| 1 | Taking down old unserviceablealuminium point wiring (light, fan, socket , power socket and bulk head fittings) from PVC/matelic conduit,on surface wiring, on wooden batten/casings & caping complete, including fixture and fittings such as switches, ceiling roses,pendents holder, regulators, sockets and defective main switch/DB/MCB/Metal plug etc. by unscrewing carefully from boards etccomplete all as specfied and directed. |
| 2 | M & L for point wiring for one light/one fan controlled by one switch with 1.5 sqmm single core PVC insulated unsheathed multistranded copper conductor (FRLS) with in and including PVC concealed conduit having thickness not less than 1.8 mm with all fittings including anodise pressed steel sunken box having thickness not less than 2mm with 3mm bakelite laminated sheet ISI marked for switches and sockets , including 1.5 sqmm single core PVC insulated unsheathed multistranded copper conductor (FRLS) as earth continuity conductor connected to comman earth dolly in and including cutting chiseling for concealed piping and making good disturbed surface area and white wash /colour wash to matching with the existing colour and all as specified and directed.Note: (a) Insulation test of point wiring (b) colour coding is to bemaintained .(Ph-Red, N-Black, Half -Yellow, Earth- Green) |
| 3 | All as per srl item No 2 above but for call bell point complete all as specified and directed. |
| 4 | All as per srl item No 2 above but for 3 pin 5 ampsindependent board completeall as specified and directed. |
| 5 | All as per srl item No 2 above but for 3 pin 5 amps on the sameboard with other switchcomplete all as specified and directed. |
| 6 | M & L for point wiring for one light/one fan controlled by one switch with 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductor (FRLS) with in and including PVC concealed conduit having thickness not less than 1.8 mm with all fittings including anodise pressed steel sunken boxand thickness not less than 2mm, including 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductor (FRLS) as earth continuity conductor connected to comman earth dolly in and including cutting chiseling for concealed piping and making good disturbed surface area and white wash /colour wash to matching with the existing colour and all as specified and directed.Note: (a) Insulation test of point wiring (b) colour coding is to bemaintained .(Ph-Red, N-Black, Half -Yellow, Earth- Green) |
| 7 | S & F for switch piano flush type one way 5 amps SP complete all as specified and directed. |
| 8 | Supply and fix bell push flush type with indicator 6 Amps complete all as specified and directed,. |
| 9 | S & F for switch piano flush type one way 15 amps SP complete all as specified and directed. |
| 10 | M & L for socket 2 in 1,3 pin, 6 and 16 Amp flush type universal complete all as specified and directed. |
| 11 | M & L for socket2 in 1,3 pin, 6 Amp flush type universal complete all as specified and directed. |
| 12 | M & L for ceiling rose 65 x 50mm three terminals complete all as specified and directed. |
| 13 | Supply and fixingelectronic bell ding-dong AC 230 Voltssingle polecomplete all as specified and diercted. |
| 14 | Supply and fixing ceiling fanregulator electronic type 5 stage speed variation,socket type is size, ISI marked complete all as specifiedanddirected. |
| 15 | S & Ffor lamp holder/batton holder/angle holder insulated body with back bakelite platesuitable for batten fittings complete all as specified and directed. |
| 16 | M& L for Inverter LED batten with square profile and polycarbonate channel,lithium Ion battery with charging time 8 hours to 10 hours and back up time upto 4 hours of capacity 20 watt 230 volt,complete with all accessories internally pre wired and including connecting up with three core twisted flexible copper conductor cable with suitable size mounting on rectangular PVC black complete all as specified and directed, |
| 17 | S&F LED TubeLight 20 wattLUMILINE Basic all purpose surface and wall mounted LED batten with polycarbonate housing and integrated electronic driver. complete inicluding taking down old one as directed . |
| 18 | Supply & fixing LED Bulk head Sirius Series10 W LEDlight . |
| 19 | S & F of sheet metal enclosures distribution boards, double door ,VTPN, 415 volts 4 ways (one incoming three phase & twelve out goings single phase )for MCCB & MCB,s comprising three phase four wire copper strip bus bar of appropriate capacitycomplete all as specified and directed and comprising of the following a) MCCB FOUR POLE 100 AMPS AC415 VOLTS16 KA=01 NO(for incoming )(b) MCB SP 63 amps = 04 Nos (for outgoings) . ( Note :- (i)TheDB shall be VTPN series. (ii) The DB shall be flush fixed and making good the disturbed surface matching with existing specifications shall be part of job at no extra cost.(iii)connection of the MCCBs/ MCBs with cableshall be made through appropriate size pin /bottle type thimble properly crimped.(iv)All the vacant holes of the DB shall be provided with blank plates of appropriate size. (v) Double continuous earth wire shall be provided for each three phase DB from earthing mains dolly. (vi) cutting chasing shall be part of job at no extra cost . |
| 20 | Supply and fixing sheet metal enclousre for TPN DBs 4 waywhen MCB to be used double door powder coated factory made flush fixed complete with 200 amps rated bus bar 240 volts three pahse and neuton 4 way complete all as specified and directed, |
| 21 | Supply and fixing sheet metal enclousre for DBs when MCB to be used double door powder coated factory made flush fixed complete with 200 amps rated bus bar 240 volts single phase 12 ways complete all as specified and directed. |
| 22 | Supply and fixing sheet metal enclousre for DBs when MCB to be used double door powder coated factory made flush fixed complete with 200 amps rated bus bar 240 volts single phase 08 ways complete all as specified and directed. |
| 23 | Supply and fixing for MCB TPN 63 amps 240 Volt \"B\" series complete all as specified and as directed. |
| 24 | Supply and fixing for MCB SPN 63 amps 240 Volt \"B\" series complete all as specified and as directed. |
| 25 | Supply and fixing for MCB SPN 6 to 32 amps 240 Volt \"C\" series complete all as specified and directed. |
| 26 | Supply and fixing for MCB SP 6 to 32 amps 240 Volt \"B\" series complete all as specified anddirected. |
| 27 | Taking down the unservicable /brunt sub main wiring from wooden batten and S & F forsubmain wiring in and including PVCconduit 1.8 mm thick ,25 mm dia with tworun of PVC insulated, unsheathed multistranded copper conductorof 6 sqmm(FRLS) and one run of PVC insulated,unsheathed multistranded copper conductor6 sqmm (green in colour) for earth continuity conductorand connected to common earth dolly withthimble etc, complete all as specified and directed. (Two run of 6 sqmm plus one run 6 sqmm of earth wire will be measured as 1RM)Note: (a) Insulation test of point wiring (b) colour coding is to bemaintained .(Ph-Red, N-Black,Earth- Green). |
| 28 | Taking down the unservicable /burnt sub main wiring from wooden batten and Supply & fixing forsubmain wiring in and including PVCconduit 1.8 mm thick ,32 mm dia with tworun of PVC insulated, unsheathed multistranded copper conductorof 10 sqmm(FRLS) and one run of PVC insulated,unsheathed multistranded copper conductor10 sqmm (green in colour) for earth continuity conductorand connected to common earth dolly withthimble etc, complete all as specified and directed. (Two run of 10 sqmm plus one run 10 sqmm of earth wire will be measured as 1RM)Note: (a) Insulation test of point wiring (b) colour coding is to bemaintained .(Ph-Red, N-Black,Earth- Green) |
| 29 | Earthing complete with galvanised steel earth plate electrode, 600mm x 600mm x 6mm thick, buried directly in theground (earth pit not less than 2.25m deep below normal (ground level) with top edge of the plate not less than 1.50m below ground level connected to galvanized iron wire 4mm diaas earth leadby means of bolts, nuts and washers of GIup to test point, GI tubing 15mm bore light grade protection pipe, GI watering pipe 20mm bore medium grade with funnel and wire mesh, charcoal and salt, 40mm thick pre-cast RCC (1:2:4) type B-0 (Nominal mix) cover reinforced with XPM (weighing n.less than 4 Kg/Sqm) with suitable steel handle, and angle iron 40X40X3mm frame and chamber of PCC (1:3:6) type C-0 (including earth work in any type of soil, removal of surplus soil to a distance n.exc.50m) and connecting, testing on completion, all as shown on electric plate No. 03 of SSR-2009 Part-I, complete all as directed.Notes: 1.Earth lead & protection pipes length upto & including 7.50 metre is included in the quoted rate.2.Soil should be free from stone, boulders, aggregate, gravels etc. |
| 30 | S & F in repair Recess mounting LED 2X2 luminaire light fitting complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of 1.5 Sq mm with suitable size of 36 watt complete all as specfied and directed. |
| 31 | S & F in repair surface mounting LED downlighter with white power coaled aluminium housing with integrated electronic driver 15 watt complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of 1.5 Sq mm with suitable size of 40/42 watt complete all as specfied and directed. |
| 32 | S & F in repair Round shape 18 watts 220 volts AC, recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed. |
| 33 | S & F ofstreet light fitting made up of pressure die cast aluminium housing with IP65 protectionof 35 watts LED Cool Daylight complete fitted on bldg with suitable dia of GI pipe medium grade 1.5in length long with suitable size of 2 nos MS flat clamps FI 25 x 3 mm including nuts,bolts including connecting up with PVCcopper conductor wire 1.5 sqmm s/c from security light to ceiling rose etc, complete all as specified and directed, |
| 34 | Supply and Replacement of MCCB 4 pole 440 volt 125 Amp rating capacity in 36 KA complete all as specfied and directed. |
| 35 | Supply and Replacement of MCCB 4 pole 440 volt 160 Amp rating capacity in 36 KA complete all as specfied and directed. |
| 36 | supply and fixing 1100 volts gradePVCinsulated heavy duty armoured multistrandedaluminium conductor,served with inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire,one twin core cable flat or circular 10sqmm 2 core. |
| 37 | Supply and fixing switch modular 6amps 230 volts one way switch. |
| 38 | S&Fsocket 6Amps AC 230 VOLTS 2/3 pin combined 2 modular type complete all as specfied and directed. |
| 39 | S&Fsocket 6A/16Amps AC 230 VOLTS 2/3 pin combined 2 modular type complete all as specfied and directed. |
| 40 | Supply and fixing switch modular 16amps AC230 volts one way switch complete all as specfied and directed. |
| 41 | Supply and fixingModular white cover plate with frame 2 module and metal flush box 2 module complete all as specfied and directed. |
| 42 | Supply and fixing modular fan regulator step type120W-2module |
| 43 | Supply and fixingModular white cover plate with frame 2 module and metal flush box 1/2 module complete all as specified and as directed. |
| 44 | Supply and fixingModular white cover plate with frame 3 module and metal flush box 3 module complete all as specified and as directed. |
| 45 | Supply and fixingModular white cover plate with frame 4 module and metal flush box 4 module complete all as specified and as directed. |
| 46 | Supply and fixingModular white cover plate with frame 6 module and metal flush box 6 module complete all as specfied and directed. |
| 47 | Supply and fixingModular white cover plate with frame 8 module and metal flush box 8 module complete all as specfied and directed. |
| 48 | Supply and fixingmodular Bell push 6amps 230 volts 1 module |
| 49 | Note :- The contract sum shall be arrived at after deduction of amount of sch of credit |