Tender For Special Repair To Building No T 11 Of Shopping Complex And Special Repair To Building No T 16 Of Shopping Complex At Mil Station Gaya.; 1 Dismantling of asbestos cement (corrugated or semi corrugated) sheets as in roof coverings complete all as specified and directed. 2 S & F Prepainted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering, fixed with self tapping screws as specified and directed. 3 S & F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour as in roof covering/Valley/Gutter/Ridges, fixed with self tapping screws complete. 4 Dismentling Timber scantling 40 sqcm over in sectionin any descriptioncomplete all as spd. 5 S&F roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming Fe 410 -W (GdeE- 250) qualityA complete all as specifed. 6 S&F Mild steel plates (plain or chequered) channels, sqares cut or notched (ordinary and counter-sunk) forming holes without any attachment. Fe 410 W Gde E -250 quality - B complete. 7 Fabrication & Erection only of existing Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings including necessary cutting and welding of existing trusses/rafters/pulins after removing the rust and refixed as in position all as specified and directed. 8 Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quions, arches, pillars, etc, dressed stone work and precast concrete article 9 Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc 10 M & L for Brick work with subclass B bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete. 11 M & L for Brick work with subclass B bricks, (Except Bricks)straight or curved on plan exc 6m mean radius built in CM 1:6 complete. 12 M & L for brick work with sub class B bricks, in half brick thick wall, straight or curved on plan exc 6m mean radius built in CM 1:4 complete. 13 M & L for 10 mm thick rendering in CM 1:6 on brick work or concrete surfaces of wall and finished surfaces fair and even without using extra cement complete. 14 M & L for 15 mm thick rendering in CM 1:4 over fair faces of brick work or concrete surfaces of wall and finished surfaces fair and even without using extra cement with WPC. 15 Supply Only integral water proofing compound 16 M & L for two coats of cement based paint over a coat of primer incl preparation of newly plastered wall surfaces. 17 M & L for applying a thin layer of 1.00 mm thick Birla white putty/JK white wall care putty on new/old wall surfaces including removal of existing treatment and making the surface uniform and smooth complete all as specified and directed. 18 M & L for preparation of old plasteredsurfaces and applying one coat of acrylic distemper on walls complete all as specified and as directed. 19 M & L for preparation of new plasteredsurfaces and applying two coat of acrylic distemper on walls complete all as specified and as directed. 20 Dismanteling ceiling and wall boards of any type or any thickness inclluding cover fillets compleate all as specified and directed 21 M & L for anodised aluminium snap grid frame work for false ceiling all as specified and as directed. 22 S&F 4mm thick HSPC non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws as in ceiling. 23 Dismantling floor, hearth or wall tilling including cement mortar bedding , removing serviceable tiles to store and rubbish off the premises. 24 M & L for Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed in CM 1:4 complete. 25 M & L for coloured glazed ceramic tiles in vertical surface 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match incl 10mm thick rendering in cement mortar 1:4as backing for tiles complete all as specified and as directed. 26 M & L for non skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exc 0.06 Sqm but not exc. 0.16 Sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed or bedding layer with CM 1:4 complete. 27 M&L for 20mm thick granite slab, machine cut, well polished, bedded in 15mm thick in CM 1:4 as in cooking plaforms & like and jointed with grey cement slurry and pointed with white cement(1:2) using marble dust with admixtures of pigments to match the shade of granite stone including cutting, polishing and rounding of edges etc. complete all as specified and directed. 28 Taking down chowkhat or frame exc 1.5 sqm but not exc 4.00 sqm (without taking off shutter) and removing to store/taking in safe custody for refixing the same complete all as specified and directed. 29 S&Faluminum frame for doors, windows, ventilators with one or more rebates including jointing cleat for fixing etc. complete all as specified and directed. 30 S&Fany colour, aluminum door shutters , aluminium section weighing 0.55 Kg/ Sqm including necessary jointing cleats, glazing clips, ruber neoprene packing, handles & tower bolts 02 Nos in each door, hinges, anodised aluminium snap beading, screws etc. complete all as specified and directed. 31 S&F10mm thick Toughned glass as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes required complete all as specified and directed. 32 S & F in repairs Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty complete all as specified. 33 S & F 100 mm long mortice lock with four levers(vertical type), brass body complete all as specified and directed. 34 M&L 18/19mm thick prelaminatedparticle board exterior grade prelaminatedone side with decorativechoice lamination and other side balancingwhite lamination, fixed with screws to timberframed work including fixing arrangement complete all as specified 35 S&Fcontinuous piano hinges mild steel bright finish of flap width 30mm 36 S&F 40m dia cup board knobs fixed with nut , screw and washer of brass polished 37 M&L Hasp and staplesafety type aluminum anodised75mm size with mild steel hinge pin includingbolt to hinge plate and fixedwith screws complete all as specified 38 Demolition of reinforced cement concrete in ground floors and pavings n exc 15 cm thickness below or above GL 39 M & L for Reinforced cement concrete (nominal mix) Type B1 1:2:4 (20 mm graded stone aggregate) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like. 40 M & L for use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) rough finished flat surface of concrete complete all as specified and directed. 41 M&L for Mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete. 42 M & L for applying two coat of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surfaces 43 M & L for applying a coat of synthetic enamel paint including preparation of old painted steel surfaces 44 S&F as in repair PVC connections 15mm size with PTMT nuts of length 600 mm all as specified and as directed. 45 S&F in repairs 10 ltr capacity PVC low level flushing cistern white, ISI marked make as specified with inlet, float valve and handle including breacket with 32mm dia PVC pipe 600mm long complete all as specified and directed 46 S & F in repairs vitreous China wash basin, white, flat back, size 550 x 400 mm including a pair of bracket, 32mm dia CP waste and 15mm bore CP pillar tap screwed to iron pipe complete all as specified and directed. 47 S & F in repair Vitreous China wash down water closet pan (pedestal pattern), white including fixing bolts, but excuding flushing cistern and flush pipe complete all as specified and directed. 48 S & F as in repair of white soft closing seat cover for pedestal pattern water closet including fixing bolts complete. 49 S&F brass chromium plated health faucet 15 mm with flexible tube (1.5 m long) of stainless steel provided rubber hose and wall hook etccomplete as in repair all as specified. 50 S & F in repair 6mm thick looking mirror of 1st quality glass, mounted on 6mm thick commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete.(Saint Gobain/ModiFloat) 51 S&F in repair 15 mm dia bore bib taps, brass chromium plated fancy type with crutch alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed. 52 S&F in repair15mm dia bore pillar tap cast copper alloy, wih capstan heads, chromium plated , screwed down high pressure with or without lettered Hot or cold with long screwed shank and flynust, screwed for iron pipe and fixed complete all as specified and as directed 53 S&F in repair brass chromium plated tubler towel rail 20mm dia D type, 60cm long between flanges complete all as specified and as dirceted 54 S&F in repair 15 mm dia stop/angle valves, cast copper alloy, CP fancy type, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe. 55 S & F in repairs CPVC pipes 20 mm outer dia SDR 11 & Plain CPVC SDR 11includig all fittings on walls/ceiling or laying in floors including necessary cutting/chasing of walls and floors complete. 56 S&F in repair kitchen sink with drainage board made out of 1mm thick stainless steel with plugs washers and wastes including bedding in cement mortar to dwarf wall or including fixing cantilever bracket and connecting union to pipe over all size 915mmx460mm & bowl size 410mm x330mmx160mm complete all as directed by the Engineer-in-Charge 57 S & F of Male Brass Threaded Adaptor (MTA/ MBTA)or Feale Brass Threaded Adaptor (FTA/ FBTA) complete. 58 S&F in replacement 32mm dia PVC waste pipe for WHB complete all as specified and as directed. 59 S& F 1000 Ltr capacity of rotational moulded polyethylen water storage tank (Cylindrical vertical with closed tap) hoisted and fixed in position including S&F 20mm dia GI pipe medium grade washout pipe 450mm long with plug and 20mm dia GI pipe medium grade overflow pipe 600 mm long with fitting and including dismantling of tank complete all as specified and as directed by the Engineer-In- Charge. 60 Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete. 61 S & F Plain, Aluminium sheeting, 0.71mm thk alloy 31000 H4 in ridges, hips, valley gutter, drip and straight flashing (length and girth as fixed), fixed with self tapping screws, revits, nuts bolts as required on site with clamps etc complete. 62 Demolition of cement Concrete(unreinforced)in ground floors and pavings n exc 15 cm thickness (below or above ground level) or as in sunken 63 M & L PCC 1:3:6, type C-2, 50mm thick as in plinth protection, Surface finished fair and smooth without using extra cement. 64 M & L for cement concrete type D-2, 1:4:8 using 40mm graded stone aggregae as in foundations, filling and mass concrete complete. 65 Sand filling under floors for cushioning ofincluding watering and consolidation 66 M & L for machine pressed precast conctete interlocking paver block matt glossy finish any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade with grey cement and no pigment complete all as specified and directed. 67 M & L for Providing, cement concrete type B1, 1:2:4 (using 20 mm graded stone aggregate) in cills, steps; seismic and other similar bands, plinth courses copings including necessary form work all as specified and as directed 68 Taking down copper /aluminium point wiring (light, fan, bell,socketor power) complete including fixture and fittings such as switches, ceiling roses, pendent, regulators, sockets, light fitting etc. Removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition seperately) and making good disturbed surfaces of walls, floors etc complete all as specified and directed at site. 69 Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main Switch including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface complete all as specified and directed. 70 Taking down carefully copper/aluminium sub main wiring of any size fromsurface/ concealed/ existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed. 71 M & L for point wiring using approved colour coding as per IS with multistranded copper conductor 1.5 Sqmm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after chasing in wall/ ceiling etc, heavy duty ISI marked, with GI sunken boxes 1.2 mm thick, 60 mm deep with earth dolly duly, covered with modular white cover plate with inner frame suitable for modular switches, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed for the following :- 72 (a) One light point controlled by one way switch 5 Amps 73 (b) One wall fan point/ exhaust fan point controlled by one, one way switch 5 Amps 74 (c) One 3 pin 5 Amps switch socket outlet point controlled by one switch on the same board. 75 (d) One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board. 76 Description all as per item No 4 here-in-before but using 2.5 Sqmm single core copper conductor cable of multistranded FRLSH, PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket combination point including necessary running of2.5 sq mm copper conductor FRLSH, PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly. 77 Description all as per item No. 4 here in before butusing 4.0 sq mm single core copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of4.0 sq mm PVC insulated copper conductor FRLS cable as earth continuity conductor along with wiring and connecting to the common eath dolly. (for AC Point) 78 S & F modular switch piano flushtype, single pole, one way and 5/6 Amp single module complete. 79 S & F modular switch piano flush type, single pole, one way and 15/16 Amp single module complete. 80 S & F modular socket outlet multipurpose with provision of 3 pin, 5/6 Amp and 2 pin, 5/6 Amp, 2 module piano flush type complete. 81 S & F modular socket outlet multipurpose with provision of 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, 2 module piano flush type complete. 82 S & F ceiling rose, surface bakelite with 3 terminals, ISImarked for batten fitting complete all as specified. 83 M & L for sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable sizeincluding concealed in wall etcone run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable, one run of 6 sqmm cable and one run of PVC conduit will be measured as one unit 84 All as per item Srl No. 12 above but cable for two runs of 4 Sqmm and one run of 2.5 Sqmm 85 S & F for sheet metal enclosure MCB DB TPN 4 way vertical type with 200 Amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. 86 S & F for sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. 87 S & F for MCB tripple pole and neutral rated capacity 63 Amps, 415 Volts breaking capacity 10 KA, C curve complete all as specified and as directed. 88 S & F for MCB Single pole and neutral rated capacity 40 Amps, 240 Volts breaking capacity 10 KA, C curve complete all as specified and as directed. 89 S & F for MCB Single pole rated capacity 5 to 32 Amps, 240 Volts breaking capacity 10 KA, C curve complete all as specified and as directed. 90 S & F sheet metal enclosure for single pole and neutral with two pin and earth plug top and socket complete with one single pole MCB 20 Amps complete all as specified and directed. 91 S & F Wall mounted fans 230 V 300mm sweep five star rated including connections from ceiling rose to fan terminal complete all as specified and directed. 92 S & F for energy efficient exhaust fan of 250 mm sweep made of plastic body Ventil Air -DS type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan forconnection and making suitable size ofhole to existing brick wall for fan basecompelte all as specifiedand directed.(Note : Cost of suitable opening wall for fixing exhaust fan is deemed to be includedin overall rate quoted). 93 S & F for wall mounted LED tube light fitting 20 watts batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouput box type fitting, 230 volts and intregrated electronic driverconnector block etc with warranty option of 5 years from date of installation complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and directed. 94 S&F in replacement of LED panel light fitting 36 watt LED (2x2 ft), LED panel fitting, including LED in white230 volt energy saving environmental friendly, long life, corrosion resistant, impact proof, surface mounting IP-65 luminaire with PC housing in opal finish suitable for wet location with brighness LEDs with all accessories internally prewired and including connected with twin core twisted flexible wire copper conductor cable with suitable size complete all as specified and directed. 95 M & L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level, connecting to GI earth wire 4mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 15 mm dia medium grade protection pipe for earth lead complete with charcoal and common salt including watering arrangement with galvanized iron pipe light grade 20 mm dia, PCC Chamber, CI frame and cover, MS funnel with wire mesh all as shown in electrical plate no 3 of SSR part I including excavation and earthwork in any type of soil/strata and testing on completion. Note: GI earth wire 4 mm dia and 15 mm dia protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted. 96 Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 70 Sqmm x 3.5 Core passing through DWC HDPE / in trench including necessary connection with lugs and cable gland etc complete all as specified and directed. 97 M & L for laying of HDPE double wall corrugated pipes in trench for UG cable protection conforming to IS-14930 Part-II with IP-67 having outer dia 50 mm and inner dia of 38 mm including necessary fittings such as couplers, bends etc complete all as specified and directed. 98 Excavation in trenches n.exc 1.5 mtr wide and 1.5 mtr in depth in hard/dense soil for taking up/ laying of cable and getting out complete all as specified and directed. 99 Returning, filling in excavated soil including spreading, leveling, watering and well ramming in layers n.exc 25 cm complete all as specified and directed. 100 Removing surplus soil to a distance n.exc 50 mtr and making good the disturbed surfaces complete all as specified and directed. 101 Supply and laying river bed fine sand in trenches/ ducts 15 cm under cable and 8 cm above the cable for cushioning / protection to cable including spreading, levelling and get thick 18cm after hand punning complete all as specified and directed at site. 102 Supply and laying for brick of common burnt clay, sub class B old size laid flat and dry on cables as in cable protection in trenches over cables perpendicular to direction of cables abutting each other complete all as specified and directed. 103 Dismantling timber scantling, framed /un framed workof 40 sq. cm and over in section in any position complete as directed. 104 Dismantling structural steel work in cluding doors, gates but excluding framed truss etc in any position complete as directed. 105 S and F for Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts 106 S and F of framed work as in doors orgates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete. 107 M & L for applying two coat of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surfaces 108 M&L renderig 15mm thick in cementmortar 1:6 overfair faces of of brick or concrete surface of wall rendering is to be finished even and smooth without using extra cement 109 M & L preparing surfaces of wall by complete removal of existing treament andapplying two coat of oil emulsion distemper on wallscomplete all as specified and as directed. 110 M & L for complete removal of existing treament andapplying two coat of cement base paint over a coat of alkali resistant priming paint on external surface complete all as specified and as directed. 111 M & L for applying a thin layer of 1.00 mm thick Birla white putty/JK white wall care putty on new/old wall surfaces includingmaking the surface uniform and smooth complete all as specified and directed. 112 S&F of anodised aluminium snap grid frame work for false celing all as specified and hangers 6mm dia GI adjusting level fixed to roof slabs by means of celling cleats made out of GI flat 40mm X 3mm size 60mm long complet all as specified. 113 M&L for for 4 mm thick high pressure steam cured non asbestos fiber cement designer board of size 600mm x 600mm as in ceiling complete all as specified and directed with and including aluminium anodised snap grid frame 114 Taking down chowkhat or frames with shutters (without taking off shutters from the frame) not exe 1.5 Sqm each etc complete as directed. 115 Taking down chowkhat or frames with shutters (without taking off shutters from the frame) exc 1.50 sqm but not exe 4.0 Sqm each etc complete as directed. 116 S&Fany colour, aluminum window and ventilator shutters, side hung type with sash bars, aluminium section weighing 0.55 Kg/ Sqm including necessary jointing cleats, glazing clips, ruber packing, anodised aluminium snap beading, screws etc. complete all as specified and directed. 117 S& F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard sectionand fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer in-charge 118 S&F Sheet glass 5.5 mm thickness, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane 119 S/F galvanised mild steel wire clothes 0.56 mm nominal dia of wire and average width of aperture1.18 mm completefixed with tinned tacks or galvanised wire staples all as specified and as directed 120 Demolition of cement concrete (unreinforced )in ground floor and paving n,exc 15cm thickness below or above ground level)complete all as specified and as directed 121 S & F Collapsible steel gates, top hung, consisting for channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, complete 122 Dismantling floor, hearth or wall tilling including cement mortar bedding , removing serviceable tiles to store and rubbish off the premises. 123 M&L for vitrified ceramic tiles light shed 10 mm thick (square/ rectangular) polished, area of each tiles notexceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and incl 15mm thick screed bed or bedding layer with CM 1:4complete. 124 All as per ser item No 38 above but in skirting and dado including rendering/screeding including cement mortar1:4 , 10mm thick complete. 125 Taking down carefully ceiling fan of any type from any height and removing the same at site complete all as specified and directed. 126 M & L for point wiring using approved colour coding as per IS with multistranded copper conductor 1.5 Sqmm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after chasing in wall/ ceiling etc, heavy duty ISI marked, with GI sunken boxes 1.2 mm thick, 60 mm deep with earth dolly duly, covered with modular white cover plate with inner frame suitable for modular switches, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed for the following :- 127 S & Fmodular ceiling fan regulator suitable electronic rotary step type 100 Watt 1 module ISI marked. 128 Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.0 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and as directed. 129 Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 35 Sqmm x 3.5 Core passing through DWC HDPE / in trench including necessary connection with lugs and cable gland etc complete all as specified and directed. 130 Supply and fixing and replacement GI pipe, light grade 40 mm bore, ISI Marked for protection to cable along the pole/across road crossing/passing through culvertcomplete all as specified. 131 Supply and laying river bed fine sand in trenches/ ducts 15 cm under cable and 8 cm above the cable for cushioning / protection to cable including spreading, levelling and get thick 18cm after hand punning complete all as specified and directed at site.