| 1 | Scaffolding charges for Vimanams and Gopurams with casurina posts coconut or palm trees wherever necessary for main, form work and providing with net lawn / PVC mesh coverings, providing ladder arrangements, country wood plank for working, inspection etc. complete, hire charges only for erection, maintenance and removing the same on completion of the work. |
| 2 | Entrance Raja Gopuram upto 50 feet ht |
| 3 | Vimanam Upto 25 feet ht |
| 4 | Vimanam Upto 15 feet ht |
| 5 | Painting with multicolour (Panchavarnam)goodemulson paints complete for the Vinamans/Gopurams, including costand conveyance of all materials, lobour charges including Artist painter, working in heights, lifting of material, cost of brushes etc,complete-which including all extra for foldings-100sft, superficial area. |
| 6 | Entrance Raja Gopuram upto 50 feet ht |
| 7 | Vimanam Upto 25 feet ht |
| 8 | Vimanam Upto 15 feet ht |
| 9 | Water washing the stone surfaces restoration by providingwater jet wash using appropriate methodology with lite tespal liquid ammonia to restore the originalities of the existing granite structure inclusive of hire charges of all tools and plants employed, scaffolding arranements, conveyence charge of all materials to site andlabour for work etc.,completed as per standard specification. |
| 10 | Labour charges for Pointing the Cut stone Masonary work with Lime Mortar 1:1.5 excluding cost and conveyance of cut stone but including all labour charges scaffolding etc.,complete with standard specifications. The lime used should be sourced from pollachi which is highly iron fortified and suitable for structural and masonary works.(wall) |
| 11 | Dismantling, clearing away and carefully stacking materials useful for re-use for any thickness of wallsBrick / Stone in Clay Walls under 3m high etc.,complete |
| 12 | Earthwork excavation for foundation in all soils except hard rock requiring blasting to a full depth with intial lead of 10m and lift of 2m etc.,comple |
| 13 | Supplying and filling in foundation, basement, etc with filling M- sand in layers of not more than 150 mm thick well watered, rammed and consolidated complying with relevant std specification including cost of supplying filling M-sand |
| 14 | Cement Concrete 1:5:10 (One Cement, Five M-sand and Tenof HBG jelly) for foundation using 40 mm gauge HBG jellyinclusive of shoring strutting and bailing out water where ever necessary ramming curing etc.,complete as per std specification and as directed by the dept,officers |
| 15 | Random Rubble masonry work in CM 1:5 ( One of cement and five of M-sand) Using selected stones and bond stones in foundation and basement including dewatering wherever necessary proper setting, curing etc., complete in all respectscomplying with relevant standard Specifications. (Foundation and Basement) |
| 16 | Centering for sides and soffits of Rcc slabs of plain surface like lintels, beams, etc., including strutting 3M hight using MS sheets of size 90cmx60cm and BG 10 stiffened with MS angles of size 25x25x3mm laid over silver oak (C.W) joists of size 10x6.5cm (spaced at about 90cm c/c) and supported by casurina prop. 10cm to 13cm dia ( spaced of 75cm c/c) complying with standard specification and directed by the Dept, Officers. 10sqm. |
| 17 | Grade beam Below Ground level |
| 18 | Lintel Level Beam |
| 19 | Providing and laying position,Standardised concrete mi M-20 Grade in accordance with IS :456-2000,using 20mm and down graded hard brocken granite stone jelly for all Rcc items of works with minimum cement content of 3250 kg/cum and maximum water cement ratio of 0.55,inculding admiture (plasticiser / super plasticiser) in recommendedproportions as per IS:9103 to accelerate, retart setting of concrete, improve workablity without imparingstrenghanddurability with about(5 cum)7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m)5156 kg of 10-12 mm machine crushed stone jelly and with about(4.79 cu.m)7670 kg of M-sand ,but eculding cost of reinforcement grill and fabricatingcharges,centering and shuttering and also inculding laying, vibrating with mechanical vibrtors,finishing,curing,etc,complete complying with standred specification and ass directed by the departmentel officers.the coarse and fine aggregates to be used shoul comply with the requirments of IS standreds.(No separate payment will be made by the Department for the excess usageof materials.) |
| 20 | Foundation and basement level |
| 21 | Above ground level |
| 22 | Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification.(Contractor has to make his own arrangements for the supply of steel and binding wire) |
| 23 | Brick work in Cement Mortar 1:5 using 2nd class ground moulded Chamber brickssize8 3/4\" x 4 3/8\" x 2 3/4\" including cost and conveyance of all materials and labour charges and all other incidental charges etc completc complying with standard specification. |
| 24 | Foundation and basement level |
| 25 | Superstructure level |
| 26 | Plastering with Cement mortar 1:5,12mm thick including cost and conveyance of all materials and all labour charges, curing etc,complete complying with standard specifications. |
| 27 | Special plastering of RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three Plastering Sand) 10mm thick including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the departmental officers |
| 28 | Painting two coat with approved water based Exterior Emulsion over the cement plastered wall surface, ceiling and other new surface including clearing preparing the surface curingin all floors including brushes etc., complete as per specification. |
| 29 | Supplying and fixing of mild steel grill gate including cost and conveyance of all materials and fixing in postion including priming coat etc complete with standard specification |
| 30 | Painting new iron works such as gates, steel doors, windows, ventilatorswith two coats of approved quality and colour of synthetic enamel paint over the existing red oxide primerin all floors etc., complete complying with standard specification. With one coat Zinc Chormide paint over the exisiting priming coat |
| 31 | Providing new sudhai vigrahams in the vimanams and Rajagopurams with Copper rod reinforcement of suitabledia with binding wires wherever necessary, shaping the core with broken bricks set in LM 1:1:3 finishing the same with LM 1:1:3bringing to the correct shape (Lakshana) in conformist with silpa sastra inclusive of special ornaments, weapons, peedam etc., complete and providing L.M. Nayam theervai wherever necessary. inclusive of cost and conveyance of all materials, such as cement broken bricks, and Copper rods. binding wire all labour for working in heights, curing lifting of materials etc., complete including Exterior Emulsion painting 2 coats over a primary coat(one vigraham is accountable with one head, 4 hands with weapons, ornamental costumes etc., as per prathima lakshans, Vigraham height is measurable from the crown top to the bottom of foot only If peetam is provided the rate with peetam may be adopted as detailed hereunder) |
| 32 | Sudhai Size above 3\"6\" upto 4\"6\" |
| 33 | Sudhai Size above 4\"6\" upto 5\"6\" |
| 34 | Flooring with cut stone slab of size 600mmX600mm and other sizes suitable for site requirement not less than 100mm thick with machine cut edges and top surface dressed as directed by the departmental officers including cost and conveyance of materials to site and lobour charges for paving and Pointing With Cement Mortar 1:5 & Combination Mortor1:1:5 etc complete. |
| 35 | Supplying & fixing Teak wood temple type door including all materials, labour charges for manufacturing and fixing in position including all furniture fittings etc complete with std. Specifications |
| 36 | Size of 4\"0\" X 7\"0\" |
| 37 | Size of 3\"0\" X 6\"0\" |
| 38 | Size of 7\"0\" X 11\"0\" |
| 39 | Wiring with 2 x1.5 sq.mm.PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigidpipe on wall and ceiling with PVCaccessories with Module GI switch boxin flush with wall with 6A one way module switch with module front plate withcontinuous earth wire connection of 1.5 sq.mm copper wire with painting of Suitable colourforOpen PVCLight point / fan point (for electronic regulator) ( 5 points / Coil) Lower End (for RCC Mandapam) |
| 40 | Wiring with 2 x1.5 sq.mm. (22/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in existing powder coated duct with Module GI switch box in flush wall with 6A one way module switch with module front plate with painting of Suitable colour for Open Light point / fan point (for electronic regulator) (5 points / Coil) Higher End |
| 41 | Supply and fixing of 4\" 20W LED battern on wall or ceiling or existing duct with copper leads from fittings to Terminals |
| 42 | Supply and fixing of 7W/9W LED for BH point. |
| 43 | Supply and fixing of 22W LED Round Surface type fitting with necessary accessories and electrical connections complete. |
| 44 | Supply and run of 5 core 2.5 sq.mm flexible copper wire with necessary accessories with electrical connections complete. |
| 45 | Supply and fixing of 375 mm (15\") sweep (Heavy duty) AC Exhaust fan complete without provision |
| 46 | Supply and fixing of louvers shutters arrangements for 375mm (15\") sweep (light duty) AC exhaust fan |
| 47 | Supply and fixing of 450mm 18\" Almonard Wall Fan with Pillar Clamp 1½ x ¼ MS flat with bolt and nuts for fixing the Fan on pillar with necessary connection. |
| 48 | Supply and run of 35mm x 20mm powder coated duct with door arrangements complete with MS angle and bolt & nuts complete |
| 49 | Supply and run of 35mm x 45mm powder coated duct with door arrangements complete with MS angle and bolt & nuts complete. |
| 50 | Supply and run of MS at for clamps of size 2\"x l\" on pilla with suitable Bolt / nuts and painting of suitable colour. |
| 51 | Supply and run of 2 of 4 sq.mm. (22 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V grade on wall and ceiling in existing powder coated duct with continuous earth wire connection 1.5 sq.mm copper wire. |
| 52 | Supply and Run of 2 of 2.5 sq.mm. (36/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade on wall and ceiling or in existing powder coated duct with continuous earth wire connection of 1.5 sq.mm copper wire. |
| 53 | Supply and fixing of 2 nos.6A two module 5 pin socket, 2 nos.6A one module switch on suitable module surface mounting Box(Plastic) with module cover plate (plastic) on wall with connections. Higher End (Set plug) |
| 54 | Supply and fixing of 1 no.6/16A two module socket, 1 no. 16A one module switch on suitable module surface mounting Box (Plastic) with module cover plate (plastic) on wall with connections. Higher End |
| 55 | Supply and fixing of 30W LED focus fitting complete on suitable MS angle with suitable MS clamp. (For Urchavar andGuru Bhagavan sannadhi outer) |
| 56 | Supply and fixing of 100W LED Focus / Flood light fitting complete with 1\" dia GI pipe supports between the walls with suitable MS clamps, painting and electrical connections complete. |
| 57 | Supply and fixing of sintex box (SMC) with 1 no. 6-32A SPMCB, 16A bakelite connector on a hylem sheet with inter connections complete. (For street lights / focus / flood lights) |
| 58 | Supply and fixing of 8 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB switch as incoming and 6 nos. 6A to 32A SP MCB as outgoing on suitable angle iron frame on wall with earth connection only. Higher End |
| 59 | Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB switch as incoming and 10 nos. 6A to 32A SP MCB as outgoing on suitable angle iron frame on wall with earth connection only. Higher End |
| 60 | Supply and fixing of 63A 4 way Vertical Triple pole and neutral MCB sheet steel enclosure distribution board withdouble door (metal) with 1 no. 63A 4P MCB Isolator as incoming and 12 nos. 6A to 32A SP MCB as outgoing on suitable angle iron frame on wall with earth connection only.Higher End |
| 61 | Supply, Erection, testing and commissioning of 125 A capacity dust and vermin proof horizontal type cubical panel board made up of 16 SWG CRCA Sheet with supply and fixing of the following interior switches with HRC fuse links arranged horizontally with horizontal busbar chamber and cable chambers.1. 125A TPN Switch interior with HRC fuses - 1 nos2. 63A TPN Switch interior with HRC fuses -2. Nos.3. 32A TPN Switch interior with HRC fuses -4 Nos.The busbar chamber shall consist of 4 Nos 25mm x 3mm copper and neutral and interconnection between incoming switch and buses. The 25mm x 3mm copper flat for interconnection between TPN switches to buses. 25mm x 3mm copper flat buses shall be mounted on SMC busbar insulator at proper and sufficient interval as per IE rules. The busbar chamber shall be segregated from the adjacent chamber. The heat shrinkable sleeves shall be provided for busbar with colour code. The 25mm x 3mm copper flat for double earth connection for all incoming and outgoing switches are to be provided in this panel. The panel shall have powder coated painting of approved colours, approved by the department officers. The danger board shall be fixed at front of panel board.The panel shall be mounted on MS base channel provided all round at the bottom of the panel. The whole arrangements shall be erected on a Masonary pedestal to be constructed with suitable foundation with bolts and nuts such that the lowest SDF unit fuse handle is at a height of 0.75m from the ground level. |
| 62 | Supply and Laying of 3½ x 25 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. |
| 63 | Supply and clamping of 3½ x 25 sq.mm PVC LTUG armoured Alu cable on post or on wall with MS Clamps. |
| 64 | Supply and fixing of brass cable gland for 3½ x 25 sqmm PVC armoured LTUG cable with earth connection. |
| 65 | Supply and providing cable end termination of 3½ x 25 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete |
| 66 | Supply and Laying of 4 x 10 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. |
| 67 | Supply and clamping of 4 x 10 sq.mm PVC LTUG armoured Alu cable in on post or on wall with MS Clamps. |
| 68 | Supply and fixing of brass cable gland for 4 x 10 sqmm PVC amoured LTUG cable with earth connection. |
| 69 | Supply and clamping of 2 x 10 sq.mm PVC LTUG armoured Alu cabie in on post or on wall with MS Clamps |
| 70 | Supply and fixing of brass cable gland for 2 x 10 sqmm PVC armoured LTUG cable with earth connection. |
| 71 | Supply and fixing of 48W LED street light fitting with LED (Higher end) with 32mm dia. GI pipe (class B) with 1 no.32 mm GI bend complete on the existing post/ on wall with PVC unsheathed copper leads with MS clamps and with painting |
| 72 | supply and fixing of 65 mm dia. (2 -1/2\") GI pipe (class B) of 6 metre length with 300mm x 300mm x 6mm MS base plate duly welded at the bottom with concreting with construction of masonary pedestal with suitable SMC box with door arrangement to house 6A SP MCB switch, 2/4 way connector on suitable hylem sheet and supply and fixing of 48W LED street light fitting with LED (Higher end) with 1 metre 32mm dia. GI pipe (class B) Complete with suitable MS clamps for LED steet light fitting and SMC box with PVC unsheathed copper leads from SMC box to fitting and with painting of suitable colour |
| 73 | Supply and fixing of 3 x 150W LED street light fitting complete with 9 Metre Length Double Bracket Pole with Base Plate (300 x 300 x 6mm) (SR pg no. 149, item no 1-n) 114.30mm OD x 5.40mm Thick x 5000mm Length, 88.90mm OD x 4.85mm Thick x 2000mm Length, 76.10mm OD x 3.25mm Thick x 2000mm Length complete with concreting and Masonary work for fixing the sintex box with hemispherical top cover with 4\" x 4\" junction box with IP 67 protection with PVCunsheathed copper leads in flexible green hose, MS clamps and aluminium painting |
| 74 | Supply and fixing of 125A (500V) three phase meter box fabricated with 16 SWG CRCA Sheet comprising of with 3 nos. of 200A fuse units, 1 no. neutral link, 1 no. 125A TPN SDF, provision for fixing TNEB meter with inter connections and with required accessories on wall complete. |
| 75 | Supply and fixing of 100A three phase 500V 4 pole change over switch on suitable angle iron frame work with M.S copple entry sources with earth connenctions |
| 76 | Supply erection, commissoning and testing of 58.5 KVA Diesel generator with acoustic arrangements in accordance with CPCB norms, water / coolant oil cooled type engine with 90 BHP at 1500 rpm under NTP conditions with following specifications. The engine should have turbo charged, should be provided with air cleaner, base frame, crank case, lubricating oil, fan and fan drive, fuel and oil filters, flexible fittings, exhaust governor, hydro-mechanical gauges for fuel pressure and oil pressure, tachometer, digital water temperature gauge, charging arms, muffler, exhaust pump for fuel priming, fuel transfer, jacket with radiator engine oil, safety set ups with engine shutdown system for LLOP including the set of tools, spares as supplied by the manufacturer along with the Engine. The altemator should have brushless self-excited Y connected, self-regulated of continuous rating, developing an output of 24KW at 0.8 power factor lagging, 415 V, 3 phase, 50 Hz at 1500 rpm with a voltage regulation of +1 % under steady state condition with over speed capacity of 10% for 5 minutes withstanding capacity with class H insulation, ingression protection of IP23 with topicalization. The alternator is to be designed, built & tested to IS, BS, IEC or any other equivalent Indian or International Standards.The engine should be provided with suitable electrical starting system including, suitable radiator arrangements with suitable fully charged new batteries and with other connecting accessories. microprocessor based genset controllers display and displayed at phase voltage & currents, Frequency, reverse Power, Genset KVA, KW, KWh, KVAr, power factor, canopy teniperature, lube oil pressure,engine temperature, RPM, run hours, number of starts, fuel level, auto / manual stop, battery charge condition. The fuel tank should be fabricated with 14 SWG CRCA MS sheet steel inbuilt removable type sheet metal fuel tank with fuel gauge drain plug and fuel connections, fuel level indicator and with a capacity of not less than 75 Ltrs.Provisions are to be made to filter the sediments, water in the fuel at rear side and provision of vent at top to release the air pressure in the tank. The tank should be painted with noncorrosive and non-flammable paint. The fuel tank should be filled with a minimum level of fuel for test running on full load. The genset should be placed on a concrete bed of suitable dimensions as per PWD standards. |
| 77 | Earthing as per the ISI specification with an earth electrode of 2.10 metre Class \"B\" GI pipe of dia not less than 40mm with copper earth plate of size 125mm x 50mm x 6mm with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry |
| 78 | Supply and run of 25mm x 3mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection |
| 79 | Supply and Run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe on wall / floor / ground for earth connection |
| 80 | Sub Total |
| 81 | GST @ 18% |