Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 30-05-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 06-06-2025 |
| 2 | 20-05-2025 | CORRIGENDUM8862 | BOQ | 30-05-2025 |
| Sl. No. | Item Description |
| 1 | Dismantling wrought iron or mild steel work of any description complete all as directed. |
| 2 | Dismantling of plain or corrugated steel sheeting any guage, thickness including Nanital or similar pattern roof coverings complete all as specified and as directed. |
| 3 | Dismantling of wall and ceiling boards (fiber, pulp, insulation etc.) or insulation boards/slabs/blankets, any thickness, including frames and cover fillets complete all as specified and directed. |
| 4 | Dismantling boarding, any description fixed in any position with nails complete all as specified & directed |
| 5 | Taking down roof trusses, coupled rafters or trussed beams of clear span above 4 mtrs and upto 8 mtrs complete all as specified and as directed. |
| 6 | Dismantling timber scantlings in unframed timber work 40 sq.cm and over in section, in any position complete all as specified and as directed. |
| 7 | Dismantling timber fillets, rails, posts, rafters, purlins, etc in unframed work under 40 Sqcm in section in any posotion complete all as specified & directed. |
| 8 | Demolition of reed, lathing, single or double, including battens and plaster or chicken wire lathing complete all as directed. |
| 9 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars etc. but excluding ashlar facings, dressed stone work & precast concrete articles complete all as specified & directed. |
| 10 | Demolition of unreinforced cement concrete in ground floors and pavings n. exc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 11 | Demolition of reinforced cement contrete of any description in any position not otherwise specifically provided for complete all as specified & directed. |
| 12 | Taking down chowkat or frame with shutters (without taking off shutters from the frame) not exceeding 1.5 sqm each and making good to disturbed surfaces complete all as specified and as directed . |
| 13 | Taking down chowkat or frame with shutters (without taking off shutters from the frame) exceeding 1.5 sqm but not exceeding 4.0sqm each and making good to disturbed surfaces complete all as specified and directed . |
| 14 | M&L for providing reinforced cement concrete Type A-1 1:1 1/2:3 using 20mm nominal size graded crushed stone aggregate as in beams, cantilevers, bressumers,lintels over 1.5m span etc.complete including necessary form work all as specified and directed. |
| 15 | M&L for Form work to sides & soffits of lintels over 1.5m clear span, floor or roof beams, cantilevers, etc for rough finished flat surfaces of concrete complete. |
| 16 | M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as directed. |
| 17 | M & L for mild steel TMT bars 6 mm to 8 mm dia, in stirrups cut to length, bent to shape required, including hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips. Complete all as specified and as directed. |
| 18 | M&L brick work with sub class \"B\" bricks, straight or curved on plan exceeding 6m radius built in cement mortar 1:4 complete all as specified and as directed. |
| 19 | M&L for brick work with sub class old size \"B\" bricks, straight or curved on plan to any radius, built in cement mortar 1:4 as in half brick thick walls complete as specified and directed. |
| 20 | M&L for rendering 15mm thick in CM 1:4 on fair faces of brick or concrete surfaces in two layers 5mm thick finishing layer over 10mm thick backing layerfinished fair and even with mixing water proofing compound to top layer as per manufacturers instruction and as directed (WPC will be measured separetely) complete all as directed |
| 21 | Supply only Integral water proofing compound of approval brand complete all as specified and directed. |
| 22 | M&L for preparation of new plastered surfaces of wall and preparing surfaces as directed by applying thin layer of exterior wall care putty of 1 to 2 mm thick and applying two coats of cement base paint over a coat of primer complete all as specified and directed. |
| 23 | M&L for rendering 10.mm thick plaster in cm 1:6 on fair faces of brick work or concrete surfacesincluding finishing top even and smooth without using extra cement complete all as specified & directed. |
| 24 | M&L for preparation of new plastered surfaces of wall and preparing surfaces as directed by applying thin layer of wall care putty of 1 to 2 mm thick and finally applying two coats of distemper oil emulsion over a coat of primer complete all as specified & directed. |
| 25 | S&F Pressed steel frames (125 x 60mm) for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed. |
| 26 | M&L for plain cement concrete (1:3:6), type C-0, (using 12.5mm graded crushed stone aggregates) as in bed block, blocks for holdfasts,filling in pressed steel door frames , benching slightly rounded or chamfered angles & throating etc including necessary use & waste of form work complete all as specified and directed. |
| 27 | S&F 35 mm thick, flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides & both face is covered with decorative face veneer with lipping / frame to match & fixed to chowkats complete all as specified & directed. |
| 28 | S&F 35 mm thick, hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) fitted to chowkats complete all as specified & directed. |
| 29 | Supply only2nd Class hard wood small fittings such as brackets of any type ,latch and hinge blocks,shaped door and window stops and like ,including all necessary labours,articles n exc 200Cu.cm each complete all as directed. |
| 30 | S&F 200 mm size, aluminium anodised , barrel tower bolts of extruded section & fixed completeall as specified and as directed. |
| 31 | S&F 150mm size aluminium handles, cast type, anodized and fixed complete all as specified & as directed. |
| 32 | S&F 300mm length of bolt, aluminium alloy, anodized,sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified & as directed. |
| 33 | S & F for aluminum powder coated (powder coated of required colour) three track sliding windows frame top & sides of size 92 x 31.75 x 1.50mm (section No 20831) bottom of size 92 x 31.72 x 1.50mm (Soction of 20832) and shutter top & bottom of size 40 x 18 x 1.55 (section 20738) and lock side shutter frame of size 40 x 15 x 1.45mm (Section 20737) with rubber gasket, beading and locking arrangement including making good to the disturbed portion complete including stainless steel wire mesh 0.36mm nominal dia with 1.40mm average aperture and fixed with stainless steel wire staples and fixing 5mm thick glass with necessary rubber beading gasket etc complete all as specified |
| 34 | S & F for Anodised aluminium grill (anodised transparent or dyed to required shade according to IS 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with CP brass/stainless steel screws @ 200mm centre to centre including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening all as specified and directed. |
| 35 | M & L for Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Chief |
| 36 | S & F Aluminium powder coated door shutter single / double leaf, side huge typeon floor door spring (to be paid sepratly), 44.45 mm wide (two panels) fabricated having hanging and meetingstyle 85.00 mm X 44.45 mm x 3mm thick , top rail 83.50 mmx44.45mmx 3mm thick, middle rail 150 mm x 44.45 mm x 2.65 mm thick andbottom rail 150 mm x 44.45 mm x 2.20 mm thick and including jointing cleats, aluminium anodised snap beading, screws, aluminium anodised fittings such as pair of ‘D’ type handle 250 mm long(decorative type), tower bolts 150mm long 1 Nos for each leaf,aluminum beading, PVC packing,locking arrangement with mort ice lock 6 lever and necessary fittings & fixtures complete all as specified and directed by Engineer – in - Charge. |
| 37 | Supply & Fixing mild Steel work in hollow square/rectangular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S. 4923 -1997 (Reaffirmed 2009)grade Yst.-310 complete all as specified and directed. |
| 38 | Supply & Fixing plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment cofirming to Fe 410 -W (Gde- E- 250) quality-A complete all as specified and directed. |
| 39 | M & L for Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, orscrewed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, longbut length of bolt exc 5cm but n exc 10cm long complete all as directed. |
| 40 | M&L for pre-painted hot dip aluminium-zinc alloy metallic coated corrugated steel sheet, any pattern corresponding to IS15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ 150, 0.50mm thick of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed |
| 41 | M&L for hot dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ 150, 0.50mm thick of an approved colour and having yield strength of 550MPa as in ridge/valley/gutter/eaves boardings fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed. |
| 42 | Providing and fixing inter locking metal grid (snap grid for false ceiling) of size 605mm x 605mm in true horizonatal level, hot dipped galvanised steel sections consisting of main “T” runner with suitably spaced joints to get required length and size 24mm x 38mm made from 0.30mm thick (Min) sheet spaced at 1200mm centre to centre and cross “T” of size 24mm x 28mm made of 0.30mm thick (Min) sheet, 1200mm long spaced between main “T” at 600mm centre to centre to form a grid of 1200mm x 600mm and secondary cross “T” of length 600mm and size 24mm x 28mm made of 0.30mm thick (Min) sheet to be interlocked at middle of the 1200mm x 600mm panel to form grids of 600mm x 600mm and wall angle of size 24mm x 24mm x 0.4mm. Main “T” runner to be suspended from purlins or truss member using 2 to 3 mm dia GI wire, 1200mm x 600mm centre to centre all complete for all heights as per specifications and as directed |
| 43 | M & L for 4 mm thick high pressure, oceanic pre-primed, self embossed, non asbestos fibre cement decorative board, water, termite and fire resistant for insulation ad acoustic purpose to be placed in grid system hold down clips with provision of high fixtures, air conditioning, diffuser and ducts, sprinkler, smoke detector etc, complete all as per manufacturer instructions |
| 44 | S & F steel windows with side hung shutters including projecting type hinges with steel handle, and steelpeg stay, complete with glazing bars, dovetailed or weldedcomplete all as directed |
| 45 | S & F steel ventilator with top hung shutter including hinges, steel peg stay, complete all as directed |
| 46 | M&L for 50 mm thick Cement concrete type C-1, 1:3:6 (using 20 mm graded stone aggregates) as in plinth protection etc, finishing cement concrete surface even and smooth with out using extra cement including making joints with hot bitumastic mix in proportion of bitumen and sand 1:2 complete as specified & directed. |
| 47 | S &F2.5mm to 3mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as directed . |
| 48 | M& L for 40 mm thick PCC type B-0 using 12.5 mmgraded aggregate as inflooring finished even and smooth with using extra cement complete all as directed. |
| 49 | S & F framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framedguard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as directed |
| 50 | M&L for coloured non skid joint free ceramic tiles of 7mm to 8mm thick (squire / rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 sqm in floors, etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in cement mortar 1:6 for laying floor finishes complete all as specified & directed. |
| 51 | M&L for coloured non skid joint free ceramic tiles of 7mm to 8mm thick area of each tile exceeding 0.18 Sqm but not exceeding 0.38 sqm in floors, etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over andincluding 10mm thick renderingin cement mortar 1:4 for vertical surfaces such as skirting etc complete all as specified & directed. |
| 52 | M&Lglazed ceramic coloured tiles in vertical surface 350x250x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over and inclusding rendering 10mm thick on fair faces of brick work or concrete surfaces in CM (1:4) as in screed bed of wall tiles complete all as specified and directed. |
| 53 | M&L for preparing new wood & wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified & directed. |
| 54 | M&L for preparation of new or previously steel surfaces of any description, over 10 cm width or girth, not otherwise described and evenly applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 55 | M&L for preparation of old painted or plastered surfaces of walls etc by washing, rubbing down and applying one coat of cement base paint complete all as specified & directed. |
| 56 | M&L Prepration of newly plastered surface of wall and applying two coat of cement base paintcomplete all as directed |
| 57 | M&L for preparation of new plastered surfaces of wall and applying three coat of white wash complete all as specified & directed. |
| 58 | M& L forPCC 1:4:8,type D2 (using 40 mmgraded aggregate) as in foundations, fillingsand mass concrete complete all as directed |
| 59 | S & F 3mm thick, 38mm wide glass dividing strips, inserted in position, conform to design complete all as directed |
| 60 | M&L for hardcore of gauge n exc. 63 mm, with using broken stone or boulders , deposited, spread and levelled in layers n exc. 15cm thick, watered and rammed to a true surface complete all as directed |
| 61 | M&L for 100mm thick PCC1:2:4, type B2 (using 40mm graded stone aggregate) as in path finished the surface by making impressions of expanded metal, whilst the concrete is green complete all as directed |
| 62 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft /loose soil complete all as directed |
| 63 | Returning, filling in, includingspreading, levelling, watering and well ramming in layers not exc 25 cm in soft /loose soil complete all as directed |
| 64 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as directed |
| 65 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, complete all as directed |
| 66 | S&F 15mm bore chromimum plated bib taps,cast copper ally with crutch or butterfly handle,screwed for iron pipe or brass ferrulecomplete all as directed |
| 67 | S&F in repair, Wash basins white, vitreous China, flat back, size 580x450mm,excluding taps, waste, chain and plug and porcelain stopper but including bracketsfixed to wall complete all as specified & directed. |
| 68 | S&F in repair PVC connection 15mm size with PTMT nuts of length 600mm complete all as specified & directed. |
| 69 | S&F in repair 32mm waste coupling of PTMT (half or full threaded) (minimum weight 40mm-60 gms) fixed complete all as specified and as directed. |
| 70 | S&F in repair 600mm x 450mm looking mirror of 4to 5mm thick selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers fixed complete all as specified and as directed. |
| 71 | S&F soap dish of stainless steel fixed to wall with chromium plated brass screws fixed in repair complete all as specified &directed. |
| 72 | S&F stainless steel tubular towel rail 600 mm long with brackets 20 mm dia fixed to wall with chromium plated brass screws fixed in repair complete all as specified &drected. |
| 73 | S&F in repair, fancy type 15 mm dia pillar taps, cast copper alloy with capstan heads, chromium plated, screwed down high pressure, with or without lettered \"Hot\" or \"Cold\" with long screwed shanks & fly nuts, screwed for iron pipe & fixed complete all as specified & as drected.. |
| 74 | S&F 32 mm bore low density polyethylene pipes (LDPE) of pressure rating 6 kg / cm2 as in waste ppes for wash hand basin etc complete all as directed |
| 75 | S&F PVC (SWR) pipes 75mm diasingle socketed, in any length with rubber ring joints, fixed to walls complete all as specified and as directed. |
| 76 | Surface excavation30cm deep and getting out in soft/loose soil complete all as specified and directed. |
| 77 | M&L brick work with sub class \"B\" bricks, straight or curved on plan exceeding 6m radius built in cement mortar 1:6 complete all as specified and as directed. |
| 78 | M&L Antitermite treatmanet treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as directed |
| 79 | Material & Labour forPCC 1:3:6 type C2 using 40mm graded aggregate as in foundation, filling, sub base etccomplete all as specified and as directed. |
| 80 | M & L Forming embankments includingraising (or lowering) earth, spreading in layers n exc. 30 cm thick;watering, ramming/rolling and finishing to required size, shape,etc., n exc. 1.5m high from base complete all as specified. |
| 81 | Taking down aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as directed. |
| 82 | M&L for Point wiring complete as specified with 1100 volt grade 1.5 sq.mm. (nominal area) single core PVC insulated unsheathed cable multi-stranded copper conductor drawn through and including PVC casing and capping of suitable size but not less than 20mm, with all fittings, fixed on wall/ceiling /floor including modular box suitable for housing modular pattern switches/ sockets/ regulators etc.and duly earthed with same cable as for wiring above but green in colour as continuous earthing wire complete all as specified & directed for :-(a) One light /Fan /Ex Fan point controlled by one, one way switch(b) One socket outlet 3 or 5 Pin, 6 Amp on independent board |
| 83 | All as per Ser item No 82.00 above but with 1.5 sqmm copper cable in and including PVC casing and capping complete all as specified and as directed for One socket outlet 3 or 5 Pin, 6 Amp on same board. |
| 84 | All as per Ser item No 82.00 above but with 2.5 sqmm copper cable in and including PVC casing and capping complete all as specified and as directed for socket outlet 3 or 6 pin 15 Amps. |
| 85 | M&L for Point wiring complete as specified with 1100 volt grade 1.5 sq.mm. (nominal area) single core PVC insulated unsheathed cable multi-stranded copper conductor drawn through and including surface type rigid non-metallic PVC conduitof suitable size but not less than 20mm dia , with all fittings, fixed on wall/ceiling /floor including modular box suitable for housing modular pattern switches/ sockets/ regulators etc. and duly earthed with same cable as for wiring above but green in colour as continuous earthing wire complete all as specified & directed for :-Note :- (i) Modular Plates & Covers and Modular Metal Boxes/PVC Boxes shall deemed to be included in the quoted rates..(ii) Necessary PVC rigid junction boxes for identifying junction as required on site/directed by Engr-in-charge for point wiring work with PVC dummy plates shall deemed to be included in the quoted rate.(iii) The wiring shall be done strietly by following proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads.(a) One light /Fan /Ex Fan point controlled by one, one way switch |
| 86 | S&F modular switch 6 Amp one way 1 module 230 V AC complete all as specified and directed. |
| 87 | S&F modular switch 16 Amp one way 1 module230 V AC complete all as specified and directed. |
| 88 | S&F modular socket outlet 6Amp 2 module intel multi socket for all pins 230 V AC complete all as specified and directed. |
| 89 | S&F modular socket outlet 16 Amp 2 module and 6/16 Amp heavy duty 230 V AC complete all as specified and directed. |
| 90 | S&F modular ceiling fan regulator, electronic step type, 5 speed AC 230 volts, 2 module complete all as specified and directed. |
| 91 | S&F 3 module Metal Flush Box including white cover plate with frame for fixing of modular switeches/sockets etc. complete all as specified and directed by Engineer-in-charge. |
| 92 | S&F 4 module Metal Flush Box including white cover plate with frame for fixing of modular switeches/sockets etc. complete all as specified and directed by Engineer-in-charge. |
| 93 | S&F 6 module Metal Flush Box including white cover plate with frame for fixing of modular switeches/sockets etc. complete all as specified and directed by Engineer-in-charge. |
| 94 | S&F 8 module Metal Flush Box including white cover plate with frame for fixing of modular switeches/sockets etc. complete all as specified and directed by Engineer-in-charge. |
| 95 | S&F ceiling rose, three terminal, PVC/polycarbonate, isolated body, ISI markedcomplete all as specified and as directed. |
| 96 | S&F LED Tube lights fitting 1 x 18/20 Watt, 4 feet ,220V AC decorative box type with driver, holder including fitting fixed on wall/ceiling and connecting up complete with 3 core flexible cable white of suitable size and making necessary connection complete all as specified and directed. |
| 97 | Fixing only serviceable LED Tube lights fitting 1 x 18/20 Watt, 4 feet ,220V AC obtained from taking down complete all as directed |
| 98 | S&F Aesthetically designed recessed mounted panel 1x1 Feet LED light 18/24 Wattflatround/square type for surface/ceiling mounting which provides soft-light and glare free symmetrical illumination as fixed in repairsincluding taking down old unsv light fitting all as specified and directed. |
| 99 | S&F LED Tube lights fitting 1 x 9/10 Watt, 2 feet , 220V AC decorative box type with driver, holder including fitting fixed on wall/ceiling and connecting up complete with 3core flexible cable white of suitable size including taking down old unsv tube light fitting and making necessary connection complete all as specified and directed. |
| 100 | S&F PVC/polycarbonate angular type Lamp Holder for table lamp insulated body with back plate angle type suitable for battencomplete all as specified and directed by Engr-in-charge . |
| 101 | S&F LED building security light fitting 1 x 35 Watt new generation energy saving and environmental friendly long life LED street light made up of pressure diecast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP65 protectionincl mounting bracket of suitable size and connection complete all as specified and directed. |
| 102 | S&F LED Bulk head fitting 10 watt in engineering plastic housing with clear prismatic diffuser complete with all accessories internally pre-wired and fixed to walls/ceiling on PVC Box with screw including connecting up with twin coreflexible copper conductor cable with suitable size, including taking down old unsv fitting complete all as specified and directed. |
| 103 | Taking down carefully old unserviceable ceiling fans / Exhaust fans complete, removing its blade and deposit to the MES Store yard/Keep in safe custody incluidng refixing after necessary repair works. |
| 104 | Over hauling of ceiling fan of any sweep/ make i.e. opening of fan and cleaning ball bearing, filling grease/ oil and changing of u/s cotter pin, nut, screw, check nuts and bolts as required incl. cleaning of body, blades, down rods, canopies etc and re-assembling andpaintingcomplete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust complete all as directed. |
| 105 | Hanging only ceiling fan any make/ sweep and connecting up with existing electric circuit complete received from MES Store Yard all as specified and directed. |
| 106 | S&F ceiling fans 1200 mm sweep, AC 230 V complete with blades, down rods andconnected accessories, Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with (BLDC) brushless direct current motor and connection complete all as specified and directed. |
| 107 | S&F Exhaust fans made of sturdy Engineering plastic/Metal complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm and connecting up including louvers including making necessary opening on stone /brick masonry wall of suitable size, finishing it properly and making good with matching colour with the surroundings provision of cable 3 core ofof suitable size from ceiling rose to fan complete all as specified and as directed. |
| 108 | M&L for providing concealed sub main wiring with two single core 4.00 Sqmm (nominal area) PVC Insulated FRLSH unsheathed multi stranded copper conductor cable 1100 volts grade drawing through PVC Conduit as per direction complete including 4.00 Sqmm PVC insulated unsheathed multi stranded FRLSH single core copper conductor cable for earth wire including taking down/removing old one & cutting chases in walls by cutterand making good distrubed surfaces of walls, floors, etc complete all as specified and directed. Note :- (i) Three runs of single core 4.00 Sqmm multi stranded copper cable and one run of PVC conduit shall be measured as one run length (ii) Extra length of cable required for connection to DBs/MCBs shall deem to be included in unit rate quoted by contractor against the item (iii) Earth wire run inside the conduit. |
| 109 | Supply & fixPrewired Distribution Board factory made sheet metal enclosure double door distribution board class IP-43 IK 09 with 200 Amp rated copper bus bar 240 Volts 12 way (2 + 10 way) single pole and neutral link, incl taking down old u/s any type, complete all as specified and as directed. |
| 110 | S&F single pole and neutral DB wall mounting type, 240 Volts,8 Way with 200 Amps rated bus bar, double door suitable for fixing MCB\"s including connecting etc and taking down U/S DB ,main switch complete. |
| 111 | S&F single pole and neutral DB wall mounting type, 240 Volts,4 Way with 200 Amps rated bus bar, double door suitable for fixing MCB\"s including connecting etc and taking down U/S DB ,main switch complete. |
| 112 | S&F MCB single pole and neutral (SP&N) 40 Amp 240 volts 10 KA \"C\" series with all incoming/outgoing connections with proper size lugs including taking down old unserviceable, complete all as specified and directed. |
| 113 | S&F MCB single pole and neutral (SP&N) 32 Amp 240 volts 10 KA \"C\" series with all incoming/outgoing connections with proper size lugs including taking down old unserviceable, complete all as specified and directed. |
| 114 | S&F MCB single pole (SP) 6 to 32 Amp 240 Volts 10 KA \"C\" series with all incoming/outgoing connection with proper size lugs including taking down old unserviceable complete all as specified and directed. |
| 115 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 2 core, complete including taking down old u/s service wire. |
| 116 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core, complete including taking down old u/s service wire. |
| 117 | M&L for brick protection over cables inside the trench by using common burnt clay building bricks,sub-class\"B\" laid dry and flat and width wise along the axis of the trench complete all as specified and as directed by Engineer-in-Charge. |
| 118 | M&L for sand cushioning in cable trenches over & under the cables, with river washed coarse sand, as per standard practice with proper compaction complet all as specified anddirected by Engr-in-Charge. (Punned thickness shall be considered for payment). |
| 119 | M&L for light grade galvanized pipe ISI marked with all fitting ISI marked, laid in trenches, under road or fixing on wall/pole/ crossing nallahetc of bore40 mm complete all as specified and as directed . |
| 120 | Boring of holes under road, pavement, hard standing by trenchless technologytechnique for 40-80 mm dia pipecomplete all as directed |
| 121 | Material and labour for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to galvanized iron earth lead wire 4mm dia, (main earthing lead ) by means of galvanized bolts, nuts and washers all as shown in electrical plate no 5 of MES Schedule Part-I (1991) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe light grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia light grade for watering pipe with funnel & wire meshincluding necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick pre-cast RCC cover in 1 : 2 : 4 type B1 with 3 Nos 8 mm dia TMT bars both ways completeall as specified & directed. |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy