Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 30-05-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 06-06-2025 |
| 2 | 20-05-2025 | CORRIGENDUM8864 | BOQ | 30-05-2025 |
| Sl. No. | Item Description |
| 1 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars etc. but excluding ashlar facings, dressed stone work & precast concrete articles complete all as specified & directed. |
| 2 | Dismantling of wall and ceiling boards (fiber, pulp, insulation etc.) or insulation boards/slabs/blankets, any thickness, including frames and cover fillets complete all as specified and directed. |
| 3 | Demolition of unreinforced cement concrete in ground floors and pavings n. exc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 4 | Taking down chowkat or frame with shutters (without taking off shutters from the frame) not exceeding 1.5 sqm each and making good to disturbed surfaces complete all as specified and as directed . |
| 5 | Taking down chowkat or frame with shutters (without taking off shutters from the frame) exceeding 1.5 sqm but not exceeding 4.0sqm each and making good to disturbed surfaces complete all as specified and directed . |
| 6 | M&L for brick work with sub class old size \"B\" bricks, straight or curved on plan to any radius, built in cement mortar 1:4 as in half brick thick walls complete as specified and directed. |
| 7 | M&L brick work with sub class \"B\" bricks, straight or curved on plan exceeding 6m radius built in cement mortar 1:4 complete all as directed. |
| 8 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water etc |
| 9 | M&L for rendering 15mm thick in CM 1:4 on fair faces of brick or concrete surfaces in two layers 5mm thick finishing layer over 10mm thick backing layerfinished fair and even with mixing water proofing compound to top layer as per manufacturers instruction and as directed (WPC will be measured separetely). |
| 10 | Supply only Integral water proofing compound of approval brand complete all as specified and directed. |
| 11 | M&L for preparation of new plastered surfaces of wall and preparing surfaces as directed by applying thin layer of exterior wall care putty of 1 to 2 mm thick and applying two coats of cement base paint over a coat of primer complete all as specified and directed. |
| 12 | M&L for rendering 10.mm thick plaster in cm 1:6 on fair faces of brick work or concrete surfacesincluding finishing top even and smooth without using extra cement complete all as specified & directed. |
| 13 | M&L for preparation of new plastered surfaces of wall andapplying three coats of white wash complete all as specified & directed. |
| 14 | S & F expanded metal, cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members |
| 15 | M&L for plain cement concrete (1:3:6), type C-0, (using 12.5mm graded crushed stone aggregates) as in bed block, blocks for holdfasts,filling in pressed steel door frames , benching slightly rounded or chamfered angles & throating etc including necessary use & waste of form work complete all as specified and directed. |
| 16 | M&L for Providing and fixing inter locking metal grid (snap grid for false ceiling) of size 605mm x 605mm in true horizonatal level, hot dipped galvanised steel sections consisting of main “T” runner with suitably spaced joints to get required length and size 24mm x 38mm made from 0.30mm thick (Min) sheet spaced at 1200mm centre to centre and cross “T” of size 24mm x 28mm made of 0.30mm thick (Min) sheet, 1200mm long spaced between main “T” at 600mm centre to centre to form a grid of 1200mm x 600mm and secondary cross “T” of length 600mm and size 24mm x 28mm made of 0.30mm thick (Min) sheet to be interlocked at middle of the 1200mm x 600mm panel to form grids of 600mm x 600mm and wall angle of size 24mm x 24mm x 0.4mm. Main “T” runner to be suspended from purlins or truss member using 2 to 3 mm dia GI wire, 1200mm x 600mm centre to centre all complete for all heights as per specifications and as directed |
| 17 | M & L for 4 mm thick high pressure, oceanic pre-primed, self embossed, non asbestos fibre cement decorative board, water, termite and fire resistant for insulation ad acoustic purpose to be placed in grid system hold down clips with provision of high fixtures, air conditioning, diffuser and ducts, sprinkler, smoke detector etc, complete all as per manufacturer instructions |
| 18 | M&L for coloured non skid joint free ceramic tiles of 7mm to 8mm thick area of each tile exceeding 0.18 Sqm but not exceeding 0.38 sqm in floors, etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including including 15mm thick screed bed or bedding layer in cement mortar 1:6 for laying floor finishes complete all as specified & directed. |
| 19 | M&L for coloured non skid joint free ceramic tiles of 7mm to 8mm thick area of each tile exceeding 0.18 Sqm but not exceeding 0.38 sqm in floors, etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick renderingin cement mortar 1:4 for vertical surfaces such as skirting etc complete all as specified & directed. |
| 20 | S&F mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conforming to Fe 410-W (Gde- E- 250) quality-A |
| 21 | S&F1mm thick mild steel plain black sheet in hearths; covering to door shutters; covering to door chowkats (frames); chullah hoods; water tanks; water troughs; ducts; urinal troughs and funnels, etc. cut to size edges beaded if directed, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel members, etc., with plain 40 mm lap joints or welded/ riveted seams including bending, turning up,mitred angles, stopped ends, outlets, etc. as required complete all as specified and as directed. |
| 22 | Supply & Fixing mild Steel work in hollow square/rectangular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S. 4923 -1997 (Reaffirmed 2009)grade Yst.-310 complete all as specified and directed. |
| 23 | Supply & Fixing plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment cofirming to Fe 410 -W (Gde- E- 250) quality-A complete all as specified and directed. |
| 24 | M&L for Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, orscrewed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, longbut length of bolt exc 5cm but n exc 10cm long complete all as directed. |
| 25 | M&L for pre-painted hot dip aluminium-zinc alloy metallic coated corrugated steel sheet, any pattern corresponding to IS15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ 150, 0.50mm thick of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed |
| 26 | M&L for hot dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ 150, 0.50mm thick of an approved colour and having yield strength of 550MPa as in ridge/valley/gutter/eaves boardings fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed. |
| 27 | S & F Aluminium powder coated door shutter single / double leaf, side huge typeon floor door spring (to be paid sepratly), 44.45 mm wide (two panels) fabricated having hanging and meetingstyle 85.00 mm X 44.45 mm x 3mm thick , top rail 83.50 mmx44.45mmx 3mm thick, middle rail 150 mm x 44.45 mm x 2.65 mm thick andbottom rail 150 mm x 44.45 mm x 2.20 mm thick and including jointing cleats, aluminium anodised snap beading, screws, aluminium anodised fittings such as pair of ‘D’ type handle 250 mm long(decorative type), tower bolts 150mm long 1 Nos for each leaf,aluminum beading, PVC packing,locking arrangement with mort ice lock 6 lever and necessary fittings & fixtures complete all as specified and directed by Engineer – in - Charge. |
| 28 | M&L for 50 mm thick Cement concrete type C-1, 1:3:6 (using 20 mm graded stone aggregates) as in plinth protection etc, finishing cement concrete surface even and smooth with out using extra cement including making joints with hot bitumastic mix in proportion of bitumen and sand 1:2 complete as specified & directed. |
| 29 | M& L for hardcore of gauge n exc. 63mm, using broken stone or boulders deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as directed. . |
| 30 | M& L forPCC 1:3:6type C1 using 20 mmgraded aggregate as in foundation filling ,mass concrete and sub base floor. Complete all as dirceted. |
| 31 | M&L Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade any shape and size confirming to IS 15658-2006 with grey cement andpigments.th approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ layingof inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete. |
| 32 | Dismantling fencing wire mesh, any type complete all as dirceted. |
| 33 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion andmaking good disturbed natural ground complete all as dirceted. |
| 34 | Excavating soft/loose soil in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning,filling in and ramming earth or broken rubble mixed with earth around, in layers notexceeding 25 cm, complete all as dirceted. |
| 35 | S& F Mild steelhand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as dircted. |
| 36 | M&L for TMT bars Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for strengthening the chain link fencing complete all as dirceted. |
| 37 | Supply only chain link fencing MS galvanised fencing including lines wires, any mesh, size and type to standards, rails, straining bolts, etc. including provision of binding wire all as specified and directed |
| 38 | Fixing only chain linkMS galvanised fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire. complete all as directed. |
| 39 | S&F 12mm dia mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long . |
| 40 | M&L for preparation of new or previously un treated steelSurfaces of any description, n.exc 10cm in width or girth when unconnected with other painting or when painted in a different tint and applying two coats of synthetic enamel paint over a coat of red oxide complete all as dirceted. |
| 41 | M&L for preparation of new or previously steel surfaces of any description, over 10 cm width or girth, not otherwise described and evenly applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 42 | Cutting openings through walls built in cement mortar for door, window and other openings or enlarging existing openings, etc., or cutting out defective masonry for underpinning including providing, fixing and removing, shoring, cleaning and stacking stone and removing surplus to storeand rubbish off the premises |
| 43 | Cutting into old masonry built in cement mortarto form toothings for and bonding in new brick or stone work including making good in cement mortar of the same mix. |
| 44 | M&L for Providing precast cement concrete in win- dow or door cills, lintels, bressumers, steps,quoin blocks (for use with masonry),string courses, copings. kneelers, apex stones, pier caps,columns, posts,boundary pillars, bed plates, pintle blocks, ancho-rage blocks, bonders (for stone walling). corbels, brackets,etc. (of any section indicated), with plain fair faces, including chamfers, weatherings, throat- ing etc. and setting in mortar complete with joints to match . |
| 45 | M&L for machine cut kota stone slab flooring 20-25mm thick over and including 15 mm thick screed bed in CM !:6 laid and jointed wiith grey cement slurry mixed with pigment to matxch the shade of the slab including rubbing and polishing complete all as specified and directed |
| 46 | M&L for kota stone slab 20-25mm thick I riser of steps, skirting, dado and pillar over and including10 mm thick rendering in CM 1:4and jointed with grey cement mixed with pigment to matxch the shade of the slab including rubbing and polishing complete all as specified and directed |
| 47 | Dismantling structural steel work including doors, gates but excluding framed truss etc. compleet all as dirceted. |
| 48 | Surface excavation30cm deep and getting out in soft/loose soil complete all as specified and directed. |
| 49 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth for foundation getting out soft loose soil complete all as specified and directed by Engr-in-Charge. |
| 50 | Material & Labour for plain cement concrete (1:4:8), type D-2, (using 40mm graded stoneaggregates)in foundations, filling, mass concrete etccomplete all as specified and directed. |
| 51 | Material & Labour for plain cement concrete (1:2:4), type B-2, (using 40mm graded stoneaggregate)in foundations, filling, mass concrete etccomplete all as specified and directed. |
| 52 | Supply & Fixing mild Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S. 4923 -1997 (Reaffirmed 2009)grade Yst.-310 complete all as specified and directed. |
| 53 | S&F forrolled mild steel Plates (plain or chequred) channels, square cut or notched (ordinary and counter sunk) forming holes, with out any attachmentconforming to Fe:410-W(Gde-E-250) quality-A complete all as specified and directed. |
| 54 | Returning filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm of soft loose soil. |
| 55 | Removing excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. |
| 56 | M&L for Providing, cement concrete type B-1, 1:2:4 (using 20mm graded stone aggegate) in kerbs,stops, rounded or chamfered on edges of carriageway including necessary formwork. |
| 57 | M&L Prepration of newly plastered surface of wall and applying two coat of cement base paint over a coat of primer complete. |
| 58 | M & L for Forming embankments includingraising (or lowering) earth,spreading in layers n exc. 30 cm thick;watering, ramming/rolling andfinishing to required size, shape,etc., n exc. 1.5m high from base complete all as specified. |
| 59 | M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directd by engr-in-Charge |
| 60 | M&L for providing reinforced cement concrete M-25 (Design Mix) using 20mm nominal size graded crushed stone aggregate as in beams, cantilevers, bressumers,lintels over 1.5m span etc.complete all as specified and directed. |
| 61 | M&L for providing reinforced cement concrete M-25 (Design Mix) using 20mm nominal size graded crushed stone aggregate as in chajjas comlpete all as specified and directed. |
| 62 | M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels. Cantilevers, shelves including supports, overhangs, etc also splays between floor and beam etc for rough finished flat surfaces of cocrete complete all as specified and as directed. |
| 63 | M&L for formwork to chullah hoods, chajjas, troughs and similar items including edges for rough finished flat surfaces of concrete complete. |
| 64 | M&L Antitermite treatmanet treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as directed. |
| 65 | M&L Antitermite treatmanet Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as dirceted. |
| 66 | M&L TMTbars 10mm dia and over, cut to length, bent to shaperequired, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia orsecuring with clips complete all as dirceted. |
| 67 | All as per Item No 66.00 above, 6 to 8mm diacomplete all as dirceted. |
| 68 | All as per Item above, but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as dirceted. |
| 69 | M &L for Pressed steel frames (105 x 60) for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed complete all as directed. |
| 70 | S&F Steel windows with side hung shutters including box type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as dirceted. |
| 71 | S&F 30 mm thick, Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides & fixed to chowkats complete all as specified & directed. |
| 72 | S&F4mm thick sheet glass, ordinary quality and glazing with oil putty in squares n exc 0.5sq. m in each panecomplete all as specified and as directed. |
| 73 | S&F Steel windows with side hung shutters including box type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded. |
| 74 | S&F 30 mm thick, Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides & fixed to chowkats complete all as specified & directed. |
| 75 | S&F4mm thick sheet glass, ordinary quality and glazing with oil putty in squares n exc 0.5sq. m in each panecomplete all as specified and as directed. |
| 76 | S&F framed work such as griils, grating, angle iron door frames etc., with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, barred iron doors, laders, framed balusters, walk ways, railings frame work of water tanks and similar work conforming to Fe-290. Gde E-165 complete all as specified & as directed. |
| 77 | S&F 150 mm size, aluminium anodised , barrel tower bolts of extruded section & fixed completeall as specified and as directed. |
| 78 | S&F 250mm length of bolt, aluminium alloy, anodized,sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified & as directed. |
| 79 | S&F 150mm size aluminium handles, cast type, anodized and fixed complete all as specified & as directed. |
| 80 | M&L preparing new wood & wood based surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified & directed. |
| 81 | M&L for 75 mm thick Cement concrete type C-2, 1:3:6 (using 40 mm graded stone aggregates) as in plinth protection etc, finishing cement concrete surface even and smooth with out using extra cement including making joints with hot bitumastic mix in proportion of bitumen and sand 1:2 complete as specified & directed. |
| 82 | Taking down aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as directed. |
| 83 | M&L for Point wiring complete as specified with 1100 volt grade 1.5 sq.mm. (nominal area) single core PVC insulated unsheathed cable multi-stranded copper conductor drawn through and including PVC casing and capping of suitable size but not less than 20mm, with all fittings, fixed on wall/ceiling /floor including modular box suitable for housing modular pattern switches/ sockets/ regulators etc.and duly earthed with same cable as for wiring above but green in colour as continuous earthing wire complete all as specified & directed for :-(a) One light /Fan /Ex Fan point controlled by one, one way switch(b) One socket outlet 3 or 5 Pin, 6 Amp on independent board |
| 84 | All as per Ser item No 83.00 above but with 1.5 sqmm copper cable in and including PVC casing and capping complete all as specified and as directed for One socket outlet 3 or 5 Pin, 6 Amp on same board. |
| 85 | All as per Ser item No 83.00 above but with 2.5 sqmm copper cable in and including PVC casing and capping complete all as specified and as directed for socket outlet 3 or 6 pin 15 Amps. |
| 86 | S&F modular switch 6 Amp one way 1 module 230 V AC complete all as specified and directed. |
| 87 | S&F modular switch 16 Amp one way 1 module230 V AC complete all as specified and directed. |
| 88 | S&F modular socket outlet 6Amp 2 module intel multi socket for all pins 230 V AC complete all as specified and directed. |
| 89 | S&F modular socket outlet 16 Amp 2 module and 6/16 Amp heavy duty 230 V AC complete all as specified and directed. |
| 90 | S&F modular ceiling fan regulator, electronic step type, 5 speed AC 230 volts, 2 module complete all as specified and directed. |
| 91 | S&F 3 module Metal Flush Box including white cover plate with frame for fixing of modular switeches/sockets etc. complete all as specified and directed by Engineer-in-charge. |
| 92 | S&F 4 module Metal Flush Box including white cover plate with frame for fixing of modular switeches/sockets etc. complete all as specified and directed by Engineer-in-charge. |
| 93 | S&F 6 module Metal Flush Box including white cover plate with frame for fixing of modular switeches/sockets etc. complete all as specified and directed by Engineer-in-charge. |
| 94 | S&F 8 module Metal Flush Box including white cover plate with frame for fixing of modular switeches/sockets etc. complete all as specified and directed by Engineer-in-charge. |
| 95 | S&F ceiling rose, three terminal, PVC/polycarbonate, isolated body, ISI markedcomplete all as specified and as directed. |
| 96 | S&F LED Tube lights fitting 1 x 18/20 Watt, 4 feet ,220V AC decorative box type with driver, holder including fitting fixed on wall/ceiling and connecting up complete with 3 core flexible cable white of suitable size and making necessary connection complete all as specified and directed. |
| 97 | Fixing only serviceable LED Tube lights fitting 1 x 18/20 Watt, 4 feet ,220V AC obtained from taking down. |
| 98 | S&F Supply and Fixing of Flameproof cum Waterproof LED Bulk Head light fitting of 15W, IP66 protection of Cast Aluminum alloy material and Heat and Impact resistance toughen \"A\" clear glass having Anti corrosive epoxy powder coated finish complete with all accessories pre wired and including connecting up with three core flexible copper conductor cable with suitable size including taking down old unsv light fitting all as specified and directed. |
| 99 | S&F LED building security light fitting 1 x 35 Watt new generation energy saving and environmental friendly long life LED street light made up of pressure diecast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP65 protectionincl mounting bracket of suitable size and connection complete all as specified and directed. |
| 100 | Taking down carefully old unserviceable ceiling fans / Exhaust fans complete, removing its blade and deposit to the MES Store yard/Keep in safe custody incluidng refixing after necessary repair works. |
| 101 | Over hauling of ceiling fan of any sweep/ make i.e. opening of fan and cleaning ball bearing, filling grease/ oil and changing of u/s cotter pin, nut, screw, check nuts and bolts as required incl. cleaning of body, blades, down rods, canopies etc and re-assembling andpaintingcomplete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust complete all as directed. |
| 102 | Hanging only ceiling fan any make/ sweep and connecting up with existing electric circuit complete received from MES Store Yard all as specified and directed. |
| 103 | S&F ceiling fans 1200 mm sweep, AC 230 V complete with blades, down rods andconnected accessories, Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with (BLDC) brushless direct current motor and connection complete all as specified and directed. |
| 104 | S&F Exhaust fans made of sturdy Engineering plastic/Metal complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm and connecting up including louvers including making necessary opening on stone /brick masonry wall of suitable size, finishing it properly and making good with matching colour with the surroundings provision of cable 3 core ofof suitable size from ceiling rose to fan complete all as specified and as directed. |
| 105 | Supply & fixPrewired Distribution Board factory made sheet metal enclosure double door distribution board class IP-43 IK 09 with 200 Amp rated copper bus bar 240 Volts 8 waysingle pole and neutral link, complete all as specified and as directed. |
| 106 | S&F MCB single pole and neutral (SP&N) 40 Amp 240 volts 10 KA \"C\" series with all incoming/outgoing connections with proper size lugs including taking down old unserviceable, complete all as specified and directed. |
| 107 | S&F MCB single pole (SP) 6 to 32 Amp 240 Volts 10 KA \"C\" series with all incoming/outgoing connection with proper size lugs including taking down old unserviceable complete all as specified and directed. |
| 108 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 2 core, complete including taking down old u/s service wire. |
| 109 | M&L for brick protection over cables inside the trench by using common burnt clay building bricks,sub-class\"B\" laid dry and flat and width wise along the axis of the trench complete all as specified and as directed by Engineer-in-Charge. |
| 110 | M&L for sand cushioning in cable trenches over & under the cables, with river washed coarse sand, as per standard practice with proper compaction complet all as specified anddirected by Engr-in-Charge. (Punned thickness shall be considered for payment). |
| 111 | M&L for light grade galvanized pipe ISI marked with all fitting ISI marked, laid in trenches, under road or fixing on wall/pole/ crossing nallahetc of bore40 mm complete all as specified and as directed . |
| 112 | Material and labour for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to galvanized iron earth lead wire 4mm dia, (main earthing lead ) by means of galvanized bolts, nuts and washers all as shown in electrical plate no 5 of MES Schedule Part-I (1991) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe light grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia light grade for watering pipe with funnel & wire meshincluding necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick pre-cast RCC cover in 1 : 2 : 4 type B1 with 3 Nos 8 mm dia TMT bars both ways completeall as specified & directed. |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail