200mm length) adjusting level fixed to roof slabs by means ofceilling cleats made out of G.I.flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified |
| 10 | M&L for 10mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/ Aluminium framework with screws on ceiling or slope roof complete all as directed |
| 11 | S&F for 80mm dia of mild steel tubes, med grade screwed down with socket, elbow etc complete all as specified and directed by Engr-in-Charge |
| 12 | M&L for cutting holes in brick/stone walls in mud or cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required incl necessary scaffolding etc complete all as specified and directed by Engr-in-Charge |
| 13 | M&L for complete removal of existing treatment and applying two coats of OBD over a coat of primer including 1mm thick plaster of paris on plastering of defected existing surfaces complete all as directed (Note:plastering shall be measured and paid in separately). |
| 14 | M&L for preparation of old steel surfaces of any description, not otherwise described, over 10cm width or girth and applying one coat of synthetic enemel paint complete all as specified and directed by Engr-in-Charge |
| 15 | M&L for preparation of old wooden surfaces of any description, not otherwise described, over 10cm width or girth and applying one coat of synthetic enemel paint complete all as specified and directed by Engr-in-Charge |
| 16 | Demolition of brickwork or stone/boulder masonry, built in cement or cement lime mortar including all quoins, arches, pillars,etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as directed |
| 17 | M&L for Pre-cast cement concrete block masonry with solid blocks type C-1, 1:3:6 (20mm graded agg) exc10cm in width and setting in mortar complete built in CM 1:6 in any description complete all as directed |
| 18 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water incl necessary scaffolding etc complete all as specified and directed |
| 19 | M&L for 15mm thick plastering in two layers of CM 1:4 on brick or concrete wall surfaces etcincluding necessary scaffolding etc upto 12 mtr height complete all as directed. |
| 20 | -Ditto- all as per item No 19, here in before but 15mm thick plaster in CM 1:6 on wall surfaces |
| 21 | M&L for preparation of new plastered surfaces of walls and applying two coats of cement base paint over a coat of primer complete all as specified and directed by Engr-in-Charge |
| 22 | M&L for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed by Engr-in-Charge |
| 23 | M&L for preparation of old surfaces of wall/ceiling/floor by filling cracks by crack fill paste of berger or of equivalent make as approved by GE, removing loose paints etc., removing nails etc and making good surfaces by applying white birla/JK wall care putty wherever required , smoothen surfaces by sand paper and applying two coats of acrylic exterior emulsion paint over a coat of primer of Bldg upto 12.0 m height complete all as specified and directed.Note: (i) The contractor shall furnish 5 years performance warranty as per manufacturer of paint(ii) The work should be done by a company recommended applicator and he should be able to furnish stage wise on site technical reports from the concerned complany technologist |
| 24 | Taking down chowkats or frames exc 1.50sqm but not exc. 4.0sq. m each with shutters of any description (without taking off shutters from the frames) complete all as specified and directed |
| 25 | Taking down of shutter area of each exc. 1.5 sq.m but n exc 4 sqmeachcomplete all as specified and directed |
| 26 | S&F double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover,governing pivot made of brass,other parts made of mild steel heavy duty and fixed complete all as directed |
| 27 | M&L for Powder coatinganodised aluminium frame for doors,windows, ventilators with one or morerebates (Min thickness of powder coating 50micron) including joining cleat for fixing etc. complete all as specified |
| 28 | S&F for powder coated anodised aluminium door shutters, aluminium section weighing 0.55 kg/m (Minimum thickness of powder coating 50micron) including 5.5mm thick figured glass, pin head type and glazing with oil putty in squares n.exc 0.5 sq. m in each panes with necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, locking system, hinges, anodised aluminum snap beading screws etc. complete all as specified. |
| 29 | S&F in repair for aluminium powder coated three track sliding window with two glazed shutters with 4mm thick float glass ordinary quantity and one shutter of stainless steel wire mesh 0.36 mm dia wire and 1.40mm aperture including good quality of bearing handle, locks, PVC rubber lining etc incl taking down existing old one complete all as specified and as directed. Catlouge numbers of Jindal company or equivalent make complete all as specified and directed. Sections of Jindal company : Three track bottom – 20957, Three track top/vertical – 20958,Handle – 20606, Interlocking – 20605, Top and bottom – 20604. |
| 30 | Dismantling single layer Mangalore pattern tiles or similar tiles in roofing including necessary fillets and similar items and taking out from the site without disturbing existing false ceiling complete all as directed. |
| 31 | M&L for roof tiles Mangalore pattern interlocking at side joints, laid dryclass A-A complete all as specified and as directed. |
| 32 | Fixing only roof tiles Mangalore pattern interlocking at side joints, laid dry complete all as specified and as directed. (Note : Serviceable tiles obtained from dismantled shall be re-used.) |
| 33 | M&L for ridge or hip tiles to suit Manglore pattern of roofing tiles,bedded and jointed in cement mortar (1:6) etc complete all as specified and as directed. |
| 34 | Fixing onlyfor ridge or hip tiles to suit Manglore pattern of roofing tiles,bedded and jointed in cement mortar (1:6) etc complete all as specified and as directed. |
| 35 | Dismantling plain or corrugated steel sheeting , any gauge, thickness including Nainital or similar pattern roof coverings complete all asdirected. |
| 36 | S&F for 0.63mm thick Plain Galvanised mild steel sheeting for mangalore roof, ridges, valley gutters drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 , both sides inclusive complete all as specified and directed. |
| 37 | S&F for 0.63mm thick Corrugated Galvanised mild steel sheeting with two corrugations side lap, fixed with coach screws and washers, in mangalore roofs, walls etc. with grade of zinc coating 275complete all as specified and directed. |
| 38 | Fixing only 0.63mm thick plain/corrugated galvanised mild steel sheeting as in ridge with grade of zinc coating120 gms/ sqm, both sides inclusive complete all as specified and as directed. (Note : Serviceable tiles obtained from dismantled shall be re-used.) |
| 39 | Dismantling battens of tiles of any size and description spaced exc. 15cm including tilting fillets complete all as directed. |
| 40 | S&F for 2nd class hardwood clean sawn tile battens, cross sectional areaexc 5 and n.exc 15 Sqcm spaced at 30 cm centresto centres fixed with nails incl one coat of creosate oil on new wooden surfaces complete all as specified and as directed. (NOTE : Measurements shall be taken overall including both battens and spaces. Deductions shall be made only for openings exceeding 0.4 sqm each). |
| 41 | All as per serial item No.40 here-in-before but except battens complete all as specified and as directed. (Note : Serviceable materials obtained from dismantled shall be re-used.) |
| 42 | Dismantling timber in scantling, fillets, rails, posts, rafters, purlins etc over 40 Sqcm in section in unframed work in any position complete all as directed. |
| 43 | M&L for 2nd class hard wood, clean sawn, in scantling timber unframed work complete all as specified and as directed. |
| 44 | Dismantling of eaves/ boarding any description and in any position fixed with nails complete all as directed. |
| 45 | M&L for Eaves/ weather boarding with 10mm thick fibre cement board (non asbestos) and fixed with self drilling and tapping screws of CSK head and joints finished with jointing compound and fiber tape as per manufacturer\"s recommendation complete of approved arch pattern any size and shape including two coat of synthetic enamal paint over one coat of suitable primer complete all as specified and as directed. Make: V-Board (Visaka Industries Ltd)/ Everest/ Charminar/ Ramco |
| 46 | Material and labour for point wiring using approved colour coding as per IS ,with multistranded copper conductor 1.5 Sqmm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade ISI-694 marked drawn through in and including heavy duty PVC concealed conduit including all accessories, Metal flush box of suitable module, with earth dolly, covered with twin colour (specified by Engr-in- Charge)modular white cover plate & frame after chasing in stone masonry walls etc for accomodating modular switches, sockets, regulators etc including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly, providing Copper cable sockets plate/ bottle type of adequate size at termination end of cable point wiring in DBs, switch boards, fittings fixtures all as specified and as directed for the following. |
| 47 | One light / wall / exhaust fan pointcontrolled by one, one way switch 6 Amps complete all as specified and as directed |
| 48 | One ceiling fan point controlled by one, one way switch 6 Amps and regulatorNote :PVCCasing caping /Pipe of size as required at site on surface of ceiling (only for fan point)in lieu of concealed is permitted and is deemed to be included in the unit rate quoated. |
| 49 | Onebell pointcontrolled by one, one way switch 6 Amps complete all as specified and as directed |
| 50 | One5 pin socket outlet plug point, 6 Amps, controlledby one, switchon same board complete all as specified and as directed |
| 51 | One5 pin socket outlet plug point, 6 Amps, controlledby one, switchon independent board complete all as specified and as directed |
| 52 | Description all as per 51 here-in before but using 2.5 Sqmm single core copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 Volts grade for one 6 pin socket outlet plug point,16 Amps independentincluding necessary running of 2.5 Sqmm PVC insulatedmultistranded copper conductor single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dollyproviding Copper cable sockets plate/ bottle type of adequate size at termination end of cable point wiring in DBs, switch boards, fittings fixturesall as specified and as directed |
| 53 | Supply and fixingModular Switch - 6 Amps, Single pole one way, one module complete all as specified andas directed. |
| 54 | Supply and fixingModular Bell push - 6 Amps, Single pole one way, one module complete all as specified andas directed. |
| 55 | Supply and fixingModular Switch - 16 Amps, Single pole one way, one module complete all as specified andas directed. |
| 56 | S & FModular socket outlet multipurpose 6 Amps, 5 pin, 2 module, complete all as specified andas directed. |
| 57 | S & FModular socket outlet multipurpose 16 Amps, 6 pin-shuttered type, 2 module, complete all as specified andas directed. |
| 58 | Supply and fixing, Ding Dongbell suitable for operation on AC. 230 volts, single pole complete all as specified andas directed. |
| 59 | Supply and fixing modular fan step regulator, 120W - 2 module suitable for ( 48\" & 56\" fans) supply complete all as specified and as directed. |
| 60 | S & F Ceiling rose, 3 phase / PVC / polycarbonate,complete all as specified andas directed |
| 61 | Supply and fixing20/22 Watt, 4 feetInverter LED Batten aluminium body with Opal Diffuser, IP20, Battery back-up & Functioning as per Product TDS with intregrated electronic driver, connector block, holder, decorative end caps, LED tube light etc complete with all accessories prewired and mounting PVC rectangular block, including provision of flexible copper conductor cable of suitable size from ceiling rose to connector and taking down old unserviceable fitting from existing postion for carrying to store, making good disturbed surfaces complete all as specified and as directed.Make Halonix Cat No LED INVERTER BATTEN HLB-08-22-CW-INV or equivalent in Havells, LHEXACP7FNIW020 |
| 62 | S & F for recess mounted 2\" x 2\" square LED panel 36 watts, 596 x 596 x 9mm size, sleek design aluminium housing, polycarbibate diffuser white powder coated finish operating voltage 140 volts - 270 volts, AC, 50 Hz complete all as specified and as directed. Make- Halonix HLFPR22-11-36-CW-37mm, Philips RC383B LED 4000 PSU ODWH PIR, Jaquar LULTU1S036XC. |
| 63 | Taking down carefully existing unserviceable main switch /cutout /DBs of any type, capacity and description and removing materials from site and making good disturbed surfaces of walls, floors as per the existing finishes all as specified and as directed. |
| 64 | S & F sheet metal enclosure MCB DB SPN 8 waywith 100 Amps rated bus bar 240 Volts double door with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick/ stone masonary etc and making good of disturbed surface to match the existing colour of wall complete all as specified and as directed |
| 65 | S & F Vertical TPNDistribution Board in sheet metal enclosure double door 4 Way, 415 volts, 50 Hz,suitable for Flush Mounting and surface Mounting & provision for FP MCCB as incomer up to 125 Amps as I/C( Frame1) and SP/TP MCB\"s as outgoing (Modules Optium F1+12) , With -100 Amps Copper insulated Busbar assembly for each phase, isolated Neutral bar, 2 Earthbar and Cable ties for cable management, IP 43 - #IK 09 with metal door including necessary cement work and electrical connections complete all as specified and as directed. |
| 66 | Supplied and fixed Four pole MCCB,Thermal Release Range 63-100 Amps, rupturing Breaking Capacity Icu at 415V AC 50Hz. 30 (kA)complete all as specified and as directed |
| 67 | Supply and fixing amp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB)SP 5 To 32 AMPand current carrying capacity in the MCB DB complete with connection testing and commissioning |
| 68 | Supply and fixing amp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB)SPN32 AMPand current carrying capacity in the MCB DB complete with connection testing and commissioning |
| 69 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. |
| 70 | Taking down of old unserviceable sub main wiring of any type complete all as specified and as directed. |
| 71 | S & F submain wiring with 2 single core (FRLS) PVC insulated unsheathed multistranded flexible copper conductor cable, of 6.0 Sqmm and one single core 6.0 Sqmm flame retardent low smoke (FRLS) PVC insulated, unsheathed, multistranded, flexible copper cable as earthing lead , all as per IS 694/1990 drawn through including concealed in stone masonary PVC conduit and conduit accessories heavy duty ISI marked,providing Copper cable sockets plate/ bottle type of adequate size at termination end of cable point wiring in DBs, switch boards, fittings fixturesall as specified and as directedall as specified and as directedcomplete all as specified andas directed.. Note :- ( Two runs of main copper wire, one run of earth wire cable & PVC conduit shall be measured together as one length). |
| 72 | S & F submain wiring with 2 single core (FRLS) PVC insulated unsheathed multistranded flexible copper conductor cable, of 4.0 Sqmm and one single core 4.0 Sqmm flame retardent low smoke (FRLS) PVC insulated, unsheathed, multistranded, flexible copper cable as earthing lead , all as per IS 694/1990 drawn through including concealedin stone masonary PVC conduit and conduit accessories heavy duty ISI marked,providing Copper cable sockets plate/ bottle type of adequate size at termination end of cable point wiring in DBs, switch boards, fittings fixturesall as specified and as directedall as specified and as directedcomplete all as specified andas directed.Note :- ( Two runs of main copper wire, one run of earth wire cable & PVC conduit shall be measured together as one length). |
| 73 | S & F S & F sub main wiring with approved colour coding as per IS with four single core PVC insulated FR-LSH cable with stranded copper conductor of size 10 Sqmm nominal area and drawing into PVC non metallic rigid heavy duty PVC conduit and its accessaries ISI markedheavy duty of suitable size includingconcealed in wall etc two runs of PVC insulated with 10 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire, all as per IS 694/1990 drawn through including concealedin stone masonaryPVC conduit and conduit accessories heavy duty ISI marked,providing Copper cable sockets plate/ bottle type of adequate size at termination end of cable point wiring in DBs, switch boards, fittings fixturesall as specified and as directedall as specified and as directedcomplete all as specified andas directed.Note :- ( Four runs of main copper wire, two run of earth wire cable & PVC conduit shall be measured together as one length). |
| 74 | S & F PVC rigid non-metallic flexible conduit ISI marked of dia 25 mm diainclusive of all tees, bends, elbows reducers, junction box etc and fixing accessories such as couplers, lock nuts, saddles, etc for telephone cable , TV cable and public address system including where required all as directed by Engineer-in- Charge duly concealed in wall complete all as specified and as directed |
| 75 | S & F PVC rigid non-metallic flexible conduit ISI marked of dia 20 mm diainclusive of all tees, bends, elbows reducers, junction box etc and fixing accessories such as couplers, lock nuts, saddles, etc for telephone cable , TV cable and public address system including where required all as directed by Engineer-in- Charge duly concealed in wall complete all as specified and as directed |
| 76 | S & F ofdown rod for ceiling fans made out of 15 mm diaMS pipe, medium grade duly threaded with clamp (factory fabricated) rubber reel, nuts, bolts etc complete all as specified and directed. |
| 77 | Supply, lay, joint, test and commissioning of LT under ground cable 1100 volt grade , XLPE insulated and PVC sheathed heavy duty armoured with aluminium conductor , IS 7098-I Marked, Laid in trenches/ducts/fixed on poles/walls/laid under roads/paths/drains/culverts or encased in GI pipe including cable glands, lugs jointing material etc complete all as specified and directed. cable of the following size.Note: Rate of under ground cable includes earth Work, sand cushioning, brick or PCC covering, light Grade GI tubing where necessary,testing etc. |
| 78 | (A) 16 Sq mm 4 Core |
| 79 | (B) 25 Sq mm 4 Core |
| 80 | S & F decorative LED bollard warm white with aluminum die casting, with adequate sizeelecrical connections complete all as specified and as directed. Make: Halonix Cat No HLOB-95-10-ww-01 (LLD0003139) |
| 81 | S&F for factory made street light control panel, with and including all accessories such as control switch, contactor, automatic control relay, pre-wired etc. fixed on fabricated angle iron channel of suitable size and grouting on floor, Timelite-32 Amps, 3 Pole 230/415 volts-Astronomical Time switch (suitable for Pune area),Make -Indo-Asian Cat No.TLO32ASO or equivalent in Havells, Legrand. |
| 82 | Material and labour for cutting existing road/hard standing for taking out pipe /making new connection and making good with PCC (1:2:4) type C 1 (using 20 mm graded broken stone aggregate) surface finished even and fair complete all as specified and as directed. |
| 83 | S & F decorative outdoor Garden light Caster antique fixture with E27 Holder & Lamp LED warm white of 35 Watts of dimensions D-230mmx H-1200mm, IP 54with powder coated aluminum die casting, with adequate sizeelecrical connections complete all as specified and as directed. Make: LukerLBF012E27 AG |
| 84 | S & F decorative outdoor Gate light Helios antique Fixture (Big) with E27 Holder & Lamp LED warm white of 60 Watts of dimensions D-230mmx H-500, IP-54with powder coated aluminum die casting, with adequate sizeelecrical connections complete all as specified and as directed. Make: LukerLGLA7e27AG AG |
| 85 | Supply and fixing LED flood light (halogen type) 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp with adequate sizeelecrical connections complete all as specified and as directed. |
| 86 | Supply and fixing LED strip lights with adequate sizeelecrical connections complete all as specified and as directed. |
| 87 | Excavation in trenches 1.5 Mtr wide and not exc 1.5 Mtr deep in hard/dense soil getting out and levelling of bottom surface to required level for laying UG cable complete all as specified and directed by Engr- in- charge. |
| 88 | Removing excavated material of soils from site to a distance not exc 50 mtr away and depositing where directed not exc 1.5mtr from the starting point. |
| 89 | Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick. |
| 90 | M & L for earthing complete with galvanised steel earth electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below the normal ground level) with top edge of the plate not less than 1.5 mtr below the normal ground level connected to the galvanised iron strip 32x6 mm (w/o protection pipe) as earthing lead by means of bolts,nuts, check nuts and washers of galvanised iron as shown inelectrical plate No 5 of SSR part I including necessary excavation and earth work GI pipe 20/30mm dia light grade for watering etc, PCC chamber with PCC cover in cement concrete 1:2:4 Type B1(20mm graded aggregate), funnel, wire mesh, charcoal dust, salt etc, connected to HT/LT poles/HIGH MAST /panel board/ as indicated including testing complete. |
| 91 | Note : 1. Performance security:- Refer Condition 22 of Special Conditions. 2. Quoted Contract Sum shall be arrived at after deducting the amount of Credit Schedule (refer Schedule of Credit in pdf form for quantity, rate and amount etc.) for old unserviceable materials retrieved from site. |