| 1 | COMPOUND LIGHTING:Supply & Delivery ofHotDip Galvanised (as per IS:2629 / IS 2633 / IS 4759 and with its latest amendment ) Octagonal Pole made ofHT steel( sheet thickness -3mm ) conforming tograde S355 of BSEN 10025 alongwith welded base plate of required sizeconforming to IS: 226 / 2062with integrated Control box with required sizes studs for termination of 2 core 10 /4 Core 16 sq mmAl (Armoured ) cable incld S&F1 No6 Amp SP MCB( C-Series )for each out going circuit to the fittings with proper pad locking arrangement for the followingpole-- 7 Mtr Long [ Top Dia ( A / F ) - 70 mm, Bottom Dia ( A / F ) -130 mm ]Base Plate Size : 200 mm x 200mm x 12 mm. (Make :Bajaj/Philips/Valmont/CG/Transrail/Bansal/Utkarsh ). |
| 2 | Errection of the following Octagonal pole by designing and Casting RCC ( M 20 ) foundation of suitable size as specified below considering the safe soil bearing capacity at site as T/sq m, including excavation of earth, providing, cutting, bending and placing in position reinforcement as per drawing and providing pipe for cable entry and exit as required and providing and fixing of 4 Nos foundation bolts ( J Type ) as specified below and as per drawing on ground surface including back filling and cleaning extra earth -7 Mtr Long [ Founation size - 500 mm X 500 mm X 1200 mm, J Bolt Size - 4 M 20 X 600 ] |
| 3 | SITCof single dip galvanized steeloverhang bracket ( Swan Neck Type/As per direction of the EIC ) at the top of the polehaving 1.5 Mlengthcomplete with all fixing arrangements as required including painting. Single Arm |
| 4 | SITCofroad lighting luminaire 250V,90W(Maximum) ( IP 65 ) with peanut lens andhigh power LED andto ensure uniform distribution, higher spacing between poles and maintenance free system and system lumen output will be minimum 7200 lumensuitable for use with 230Volt 50Hz AC supply etc as required. as directed by EIC.[Make: Philips BRP409 LED11 8 CW SLC FG PSU GR V2/ Havells/equivalent spec of Crompton] |
| 5 | Supply & Erection of mini pole of 2 Mtrs. long 80 mm. Dia. Seamless pipe (Jindal-ISI –M/Bhusan-ISI-M/utkarsh-ISI-M/Bansal-ISI-M) on roof of building by Supply & providing MS plate incl. Rose type arrangement nearby base plate for smooth cable entry position & making CC mortar mixture (6 : 3 : 1) and neat cement plaster & cheeping properly of drilling hole painting etc. As per direction of EIC (Muffing 0.3 x 0.3 dia.). |
| 6 | Providing CC (6:3:1) base block (around the pole) dimension 0.45x0.45x0.60 mt. above ground level,neatly cemented finished(3mm thick), at the base pole ( in lieu of CC muffing) incl. drilled hole in pole suitable for alkathine/polythene pipe entry, for street light wiring, without loop box. |
| 7 | S & F of Single arm header assembly fabricated from 40 mm dia G.I. pipe (ISI-M) of 2 Mtr. long rigidly welded with 100 mm dia G.I. pipe (ISI-M) of 0.3 Mtr. Long at an angle of 15 degree with horizonrtal axisincl. S&F 3 nos. 1/2\" MS jam nut each with 1 no. 1/2\" dia. through bolt and painting the entire assembly. |
| 8 | Supply & Fixingof of 40W LED Decorative post top light fittings with IP65 protection. ( Make: Crompton, Model no. LPTO-40-CDL-M or similar spec. of Philips/ Bajaj/Havells. |
| 9 | Fixing only above light fitting complete with all accessories, as directed by EIC. |
| 10 | Wiring by 3x 1.5 sqmm single core PVC insulated copper wirethrough polythene pipe from loop box to fitting as per GS.[Make-Finolex/KEI/Havells/Polycab] |
| 11 | Supply & Delivery 1.1KV grade AL/XLPE/SWA/PVC cable (Make - Polycab/Gloster/RR Cables) as per choice of EIC.2 Core 6 Sq mm. |
| 12 | Laying of 2Cx6sq.mm. XLPE/Ar. AL Cable on wall/surface incl. S&F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting, as per GS. |
| 13 | Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed |
| 14 | S&F compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of 2Cx6 sqmm XLPE/PVC armoured cable, as per GS. |
| 15 | Finishing the end of 2Cx6 sqmm XLPE/PVC armoured cable by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials, as per GS. |
| 16 | S&F of 250V double door Timer DB [equivalent of 2+8 way SPNDB] with sheet steel enclosure, pnosphitised powder coated neutral bar, DIN rail with IP-43 potection comprising with 1 no. 25A DPMCB (\"C\" curve 10KA), 2 no. 16A SPMCB (\"C\" curve 10KA), 1no. Programmable time switch-24 hrs with minimum switching of 15 minutes and 1 no. 18A/25A 2-Pole power contractor with inner-outer plate & internal wiring by suitable size of cu. wire incl. 1 no. Auto-Manual bypass toggle switch and provision for earthing attachment, incl. LED indication light for running condition with mechanical locking arrangement, as directed by EIC.[Make-ABB/L&T/Crabtree] |
| 17 | Supply of LED Tube illuminated sign board fabricated by 12\"\"(L)x4\"(H)x10\"(W) ACP box supported with 50 x 50 x 6 mm M.S. Angle structureall around with 40mm x40mmx 1.62 mm Al. edge angle for front portion only.The back side of the cover will be fabricated with hinges and arrangement in such a way so that it can be opened for maintenance purpose, including mechanical locking arrangement .The 3 mm ACP facial (Blue colour) should be provided with laser cutting of 6 mm laser cut Acrylic letters out of which 5 mm rising and back portion of the ACP board should be pasted with 2mm thick Clear Acrylic Sheet of same size as ACP facial as per the direction of EIC.The sign board should be illuminated by 18W LED Tube lamps (15 nos.)(Type- MAS LED Tube lamp 18 W 2100 lm) with Tube fittings (Phillips make) to be fixed by hooking arrangement with iron stucture fabricated for fixing purpose. Distribution wiring for power supply to LED fittings to be done by PVC rigid conduit, necessary clamps, cable tie etc. Back side of the of the board should be covered with 20 SWG G.I. sheet to protect rain water. The matter to be displayed will be finalised by authority and to be given later.This fabricated display structure is to be fixed on the top ofprefabricated iron structure as per direction of EIC. |
| 18 | The Rates to be quoted by all the bidders should be Inclusive of all taxes and duties including GST and LWC. |