| Sl. No. | Item Description |
| 1 | Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc complete all as specified and directed. |
| 2 | Dismantling Floor, Hearth or Wall Tiling including Cement Mortar Bedding (but not backing), and removing rubbish off the Premises, complete all as specified and as directed. |
| 3 | M&L Non - skid Ceramic colouredtiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed with epoxy filler to match over 15mm thick screed bed in cement mortar (1:6)complete all as specified and as directed. |
| 4 | Taking down Cement Plaster of any description on Brick Walls, Concrete Surfaces including racking out joints, hacking for key, scrubbing down with Water, remove dust, debries/ rubbish, etc., complete all as specified and as directed. |
| 5 | S&F Coloured Glazed ceramic tiles 600 x 300 mm x7 to 8 mm thick, in skirting /dado etc set and jointed in neat cement slurry and pointed with epoxy filler to matchover 10mm screeding in Cement mortar 1:3 complete all as specified and as directed. |
| 6 | Demolition of Cement Concrete of any description in any position not otherwise specifically provided for etc complete all as specified and directed by Engineer-in-Charge. |
| 7 | M&LPCC (1:4:8) Type D-2 using 40mm graded stone aggregate as in foundation/mass concrete complete all as specified and as directed. |
| 8 | M&L for 75mm thick PCC, type C-2, (1:3:6, using 40 mm graded stone aggregates) as in plinth protection and finishing the cement concrete surfaces even and smooth with using extra cement complete all as specified and as directed. |
| 9 | M&L for PCC (1:2:4) type B1 using 20mm graded stone aggregate as in levelling course of floor to receive tiles/wooden flooring to level existing floor to make the surface smooth complete all as specified and directed by Engineer in Charge. |
| 10 | Taking down chowkats or frames exc 1.5sqm and not exc 4.0 sqm each with shutters (without taking off shutters from the frame) including dismantling of PCC bed blocks for hold fasts complete all as specified and directed by Engineer in Charge. |
| 11 | Taking down Chowkat or Frame with shutters (without taking off Shutter from the Frame) n exc. 1.50 Sqmincluding dismantling of PCC bed blocks for hold fasts complete all as specified and directed by Engineer in Charge. |
| 12 | Demolition of brick or stone boulder masonry walling, etc. in any position built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed. |
| 13 | M&L Brick Work with Sub-Class ‘B’ Bricks (with Old Size Bricks), Straight or Curved on Plan exc. 6.0 Metre mean Radius, built in Cement Mortar 1:6, complete all as specified and as directed. |
| 14 | Labour only Brick Work using old bricks obtained from demolition, Straight or Curved on Plan exc. 6.0 Metre mean Radius, built in Cement Mortar 1:6, complete all as specified and as directed. |
| 15 | M&L Brick Work with Sub-Class ‘B’ Bricks Half-Brick thick, Old Size, built in Cement Mortar 1:4, Straight or Curved on Plan to any Radius, complete all as specified and as directed. |
| 16 | M&L Rendering15mm thick in Cement Mortar 1:4 on Brick Walls or on Concrete Surfaces, finishing plastered surfaces Even and fair without using Extra Cement complete all as specified and as directed. |
| 17 | M&L Rendering (Internally) 10mm thick in Cement Mortar 1:6 on Brick Walls or on Concrete Surfaces, finishing plastered surfaces Even and Smooth without using Extra Cement complete all as specified and as directed. |
| 18 | S&FPowder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom andsideswithrequired EPDM rubber/ neoprene gasketetc.Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings complete all as specified and as directed. |
| 19 | S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings complete all as specified and as directed. |
| 20 | S&F 5.0 mm thick heat absorbing/tinted/ frosted glass of any size with aluminium beadingcomplete all as specified and directed. |
| 21 | S&F 4.0 mm thick heat absorbing/tinted/ frosted glass of any size with aluminium beadingcomplete all as specified and directed. |
| 22 | S&F Figured Glass 4.0mm thick, Pin Head / frosted type and glazing with Wooden Beads or Oil Putty in Square or Rectangular, not exc. 0.50 Sqm, complete all as specified and as directed. |
| 23 | S&F Stainless Steel Wire Cloth 0.36mm nominal dia of Wire and average width of aperture 1.40mm and fixed with Stainless Steel Wire Staplescomplete all as specified and as directed.NOTE: Cost of Second Class Hardwood Bead-ing shall deemed to be included against Glazed and Skeleton Shutter. |
| 24 | M&L Preparing new plastered surfaces of Walls andapplying Two Coats of Plastic Emulsion Paint over 10 cm width or girth over a coat of primerandapplied over 1mm thick BIRLA/JK water proof wall care putty including rubbing with emmery paper to make wall surface smooth and even complete all as specified and directed. . |
| 25 | M&L Complete removal of existing Treatment of old decorated Surfaces of Walls andapplying Two Coats of Plastic Emulsion Paint over 10 cm width or girth over a coat of primerandapplied over 1mm thick BIRLA/JK water proof wall care putty including rubbing with emmery paper to make wall surface smooth and even complete all as specified and directed. . |
| 26 | M&L Preparing new plastered surfaces of Wallsand appplying two coats of weather coat (Apex) over two primer coats of damp shield applied by approved applicator as per manufacturer instruction complete all as specified and directed. |
| 27 | M&L Complete removal of existing treatment of old decorated Surfaces of Wallsand appplying two coats of weather coat (Apex) over two primer coats of damp shield including properly fillings the cracks with putty,applied by approved applicator as per manufacturer instruction complete all as specified and directed. |
| 28 | S&F Solid PVCmoulded door frame of size 50mm x 47mm made out of 5mm Prelaminated PVC sheet reinforced with M.S. tube, completeall as specified and directed. |
| 29 | S& F Factory made PVC solid moulded Door Shutter, 30 mm thick with board core (styles), with 2,4 or 6 raised panel design with 2mm thick moulded prelam PVC sheet on the front face & 2mm prelam PVC sheet on back face, supplying and fixing in frame at site completeall as specified and directed. |
| 30 | S&F Exposed GI powder coated snap grid frame for false ceiling 600x600mm size of wall angle 25x25x.55 mm size of cross tee and main tee26x24x0.55mmand 32mm x 24mm x 0.55mmwith 2 mm dia double GI wire with end adjuster at one end only suspender including S & F of 4mm thick E Board decorative type in false ceiling including fixing arrangement from steel truss or any type of truss completeall as specified and directed. |
| 31 | M&L for Machine cut kota stone slab flooring 20-25mm thick over 20mm thk cement screed base in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed. |
| 32 | M&L for Machine cut kota stone slab 20-25mm thick in riser of steps, skirting, dado over 10mm thk cement screed base in CM 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed. |
| 33 | S&F 6.0 mm thick selected quality polished edged mirror, pasted over wall finish surfaces with silicon including stainless steel cup head plugs, corner clamps etccomplete all as specified and directed. |
| 34 | S& F 100 mm stainless steel Butt hingeswith with SS Screw complete all as specified and directed. |
| 35 | S&F Stainless steel barrel tower bolts of extruded section 150 mm long and fixed with screws complete all as specified and directed. |
| 36 | S&F stainless steel handles fabricated type, anodised, 150 mm long and fixed with screws complete all as specified and directed. |
| 37 | M&L Framed Work such as Grills, Gratings, etc. with ends of Bars shouldered and/or riveted, or forged into Spikes; Framed Guard Bars; Barred Iron Doors; Ladders; Framed Balusters; Walk Ways; Railings; Framework of Water Tanks and Similar Work, conforming to Fe-290, Gde-E-165, complete all as speci-fied and as directed. |
| 38 | M&L Preparing new Steel or Iron Surfaces of any description,exe 10 Cm width or girth and applying Two Coats of Synthetic Enamel Paint (First quality) over a coat of Red Oxide, Zinc Chrome Primer, complete all as specified and as directed. |
| 39 | S&F Vitreous China Colour Wash down Water Closet Pan (Pedestal Pattern) with \"p\" or \"s\" trap front or back inletincluding fixing Bolts with and (excluding 10 litre capacity low levelFlushing Cistern) including plastic water closet seat with flat botton cover (coloured) fixed with mild steel chromium plated or aluminium hinging device and making good disturbed Surfaces in Cement Mortar 1:3 and fixed including Taking down/out unserviceable WC Pan and connected Items, complete all as specified and as directed. |
| 40 | S&F in repairs Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. |
| 41 | S&F in repair of Towel Ring of stainless steel fixedand including Chromium plated brass screwscomplete all as specified and directed. |
| 42 | S & F in repairs Toilet paper holder of brass chromium plated fixed to walls with chromium plated(CP) brass screws complete all as specified and directed. |
| 43 | S&F in repair Auto Closing urinal valve alloy CPwith wall flange (push type) for 15mm bore complete all as specified and directed. |
| 44 | S&F Vitreous China White Urinal, bowl type, complete including providing and fixing plugs, bedding urinal against Wall in Cement Mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; and Union for discharge pipecomplete all as specified and as directed. |
| 45 | S&F White PVC Flushing Cistern 10 Litre capacity, Low Level Valve Less, Syphonic Action type with Inlet, Ball Valve, Float and Handleincluding Cutting and pinning in Ends, making good disturbed Surfaces in Cement Mortar 1:3 and fixed including taking down/out unserviceable Flushing Cistern and connected Items, complete all as specified and as directed. |
| 46 | S&F Vitreous china washhand basin pedestal pattern white,flat back size 550 x 400 mm, excluding taps, waste chain, plug and porcelain stopper but including brackets, cutting for and pinning in ends of bracket or erecting standincluding taking down/out unserviceable Flushing Cistern and connected Items complete all as specified and directed. |
| 47 | S&F in repairsaluminum mortice lock verticle type 75 mm4/6 levers complete all as specified and directed. |
| 48 | S&F In repairs Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty complete all as specified and directed. |
| 49 | S&F in repairs floor door stopperaluminium alloy body overall length 140 mm and tongue , anodised with hard drwan steel springcomplete all as specified and directed. |
| 50 | Supply and fix, 32/40 mm dia PTMT 610 mm long waste pipe suitable for WHB as in repair complete all as specified and directed. |
| 51 | S&F in repairsstainless steel grating round/ Square cockroach proof with or without hole100/75mm diaas in repair, |
| 52 | S&F in repairs Soap dish, any type, fixed to plugs with chromium plated brass screws complete all as specified and directed. |
| 53 | S&F, 110mm bore PVC (SWR) pipe single socketed with rubber ring joints fixed to walls or laid in trenches or floor complete all as specified and directed. |
| 54 | S&F, 75mm bore PVC (SWR) pipe single socketed with rubber ring joints fixed to walls or laid in trenches or floor complete all as specified and directed. |
| 55 | S&F PVC (SWR) Bend 100mm bore (dia), any type, equal or unequal with Access Door, etc. and Jointing with Solvent Cement, complete all as specified and as directed. |
| 56 | S&F PVC (SWR) Bend 75mm bore (dia), any type, equal or unequal with Access Door, etc. and Jointing with Solvent Cement, complete all as specified and as directed. |
| 57 | S&F PVC (SWR) Junction 75mm bore (dia), Single (Single T) equal or unequal with access door and Jointing with Solvent Cement, complete all as specified and as directed. |
| 58 | S&F PVC (SWR) Junction 110 mm bore (dia), Single (Single T) equal or unequal with access door and Jointing with Solvent Cement, complete all as specified and as directed. |
| 59 | S&F in repairs stainless steel curtain rod of 20/25 mm bore incl brackets and end knobs for door and window complete all as specified and directed. |
| 60 | S&FGlass shelf assembly consisting of 5.5 mm thick sheet glass self 19-12 cm wide,60 cm long with chromium plated brackets guard andrailing fixed in position with necessary fixing arrangement as in repair complete all as specified and directed. |
| 61 | M&L, as in repair for 75 mm dia of outlet PVC(SWR)floor trap, plain with granting including jointing with solvent cement complete all as specified and directed. |
| 62 | S&F Waste coupling CP 32/40 mm dia for glazed ware basins/ Sink etc with fly nuts flanged including 610 mm long waste pipe etc complete all as specified and directed. |
| 63 | S&F in repairs 15mm dia stop valve fancy type chromium platedscrewed both ends for iron pipe or for unions and fixed complete all as specified and directed |
| 64 | S&FPillar taps fancy type15mm bore of PTMT any colour screwed for iron pipe & fixed. (min weight 15mm-120gms) as in repaircomplete all as specified and directed. |
| 65 | S&F in repair 15mm bore two way bib cock cast copper alloy CPFancy type ,withwall flange screwed down for iron pipe or union , complete all as specified and directed. |
| 66 | M&L P.C.C (1:3:6) type C2 using 40 mm graded stone aggregate for bed to drain pipes including packing under and hunching against side of pipes after they are laid down and tested complete for 150 mm bore pipe complete all as specified and as directed. |
| 67 | M&L Salt-Glazed Stoneware Drain Pipes of Internal dia 150mm Grade ‘A’, laid in concrete bed at trenches, jointed in Cement Mortar 1:1 and tested, complete all as specified and as directed.NOTE : Earthwork shall be Measured and Paid separately under relevant Item(s). |
| 68 | Excavation in trenches not exc. 1.5 Metre wide and not exc. 1.50 Metre in depth for foundation etc. or for shafts, wells, cess pits, manholes, pier holes etc. not exc. 10 Sqm on plan and not exc. 1.50 Metre in depth and getting out as in Soft/Loose Soil, complete all as specified and as directed. |
| 69 | Returning, filling in, including spreading levelling watering and well ramming in layers n,exc 25 cm thick in soft /loose soil for sewage pipe line /manhole and cleaning the site complete all as specified and as directed. |
| 70 | Removing excavated materials n.exc 50 mtr and depositing where directed at level n.exc 1.5 mtr above the starting point complete all as specified and directed. |
| 71 | S&F Unplasticised PVC pipes 15 mm bore of pressure rating 10 kgf/cm2 fixedto walls, ceilings or in floors etc with necessary fixing arrangements includingtaking down old unserviceable pipe any type and size complete all as specified and directed. |
| 72 | S&F Unplasticised PVC pipes 20 mm bore of pressure rating 10 kgf/cm2 fixedto walls, ceilings or in floors etc with necessary fixing arrangements includingtaking down old unserviceable pipe any type and size complete all as specified and directed. |
| 73 | Demolition of old damaged existing water proofing treatment on RCC roof of any description and specification andcleaning the surface thoroughly complete all as specified and directed. |
| 74 | M&L 15mm thick in cement mortar (1:4) on existing roof surface totrue level after applying cement slurry @3Kg/Sqm complete all as specified and directed. |
| 75 | M&L Water Proofing Treatment on existing cleaned RCC Roof with the following Specifications and Manufacturer\"s instructions, complete all as specified and as directed :-(a) Preparing and cleaning of fully drysurface as per IS:3067-1966.(b) Applying Bitumen Primer conforming to IS-3384-1986 over the Cleaned Plastered Surface @ 0.50 Litre per Sqm.(salitex primer of STP)(c)Applying coat of hot applied bitumen 85/25 @ 1.20 Kg/Sq m of surfaces(d) Applying a layer of APP based Polymeric Membrance; 3.0mm thick (minimum) weighing 3.60 Kilogram per Square Metre (reinforced) with Polyster Non Woven Fabric weighing not less than 160 Grams per Square Metre by Torch application. The overlaps shall be minimum 100mm on the Transverse direction and 75mm on Longitudinal direction.(d) Applying one coat of Aluminium Paint @ 0.10 Litre per Sqm over APP based Polymeric Membrane. |
| 76 | M&L for Vitrified parkingtiles of any colour/patern 40cm x 40 cm x 7 to 10 mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigments in floors and over 15 mm thick screed bed in CM 1:4 for laying floor finishes complete all as specified and as directed |
| 77 | M&L RCC (Nominal Mix) 1:1.5:3 type B-1 (Using 20mm graded stone aggreagate) as in Beams, cantilevers, bressummers, lintels over 1.5m spancomplete all as specified and as directed.NOTE : Formwork and Reinforcement shall be Measured and Paid for separately under relevant Items. |
| 78 | M&L Formwork to Sides and Soffits of Floor or Roof Beams, Beam Haunchings, Girders, Bres-Summers, Lintels, Cantilevers, Shelves including supports, overhangs, etc. also splays between floors and beams, etc., flat, rough finished surfaces of concrete, complete all as specified and as directed. |
| 79 | M&L TMT Bars 10 mm dia and over, cut to length, bent to shape required including crank-ing, bending and bindingwith and including Mild Steel Wire (annealed) not less than 0.90 mm, complete all as specified and as directed. |
| 80 | M&L TMT Bars 8 mm dia , cut to length, bent to shape required including crank-ing, bending and bindingwith and including Mild Steel Wire (annealed) not less than 0.90 mm, complete all as specified and as directed. |
| 81 | Surface excvation n.exe 30 CM deep and avg 15CM deep and getting out in soft/loose soil complete all as specified and as directed. |
| 82 | M&L Hardcore of gauge not exc. 63 mm, broken stone aggregate deposited, spread andlevelled in layers n exc. 15 Cm thick, watered and rammed to a True Surface, complete all as specified and as directed. |
| 83 | M&L Sand Filling under floors or in foundations including watering and consolidation complete all as specified and as directed. |
| 84 | M&L 20mm thick Granite stone (of any type & any colour/ shade) work (table rubbed and polished) in cooking platforms/ stepsand like fixed in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match over with shade of granite complete all as specified and as directed. |
| 85 | M&L 20mm thick Granite (of any type & any colour/ shade) work (table rubbed and polished) forin skirting/border/ dado with 12 mm thick in cement mortar (1:3) and pointing with white cement(1:2) using marble dust with admixture of pigment to match with shed of granitecomplete all as specified and as directed. |
| 86 | M&L Reinforced Cement Concrete Type B1 (1:1.5:3) (20mm graded crushed stone aggregate) asin Foundations including Rafts, Footings, Foundation Beams; Plinth Beams; bases for Columns, etc.; Basement Slabs, Under-reamed Piles and Mass Concrete, complete all as specified and as directed.NOTE : Formwork and Reinforcement shall be Measured and Paid for separately under relevant Items. |
| 87 | M&L Reinforced Cement Concrete Type B1 (1:1.5:3) (20mm graded crushed stone aggregate)in Columns, Pillars, Piers, Posts and Struts, etc. complete all as specified and as directed.NOTE : Formwork and Reinforcement shall be Measured and Paid for separately under relevant Items. |
| 88 | M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for flat & rough finished surfaces of concrete complete all as specified and as directed. |
| 89 | M&L for Formwork to sides of pillars, posts, struts, piers, columns and stanchionsUse for rough finished surfaces of concrete complete all as specified and as directed. |
| 90 | M&L for 100 mm thick PCC 1:3:6 type C2 using (40 mm graded aggregate) as in sub baseof floor etc. complete all as specifed and as directed. |
| 91 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.including cutting chases of exsisting wall for wall taking out concealed conduit ec. and making good disturbed surfaces of walls, floors, etc as per existing specification after providing point wiring under respective items here-in-below complete all as specified and as directed. |
| 92 | M&L Concealed point wiring for one Light/ Fan/ Bell point complete with 1.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LSH cable 1100 volts grade (ISI marked) with proper colour coad drawn through and including non-metallic rigid PVC medium grade conduit not less that 20 mm dia and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LSH (ISI marked) as earth continuity conductor connected to common earth dolly, with and including modular metal flush box and Modular white Cover Plate with Frame for fixing modular switches, sockets fan regulators etc duly earthed.Connections of cable with MCBs or bus bar shall be sone through proper size of copper/brass thimbles complete all as specified and as directed.Note (i) Red coloured cable shall be used for live connection,black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board.(ii) Cutting Chases pinning shall deemed to be included in the quoted rate of Sch A. (iii) The cost of Blanking plate if required shall deemed to be included in the unit price. |
| 93 | All as per item No. 93here-in- before but for 3 pin 5 Amps switch socket combination on independent board with 1.5 sq mm copper cable complete all as specified and as directed. |
| 94 | All as per item No. 93here-in- before but for 3 pin 15 Amps switch socket combination on independent board with 2.5 sq mm copper cable complete all as specified and as directed. |
| 95 | All as per item No. 93 here - in - before but for 5 Amps socket point on the same board controlled by one switch. |
| 96 | S&F Modular switch flush type, 6 Amp, one way ,1 module complete all as specified and as directed. |
| 97 | S&F Modular socket outlet, 3 pin, 6 Amp, flush type 2 module complete all as specified and as directed. |
| 98 | S&F Modularswitch, 16 Amp flush type 1 module complete all as specified and as directed. |
| 99 | S&F Modularsocket outlet, 3 pin, 6/16 Amp flush type 2 module complete all as specified and as directed. |
| 100 | S&F ModularFan Regulator stepped type 2 module ,120Wcomplete all as specified and as directed. |
| 101 | S&FCeiling rose, surface bakelite, 65 x 50 mm,three terminals complete all as specified and directed. |
| 102 | Supply and fix LED tube light fitting of 18 W with tube (4 Ft) 240 V Wall mounted LED batten polycarbonate housing and integrated electronic driver with high efficient LEDs 18 Watt with accessories suitable for operation on AC single phase 220/230 volt 50 Hz supply complete with all accessories internally pre-wired and including connection complete all as specified and directed. |
| 103 | Supply and fix LED tube light fitting of 9 W with tube (2 Ft) 240 V Wall mounted LED batten polycarbonate housing and integrated electronic driver with high efficient LEDs 18 Watt with accessories suitable for operation on AC single phase 220/230 volt 50 Hz supply complete with all accessories internally pre-wired and including connection complete all as specified and directed. |
| 104 | Supply and fix for Recessed mounting high lumen output LED light fittings of size 2 ft X 2 ft for metalic false ceiling type armstrong/US gypsum or similar ceiling mounting system with concealed or exposed \"T\" section including 36 watt LED CDL light, complete all as specified and directed. |
| 105 | Supply and fixingwall mounting hi-flow and heavy duty fan with all accessories of Size 400 mm sweep, 230 volt Acwith connection from existing ceiling rosecomplete all as specified and as directed.Make :- Crompton/Polar/Havells/Bajaj. |
| 106 | S&F Metal clad socket out let with MCB single pole and nutral 20-32 Amp, 240 V including sheet metal enclosure complete fixed on board including complete electrical connection by proper size of copper lugs complete all as specified and as directed. |
| 107 | Taking down old burnt/unserviceable sub main wiring with aluminum/copper conductor PVC insulated cable of any size drawn through PVC casing caping/ PVC Conduit pipeincluding GI wire accessories etc. and making good disturbed surfaces of walls, floors, etccomplete all as specified and directed. |
| 108 | M&L Sub main wiring with 2 runs of single core FRLSH type PVC insulated unsheathed stranded copper conductor of size 4.0 Sqmm and one run of PVC insulated unsheathed multistrand copper conductor FRLSH type of size 4.0 Sqmm as earth lead drawninto rigid non metalic PVC conduit of size 25 mm dia with all fittings including making good the disturbed surface by Putty and matching the colour with existing wall surfacewherever required (as per the existing condition)complete all as specified and as directed.Note:- Two runsof 4 Sqmm conductor as main wireand one run of 4 Sqmm conductor as earth wire with one run of PVC conduit shall be measured as one unit. |
| 109 | Supply and fixing sheet metal enclosure for MCB, DBs, phosphatised, Powder coated , Tripplepole and neutral (TPN) 415 Volt , double door, suitable for 4 way with din rail earth and neutral bar complete all as specified and as directed. |
| 110 | S & F MCB \"C\" series Triple pole and neutral 63-100 Amps, breaking capacity 10KA complete all as specified and directed. |
| 111 | S & F MCB \"C\" series Single pole and neutral 40-63 Amps, breaking capacity 10KA,complete all as specified and directed. |
| 112 | S & F MCB \"C\" series single pole 6 to 32 Amps, breaking capacity 10KA,complete all as specified and directed. |
| 113 | M&L for earthing complete with galvanised steel earth plate electrode 60 x 60 cm x 6mm thick buried directly in ground ( earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less thab 1.5 Meter below normal ground level connected to GI wire 4 mm dia by means of bolts, nuts , check nuts and washers of GI and GI tubing 20 mm bore light grade for earth lead protection up to main earth test point and including concrete pit in PCC (1:3:6) type C1 pre cast RCC (1:2:4) type B1 cover slab 54 x 54 x 5 cm with one handle for lifting made out of 8 mm dia MS bar, wire mesh, 20 mm bore GI tubing (LG) for watering, charcoal or coal and salt in alternate layers including excavation earth work. electrical plate No. 3 of SSR part - I complete all as specified and directed. |
| 114 | Supply, laying, jointing and testing LT cable in trenches or on poles / walls, XLPE Insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm, 3.5 core complete all as specified and directed. Note:1. Excavation and earth work will be measured and paid seperately. |
| 115 | Supply, laying, jointing and testing LT cable in trenches or on poles / walls, XLPE Insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm, 4.0 core complete all as specified and directed. Note:1. Excavation and earth work will be measured and paid seperately. |
| 116 | M&L for 80 mm dia GI tubing light grade with all necessary fittings laid in trenches, fixed to walls/ poles/ under road/ floor etc for cable protection, complete all as specified and directed. |
| 117 | Supply and laying dry coarse sand as in cushioning of under ground electric cable in trenches, laid to a uniform thickness of 23 Cm (15 Cm under the cable & 8 Cm over the cable) and gently punned down to 18 Cm thickness complete all as specified and as directed by the Engr-in-Charge.Note:- Thickness after punning down shall be measured for payment. |
| 118 | Supply and laying in trenches Bricks, sub class \"B\" over burnt (kiln burnt) old size bricks, laid flat dry with width of the bricks laid to the axis of the cable for protection of cable complete all as specified and as directed by the Engr-in-Charge. |
| 119 | Supply, install, testing & commissioning of hi wall, split-type Air Conditioner Unit of capacity 2.0 TR based on Inverter Technology comprising of indivisual indoor & outdoor units complete with cordless remote control unit & with in-builtair ionizer & plasma filter for better indoor air quality with minimum 5 star rated incl electric connection complete all as specified and directed. Make:-LG/Samsung/Hitachi/Voltas/Blue star/Haier/Carrier/GodrejNOTE :(i) The Air Conditioner shall be initial filled / charged with refrigerant of specified quantity & the refrigerant to be used shall of Non-CFC type & as per the latest technology.(ii) The cost of additional refrigerant pipes required (if any) is deemed to be included in the unit quoted rates.(iii) Suitable piping of adequate length & size 5/8\" for drainage of condensate water from indoor unit shall be provided & the cost of the same is deemed to be included in the unit quoted rates.(iv) Anything missed out in the technical specifications but technically required for efficient working of the AC is deemed to be included in the unit quoted rates. |
| 120 | Supply and fix voltage stabilizer for automatic operation ,single phase naturally air cooled indoor type & designed for input variation between 130 Vto 300 V with out putvoltage stabilized at 230 volt with accuracy of( +-) 2.5 % and of capacity 4 KVAcomplete all as specified and as directed.Note 1:-The contract sum shall be arrived at after deducting amount of schedule of credit from the total quoted amount. Note 2-Contractor\"s supervisor and main worker would wear shirt/T-shirt of colour sky blue/brown/yellow preferable embossed with contractor\"s firm name while carrying out any activities in defence area for better check of security purpose.Note 3:-The tenderer (all eligible contractors) shall ascertain the taxes & levies as on date. The subject tender caters all the taxes & levies as on date including the latest notification of GST issued as on date ( issued by Central Board of Indirect Taxes and Customs) |