Tender For Electrification Work Of Sainik Kalyan And Rehabilitation Office Rest House And Houses In District Auraiya - Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.GROUP B 3 Light Point 4 Call Bell Point 5 Fan /Fresh Air Point 6 Exhaust Point 7 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. 8 Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 9 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 10 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 11 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 12 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 13 2 X 10 sq. mm + 1 X 6 sq. mm earth wire 14 4 X 16 sq. mm + 2 X 6 sq. mm earth wire 15 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 16 1 x 1.5 sq. mm 17 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. 18 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 19 20 mm 20 Supplying and fixing of following Moduler Switch/Socket on the exiting modular plate & Switch box including connection but excluding modular plate etc. as required. 21 TV Antena socket outlet 22 Supplying and fixing following size/modules GI Box along with moduler base & cover plate for modular switches in recess etc as required. 23 1 or 2 module (75mm x 75mm) 24 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. 25 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc as required. 26 Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 27 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc as required. 28 Supplying and fixing PVC batten/angle holder including connections etc. as required. 29 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. 30 12 way, Double door 31 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc as required.(But without MCB/RCCB/Isolator) 32 4 way (4 + 12), Double door 33 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 34 Single pole 35 Double pole 36 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 37 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 38 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required. 39 3 1/2 X 50 sq. mm (35mm) 40 4 X 16 sq. mm (28mm) 41 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS: 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise-75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 42 Supply and Laying of Al. Conductor PVC Insulated armoured served sheathed cable 1100V grade a depth of 750mm below ground level over a cushion of 75mm thick sand all around and protected with brunt bricks on sites and on top as directed by EnC complete in all respect including excavation and refilling. The armoured of the cable shall be properly connected with the earth coductor by clamps etc. 43 50sq mm 3½ core 44 SITC of LT Panelvermin proof floor mounting ,M.S. channel base with bottom and Fabricated out of 2.0/1.6mm thick CRCA sheet steel, painted with powder coated paint of shade as per the direction of Engineer In-Charge after proper sheet treatment process of sheet steel. The Bus Bar of panel shall be of Electrical grade High Conductive Aluminum alloy of appropriate cross section as per rating.The main bus bar shall run throughout the panel of rating as main incomer rating.The Bus Bar shall be supported by non hygroscopic SMC/DMC Bus Bar supports which shall be mounted on proper interval to ensure the bear the jerks of short Circuit of 50kA for panels having ACB as Incomer & 36kA for panels having MCCB Incomers. Panel shall be constructed in fully Segregated Compartment Design for Each Feeder as per 3b construction Format. The Panel shall be completed in all respect as per IS: 8623 Part-2&3. There shall be Separate Metering Compartment for incomer metering and outgoing metering.All Incomer Feeders shall be provided with Multifunction Metering along with Phase Indicating Lights and other associated components such as CT, control MCB Terminal Block etc. and all Outgoing Feeders 100A & above shall be provided with 3 phase Ammeter along with phase Indicating Lights and other associated components such as CT, control MCB Terminal Block etc. The Feeders above shall be provided ac accommodated all Measuring Instruments shall be Digital type & all Indicating Lights shall be LED type. Wiring shall be done from 1100V Grade PVC Insulated copper flexible wire. All ACB shall be Electrically operated Draw-out type with Microprocessor Based O/L, S/C & E/F Release of Breaking/ Withstand Capacity (ICU/ICs/Icw) 50kA or more All MCCB shall be Thermal Magneetic/Microprocessor with O/L & S/CProtection along with Required Spreaders & Extended Rotary Handle with pad Locking facility of Breaking capacity (ICU/ICS) 36kA or more All MCB shall be Thermal 10kA C Curve. Cubicle type switch board shall be Cat-A and B only.Incoming 100 AMP MCCB 01 No.Outgoing 63 AMP MCCB 02 No. 45 Supply and fixing of IP20, Front Lit, Mid Power SMD type LED Light, recess/Surface mounting round 18 Watt to 20 Watt, Cutout Min 150mm, Height Min 40mm,, LED Down Lighter having Powder coated die cast aluminium housing with heat sink, High purity / transmisivity UV Stabilized Non yellowish diffuser/ Reflector for uniform light distribution, detachable driver set, suitable for 24 Hr Continuous Operation, Complete in All respect. 720-1080systemlumens,>120Lm/W, PF>0.95,THD<10%at full load, CRI >80, >300Vover voltage protection, 2.5KV internal Surge Protection, with 5 years warrantee 46 Supply and fixing of LED Tube Light with heavy duty Metal Box type Tube Light fitting 1x22 watt suitable for upto 1x 22 watt LED Polycarbonate tube light complete Including tube suitable for both surface & suspended complete in all respect. (2620 systemlumens, >120Lm/W, PF>0.95, THD<10%, CRI >80, sheet thickness min 0.8mm,Tube with aluminium heat sink, >300 Vover voltage protection, 2.5KV internal Surge Protection, with 5 year warrantee.) 47 Supply of Heavy Duty Exhaust Fan 300 mm. sweep 900 RPM Single phase complete in all respect. Havells or Eq. 48 Supply of Metallic body fresh air fan 300 mm. sweep complete in all respect. Havells or Eq. 49 Supply and fixing of 7 Watt LED Bulb Output 630 Lm, Color Temp 300 k 0.04 Amp. Havells or Eq. 50 S/f of fire extinguisher ABC type 4.0 Kg capacity complete with initial charges and wall bracket alnong with supply of all material and lobour 51 S/f of fire extinguisher Co2 type 4.5 Kg capacity complete with initial charges and wall bracket alnong with supply of all material and lobour 52 Supply of Decorative wall Light fixtures made of polycarbonate suitable for 9 watt LED bulb B22 base LED Lamp complete in all respect. Havells or Eq. 53 Supply and fixing of 63 Amp. FP MCB (10 KA) 240 V/415 V, 50 Hz,Legrand or Eq. 54 S&F of L&t Changeover Switch 4 Pole 100amp 415v. 55 PART B (Office Building) 56 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.GROUP C 57 Light Point 58 Call Bell Point 59 Fan /Fresh Air Point 60 Exhaust Point 61 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. 62 Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 63 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 64 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 65 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 66 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 67 2 X 10 sq. mm + 1 X 6 sq. mm earth wire 68 4 X 16 sq. mm + 2 X 6 sq. mm earth wire 69 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. 70 1 x 1.5 sq. mm 71 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. 72 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. 73 Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 74 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc as required. 75 Supplying and fixing PVC batten/angle holder including connections etc. as required. 76 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. 77 12 way, Double door 78 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 79 4 way (4 + 12), Double door 80 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 81 Single pole 82 Double pole 83 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 84 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 85 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required. 86 4 X 16 sq. mm (28mm) 87 3 1/2 X 50 sq. mm (35mm) 88 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS: 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise-75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 89 Supply and Laying of Al. Conductor PVC Insulated armoured served sheathed cable 1100V grade a depth of 750mm below ground level over a cushion of 75mm thick sand all around and protected with brunt bricks on sites and on top as directed by EnC complete in all respect including excavation and refilling. The armoured of the cable shall be properly connected with the earth coductor by clamps etc. 90 50sq mm 3½ core 91 Supply, Installation,Testing amd Commissioning of LT Panelvermin proof floor mounting ,M.S. channel base with bottom and Fabricated out of 2.0/1.6mm thick CRCA sheet steel, painted with powder coated paint of shade as per the direction of Engineer In-Charge after proper sheet treatment process of sheet steel. The Bus Bar of panel shall be of Electrical grade High Conductive Aluminum alloy of appropriate cross section as per rating.The main bus bar shall run throughout the panel of rating as main incomer rating.The Bus Bar shall be supported by non hygroscopic SMC/DMC Bus Bar supports which shall be mounted on proper interval to ensure the bear the jerks of short Circuit of 50kA for panels having ACB as Incomer & 36kA for panels having MCCB Incomers. Panel shall be constructed in fully Segregated Compartment Design for Each Feeder as per 3b construction Format. The Panel shall be completed in all respect as per IS: 8623 Part-2&3. There shall be Separate Metering Compartment for incomer metering and outgoing metering.All Incomer Feeders shall be provided with Multifunction Metering along with Phase Indicating Lights and other associated components such as CT, control MCB Terminal Block etc. and all Outgoing Feeders 100A & above shall be provided with 3 phase Ammeter along with phase Indicating Lights and other associated components such as CT, control MCB Terminal Block etc. The Feeders above shall be provided ac accommodated all Measuring Instruments shall be Digital type & all Indicating Lights shall be LED type. Wiring shall be done from 1100V Grade PVC Insulated copper flexible wire. All ACB shall be Electrically operated Draw-out type with Microprocessor Based O/L, S/C & E/F Release of Breaking/ Withstand Capacity (ICU/ICs/Icw) 50kA or more All MCCB shall be Thermal Magneetic/Microprocessor with O/L & S/CProtection along with Required Spreaders & Extended Rotary Handle with pad Locking facility of Breaking capacity (ICU/ICS) 36kA or more All MCB shall be Thermal 10kA C Curve. Cubicle type switch board shall be Cat-A and B only.Incoming 100 AMP MCCB 01 No.Outgoing 63 AMP MCCB 02 No. 92 Supply and fixing of IP20, Front Lit, Mid Power SMD type LED Light, recess/Surface mounting round 18 Watt to 20 Watt, Cutout Min 150mm, Height Min 40mm,, LED Down Lighter having Powder coated die cast aluminium housing with heat sink, High purity / transmisivity UV Stabilized Non yellowish diffuser/ Reflector for uniform light distribution, detachable driver set, suitable for 24 Hr Continuous Operation, Complete in All respect. 720-1080systemlumens,>120Lm/W, PF>0.95,THD<10%at full load, CRI >80, >300Vover voltage protection, 2.5KV internal Surge Protection, with 5 years warrantee 93 Supply and fixing of LED Tube Light with heavy duty Metal Box type Tube Light fitting 1x22 watt suitable for upto 1x 22 watt LED Polycarbonate tube light complete Including tube suitable for both surface & suspended complete in all respect. (2620 systemlumens, >120Lm/W, PF>0.95, THD<10%, CRI>80, sheet thickness min 0.8mm,Tube with aluminium heat sink, >300 Vover voltage protection, 2.5KV internal Surge Protection, with 5 year warrantee.) 94 Supply of Metallic body fresh air fan 300 mm. sweep complete in all respect. Havells or Eq. 95 Supply and fixing of 7 Watt LED Bulb Output 630 Lm, Color Temp 300 k 0.04 Amp. Havells or Eq. 96 S/f of fire extinguisher ABC type 4.0 Kg capacity complete with initial charges and wall bracket alnong with supply of all material and lobour 97 S/f of fire extinguisher Co2 type 4.5 Kg capacity complete with initial charges and wall bracket alnong with supply of all material and lobour 98 Supply and fixing of 63 Amp. FP MCB (10 KA) 240 V/415 V, 50 Hz,Legrand or Eq. 99 S&F of L&t Changeover Switch 4 Pole 100amp 415v. 100 PART C (Type-1 Residence (2 No. Residence) ) 101 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.GROUP A 102 Light Point 103 Call Bell Point 104 Fan /Fresh Air Point 105 Exhaust Point 106 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. 107 Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required 108 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 109 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 110 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 111 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 112 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. 113 1 x 1.5 sq. mm 114 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. 115 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 116 20 mm 117 Supplying and fixing of following Moduler Switch/Socket on the exiting modular plate & Switch box including connection but excluding modular plate etc. as required. 118 TV Antena socket outlet 119 Supplying and fixing following size/modules GI Box along with moduler base & cover plate for modular switches in recess etc as required. 120 1 or 2 module (75mm x 75mm) 121 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. 122 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. 123 Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 124 Supplying and fixing PVC batten/angle holder including connections etc. as required. 125 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. 126 8 way, Double door 127 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 128 Single pole 129 Double pole 130 S/F of Double pole Sheet Steel Enclosure on a surface/recess along with 25/32 Amp 250 Volt C Curve Double pole MCB Complete with connection, testing & Commissioning extra as required. 131 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 132 Providing & Fixing 6 SWG dia G.I. Wire on surface on in recess for loop earthing as required. 133 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS: 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise-75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 134 Supply and fixing of LED Tube Light with heavy duty Metal Box type Tube Light fitting 1x22 watt suitable for upto 1x 22 watt LED Polycarbonate tube light complete Including tube suitable for both surface & suspended complete in all respect. (2620 systemlumens, >120Lm/W, PF>0.95, THD<10%, CRI>80, sheet thickness min 0.8mm,Tube with aluminium heat sink, >300 Vover voltage protection, 2.5KV internal Surge Protection, with 5 year warrantee.) 135 Supply of Heavy Duty Exhaust Fan 300 mm. sweep 900 RPM Single phase complete in all respect. Havells or Eq. 136 Supply of Metallic body fresh air fan 300 mm. sweep complete in all respect. Havells or Eq. 137 Supply of Decorative wall Light fixtures made of polycarbonate suitable for 9 watt LED bulb B22 base LED Lamp complete in all respect. Havells or Eq. 138 Supply and fixing of 7 Watt LED Bulb Output 630 Lm, Color Temp 300 k 0.04 Amp. Havells or Eq. 139 PART D (Type-2 Residence (2 No. Residence) ) 140 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.GROUP A 141 Light Point 142 Call Bell Point 143 Fan /Fresh Air Point 144 Exhaust Point 145 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. 146 Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 147 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 148 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 149 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 150 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 151 2 X 16 sq. mm + 1 X 6 sq. mm earth wire 152 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 153 1 x 1.5 sq. mm 154 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. 155 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 156 20 mm 157 Supplying and fixing of following Moduler Switch/Socket on the exiting modular plate & Switch box including connection but excluding modular plate etc. as required. 158 TV Antena socket outlet 159 Supplying and fixing following size/modules GI Box along with moduler base & cover plate for modular switches in recess etc as required. 160 1 or 2 module (75mm x 75mm) 161 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. 162 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. 163 Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 164 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required. 165 Supplying and fixing PVC batten/angle holder including connections etc. as required. 166 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. 167 12 way, Double door 168 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 169 Single pole 170 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 171 Providing & Fixing 6 SWG dia G.I. Wire on surface on in recess for loop earthing as required. 172 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS: 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise-75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 173 Supply and fixing of LED Tube Light with heavy duty Metal Box type Tube Light fitting 1x22 watt suitable for upto 1x 22 watt LED Polycarbonate tube light complete Including tube suitable for both surface & suspended complete in all respect. (2620 systemlumens, >120Lm/W, PF>0.95, THD<10%, CRI>80, sheet thickness min 0.8mm,Tube with aluminium heat sink, >300 Vover voltage protection, 2.5KV internal Surge Protection, with 5 year warrantee.) 174 Supply of Heavy Duty Exhaust Fan 300 mm. sweep 900 RPM Single phase complete in all respect. Havells or Eq. 175 Supply of Metallic body fresh air fan 300 mm. sweep complete in all respect. Havells or Eq. 176 Supply and fixing of 63 Amp. DP DX AC MCB (10 KA) 415 V, 50 Hz, Legrand or Eq. 177 Supply of Decorative wall Light fixtures made of polycarbonate suitable for 9 watt LED bulb B22 base LED Lamp complete in all respect. Havells or Eq. 178 Supply & Fixing of Metal Enclosure for Independent Mounting of MCB RCCB, RCBO and DPX3 MCCBs (DP Enclosure & Four Pole Enclosure), Legrand or Eq. 179 Supply and fixing of 7 Watt LED Bulb Output 630 Lm, Color Temp 300 k 0.04 Amp. Havells or Eq. 180 PART E (Type-4 Residence) 181 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group B 182 Light Point 183 Call Bell Point 184 Fan /Fresh Air Point 185 Exhaust Point 186 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. 187 Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 188 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 189 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 190 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 191 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 192 4 X 16 sq. mm + 2 X 6 sq. mm earth wire 193 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required. 194 1 x 1.5 sq. mm 195 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. 196 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 197 20 mm 198 Supplying and fixing of following Moduler Switch/Socket on the exiting modular plate & Switch box including connection but excluding modular plate etc. as required. 199 TV Antena socket outlet 200 Supplying and fixing following size/modules GI Box along with moduler base & cover plate for modular switches in recess etc as required. 201 1 or 2 module (75mm x 75mm) 202 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. 203 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. 204 Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 205 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc as required. 206 Supplying and fixing PVC batten/angle holder including connections etc. as required. 207 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 208 12 way, Double door 209 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. 210 4 way (4 + 12), Double door 211 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 212 Single pole 213 Double pole 214 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 215 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 216 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 217 4 X 16 sq. mm (28mm) 218 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS: 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise-75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 219 Supply and fixing of IP20, Front Lit, Mid Power SMD type LED Light, recess/Surface mounting round 18 Watt to 20 Watt, Cutout Min 150mm, Height Min 40mm,, LED Down Lighter having Powder coated die cast aluminium housing with heat sink, High purity / transmisivity UV Stabilized Non yellowish diffuser/ Reflector for uniform light distribution, detachable driver set, suitable for 24 Hr Continuous Operation, Complete in All respect. 720-1080systemlumens,>120Lm/W, PF>0.95,THD<10%at full load, CRI >80, >300Vover voltage protection, 2.5KV internal Surge Protection, with 5 years warrantee 220 Supply and fixing of LED Tube Light with heavy duty Metal Box type Tube Light fitting 1x22 watt suitable for upto 1x 22 watt LED Polycarbonate tube light complete Including tube suitable for both surface & suspended complete in all respect. (2620 systemlumens, >120Lm/W, PF>0.95, THD<10%, CRI>80, sheet thickness min 0.8mm,Tube with aluminium heat sink, >300 Vover voltage protection, 2.5KV internal Surge Protection, with 5 year warrantee.) 221 Supply & fixing of water tight oblong 10 watt LED Bulk head luminaire having pressure die cast housing with driver set confirming to IP65 and above protection, IK08, Highpurity/ transmisivity UV Stabilized Non yellow ishdiffuser/ for uniform light distribution, detachable driver set, open and short circuit protection, suitable for 24Hr Continuous Operation, Completein All respect. 1200 system lumens, >120Lm /W,PF>0.95, CRI>70,>300V over voltage protection, 4KV internal Surge Protection, metal housing with 5 years warrantee 222 Supply of Heavy Duty Exhaust Fan 300 mm. sweep 900 RPM Single phase complete in all respect. Havells or Eq. 223 Supply of Metallic body fresh air fan 300 mm. sweep complete in all respect. Havells or Eq. 224 Supply and fixing of 7 Watt LED Bulb Output 630 Lm, Color Temp 300 k 0.04 Amp. Havells or Eq. 225 Supply and fixing of 63 Amp. FP MCB (10 KA) 240 V/415 V, 50 Hz Legrand or Eq. 226 Supply & Fixing of Metal Enclosure for Independent Mounting of MCB RCCB, RCBO and DPX3 MCCBs (DP Enclosure & Four Pole Enclosure), Legrand or Eq. 227 Supply of Decorative wall Light fixtures made of polycarbonate suitable for 9 watt LED bulb B22 base LED Lamp complete in all respect. Havells or Eq.