| 1 | Earthworkinexcavationoffoundationinallkindsofsoil includingmoorum,stonyearthmixedwithboulders(except sheet rocks and boulders requiring blasting) with all leads and lifts including dressing and leveling the bed and depositing the excavated earth at places away from work site with all leads and lifts including cost of all labour and T&P and dewatering if requiredfortheworksetc.completeasdirectedbythe Engineer-in-charge. |
| 2 | Hatchery |
| 3 | Varanda |
| 4 | office room |
| 5 | Supplying, filling in foundation and plinth with sand in 22.5 cm (9”)thicklayersincludingwateringandrammingwithcost, conveyance, royalties and taxes of sand with labour and T&P requiredfortheworketc.complete(Measurementwillbe taken on finished compacted section only). |
| 6 | Hatchery |
| 7 | Varanda |
| 8 | office room |
| 9 | Cement concrete of proportion (1:4:8) in foundation and floors using 4cm (1½”) size clean hard black crusher broken granite stonemetalofapprovedqualityandfromapprovedquarry including hoisting,lowering and laying concrete inlayers not exceeding15cm.(6”)thicktotherequiredlevelramming,watering,curingetc.completeincludingcost,conveyance,royaltiesandexcludingGSTofallmaterialswithalllabour,cessandT&Prequiredfortheworketc.completeinall respect. |
| 10 | Hatchery |
| 11 | Varanda |
| 12 | office room |
| 13 | R.C.C.workM-20grade using20mmand10mmsizeblack hard crusher broken granite chips including hoisting lowering layingandcentringshutteringandfinishingtheexposed surface smooth providing groves or beds wherever necessary includingcost,conveyance,royaltiesandexcludingGSTand costofallmaterialsandlabourwithT&Prequiredforthe worketc.completeinallrespectexcludingthecostofM.S. RodsorTorsteelandbindingwiresandlabourchargefor bending binding and tying grills as directed by the Engineer – in charge in Ground Floor. |
| 14 | Ground floor |
| 15 | (a) Column base |
| 16 | Hatchery |
| 17 | Varanda |
| 18 | office room |
| 19 | (b) Plinth band |
| 20 | Hatchery |
| 21 | Varanda |
| 22 | office room |
| 23 | (c) Lintel |
| 24 | Hatchery |
| 25 | Varanda |
| 26 | office room |
| 27 | (d) Column and beam |
| 28 | Hatchery |
| 29 | Varanda |
| 30 | office room |
| 31 | (e) Bed block |
| 32 | Hatchery |
| 33 | office room |
| 34 | (f) Sun shade and Chajja |
| 35 | Hatchery |
| 36 | office room |
| 37 | (g) Roof Slab |
| 38 | Hatchery |
| 39 | office room |
| 40 | Supplying, fitting andplacinguncoatedHYSDbar reinforcement complete as per drawing and technical specification including cost, conveyance and excluding GST of allmaterialswithlabour, cessand T&Petc. requiredforthe work complete. |
| 41 | Hatchery |
| 42 | Varanda |
| 43 | office room |
| 44 | FlyAshbrickmasonryincementmortar(1:6)inPlinth& Foundation work using fly ash bricks of23cm x 11cm x 8cm sizehavingacrushingstrengthofnotlessthan75kg/cm2 withdimensionaltolerance±2%includingsplayscutting circularmouldingchamferingandcorbelling andsimilarsuch typeofworkswithallnecessaryprojectionswateringand curing including cost, conveyance, royalties and excluding GST of all materials with all labour, cess and T&P required for the work complete in all respect in all floors. |
| 45 | Hatchery |
| 46 | Varanda |
| 47 | office room |
| 48 | FlyAshbrickmasonryincementmortar(1:6)in Super strucutre work using fly ash bricks of23cm x 11cm x8cmsizehavingacrushingstrengthofnotlessthan75kg/cm2withdimensionaltolerance±2%includingsplays cutting circular moulding chamfering and corbelling and similarsuch type of works with all necessary projections watering and curing including cost, conveyance, royalties and excluding GST of all materials with all labour, cess and T&P required for thework complete in all respect in all floors. |
| 49 | Hatchery |
| 50 | Varanda |
| 51 | office room |
| 52 | 6mmthickcementplaster(1:4)toRCCsurfacesfinished smoothincludingcloseddeepchippingandslurrytreatment including watering and curing with cost, conveyance, royalties andexcludingGSTofallmaterialswithalllabourandT&P required for the work etc. complete in all respect. |
| 53 | Hatchery |
| 54 | office room |
| 55 | 12mm(½”)thickcementplaster(1:6)finishedsmoothto outside smooth surface of brick walls after raking out the jointincluding watering and curing with cost, conveyance, royaltiesandexcludingGSTofallmaterialswithalllabourandT&Prequired for the work etc. complete in all respect. |
| 56 | Hatchery |
| 57 | Varanda |
| 58 | office room |
| 59 | 16mm(5/8”)thickcementplaster(1:6)finishedsmoothto inside rough surfaceof 9”/10” thick brick wallsafter rakingoutthejointsincludingwateringandcuringwithcostwithcost, conveyance, royalties and excluding GST of all materialswith all labour, T&P required for the work etc. complete. |
| 60 | Hatchery |
| 61 | Varanda |
| 62 | office room |
| 63 | Supplying, Fitting and fixing Vitrified tiles in Floors of size 600mm x 600 mm of approved make conforming to IS13755 laid on 20mm thickcementmortar[1:4] fillingjoinedwith whitecementofapprovedqualityincludingallmaterials, labour, excludingGST,T&Petc.requiredforthe work all complete as per direction ECI. [For New work only] |
| 64 | Hatchery |
| 65 | Varanda |
| 66 | office room |
| 67 | Fixing Vitrifiedtiles in dados (Printed Series)skirting and risers of stepson 12 mm thick cement plaster(1:3) jointed with neat cement slurry mixed with pigments to matche shade of the tiles including rubbing and polishing completeasper direction of Engineer-in-charge. |
| 68 | Hatchery |
| 69 | Varanda |
| 70 | office room |
| 71 | FinishingwallsurfaceofwallswithAcrylicwallputty(Water based)ofapprovedmakeandfinishedsmoothandeven surface to receive painting including cost of scaffolding staging chargeswithcost ofall materialsexcluding GST, labour T&P etc complete. |
| 72 | Hatchery |
| 73 | Varanda |
| 74 | office room |
| 75 | Wall Priming onecoats on new work with wall water bound primer ofapproved shadeas per direction of Engg-in-Charge. |
| 76 | Hatchery |
| 77 | Varanda |
| 78 | office room |
| 79 | FinishinginsidewallswithDistemperofapprovedshadeon new work two coats to give an even shade including watering and curing with cost, conveyance, royalties and excluding GST of all materials with all labour and T&P required for the work etc. complete in all respect. |
| 80 | Hatchery |
| 81 | Varanda |
| 82 | office room |
| 83 | Painting two coats with weather seal coat paint over a coat of primer with water bound cement paint including cost, conveyance, excluding GST of all materials, labour and T&P etc. complete. |
| 84 | Hatchery |
| 85 | Varanda |
| 86 | office room |
| 87 | Supplying, fitting, fixing up window (sliding type) made up of aluminium section 9778 as window frame section; No 4095. 4096, and 9777, 3994 as shutter frame with 5mm thick black glass as panel fitted with rubber bending including locking arrangement and all fittings including cost of materials, taxes labour, T&P complete.asper direction of Engineer-in-charge. |
| 88 | Hatchery |
| 89 | Supply fitting and fixing MS grill with Iron work wrought and put up in window grating including drilling holes in choukathas etc. complete as per direction of Engg-in-Charge . |
| 90 | Hatchery |
| 91 | Varanda |
| 92 | office room |
| 93 | Enamel Painting two coats with enamel paint over one coat of primer of approved quality etc. complete as per direction of Engg-in-Charge . |
| 94 | Hatchery |
| 95 | Varanda |
| 96 | office room |
| 97 | Supplying , fitting and fixing of grid mineral fibre ceiling board having size 600 mm x 600 mm x 16mm of approved design and quality complete with frame and all fitting and fixtures. |
| 98 | Hatchery |
| 99 | \"Supply fitting and fixing ofA.C. Sheet in roof including fixing of ridges wind ties , nut bolt , washers including all materials and labours as per direction of Engineer-incharge. |
| 100 | Veranda |
| 101 | \"Supplying, fitting and fixing of square MS bar of size 50mm X 50mm including cost of fitting, fixing , conveyance and all taxes etc complete as per direction of Engg-in-Charge. |
| 102 | Veranda |
| 103 | Laying fixing of precast ring of 1.2mtr dia , 0.3mtr heightand 0.05 mtr thick with all fitting. |
| 104 | Site clearance |
| 105 | Sign Board |
| 106 | Laying of 110mm nominal diameter UPVC sewer line including cost of materials. |
| 107 | Supplying, fitting and fixing of 500 liter capacity water storage tank along with construction of appropriate staging for fixing of the same as per specification and direction of engineer in charge. |
| 108 | Providing & Fixing to walls/floor the following nominal diameter pipe, fittings including cost of pipe, making good the damage, etc. |
| 109 | (a)32mm dia PVC pipe in all floors |
| 110 | (b) 20mm dia PVC pipe in all floors |
| 111 | (c) 15mm dia PVC pipe in all floors |
| 112 | Supply, fitting and fixing of chromium plated brass towel rail 25mmdiax450mm long complete including cost of all materials |
| 113 | Supply, fitting and fixing of C.P. screw down bib cock (TAP) of 15mm diameter in ground floor |
| 114 | Supply,fittingandfixingof CPconcealedscrewdownstopcockof15mm diameter. |
| 115 | Supply, fitting and fixing of wash hand basin with hole (size 550x400mm)including fixing CP brass waste, fixing of 32mm PVC waste pipe, fixing 15mm dia CP pillar cocks, fixing 12mm dia connection pipe & water connection etc. complete including cost of all materials in ground floor and first floor as per specification and direction of engineer in charge. |
| 116 | Supply, fitting and fixing of following components/assesories at proper places, all complete in ground floor and first floor as per specification and direction of engineer in charge. |
| 117 | (a ) 110mm pipe clip |
| 118 | (b) 110mm PVC vent cowl |
| 119 | (c) 110 mm dia plain bend |
| 120 | Recssed wiring to light point & Exhaust fan point with 1.5 sqmm FR PVC Insulated single core multistandard copper conductor of ISI marked with 20mm dia non metalic PVC flexible conduit with 5A ,250V modular type switch of ISI marked & ceiling rose of ISI markedmounted on MS BOXhavingfront back light cover of suitable size, MS box with 1.5 sqmm FR PVCinsulated single core multistrand copper conductor and earth wire including all accessories and connection as per direction of Engineer in charge(make of wire=Finollex/L& T/Anchor/Havels/V-guard/Great white)(deducting the cost of S/Fof 100mmx100mmx60mm M.S Box with Backlite cover-1no)Group-A(1.1.1.1-1.24.2) |
| 121 | Ressed wiring to Fan point in Group-B |
| 122 | S/F of 18 SWGfollowing size of modular GI box along with accessories in recess wiring including cutting the wall and making board thesame in case of recess conduit as required(1.24) 2 module. |
| 123 | do.......6 Module |
| 124 | S/F of 5 amp switch and 5A socket( Modular type)out let of make Anchor/Havells on existing board. |
| 125 | Wiring for circuit/sub main wiring alongwith earth wire with following sizes of PVC insulated single core multistrand copper conductor with ISI marked confirming to IS-694/1990 in 20mm dia non metallic heavy duty flexible conduct 1.6mm in recessed PVC conduit as required (Make of wire-Finolex/L & T /Anchor/Havels/V-guard) 2x1.5sqmm + 1x1.5sqmm(1.8.1) |
| 126 | do- 2x2.5sqmm +1x1.5sqmm(1.8.2) |
| 127 | do- 2x4sqmm +1x1.5sqmm(1.8.3) |
| 128 | Supply Installation testing and commissioning of 32A ICDP Main Switchs(IS 13940 part 3/1993) of following capacity on existing surface/wall mounting & complete with H.R.C fuse links inter connections earthig etc as required as per direction of Engineer Incharge (Make-seimens/HPL/Anchor/L & T Havels/C & S/R.K) |
| 129 | 200mmx250mmx75mm deep(1.24.9) for Fixing 32Amp ICDP Main switch |
| 130 | S/F of \"B\" series SP MCB of 6amp rating 240volt B series MCB for lighting and other loads in the existing MCB Distribution board ISI marked complete with connection testing and commissioning etc as required single pole(SP)(2.6.1) |
| 131 | S/F of batten holder BK angle holder ISI marked including connection etc instead of celling rose(1.29-1.28) |
| 132 | S/F of Cu. Earth Plate Earthing 600mmx 600mm x 3.15 Without Salt & Charcol (3.5) |
| 133 | S/F of 8 SWG Copperwire for loop earthing(3.18) |
| 134 | S/f of salt &charcoal for Plate Earth electrode(3.6) |
| 135 | S/F of 3nos 5 amp switch and 3nos 5A socket(modular type) out let of make Anchor/Havells on existing board.(for computer board) |
| 136 | S/ F of18-25LED single strip type tube light fitting( make-Havells/Philips/ Crompton /Polycab/PAC/ HPL) |
| 137 | S/Fof 10Watt LED Bulb ( Make -Crompton/ Havells/ HPL/Philips/Polycab) |
| 138 | Supply & fixing of 48\"\" A.C ceiling fanwithout reguletor incuging numbering of reputed mark inclugingallconnection(Make:-Usha-Striker Millenium/Crompton -jura/ Havells-Velopcity/Spark/Anchor-XL/ Orient -Summer Pride/Polycab -Vital) |
| 139 | S/F of electric step ceiling fan regulater in existing switch box including connetion with 1.5 sqmm FR pvc insulated single core multistrand copper conductor earthing the regulator as required(1.38) |
| 140 | Supply and fitting of 6 mm2 PVC twin core Aluminium wire with G.I wire for service connection. |