| 1 | Making plinth protection 50 mm thick of cement concrete 1:3:6 (one cement : three coarse sand (zone - III) : six graded stone aggregate 20 mm nominal size) over 75 mm (seventy five milimetre) thick bed of dry brick ballast 40 mm (forty mimi metre) nominal size, well rammed and consolidated and grouted with fine sand, including carriage of materials with in all leads, lifts and other incidentals complete in all respect as per direction and to the entire satisfaction of Engineer-in-Charge. |
| 2 | Reinforcement cement concrete work in arches, archribs, domes, vaults, shells, folded plate and roofs having slope more than 15° (fifteen degree) up to all floor level excluding the cost of centring, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) mechanically mixed vibrated and curing complete including carriage of materials with in all leads, liftand other incidentals as per direction and to the entire satisfaction of Engineer-in-Charge. |
| 3 | Providing form work with steel plates 3.15 mm ( three point fifteen millimetre ) thick welded with angle iron in frame 30x30x5 mm (Thirty millimetre x Thirty millimetre x five millimetre) so as to give a fair finish including centering, shuttering, strutting and propping etc. with wooden battens and ballies in any height of propping and centering below supporting floor to ceiling upto floor all level and removal of the same for in-situ reinforced concrete and plain concrete work including carriage of materials with in all leads, lifts and other incidentals or as per direction of Engineer-in-charge in:- |
| 4 | Lintels, beams, plinth beams, girders,bressumers and cantilevers. |
| 5 | Columns, pillars, posts and struts square, rectangular or polygonal in plan as required. |
| 6 | Edges of slab and breaks in floor and walls under 20 cm wide as required. |
| 7 | Providing tor steel reinforcement for R.C.C. work TMT bars of grade Fe-500 D or more ISI make high yield strength for reinforced cement concrete work includingstraightening, cutting ,bending, binding and placing in position and cost of binding wire complete up to floor all levels including carriage of material with in all leads, lifts and other incidentals completeas per direction and to the entire satisfaction of Engineer-in-Charge. |
| 8 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor all level in all shapes and sizes in cement mortar 1:6 (one cement : six sand) including curing complete and carriage of materialwith in all leads,lifts and other incidentals, completeas per direction and to the entire satisfaction of Engineer-in-Charge. |
| 9 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up tofloor all level in cement mortar 1:4 (one cement : four sand) including curing complete and carriage of material within all leads, lifts and other incidentals, completeas per direction and to the entire satisfaction of Engineer-in-Charge. |
| 10 | Providing and fixing 18 mm thickgranite stone, gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all level. Area of slab over 0.50 sqm. including carriage of materials with in all leads, liftsand other incidentals as per direction and to the entire satisfaction of Engineer-in-Charge. |
| 11 | Providing edge moulding to 18 mm thick granite stone, marble or kota stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge including carriage of materials with in all leads, lifts and other incidentals. |
| 12 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete including carriage of materials with in all leads, lifts and other incidentals. |
| 13 | Providing second class deodar wood work in frames of doors, windows, clerestory, windows and other frames wrought, framed and fixed in position, as required including carriage of materials with in all leads, lifts and other incidentals. |
| 14 | Providing and fixing 40 mm( forty millimeters) thick panelled glazed or panelledand glazed shutters for doors, windows and clerestory windows including black enameied iron butt hinges with necessary screws ofsecond class deodar woodincluding carriage of materials with in all leads, lifts and other incidentals. |
| 15 | Providing and fixing 40mm(forty millimeters )thick wire gauge shutters for doors windows and clerestory windows, using galvanized MS wire gauge of IS gauge desigination85 G with wire of dia 0.56mmincluding black enameled iron butt hinges with necessary screws of second class deodar wood including carriage of material with in all leads , lifts and other incidentals |
| 16 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick complete including carriage of materials with in all leads, lifts and other incidentals. |
| 17 | 5 mm thick glass pans (weight not less then 12.5 kg/sqm) |
| 18 | Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured). including carriage of materials with in all leads, lifts and other incidentals. |
| 19 | Providing and fixing ISI marked flush door shutters 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws etc. conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters including carriage of materials with in all leads, lifts and other incidentals. |
| 20 | Providing extra for lipping with 2nd class teak wood battens 25 mm (twenty-five milimetre) minimum depth on all edges of flush door shutters (over all area of door shutter to be measured)completeincluding carriage of materials with in all leads, lifts and other incidentals. |
| 21 | Providing extra for cutting rebate in flush door shutters (Total area of the shutter to be measured) completeas per direction and to the entire satisfaction of Engineer-in-Charge. |
| 22 | Providing and fixing teak wood wooden moulded beading 50x12mm (fifty X twelve milimetre)to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete including carriage of materials with in all leads, lifts and other incidentals. |
| 23 | Providing and fixing M.S. grills fixed to openings /wooden frames with rawl plugs screws etc. of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete including carriage of materials with in all leads, lifts and other incidentals. |
| 24 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15 cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including carriage of materials with in all leads, lifts and other incidentals. |
| 25 | Providing and fixing Stainless Steel extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete including carriage of material with in all leads, lifts and other incidentals. |
| 26 | Providing and fixing bright finished stainless steel sliding door bolts, ISI marked with nuts, bolts & screws completewith in all leads, lifts and other incidentals. |
| 27 | 300 x 16 mm (three hundred X sixteen mili metres) |
| 28 | 200 x 16 mm (two hundred X sixteen mili metres) |
| 29 | Providing and fixing bright finished stainless steel tower bolts, ISI marked with screws completewith in all leads, lifts and other incidentals. |
| 30 | 200 x 10 mm (two hundred X ten mili metres) |
| 31 | 150 x 10 mm (one hundred fifty X ten mili metres) |
| 32 | Providing and fixing 50 cm long Stainless Steel kicking plate of size 100x3.15 mm,to required colour or shade, with necessary screws etc. completewith in all leads, lifts and other incidentals. |
| 33 | Providing and fixingstainless steel handles, ISI marked with screws completewith in all leads, lifts and other incidentals. |
| 34 | 150 mm (one hundred fifty milimeter) |
| 35 | 200 mm (two hundredmilimeter) |
| 36 | Providing and fixing twin rubber stopper Stainless Steel hanging floor door stopper, ISI marked, with necessary screws etc. complete. with in all leads, lifts and other incidentals. |
| 37 | Providing and fixing bright finished Stainless Steel casement stays (straight peg type) , with necessary screws etc.complete.200mm weighing not less than 240gms |
| 38 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including carriage of materials with in all leads, lifts and other incidentals. |
| 39 | Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primeras requiredincluding carriage of materials with in all leads, lifts and other incidentals as per direction by the Engineer-in-Charge. |
| 40 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including carriage of materials with in all leads, lifts and other incidentals as per direction by the Engineer-in-Charge. |
| 41 | 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete including carriage of materials with in all leads, lifts and other incidentals as per direction by the Engineer-in-Charge. |
| 42 | 18 mm thick Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. |
| 43 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete including carriage of material with in all leads, liftsand other incidentalsas per direction and to the entire satisfaction of Engineer-in-Charge. |
| 44 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. including carriage of material with in all leads, liftsand other incidentals as per direction and to the entire satisfaction of Engineer-in-Charge. |
| 45 | Providing and laying vitrified floor tiles600 mm x 600 mm x 10 mmwith water absorption less than 0.08 % and conforming to IS: 15622, of approved make Kajaria/Nitco/Jonson tiles in all colours and shades, laid on 20 mm thick cement mortar 1:4 (one cement : four coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc. complete including carriage of material within all leads, liftsand other incidentals as per direction and to the entire satisfaction of Engineer-in-Charge. |
| 46 | Providing and laying Vitrified tiles 600 mm x 600 mm x 10 mm with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make Kajaria/Nitco/Jonson tiles in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (one cement : three coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete including carriage of materials with in all leads, liftsand other incidentals as per direction and to the entire satisfaction of Engineer-in-Charge. |
| 47 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. including carriage of materials with in all leads, lifts and other incidentals. |
| 48 | Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 49 | Providing and fixing 0.60 mm ( zero point sixty milimeters) thick prepainted steel sheet inroofingwith hot dipped metallic zink coated sheet with top coat of regular modified polyster ( RNP ) organic coating of 20 microns over 5 microns primer coating to back coat of polyster of 5 microns over 5 microns primer coating including fixing with prepainted screwscomplete with all accesoriees as per the directon of engineer in charge including carriage of material with in all leads, lifts and other incidentals. |
| 50 | Providing and fixing ridges or hips 60 cm over all with 0.60 mm ( zero point sixty milimeters) thick prepainted steel sheet inroofingwith hot dipped metallic zink coated sheet with top coat of regular modified polyster ( RNP ) organic coating of 20 microns over 5 microns primer coating to back coat of polyster of 5 microns over 5 microns primer coating including fixing with prepainted screwscomplete with all accesoriees as required as per the directon of engineer in charge including carriage of material with in all leads lifts in all floors. |
| 51 | Providing and fixing valley 60 cm over all 0.60 mm ( zero point sixty milimeters) thick prepainted steel sheet inroofingwith hot dipped metallic zink coated sheet with top coat of regular modified polyster ( RNP ) organic coating of 20 microns over 5 microns primer coating to back coat of polyster of 5 microns over 5 microns primer coating including fixing with prepainted screws /J or L hooks, bolts and nuts 6 mm dia withprepainted GI limpet and bitumen washers complete with all accessoriesincluding carriage of material with in all leads lifts in all floors as required as per the directon of engineer in charge. |
| 52 | Providing and fixing M.S BPsheet 1.66 mm to 2 mm thick in eavesboard / facia / soffit / ceiling including cutting fixingand welding to steel roof members and applying a coat of red lead primer complete as per the instructions of engineer in charge ( base members of steel workshall bemeasured and paid separtelyincluding carriage of material with in all leads lifts in all floors as required as per the direction of Engineer-in-charge. |
| 53 | Providing and fixing Single socketed pipes 110 mm dia (one hundred ten mili metre) with minimum pressure of 4.5 kg/sqm on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, including carriageof materials with in all leads, lifts and other incidentals. |
| 54 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories of working pressure 4 Kgf/sq cm for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion including carriage of material in all leads & lifts and other incidentals. |
| 55 | 110 mm bend (one hundred ten mili metres) |
| 56 | 110 mm shoe (one hundred ten mili metres) |
| 57 | Providing and fixing 110 mm diameter (one hundred ten mili metres) unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm (fifty X fifty X fifty milimetres) hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (one cement : four coarse sand) and making good the wall etc. complete. including carriage of material with in all leads, lifts and other incidentals. |
| 58 | 6 mm (six millimeter) thick cement plaster to ceiling in cement mortar 1:3 (one cement : three sand) including carriage of material with in all leads, lifts and other incidentals. |
| 59 | 15 mm (fifteen millimeter) thick cement plaster in single coat on rough / fair side of brick /concrete / stone wall for interior plastering for all floors including arises internal roundedangles chafers and / or rounded angles chamfers and / or rounded angles not exceeding 80 mm (eighty millimeters )In girth and finished even and smooth in cement mortar 1:6 (one cement : six sand ) including carriage of material within all leads, liftsand other incidentals as per direction and to the entire satisfaction of Engineer-in-Charge. |
| 60 | Providing and applying white cement based putty of average thickness 1 mm (one milimeter), of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth completeincluding carriage of material within all leads, liftsand other incidentals as per direction and to the entire satisfaction of Engineer-in-Charge. |
| 61 | Distempering two coats with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 (fifty) grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. including carriage of material within all leads, liftsand other incidentals as per direction and to the entire satisfaction of Engineer-in-Charge. |
| 62 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10sqm) including carriage of material with In all leads, lifts in all floors and other incidentals completes as per direction and to the entire satisfaction of Engineer-in-Charge. |
| 63 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.75 ltr/10 sqm of approved brand and manufacture including carriage of material within all leads, liftsand other incidentals as per direction and to the entire satisfaction of Engineer-in-Charge. |
| 64 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture including carriage of material within all leads, liftsand other incidentals as per direction and to the entire satisfaction of Engineer-in-Charge. |
| 65 | Melamine polishing on wood work (one or more coat) including carriage of material within all leads, liftsand other incidentals as per direction and to the entire satisfaction of Engineer-in-Charge |