Tender For Upgradation work of Tourism Bhawan in Gomti Nagar, District Lucknow - Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil. 2 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. 3 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 4 Providing and laying Cement concrete 1:4:8 (1cement :4 coarse sand :8graded stone ballast 40 mm. nominal size) including supply of all materials, labour and T&P etc. required for proper completion of the work and curing complete, also including cost of formwork in foundation and floors. 5 Providing & laying in position machine batched and machine. Mixed design mix M-25 grade cement concrete for reinforcement cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying Excluding the cost of centering, shuttering , finishing and but excluding reinforcement , including admixtures in recommended proportion as per IS : 9103 to acclerate, retarder for setting of concrete/ improve workability without impairing strength and durability as per direction of Engineer-in-charge. Note :- Cement content considered in this item @ 330 kg/cum. Excess or less cement used as per design mix is payable or recoverable separately.R.C.C. work Upto plinth Lvl. (M-25)All works upto plinth level 6 Providing & laying in position machine batched and machine. Mixed design mix M-25 grade cement concrete for reinforcement cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying excluding the cost of centering, shuttering , finishing and but excluding reinforcement , including admixtures in recommended proportion as per IS : 9103 to acclerate, retarder for setting of concrete/ improve workability without impairing strength and durability as per direction of Engineer-in-charge. Note :- Cement content considered in this item @ 330 kg/cum. Excess or less cement used as per design mix is payable or recoverable separately. R.C.C. work Above plinth Lvl. (M-25)All works above plinth level upto floor V level 7 7 Centering and shuttering including strutting, propping etc. and removal of form for :Foundations, footings, bases of columns, etc. for mass concrete 8 Suspended floors, roofs, landings, balconies and access platform 9 Lintels, beams, plinth beams, girders, bressumers and cantilevers 10 Columns, Pillars, Piers, Abutments, Posts and Struts 11 Stairs, (excluding landings) except spiral-staircases 12 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) FLOOR GR. 13 Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameterholes and plugging with cement mortar 1:2 (1 cement:2 coarse sand) to match the existing floor.With Chlorpyriphos/ Linadane E.C. 20% with 1% concentration. 14 Thermo-Mechanically Treated bars of grade Fe-500D or more work such as in reinforced concreted or reinforced brick work (when not included in overall rates) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage. 15 Providing and fixing SS tower bolts ISI marked anodisedtransparent or dyed to required colour or shade with necessary screws etc. complete : 250x10 mm. 16 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: (Both side laminated)(a) 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. Single leaf. 17 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 18 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) 19 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) 20 Add for plaster groove in plastered surface or moulding to R.C.C. projections 21 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm 22 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) 23 62 mm thick cement concrete flooring with concrete hardener topping,under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarsesand : 4 graded stone aggregate 20mm nominal size) and top layer12mm thick cement hardener consisting of mix 1:2 (1 cement hardenermix : 2 graded stone aggregate, 6mm nominal size) by volume, hardeningcompound mixed @ 2 litre per 50 kg of cement or as per manufacture’sspecifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. 24 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm 25 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 26 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels,bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering,finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (LINTEL) 27 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. 28 Providing and fixing SS sliding door bolts ISI marked anodised transparent or dyed to required colour or shade with nuts and screws etc. complete : 250x16 mm. 29 Providing and fixing SS tower bolts ISI marked anodisedtransparent or dyed to required colour or shade with necessary screws etc. complete : 250x10 mm. 30 Providing and fixing SS handles ISI marked anodisedtransparent or dyed to required colour or shade with necessary screws etc. complete :125 mm. 31 Providing and fixing bright finished brass hanging type floor door stopperwith necessary screws, etc. complete. 32 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: (Both side laminated) (b) Double leaf 33 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 34 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) 35 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) 36 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :5.5 mm thick glass panes 37 Providing and fixing stainless steel (Grade 304) railing made of hallow tubes, chanells, plates etc. including welding grinding buffing, polising and making corvechare (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer in charge.(for payment purpose only weight of stainless steel members shall be considered excluding fixing assessories such as nuts, bolts, fasteners etc. 38 Brick Tile Cladding upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : 39 12 mm thick plaster with cement mortar in consisting of 1:6 cement and approved coarse sand of minimum thickness not be less than 10 mm including supply of all materials, labour T&P etc. required for proper completion of the work. On smooth surface of wall.FLOOR GR. 40 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 41 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre. 42 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge 43 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. 44 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. 45 Supply and fixing of fire extinguisher, ABC Type (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket,along with supply of all materials and labour for proper completion of work.6.0 kg. capacity 46 Providing and fixing soil, waste, vent pipesCentrifugally cast (spun) iron S&S pipe 100mm dia cast (spun) iron S&S pipe 47 Providing and fixing MS holder bat clamps of approved design to cast iron (spun) pipe embedded in and Including cement concrete blocks 10 x10 x10cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls etc.For 100mm dia. Pipe 48 Providing and fixing heel rest sanitary bend, in 100mm Centrifugally cast (spun) iron pipe S&S 49 Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 100X100X100mm Sand cast iron S&S as per IS : 3989 50 Providing and fixing PLAIN JUNCTIONof required degree 100X100X100mm Sand cast iron S&S as per IS : 3989 51 Providing and fixing terminal guard: 100mm Sand cast iron S&S as per IS - 3989 52 Providing and fixing collar. 100mm Sand cast iron S&S as per IS - 3989 53 Providing and fixingcast iron trap of self cleansing design withcast iron screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors.100 mm inlet and 100 mm outlet,Sand cast iron S&S as per IS: 3989 54 Painting sand cast iron / centrifugally cast iron( spun) iron soil, waste and vent pipes and fittings with paint of any colour such as chocolate, grey or buff etc. over a coat of primer (of approval quality) for new work100mm dia 55 Providing and f1Xing false ceiling at all heights including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS: 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange f1Xed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x1 0x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling f1Xed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c:lc, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light 56 Dismantling of Elevational Features 57 Supply of VRV Variable Refrigerant Flous Outdoor units comprising of Energy efficient Inverter Scroll compreunes (100% were compress) Cooling only Type sunable for Eco Friendly R-410 refrigerant, Variable Speed Condenser fun motur, Air Cooled Condemes, etc. of the following capacities each Cooling only OUTDOOR UNIT 58 Supply of Indoor Units comprising of mulis row deep IDX evaporator coil, electronic expansion device, DIDW Centrifugal blower, etc of thefollowing capacitiesHIWALL Type with Cordless RemoteHIWALL Una-10TR. 59 HIWALL Unit 13TR 60 HIWALL Unit 20TR 61 Corded Remote Controls 62 Y JOINT IDU 63 Y JOINT ODU 64 Positioning, installation, testing of indoor units, outdoor units, fittings(Imported Y-joints & header etc) remote controls of indoor units, complete as per specification and drawings Outdoor Unit 65 Indoor Units Hiwall Type Units 66 Refrigerant Gas Charging (R410A) as per liquid line length in line with Standard 67 Supply, installation, testing and commissioning of High Pressure Interconnecting refrigerant pipe work for VRF System with (19mm/13mm thick) closed cell elastomeric nitrile rubber tubular insulation between indoor & outdoor unita as per specificanons, all piping inaide the room shall be properly supported on Gf Hangers and PVC sleeves shall be provided wherever pipe is crossing the wall. Food Grade Nitrogen is to be used while making brazing joints53.98 mm OD 19 mm thick insulation 68 44.45 mm OD 19 mm thickinsulation 69 41.3 mm OD 19 mm thick insulation 70 34.9 mm OD 19 mm thickinsulation 71 28.6mmOD 19 mm thickinsulation 72 22.2mm OD 19 mm thick insulation 73 19.1 mm OD 19mm thick insulation 74 15.9 mmOD 13 mm thick imsulation 75 12.7 mm OD 13 mm thick insulation 76 9.5 mmOD13 mm thick insulation 77 6.4 mm OD 13 mm thick insulation 78 Supphy Lustallation, testing and commissioning of Hard PVC Dram Pipe MR Suitable for 10 Kg/m2 water pressure including fitings such as elbes spelost, reducer, et insulated with 6 mm thick, tubular nitrile insulation. 25mm dia 79 32 mm dia 80 40 mm dia 81 Providing & fixing control cum transimission wiring between indoor unit and out door unit in PVC Conduits2C X 1.5 sqmm 82 Supply & Laying of MS Slotted Angle for pipes and cables horizontaly and vertically along with threaded rod, nut, bolt, saddle, tie etc. 83 Out Door Unit Lifting & Charge 84 GFRC panels consist of a 1 thick solid concrete skin attached to a 16 gage 2 x 4 steel stud frame system. The overall thickness of this system is typically 7 Studs are typically placed at 2-0 on center and typically have 5/16 diameter galvanized steel pins welded to the steel frame and bounded to the concrete skin. The entire concrete skin and frame system weighs approximately 20 pounds per square foot. The maximum size of a GFRC panel is governed by the material properties, project requirements and shipping limits 85 Outdoor Wall Mounted LED Display Screen 6500 cd/m^2 brightness 6mm pixel pitch of 220V AC 86 Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth including consolidating each deposited layers by ramming, watering etc. stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50m : Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia. 87 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round R.C.C. pipes including bed concrete as per standard design : 150 mm diameter R.C.C. pipe 88 250 mm diameter R.C.C. pipe 89 Providing and fixing square-mouth S.W. gully trap grade A’ complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 100x100 mm size P type With F.P.S. Bricks class designation 75 90 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :150 mm dia rcc pipe 91 250 mm dia rcc pipe 92 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :With F.P.S. bricks with class designation 150 93 Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : With F.P.S. bricks class designation 150 94 Extra for depth for manholes : Size 90x80 cm With common burnt clay F.P.S. (non modular) bricks of class designation 150 95 Size 120x90 cm With common burnt clay F.P.S. (non modular) bricks of class designation 150 96 Wiring point forLight with 1.5sq. mm. FR PVC insulated multistrand single core copper cable in PVC conduit with 1.5 sq.mm. FR PVC-insulated multistrand Copper conductor cable as earth wire drawn in side the conduit. Add for light/fans with moduler type switch. 97 Wiring point for two ways light point with 1.5 sq.mmFRLSH PVC insulated multistrand single core copper conductorcable inSurface/Recessed medium class PVC conduit 2 way modular switch modular plate suitable G.I. Box and earthing the point with 1.5 seq mm FRLS PVC insulated Copper conductor Single core cable etc. as required. 98 Wiring point for Fan/light duty exhaust fan with 1.5sq. mm. FR PVC insulated multistrand single core copper cable in PVC conduit with 1.5 sq. mm. FR PVC-insulated multistrand Copper conductor cable as earth wire drawn in side the conduit. Add for light/fans with moduler type switch. 99 Wiring point for plug with 1.5 sq.mmFRLSH PVC insulated multistrand single core copper conductorcable in PVC conduit pipe Partly concealed in the wall and partly Laid in slabalong with the reinforcement before concreting ,complete with 1.5sqmm. FRLSH PVC insulated multistrand single core copper conductorcable as earth continuity wire , GP box, piano type switch & socket etc.complete in all respect,as directed, including matching colour wash. 100 Wiring point for Exhaust fan with 1.5 sq.mmFRLSH PVC insulated multistrand single core copper conductorcable in heavy gauge PVC conduit pipePartly concealed in the wall and partly Laid in slabalong with the reinforcement before concreting complete with 1.5sqmm. FRLSH PVC insulated multistrand single core copper conductor cable as earth continuity wire , GP box and 15 amp piano type switch & ceiling rose /angle/batten holder on 3mm thick , phenolic laminated backelite sheet etc.complete in all respect,as directed, including matching colour wash. 101 Supply fixing & concealing ofPVC conduit in the wall including cutting of brick laying of conduit & fixing it with MS hooks & then plastering.with cement, sand,mortar finished to the level,with matching colour wash including cost of proper thrading of conduit and providing necessary socket ,bend & chucknuts,as directed by engineer incharge with the supply ofmaterial labour and T&P required for proper completion of work. Size 20 mm dia 16SWG (2 mm)thick 102 Size 25 mm dia 16SWG (2 mm)thick 103 Supply & wiring of submains with 2 nos.1.5 sq.mmFRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm diaheavy gauge PVC conduit partly concealed in wall and partly laid in slab along with the reinforcement before concreting, with1 no. 1.5 sqmm. FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire including matching colour wash etc.complete in all respect. 104 Supply & wiring of submains with 2 nos.2.5 sq.mmFRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia heavy gauge PVC conduit partly concealed in wall and partly laid in slabalong with the reinforcement before concreting, with1 no. 1.5 sqmm. FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire including matching colour wash etc.complete in all respect. 105 Supply & wiring of submains with 2 nos.4 sq.mmFRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia heavy guage PVC conduit partly concealed in wall and partly laid in slab along with the reinforcement before concreting, with 1 no. 2.5 sqmm. FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire including matching colour wash etc.complete in all respect. 106 Supply & wiring of submains with 2 nos.6 sq.mmFRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 25 mm dia heavy gauge PVC conduitpartly concealed in wall and partly laid in slab along with the reinforcement before concreting, with 1 no. 4 sqmm. FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire including matching colour wash etc.complete in all respect. 107 Supply & wiring of submains with 2 nos.10 sq.mmFRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 25 mm dia heavy gauge PVC conduitpartly concealed in wall and partly laid in slab along with the reinforcement before concreting, with 1 no. 6 sqmm. FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire including matching colour wash etc.complete in all respect. 108 Supply & wiring of submains with 4 nos.10 sq.mmFRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 40 mm dia heavy guage PVC conduit partly concealed in wall and partly laid in slab along with the reinforcement before concreting, with 2 no. 6 sqmm. FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire including matching colour wash etc.complete in all respect. 109 Supply & wiring of submains with 4 nos.16 sq.mmFRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 50 mm dia heavy guage PVC conduit partly concealed in wall and partly laid in slab along with the reinforcement before concreting, with 2 no. 10 sqmm. FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire including matching colour wash etc.complete in all respect. 110 Supply and fixing of 63 amp DP 30 mA ELCB/ RCCB of Din Rail mounting in DB complete in all respect with connections as required. 111 Supply & fixing and making connection of 63 amp. 4P 30 mA ELCB/ RCCB of Din Rail mounting in complete in all respect as per direction and satisfaction to the Engineer in Charge. 112 Supply & fixing of Batton/Angle holderincluding makingconnectionetc. as required. 113 Supply and fixing of recess mounting round 15 to 18 Watt LED Down lighiter having powder coated die cast aluminium housing with heat shink,diffuser/reflector and driver set. Complete in all respect. CAT. - AAA 114 Supply and fixing of 2x2 36 W to 46 W indoor recess/surface mounting LED Square Fitting for Armstrong Ceiling having powder coated CRCA housing body diffuser of special polycarbonate material and driver set Complete in all respect. CAT. - AAA 115 Supply and fixing of LED Tube Light with Metal heavy duty Box type batten Light fitting 1X22 watt suitable for upto 1X22 watt LED Polycarbonate tube light complete Including tube suitable for both surface & suspended complete in all respect.CAT. - AAA 116 Supply and fixing of water tight oblong 10 Watt LEDbulk head luminaire having die cast housing with driver set confirming to IP 65 and above Protection.Complete in all respect. CAT. - AAA1100 system lumens, 110 Im/W, PF>0.95 with 5 year warrantee 117 Supply of ceilling fans with fan motor of A.C. Permanent insulation, capacitor rating conforming BEE 5 Star rating and IS:374/79 and also comply with IS:1709/1984 with latest amendment. The rated voltage 220/240 volts,50 Hz, 1-Ph AC the fan assemble should consists of down rod blades, shackle canopies etc and with double ball bearing system.BEE 5 Star rated-1200 mm sweep 118 Supply & Fixing of Factory made 12 to 20 Watt LED Bulb fitting,cool day light,(65000 K temp.) suitable for Batton/Angle holder including makingconnection.Complete in all respect. 119 Supply & Fixing of AC 300mm Sweep, 230/250 Volts, 50 Hz exhaustfan (Heavy Duty) withblades,cover etc. complete as required Cables 120 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc.Following size size 70 sq mm x 3-1/2core 121 Supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed ,underground cable including rubber ring etc. complete in all respect. Thearmouring of the cable shall be properly connected with the earthas per direction of engineer -incharge.for cablesize 70 sq mm x 3-1/2core 122 Supply and fixing ofplain or pin type copper tin plated cable socket (lug) to cable leadsfor pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cable size 70 sq mm 123 Supply and burying of 600mm x 600mm x 6mm G.I. plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and one earthing lead of one no. 8 to 10 SWG GI wire in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in allrespects as per drawing (This will apply for earthing ofpoles also). 124 Supply and laying of 25mm x 3 mm G.I. strip from earth electrode directly in the ground as required complete in all respects. 125 Supply and fixing of two number 8 SWG G.I. wire in 15mm dia. G.I. pipe for earthing, laid in ground or in wall duly concealed including the cost of cement, sand, labour, T&P other material required for proper completion of work as directed at side. 126 Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required. 50 mm dia 127 100 mm dia 128 Supply& Erracetionof factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreise Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release) Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters (KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above insulated with heat shrink sleeving and mounted on non gyroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm.Cubicletype switchboard shall be of cat A & B Only. CAT. B Cubicle Type (AS EMERGENCY COMMON AREA PANEL) Incoming - 129 (or As per requirment directed by Project Manager.) 63 AmpMCB - 6Nos.32 AmpMCCB - 2 Nos.63 Amp MCCB - 1 No.Outgoing - 100 Amp MCCB-1 No.Supply and fixing of 240 volts C Curve6-32 amp SPminiature circuit breaker (10 K A ) in existing MCB, DB complete with connections as required. CAT A 130 Supply and fixing of 240 volts C Curve 40-63amp DP miniature circuit breaker (10 K A ) in existing MCB, DB complete with connections as required. CAT A 131 Supply and fixing of 240 volts C Curve 63 amp4Pminiature circuit breaker (10 K A ) in existing MCB, DB complete with connections as required. CAT A 132 Supply and fixing of80-100 amp 4 pole MCCB(16 KA ) thermal magnetic relese. CAT A 133 Supply and fixing of flush/surface mounting 8 ways TPN distribution boards (Legrand Lexic) without MCB with additional metal doorcomplete in all respects. As directed by engineer incharge. CAT A 134 Supply and fixing of flush/surface mounting 4 ways V TPN distribution board without MCB with additional metal doorcomplete in all respects. As directed by engineer incharge. CAT A 135 Supply & Fixing of MCB blanking plate for DB. 136 Supply and Fixing of Danger Board fabricated from 10 gauge M.S. Sheet as per I.E. Rules 137 Erection and testing of ceiling fan and regulator for room height upto 3.5mts. including supply of 3mm thick G.I. down rod 19mm dia duly painted, complete in all respects. 138 Erection and testing of exhaust fan on the existing hole with suitable size rag bolt nut & washer etc. complete in all respects. 139 Supply and fixing of 16 gauge MS drum duly painted including making hole in the wall for exhaust fan and finshing propely complete in all respect. 140 Supply and Fixing of shock treatment chart.prescribedas per I.E. Rules.duly framed with glass and supported from back with hard board or shoft board with supply of all material ,labour,T&P for proper completion of work. 141 Supply and Laying of 1800*900*12mm thick chequerd rubber matting of tested quality. complete in all respect. as per I.E. Rules 142 Supply and fixing of power plug with 20A/250V flush type Moduler switch and 5 Pin 20A/250V flush type universal Moduler socket in suitable Conceled MS Box including supply of all material, labour,T&P etc.required for proper completion of work. 143 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required. (for Air conditioning/Main incoming.) 144 S/F of hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16SWGM.S. sheet incorporating 10mm dia, M.S. round barduly bent for supporting fan hanger dully painted withred oxide and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting along with supply of all materials, labour T & P etc., for proper completion of work. 145 Supply & Fixing of Moduler switch blanking plate for Moduler switch board. 146 Supply and fixing One/Two module G.I box awlong with moduler base with cover plate. 1 or 2 Module (75mmX75mm) 147 3 Module (100mmX75mm) 148 4 Module (125mmX75mm) 149 6 Module (200mmX75mm) 150 8 Module (125mmX125mm) 151 12 Module (200mmX150mm) 152 Supplyfixingofelectronic fan regulator 120-280 V. ISImarked, on the existing switch board including making connetion, required material, labour T/P etc for proper completion of work to the satisfaction of Engineer in charge of work. 153 Supply and fixing of Three phase multifunctional electronic energy meter 10 to 60 Amp. Capacity fitted in intergral box on wall complete in all respect. 154 Levelling of surface including earth work in surface excavation not exceeding 30cm in depth banking excavated earth in layer not exceeding 20cm in depth breaking clods watering rolling each layer with 1/2 tonne roller, or wooden or steel rammers and rolling every 3rd and top most layer with power roller of minimum 8 tonnes and dressing up in embankments for roads etc with the help of hydraulic excavator, levellors etc complete for required gradient including preparation and consolidation 155 Providing and laying selection first grade grass carpeting at the given area including labour T&P complete 156 Providing and spreading fine sand to the grass work of required thickness 157 Transpotation of Grass etc 158 Supply & mixing of vermicompost with soil including cost of vermicompost & spreading 159 Supply & mixing of manure with soil including cost of manure, transpotation and spreading 160 Providing and Displaying Bougainvillea named variety, Sobhra, Thima, Marry palmar, Cherry Blossom etc. well developed with fresh & healthy bushy in full bloom 75 to 90 cm ht. in 40 cm Cement Pot as per direction of the officer-in-charge 161 Providing and Displaying Bismarckia Palm 115 to 180 cm ht., well developed 12 and above good color fresh and healthy leaves in 40 cm Cement Pot as per direction of the officer-in-charge. 162 Providing and stacking of Cassia fistula (Amaltash) of height 120-135 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge 163 Providing and stacking of Hibiscus rosasinensis of height 90-105 cm., bushy in big size HDPE bag as per direction of the officer-in-charge. 164 Providing and stacking of Tabernaemontana coronaria (Chandni single) of height 90-105 cm.,bushy in big size HDPE bag as per direction of theofficer-in-charge. 165 Providing and stacking of Tecoma stans of height 90-105 cm. bushy in big size HDPE bag as per direction of the officer-in-charge. 166 Digging of hole in soil (0.3x0.3x0.3) Mt. & termite treatment including filling of soil with manure